Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
42-015 (3)
BP-2023-0238 242 WEST FARMS RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-015-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0238 PERMISSION IS HEREBY GRANTED TO: Project# WOOD STOVE 2023 Contractor: License: Est. Cost: 15565 CORY MCGILL 107658 Const.Class: Exp.Date: 05/25/2023 Use Group: Owner: ELBIN VARGAS SUZANNE D& Lot Size (sq.ft.) Zoning: WSP Applicant: CORY MCGILL DBA DONE RIGHT CHIMNEY Applicant Address Phone: Insurance: PO BOX 1054 (413)340-1399 WCV 01525601 WILLIAMSBURG, MA 01096 ISSUED ON: 02/27/2023 TO PERFORM THE FOLLOWING WORK: CHIMNEY RELINE AND WOOD STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signatu re: 4 )2 3s) , . AD1T , Fees Paid: S65.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner r` f •- -The Commonwealth of Massachusetts FEB 2 1 FOR Board of Building Regulations and Standards 2L'23 MIJNICI'ALITY Massachusetts State Building Code, 780 CMR USE Building Permit Application To Construct,Repair,Renovate Qr en o,'i h a Rdvised Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building Permit N r: 8/P• 3- 2. '5/ Date Applied: a (1<055 Z-77260 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 242 West Farms Road, Northampton 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Elbin Vargas Northampton, MA 01062 Name(Print) City,State,ZIP 242 West Farms Road (413) 923-2780 elbinvargas123@gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) 0 Addition 0 Demolition 0 AccessoryBldg.0 Number of Units Other ® Specify: Chimney Reline,Metal Chimney ginstall.Wood stove install Brief Description of Proposed Work2: Level 2 Inspection completed 09/12/2022. To reline existing chimney to oil burner.To install Class A chimney through basement foundation,up the side of the house to a height that satisfies all manufacturers'specifications,Codes,and Standards.To install(1)Regency F2500 wood stove,venting into new Class A Chimney. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 15,565.08 1. Building Permit Fee: $ Indicate how fee is determined: 2. Electrical $ ❑Standard City/Town Application Fee ❑Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $Q Check No. 33 1 Check Amount: u 442 Cash Amount: 6. Total Project Cost: $ 15 565.08 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-107568 05/25/2023 Cory McGill License Number Expiration Date Name of CSL Holder List CSL Type(see below) U P.O. Box 1054 No.and Street Type Description Williamsburg, MA 01096 U Unrestricted(Buildings up to 35,000 Cu.ft.) R Restricted l&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances (413)340-1399 ContactDoneRight@gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) #178722 08/27/2024 Cory McGill HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name P.O. Box 1054 ContactDoneRight@gmail.com No.and Street Email address Williamsburg, MA 01096 (413)340-1399 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Cory McGill to act on ry ehalf, n all matters relative to work authorized by this building permit application. 3 Print Owner's Name(E romc Signature) ate SECTION 7b: OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true d accurate to the best of my knowledge and understanding. Cory McGill 001)3)r I,),3 Print Owner's or Authori Ag is Nam (Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts . Department of Industrial Accidents = Office of Investigations ji :Nei; = 1 Congress Street,Suite 100 ".�� Boston,MA 02114-2017 TWO WWW.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Done Right Chimney Address:P.O. Box 1054,45 Main Street,Unit B City/State/Zip:Williamsburg,MA 01096 Phone#:(413)340-1399 Are you an employer?Check the appropriate box: Business Type(required): OM I am a employer with 4 employees(full and/ 5. ©Retail or part-time).* 6. ❑Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(incl.real estate,auto,etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. El Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.❑Manufacturing no employees. [No workers' comp.insurance required]** II.❑Health Care 4.❑ We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp.insurance req.] 12.0 Other Services:Chimney&Hearth *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:Atlantic Charter Insurance Company Insurer's Address:45 Main Street,Unit B City/State/Zip: Williamsburg,MA 01096 Policy#or Self-ins. Lic.# WCV 01525601 Expiration Date:06/28/2023 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify,under the pains and penalties of perjuty that the information provided above is true and correct. Signature: SCOL M(Y) Date: 0a0a312o93 Phone#:(413) 340-1399 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.mass.gov/dia h� ecf yi Selkirk Chimney Systems (USA Only - See separate instructions for Canada) Sheet GS Installation Instructions Covering -General Installation Instructions & Owner's Maintenance Guide A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS CHIMNEY BE IN- A WARNING STALLED ONLY IN ACCORDANCE WITH Failure to follow these Installation Instructions could THESE INSTRUCTIONS. cause FIRE,CARBON MONOXIDE POISONING,OR DEATH.If you are unsure of Installation requirements, call the SELKIRK CHIMNEY SYSTEMS-MODELS, PART NAMES AND Phone Number listed on the back of these instructions. NUMBERS Selkirk Chimney Systems(SCS)consist of the following Models-UT(Ultra fully enclosed at 2 inches minimum AIR SPACE clearance to combustibles, Temp),ST(Sure Temp),GT(Galva Temp),SG Plus and SSII. including framing lumber,drywall,plaster,plywood and other building mate- The complete part number is prefixed with the ID size, in inches,followed rials classed as combustible. For support framing,see table on back page. by one or two letters identifying the system to which it belongs, followed AIR SPACE ONLY by the actual part identifier. The minimum clearance to Selkirk Chimney System pipe means AIR SPACE All accessory parts for the Selkirk Chimney System(all models)include a ONLY.The 2 inch clearance to pipe,and the spaces around supports must not letter"T"in the prefix and may be used with all Models unless otherwise be filled with any type of insulation.In attics with blown-in or batt insulation, indicated. the chimney must either be fully enclosed or an Attic Insulation Shield must All Model UT,ST and GT chimney sections(straight lengths,tees,elbows) be used to create and maintain the proper minimum airspace. contain the letters"UT", "ST",and"GT", respectively in the prefix. SIZES AND APPLICATIONS All Model SG Plus chimney sections (straight lengths, tees, elbows)con- The Selkirk Chimney System is made in 5",6",7",8",10",12",and 14"sizes. tain the letters"GP"in the prefix. The four smaller sizes conform to the current edition of UL-103 Standard Type Fig. 1,2,and 3 show the names and locations of commonly used chimney HT requirements.All seven sizes comply fully with the requirements of the 9th parts. These figures use only the last portion of the part number. The Edition of UL Standard 103. Chimneys installed in accordance with these complete part number is prefixed with I.D.size,followed by chimney model instructions will comply with national safety standards such as NFPA 31,54 and part number. and 211.The Selkirk Chimney System may be used for gas,wood and liquid fuel fired stoves,fireplace stoves,central furnaces,floor furnaces,steam and hot water boilers, unit heaters and water heaters. It may also be used for IMPORTANT:Chimney sizes 5",6",7"and 8"are Type HT and carry a"T" masonry fireplaces. in the part number. Larger sizes use an"S"in the part number. These Selkirk Chimney Systems are designed for gravity venting only.They FOR EXAMPLE are usable on any appliance having a power burner(such as oil furnace)if that Model UT appliance operates with neutral or negative draft at its outlet. Inside Diameter I 36"Pipe Length Non-residential appliances which may cause positive pressure in the chimney should use a Selkirk Model PS or IPS system. The Selkirk Chimney Systems,sizes 10", 12",14",are ideal for venting gas (natural and LP),#2 oil,and open front wood burning appliances. Model ST Inside Diameter I Insulated Tee DETAIL INSTRUCTION SHEETS Details for the installation of all chimney parts must be observed by refer- All Models ring to other instructions as follows: Inside Diameter I Wall Support Kit Finish or Ceiling Supports*,Connectors S-1 `7T-WSK� Fire Stops,Attic Insulation Shields" S-2 Round Top*,Flashing,Spark Arrester S-3 NOTE:Use only Selkirk Chimney System Listed components Roof Support Package*,Anchor Plate* S-4 and accessories. Do not use pipe by itself or attempt to fabricate Insulated Tee*,Wall Support Kit* S-5 your own support or accessories. Insulated Elbow*, Interior Resupport* S-5 CAUTION:IF YOU ARE BURNING COAL Firestop/Joist Shield* S-7 Some types of coal in certain designs of stoves may, in rare instances, Support Box* S-9 cause corrosion of the inner parts of the Selkirk Chimney System.Inspect and *If you are installing any of these parts in packages marked*,you should clean your chimney frequently to keep it free of coal,ash and soot deposits. receive the proper instructions in the package. You may also request a Also see"Sizes and Applications"section.If damage to the flue is observed, complete set of instructions from your dealer.This sheet of general instruc- contact your Selkirk dealer or Selkirk Customer Service(1-800-992-VENT) tions is furnished with all UL listed chimney supports. It covers important with a description of your chimney problem. safety precautions in the installation, operation and maintenance of your The Selkirk Chimney System is not recommended if you are burning ocean appliance and chimney. Anyone installing a chimney should review this driftwood.The salt in this wood may cause product failure. sheet as well as those furnished with the other parts of the chimney system.Selkirk chimney parts LISTED and produced under the Factory In- MINIMUM CLEARANCE spection and Follow-Up program of Underwriters'Laboratories,Inc.carry the Where installed within buildings,the Selkirk Chimney System maybe LISTING MARK illustrated here. SPECIAL WARNING ON CELLULOSE INSULATION Cellulose insulation in direct contact with a hot chimney can ignite and smolder,and can set fire to ordinary wood framing L I S T E materials. The AIR SPACE ONLY precaution applies to all blown-in or loose fill insulations, but is especially applicable to cellulose insulation,which may be made from old newspapers or other cellulose materials.The Attic Insulation Shield or a suitable enclosure with appropriate fire stops must be used to keep all insulation the proper distance away from the chimney. J..SELKIRK, 3050 Corporate Exchange Blvd. SE, Grand Rapids, MI 49512 1-800-433-6341 SELKIRK CORPORATION Round Top(CT) 41.Li) t —Round Top(CT) ChimneyPipe Storm Collar(SC)— Flashing(AF)or(TF) /Roof Shield with TF • Storm Collar(SC) ��, i Il , '4�\ Interior Resupport(IR) V / Full Enclosure or Attic IAttic Insulation shield F*44%' Area Locking Band(LB) �, �' or Screws Chimney Pipe Insulated Elbow(EL) I` ..Firestop/Joist Shield(JS) Below Framing 411111110 MAXIMUM OFFSET Maximum inclined Length: IAttic Insulation Shield(AIS) AT30° _96"unless resupported at ANGLE1 48"intervals /� Fire Stop/Joist Shield(JS)—\ Opening Framed On 30° —Full Enclosure, All Four Sides 2"Minimum Air Space Clearance iii (.... Insulated Elbow(EL) Locking Band(LB) or Screws CHIMNEY MUST BE 1111 1, ENCLOSED -----Finish Support(FSP)or Ceiling Support(CSP) Chimney Pipe FIG 3 THIRTY DEGREE OFFSET WITH ENCLOSURE AT 2" Finish Support(FSP)or CLEARANCE(MAXIMUM OF TWO SEPARATE OFFSETS PER SYSTEM) Ceiling Support(CSP) -4 / WHEN INSTALLING YOUR CHIMNEY AND j \/� //// WOODBURNING STOVE OR Dripless Smoke Pipe Adapter� % FIREPLACE SYSTEM,REMEMBER... (DSA)or(DSAC) SAFETY FIRST 6",7",8"only or 5"-14"Chimney You may well have a basic knowledge of carpentry and the use of hand Pipe Adapter(CPA) tools. However it is important that you also review the rules of safety on FIG1 VERTICAL CHIMNEY THROUGH ONE the following pages. If you have any doubt about your ability to complete STORYANDATTIC your installation in a workmanlike manner,you should arrange for a profes- sional installation. RULES FOR SAFETY DURING INSTALLATION 1. Read all installation sheets. Look for them in the cartons,or ask your dealer for a complete set or download from www.Selkirkinc.com. Keep the � - Wall Band(WB) Every 8 Feet If instructions handy and save them for future reference. Combustible Wall— 2. Check your local building or fire code for all requirements affecting the Not Enclosedfuel-burning appliance and its chimney. Use Locking Bands 3.Obtain a building permit for both the appliance and the chimney.Contact (LB)on All Joints local building or fire officials about restrictions and installation inspection in your area. Max Chimney Height 4.Be very careful around electrical wiring and be sure it is secured at least 50 Feet 5",6",7"8"Size 2 inches away from any part of the chimney. If wiring must be relocated, 40 Feet 10", 12", 14"Size hire a professional electrician. z° 5.Be sure that ladders are in good condition and always rest on a level firm Min.Clearance --mum To Combustibles Full Enclosure surface. iI Recommended. 6. Wear cut resistant gloves when handling sheet metal parts with sharp , Both Indoors edges. and Outdoors 7. Be sure that electrically powered tools are properly grounded. Min.Thru Wall 4-1/2" 1'1-- CHIMNEY HEIGHT AND SIZE Selkirk The suns onta " eto Chart" o yu n ph ex Chimney Section Insulated Tee(IT) combinationtr of lengthc increments. A chimney for oneo or more gas appli- ances must conform to size anda Sel heightc recommendationss ca intheick"Selkirkt Gas Wall Thimble �, Wall Support Kit(WSK) Ventes andin Chimneyctio Sizing Handbook.in "Heights above the roof as givene inact the (IWT)Shield miembo� next paragraph are minimum; greater heights may be needed for reasons given. Wall Thimble(IWT)/ Capped Cleanout and Before beginning installation of the chimney,be sure that the selected size Face Plate Retainers is adequate for the appliance and the selected height of the Chimney Lag Screws Brace Round Top termination is high enough to conform to building code require- Into Structure I ments. Chimneys are required to extend at least 3 feet above the highest point where they pass through the roof of a building,and at least two feet I Pad higher than any portion of a building within 10 feet.(National Fire Protection Association Standards Nos.31, 54,and 211.)See Fig.4. FIG 2 INSULATED TEETHROUGH COMBUSTIBLE WALL INSTALLATION INSTRUCTIONS Phone:888-900-8106 FOR BEST-Flex Models "L", "H", "S", & "E„ Fax:888 392 4432 MN STAINLESS STEEL CHIMNEY LINERS Web:www.NewEnglandChimneySupply.com - Jii*�' 34 Commerce Street,Williston VT 05495 0BEST-Flex Models iiLI, iiH,, iiQ77 o "E7! HEST 7 7 FLEX New England Supply PRODUCTS STAINLESS STEEL CHIMNEY LINERS BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,VT. The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys.BEST-Flex liners are used to vent the gases and by-products produced by appliances that burn oil,gas,or solid fuels. All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance. The installer must contact the local building and fire code officials for a variety of reasons: • The installation may require special inspection requirements. • Building permits may be required before installation. • Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and Fire Bureau's have precedence over national codes). For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not followed BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories. • In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys. • In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys. PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS • The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction. Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation.BEST-Flex can be used to vent wood,wood pellet,coal,non- condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"to 12"diameters (13"above is not listed)to cover a wide range of requirements found in the field today. • The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked and crimped to produce a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimneys and can be factory ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be field ovalized. The corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stresses on the system. • BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635 standards for chimney exteriors with zero clearance to combustibles. • BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 percent or lower. MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION: Liner Model-"L","H","S",&"E" • TT/TB-Two piece or one piece tee �* TEC-Tee Cap EA/EF-15°-90°elbow C/CC-Coupler a ; .; Screws/Rivets OPTION A ," OPTION B TP-Top Plate ""''x TPCC-Liner Capit* TC-Top Clamp . "Or OR TPC-Top Plate OR SC-Storm Collar t°CL-Liner Cap(square/round) �=' INSULATION MATERIALS REQUIRED(if applicable) Part# Description LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket LM Liner Mesh Protective Wire Mesh Sleeve FT(2",3") Aluminum Foil Tape CO =� LMC(Iarge/small) Mesh Clamp ' BMIX BEST Mix Phone:888-900-8106 j�(� Fax:888-392-4432 ILA �`Jl Web:www.NewEnglandChimneySupply.com New England Supply 34 Commerce Street,Williston VT 05495 1.)CHIMNEY PREPARATION&INITIAL INSPECTION Before any liner can be installed the existing chimney must meet proper construction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material.If the chimney is constructed on the outside of the structure, 1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with all local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full inspection must be done to determine if the chimney is structurally sound.If the existing system is found not to be in compliance with applicable building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring the chimney or vent into compliance with the applicable code and/or manufacturer's instructions. Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original chimney or vent in which it is installed. CHIMNEY CONNECTORS AND VENT CONNECTORS 2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER • Any heating appliance connected to the lining system must not Mainamm na dolor. system A.himim„m3sb.(eomm)th brick masonry wallframedinto to beck and combustibles 2 n.(51 cone) t:l I,y,im,0 cywyp from coy wal with a minimum of 12 in.(305 mm)bKM C napareli0n have a flue outlet size larger than the liner area at its smallest � !S+C of bockp5mmi from c:adiowlicambusfiClay,,ue nersand homnoyP 315. _ t of molt Standard SceciISrnln for Clayr l shall run Pots.or equivalent). point,unless a qualified person has sized the liner to suit the -1 l minimum 1,m n6 coil wall thldiness.shin con from outer sUdace T of brck wall to.but not beyond.the aver eoeboo of chimney sue appliance Goer and steal be firmly cemented in pace, aymney'li:; cr ce, • For sizing a liner used for gas and oil burning appliances refer Clearance 12 N.(305 mm) to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the tw � " Mam,yea appliance manufacturer's instructions.Liners that are incorrectly le contoollblo wwrvned to aFaa 21, sized for the appliance can lead to poor draft,excessive condensation,and creosote build-up inside the lining system, kamamen carnna,mamma„m System B.5olid.insulated.listed factory-built chimney length of the some masonry to sheet steal support.and _ Mnnnm inside diameter as the chimney connector and having l In. Please call New England Supply Inc.should you have any combust.. ,25mmormereoltnsnletnneelhamiiimum9,n.(229mm) 8In(22B mm) chimney length and Nonxlu,k : air space between the oaten well of the chin questions about sizing a liner. fclor/WO m,;,°�,, � Chow, cp,,,CL11„,as ct11^ne,'toyth c connector The'nner end of the chimney length shall be Hush with the • For sizing a liner used for solid fuel burning appliances the cross I)- Granary cement a invaeet the masonry chineoot'.and shall be sealed to the flue section area of the liner shall not be less than the cross sectionaumvah moo and his the beck masonry daunt,.with annwale,.nolote wHua —� Use elemey refractory cemonl.Supports shall be securely listened to wail area of the appliance outlet collar.Unless specified bythe mr•pans to sederes nn al sides PP P I, Nrelsane Chimney = \ attemmrveae Fasteners between supports and the chimney length shall not appliance the cross section area of the flue shall not be more than 9N(229ma)mn le• N. t SONOM f�" penetrate the chimney liner. three(3)times the cross section area of the appliance outlet collar. ,q,211 Clearance.0 n.(229 mm) Solid fuel burning fireplace liners should be a minimum of one- Sheet Owl epporo twelfth(1/12)the square inches compared to the square inches of the fireplace opening.This one-twelfth(1/12)number can wnmraneesey asea,se to seal—i System C.Sheet steel chimney conrrecror.minimum 24 gauge)0.024 in. neat suppohe and eoeRa a e (0.61 mm)]In thickness,with a ventilated thimble.minimum vary based on height of the chimney along with other calculating 2,•61reml ee az T,earneto 24 gauge l0.024„.(061mm)),nthi kness.having nsnl„. factors.Call New England Supply Inc.if you have any questions. lit N '""'25 ) (25 min)air channels,separated Prom combusadas by a mimnwan of 6 in.(152 nil)of glass fiber Insulation.Opening shall be covered, and thimble supported with a sheet sleet support.minimum 24 gauge / (0.024 in.(0.61 lie in tnrl'ness. 3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO �� Supports chef be tea,*lesta ewe well surfaces en allsdes 11 aahmea 6 e and shall be seed to 61 and hold chimney.then.Fasteners used THE CHIMNEY C n52mm;�aaa Coo pre chimnoy section Shaine peneeate chimney Coo Hner. tan,0005led a, ,Car�nsu•ahon • The BEST-Flex Stainless Steel ChimneyLiner can be installed '�a"new aa`h "- Clea"'ca'6in('s2n9n) �,2acmnl, 0e 0c11 ch�mnay �' tin of meted0 NFFA211 inside the existing flue tile or the flue tile can be removed.It snmd ataal sheet aiw a,pparta is critical that the correct size liner will actually fit into the flue. Chimney construction and flue offsets may change the physical Vinman,amn, °to shoot gaol sucon,tasad System n.Solid-insulated,listed factory-built ei lne tergth with eninaide size of the interior of the chimney.It is best to test the smallest x t:kalee2N(51 non) dameter2 in.(51 rem)larger man the chimney connect.ano having k - Shoot steel I I m.(25 mm) more of insulation,serving as a pass.through bra single of the chimneyinterior before trying to install the chimneyr Sheetst ;MI lakmamdeanm2 kn.(61mm; all sheet steel&Oleey connector of minimum 24 gauge[0.024in. point rY g (0 61 mmil thickness,with a minimum 2 in.(51 rem)an space between the CChmney i_ u I to r2+nell)Mrepat0 outer wall of chimney section and conawsObes. liner.Lower a short piece of the correct size liner down the , to chimney S nimein„ngn of chimney„e,ton shalt oa,z tn.(aosmm,Chimney chimney to see if it will fit through,or a liner guide cone.If the section concentrie with end spaced,in(25 mm)away front connector by Cchi, I means Of sheet steel support plates on both ends Ot chimney section - chimney liner needs to be insulated extra space around the liner 'a°"h°"" a — Opening shall to cowed,and chimney sacker supported on both Wes with • MI' Chimney correctcr sheet steel supports of mintmum 24 n el or gauge tw ll and ceCoon/ sides Thickness. is required.If a round liner configuration will not fit the liner can be .. aw„aay, ' Supports dshaltbehmptofitasecurely dholdchedwwauaadacaaen rsusea Air apace 2 N.(51 mil 4� and chat!be sized to fit end hob chimney Confine.Fasteners used formed into an oval shape to fit at the factory. However an oval oeaan,rm,m 6nee14s•"�w rawamnay section shall not penetrate chimney(We lner. liner will change the cross section area and a larger liner may be "a °i° Peewee:21n(51 rnm) needed.Please call New England Supply Inc.with any questions. Note:All clearances and thicknesses are minimums;larger clearances and thicknesses are paneled. 4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER • Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the appliance. The liner length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately Six(6)inches to attach the crown and top hardware.Cut the liner to the desired length. • If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed band,or stainless steel screws(Male end down when applicable). • Attach the Tee Body to the liner with the affixed band,or stainless steel screws.If the liner needs to be insulated with a ceramic wool blanket,install the blanket at this point. Attach the Tee Cap to the Tee Body at this point. • Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the flue.Lower the liner 1---, 000\ E w b 1 PRODUCTS F2500 Wood Medium Stove Model F2500 i , , . Cordwood BTU's 78,000 BTU's i • Emissions(grams/hr)EPA Certified 1 gram/hr J Efficiency(EPA HHV)* 76% / "' l Z J . Efficiency(EPA LHV) 81% ( / t"R Flue Size 6"(152mm) US Biomass Tax Rebate Eligible Yes " '°. "US Biomass Tax Rebate eligibility is based on the HHV value being 1 1 greater than or equal to 75%. . sli+■ UNIT DIMENSIONS 1 t~ .,", . o IN ■ ILI; E le i F. I! II _ (r 1) E ... 20m ��omE [690mm] ll 1■ u 24-a" [630mm] 24' 6 4" [610mm] [163mm] I t_ lir°. I.—irilli".1.111111.1..Iftrin ■ tIIIII PI �� X 1111111 m M U �� I ill I.. 21 - [540mm] OUTSIDE AIR DIMENSIONS 1 - L Front F: fin. 1 ,► 1; II �► 4 +4-9/16"(115mm) rl p� .our 6-13/16"(173mm) l I Rear + Rear F2500 Wood Stove I 1 � REGENCY MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS BI E ease reaa the section below carefully as clearances depend on whether the airmate or A O the rear heat deflector is instated on the stove. , Measurements"From Unit"are from the top plate of the stove to a side wall or to a corner, D -♦- C and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority. F C Minimum ceiling height-83"(2108mm) NOTE:This clearance is also required for air space between the appliance and wall/ceiling. NOTE:Be aware that local Codes and Regulations may override some clearances listed in this manual. Check with your local inspector. ( Residential Installation"C"Vent (Single Wall) Unit From Unit From Corner From Flue Center-Line A B C D E F Medium F2500M with Airmate 16"(406mm) 8.5"(216mm) 7"(178mm) 28"(711mm) 15"(381 mm) 19" (483mm) with Rear Deflector 16"(406mm) 10.5"(267mm) 7"(178mm) 28"(711mm) 17"(432mm) 19" (483mm) Residential Close Clearance(To be installed with required pipe components) When the stove is installed as a close clearance residential unit,a listed double wall connector is required from the stove collar to the ceiling level. Unit I From Unit From Corner From Flue Center-Line A B C D E F Medium F2500M with Airmate 15"(381mm) 7"(178mm) 5"(127mm) 27"(686mm) 13.5"(343mm) 17' (432mm) with Rear Deflector 15"(381mm) 9"(229mm) 5"(127mm) 27"(686mm) 15.5"(394mm) 17" (432mm) Mobile Home Close Clearance(To be installed with required pipe components) "C"Vent single wall pipe is not approved for Mobile Home installations.(Refer to Mobile Home Instructions.) Unit From Unit From Corner From Flue Center-Line A B C D E F Medium F2500M with Airmate 15"(381mm) 7"(178mm) 5"(127mm) 27"(686mm) ( 13.5"(343mm) 17" (432mm) with Rear Deflector 15"(381mm) 9"(229mm) 5"(127mm) 27"(686mm) 15.5"(394mm) 17" (432mm) 2 I F2500 Wood Stove