Loading...
46-046 (3) BP-2022-1319 121 ISLAND RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 46-046-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2022-1319 PERMISSION IS HEREBY GRANTED TO: Project# PELLET STOVE Contractor: License: Est. Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp. Date: 01/06/2024 Use Group: Owner: SARGENT CATHERINE E Lot Size (sq.ft.) Zoning: SC Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON: 10/13/2022 TO PERFORM THE FOLLOWING WORK: PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: II f 6 >9 . i • Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner TH M _, City of Northampton . �Via, ti ,�,�i.�. _- ,.... Si . ,''`! = Massachusetts ���,'� ws' cl{f �_ * -.* } w �,s ii ( DEPARTMENT OF BUILDING INSPEC12p1PS ii. q , ' 212 Main Street • Municipal Building / 2 20 yJ ,_` �a �:..,r� +G �' Northampton, MA Ologo �� r�i ;"rjS1A~ " nT Atg)-i`V(3/NSFFY APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: (t/A S',e rq<,,f Address: /a/ y;/,tr , N oci Mrnp 74cn l/ll t' (No.) (Street Address) Phone: 4I3 3r9 ..'S• Cell: Email: ctTS4i7c e J tiro. Caryl Owners Signature: K--4 Date: tit y- Contractor's Information (If Applicable) Name: D i1,74} L 44her Phone: 1f3 3 97 31V6 S Construction Supervisor's License #: ham'/ Expiration: 7- .;(1 Home Impr. Contractor License #: /10y77 Expiration: //- to Stove Information Type of Fuel (check all that apply): Wood Pellet "� Coal Location: 4.,54 C/air Freestanding c Insert Manufacturer: - rni d� ,n s ��i '` ��� Model: st3 ve- f 44.A are/ _-__--------w------ —FOR BUILDTh G DEPARTMENT USE ONLY-------------____—__---_ Permit# 30 )-}-13Wevis.> L '7 Date Applied: - Total all Fees: $ /40 c/C/f/3 6.?d? Building Official: IC)55 Date Issued: ID-I3- 'PZ2 (Print) /Xis Signature of Building Official: . — d LSG VVLLLLL.LILL rrc.. LO/6 lei jr.M.LJ.YLL..r66..OLi6LJ --..,.--.5,. Department-' Department of Industrial Accidents T ;;: Office of Investigations j =T�' Lafayette City Center :7' 2 Avenue de Lafayette, Boston,MA 02111-1750 .;':.` ' HJUMmass.g(I U/dl(f Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers kpplicant Information Please Print Legibly flame (Business/Organization/Individual):THE FIRE PLACE .ddress:100 STATE ROAD 1 :ity/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463 re you an employer'? Check the appropriate box: Type of project(required): 111 I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors f ❑New construction1 ❑ i am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' y ❑ Building addition [No workers' comp.insurance comp. insurance.t 10.❑ Electrical repairs or additions required.] 5. ❑ We are a corporation and its [11 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.E Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.❑ Other , comp. insurance required.] ,y applicant that checks box#I must also fill out the section below showing their workers'compensation policy infonnation. omeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. Intractots that check this box must attached an additional sheet showing the name of tits sub-contractors and state whether or not those entities have 'loyees. If the sub-contractors have employees,they must provide their workers'comp.policy number. ru On employer that is providing workers'compensation insurance for my employees. Below is the policy and job site Drat ati on. turance Company Name:MA RETAIL MERCHANTS WC GROUP INC liey#or Self-ins. Lie. #:01400503301116 Expiration Date:1-1//-23 b Site Address: /.�_( . . -5447) 17 City/State/Zip: .Ic/Or/or1P 7/011 OA° ci"7 :tacit a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). ilure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a le up to S 1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and ti tine up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of vestigations of the DIA for insurance coverage verification. to hereby certif i uler the pains mu cnalties ofpe►juiy that the information provided above is true and correct. atgmature: ,�� -C Date: '/O' 3•-2� come#: 413-397-3463 • Official use only. Do not write in this area,to he completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 10Board of Health 20 Building Department 31:1City/Town Clerk 4.0 Electrical Inspector 5❑Plumbing Inspector 6.0Other Contact Person: Phone#: _ 1 3 Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. P43-C Freestanding Pellet Stove P61-C Freestanding Pellet Stove . l' OM . outside outside 777��� Air Intake "-` Air Intake N " `� 11 ,,,„Al 'koi) -III -k4.) ' `1 rn b p 51/8• 51/8• 22" 231/2"- IIII- � e ` �' JJv 4V vvv •� rati to El I 6 zo N 1t-1____,_ . I - ,- - 20 3/4" • P68-C Freestanding Pellet Stove "---r ______U Outside Air Intake\' i I enIIJ4U er 51/4•--r-- 23-1/2'---1 0 O 9 I, wy �VVV^VVV-V Y e 0 Zo M 4 o, 1111 C , -, I ; I i Figure 3.1 8 Harman® • P-Series Installation Manual R4 • 2018- • 04/21 8390-0441 B. Clearances to Combustibles Place the stove away from combustible walls at least as far When selecting a location for the appliance it is important to as shown in Figure 3.2. Please note the difference in side consider the required clearances to walls, Figure 3.2. wall clearance with and without side shields. Note that the clearances shown are minimum for safety but do A WARNING not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. RISK OF FIRE OR BURNS! Provide adequate Due to high temperatures,the stove should be placed out of clearance around air openings and for service traffic and away from furniture and draperies. access. Due to high temperatures, the appliance should Children and adults should be alerted to the hazards of high be located out of traffic and away from furniture and surface temperatures and should stay away to avoid burns draperies. to skin and/or clothing. Young children should be carefully supervised when they are ACAUTION in the same room as the stove. Clothing and other flammable materials should not be placed THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE. on or near this unit. NOTICE:Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.Actual installation may vary due to individual design preference. P61-C & P68-C Freestanding Pellet Stove P43-C Freestanding Pellet Stove 14"(355mm)with 2"(51mm) 2"(51mm) *10"(254mm)with , side shields 0 side shields �� 20"(508mm) *16"(406mm) without side shields o 14"(355mm) without side shields o _'10"(254mm) 20"(508mm) *16"(406mm) L. J�� *�tl• 36"(914mm) 36"(914mm) 9"(228mm)- 9"(228mm) 13"(330mm) o r + c0 w 3 w c 3 9"(228mm)With Side Shields 3 `1 13"(330mm) Without Side Shields 3 9"(228mm) With or Without Side Shields I Figure 3.2 9 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 C. Floor Protection Corner Installation: Parallel Installation: Minimum size floor protection for a corner installation hearth pad is: Place the stove on a noncombustible type floor or floor P43-C - Minimum size floor protection is 25-7/16" Wide by protector that extends a minimum of 6 inches (152mm) to 26-3/4" Deep (646mm X 680mm). the front of the load door opening, 6 inches (152mm)to the sides of the door opening, and 6 inches to the rear. P61-C - Minimum size floor protection is 25-1/8" Wide by The P-Series does not require R value floor protection. 27-3/4" Deep (638mm X 705mm). The minimum floor protector material is 20 gauge sheet metal. P68-C - Minimum size floor protection is 25-3/16" Wide by Other floor protector materials that can be used include Type 27-3/4" Deep (640mm X 705mm). I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3 Note: Floor protector WILL NOT touch the wall using *Floor protection dimensions for the front and sides are minimum clearances. measured from the appliance door opening in The United If corner floor protection is desired to touch the wall, the States. In Canada,the side dimension is measured from the floor protection will need to be at least 40" x 40" (1016mm widest part of the appliance. x 1016mm). Note: This will allow the floor protection to P43-C - Minimum size rectangular floor protection is 25- touch the wall as shown. Figure 3.4. 7/16"Wide by 26-3/4" Deep (646mm X 680mm). Alternate floor protector dimension may be used as long as P61-C-Minimum size rectangular floor protection is 25-1/8" they satisfy the measurement requirements shown below. Wide by 27-3/4" Deep (638mm X 705mm). P68-C - Minimum size rectangular floor protection is 25- 3/16"Wide by 27-3/4" Deep (640mm X 705mm). Venting: -Follow PL vent manufacturers recommendations when configuring vent pipe installation. . 11111111111171.\. Canada- Must extend 2" (51mm) beyond each side of any horizontal flue pipe. O O L 0 Figure 3.4 D. Mobile Home Installation When installing this unit in a mobile home, several requirements must be followed: J Floor Protector 1. The unit must be bolted to the floor. This can be done K using an appropriate fastener for the application. Figure 3.3 2. The unit must also be connected to oJtside air. See "Termination Location and Vent Informat on"Section D. Floor Protection US Canada 3. Floor protection and clearances must oe followed as Requirements shown. J Sides 6" 152mm 4. The appliance must be properly grounde to the frame of K Front 6" 152mm the mobile home using a minimum of 8 A G copper solid L Rear 6" 152mm or stranded, insulated or bare wire or eq ivalent. 10 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 4 Termination Location and Vent Information A. Vent Termination Minimum Clearances Note: Follow venting manufacturer's recommendations for sealing pipe joints. #1 Preferred method (Figure 4.1) This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall. Two inches from the wall is safe; however, four inches allows better access to remove the rear panel.The vertical portion of the vent should be three to five feet high.This vertical section will help provide natural draft in the event of la power failure. Do not place joints within wall pass-throtbgh. re rt 3 toFt. Combustibles Ire,/.1.40 d ` . 3 Ft. to Combustibles Figure 4.1 #2 Preferred method (Figure 4.2) This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least 1" from a combustible wall. This vertical section will provide natural draft in the event of a ' power failure. If the stove is installed below grade be sure the vent �1� termination is at least 12"above grade. The outlet must also � be 1 foot from the house/building. 3tot' Do not place joints within wall pass-through. Combustibles /0100000,1 I A CAUTION Keep combustible materials (such as grass, leaves, 151 � etc.) at least 3 feet away from the flue outlet on the outside of the building. , Il IIIIl /J HI3 Ft. to Combustibles Figure 4.2 11 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441