Loading...
42-032 (4) BP-2022-1421 755 WESTHAMPTON RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-032-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2022-1421 PERMISSION IS HEREBY GRANTED TO: Project# WOOD INSERT Contractor: License: Est. Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 Use Group: Owner: DAVID GIESE Lot Size (sq.ft.) Zoning: WSP Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON: 11/02/2022 TO PERFORM THE FOLLOWING WORK: WOOD STOVE INSERT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature:g I. • 1' . 21 • If Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner City of Northampton SHfla+_) /; -- _ Massachusetts r .1. ''c '� -'*R S, DEPARTMENT OF BUILDING INSPECTIONS .1. et, ;: �' 212 Main Street • Municipal Building U. :'b vj p p Northampton, MA 01060 ssi ti.;t APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: 2AV/r7 C/ 5cz Address: -JSS 4/-5�Ai<ruin iirn g Cacencc A/10 (No.) (Street Address) Phone: i/<3 q' 7- 7Go? Email: Owners Signature: Date: i 1 91� Contractor's Information (If Applicable) Name: 2 ovflis L 91712,,c 1`iz ii--/c ?%mcc Phone: V 3 3 7-7 3%/6 Construction Supervisor's License #: 9'?*V0( Expiration: /-6 -2y Home Impr. Contractor License #: / fa'T7 Expiration: //-)'t ' Stove Information Type of Fuel (check all that apply): Wood "( Pellet Coal 1 Location: sirs //,or Freestanding Insert Manufacturer: �ee/Fk rher7/ Model: /G - /✓L-0 /rl5'drr /. 5 /ri nq 4 All5 r 5 ` • Z r/►,-� i'7r0 -170C FOR BUILD1T G DEPARTMENT USE ONLY------___-__-___________ Permit# bP- ' 1/3/ Date Applied: I I- 1-21:1Z Z //,, Total all Fees: $ %Q C'/• `5 1 Building Official: 4%,-) ` Date Issued: I I Z- %Z (Print) //? Signature of Building Official: k ...... a..v .al...........r....$4.4, VI/ i..c..vu ..r...v...w n�`-' Department of Industrial Accidents t'.`.' _ ,_L-, Office of Investigations > :r :;,; Lafayette City Center %.,, = :" +; 2 Avenue de Lafayette, Boston,MA 02111-1750 .:". ...: •... H IVW mass.gov/dit[ Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers applicant Information Please Print Legibly game (Business/Organization/individual):THE FIRE PLACE ddress:100 STATE ROAD :ity/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463 re you an employer? Cheek the appropriate box: Type of project(required): Si I am a employer with 10 4. ❑ I am a general contractor and I 6 ❑New construction employees (full and/or part-time).* have hired the sub-contractors ❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. 0 Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' romp.insurance comp. insurance.t 0 We are a corporation 5, and its 10.0 Electrical repairs or additions 0 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions m sell: [No workers' comp. right of exemption per MGL yp 12.0 Roof repairs insurance required.) 1. c. 152,§1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] ty applicant that checks box#l must also fill out the section below showing their workers'compensation policy information. omeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. mtractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have )loyees. If the sub-contractors have employees,they must provide their workers'comp.policy number. ni an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site "Or'1r1 atioll. lurance Company Name:MA RETAIL MERCHANTS WC GROUP INC liey#or Self-ins.Lie. #:01400503301116 Expiration Date:1-1,-23 b Site Address: 7'5 .(�JS1`ta me�ri1 �jj City/State/Zip: . /%ar'11cc :tack a copy of the workers' compensation policy declaration page(showing the policy number and expiration datje). ilure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a ie up to S 1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a tine up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of vestigations of the DIA for insurance coverage verification. to hereby certkto e''r44the pains an 1 nalties of'pezjur j'that the information provided above is true and correct. anaturc: ,, -(1 - ak Date: /0'..2P'� lone#; 413-397-3463 • y Official use only. Do not write in this area,to he completed by city or tmvrz official City or Town: Permit/License# Issuing Authority(check one): 1❑Board of Health 21:Building Department laity/Town Clerk 4.0 Electrical Inspector 50Plumbing Inspector 6.0Other Contact Person: Phone#: Dimensions • A 16 7/8" �I 430mm • I , g 23 3/8" 20„ 595mm 510mm •I i,aum 5„_� I� 125mm 29 1/2" 21 7/8" 750mm 555mm �— 24" 610mm 6 7/8" 175mm 16 7/8" �� 430mm N � t The Insert is equipped with a 10" 6" I.D. removable Flue Collar. 255mm imoin_mmummion. 0.1 ■ 29 1/4" 745mm Figure 2: NEO 1.6 Insert LE- dimensions. Surround Dimensions REGULAR OVERSIZED SURROUND SURROUND A 36" 46" B 26" 30" PACIFIC ENERGY 100005365 12 NEO 1.6 INSEFIT LE 270921-32 Minimum Fireplace Dimensions Hearth Requirements: The fireplace's non-combustible masonry hearth must extend 16" in front and 8" beyond each side of the existing fireplace opening. See Figure 2. r I I I I I I 11 I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I A 301I I I 760mm I I 241/2,, I. 625mm-� I I I 201 /4 " I I 515mm 17„ I _±.7_711! 430mm X I I „ 16" � g- Ai-- Fireplace Hearth 406mm 200mm t Figure 3: Fireplace opening dim. - NEO 1.6 Insert LE. PACIFIC NEO 1.6 INSERT LE 270921-32 13 100005365 ENERGY Ember Protection: Combustible flooring in front of the fireplace insert must be protected from hot embers by non-combustible material extending; • Canada - 18" to the firing side (From the Glass) and 8" to each side of the unit. • U.S.A. - 16" to the firing side(From the Glass) and 8" to each side of the door opening. Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and N.F.P.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA. ill CAN: 20 1 /4" / 610m m ► � 11 • USA: 18 1 /4" � CAN 18 / 406mm ► • 41111 USA: 16" Ember NI III Protection —A _1 IIII 1—dI Masonry Hearth Figure 4: NEO 1.6 Insert LE- Ember protection. Optional Leveling Legs Leveling legs(bolts) are provided if you need them to level or steady the insert on an uneven hearth. • If you fireplace is lower than the hearth mount the rear leveling leg bolts. Prop the unit up to a access threaded inserts under the sides towards the rear of the unit. Thread supplied bolts into insert., set depth to correspond to depth of fireplace drop. • Push the Insert into position in the fireplace and adjust the leveling bolts as needed to level th- Insert. PACIFIC ENERGY 100005365 14 NEO 1.6 INSER LE 270921-32 Clearances The minimum required clearances to surrounding combustible materials when installed into a masonry or factory built fireplace are listed below and in Figure 4. Mantel or Mantel Facing Fri ,___ _ t I I 1 I _-L_ —1— ► ► 13" ► , II 330mm I ■ cm 34 3/8" 13" I 1 . 840mm 330mm ` 61) �gII . 1I /n Adjacent II .. li / / Fireplace Hearth \ 9 1/2" 240mm Figure 5: NEO 1.6 Insert LE Clearances. Minimum Clearances to Combustibles Side of Door to Adjacent Sidewall 13 in.(255 mm.) Side of Door to Side Facing (max 3-1/2 in. deep) 9.5 in.(155 mm.) Top of Front Brow to Mantel Facing 13 in.(305 mm.) Top of Front Brow to Mantel (max 12in. deep) 13 in.(305 mm.) In front of Insert 48 in. (1.22m) CAUTION: Unit hot while in operation. Parts of the appliance, especially the external surfaces, will be hot to touch when in operation. Keep children, clothing and furniture away. Contact may cause skin burns. NEO 1.6 INSERT LE 270921-32 15 100005365 PACIFIC ENERGY Installation Your Insert is designed to be installed into a masonry or factory built zero-clearance wood burning fireplace. The masonry fireplace and chimney must be good working condition and built according to the requirements of the Standard of Chimneys, Fireplaces, Vents and Solid Fuel Burning appliances, N.F.P.A. 211 (Latest Edition) or applicable National, Provincial, State or local codes. The installation shall conform to CAN/CSA- B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. The factory built zero-clearance fireplace and its chimney must be listed per UL 127 or ULC S610 standards. Warning: Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. Fireplace Specifications See page 12 for the fireplace minimum size. Chimney height (from hearth) 15' (minimum). • The fireplace and chimney system must be suitable for wood burning use. Check for creosote build up or other obstructions. Have the chimney swept and inspected. Inspect your fireplace for cracks, loose mortar or other physical defects. If repairs are required, they should be completed before installing your insert. • The Insert must be installed in accordance with local and or national building codes. We recommend that our products be installed and/or serviced by professionals who are certified by a "Qualified agency"; NFI (National Fireplace Institute®) in the United States, CSIA (Chimney Safety Institute of America) in the United States and Canada, WETT (Wood Energy Technology Transfer) in Canada or APC (Association des Professionnels du Chauffage) in Quebec Caution: • The fireplace insert is heavy and should be installed by two people. • Place cardboard or heavy blanket on the hearth to prevent damage while installing. Into a Masonry Fireplace The existing fireplace damper is to be locked open or removed completely. WARNING: Do not remove bricks or mortar from your existing fireplace. • Exception: Masonry or steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner, provided that their removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for combustible materials to less than that required by the National Building Code. A metal tag is provided and is to be fastened to the back wall of the fireplace, If the fireplace has been modified to accommodate the insert. PACIFIC ENERGY 100005365 16 NEO 1.6 INSERT LE 270921-32 Full Flue Liner - (Required in Canada) In Canada, this Fireplace Insert must be installed with a continuous chimney liner extending from the Fireplace Insert's Flue Collar to the top of the chimney. The chimney liner must conform to the class 3 requirements of CAN/ULC-B365, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-5640, Standard for Lining Systems for New Masonry Chimneys. The Insert is equipped with a 6" I.D. Flue Collar. 1. Measure the chimney height from the top of the existing Chimney flue to the floor of the hearth. This will allow extra length of liner for flashing and rain cap. 2. Feed the stainless steel liner from top of the chimney, through the damper area and into the fireplace cavity. Attach a "stove to liner" Rain Cap adapter to the bottom of the liner as per the liner manufacturer's instructions. Stainless Steel ' 'TI. Chimney Flashing3. The Flue Collar is packaged in the stove. Attachthe Flue Collar to the liner adapter and secure with three Stainless screws. Caulk around connections with high temp stove cement. Ensure the gasket is Code Approved in good working shape. Stainless Steel 4. Remove the Front Trim by lifting up on each side, Rigid or Flex Liner r then pull it towards you to release the tabs. logi� 5. Remove the Backing Plate by removing the two screws (T20 Torx) on each side, pull towards you, ;� • — _ and lift up to remove. Full Flue Liner — 6. Remove the Baffle, following the instructions. See owm — Ili "Baffle Removal" on page 11 I,'// — MO 7. Push unit into the fireplace. Use the front or rear adjustment legs, level the insert depending on =" �� your hearth configuration. (NOTE: Adjustment legs are located in the bottom, sides, front and rear of Flex Liner Nil Vat%7Qm the insert). Connector ���� 8. Reach through the flue opening and pull downIM on the Flue Collar with the tool provided until the bolts pass through the mounting holes in the flue -- opening. Install the clamps and nuts. Center the collar on the opening and tighten the nuts. kl IN 9. Measure, trim and shape a Chimney top flashing = to fit the existing chimney flue. Plan for a 1" to Figure 6: NEO 1.6 Insert LE full flue liner. 1-1/2" overlap on each side. Place flashing over top of the liner and seat firmly against the flue tile. 10.Attach a rain cap to the end of the liner. A storm collar may be used if desired. 11. Re-Install the Backing Plate and then the Front Trim - Make sure the Front trim itabs are fully ngaged. PACIFIC NEO 1.6 INSERT LE 270921-32 iimmm 17 10000536 • ENERGY