Loading...
31A-263 (8) BP-2022-1603 63 DRYADS GREEN COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 31A-263-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1603 PERMISSION IS HEREBY GRANTED TO: Project# 2022 SOLAR Contractor: License: Est. Cost: 21000 EMPOWER ENERGY SOLUTIONS 019944 Const.Class: Exp.Date: 12/01/2023 Use Group: Owner: V TURNER KHAHTEE Lot Size (sq.ft.) Zoning: EU/URC Applicant: EMPOWER ENERGY SOLUTIONS Applicant Address Phone: Insurance: 30 OLD KINGS HWY S#1001 (475)221-2356 WC533SB2191Q011 DARIEN, CT 06820 ISSUED ON: 12/12/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 17 PANEL 6.8 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIO ATION OF ANY OF ITS RULES AND REGULATIONS. Signature: • .)4 • l I� II II Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of MassachusettsFOR•W Board of Building Regulations and Sta idar QEC 6 C MLfNICIPALTTY 2 Massachusetts State Building Code, 770 C Z2 USE Building Permit Application To Construct, Repair, Renovate,Or Demolish_ a ReVised Mar 2011 One-or Two-Family Dwelling `-;;77:7 ._;` This Section For Official Use Only ''''`' Building Permit Number: .6.� J•-/(103 Dat Applied: 4/ � �s� //& /Z-/2-ZOZz Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 operty Address: 1.2 Assessors Map& Parcel Numbers 0 DRYADS GRN NORTHAMPTON MA 01060 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1KOAg6'NNE NORTHAMPTON MA 01060 Name(Print) IV City,State,ZIP 60 DRYADS GRN (917)202-0574 khahtee@studiocreativeplay.org No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction ❑ Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Additio,i 0 Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work': Installation of a safe and code compliant,grid-tied PV solar system on an existing residential roof. 17 Panels/6.80kw(dc) SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) _ 1. Building $ 4,000 1. Building Permit Fee: $ Indicate how fee is determiined: 2.Electrical $ 17,000 ❑ Standard City/Town Application Fee ❑Total Project Cost3 (Item 6)x multiplier , x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: $ 6. Total Project Cost: $ 21,000 Check No. `'1t? Check Amount 1 Cash Amount: 0 Paid in Full 0 Outstanding Balance Due:_ _ SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 1 o99d4 12/2/2023 Lando Bates License Number Expiration Date Name of CSL Holder List CSL Type(see below) 51 Assabet Dr No.and Street Type Description Northborough,MA 01532-2600 U Unrestricted(Buildings up to 35,000 cu.ft.) City/Town,State,ZIP R Restricted 1&2 Family Dwelling h M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 774-249-1687 Lando.B@empowerenergy.co I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) Empower Energy Solution 198351 4/05/2024 HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 30 OLD KINGS HWY S SUITE 1001 operations@empowerenergy.co No.and Street Email address DARIEN ,CT 06820 (475)221-2356 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes . No . 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. 'tUtititt. V rsomeA. 11/22/2022 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. .. t,.4, 11/22/2022 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open H 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts p, -_ Department of Industrial Accidents 1 Congress Street,Suite 100 • �, i= Boston, MA 02114-2017 • ,,.,�v,, www mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE HIED WITH THE PER%II1TING ALTHORITY. A t!leant Information Please Print ,4 Name(Business'organtuttiomlndtvidual): Empower Energy Solutions Inc Address: 30 OLD KINGS HWY S#1001 City/State/Zip: DARIEN CT 06820-4551 Phone#: 475-221-2356 Are you an employer"Check the appropriate box: Type of project(required): 1.®I am a employer oath 10 empksyees(full and/or part-time).• 7. ❑New construction 201 am a sole prupnctLr or partnership and have no employees working for me in 8. O Remodeling any,capacity.(No worker'comp.insurance required.) 301 am a hurnovN ys insurance ncr doing all work myself.[No workers'comp_insurae required] 9. El Demolition 4.01 am a homeowner and will be hiring vontracton to conduct all work on my property. 1 will 10❑ Building addition enmity that all contntitiora either have worketx'compensation insurance or are sole 110 Electrical repairs or additions proprietors with no employees. 12.E Plumbing repairs or additions SO I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13 Roof repairs These sub-contractors have employers and have waiters'comp.insurance.: 14.®Other PV Solar Installation rc 6.0 We a a corporation and its officers have exercised their right of exemption per MGL e. 152,¢1(4),and we have no employees.[No workers'comp.insurance required] *Any applicant that check,box AI mesa also fill out the section below showing their workers'compensation policy information. Homeowner who submit this affidavit indicating they are doing all work and than hire outside contractors mint submit a new affidavit indicating such. ;Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have ctnpluvrrs. If the sub-contractos have employees.they must provide their sr otter;conip.policy nusnh:r s. I am an employer that is providing workers'compensation insurance for my employees. Bela is is the polity and job site information. Insurance Company Name: LM insurance Corporation____ �t•� , __— Policy#or Self-ins.Lie.#: WC533SB2191 Q011 Expirati Date:11/03/2022 A I I/5 ZQZ3 Job Site Address: 979 Bay Road CityiSta :Zi. .• y _ AO10t2 Attach a copy of the workers'compensation policy declaration page(showing the policy number and esp lion date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a tine up to• 1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a tine of up a S250.00 a day against the violator.A copy of this statement may be forwarded to the Office of investigations of the DIA fa insurance coverage verification. I do hereby certify under the pains and p nal ies of perjury that the information provided above is true and co Signature: s Date: June 04,2022 Phone#: (475)221-2356 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License q Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector S. Plumbing Inspector 6.Other Contact Person: Phone#: Ac�® DATE(MM/DDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 11/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME CT Brandy Jenkins WORLD INSURANCE ASSOCIATES LLC (A/C.No.Mit): (508)699-7511 FAX (A/C,N o): E-MAIL ADDRESS: brandyjenkins©worldinsurance.com 656 Shrewsbury Ave suite 200 INSURER(S)AFFORDING COVERAGE NAICft Tinton Falls _ NJ 07701 INSURERA: LM INS CORP 33600 INSURED INSURER B EMPOWER ENERGY SOLUTIONS INC INSURERC: INSURER D: 30 OLD KINGS HWY S 1001 INSURER E: _ - DARIEN CT 06820 INSURER F: COVERAGES CERTIFICATE NUMBER: 832847 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE iIADDL'SUBR, POLICY EFF POLICY EXP UNITS LTRINSD WVD POLICY NUMBER (MMIDD/YYYY) (MM/DD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCEDAMAGE TO RENTED $ CLAIMS-MADE I I OCCUR PREMISES Ea occurrence) $ MED EXP(Any one person) $ N/A PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY JEo LOC PRODUCTS-COMP/OP AGG _$ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS N/A BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY _ AUTOS ONLY (Per accident) _• $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ _ EXCESS LIAB CLAIMS-MADE i N/A AGGREGATE $ _ DED RETENTION$ 1 'WORKERS COMPENSATION PER OT-1- AND EMPLOYERS'LIABILITY X STATUTE ER Y/N ANYPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 500,000 A OFFICER/MEMBEREXCLUDED? N/A N/A I N/A WC533SB2191Q012 11/03/2022 11/03/2023 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 N/A DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Workers'Compensation benefits will be paid to Massachusetts employees only.Pursuant to Endorsement WC 20 03 06 B,no authorization is given to pay claims for benefits to employees in states other than Massachusetts if the insured hires,or has hired those employees outside of Massachusetts. This certificate of insurance shows the policy in force on the date that this certificate was issued(unless the expiration date on the above policy precedes the issue date of this certificate of insurance). The status of this coverage can be monitored daily by accessing the Proof of Coverage-Coverage Verification Search tool at www.mass.gov/Iwd/workers-compensation/investigations/. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Empower Energy Solutions Inc 10 Ramblewood Drive AUTHORIZED REPRESENTATIVE '. Rocky Hill NJ 06067 Daniel M.Crowley,CPCU,Vice President—Residual Market—WCRIBMA ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street - Suite 710 198351 04/05/2024 Boston, MA 02118 EMPOWER ENERGY SOLUTIONS INC ASIM HAFEEZ ' ` 30 OLD KINGS HWY S 4 �� r „�✓ ._'. Al:Oft, ,(4),C9, SUITE 1001 DARIEN, CT 06820 Undersecretary Not valid without signature Name Name: Lando Bates Address: 51 Assabet Drive Northborough, MA 01532 Licenses Eligible for Processing Building Licenses License Type Construction Supervisor License Status: Active License Number: CS-109944 Expiration Date 12/1/2023 Engineering Licenses Check Status License Type Hoisting Engineer License Status: Active License Number: HE-196329 Expiration Date 12/1/2021 Empower Energy Solutions Inc HOMEOWNERS AUTHORIZATION FORM Addendum to Contract I, Khahtee Turner (Print Full Legal Name) am the owner of the property located at address: 63 Dryads Grn Northampton MA 01060 (Print Full Address) I hereby authorize Empower Energy Solutions Inc to act as my Agent for the limited purpose of applying for and obtaining local building, electrical and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Customer Signature: Electronic Signature Accepted/Addendum to Contract Date: 09/02 /2022 Signature: PaidtL V rimitgA. Dnc ID' h57dr:hdch73fr65frc10754rdR3h037r17fcl15hda4cl LING CONSULTING r +'� 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com November 11, 2022 Empower Energy Solutions 30 Old Kings Highway South#1001 Darien, CT 06820-4551 Re: Engineering Services Turner Residence 63 Dryads Green, Northampton MA 6.800 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 Dimensional Lumber Framing members 16" and 22" on center. Roof Material: Metal and Slate Roofing Roof Slopes: 20 and 37 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures hi not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110%for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "S-5 and Solar Slate Installation Manuals". If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. System will be attached to the metal roofing material utilizing the patented S-5 connection. Installation of the connections shall be in accordance with the manufacturer's recommendations. 3. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 21/2", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 21/2" embedment will be adequate and will include a sufficient factor of safety. 4. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on centers. 5. Panel supports connections shall be staggered to distribute load to adjacent framing memt;ters. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly you r Q Scott E.Wyssli , PE MA License No. 505 • Is y tn :00 9pz E:Gioi ESS�flPIA� Signed 11/11/2022 LIN G NG AnBREAKER - - FUSE —e— MITCH EARTH GROUND —--— GEC INVERTER OUTPUT CURRENT(A) 25 EEC INVERTER BACKFEED(A) 31 ENGLE PH OVERHEAD LISP RATING(A)= 200 UMW SERVICE MAIN BREAKER RATING(Ap 200 ( MAX MAX BACKFEED(Ap 40 TIE IN: LST 900291111 ■ ■ • o48OLADECR AINCDON BOX (MSOLAREDOE*NEWER -UNWISE° (N)(17)1IA11WIMO.PEAK Duo RUC L8.-010400408W PV MODULES W14 SE00U8 -GROOMED (17)SOLAREDOE F37O370 POWER OPTIMIZERS UNE SIDE TAP - (NINA AC DISCONNECT (N)RM AC DISCONNECT •FUSIBLE,LOCNABIE -FUSIBLE,LOCKABLE 1 BRANCH OF •BOA�� BOAt..-- SOCKET ABA —.1 — ill i — fi /// /I BRANCH CFI —11 JF - (E)LOADS A I I — GROUD ELECTRODE ELEC. LEAD ATA3R,THRM2 WOK THRR42 AWO810-fl1,E1/4 AMMO,PV WIRE AWGN,TUEN8.W3DOEC AYAa es.TLWR4.S.BICIOEC AVM G#I0,T WIL2,EGC/LEC GNOME 1/14,4112,BBC SIGN OFF: CONDUIT,ar OW COMMIE.aw MIT COmuT.MP EMT CONCAVE.3N•EMT _ JOB NUMDCR 1240 UTILITY:NG OWNER TURNER REStBENC� DEEMrED, HA— .AGM A? PV5 TURNER,KHAHTEE F FsR RACKING:S5PROTEA BRACKET UTILITY ACCT#:28392-37037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM BY:ENEA SULUTI NS - -- MS MODULES(17)HANM AQPEAKDUOBLKML-G10400 NORTHAMPTON,MA,01060 6.00 kW AC - -- - REV: DATE IN ERTS: 1)SO ASS itmERTER sEe000J1IC gwo Kw) +1-917-202-0574 22N5R072 PAGE SAME: SINGLE LIME 4- 4. LEGEND to 8F SCALE:1'=15 M UTILITY METER DRYADS GRN INV INVERTER 0 -it'al AC DISCONNECT FOH m * MSP MAIN SERVICE PANEL > B DC JUNCTION BOX mops s I u MONITORING UNIT G Milli D DISTRIBUTION PANEL ■ IIIIIll � rLC LOAD CENTER II �::'all�` ATs 1 AUTOMATIC TRANSFER SWITCH ;�H CONDUIT 'NO H . G o o , a FENCE - /s IFS Q T V p)NF FT - Signed 11/11/2022 GWIEX: DE8 T1O* DESIGNED lit.: PAGE - TURNER-RESIDENCE _ HA - . A. EM. c WER RE1 36PROTEA BRACKET U11LJ1VACCT#.28392-37037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM REVEWBY' MS . ENER Y 50LUTI�N3 MODULES:(17)H NWHAQ.PEAKDUOBLKML-G10400 NORTHAMPTON,MA,01060 6.00 kW AC MS REV: DATE M/ERTBZ(1)SOLAREDGE IWNERT62 SEBOOOKIIS(6.00 KW) +1-917-202-0574 aAtermn PAGE NAME SITE PLAN ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED AC ALTERNATING CURRENT DISCONNECTING MEANS MAY BE POWER-CONDITIONING INVERTER. PV1 COVER SHEET BLDG BUILDING ENERGIZED IN THE OPEN POSITION,A 2. THIS SYSTEM HAS NO BATTERIES,NO UPS. CONC CONCRETE PV2 SITE PLAN SIGN WILL BE PROVIDED WARNING OF 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY C COMBINER BOX D DISTRIBUTION PANEL THE HAZARDS PER ART.690.17. GROUNDED. PV3 ARRAY DETAIL DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. - -- _-- EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE PV4 STRUCTURAL VIEWS (E) EXISTING IDENTIFIED BY PHASE AND SYSTEM PER EMT ELECTRICAL METALLIC TUBING ART.210.5. PV5 SINGLE LINE GALV GALVANIZED 3. A NATIONALLY-RECOGNIZED TESTING VICINITY PV6 LABEL SET / GEC GROUNDING ELECTRODE CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT R T - GND GROUND IN COMPLIANCE WITH ART.110.3. , �---F : ,\ HDa HOT DIPPED GALVANIZED 4. CIRCUITS OVER 250V TO GROUND SHALL x:. - �'3' w i '� • I CURRENT COMPLY WITH ART. 250.97,250.92(B) ; mq v, ' , ' ♦ ILA'),'` Imp CURRENT AT MAX POWER �, �I - K MD. INVS INVERTERS 5. DC CONDUCTORS EITHER DO NOT ENTER �� / �1rf r`,-7i Isc SHORT CIRCUIT CURRENT BUILDING OR ARE RUN IN METALLIC �Lj * ��YAI E kVA KILOVOLT AMPERE RACEWAYS OR ENCLOSURES TO THE `41a �-- kW KILOWATT FIRST ACCESSIBLE DC DISCONNECTING ` APPLICABLE CODES LBW LOAD BEARING WALL MEANS PER ART.690.31(E). t.•- 2015 IBC Signed 11N72022 MIN MINIMUM 6. ALL WIRES SHALL BE PROVIDED WITH 2020 NEC (N) NEW STRAIN RELIEF AT ALL ENTRY INTO BOXES NEC NATIONAL ELECTRIC CODE AS REQUIRED BY UL LISTING. ,g AHJ: NIC NOT IN CONTRACT 7. MODULE FRAMES SHALL BE GROUNDED NTS NOT TO SCALE 63 Drt AT THE UL-LISTED LOCATION PROVIDED �ds Green, CITY OF NORTHAMPTON OC ON CENTER gY THE MANUFACTURER USING ULLISTED Northampton, MA... 212 MAIN ST#100 P PANEL BOARD A NORTHAMPTON,MA 01060 PL PROPERTY LINES GROUNDING HARDWARE. r +1 413-587-1240 PV PHOTOVOLTAIC 8. ALL EXPOSED METAL PARTS(MODULE - 1 PVC POLYVINYL CHLORIDE FRAMES,RAIL,BOXES,ETC.)SHALL BE \ ' S SUBPANEL GROUNDED USING UL USTED LAY-IN LUGS +- , UTILITY: NG SCH SCHEDULE LISTED FOR THE PURPOSE.POSTS SHALL ,+ •'V SS STAINLESS STEEL BE MADE ELECTRICALLY CONTINUOUS —_ SSD SEE STRUCTURAL DIAGRAMS a`* WITH ATTACHED RAIL. EMPOWER ENERGY SOLUTION STC STANDARD TESTING CONDITIONS E, `� �_ ' SWH SOLAR WATER HEATER 9. MODULE FRAMES,RAIL,AND POSTS - - riik .e 30 OLD KINGS HWY S#1001 DARIEN , TYP TYPICAL SHALL BE BONDED WITH EQUIPMENT tc r CT,06820-4551 UON UNLESS OTHERWISE NOTED GROUND CONDUCTORS AND GROUNDED - i y- e••, UPS UNINTERRUPTIBLE POWER SUPPLY AT THE MAIN ELECTRIC PANEL. ' ,r•14 -w, i •0 LICENSES ✓ VOLT 10. THE DC GROUNDING ELECTRODE Y- ' HIC: 198351 Vmp VOLTAGE AT MAX POWER CONDUCTOR SHALL BE SIZED ELEC:8209-EL-Al Voc VOLTAGE AT OPEN CIRCUIT ACCORDING TO ART.250.166(B)&690.47. s W WATT 3R NEMA 3R,RAIN TIGHT - Iler4V JOB NUMBER pip.1240 ��� /�y� � JV�I�IJMOGR VIYI�.IRi OWNER' DESCRIPTION. DESIGNED BY- HA I11DRYA KHAHTEE— NCE HA P\I R Cyy�sZ RACIQJC�tS.5PROTEABRACKET UTILITYAQCT1628392.97037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM "°" Ne Gv saLu I Ns 1 MODULES:(17)HANV HA WEAK DUO BLK ML-G10 403 NORTHAMPTON,MA,01060 6.00 kW AC MS REV: DATE +1-917-202-0574 77A6ROP3 PAGENN1E: COVER SHEET MIERTSt(1)SOLi4Fi®CE NdNERTH2 SE9000FWS 00 KW) 1 .. + LEGEND 8 A SCALE:1•=15• M UTILITY METER DRYADS GRN INV INVERTER 0 AC AC DISCONNECT FOH m MP MAIN SERVICE PANEL D LB ' DC JUNCTION BOX ...Er i MONITORING UNIT 0 D DISTRIBUTION PANEL MI 1 ■ ���,� �M` LC LOAD CENTER � C..... :JI .� 1 ATs AUTOMATIC TRANSFER , SWITCH ;,� _ CONDUIT '� H FENCE 1/4YAL ," signed 1 V11/2022 JOB N 1 :NC amok DESCRIPTION DESIGNED BY: PAGE JOB NC TURNER, GRN 1 tt TURNER ROOF HA �` ,� �/y�p ��, W4pWG:S6PROTEABRACI�T unuTYAccT#2839237037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM REVIEW Br V ENERGY SOLU I N9 MS MODULES:(17)HAt WHAQ.PEAK DUO SU<ML-G10400 NORTHAMPTON,MA,01060 6.00 kW AC REv, DATE: M/ERTSt(1)SOLAFt®GE INVERTER S69000144S(6.00 KW) +1-91 7-202-0574 noeamz ^"� tea"" 4 + LEGEND A - ROOF r R N RAFTERS SCALE:V=10' RAIL MOUNT ®® OBSTRUCTION - MAIN SERVICE PANEL TOTAL PEMETRATRTNCOUNT s. UTILITY METER MP11:11) AC DISCONNECT 11 MODULES / MA SMART METER ) " �/ AC DISCONNECT INVERTER MP, '"� CONDUIT RAFTER PROFILE2J(8 JUNCTION BOX RAFTER SPACIHa 22 C.J.SPACI 22' / SPACCH �. m `./ SPACING \ • MCI ROOF PITCH 7T �f� ARRAY PRCH �y{ 9T ROOF AZIMUTH 133' ® a o - ARRAY AZIMUTH. 133' ROOF SURFACE fr sum ROOF m m m m Elm TYPE_ STORIES �''7. 2 l MP2 lIM ® - - RAPIER 2X6 TRENCH -26ft ® \\\\\\J� m R^ 2r C.J SPA 2Z' I ATTACHM 4. SPACING ROOF PITCH ;., 20' tH OF� ARRAY PITCH 20' �` ROOF AZIMUTH 133' P ARRAY AZIMUTH +33' WY,L ,,� ROOF SURFACE METAL ROOF I I IL H : TYPE '� STORIES 2 MP2 / ; ' SS,UWAL Evio' (6) MODULES Signed 11/11/2022 irr ®® ROOF LEAD m SIGN OFF: OB NUMBER.1240 1 m�.�G - OWNER DESCRIPTION: DESIGNED BY: PAGE PV3 JOB V�1Y�� NO � TUFtNthi,KHAN Itt TURNtKKtStDE1Vf;�- HA gvec,r,Tn WICKINQS-5PROTEABRAd�T UTILITY ACCT#:28392-37037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM REVIWOY: give sOI.uTTONs .(17)HIWVVHA()PEAKDUOBLKK.-G10400 NORTHAMPTON,MA,01060 6.00 kW AC MS REV: DATE: MIERT62:(1)SOI,AREDGE NJVERTH2 SE8000FKJS(8.00 KVV) +1-917-202-0574 uasrma PAW NAME: ARRAY DETAIL / 18'-2" ..!.. 2 / 6. , , , SOLAR MODULE - '-1' if lik . .... ' •ie-----K : : W S-5 PROTEA BRACKET . - *-; ATTACHMENT 1 ' 15-4' --'!. ,....v., , 1 .' : i Ct •' , 1 6 , -e 2A6 NOMINAL ion . S1 STANDOFF . SCALE NTS 1.-4" / // 6'-10' - 1 MP1 SIDE VIEW , NTS , SOLAR MODULE RAFTERS:2X6 @ 22"O.C. 1.-4" / // / MAX SPAN:6'-10" MP2 SIDE VIEW Ir. __ ..........„/ 01.1H OF NTS SLATE PLATE FLASHING - ' ' . i:. ''' t -,0*4P: : RAFTERS:2X6 @ 22"0.C. MAX SPAN—14' / 1t ' METAL ROOF, lakc: ..4...,4- -4'/OIVAL-4".- CONCRETE TILE SLATE ROOF Si STANDOFF Signed 11/11/2022 SCALE NTS 2X6 NOMINAL JOD NUMBER:1240 U Y:N TILITG OMER TURNER,KHAHTEE DESOPtP OOP!: PA TURNER-RESIDENCE DUNNED SY: HA GE FmestorAa RACI<ING:S-5 PROTEA BRACKET unurif ACCT M2839247037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM R'Lry""" MS PV4 MODULES:(17)HANWHA aPEAK DUO SU(ML-G10 400 NORTHAMPTON,MA,01060 6.00 kW AC _. REV DATE INVERTER:(1)SOLAREDGE IIWERTER sEexci+us goo KW) +1'917-2°2'13574 : 221062022 PAGE MAME STRUCTURAL VIEVVS BREMER - FUSE —•— svgn:m EARTH GROUND INVERTER OUTPUT CURRENT(A 25 EGG 120/240V INVERTER BACKFEED(Ap 31 - _ SINGLE PHASE OVERHEAD MSP RATING(A)= 200 UTILITY SERVICE MAIN BREAKER RATING(A 200 MAX BACKFEED(A)= 40 rMET1112 TIE IN: LST NMI. ■ ■ ■ ■ I ■ (N)SOIADECK I JUNCTION BOX (N)80LAREODE INVERTER -IMF USED (N)(17)I4A1IWI44 OPEN DUO RUC IL•010400400W PV MCSN E EI 8E000014UB -GROUNDED (17)Pn APFOGE P370 POWER OPTIMIZERS LINE SIDE TAP (N)BOA AC DISCONNECT (N)60A AC DISCONNECT -FUSIBLE.LOCKABLE -FUSIBLE,LOCKABLE - ,BRANCH OFI / -40A FUSES (N)MA SWAT PETER -40A FUSES r= _--.. - NETBIlOc10T —.\ 40A 1 �/� �I'R .1=1 n -----. rt( BRANCHOF8 ---------- -------- -- — ------ - //�l I— — 2ooArlo • U E LOAD LINE LOAD 1 i g JI I —L — GROUND ELECTRODE ELEC. LEAD AWOK.TIMF2 AMOK.TIMN2 'Ave/1Q.TM'I42 AWOA,O.Pv WIRE Awe K.TIIRL2.E0C/OEC AMOK.7714442.EOCAiEC MVO I10.T11NN2.EOCRIEC AWO 410 TMWN-S,EGC SIGN OFF: COID(R.W EMT CONDUIT,SW BIT COIWt,W BIT CONDulT.3M-EMT —1 OMER: DESCRIPTION: OEIDI.D IY: - PAOL .� �, IUNNtR,IV1ARIt TURNED PV5 EMPOWER MS R RACKING:S5PRO�TEABRACKET�uTMA CT#: -3� 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM REVIEW sv: ENERGY SOLUTIONS MODULES:(17)HANVN1AEAKDUOBLKN�-G10400 NORTHAMPTON, MA,01060 6.00 kW AC O.P Rev: DATE MIERn62:0)SOLAFiEDGE NJNERTEFt SE8000H11S(6.00 Kw) +1-917-202-0574 220612022 PAGEIOE: SIN(LEUE NOTE: NEC 690.17(E) BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS See Figure 690.1(b)diagrams for location in system SHALL COMPLY WITH (IN ORDER OF PRIORITY)AHJ&FIRE Disconnects PV from all other wiring systems DEPARTMENT AMENDMENTS,STATE CODE,AND ANSI Installed in a readily accessible location GUIDELINES.THIS PAGE IS INTENDED OR SIGNAGE/LABEL Permanently marked: PV SYSTEM DISCONNECT, or equivalent VERBIAGE ONLY. Where line/load may be energized in open (off) position: OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS IS Marked with the following or equivalent TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT IN NEC 690.31 (D) 2; 2012 IFC 605.11 WHICH THE EQUIPMENT IS INSTALLED.NO STICKERS ARE On or in a building, unless location/purpose is evident !,PERMITTED. WARNING Raceways, enclosures, every 10', suitable for environment 2020 NFPA 70, NEC 690.53 Minimum 3/8" CAPS White on Red, Reflective DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE Maximum system voltage calculated in accordance with 690.7 ELECTRICAL SHOCK HAZARD At one of the following locations: DO NOT TOUCH TERMINALS • DC PV system disconnect TERMINALS ON BOTH THE LINE AND LOAD WARNING • PV system electronic power conversion equipment SIDE MAY BE ENERGIZED IN THE OPEN • Distribution equipment associated with the PV system POSITION PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT NEC 705.12(D)(2)(b) MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER PLACE THIS LABEL AT P.O.C. TO SERVICE OR DC-TO-DC CONVERTER DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND 2020 NFPA 70, NEC 690.56(c) AIFINSTALLED) SUBPANEL IF APPLICABLE)) LOCATED AT EACH SERVICE EQUIPMENT LOCATION WHERE PV IS CONECTED"OR APPROVED READLY 2020 NFPA 70, NEC 690.54 VISIBLE LOCATION INTERACTIVE SYSTEM POINT OF INTERCONNECTION R N I N SHALL INCLUDE SIMPLE DIAGRAM OF BUILDING All interactive system(s)points of interconnection with other \/\//\ G AND ROOF sources shall be marked..." • Accessible location at disconnecting means, PHOTOVOLTAIC SYSTEM EQUIPPED • as a power source: INVERTER OUTPUT CONNECTION TURN RAPID SHUTDON ITHRAPIDSHUTDOWN •W Rated AC output current DO NOT RELOCATE THIS SWITCH TO THE"OFF" Nominal operating AC voltage OVERCURRENT DEVICE POSITION TO SHUTDOWN PV SYSTEM AND REDUCE MITGII PHOTOVOLTAIC AC DISCONNECT SHOCK HAZERD IN THE ARRAY sue. RATED AC OUTPUT CURRENT: I NOMINAL OPERATING AC VOLTAGE: J DESCRIPTION: DERIGOED BY: PAGE TEE TURNER RESIDENCE HA PV6 EMPOWER RACKING:S5PROTEA BRACKET IunuTYAcCT*.2839237037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM REVIEW BY: aNeacv SOLUTIONS MS MODULES:(17)HANWHAQPEAKDUOBLKL-G10400 NORTHAMPTON,MA,01060 6.00 kW AC M REV: DATE: INVERTER:(1)SOLAREDGE INVERTER SE60001-411S(6.00 KW) +1-917-202-0574 RAGE WEE ueaeers NEC 690.56(B)/705.10/712.10 2020 NFPA 70, NEC 690.56(c)(2) NEC 705.12(B)(3)(3) "AC Combiner Panel" Permanent plaque or directory installed at either: SWITCH LABELS THAT INCLUDE THE FOLLOWING: • Sum of ampere ratings, excluding source OCPD Each service equipment location MINIMUM 3/8"CAPS,WHITE ON RED,REFLECTIVE • Label applied adjacent to distribution equipment Approved readily visible location REQUIRED FOR ALL SYSTEM TYPES • The following or equivalent wording: Marked with the following wording: Denote location of each power source disconnect RAPID SHUTDOWN Grouped with other plaques or directories SWITCH FOR WARNINGCorrectly oriented with respect to diagram's location SOLAR PV SYSTEM ACAUTION NEC 690.35(F) THE EQUIPMENT FED BY MULTIPLE SOURCES. PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, TOTAL RATING OF ALL OVERCURRENT DEVICE, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED SHALL NOT EXCEED AMPACITY OF BUSBAR. T10S R O LDt.G It AR O TOTOLTAICLS ST INAT,IL SOURCES CIRCUITS MAY BE EXPOSED DURING SERVICE: SOLAR STN anon uo s DIKOKCT LOLATNNIS N.SWATS IDLO. UTILITY MT1• 'n'• T _16 D Y MAIM' ` r�; °'LK � "NEC 690.56 (Informational Note) WARNING • MA Fire Code (527 CMR 1) requires signage: _(UC.R • Adjacent to building or service disconnect - ELECTRICAL SHOCK HAZARD • Identifies responsible party for operation NEC 705.12(C) THE DC OF THIS PHOTOVOLTAIC SYSTRS EMTAARE UNGROUNDED of system Equipment containing overcurrent devices AND MAY BE ENERGIZED • Provides contact informatio supplying power to busbar or conductor Supplied from multiple sources NEC 690.5(C) "Marked to indicate the presence of all sources" PLACE THIS LABEL ON INVERTER(S)OR NEAR GROUND-FAULT INDICATOR(ON INVERTER(S)U.O.N.) ' PV SYSTEM INSTALLATION BY: ABC SOLAR WARNING ,CONTACT PHONE: 857-600-8995WARNING IN CASE OF EMERGENCY DIAL 911 ELECTRICAL SHOCK HAZARD DUAL POWER SOURCE SECOND IF A GROUND FAULT IS INDICATED, SOURCE IS PHOTOVOLTAIC SYSTEM NORMAI I Y GROUNDED CONDUCTOR BE UNGROUNDED AND NERGIZED JOB NUMBER:1240 t ml rtv�rrty fir_ OWNER: DESCRIPT-- -TURNERN °EB101EDA w P\f� f�iV€1 KHAtiTEEION: RESIDENCE D HA Eorgy g 'x� BRACKETACCT#:28392-37037 63 DRYADS GRN 6.80 kW DC ROOF SOLAR SYSTEM " NBY ENERGY 56WTIDN9 :(17)HANWMAQPEAK DUO BLKAIL-G10400 NORTHAMPTON,MA,01060 6.00 kW AC MS REV: DATE INVERTER:(1)SOLAREDGE INVERTER SE60001-I11S(6.00 KW) +1-917-202-0574 22ro6r2022 PAGE NAME: LABEL SETS powered by Q.ANTUM /DUO © • • • t t l f . ,1 1, `` •', ', Q. PEAK DUO BLK ML-G10+ EUPD RE EUPD RESEARCH TOP BRAND PV=`_ -_ 385 410 '.,�, [ TOP BR•u AND PV stARCN w'J:'w-VA 2018 2021 447417 ENDURING HIGH PERFORMANCE MYR Warranty CELLS PrOduc,&PodO n$r,R told Security �Jn'n BREAKING THE 20%EFFICIENCY BARRIER nl ll tl l Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.1%. THE MOST THOROUGH TESTING PROGRAMME IN T INDUSTRY Q CELLS is the first solar module manufacturer to pass the mo t comprehen- - sive quality programme in the industry.The new"Quality Contr lied PV"of the independent certification institute TUV Rheinland. „ INNOVATIVE ALL-WEATHER TECHNOLOGY r?; Optimal yields,whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Hot-Spot Protect and Traceable Quality Tra.QTN4. rif§r EXTREME WEATHER RATING High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 2g A RELIABLE INVESTMENT EAR6 Inclusive 25-year product warranty and 25-year linear performance warranty'. See data sheet on rear for further information. THE IDEAL SOLUTION FOR: 1` Rresioo dftope ntia arrays on Sfd� l buildings Engineered in Germany Q CELLS MECHANICAL SPECIFICATION Format 1879mm x 1045mm x 32mm(including frame) Weight 22.0 kg I- 10e8mm A6A m" Front Cover 3.2 mm thermally pre-stressed glass with - ' anti-reflection technology <,e�0b"cPa.00s°.n I 1 B Back Cover Composite film __. ri.°°- Frame Black anodised aluminium °a°m Cell 6 x 22 monocrystalline Q.ANTUM solar half cells fa 1046,,,,, Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67,with bypass diodes Cable 4mm'Solar cable;(+)21260mm,(-)a1250mm I "'60in b Connector St8ubll MC4;IP68 4.Manny slab(DUAL A) +I , '1 I-'2"„" DDUAL* it a l ° , Nbmml{-)i."" ELECTRICAL CHARACTERISTICS POWER CLASS 985 390 395 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W I-OW) Power at MPP1 Puss [W] 385 390 395 400 405 410 Short Circuit Current' lsc [A] 11.04 11.07 11.10 11.14 11.17 11.20 E E Open Circuit Voltage' V. [V] 45.19 45.23 45.27 45.30 45.34 45.37 .8 Current at MPP limp [A] 10.59 10.65 10.71 10.77 10.83 10.89 Voltage at MPP VNPP [V] 36.36 36.62 36.88 37.13 37.39 37.64 Efficiency' q [%] z19.6 z19.9 z20.1 z20.4 z20.6 20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Power at MPP Pup,, [W] 288.8 292.6 296.3 300.1 303.8 307.6 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 9.03 'c E Open Circuit Voltage V. [V] 42.62 42.65 42.69 42.72 42.76 42.79 Current at MPP I,,,RP [A] 8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP VNp, [V] 34.59 34.81 35.03 35.25 35.46 35.68 'Measurement tolerances PNsv 33%;Isc;V.±5%at STC:1000 W/m,25±2°C,AM 1.5 according to IEC 60904-3•'800 W/m',NMOT,spectrum AM 1.5 CI CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE a • "o T r r 2CFLISi a _ e... e. At least 98%of nominal power dur- -- I 1 ing first year.Thereafter max.0.5% u ' 1 LLo a degradation per year.At least 93.5% w sae L L of nominal power up to 10 years.At LL 1 ' '-g least 86%of nominal power up to i i i 1 3 0 " 26 years. F NI :1 r r Q w i ' All data within measurement toter- 5 1 fa 2. I ances.Full warranties In accordance p with the warranty terms of the 100 400 e00 eea ieee o - Q CELLS sales organisation of your IRRADIANCE IW/m't C e no a a a respective country. °.,ate m,� ,o�.a:�s,o.A.m YEARS Typical module performance under low irradiance conditions in comparison to STC conditions(25°C,1000 W/m'). a TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vac (3 [%/K] -0.27 0 Temperature Coefficient of PNPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°C] 43±3 R 0 PROPERTIES FOR SYSTEM DESIGN M Maximum System Voltage Vsrs [V] 1000 PV module classification Class II o Maximum Reverse Current IR [A] 20 Fire Rating based on ANSI/UL 61730 C/TYPE 2 c? Max.Design Load,Push/Pull [Pa] 3600/2660 Permitted Module Temperature -40 -+85°C Max.Test Load,Push/Pull [Pa] 5400/4000 on Continuous Duty o 0 a QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Quality Controlled PV-TUV Rheinland: I�/A <IVI IV'/1 Ko ®s IEC 81216:2018;IEC 81730:2016. A° L�,iV/J ,,O IVI'J O-O O This date sheet complies Lr. ♦ ♦ 0 with DIN EN 50380. TIM'. °"A [ C Horizontal 1940mm 1100mm 1220mm 751kg 28 pellets 24 pallets 32 modules 1 QCPV Certification ongoing. -- ` packaging Certification holder: Di,lirwn Hanwhe 0 CELLS GmbH 3 1 Note:Installation instructions must be followed.See the Installation and operating manual or contact our technical service department for further information on approved installation and In 8 use of this product. 2 Made In Korea o Hanwha 0 CELLS Australia Pty Ltd m Suite 1,Level 1,15 Blue Street,North Sydney,NSW 2060,Australia I TEL+61(0)2 9016 3033 1 FAX+61(0)2 9016 30321 EMAIL q-cells-australia@q-celis.com I WEB www.c-cells.com/au Engineered in Germany Q CELLS _ : Single Phase Inverter Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ with HD-Wave Technology < SE7600H-US/SE10000H-US/ SE11400H-US mMODEL NUMBER SE3000H-US SE3600H-US SES000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US for North America T APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 N SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ OUTPUT SE7600H US/SE10000H US/SE11400H US Rated AC Power Output 3000 3 ® woo sao® 7600 10000 1240V100000 208V VA f m Munnetra AC Power Output 3000 3 800 0 •2 , 10000 0• VA I 1 AC Output Voltage Min.-Nom.-Max. YEAR (211-240-264) ' '' 1 I I V 1 Vac O \WARRANTY AC Output Voltage Min.-Noe.-Max. - - - - r ^ (183-208-229) V Vac v ' AC Frequency(Nominal) 593-60-60.50 Hz O 0 Madmum Continuous Output 12.5 16 21 25 32 42 47.5 A Current 0240V Maximum Continuous Output - 16 - 24 - - 485 A Current 0208V - _ _ ___ _- O O Power Factor L A4u9able-0-85 to 0a5 O • GFDi Threshold 1 A Utility Monitoring,!standing Protection Ws Country Configurable Thresholds INPUT - • sour ,:� —HD • • solar ?[' _HD.. . 0 Madmum DC Power 0240V 4650 5900 7750 9300 11800 15500 17650 W • Maximum DC Power 0208V - 5100 - 7750 - - 15500 W s 17- - a Transformer-less.Ungrounded Yes • 0 Maamumip/A Voltage 480 . - --_- We O 0 Nominal DC Wa age aage 380 400 We 10 Madmtm'Net anent 0210Vm 83 10.5 135 165 20 27 30.5 Ads Maximum Input Cune t 020890 - 9 - 135 - - 27 Adc iso Max.Input Short Circuit Curran 45 Ad. o 0 O • Reverse-Polarity Protection `Ass _— _ - ...' _ Ground-Fault Isolation Detection 60062 Sensitivity Madmum Inverter Efficiency 99 1 992 % CEC Weighted Efrjerny 99 99.240V % 98.5.208V Nighttime Power consumption .25 w Optimized installation with HD-Wave technology ^ ot her regionals ngspleattr SolaEdoe support n A higher parent source may to used tv nw rter will heat it,"pr:oral to the vetoes stagy / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small,lightweight,and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a sartphone using the SolarEdge SetApp / Built-in module-level monitoring tn / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in consumption metering(1%accuracy)and production revenue grade / Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20) shutdown for NEC 2014 and 2017,per article b90.1 i andbvu.12 solaredge.corn solar . • / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE500OH-US/SE6O0OH-US/ SE7600H-US/SE1000OH-US/SE11400H-US MODEL NUMBER SE 3 BOOH-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES „mrrunicatian Interfaces .._ R5485,Ethernet Zgeee lophonNNL Cellar(optional) Revenue Grade Metering ANSI C1220 Optional. Consumption metering Inverter Commissioning With the SetApp mobile application using Buis-in wrF Access Point for Local Connection Rapid Shutdown-NEC 2014 and I Automatic Rapid Shutdown u Grid Disconnect pon 2017690.12 � STANDARD COMPLIANCE Safety U11741,U11741 SA,U1.16998,CSA C222 Canadian AFCI armrdi g to ILL.M-07 Grid Connection Standards IEEE1547,Rule 21.Rude 14(HO Emissions FCC Part 15 Gass B INSTALLATION SPECIFICATIONS AC Output Condit Size/AWG 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC input Conduit Sae/s of Strings/ AWG 1"MardmUn/1-2 strings/14-6 AWG 1"Maa6Mtm/t-3 sittings/14-6 NAG Dinensbnsbns wth Safety Switch 17.7xUbx6.8/450x 370x174 21.3 xUb x 7.3/S40x 370 x185 mm Weight with Safety Switch 22/10 I 25.1/11.4 I 262/119 38.8/17.6 4/kg Noise <25 .50 dad Cooing Nabxal Convection Operating 7anperatuae Range -40 b a140/-40 to.604 'WC Proteakm Rang NEMA 4X(Inverter with Safety Switch) Inverter with Reeems Grade Meter PM SEamdl-US000BNC4,inverter with Revenue Glade PloducWn aril Consurplbn Meter P/N,SEaaaA-US000BNI4.For mrwarptlon meting.cum.Eansfpncn should be aide d sepealeh/SEACT0750-200NA-20 or SEACT0750-400NA-20.20 units per bit •FJI poav rp to•bat 5PC/12YF far power de-rateg tibmradon rcter b.heps/Mw.r0Wedpe.o0n614WMaliV➢RX-IenWeraturderawg-rote-rra.pdt How to Enable Consumption Monitoring By simply wiring current transformers through the inverters existing AC conduits and connecting them to the service panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase-in RG r wand . HD-wave technology and built-in RGM and Service Pang consumption monitoring • Grid 0 Eg 1 Cf 1.1 Nl2 . Shielded Shielded CATSe cable , i s e• 61 Li I AC Conduit mSell..,.T. argn ter..w.dtos0atn0...5aavEdx.r,go.ornnIMIns«,at ...ow n.a.*atom,.T.fS Inc Al RoHS We,m.a.,,ww mmrbM hoe.ore U.demarts a 11.r..oee one,Dan Cl%hslln t0500 Seam,to&I.9e.t.S Power Optimizer Evik%.) For North America P370 / P400 / P401 / P485 / P505 m 25 O YEAR WARRANTY 111.11.1111 111111 PV power optimization at the module-level / Specifically designed to work with SolarEdge / Fast installation with a single bolt inverters / Next generation maintenance with module- / Up to 25% more energy level monitoring / Superior efficiency (99.5%) / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid / Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading / Module-level voltage shutdown for insaller and firefighter safety / Flexible system design for maximum space utilization solaredge.com so t a r . s z Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model P370 P400 P401 P485 P505 (typical module compatibility) (for higher-power 60 (for 72&96- (for high power 60 (for high-voltage (for higher and 72-cell modules) cell modules) and 72 cell modules) modules) current modules) INPUT Rated Input DC Powerw 370 400 485 505 W Absolute Maximum Input Voltage 60 80 60 1250 830 Vdc Noc at lowest temperature) MPPT Operating Range 8-60 8-80 8-60 125-105 12.5-63 Vdc Maximum Short Circuit Current(Ix) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.8 Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1±0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 NEC 2014,2017&2020 NEC 2014,2017&2020 EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(dass II safety),UL1741 Material UL94 V-0,UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 129x153x27.5/5.1x6 129x153x33.5/ 129x153x29.5/5.1x6 129x153x33.5/5.1 129x162c59/ mm x 1.1 5.1 x 6 x 1.3 x 1.16 x 6 x 1.3 5.1 x 6.4 x 2.3 /in Weight(including cables) 655/1.4 750/1.7 655/1.4 845/1.9 1064/2.3 gr/lb Input Connector MC40 Single or dual MC4 MCP Input Wire Length 0.16/0.52,0.9/2.95" 0.16/0.52 0.16/0.52,0.9/2.95N1 0.16/0.52 0.16/052 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 1.2/3.9 m/ft Operating Temperature Ranger -40 to+85/-40 to+185 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % (1) Rated power of the module at STC will not exceed the optimizer'Rated Input DC Power'.Modules with up to+5%power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3)For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,instating one P485 dual version power optimizer connected to one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals (5) For ambient temperature above+85'C/+185'F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Single PI, Three Phase for Three Phase for Inverter"' HI) V1./,tvt, Single phase 208V grid 277/480V grid Minimum String Length P370,P400,P401 8 10 18 (Power Optimizers) P485,P505 6 8 14 Maximum String Length(Power Optimizers) 25 25 50 Maximum Nominal Power per String 57000(6000 with 5250rei 6000m 12750,0 W SE7600-US-SE11400-US) Parallel Strings of Different Lengths or Orientations Yes (6)For detailed string sizing information refer to:http✓/www.solaredge.com/sites/default/(iks/string_sizing_na.pdf (7)It Is not allowed to mix P485/P505 with P370/P400/P401 in one string (8)If the inverters rated AC power s maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power.Refer to:https://www.solaredge. com/sites/default/tles/se-power-optimizer-single-string-design-application-note.pdf (9)For 208V grid:it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,DXIW o SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, 4,1Y- RoHS Inc AN other trademarks mentioned herein are trademarks of their respective owners.Date.04/2021 DS-000044-2.0-NA.Subject to change without notice. Intertek CD ,S 5 ! ° „----., 4,00 al 03 0 The Right Way SI - 0 I 0 I ,n ProteaBracketTM 3 / �d�. o Q ProteaBracket"""is the most versatile �> L attachment solution on the market,fitting , o co most metal trapezoidal sheet profiles with __ •4-+ and without intermediate insulation.It N features an adjustable attachment base and Emultiple solar module attachment options , 24,(illustrated on back)to accommodate varying widths and heights.There are no fill messy sealants to apply and no chance for C leaks;the ProteaBracket comes with factory- applied,adhesive rubber sealant to ensure iquick installation and a weather-proof fit. C The ProteaBracket is mounted directly onto tB the crown of the panel,straddling the 100111011111111 174 profile.No surface preparation is necessary; o simply wipe away excess oil and debris, E align,and apply.Secure ProteaBracket through all 6 pre-punched holes. co ., i ProteaBracket is the perfect match for the 5- 5-PV Kit,for a solar attachment solution that 000 is both economical and easy to use. 4.0 S-5!® ProteaBracketTM is a 0 (EL I— . s versatile bracket that adjusts , easily to most trapezoidal roof profiles. a) S-5!PV kits have an M8 bolt and are suitable •- for use with all S-5!clamps. ProteaBracketTM is the perfect solar attachment solution for most trapezoidal exposed-fastened metal roof profiles. No messy sealants to apply: the factory-applied adhesive rubber sealant weather-proofs The Right Way and makes installation easy. S-5!•holding strength is unmatched in the industry. ProteaBracket TM Each ProteaBracket'"comes with a factory-applied, adhesive rubber sealant on the base.A structural A2 ti24.64mm stainless steel bimetal attachment bracket,ProteaBracket sz�m ,, 25.40 77,7-7' . is compatible with most common metal roofing materials. Aem Z_,,:; ii All four pre-punched holes must be used to achieve ,, tested strength.For design assistance,contact Safintra ` 8.38mm 9 9 South Africa(and see our website www.safintra.co.za), 8.38mm or i 1111 Thru Hole 4x visit www.5-5.com for the independent lab test data that 1/ .86mm can be used for load-critical designs and applications. ' ` Also,please visit S-5!website for more information 9.91mm including metallurgical compatibilities and specifications. /6.2 m , •; 1 Multiple Attachment r Options: f 0 60.71mm Factory Applied / 99.82mm Sealant Please note All measurements are rounded to the second decimal place. - ... .'. .- ProteaBracketTM with Top Rail option for PV f FLUTELINE attachment , s 1 4 a''T ! t L t ProteaBracket TM with ! 1 ! S-5-PV Kit option (if not using a rail) It Or-1167 1 lia.`�! S-51•Warning!Please use this product responsibly! Sole Agents for Africa: S-51 Brackets and clamps are not tested for performance as part of a Fall Arrest or Personal Safety system.These applications need to be II tested as a dynamic system and warranties or test results must be issued by the system provider. mmnimi=MIMNIMMNIIIIIIIISafintra,Safal Group and its subsidiaries provide no warranties or any assurances in this application,and will accept no claims of any nature whatsoever arising out of any such applications. S A F I N T R A Products are protected by multiple international patents.For published data regarding holding strength,bolt torque,patents and trademarks visit the S-5!website at www.S-5 corn world oleos roofing systems Copyright2013,Metal Roof lnnovatbns,Ltd.S-5!products are patent protected. www.safintra.co.za/www.saf ntr$.com S-5!Aggressively protects its patents,trademarks and copyrights. Empower Energy Solutions Inc. EMPC5WEP 15 June street, Ste 2A, Woodbridge, CT 06525 MA Contractors Registration No.:198351 ENERGY SOLU.1TIf_tNF` RESIDENTIAL SOLAR INSTALLATION AGREEMENT Customer 1 Name: Khahtee Turner Phone: +1-917-202-0574 Email: khahtee(Studiocreativeplay.org Customer 2 Name: Phone: Email: Street Address: 63 Dryads Grn Town: Northampton State: MA Zip: 01060 Solar Consultant Name: Ryan Severin Phone: +1-413-687-7894 Email: ryan s©empnwerenergy.ho PRELIMINARY DESCRIPTION OF THE PROJECT AND ESTIMATE OF THE SIGNIFICANT MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED Module Name: O-Cells 400 Mod. Quantity: 17 System size (kw) 6_8 Inverter: SolarFcige Structural & Electrical Requirement: If any additional work i.e., attic bracing, electric panel upgrade, re-roof, tree removal etc. is required analysis of the site surveyor&structural engineer, an additional fee will be assessed upon the Customer. i' (Customer Initials) PAYMENT TERMS: The Customer agrees to pay the Company the total amount of$ $54,437 (the "Total Price") in exchange for the System. This total does not reflect any incentives the Customer may be entitled to. Payment Method: Cash, ti Financed, Financing Company Concert Financed Projects: Financed projects are subject to payment schedule terms of Customer's financier. Payments will be made directly from financier to the Company. Cash Projects Payment Schedule (Applies to Cash Projects only1 Installment 1 (30%): $ N/A due immediately. Installment 2 (70% minus $1000): $ N/A due upon permit submission. Installment 3 ($1000): $ N/A due day of install completion. Notes: CUSTOMER AND SOLAR CONSULTANT HAVE REVIEWED THE ABOVE INFORMATION AND THE TERMS AND CONDITIONS ATTACHED, AND AGREE TO THIS AGREEMENT: Notice to Customer: (1) Do not sign this agreement if there are any blank spaces. (2) All contractors and subcontractors performing residential contracting services in Massachusetts must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. (3) You are entitled to a copy of this Agreement at the time you sign it. (4) You may at any time pay off the full,unpaid balance due under this Agreement and in so doing you may be entitled to receive a partial rebate of the finance charges. (5)The Company has no right to unlawfully enter your premises or commit any breach of the peace to repossess goods purchased under this Agreement. (6) You may cancel this Agreement if you did not sign the Agreement at the main office or a branch office of the Company, provided you notify the Company at its main office or branch office shown in the Agreement by registered or certified mail,that shall be posted not later than midnight of the third calendar day after the day on which the Customer signs the Agreement,excluding Sunday and any holiday on which regular mail deliveries are not made. See the attached notice of cancellation form for an explanation of Customer's rights. CUSTOMER 1 SOLAR CONSULTANT Signature: PULA L V � . eitin Date Signed: 09 / 02 / 2022 Signature: J� Date Signed: 09 /02 /2022 CUSTOMER 2 Signature: Date Signed: (Terms and Conditions attached) for If.. h57drhrirh7hfr.65frcin754dR3h(137c17fcl15hrdp4c1 TERMS AND CONDITIONS THIS RESIDENTIAL SOLAR INSTALLATION AGREEMENT(this"Agreement")is made effective as of the date signed by the Customer (the "Effective Date"), between the Customer whose name and signature appears above, and Empower Energy Solutions, Inc., a Connecticut corporation (the"Company").This Agreement relates to the installation of a certain System on the residential structure located at the address set forth above (the "Home"), which Home is owned by the Customer. 1. Installation Timeline. The Company will install or cause to be installed the System within a reasonable amount of time after execution of this Agreement but no later than 12 months from the date of a work order or last amendment to this Agreement (whichever occurs last). If a financing company is involved, the lender will require the Company to perform the installation with a required timeline. 2. System. The Company will provide the following to the Customer at the Home (collectively,the"System"): a. The Company will obtain any necessary permits, at the Company's cost.The Company is not be responsible for delays in work due to the actions of any permitting and regulatory agencies or their employees; and b. The Company will cause the complete installation of a roof mounted solar photovoltaic electric generation system, with the components and specifications set forth above (as described, the "Solar Equipment"), according to final plans and specifications to be provided by the Company and approved by the Customer. All work by the Company is brought to the existing electrical connection; once at the electrical connection point, the actual connection will need to be made by or under the direction of the electrical utility company. NOTICE: Installation of the System may require(i)drilling into various parts of the Home,and(ii)other interior or exterior work that may require access to non-visible areas. The Customer consents to the installation work described. 3. Total Price. The Customer agrees to pay the Company the Total Price in exchange for the System, on the payment terms shown above, and further agrees as follows: a. Change Orders/Extra Work. If the Customer, the Customer's agent or representative, or any governmental agency requires any changes to the System beyond what is initially agreed to by the Company,the cost for any such change will be added to the Total Price, and the term "Total Price" as used in this Agreement will mean the adjusted higher Total Price. The cost of any such change order will include direct labor, materials, subcontracts plus supervision, general conditions, overhead, and profit.The Customer will also be required to pay all expenses incurred by the Company because of unanticipated or unforeseen circumstances (such as a faulty roof or inadequate electric service). b. Cost Increases.Customer acknowledges that the System equipment and materials the Company will furnish and install are subject to cost increases. The Company will hold the Total Price for six months after execution of this Agreement or the date of the last signed amendment to this Agreement. After six months, if the cost of any equipment or material rises by any unusual amount because of circumstances beyond Company's control, including but not limited to market price fluctuations or a site audit that reveals the need for additional materials or labor,then the Company will have the right to present Customer with a change order for the with a new Total Price. Customer will have the right to accept or reject this new Total Price.If Customer does not accept the new Total Price, this Agreement will terminate and the Company will provide the Customer with a full refund of any amounts previously paid, and the parties will have no further obligations to one another. c. Ownership/Security Interest. Until the time that the Customer has paid Company the entire Total Price, the Customer grants the Company and its agents, employees, and representatives the right to enter the Home/property and remove the System in whole or in part.The Customer agrees the System are not a fixture but will remain personal property at all times until the entire Total Price has been paid to the Company. Ownership of the System will remain with the Company until the Customer has timely paid the full Total Price. To the extent the Customer may be considered the owner of the System, however, the Customer grants the Company a security interest in the System to secure payment of the Total Price and any other amounts due under this Agreement, and grants the.Company the maximum rights available under applicable law in enforcing that security interest. The Company also may assert all rights under applicable state law relating to contractor/mechanic liens on real property, with respect to the Home and the Customer's property. 2 Don ID. h57dnhdnh73fr:65frdn2544(1113h037d7fd15hdp4d 41fr 4. Contractor Registration. Pursuant to Mass. Gen. Laws c. 142A§ 1, et seq. all contractors and subcontractors performing residential contracting services must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. 5. Notice of Possible Mechanic's Lien.The undersigned Contractor(the Company)is about to perform work and/or furnish materials for the construction, erection, alteration, or repair upon the Customer's land at the address shown above under a Contract with the Customer. This is a notice that the undersigned Company and any other person(s) who provide(s) labor and materials for the improvements to the Customer's property under contract with the undersigned Company may file a mechanic's lien upon the land in the event of non-payment to them. It is the Customer's responsibility to assure themselves that those other persons under contract with the undersigned Company receive payment for their work performed and materials furnished for the construction, erection, alteration, or repair upon the land 6. Late Fees. The Customer must pay the Company a late fee of $150.00 on any late payment. A payment is considered a late payment if the payment is not received by the Company on or before the due date. 7. Interest on Overdue Payments. Any amount not paid when due will bear interest at the rate of 12% annually, beginning on the date that is 30 days after the due date. 8. Manufacturer Warranty.The manufacturer of the Solar Equipment and any associated components may provide a manufacturer's warranty. All warranties can be obtained by the Customer directly from the manufacturer and any claims for a manufacturer defect must be directed to the manufacturer and not the Company.The Company may assist the Customer in identifying any applicable manufacturer's warranty(ies) solely as a courtesy. THE COMPANY PROVIDES NO ADDITIONAL WARRANTY RELATING TO THE SOLAR EQUIPMENT, OTHER THAN THE LIMITED LABOR WARRANTY DESCRIBED IN THE NEXT SECTION BELOW.To the extent products, equipment, systems, or materials incorporated into the Work are specified and purchased by Customer, they shall be covered exclusively by the warranty of the manufacturer. There are no warranties that extend beyond the description of the face of any such warranty. For such incorporated items, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. 9. Labor Warranty. The Company guarantees that the System will be free from installation defects for a period of ten years following the conclusion of onsite installation (the"Labor Warranty").This Labor Warranty does not cover any of the following: natural acts such as storms, winds, rain, or snow; damage covered or normally covered by homeowner's insurance such as falling tree branches, power outages, power surges; normal wear and tear of the roof, roof shingle failure, sub-structure failure,or siding or electrical system failures.The Labor Warranty also does not cover any damages caused by animals or by improper maintenance of the structure or the system or by any action of any person other than the Company. If the Customer discovers an installation defect within the Labor Warranty period, the Customer must immediately notify the Company in writing describing the nature of the defect. If the Company determines that the defect is due to defective workmanship on the part of the Company during installation,the Company will correct the defect at no additional charge to the Customer. If a part repair or replacement is required and is covered by the manufacturer's warranty, the Customer must first obtain warranty coverage from the manufacturer and only then will the Company remedy the workmanship defect. Customer will be responsible for all costs of all repairs and replacements not expressly covered by this Labor Warranty. 10. Roof Warranty. The Company, for a period of three years, warrants that, with respect to all roof penetrations made by the Company, such roof penetrations will be free from material defects in workmanship and will, be sealed or flashed to eliminate any liquid or vapor penetration, and that such roof penetrations will not affect or otherwise diminish the strength, integrity, water-repelling or balance of any underlying roof structure. 11. Customer Responsibilities. The Customer agrees to provide the following in order to aid the Company in completing the System(any reference to the"Company"in this section also includes the Company's agents,employees, representatives, and subcontractors): a. The Customer must identify and stake any concealed pipes, conduits, utilities,or other equipment before the Company begins work on the System (the Customer agrees that the Customer is responsible for any damage caused to or by any concealed pipes, conduits, utilities not identified and staked as required); 3 r)nr. In h57ric:hrlc:hnfnF5frrin2.541183hU37r17fri 15ihde4ci 41ff b. Inform the Company of any rules, regulations, restrictions, or covenants covering the Home that may impact the design and installation of the System; c. The Customer must prepare and implement a stormwater pollution and prevention plan if such a plan is required by any government agency; d. The Customer must provide prompt decision making to the Company regarding unspecified construction plans, designs, or specifications relating to the System; e. The Customer must make sure the Home is prepared for local government (city/county/town) inspection at the time of completion of the System; f. The Customer must cure any pre-existing code violations at the Home that relate in any way to the System; g. The Customer must grant and obtain all permissions require for the Company to connect the System to required utilities at the Home; and h. The Customer must make water and electrical utility services available to the Company for use in carrying out the Company's work; i. The Customer must make the Home and property available to the Company without interruption during the Company's normal working hours to permit completion of installation work. 11. Property Conditions. Customer will be responsible for the structural integrity of the location where the System are installed, including structural or electrical modifications necessary to prepare the Home for the System. The Company is not responsible for any known or unknown property conditions.The Company is not responsible and bears no liability for the malfunctioning of existing electrical equipment at the Home, including but not limited to the main electrical service panel, any major electrical devices, or any other fuses or similar devices. 12. Rebates/Incentives. Depending on the state and utility district in which Customer resides, Customer may be eligible for various state and local rebates and incentives. The rebate and incentive calculations the Company provides to Customer are estimates only. These estimates are based on certain assumptions that may not be applicable based on the circumstances specific to the System. However, actual rebates and incentives are variable as eligibility requirements, funding availability and rates may change. In an effort to assist Customer in capturing its rebate, the Company will use good faith reasonable efforts to help Customer secure applicable rebates and incentives, but the Company will have no financial obligation to Customer regarding actual rebate and incentive amounts received. Customer agrees to pay the Total Price in full regardless of the actual amount of rebates and/or incentives Customer receive. 13. Return of Goods/Equipment. If the Customer cancels this Agreement, the Customer agrees to make all goods and equipment received from the Company available to the Company for pickup by the Company, or delivery back to the Company by mail or other courier service. If the Customer cancels this Agreement at any time that is more than three business days after the date of execution, for any reason other than that the Company deems the Home not suitable for the System, then the Customer will be required to pay the Company a cancellation fee equal to$3,000.00, in recognition of the fact that the Company will immediately incur costs relating to the design and installation of the System. The Company will pay for or reimburse the Customer for any mailing/delivery expenses relating to return of the goods and equipment. The goods and equipment must be in the same condition and form as they were when first provided by the Company to the Customer. 14. Privacy/Publicity. Customer grants the Company the right to publicly use, display, share, and advertise the photographic images, project details, price and any other non-personally identifying information of Customer's project. The Company will not knowingly release any personally identifiable information about Customer or any data associating Customer with the project location. Customer may opt-out of these publicity rights by giving the Company written notice and mailing it to the Company's address on the first page of these Terms and Conditions. 15. Default/Remedies. The failure of the Customer or the Company to comply with any term in this Agreement will constitute a material default, meaning a significant breach of this Agreement. Upon default by the Customer, the Company may immediately stop all work on the System, and the Company will have all rights and remedies available under this Agreement or available at law or in equity, all such rights and remedies being cumulative and non-exclusive. 4 lnr. In. h57dr.hcirh7ifr.Fi5frcin254ciR;ihn37di7fri 15hrla4r1 41/r Upon default by the Company, the Customer must provide the Company with written notice, and the Company will then have 28 days in which to cure or commence the cure of the default. If the Company does not timely cure or commence cure of a default within that 28-day period,then the Customer's exclusive remedy will be to deduct the resulting damages to the Customer from the Total Price. EACH PARTY'S LIABILITY TO THE OTHER UNDER THIS AGREEMENT IS LIMITED TO DIRECT, ACTUAL DAMAGES ONLY. BOTH PARTIES AGREE THAT IN NO EVENT SHALL THE COMPANY BE LIABLE TO THE CUSTOMER FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE, EXEMPLARY, SPECIAL OR INDIRECT DAMAGES. The Company's liability to the Customer shall not exceed the Total Price, including without limitation, damages to the Home or property during the performance of installation or resulting from the System.Without limiting any of that, the parties clarify that upon termination of this Agreement by the Company for reason of Customer's default, the Company may remove any System materials or equipment from the Home, and submit to credit reporting agencies (credit bureaus) negative credit reports that would be reflected on Customer's credit record. 16. Unforeseen Conditions. The Company is not responsible for failures, delays or expenses related to unanticipated, unusual, or unforeseen conditions at the Home arising out of conditions beyond Company's reasonable control (all of which shall be considered "Force Majeure Events"). Performance times under this Agreement will be considered extended for a period of time equivalent to the time lost due to such conditions. If Company discovers unforeseen conditions requiring additional cost, then Company will present such costs to Customer and get Customer's written approval before beginning or continuing performance. If the Customer does not approve, the Company may terminate this Agreement. 17. Entire Agreement. This Agreement contains the entire agreement between the Customer and the Company relating to the subject matter addressed. No sales representative has the authority to add, delete, or modify the typed terms of this Agreement, either in writing or verbally. 18. Binding Effects/Assignment. This Agreement is binding upon and inures to the benefit of the parties and their respective heirs, legal representatives, successors and assigns.The Customer may not assign its rights or delegate its obligations under this Agreement. Any assignment or delegation by the Customer is void, meaning ineffective. The Company may assign its rights and delegate its duties under this Agreement at any time in the Company's sole discretion. 19. Attorney's Fees. In any action arising out of this Agreement, the prevailing party is entitled to costs and reasonable attorneys' fees from the non-prevailing party. 20. Risk of Loss. All risk of loss or damage to the Solar Equipment will be borne by the Customer from the moment any such Solar Equipment arrives at the Home, unless the loss or damage is caused by the negligent, reckless, or intentional acts of the Company. 21. Counterparts; Signatures. This Agreement may be executed in multiple counterparts, each of which will be deemed an original, and all of which when taken together shall constitute one and the same document and agreement. A copy or electronic transmission of any part of this Agreement, including the signature page, and any electronic signature on this Agreement or electronic copy of this Agreement will have the same force and effect as an original. 22. Indemnification. Both Parties shall indemnify, defend and hold harmless the other and its employees, officers, directors, agents and assigns from any and all third party claims, actions, costs, expenses (including reasonable attorneys' fees and expenses), damages, liabilities, penalties, losses, obligations, demands for injury to persons, including death, or damage to property, to the extent caused by the negligence or willful misconduct of the indemnifying party. 23. Governing Law. To the fullest extent possible, this Agreement will be governed by, and construed and enforced in accordance with, the laws of the state in which the Home is located, without regard to any conflicts of law issues. 24. Dispute Resolution. If the Parties cannot reach a resolution on a matter relating to or arising out of this Agreement, the Parties shall endeavor to reach resolution through good faith direct discussions between the Parties. If the Parties are not able to resolve such matter within thirty (30) days from the date of the first discussion, the Parties shall submit such matter to the following dispute resolution procedures: 5 f)nr: In. h.57cichcinhnfr65fr in254dR3h(l37ci7frll5hrla4r1 41/T a. If direct discussions pursuant to Section 27 above do not result in resolution of the matter,the Parties shall endeavor to resolve the matter by private, non-binding mediation. To the extent practicable, the mediation shall be convened within thirty (30) days of a party's demand for mediation, and shall conclude within forty-five (45) days of a party's demand for mediation. The cost of mediation shall be shared equally by the Parties. b. If the matter is unresolved after submission of the matter to mediation, the dispute shall be subject to litigation in the Superior Court in Massachusetts serving the area in which the Home is located. The Parties further agree that such the said Superior Court in Massachusetts shall have jurisdiction over each of them, and is the appropriate venue for the determination of such disputes. c. If either party to this Contract shall seek to enforce this Contract, or any duties or obligations arising out of this Contract, against the other party to this Contract, by legal or equitable proceedings, then the prevailing party in such proceedings shall receive, in addition to all other rights and remedies to which such party is entitled, such party's reasonable costs and expenses incurred in such proceedings, including reasonable attorney's fees. For purposes of this Subsection, a prevailing party is defined, to the extent applicable: (1) as a party that is awarded a net fifty-one percent (51%) of its affirmative claims, after any offsets for claim(s) or counterclaim(s) by the other party, and (2) as a party against whom an award of less than fifty percent (50%) of the opposing party's claim is granted 25. Insurance. The Customer agrees to maintain and keep in full force, during the installation of the System and up through and including final payment, property damage insurance that covers the full insurable value of the Home. The Parties hereby discharge and release each other for or on account of any and all claims and liabilities arising out of any loss or damage to any property caused by such risks as are covered by insurance and the Parties shall properly notify their respective insurance carriers that each has waived subrogation rights against the other such that the waiver is binding upon said carrier. 26. State Specific Laws. Attached hereto may be a state specific addendum/notice containing additional terms, conditions, disclosures, and/or notices, specific to the laws of the State in which the Home is located. If attached, the state specific addendum is incorporated into this Agreement by this reference. If anything in the state specific addendum conflicts with these Terms and Conditions, the provisions in the State Specific Addendum will prevail. [End of Terms and Conditions] 6 nor. In h57dncrirh7Rfr.65frrdO754riR:ih0:17ri7fr115hrie4rl Notice of Cancellation 09 /02 / 2022 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (100 BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OB IGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN HE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 09/07 , 20 22 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: 7 flnr.ID. h.57c1c:hclrh7lfr:65frci0254dR3hfl 7c17fc11 ShrIA4d1 Notice of Cancellation 09/02/2022 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN THE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 09/07 , 20 22 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: 8 Doe:ID. h.57cinhrinhrifrA5frcl025411R3h037d7fc115hrIA4c1 V HELLOSIGN Audit Trail TITLE MA Solar Install Agreement FILE NAME MA Solar Install Agreement(1).pdf and 1 other DOCUMENT ID b57dcbdcb73fc65fcd0254d83b037d7fd15bde4d AUDIT TRAIL DATE FORMAT MM/DD/YYYY STATUS • Signed Document History 09/02/2022 Sent for signature to Ryan Severin (ryan.s@empowerenergy.co) SENT 20:20:34 UTC and Khahtee Turner(khahtee@studiocreativeplay.org)from esign@empowerenergy.co IP: 3.140.98.103 0 09/02 12022 Viewed by Ryan Severin (ryan.s@empowerenergy.co) VIEWED 20:20:48 UTC IP: 75.135.125.78 09/02/2022 Signed by Ryan Severin (ryan.s@empowerenergy.co) SIGNED 20:21:51 UTC IP: 75.135.125.78 00 09/02/2022 Viewed by Khahtee Turner(khahtee@studiocreativeplay.org) VIEWED 20:24:07 UTC IP: 73.89.160.120 09/02 1 2022 Signed by Khahtee Turner(khahtee@studiocreativeplay.org) SIGNED 20:25:11 UTC IP: 73.89.160.120 09/02/2022 The document has been completed. COMPLETED 20:25:11 UTC Powered by V HELLOSIGN