Loading...
29-111 (14) BP-2022-1516 596B RYAN RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 29-111-001 CITY OF NORTHAMPTON Permit: New Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1516 PERMISSION IS HEREBY GRANTED TO: Project# 2022 UNIT B NEW SFH Contractor: License: Est. Cost: 430000 013693 Const.Class: Exp.Date: 07/20/2023 Use Group: Owner: HOMES NU-WAY Lot Size (sq.ft.) Zoning: WSP Applicant: HOMES NU-WAY Applicant Address Phone: Insurance: 10 WHITE AVE EAST LONGMEADOW, MA 01028 ISSUED ON: 12/01/2022 TO PERFORM THE FOLLOWING WORK: NEW SINGLE FAMILY HOME POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: ALL, .' Fees Paid: $1,076.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Massachusetts oI Board of Building ReguCommonwealthlationsof and Standards FOR t3I Massachusetts State Building Code, 780 CMR MUNICIPALITY cv USE c\Building Permit Application To Construct, Repair, Renovate Or Demolish a Revised Mar 2011 One-or Two-Family Dwelling 0 Z This Section For Official Use Only Building Permit Number: 13e 2022-/y/ (v Date Ap lied: 11 1 �a iI 6r • _ Building Official(Print Name) Signature 1 to SECTION 1: SITE INFORMATION 1.1 Proper Addr 1.2 Asse so,r Map&Parcel Numbers 5/ h .29- oof 1.1 a Is this an acceptdd street?yes 5< no Map Number Parcel Number 1.3 o ng Information• 1.4 Proper imensions: :id_ Zoning District Proposed a Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 332 ' is'?"/ ,' ''Q ' 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record,:/ /J I'V 1J`wrq a�., /*Aft s ._ ,2C• E/9S% C tea.i✓1 e X r/1✓• fr1r ./4-� Name(Print) (/ City,State,ZIP l0 Lei ii `rt ,V'e (033 s 3-ocSS ✓uUW 4_./-�oM.S COS;y. / No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Constructiorj Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work': To ra vj'/g A S,'eC// [ 15444 i'Jy_ AZ0-).,Te 4/i'A A S 'AR+tp( D ie rGo r G 4 v,7'`) S - 6,// SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ , 3. 6 0 60, 1. Building Permit Fee: $ Indicate how fee is determined: / 0 Standard City/Town Application Fee 2. Electrical $ 30 D�— f 0 Total Project Cost' (Item 6)x multiplier x 3. Plumbing $ ,P 42:%'0 2. Other Fees: $ 4. Mechanical (HVAC) $ a S'cr D— List: 5. Mechanical (Fire $ Suppression) Total All Fees: $/O X.— w / Check Not Check Amount: /o76- Cash Amount: 6. Total Project Cost: S 7j CIJ(r El Paid in Full CI Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) i License Number Ex iration ate Name of CSL Holder List CSL Type(see below) /O /v 6/rc 19/-e No.and Street �T e Description l % Unrestricted(Buildings up to 35,000 cu.ft.) E/9 S L U'7WP g-/Za--' D�� R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering (yi3J WS Window and Siding o SF Solid Fuel Burning Appliances ��3 p6 gC /vUlll/V p-frke 5 Q�4,4'/,. I Insulation Telephone ' Email address Cdrjr D Demolition 5.2 Registered Home Improvement Contractor(HIC) HIC Registration Number xpiration Date HIC Company Name or HIC Regis ame No.and Street f Email address City/Town, State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provi.e this affidavit will result in the denial of the Issuance of the building pennit. Signed Affidavit Attached? Yes No . 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relat. o work authorized by this buildi g permit application. Print Owner' ame(Electronic Signature) 'Date SECTION 7b:OWNER'OR AUTHORIZE AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is fanned,provide the information below: Total floor area(sq.ft.) /b��..� (including garage,finished basement/att5s,decks or porch) Gross living area(sq. ft.) /g yr— Habitable room count Number of fireplaces (I) j{,-Trz%C Number of bedrooms 5/ Number of bathrooms 3 Number of half/baths 6 Type of heating system Ate-7)2'G Number of decks/porches / Type of cooling system C 77210/ Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD SIDE YARD SIDE YARD_ , Sc€ 7i--g;C fPf p 762- 7 FRONT SETBACK FRONTAGE MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Public Works Director Water Division 125 Locust Street Northampton,MA 01060 413-587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 596 RYAN ROAD,units A&B, FLORENCE Inquiry Made By: JOHN HANDZEL 413-563-0085 (Name) (Telephone Number) Date of Inquiry: 10/5/2022 Fire Line Irrigation Domestic X Number of Units: 2 Type of Units: Type of Ownership: Single Family X Private X Apartments Condo Multi-Family Rental Commercial (Applicant to fill out the above) Municipal Water Main in Front of Location: Yes X No Existing service to site? Yes X No Size of Water Main: 12 Material: Cast Iron Age: 1945 Approximate Static Street Pressure: 50 Flow Test Conducted: Yes No X (If flow test conducted attach results) Size of Service Connection: 1" Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320' - A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. -Arrangement of such installation shall be made with the Northampton Water Department within a minimum of 5 working days notification. -All work shall conform to Northampton Water Department specifications. Keith Snape 10/7/2022 (Water Superintendent) (Date) *Water Entry 2 ($1,250)Domestic *Meter $ 900 *Radio Read $300 (fee to be determined) (Includes fire line if required) cc: City of Northampton Building Dept./Commissioner Total for 2 = $3700.00 NOTE:If this availability is for new construction,it must be submitted electronically or mailed to the Building mailed to the Building Inspector MUNICIPAL SEWER AVAILABILITY APPLICATION Northampton Public Works Streets Division 125 Locust Street Northampton,MA 01060 413-587-1570 A Department of Public Works Trench Permit and Sewer Enhy Permit shall be required prior to any construction or connection activity associated with this application. Location: 596B RYAN ROAD, FLORENCE (i3) Date of Inquiry: 10/05/22 Inquirer with contact info: JOHN HANDZEL NU-WAY HOMES Reason for Request: NEW CONSTRUCTION For Office Use Only Below This Line Municipal Sewer Main in Front of Location: Yes X No Size of Sewer Main: 8" Material: AC Age: 1963 Depth of Sewer Main: 7' Length of Sewer Main: 300' Size of Service Connection: 6" Type of Service Connection: Reuse Service. Domestic Tie In: $1.250 Tie-in to Existing Sanitary Service: $1.250 Comments:Contractor must find existing service at property line. City Requires 6" cleanout installed at City Property Line •angements of such installation shall be made with the Northampton Streets Division with a nil Brendan Shea Date: 10/12/2022 Sewer Foreman *Sewer Entry$ /4:2 5d Ud *Fees will be charged based on current fee structure at the time of entry application If this availability is for new construction.it must be submitted electronically or mailed to the `I=' c` �R.� —oi; CITY OF NORTHAMPTON,MASSACHUSETTS t DEPARTMENT OF PUBLIC WORKS 1.; rt, ; E 125 Locust Street : " Northampton,MA 01060 413-587-1570 Donna LaScaleia Fax 413-587-1576 Director Permit No. D05-23 DRIVEWAY PERMIT Date: 10/4/2022 Check#: 11394 FEE: $250.00 Proposed driveway must be staked and address and/or lot number Posted Public Shade Trees are protected by MGL Chanter 87. Do not cut. trim or remove any trees on City property without the expressed written permission of the Tree Warden. The undersigned respectfully petitions The Department of Public Works for: A new Curb Cut Permission to install a driveway at: 596 RYAN ROAD,FLORENCE Fifteen(15)foot maximum width from street line to property line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. The first one hundred(100)feet of the driveway surface shall be paved as soon as possible if the grade of the proposed driveway exceeds 3%at any point in the first one hundred(100)feet.Homeowners will be held responsible for any costs to the City of Northampton in the event of a washout of this driveway. City is not responsible for culverts installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for private, individual driveways as most recently amended,must be followed. No excavation is authorized without a valid trench permit in addition to this permit. By: NU-WAY HOMES,INC John Handzel Telephone: 413-563-0085 Signature: Superintendent-Tree Warden Highway Superintendent Date Forestry,Parks&Cemetery Date Proposed Location&Tree MIKE ANTOSZ 10/12/22 RICH PARASILITI 10/5/22 Protection Inspections Gravel Base Grade Inspected Final Approval Director of Public Works Cc: Building Inspector (SUBJECT TO ATTACHED CONDITIONS 1 &2) I0I L? Permit No. D05-23 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections,any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By: Name: NU-WAY HOMES JOHN HANDZEL Address: 10 WHITE AVE,E. LONGMEADOW 413-563-0085 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants,a plan showing the proposed driveway with grades,locatio and Planning Board permits are required. Cc: Building Inspector i • • li Commonwealth of Massachusetts 1 Division of Professional Licensura Board of Building Regulations and Standards Cons�futstA Ipprvisor CS-013693 fpires:0712012023 JOHN M HANDZEL, 4. i 10 WHITE AVENUE 't •i -frY' EAST LONGMfAUOW v7A•'0102B, n Commissioner 'dada �. tC417U u. City of Northampton r• v Massachusetts e„ �., .1 ' DEPARTMENT OF BUILDING INSPECTIONS � �` �r 212 Main Street • Municipal Building ~y" Northampton, MA 01060 j'sfr a,.-‘_" CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number./ 4ini lec, is that all debris resulting from this work shall be disposed of in a licensed Waste disposal facility, as defined byMGL c 111, S 150A. properly p Y The debris will be disposed of in: Location of Facility: VS /` 4 9 09/ - /cCPC // The debris will be transported by: Name of Hauler: (13 k9v//:>2b5,-- z i Signature of Applicant Date: /0�-/�c��" l The Commonwealth of Massachusetts a y'P Department of Industrial Accidents C V�a �a 5 1 Congress Street,Suite 100 .;_74:_ ea, Boston,MA 02114-2017 ,. — tvww massgov/din 11 orkers'Compensation Insurance Affidavit:BuildersiContractorsfElectricians,Plumbers. 'to IUI h 11-kU'%rill THE PERMITi'IN(:AI hHORITY. Applicant Information �/ Please Print L ibh Name Iliustncsa(hgatnratf,�n Individual I: n/() -�� A to S/J7C' Address:/0 I,JJ- "7.-_/91h. City/StatefZip:E9$7- Z rpf. i �`g O/Q Plane#: (V/3,.563 --0U?..5— Areyaa A eatptwer'!'beck the appropriate but: Type of project(required): LEI I am a cmplos er'a oh employccs(full and or part-time!.' ? flletlo11l 21 1 am a sole pc-opt ich r or pcutncrshrp and have no employers working fur rile in . CI Remodeling any eapacrls.[No workers'comp.insurance n.-quucvl.) 30 I am a lu,ne-crwner doing all work myself.[Nu wort.eT].comp.trnuran,c n-qurred.l` 9. 0 Demolition 10 Q Building additio 4.0 I am a honk n lien and w ill b.hiring ctirntractur to conduct all work on my property_ I w ill ensure that all contractors either has a murky&compensation insurance u an sole I 1.0 Electrical repairs or additions pruprietons with its employees. 12.0 Plumbing repair's or additions 50 I an,a general contractor and 1 line hired the soh-contraeton listed on the attached sheca. 130 Roof repairs I hese sub-contractors terse employees arid hale w miters'cony.insurance., 7261 -c a K a cwpx,ratouu and on officers have exernscd[rein right ofexemptun per SKil.L. 14.00ther I5 t 1141.and we liaise no employees.[No w orkers'comp insurance required.j *Any applwat that checks km=I must also fill out the mxtiun below hbohing them workers'compensation policy inforrattirm. f 13onwownen.who submit this affidavit incluaamrg they are doing all work and then hue outside contractors must submit a new alt,das It urtcl]irtrne%ueh kContractun that check this!tins must attaciaed an additional shcet show inn tlw Warne of fire sub-contactors and state whether or n.t tl,o,+c ertutres has c employees. If the sub-contractors Fuse canplonees.!hey must pros id,:their workers;comp.policy number. r. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins.Lic.#: Expiration Date: Job Site Address: CitytStateiZip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to S I.500.00 andfor one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to S250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cehify n r the pains and allies of erjurt•that the information provided above is true and correct. Signature: / °It Dale_ //� l aZ iui:,,n, : (fr,3),s'6 ; -Vt78' tlflit id use only. Do not write In this area,to be completed by city or town ofcial ( it7, or Torn: Permit/License# Issuing.Authority (circle one): I. Board of Health 2.Building Department 3.('it)(fossil Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ACCORD CERTIFICATE OF LIABILITY INSURANCE DATE(MM,DDlYYYY) 11/16/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Paula Belisle NAME: Crimmins-Graveline Insurance PHONE (413)283-8378 FAX (413)283-2556 (A/C,No,Ext): (A/C,No): 1382 Main Street E-MAIL pbelisle ins.corn ADDRESS: @� P.O.Box 905 INSURER(S)AFFORDING COVERAGE NAIC k Palmer MA 01069 INSURERA: James River Insurance Company 12203 INSURED INSURER B: Nu-Way Homes Inc INSURER C: 10 White Avenue INSURER D: INSURER E: East Longmeadow MA 01028 INSURER F: COVERAGES CERTIFICATE NUMBER: 2022 GL REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DDIYYYY) (MM/DDIYYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1.000,000 CLAIMS-MADE DAMAGE TO RENTED 100,000 Xl PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 A 000840844 08/06/2022 08/06/2023 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2.000,000 POLICY PEt° LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER S AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS AIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) $ UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION $ $ WORKERS COMPENSATION PER OTH- STATUTE ER AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) RE:596 A Ryan Rd Northampton,MA 01060 596 B Ryan Rd Northampton,MA 01060 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN City of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. Building Dept AUTHORIZED REPRESENTATIVE 212 Main Street y//� _ �([s Northampton MA 01060 g�%�ief v @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD City of Northampton P/ Massachusetts �' ' _ *� k DEPARTMENT OF BUILDING INSPECTIONS li ,i ',IF � ,' 212 Main Street • Municipal Building --. Northampton, MA 01060 i Fee Calculator for New Residential Construction ONLY Location : 5? g ,y,,,,, eZ( Square Footage Amount Basement @ .20 1ST Floor @ .50 �G O ,3-440— 2nd Floor @ .50 /1r5 ra -' '/2 Floors, Finish Attic, Garage @ .20 .5-ic 1/6 Deck / Porches @ .20 / Z- 31, /W Total : " .7L -gam c ' 3 ilpyr4,4-1 i&ifl Home Energy Rating Certificate Rating Date: 2022-10-19 Projected Report Registry ID: Based on Plans Ekotrope ID: j2rGpo8L HERS® Index Score: Annual Savings Home: 5 2. Your home's HERS score is a relative Ryar r. , performance score.The lower the number, 1 I9INorthampton, MA 01062 the more energy efficient the home.To Builder: learn more, visit www.hersindex.com *Relative to an average U.S.home John Handzel -Nu-Way Homes Inc Your Home's Estimated Energy Use: This home meets or exceeds the Use [MBtu] Annual Cost criteria of the following: Heating 22.0 $516 2018 International Energy Conservation Code Cooling 0.5 $12 2015 International Energy Conservation Code Hot Water 2.7 $63 Lights/Appliances 19.4 $454 Service Charges $60 Generation (e.g.Solar) 0.0 $0 Total: 44.6 $1,105 HERS Index Home Feature Summary: Rating Completed by: .--g-w Home Type: Single family detached ISOModel: John Handzel Custom Energy Rater. Paul DellaTorre EM lstmg 140 Community: Northampton RESNET ID 8776762 Homes ISO Conditioned Floor Area: 1,915 ft2 Rating Company: Energy Compliance Services "O Number of Bedrooms: 4 27 Hudson Dr.Southwick MA 01077 Reference 1i. Primary Heating System: Air Source Heat Pump•Electric• 11 HSPF 413-427-2423 MOB 100 PrimaryCoolingSystem: Air Source Heat Pump Electric• 18 SEER ,� Y p• Rating Provider. Building Efficiency Resources w Primary Water Heating: Residential Water Heater•Electric•3.75 Energy Factor PO Box 1769 Brevard,NC 28712 ro House Tightness: 3 ACH50 800-399-9620 ....... i0 Ventilation: 70 CFM••9 Watts - 4st' w_ a Duct Leakage to Outside: Forced Air Ductless .1____, _-- 7 w Above Grade Walls: R-23 , • w Ceiling: Attic,R-60 `•"•"".� iia Window Type: U-Value:0.3,SHbt:U.31 Ail i Della rtile Zero e� 0 Foundation Walls: N/A Paul DellaTorre,Certified Energy Rater 111P" ""Emory Framed Floor: R-30 Digitally signed: 10/19./22 at 11:12 AM I e kot ro a Ekotrope RATER-Version:4.023011 p The Energy Rating Disclosure for this home is available from the Approved Rating Provider. This report does not constitute any warranty or guarantee. Home Energy Rating Certificate Rating Date: 2022-10-19 Projected Report Registry ID: Based on Plans Ekotrope ID: j2rGpo8L HERS® Index Score: Annual Savings Home: 52 Your home's HERS score is a relative 596-B Ryan Rd 1 performance score.The lower the number, the more energy efficient the home.To 5 1 5 Northampton, MA 01062 Builder: learn more, visit www.hersindex.com *Relative to an average U.S.home John Handzel -Nu-Way Homes Inc Your Home's Estimated Energy Use: This home meets or exceeds the Use [MBtuI Annual Cost criteria of the following: Heating 21.1 $495 2018 International Energy Conservation Code Cooling 0.6 $13 2015 International Energy Conservation Code Hot Water 2.7 $63 Lights/Appliances 19.3 $453 Service Charges $60 Generation (e.g. Solar) 0.0 $0 Total: 43.7 $1,084 HERS Index Home Feature Summary: Rating Completed by: 411b. ..-“.,*, Home Type: Single family detached Model: John Handzel Custom Energy Rater. Paul DellaTorre ISO Exist mg Ito Community: Northampton RESNET ID: 8776762 Homes 1so Conditioned Floor Area: 1,915 ft2 Rating Company: Energy Compliance Services 1O Number of Bedrooms: 4 27 Hudson Dr.Southwick MA 01077 Reference r Primary Heating System: Air Source Heat Pump•Electric•11 HSPF 413 427-2423 Home 100 w Primary Cooling System: Air Source Heat Pump•Electric•18 SEER Rating Provider: Building Efficiency Resources so Primary Water Heating: Residential Water Heater•Electric•3.75 Energy Factor PO Box 1769 Brevard,NC 28712 n House Tightness: 3 ACH50 800-399-9620 "°•'•"•r �A Ventilation: 70 CFM•9 Watts ; �', *0 This Howe Duct Leakage to Outside: Forced Air Ductless w Above Grade Walls: R-23 b 20 Ceiling: Attic,R-60 //ll T • �`°"""� MU(�� Window Type: U-Vafue.0.3.SHGC.0.31 -- zero EHorne nergy 0 Foundation Walls: NIA Paul DellaTorre,Certified Energy Rater c...iMen Framed Floor: R-30 Digitally signed:10/19/22 at 11:12 AM CIC,1.1Y4, e kot ro a Ekotrope RATER-Version:4.0.23011 p The Energy Rating Disclosure for this home is available from the Approved Rating Provider Energy savings calculated without modifications to the energy model.(As Modeled) This report does not constitute any warranty or guarantee. 596-B R an Rd Northam•ton M. , HERS"Index Score: Rating Date: Oct 19,2022 52 HERS Registry ID: Annual Estimates: Rating Company: Electric(kWh): 12,797.2 Energy Compliance Services CO2(Tons): 8 2 Rating Provider: Building Efficiency Resources Approx.Energy Cost: $1,084 Rating Provider Address: PO Box 1769 Brevard,NC 28712 HERS Index Home Feature Summary: ' ,,,,tom n Single family detached,4 bedrooms,1,915t ft2 (*htkK „• Heating: 11 HSPFMonie' "0 Cooling: 18 SEER 11, r '�. f • Re e e 100 n .e r ea e . r 4: . Ventilation:70 CFM•9 W Duct LTO:Forced Air Ductless Above Grade Walls:R-23 This Home I _! Ceiling:Attic,R-60 l Window:U:0.3•SHGC 0.31 I IPro Ennorne ergy ' 0 Foundation Walls:NJA Ehotrope RATER-Version: I ekotrope 4.0.23011 This report does not constitute arty warranty or guarantee IECC 2018 Performance Compliance Property Organization Inspection Status 596-3 Ryan Rd Energy Compliance Servic Results are projected Northampton. MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northampton Builder John Handzel -Nu-Way 0391_John Handzel 596-B Ryan Homes Inc Rd_Northampton_221019 This report .s basal on a proposed design and does no, conf:rm field enforcement of design elements. Annual Energy Cost Design ;ECC 2018 Performance As Designed Heating $886 $91, Cooling Sb9 $51 Water Heating $123 $123 Mechanical i entilation $52 $12 SubTotal -Used to determine compliance $1,129 $1,103 Lights &Appliances w/out Ventilation $822 5822 Onsite generation $0 SO Total $1,952 $1,926 R405.3 Source Energy Exception: The proposed home uses 1.92 MBtu LESS source energy than the reference home. Requirements R405.3 Performance-based compliance passes by 2 3°ro The proposed house meets the IECC 2..18 Pet i^rm:nce re, re„ce e-ergy b., requ-rement by S23.13 tt.y2 wtBtu;. ® R402 4.1 2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa It must not exceed 3 00 A H at 50 Pa ® R402.5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 31. .be ma mum allowed value is No Limit]. • R402 5 Area-weighted average fenestration U-Factor • R404.1 Lighting Equipment At least 90 0%of fixtures shall be high-efficac, lamps.curre'tl. 100.0°4)are high- efficacy ▪ R403 6.1 Mechanical Ventilation Efficacy e Mandatory Checklist Mandatory code requirements that are not 2018 IECC Mandatory Checklist must be checked as corn te. checked by Ekotrope must be met e IRC M1505 4 3 Mechanical Ventilation Rate R405.2 Duct Insulation All ducts outside the thermal envelope must be insulated to at least R6 0 Design exceeds requirements for IECC 2018 Performance compliance by 2.3%. As a 3rd party extension of the code junsdiction utilizing these reports.I certify that this energy code compliance document has been created in accordan with the requirements of Chapter 4 of the adopted international Energy Conservation Code based on HAMPSHIRE County If rating is Projected I certify that the building design de abed herein is consistent ..ith t..e building pans. specifications. and other caic cations submitted with the permit application ,f rating is Confirmed I certify that t e address re erenced above has been inspected,tested and that the mandatory pro"isions of the IECC have been installed to meet or exceed the intent of the itCC or will-e verified as such b'•a other party Name: Paul DellaTorre Signature: %)e& )r' Organization: Energy Compliance Services Digitally signed: 10/19/22 at 1 :12 AM Ekotrope RATER-Version 4.0.2.3011 IECC 018 Per o.r,a i.e i.onipliauce,evurts<a,.ulateo using EKot.ope RAI ER s ene gy and code crmpl a'gorithm EKo.,ope RATER is a,.EsNE i Accre..ited HE...;Rahn i Tcoi All results are based on data entered by EI otrope users E.otrope disclaims aft lia.ii,t for the in,ormation shown on this report IECC 2018 Building UA Compliance Property Organization Inspection Status 596-B Ryan Rd Energy Compliance Servic Results are projected Northampton. MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northampton Builder John Handzel -Nu-Way 0391 John Handzel_596-B Ryan Homes Inc Rd_Northampton_221019 This report is based on a proposed design and does not confirm field enforcement of design elements. Building UA Elements IECC Reference As Designed Ceilings 35.9 25.4 Above-Grade Walls 111.6 103.7 Windows, Doors and Skylights 105.4 99.8 Slab Floor: 43.9 43.9 Framed Floors 20.6 23.2 Foundation Walls 0.0 0.0 Rim Joists 4.3 3.4 Overall UA(Design must be equal or lower): 321.7 299.4 Requirements e R402 1.5 Total UA alternative compliance passes by 6 9?-0. The proposed home meets the UA requirement by 6 9% Q 402 3 2 Glazed Fenestration SHGC © R402 4.1 2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa It must not exceed 3 00 A H at 50 Pa. e R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 31 The ma mum allowed value is [No Limit) e R402.5 Area-weighted average fenestration U-Factor e R404 1 Lighting Equipment At least 90 0%of fixtures shall be high-efficacy lamps.curve tly 100 0%are high- efficacy ee R403 6.1 Mechanical Ventilation Efficacy e Mandatory Checklist Mandatory code requirements that are not 2018 IECC Mandatory Checklist must be checked as compl to checked by Ekotrope must be met e IRC M1505 4.3 Mechanical Ventilation Rate • R403 3 4 Duct Leakage Testing eR403 5 3 Hot water pipe insulation Hot water pipes at least 3/4 in diameter must be insulated to R-3 at minimum Design exceeds requirements for IECC 2018 Prescriptive compliance by 6.9%. Name: Paul DellaTorre Signature: Pain Oefrei r te Organization: Energy Compliance Services Digitally signed: 10/19/22 at 11:12 AM Ekotrope RATER-Version 4.0.2.3011 IECC 2018 Prescriptive compliance results calculated using Ekotrope RATE:s energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims alt liability for the information shown on this report • • •..• 11,..44••;•••••••••'•jf••••••• � ••;••••••••••j j•••••. ' •j•••••••••••;••i••.• ..jjf••.•.;ji•'•• lj•;j••••••.j•f•••. • • ••• . •••••,•••••' , l •••• ••••••• •.f .tr.►f•• ••'••.• •• •f•1/.►►••ff•,f.•••••••.. i. ••• •••► • .s.so.�•� .;• •f••'rf••••f.rff. �ff!••fff• ••• f�.if .• v v - c-:: ) t :::„. .:... ... : •-- _ ..:: 596-BRyan Rd . --• Northampton, . ... MA 01062 Builder: John Handzel -Nu-Way Homes Inc Model: John Handzel Custom Community: Northampton •= •- This report is :,ased on a proposed design and does not confirm field enforcement of design elements.• : f': ) (•::tis THIS HOME IS CERTIFIED TO MEET THE _• : 2018 INTERNATIONAL ENERGY CONSERVATION CODE Building Features - Ceiling Attic, R-60 Duct Supply R-6.0. Return R-6.0 Above Grade Walls R-23 Duct .-ea age to Outside Forced Air Ductless •• • Foundation Walls N/A Total Duct Leakage 'Jntested - Framed Floor R-30 Heating Air Source Heat Pump • Electric • 11 HSPF ' •.= > Slab R-10.0 Perimeter. R-0.0 Cooling Air Source Heat Pump • Electric • 18 SEER ` ' Under :: • - Infiltration 3 ACH50 Water Heating Residential Water Heater • Electric • 3.75 Energy Factor :• Window U-Value: 0.3, SHGC: 0.31 • - As a 3rd part• y extension of the code tunsdicticn utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of _ .. Chapter 4 of the adopted International Energy Conservation Code based on HAIAPSHIRE County If rating is Protected I certify that the building design described herein is consistent with r f the building plans specifications.and other calculations submitted•:ith the permit application If rating is Confirmed. I certify that the address referenced above has been mspectedlested - and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party •• Name: Paul DellaTorre Signature: Pau(%)e/fa T6)ice Organization: Energy-Compliance Services Digitally signed__ 10119/22 at 11:12AM_ •• • Ekotrope RATER-Version 4.0.2.3011 ••• • 2018IECC compliance results calculated using Ekotrope RATER s energy and code compliance algorithm % Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users -- f�:•) Ekotrope disclaims all lie ii t for the informatior sh o',.n in this report , :.'• ►• .. f• •• •• •f •/ ►• .. •t •► • •• • •• •I II .. ••• •.0•. t.,•. • ••• •••. • _••••.`••••, • ••••/r1.••f_ • •,f•..1,•r•. •••• .••••%•f••. • ••••ft •••• .• ••••/1 !•i'...:'.. • 11 •••••••••f.••••••' r*••••••••'•f'f f•• •. .• f.••'•f•f••• •. .• ••••'ff••••• •. •• ♦••• H ••f• •. •• ••••••.•'••r• •• v •• •••• ff•• •. .1 ..•.•.i . IECC 2018 Label 596-B Ryan Rd Model: John Handzel Custom Ekotrope RATER-Version: 4.0.2.3011 Ceiling: R-60 Above Grade Walls: R-23 Foundation Walls: N/A Exposed Floor: R-30 Slab: R-10 Infiltration: 3 ACH50 Duct Insulation: N/A Duct Lkg to Outdoors: Forced Air Ductless U-Value: 0.3. SHGC: 0.31 Door: R-6 Median merit S Heating:Air Source Heat Pump • Electric • 11 HSPF Cooling:Air Source Heat Pump • Electric - 1 b SEER Hot Water: Residential Water Heater• Electric• 3.75 Energy Factor Average Mechanical Ventilation: 70 CFM Signature: