Loading...
17091651B-Dennis Palmer CC, DWGS-3OVERHANG INFO HEEL HEIGHT GABLE STUDS 00-06-00 24 IN. OC END CUT RETURN PLUMB NO REQ. ENGINEERING JOBSITE REQ. LAYOUTS NONE 1 QUOTE LAYOUT CUTTING DH1 DH1 DATEBY SHIP TO 231 Main Street PO Box 289 Easthampton, MA 01027 Fleury LumberSOLD TO (413) 527-2693 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / 10/17/17 / /ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # FFKEDEF ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 17091651B Brian Tetreault Massachusetts / / / David Fagnand (413) 527-2693 PAGE 1 SPECIAL INSTRUCTIONS: DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG: Dennis Palmer BUILDING DEPARTMENT Roof Trusses JOB CATEGORY:Residential LOT #SUBDIV: DATE09/22/17 Northampton, MA Dennis Palmer David Fagnand 09/22/17 09/22/17 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5780 UFP Belchertown, LLC QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:16.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN T014.44 0.00 27-06-00 01-00-00 01-00-002 X 4 2 X 4 FINK 16 27-06-00 T01GE4.44 0.00 27-06-00 01-00-00 01-00-002 X 4 2 X 4 GABLE 2 27-06-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY:TITLE: ADDRESS: PHONE:DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL Quote is based on current design values at the time of quote (lumber, EWP, hardware, etc). Should any of these values change prior to completion of this project, reserves the right to adjust the sell price accordingly. UFP Belchertown, LLC QUOTE POLICY: QUOTE VALID FOR 7 DAYS. AFTER 7 DAYS, UFP RESERVES THE RIGHT TO REVIEW / ADJUST ALL PRICING. Sealed individual truss drawings are included in the pricing. Sealed layouts, stamped bracing diagrams are NOT included BUT can be provided for an additional charge. Job 17091651B Truss T01 Truss Type FINK Qty 16 Ply 1 221 Job Scheme Used Job Reference (optional) Run: 8.030 s Apr 8 2017 Print: 8.030 s Apr 8 2017 MiTek Industries, Inc. Fri Sep 22 09:25:19 2017 Page 1 Universal Forest Products, 5631 S. NC 62, Burlington, NC ID:TkWP33Dg?JY6Lgq?Mw2rrgydlUX-uIdN?TMgtqsJQgC72H3MkymeMYX0fKVvLaJobvyb7z_ Scale = 1:46.9 B1 T1 T1 W1 W2 W2 W1 B2HW1 HW112 3 4 5 6 7 10 9 8 4x6 3x4 4x6 3x4 1.5x3 3x4 1.5x3 4x6 15-8-11 5-7-010-5-5 10-5-5 17-0-11 6-7-7 27-6-0 10-5-5 -1-0-0 1-0-0 7-7-9 7-7-9 13-9-0 6-1-7 19-10-7 6-1-7 27-6-0 7-7-9 28-6-0 1-0-0 0-6-05-7-05-9-20-6-04.44 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-2], [6:0-0-0,0-1-2] LOADING (psf) TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 YES IRC2009/TPI2007 CSI. TC BC WB Matrix-MS 0.64 0.69 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.18 -0.47 0.09 0.08 (loc) 10-13 10-13 6 8-10 l/defl >999 >695 n/a >999 L/d 240 180 n/a 360 PLATES MT20 Weight: 92 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2, Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2=1167/0-5-8 (min. 0-1-13), 6=1167/0-5-8 (min. 0-1-13) Max Horz2=54(LC 8) Max Uplift2=-143(LC 6), 6=-143(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2298/715, 3-4=-1929/623, 4-5=-1929/623, 5-6=-2298/715 BOT CHORD 2-10=-585/2077, 9-10=-324/1446, 8-9=-324/1446, 6-8=-585/2077 WEBS 3-10=-590/257, 4-10=-152/625, 4-8=-152/625, 5-8=-590/257 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp C; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=143, 6=143. 7) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 17091651B Truss T01GE Truss Type GABLE Qty 2 Ply 1 221 Job Scheme Used Job Reference (optional) Run: 8.030 s Apr 8 2017 Print: 8.030 s Apr 8 2017 MiTek Industries, Inc. Fri Sep 22 09:25:19 2017 Page 1 Universal Forest Products, 5631 S. NC 62, Burlington, NC ID:TkWP33Dg?JY6Lgq?Mw2rrgydlUX-uIdN?TMgtqsJQgC72H3MkymnSYhrfLKvLaJobvyb7z_ Scale = 1:47.3 B1 T1 T1 B2 ST6ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 28 29 3x4 3x4 4x4 3x4 15-8-11 5-7-027-6-0 27-6-0 -1-0-0 1-0-0 13-9-0 13-9-0 27-6-0 13-9-0 28-6-0 1-0-0 0-6-05-7-05-9-20-6-04.44 12 LOADING (psf) TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 YES IRC2009/TPI2007 CSI. TC BC WB Matrix-S 0.13 0.06 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 180 80 n/a PLATES MT20 Weight: 105 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 27-6-0. (lb) - Max Horz2=51(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 2, 14, 22, 23, 24, 25, 26, 20, 19, 18, 17 except 27=287(LC 2), 16=287(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp C; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x3 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16. 11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard