Ketay Sarah - Ver. 0.05 pt WB SS (1)DRIVEWAYFRANKLIN ST⅊ ⅊ ⅊ ⅊ GO VERNING CODESPARCELMAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE: SHEET SHEET TITLE EMAIL:AdvancedSolarSolutions 2372MorseAve#912 Irvine, CA 92614 PHONE:559-321-7000EMAIL:info@advpermits.com PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLIC ABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) MOUNTING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONS ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHER JURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCAL JURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSO APPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ REQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT ROOF COVERING RELEASEREVDATENAMECOVERSHEETAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH N/A VB 6.480 KW PV-001 COVER SHEET Ketay, Sarah Jake Stocker 2015 National Grid 2015 86111649 2015 21134A (413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City of Northamptonjstocker@valleysolar.solar 50507 Civil (202) 874-3483swyssling@wysslingconsulting.com R-3 II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr(413) 584-8844 Alpine, UT 84004jstocker@valleysolar.solar Ketay, Sarah67 Franklin St, Northampton, MA 01060 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 REC405AA Pure Black Enphase IQ8PLUS-72-2-US IronRidge XR100 Rail IronRidge FlashVue FV-01-M1 INTEGRATED IN INVERTER N/A 16 16 N/A 35 N/A N/A 1 (E) GPS COORDINATES (42.32531,-72.643456) 4.800 KW 2 120/240V - 1 37° 197° 117 Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS Enphase Energy X-IQ-AM1-240-4 200A BUS/200A MAIN BREAKER LINE-SIDE TAP PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSGENERALNOTESGENERALNOTES:* PROPERACC ESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONS AREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT. INTHISPLANSET ARECALCULATEDONCIRCUITS50’INLENGTHORLONGER, THETOTALVOLTAGEDROPFROMINVERTERTOPOINTOF CONNECTIONORUTILITYTRANSFORMERARENOT CALCULATED.ELECTRICALCONTRACTORMUSTEVALUATE ANDFIELDVERIFYINVERTERMANUFACTURESMAXVOLTAGE DROPREQUIREMENTSANDDETERMINETHETOTALVOLTAGE DROPWITHINCIRCUITSASDIRECTEDBYMANUFACTURER ANDCOMPLYWITHSUCHLIMITATIONSANDREQUIREMENTS, (TYPICALLY2%FROMINVERTERTOPOI/POC,AND3%FROM INVERTERTOUTILITYTRANSFORMER.)N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 SECTION 1 RA 2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND *EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PVARRAYLAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH /TILT EXISTING ROOF SECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSTHIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION NORTH PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8” = 1’0” @ SHEET SIZE A3 1361SECTION-1 319 23.44% 197 37°SECTION-1 QTY 16 REC405AA Pure Black MODULES, QTY 16 Enphase IQ8PLUS-72-2-US MICRO INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 26'-8"15'-3"SHEET NOTES *EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKINGLAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFIN G COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/RETRO FIT FLASHING *DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP B. ANCHOR SPACING SHOWN IN DETAIL.UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.SEE "TABLE OF DIMENSIONS"EACH SECTION DETAILED FOR HORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT MANUFACTURERS. FRAMING INFO ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH SCALE: 1/8” = 1’0” @ SHEET SIZE A3 Rafter - Cathedral Ceiling 24" O.C. 2"x6" @ 24" MAX OC Comp Shingle 2.88 PSF QTY 16 REC405AA Pure Black MODULES, QTY 16 Enphase IQ8PLUS-72-2-US MICRO INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 9:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 SHEET NOTES PV RACKING LEGEND 21SCALE:NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. STRAND BOARD OR PLYWOOD.1X SKIP SHEATHING IS ACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS)THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES;IT SHALL BE NO MORETHANTWOLAYERS.(SHOWN) F.IF ROOF COVERING IS TILE;ITS A SINGLE LAYER.ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND,WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE.(SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24"O.C. K. # SCALE:NTS SCALE:NTSSCALE:NTS SECTIONELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT.ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX.STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFIN G COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT.ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX.STANCHION O.C. *DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION# MODULE GROUP PER RAIL MANUFACTURER MAX RAFTER SPANMAXRAFTERSPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS.ACTUAL FIELD CONDITIONS MAY VARY.DETAILSARE SHOWN FOR DIAGRAM USE ONLY.REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBYPVMODULESANDEQUIPMENT. M. ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSRISE HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 3 OH1HS1 PV1 D3 D2 D1 D2H1R2R1*IF BLOCKING REQUIRED32 S-201 1 S-201 **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. 12RISE 5 6 8 1 7 3 PV1 D2D1 D1H1R1D3D2 D224"MINWHENNOTSTAGGERED.TYP *IF BLOCKING REQUIRED32 S-201 1 S-201 D3 HORIZONTAL SPAN OH1HS1R2 **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. BOLTLAG5/16X4.25" 2.5"MINEMBEDMENT GRIPCAP IRONRIDGEFMFLASHING (E)FRAMING @ASSUMED24"O.C.TYPICAL 2'-0" TYP.4'-0"MAX CATHEDRAL CEILING / RAFTER - PORTRAIT CATHEDRAL CEILING / RAFTER - LANDSCAPE EXPLODED STANCHION & FLASHING DETAIL STANCHION SPACING DETAIL XR100 Rail FlashVue FV-01-M1 Integrated 37° 3" - 6" TYP 10" 20" 20.25" 6" 12'-1" 37° 3" - 6" TYP 17.92" 35.85" 36.1" 6" 12'-1" 25' Comp Shingle NOT USED 12'-1"12'-1"S-200PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 SHEET NOTES PV RACKING LEGEND *DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE:NTS 3 4 SCALE:NTS SCALE:NTSSCALE:NTS ATTACHMENTDETAILSROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION# MODULE GROUP ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSMODULE ENDCLAMP FLASHING (E) ROOF SHEATING /DECKING ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS IRONRIDGE FLASHVUE (W/ INTEGRATED FLASHING) PV MODULE, BY OTHERS IRONRIDGE RAIL (E) BUILDING STRUCTURE 1/3"OF TOTAL SPAN MAX 2/3"OF TOTAL SPAN MAX RAIL MANUFACTURER RAIL SPLICE KIT SEE "S-100 /TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE. SEE SHEET "S-100"FOR: HORIZONTAL ANCHOR SPAN SPACING. (E)FRAMING TYPICAL *MODULES SHOWN PORTRAIT IN EXAMPLE DC AND/OR 1/3 CANT. MAX COMPONENT + 2"FROM SIDEOFMODULE 2" ROOF TOP CONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONSTOMEET WEIGHT REQ.OF EQUIPMENT DCB *MODULES SHOWN PORTRAIT IN EXAMPLE **RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERS ARE CUT OR NOTCHED *SEE DETAILS "1-2/S200"TABLE OF DIMENSIONS HOLESALLOWEDONLYIN MIDDLEHALFOFFRAMINGSPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRD OF FRAMING DEPTH,*R2,AND NO LARGER THAN *R2/4 IN DIAMETER.MINIMU M SPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOT TO EXCEED FRAMING LENGTH IN FEET DI VIDED BY 20 NOTCHES DEEPER THAN 1/4" NOT ALLOWED ALONG TOP OR BOTTOM EDGE OF FRAMING NOTE:WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF, VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RID GE LENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT10/7/2022 PV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR.PMAX TEMP COEFFICIENT [-0.#%/C]*100 FORMULA CORRECTEDTEMP. COEFFICIENT MODULE Voc [VDC] TEMPERATURECORRECTED OPEN CIRCUITVOLTAGE - =*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L"x W"x D"/THICK PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (SHORT-CIRCUIT POWER)AMPS MFR.Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP.CORRECTED Voc VOLTS DC AC C OMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POL ES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC S UB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE /MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C.BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) AC S UB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE /MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C.BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFIC ATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max PV POWER @ MODULE STC WATTS Max INPUT DC VOLTAGE VOLTS DC Max INPUT CURRENT AMPS MODULES PER MICRO INVERTER QTY AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX.OUTPUT CURRENT AMPS -MAX AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POL ES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 ALT.ENERGY BACKFEED BREAKER (IF APPL.)AMPS (Imax)RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CALCULATIONSE-001REC REC405AA Pure Black4571.7 x 40 x 1.2 405 48.9 42.4 10.39.56-0.24 20.0 Enphase IQ8PLUS-72-2-US 290 2.38 290 6015.0 1 240201.21 Enphase EnergyX-IQ-AM1-240-4 240125 23R N/A 19.362 Eaton DG222URB NON-FUSIBLE DISCONNECT 120/2406023R N/A 19.36 EXISTING120/240V Single Phase 200200 040 -20 25 -45 -0.24%0.11 1 1.11 48.9 54.28 54.28 1 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT ≤ ≤ DC WIRE AND CONDUIT SIZ ING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPAC ITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITY PER 310.16 MAXCURRENT 690.8 (A)(1) CONT.OPERATION 690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVE ROOF (in) TEMP.ADDER PER 310.15 (B)(2)(c) OPERAT.TEMP. AMPACITY CORRECTION310.15 (B)(2)(a) #OFUNGRND. COND. AMPACITY CORRECTION310.15 (B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILL DERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY DC1 XXX=XX= 1.ANY CONDUCTOR LENGTH UNDER 50'DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS;WORST CASE SCENARIOS,ROUNDING UP SIZES OF CONDUCTORS THAT AREEQUIPMENT GROUND GREEN OR BARE,OR GREEN/YELLOW (NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONDUCTOR(S)HOT:CONVENTION IS L1 BLACK CONVENTION IS L2 RED WIRE AND CONDUCTO R NOTES WHEN LESS THAN 10'-0"OR 10%OF THE CIRCUIT LENGTH;THE LESSER AMPACITY MAY BE USED.USED BEYOND THE POINT OF TRANSITION,A DISTANCE EQUAL TO 10'-0"(3 METERS)OR 10%OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY,WHICHEVER IS LESS. 4.CEC/NEC 310.15(A)(2)(AS APPLICABLE)WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT,THE HIGHER AMPACITY SHALL BE PERMITTED TO BE AC WIRE AND CONDUIT FILL DERATE CHART [SEE SHEET E-003 FOR THR EE LINE DIAGRAM] TAG CIR CUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION 690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENT TEMP. HGT.ABOVE ROOF (in) TEMP.ADDER PER310.15 (B)(2)(c) OPERAT. AMPACITYCORRECTION310.15 (B)(2)(a) #OFUNGRND.COND. AMPACITYCORRECTION310.15 (B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY AC1 X =X X = AC2 X =X X = AC3 X =X X = AC4 X =X X = AC5 X =X X = AC6 X =X X = AC7 X =X X = AC8 X =X X = AC9 X =X X = AC10 X =X X = #OFCOMBINEDPARALLELCIRCUITS QTY INPARALLEL & MATERIAL QTY INPARALLEL & MATERIAL DESTINATION MAX INV.OUTPUT CURRENT (AMPS) ORCOMPONENT(AMPS) lsc (AMPS) ORCOMPONENT(AMPS) ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ EQUIPMENT GROUNDGREEN OR BARE,OR GREEN/YELLOW TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY CONVENTION IS RED FOR GROUNDED SYSTEMS RED (+)AND BLACK (-)FOR UNGROUNDED SYSTEMSRELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSWIREANDCOND.CALCS.PV MODULE INVERTER (1) CU 90 #12 AWG 30 10.3 1 1.25 1.25 16.1 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 16.1 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 9.68 12.1 ROOFTOP 35 >7/8"0 35 0.94 2 N/A 25 0.94 1.0 23.5 12.1 23.5 AC COMBINER (1) CU 75 #10 AWG 35 1.25 9.68 12.1 ROOFTOP 35 >7/8"0 35 4 .80 350.94 0.94 .80 26.3 12.1 26.3 AC DISCONNECT (1) CU 75 #10 AWG 35 1.25 19.36 24.2 EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 24.2 32.9 CIRCUIT BREAKER DISCONNECT (1) CU 75 #10 AWG 35 1.25 19.36 24.2 EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 24.2 32.9 EXISTING SERVICE PANEL (1) CU #6 AWG 65 1.25 19.36 24.2 EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER AC DISCONNECT CIRCUIT BREAKER DISCONNECT 75 35 0.94 3 1.0 65 0.94 1.0 61.1 24.2 61.1 E-002WIRE COLOR CODING (2020) NEC SECTIONS 250.119 & 200.6 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT LEGEND THREELINEDIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 MICRO INVERTER 3 AC COMBINER BOX 4 JUNCTION BOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT (FUSIBLE) 7 PROD/GEN METER 8 SUB PANEL 10 11 12 EXISTING UTILITY METER TAG BRANCH MODULE QTY OCPD BACK-FEED SOLAR BREAKER: TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE AC6 AC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS • 13 BATTERY 14 NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND ELECTRICAL NOTES SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS CONDUCTOR TABLE CONDUIT TABLE •INTEGRATED MICRO INVERTERS (AC MODULES) MUST BE CERTIFIED UL1742 AND UL1703 COMPLIANT. AS EITHER INDIVIDUAL COMPONENTS OR AC MODULE ASSEMBLY. THEY MUST ALSO BE LABELED "UTILITY INTERACTIVE" CONFORMING TO IEEE1547 TESTING. •PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN AC MODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINAL LISTING OF THE PV MODULE AND VOID THE WARRANTY OF THE MODULE. •VERIFY MODULE IS COMPATIBLE WITH MICRO INVERTER MANUFACTURER AND MODEL. •ARTICLE CEC/NEC 690 STILL APPLIES. THE INSTALLER WILL NEED TO CONSIDER REQUIREMENTS SUCH AS: DC GROUND FAULT DETECTION AND INTERRUPT, DC CABLE MANAGEMENT, DC DISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE AC EQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOT BE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITY INTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATED FOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSG G L1 L1 L2 L2 4 L1 L1 L2 L2 AC1 AC2 L2 L1 G BUS RATING 3 L2L1 G N ENVOY-IQ FOR MONITORING NEGC EGC 125A 20A 20A 15A (+) (+) 2 2 AC DC(-) (-)DC AC 1 1 DC 1 INVERTER NAMEPLATE MODULE NAMEPLATE (-)(+) (-)(+) AC DC AC DC 2 2 1 1 8 MODULES RATING 405W 8 MODULES RATING 300W/240V NOTE: CONDUCTORS AC3,AC4 & AC5 MAY BE THWN-2 OR SER CABLE. EGC M 12 G N BUS RATING 11 MAIN C/B RATING GEC 200A 200A L2 L1 L2 L1 GG NN 6 AC4 COMPLIES WITH NEC 240.21 OCPD RATING 30A L2 L1 G N L2 L1 G N 14 READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEAR METER NEMA 3R RATED AC5AC3 2 STRINGS (L1/L2 SHOWN) OF 8 MODULES 16 REC405AA Pure Black Enphase IQ8PLUS-72-2-US JayBox QM-JBX-RL01-B1 Eaton DG222URB 1 8 20A 2 8 20A 120/240V - 1 #12 AWG PV Wire Open Air N/A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER NEC 705.12(A) 16 1 1 0 1 0 0 0 1 1 2 #6 AWG N/A 3 #12 AWG TRUNK CBL #6 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #6 AWG THWN-2 #8 AWG 3/4 inch EMT Enphase Energy X-IQ-AM1-240-4 E-003EXISTING MAIN SERVICE PANEL 200A BUS/200A MB 0 CIRCUIT BREAKER DISCONNECT 70A BUS MLO1 NOTE: ALL LINE SIDE PV CIRCUIT CONNECTIONS INVOLVING TAPS AND OR TRANSFORMERS SHALL INCORPORATE GROUNDING ELECTRODE CONDUCTORS (G-N BONDING) IN ALL LOCATIONS THAT ARE SEPARATELY DERIVED SYSTEMS AS REQUIRED BY CODE AND OR THE AHJ. GROUND BONDING JUMPERS (CONDUCTORS), TO CONNECT ANY APPLICABLE SEPARATELY DERIVED SYSTEMS SHALL BE FIELD VERIFIED BY QUALIFIED ELECTRICAL CONTRACTOR Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT ACCACSP M JB ELECTRICALLAYOUTEQUIPMENT GROUNDING 1.METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1.WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSORLUGS,WITH APPROVAL OF AHJ AND RACKING MFG.WEEBS ARE ONE TIME USE ONLY.SEE "we-llc.com"FOR RACKING SPECIFIC WEEB,INSTALL INSTRUCTIONS,AND UL 2703 CERT. 1.2.FOR "LAY-IN"LUG MODULE GROUNDING;CORRECT HARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSIONMUSTBEUSED.TYPICALLY DIRECT BURIAL RATED,TINNED,OR STAINLESS STEEL.GROUNDING LUGS MUST BEATTACHEDATMARKEDLOCATIONONEACHMODULE. 2.THE EGC (EQUIPMENT GROUNDING CONDUCTOR)IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETALPARTSTHATMIGHTCOMEINTOCONTACTWITH CURRENT-CARRYING CONDUCTORS,INCLUDING THE FOLLOWING: 2.1.PV MODULES FRAMES,ARRAY MOUNTING RACKING;THEMETALCHASSISOFEQUIPMENTSUCHASINVERTERS, DISCONNECTS,METERS,JUNCTION BOXES AND COMBINERBOXES;AND METAL CONDUIT HOLDING CIRCUITS >250 VOLTSTOGROUNDPERNEC250.97 3.THE GEC (GROUNDING ELECTRODE CONDUCTOR)IS THECONDUCTORUSEDTOCONNECTTHEGEORGESYSTEM TO THE SYSTEM GC,TO THE EGC,OR TO BOTH. 4.THE GE (GROUNDING ELECTRODE)IS A CONDUCTING OBJECT,OFTEN A ROD,RING,OR PLATE ESTABLISHING A DIRECTCONNECTIONTOEARTH.THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATEDINSUB-PANELS OR ANYWHERE ELSE ON AC SIDE.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSELECTRICAL SYMBOL LEGEND AC DISCONNECT PERFORMANCE METER UTILITY METER JUNCTION BOX AC P M SERVICE PANELSP AUTO TRANSFORMERATF SOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT CLP CRITICAL LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUB ATS AUTO TRANSFER SWITCH CB CIRCUIT BREAKER DISCONNECT SECTION 1 PV ARRAY TAGSECTION#MODULE GROUP EMERGENCYBATTERYDISCONNECTEB RS EMERGENCYRSDSWITCH TESLAGATEWAYTGW TESLAPOWERWALLTPW STS SMART TRANSFERSWITCH ￿￿￿ CB NORTH SCALE: 1/8” = 1’0” @ SHEET SIZE A3QTY 16 REC405AA Pure Black MODULES, QTY 16 Enphase IQ8PLUS-72-2-US MICRO INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER.E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT SHEET NOTES1SCALE: 1/2"=1'-0"CONDUIT,RACEWAY,J-BOX,AND PULL BOXES 2 3 5 6 7 SCALE: 1/4"=1'-0"8 9 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10'(60"),12" FROM BENDS,12"ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE:NEC 690.31(G)(3) 3.MINIMUM OF 1 1/8"x 5 3/4" 4.FONT:3/8"AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX,DC COMBINER,AND DC DISCONNECT SCALE: 1/4"=1'-0" NON-LOAD BREAK DC COMBINER /J-BOX 1.PLACED ON DC DISCONNECT(S)AND ON ANY EQUIPMENT THAT STAYS EN ERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE:NEC 690.13(B) 3.MINIMU M OF 3 1/2"x 10" 4.FONT:3/8" INVERTER(S) SCALE: 1/2"=1'-0" 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDONORNOMORETHAN1M(3 FT)FROM THE SWITCH THATINCLUDESTHEFOLLOWING: 1. 2. MINIMUM OF 3 1/2"x 10 1/2" FONT:3/8" AC AND DC DISCONNECTS 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE:NEC 690.13(B) 3.MINIMUM OF 1"x 10 1/2" 4.FONT:3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" 1.CODE REFERENCE:NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1"x 6" 4.FONT:3/8"AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1. 2. VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3. MINIMUM OF 1"x 4" FONT:3/8"AND .8 WIDTH FACTOR SWITCHBOARDS SCALE: 1/2"=1'-0" INVERTER # 1 1.USE PLACARD "INVERTER #1"WHEN MORE THAN 1INVERTER IS USED.NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1"x 4" 3.FONT:3/8" 4.WHITE LETTERS ON A RED BACKGROUND. USE PLACARD "[AC][DC]DISCONNECT #1"WHEN MORE THAN ONE DISCONNECT IS USED.NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. SCALE: 1/4"=1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE.ALL INFORMATION FROM THE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT,ENCLOSURES,RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES,COMBINERBOXES AND DISCONNECTS ARE MARKED.(NEC 690.31[G],NEC690.13 &690.53) 4.THE MARKINGS ON THE CONDUITS,RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET,WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS ANDBARRIERS.(IFC 605.11.1.4,NEC 690.31[G][3]) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP,LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AN D ASSOCIATED EQUIPMENT,THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT.MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT.UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING.UL LISTING OF MARKINGS ISNOTREQUIRED.SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT,NON-BOLD. 7.2.MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16"LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERIN G. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE REDUCED AND /OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDANDHAVINGAMINIMUMHEIGHTOF9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4"=1'-0" SCALE: 2CODE REFERENCE:NEC 690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOC ATE NO MORE THAN 1 mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THE OPEN POSITION ! THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT WARNING ARC FLASH HAZARD APPROPRIATE PPE REQUIREDFAILURE TO COMPLY CAN RESULT IN DEATH OR INJURY REFER TO NFPA 70E ! WARNINGWARNING 2017NEC11132021KN 5.WARNING LABEL IS WHITE AND ORANGE 3.WARNING LABEL IS WHITE AND ORANGE 4.WARNING LABEL IS WHITE AND ORANGE 5.DATA COLLECTED FROM AS-BUILT INFO,PRIOR TO PTO,BY OTHERS.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSSTANDARDPLACARDS1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED DURING SERVICE. 3.MINIMUM OF 3"x 10 1/2" 4.FONT:3/8" ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THEOPEN POSITION !WARNING DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES AREEXPOSED TO SUNLIGHT 5.WARNING LABEL IS WHITE AND ORANGE 10 11SCALE: 1/2"=1'-0"INVERTER(S) 1. 2. USE PLACARD "COMBINER #1"WHEN MORE THAN 1DC COMBINER IS USED.NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1"x 4" 4. FONT:3/8"AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. DC COMBINER BOX SCALE: 1/2"=1'-0" ENGINEERING STAMP (if appl.)P-001QTY 16 REC405AA Pure Black MODULES, QTY 16 Enphase IQ8PLUS-72-2-US MICRO INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT UTILITYMETER SOLAR ARRAY ON ROOF TOP N MAIN SERVICEPANEL AC DISCO AC COMBINER SHEET NOTES 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDSFORTHESAMEDEVICE.ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2. 3. 4. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT,ENCLOSURES,RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES,COMBINERBOXES AND DISCONNECTS ARE MARKED.(NEC 690.31[G],NEC 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT.MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT.UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING.UL LISTING OF MARKINGS IS NOT REQUIRED.SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT,NON-BOLD. 5.2.MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16"LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE REDUCED AND /OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT 6.ANSI Z535.4 PRODUCT SAFETY SIGN S AND LABELS:THIS INFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDSMAYBEUSEDWITHPRIORAPPROVALOFTHEAHJ.MOSTNOTABLEDIFFERENCESISCOLOROFPLACARDSANDUSEOFHANDWRITTENVALUESWITHINDUSTRIALMARKERSONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE.I.E.ADDING MODULES AT A FUTURE DATE,OR STANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT.AHJ APPROVAL REQUIRED.(SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 2 3 4 SCALE: 1/4"=1'-0" MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/4"=1'-0"UTILITY METER,SERVICE PANEL,SUB-PANELACDISCONNECT,AC SUB-PANEL 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 /AC DISCONNECT [#]" 3.CODE REFERENCE:NEC 690.54 4.MINIMUM OF 1 1/2"x 8 1/2"(TOP),1 3/4"x 6 1/2"(BOT) 5.FONT:3/8"HEADER,3/16"DATA 6.WHITE LETTERS ON A RED BACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1)PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEM SUPPLY BREAKER AT POINT OF INTERCONNECTION.(#2 &#3)PLACARD(S) REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT ARE NOT LOCATED NEXT TO EACH OTHER.MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS.IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS;SEE SHEET "E-001 /STRING INVERTER[#]SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT"WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE"WILL BE THE NAME PLATE RATING OF THE INVERTER 3.CODE REFERENCE:NEC 690.54,NEC 705.12(B)(3) 4.MINIMUM OF 2"x 6 1/2"(#1),VARIES (#2 &#3) 5.FONT:3/8"HEADER,3/16"DATA (#1),1/4"(#2 &#3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2"=1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCON NECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE DISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 7 3/4"x 5" 6.FONT:3/4""CAUTION",1/4""WARNING",3/16"HEADER, 1/8"DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECTINALOCATIONCLEARLYVISIBLEFROMWHERETHE DISCONNECT IS OPERATED.(CFC 605.11.1.3 &CRC R331.2.3) MAP PLACARD:MAIN SER VICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE: 1/2"=1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PV INVERTER AND PV DISCONNECTS IF NOT ATTHESAMELOCATION. 2.MAP PL ACARD PROVIDES A DIRECTORY OF THESERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2"x 6 1/2" 6.FONT:3/4""CAUTION",1/4"HEADER,1/8"DATAANDNOTES 7.PLACARD WILL BE PLACED ADJACENT TO THEMAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT ISOPERATED.(CFC 605.11.1.3 &CRC R331.2.3) AC C OMB INER DYNAMICPLACARDSAC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE: 1/2"=1'-0" 1. 2. USE PLACARD "COMBINER #1"WHEN MORE THAN 1 AC COMBINER IS USED.NUMBERACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1"x 4" 4. FONT:3/8"AND .75 TO .8 WIDTH FACTOR MINIMUM. 5. WHITE LETTERS ON A RED BACKGROUND. PLACARDS MAY BE COMBINED TOGETHER.I.E."AC COMBI NER BOX #1".MINIMUM REQUIREMENTS LISTED ABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 #1 #2 #3 CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) 1.PRIME CONTRACTOR /PERMIT APPLICANT SIGNER IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEM INSTALLATION.PRIME CONTRACTOR /PERMITAPPLICANT SIGNER WILL BE RESPON SIBLE FOR COLLECTION OF EXISTING ONSITE INFORMATION REQUIREMENTS TO DESIGN,SPECIFY,AND INSTALL THE EXTERIOR MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEM DETAILED IN THIS DOCUMENT. 2.ADVANCED SOLAR SOLUTIONS,INC ISRESPONSIBLEFORAPPLYINGSUPPLIEDINFORMATION INTO ASETOFPERMITDRAWINGS.ANY CHANGES TODRAWINGSARESUBJECTTOCONTRACTCONDITIONSBETWEENTHECLIENTANDADVANCEDSOLARSOLUTIONS,INC.INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSCIRCUITBREAKERDISCONNECT UTILITYMETER SOLAR ARRAY ON ROOF TOP MAINSERVICEPANEL AC DISCO AC COMBINER CIRCUITBREAKERDISCONNECT N 19.36 240 19.36 240 19.36 240 19.36 240 19.36 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT rec Alphα® pure Black Series Product Specifications αexperience performance 400 wp 20.3 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Ref: PM-DS121Rev- A .21Founded in 199, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is commied to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. GR GR GR GRGR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1]975±2.5 [38.4±0.1]1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5 [0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] Measurements in mm [in]Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of P MAX:.2 /°C Temperature coefficient of V OC:.24 /°C Temperature coefficient of I SC:.4 /°C *The temperature coefficients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 255 kW Product Warranty (yrs)225 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)25 1 Power in Year 1 989898 Annual Degradation .25.25.25 Power in Year 25 929292 See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxAA Pure Black Power Output - PMAX (Wp) 85 995 445 Wa Class Sorting - (W)/+5 /+5 /+5 /+5 /+5 Nominal Power Voltage - VMPP (V) 41.2 41.5 41.8 42.1 42.4 Nominal Power Current - I MPP (A) 9.5 9.49.45 9.51 9.5 Open Circuit Voltage - VOC (V) 48.5 48.48.7 48.8 48.9 Short Circuit Current - ISC (A) 9.99 1.1.7 1.11.14 Power Density (W/sq )19.19.19.8 2.1 2. Panel Efficiency () 2.8 21.1 21.21.21.9 Power Output - PMAX (Wp)29297 1 5 9 Nominal Power Voltage - VMPP (V) 8.8 9.1 9.4 9.7 4. Nominal Power Current - I MPP (A) 7.55 7.59 7.7.8 7.72 Open Circuit Voltage - VOC (V) 45.7 45.8 45.9 4.4.1 Short Circuit Current - ISC (A) 8.7 8.18.18.18.19 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1.75 W/sq (1 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±% within one wa class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 8 W/m², temperature 8°F (2°C), windspeed . /s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 12 half-cut REC heterojunction cells with lead-free, gapless technology strings of 22 cells in series Glass:.1 in (.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:-part, bypass diodes, IP7 rated in accordance with IEC 279 Connectors: Stäubli MC4 PVKBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 2852 IP8 only when connected Cable:12 AWG (4 mm² PV wire, 4+ 47 in (1.1 + 1.2 m) accordance with EN 518 Dimensions:71.7 x 4 x 1.2 in ( x 06 x 30 mm) Weight:45 lbs (2.5 kg) Origin:Made in Singapore STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:4 ... +185°F 4 ... +85°C Maximum system voltage:1 V Maximum test load (front): + 7 Pa (14 lbs/sq )* Maximum test load (rear):- 4 Pa (8.5 lbs/sq )* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC 1215:21, IEC 17:21, UL 17 Pending ISO 141:24, ISO 91:215, OHSAS 181:27, IEC 2941 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSPV MODULE CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry’s rst microgrid-forming, software- dened microinverters with split-phase power conversion capability to convert DC power to AC power eciently. The brain of the semiconductor-based microinverter is our proprietary application-specic integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or o-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redene reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Congurable to support a wide range of grid proles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SE-DS-0001-01-EN-US-2021-10-19 DATA SHEET (1) The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to dene the number of microinverters per branch in your area. IQ8 Series Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US1 Commonly used module pairings2 W 235 – 350 235 – 440 260 – 460 295 – 500 320 – 540+295 – 500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 33 – 45 36 – 45 38 – 45 38 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current3 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array conguration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range4 V 240 / 211 – 264 208 / 183 – 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit5 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak eciency %97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted eciency %97 97 97 97.5 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SE-DS-0001-01-EN-US-2021-10-19 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT KN 88R,SR TheXRRailFamilyoffersthestrengthofacurvedrailinthreetargetedsizes.Eachsizesupportsspecic HVORDVZOHDHDOFRVVHSHRRXORFDRHHVD55DORDF nXT8MTIRRXMNXXXTXMISXIRRLXSXTLXSTXT IN(XL 8R9RIT 7HIROORZDEOHZDVSHSDHFRSODFHZDSSOFDEOHHHHFRHVDVDDV9DOXHVDH EDVHRHIROORZFHD65RRIRHSRVXH5RRI6ORSHRIRHHHVD0HD BuildingHeightof30ft.VisitIronRidge.comfordetailedspantablesandcertications. 8 5VHXODHHVHDO RXDO,VXSSRVDDHRI ZDVRZFRRVZOHDOVR DVSDVXSRIHH VSDFDSDEO HDORDFDSDEO Clear&blackanodizednish ,HDOVSOFHVDDODEOH 8 XR10isasleek,low-prolemounting DOHVHIRHRVZOR RVRZ,DFHHVIRRVSDVZOH HDODHFRRFDO VSDFDSDEO 0RHDHORDFDSDEO Clear&blackanodizednish ,HDOVSOFHVDDODEOH 8 5VDHDZHDR VRODRXDOV,VEXORDOH HHHFODHVDVSDVIHHR RHIRFRHFDODSSOFDRV VSDFDSDEO HHORDFDSDEO Clearanodizednish ,HDOVSOFHVDDODEOH IN(XL 9RX4R9TT 2HHOIHHVRODSDHOVHSHHFHFRXOHVV HHHZHDHHHV1RMXVHZRVVRVHDV EXHZRVVRVHDVZVFDSDEOHRI SSSDHOVIRDRRIDVRZIDOOVZH HRXREXFNOHDSDHOIDH 55DOVDHHVXFXDOEDFNERHSHH HVHHVXOV7HHVVXSOISRHF againstbucklingandsafelyandefciently DVIHORDVRHEXOVXFXH 7HVXSHRVSDFDSDEO HTXHVIHZHRRIDDFHV HXFHXEHRIRRI SHHDRVDHDRX RIVDOODRH 55DODO ,XI9HRTM)X 6ORSHRRIVHHDHERHFDODODHDO IRFHVRRXDOVZFFDFDXVHH REHDZV7HFXHVDSHRI55DOV VVSHFDOOHVHRFHDVHVHER HFRVZOHHVVHZV7VXTXHIHDXHHVXHVHDHVHFXXHHH ZHDHDDORHVVHOIHH )SVHRN,R6IN8L 5RRI0RXXOHV5 5DOVDORZRSRDO DOORHDDFHV tosecuresystemsush DDVHVHDORRIV )XXT8T3XR 55DOVDH FRSDEOHZ ODVRRD RHSFHRRI DDFHV ,R5HRIIHV DDHRIOOH optionsforat RRIRX DSSOFDRV OO55DOVDHDHRIVHHV DOXXDOORHSRHFHZD anodizednish.Anodizingpreventssurface DVXFXDOFRRVRZOHDOVRSR DRHDDFHDSSHDDFH 888 1RH T36.9T69, 8R9VT2RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT I nT8MTIRRMTMISIGRRSTSGTT 38I TGRRGT3GTGR VisitourwebsiteformanualsthatincludeUL 2703ListingandFireRatingClassication. -T8MIS EngineeringCerticationLetters Weoffercompleteengineeringresources andpre-stampedcerticationletters. -T8MIS ,WTRQ7T GGSRV ThenewUL1703standardintroducestheconceptofa PVmoduletype,basedon4constructionparameters and2reperformanceparameters.Thepurposeof thisclassicationistocertifymountingsystemswithout needingtotestitwitheverymodule. Whatroongmaterialsarecovered? Allreratedroongmaterialsarecoveredwithinthis certicationincludingcompositionshingle,clayand cementtile,metal,andmembraneroofs. GGGRGPIT TWRG Generally,olderroofswilltypicallybe“grandfathered in”,andwillnotrequirere-roong.However,if50%or moreoftheroongmaterialisreplacedforthesolar installationthecoderequirementwillbeenforced. Whereisthenewreratingrequirementcodelisted? 2012IBC:1509.7.2Fireclassication.Rooftop mountedphotovoltaicsystemsshallhavethesamere classicationastheroofassemblyrequiredbySection 1505. GRG,8GTMW ThegeneralrequirementforroongsystemsintheIBC referstoaClassCrerating.ClassAorBisrequiredfor areassuchasWildlandUrbanInterfaceareas(WUI)and forveryhighreseverityareas.Manyoftheseareasare foundthroughoutthewesternUnitedStates.California hasthemostClassAandBroofreratingrequirements, duetowildreconcerns. GTGSIRGSVI Midclampsandendclampsareconsideredpartofthe PV“system”,andarecoveredinthecertication. Whatattachmentsandashingsaredeemed ISVGRRG Attachmentsandtheirrespectiveashingsarenot constituentsoftheratingatthistime.Allcode-compliant ashingmethodsareacceptablefromarerating standpoint. GSTTMMGIIVGR ULretestingwasperformedwithagapof5”,whichis consideredworstcaseinthestandard.Therefore,the ratingisapplicabletoanymoduletoroofgap. AmIrequiredtoinstallskirtingtomeetthere I No,IronRidgeachievedaClassAreratingwithoutany additionalrackingcomponents. WhatdeterminesFireClassication? FireClassicationreferstoare-resistancerating systemforroofcoveringmaterialsbasedontheirability towithstandreexposure. ClassA-effectiveagainstseverereexposure ClassB-effectiveagainstmoderatereexposure ClassC-effectiveagainstlightreexposure GITMTRGG TheIronRidgeClassAratingwillnotdiminishthere ratingoftheroof,whetherClassA,B,orC. Whattiltsisthetiltmountsystemreratedfor? Thetiltmountsystemisratedfor1degreesandupand anyrooftomodulegap,ormountingheight. I GIQMT Allroongproductsaretestedand classiedfortheirabilitytoresistre. Recently,thesereresistancestandards wereexpandedtoincludesolarequipment aspartoftheroofsystem.Specically,this requiresthemodules,mountinghardware androofcoveringtobetestedtogetheras asystemtoensuretheyachievethesame reratingastheoriginalroofcovering. Thesenewrequirementsarebeingadopted throughoutthecountryin2016. IronRidgeCertication IronRidgewastherstcompanyto receiveaClassAFireRating—thehighest possiblerating—fromIntertekGroupplc.,a NationallyRecognizedTestingLaboratory. IronRidgeFlushMountandTiltMount Systemsweretestedonslopedandat roofsinaccordancewiththenewUL1703 &UL2703teststandards.Thetesting evaluatedthesystem’sabilitytoresist amespread,burningmaterialand structuraldamagetotheroof. Refertothetablebelowtodeterminethe requirementsforachievingaClassAFire Ratingonyournextproject. 9V 9RG3R SolarmodulesaregivenaType classicationbasedontheir materialsandconstruction. 3TTM9S Mountingistestedaspartofa systemthatincludestype-tested modulesandre-ratedroofcovering. 8TM Roofcoveringproductsaregivena FireClassRatingofA,BorCbasedontheirtestedreresistance. Aburningwoodenblockisplacedonmoduleasafanblowsat12mph. Flamecannotbeseenonundersideofroofwithin90minutes. TTMGT Flameatsouthernedgeofroofisaimeduptheroofasafanblowsat12 mph.Theamecannotspread6feetormorein10minutes. 9VG,RGS ,TM6I 9S 89RV3R,8GTM FlushMount AnySlope Type1,2,&3 TiltMount ≤6Degrees Type1,2,&3 *ClassAratedPVsystemscanbeinstalledonClassA,B,andCroofs. KN RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT KN SimpliedGroundingforEveryApplication 72IDPLORIFRPSRVOLPLDVGIRU VSDUDURXGLDUGDUEERGLVRODUPRGXOV GLUFOR,UR5LG55DLOVOOVVPSVDIDXU 2IDPLOOXV0RX7LO0RXDGURXG 0RXDUIXOOOLVGR/VDGDUG 2DUGDUIRUPVVFXUOFULFDOERGVLER PRGXODGUDLOUVXOLLPDSDUDOOOURXGL SDVURXRXVVP7LVODGVRVDIUDGPRU UOLDEOLVDOODLRV 2DPLORIRPSRV UniversalFasteningObject(UFO) 72VFXUOERGVVRODUPRGXOVR5 5DLOV,FRPVDVVPEOGDGOXEULFDGDG cantawiderangeofmoduleheights. StopperSleeve 76RSSU6OVDSV RR2FRULLLR DERGGGFODPS BondedSplice DFRGG6SOLFXVV VOIGULOOLVFUVRIRUP DVFXUFRFLR1R ERGLVUDSGG BondedAttachments 7ERGLERODDFV DGERGV/IRRR UDLO,LVLVDOOGL VDPVRFNDVUVRI VVP GroundingLug VLOURXGL/X FRFVDLUUR RI3PRGXOVRURXGLFRGXFRU SystemDiagram ULCertication 7,UR5LGOXV0RX 7LO0RXDGURXG0RX 6VPVDEOLVGR/ E,UNURXSSOF /LVVDGDUGIRU DOXDLVRODUPRXL VVPV,VXUVVGLFV LOOPDLDLVUROFULFDODG PFDLFDOFRFLRVRU DGGSULRGRILPL UPRXGRRULURPV ©2016IronRidge,Inc.Allrightsreserved.Visitwww.ironridge.comorcall1-800-227-9523formoreinformation.Version1.10 Cross-SystemCompatibility Feature FlushMount TiltMount GroundMount LO52O RSSU  RGGSOLF1 URXGL/XSU5RSU5RSUUUD LFURLUU RUSLPLU SDV000 DUIR0,0, 6RODUG3333333 LULODVVODVV1 RGXO7VGRUDOXDGLRUUDPG0RGXOV 5IURLVDOODLRPDXDOVIRUDGDLOGOLV í SSURGSDVPLFURLUUVFDSURLGTXLSPURXGLRI,UR5LGVVPVOLPLDLGIRU groundinglugsandeldinstalledequipmentgroundconductors(EGC).Aminimumoftwomicroinvertersmountedtothe VDPUDLODGFRFGRVDPDFDEOLVUTXLUG5IURLVDOODLRPDXDOVIRUDGGLLRDOGDLOV GotoIronRidge.com/UFO RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSSTANCHION - ROOF ATTACHMENT CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSSTANCHION - ROOF ATTACHMENT CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT -1 LIEI-QMIML)RTLEI -EIEERMRIEI0)1GI QSIQMRGISRML-SQMRI GSRSMEIMRIGSRRIGMSRIMTQIR MRSEMRIIRGSIERIEQMRI- QMGSMRIIERSEIMREEMSR TSMMREGSRMIRTIMISMSRS IMIRMEETTMGEMSR-SITSS TSIMRTGMGMER)ESRIMI EEIQ EI -QMI -1 -1 8SPIEVRQSVIEFSX)RTLEWISIVMRKWMWMXIRTLEIS (EELII EI2IXM QEVX -RGPHIW-5+EXIESVGSQQRMGEXMSRERHGSRXVSP -RGPHIW)RTLEWI1SFMPI'SRRIGXGIPPPEVQSHIQ ')001()114MRGPHIHSRPMXL-5 'SQFMRIV' -RGPHIWWSPEVWLMIPHXSQEXGL)RTLEWI-5&EXXIV aestheticsanddeectheat PIMFPIRIXSVOMRKWTTSVXWMM )XLIVRIXSVGIPPPEV TXMSREP%'VIGITXEGPIEEMPEFPISV40'FVMHKI 4VSMHIWTVSHGXMSRQIXIVMRKERHGSRWQTXMSR QSRMXSVMRK MQTPI 'IRXIVIHQSRXMRKFVEGOIXWWTTSVXWMRKPI WXHQSRXMRK TTSVXWFSXXSQFEGOERHWMHIGSRHMXIRXV 9TXSSVTSPIFVERGLGMVGMXWSV:%' TPKMRFVIEOIVWRSXMRGPHIH %XSXEP4:SVWXSVEKIFVERGLGMVGMXW 6IPMEFPI •DurableNRTL-certiedNEMAtype3Renclosure MIIEVPMQMXIHEVVERX 8SIEVWPEFSVVIMQFVWIQIRXTVSKVEQGSIVEKI MRGPHIHSVFSXLXLI-5'SQFMRIV/9W 90PMWXIH -1 8SPIEVRQSVIEFSX)RTLEWISIVMRKWMWMXIRTLEIS k)RTLEI)RIMLIII)RTLEILI)RTLEISS-SQMRIERSLIREQIEIEIQES )RTLEI)RI-RG(EEIGSGLERI -5'SQFMRIV-5%1-5'SQFMRIVMXL)RTLEWI-5+EXIETVMRXIHGMVGMXFSEVHSVMRXIKVEXIHVIIRIKVEHI4:TVSHGXMSRQIXIVMRK%2- 'ERHGSRWQTXMSRQSRMXSVMRK-RGPHIWEWMPIVWSPEVWLMIPHXSQEXGLXLI-5&EXXIVWWXIQERH IQSystemController2andtodeectheat. -5'SQFMRIV'-5%1'-5'SQFMRIV'MXL)RTLEWI-5+EXIETVMRXIHGMVGMXFSEVHSVMRXIKVEXIHVIIRIKVEHI4:TVSHGXMSRQIXIVMRK %2-'ERHGSRWQTXMSRQSRMXSVMRK-RGPHIW)RTLEWI1SFMPI'SRRIGXGIPPPEVQSHIQ ')001()114ETPKERHTPEMRHWXVMEPKVEHIGIPPQSHIQSVWWXIQWTXSQMGVSMRIVXIVW %EMPEFPIMRXLI9'EREHE1IMGS4IVXS6MGSERHXLI9:MVKMR-WPERHWLIVIXLIVIMWEHIUEXIGIPPPEVWIVMGIMR theinstallationarea.)IncludesasilversolarshieldtomatchtheIQBatteryandIQSystemControllerandtodeectheat. RSXMRGPHIHSVHIVWITEVEXIP )RWIQFPI'SQQRMGEXMSRW/MX '11')001()11 ')001()114 ')001()11%8 -RGPHIW'11/-8ERH')001()114MXLIEVTVMRXHEXETPERSV )RWIQFPIWMXIW +FEWIH08)1GIPPPEVQSHIQMXLIEVTVMRXHEXETPER +FEWIH08)1GIPPPEVQSHIQMXLIEV%88HEXETPER 'MVGMX&VIEOIVW &6/%: &6/%: &6/%4: &6/%4:& &6/%4:& SupportsEatonBR210,BR215,BR220,BR230,BR240,BR250,andBR260circuitbreakers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x49.5x16.8cm(14.75”x19.5”x6.63”).Heightis21.06"(53.5cm)withmountingbrackets. IMKLX 7.5kg(16.5lbs) %QFMIRXXIQTIVEXVIVERKI 'XS'XS 'SSPMRK 2EXVEPGSRIGXMSRTPWLIEXWLMIPH )RGPSWVIIRMVSRQIRXEPVEXMRK Outdoor,NRTL-certied,NEMAtype3R,polycarbonateconstruction MVIWMIW %XS%FVIEOIVMRTXWXS%+GSTTIVGSRHGXSVW %FVIEOIVFVERGLMRTXXS%+GSTTIVGSRHGXSVW 1EMRPKGSQFMRIHSXTXXS%+GSTTIVGSRHGXSVW 2IXVEPERHKVSRHXSGSTTIVGSRHGXSVW %PEWSPPSPSGEPGSHIVIUMVIQIRXWSVGSRHGXSVWMMRK %PXMXHI 8SQIXIVWIIX -RXIKVEXIHMM FKR 'IPPPEV ')001()114')001()11%8+FEWIH08)1GIPPPEVQSHIQ2SXIXLEXER)RTLEWI 1SFMPI'SRRIGXGIPPPEVQSHIQMWVIUMVIHSVEPP)RWIQFPIMRWXEPPEXMSRW )XLIVRIX Optional,802.3,Cat5E(orCat6)UTPEthernetcable(notincluded) 'SQTPMERGI-5'SQFMRIV UL1741,CAN/CSAC22.2No.107.1,47CFR,Part15,ClassB,ICES003 4VSHGXMSRQIXIVMRK%2-'EGGVEGGPEWW4:TVSHGXMSR 'SRWQTXMSRQIXIVMRKEGGVEGGPEWW 'SQTPMERGI-5+EXIE90'%2'%2S EI-QMIRELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSAC COMBINER CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSAC DISCONNECT CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Ketay, Sarah67 Franklin StNorthampton, MA 0106010/06/2022SUBMIT FOR PERMIT