Loading...
824 Ryan Rd Electrical Permit AppInstallkW solar on roof. ( ) panelsInstallkW solar on roof. ( ) panels INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 RYAN ROAD P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL- ADD- ON TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY: DC SYSTEM SIZE:14kW AC SYSTEM SIZE:11.4kW MODULE COUNT:35 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 14 PITCH: 25 ORIENTATION: 80 ROOF 2 MODULES: 16 PITCH: 25 ORIENTATION: 260 ROOF 3 MODULES: 0 PITCH: 28° ORIENTATION: 40° ROOF 4 MODULES: 0 PITCH: 30° ORIENTATION: 350° ROOF 5 MODULES: 0 PITCH: 28° ORIENTATION: 220° ROOF 6 MODULES: 0 PITCH: 28° ORIENTATION: 310° ROOF 7 MODULES: 5 PITCH: 25 ORIENTATION: 260 ROOF 8 MODULES: 0 PITCH: 25° ORIENTATION: 80° ROOF 9 MODULES: 0 PITCH: 30° ORIENTATION: 170° ROOF 10 MODULES: 0 PITCH: 24° ORIENTATION: 80° ROOF 11 MODULES: 0 PITCH: 24° ORIENTATION: 260° ROOF 12 MODULES: 0 PITCH: 28° ORIENTATION: 130° ROOF 13 MODULES: 0 PITCH: 28° ORIENTATION: 261° ROOF 14 MODULES: 0 PITCH: 23° ORIENTATION: 170° ROOF 15 MODULES: 0 PITCH: 23° ORIENTATION: 350° ROOF 16 MODULES: 0 PITCH: 20° ORIENTATION: 261° ROOF 17 MODULES: 0 PITCH: 20° ORIENTATION: 81° ROOF 18 MODULES: 0 PITCH: 6° ORIENTATION: 81° ROOF 19 MODULES: 0 PITCH: 28° ORIENTATION: 78° DC ACD DC AC D UD epM NS27090 1 3 5 2254531542.310716,-72.704027 35 HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400) 1 SE11400H-US0SHBNC4 IN BASEMENT OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL- ADD- ON TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY: DC SYSTEM SIZE:14kW AC SYSTEM SIZE:11.4kW MODULE COUNT:35 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA P1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 6 CCC: 0.80 (40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 47.50A*1.25 = 59.38A AWG #6, DERATED AMPACITY AMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 75A*1.0 = 75A 75A >_ 59.38A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 47.50A 47.50A*1.25 = 59.38A --> 60A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING LOCKABLE 60A DISCONNECT FUSED W/ 60A FUSES SQUARE D PN: D222NRB ISOLATED NEUTRAL 240V 1Ø EG NOTE: INTERNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-3D-240-MB INVERTER #1 - SE11400H-US0SHBNC4 DC AC Imp 30.5 Pout 11400 Vmp 400 Imax 47.5 Voc 480 OCPDmin 59.38 Isc 45 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400) Imp 10.77 Vmp 37.13 Voc 45.3 Isc 11.14 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 6-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 6-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-C SOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS 35 - 400W MODULES W/ 1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING 2 STRINGS OF 12 MODULES IN SERIES - 400 Vmax 1 STRING OF 11 MODULES IN SERIES - 400 Vmax *3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 8"x8" JUNCTION BOXf SOLAR MODULES MOUNTED TO ROOF ON 4 ARRAYS 19 - 340W MODULES W/ 1 SOLAR EDGE P340 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 11 MODULES IN SERIES - 380 Vmax 1 STRING OF 8 MODULES IN SERIES - 380 Vmax *2 STRINGS TERMINATED IN PARALLEL INSIDE EXISTING INVERTER EXISTING 5K INVERTER PV+L1 L2 N PV-EXISTING 6.46kW PV SOLAR SYSTEM ***NOTE: NEW USAGE REPORTS WARRANT AN INCREASE IN PV BACK FEED. SYSTEMS SHALL REMAIN SEPARATE TO SIMPLIFY MONETARY / REBATE FORMS SQUARE D DU222RB 60A UNFUSED DISCONNECT ISOLATED NEUTRAL 240V 1Ø NEUTRALMEXISTING 120/240V UTILITY METER 2p200AMAIN240V 1Ø 200A MAIN BREAKER 200A BUSBAR EXISTING MAIN BREAKER LOAD CENTER INSULATED LINE TAPS INSTALLED ON MAIN FEEDERS NEC 705.12(A) LOCKABLE 60A DISCONNECT FUSED W/ 60A FUSES SQUARE D PN: D222NRB ISOLATED NEUTRAL 240V 1Ø P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL- ADD- ON TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY: DC SYSTEM SIZE:14kW AC SYSTEM SIZE:11.4kW MODULE COUNT:35 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 5/13/2022 Arthur J.Gallagher Risk Management Services,Inc. 4000 Midlantic Drive Suite 200 Mount Laurel NJ 08054 Mark Grasela 856-482-9900 856-482-1888 CherryHill.BSD.CertM@AJG.com Gotham Insurance Company 25569 TRINHEA-03 National Union Fire Insurance Company of Pittsburg 19445TrinitySolarInc. 4 Open Square Way,Suite 410 Holyoke,MA 01040 Liberty International Underwriters 1260165960 A X 2,000,000 X 100,000 5,000 1,000,000 2,000,000 X GL202100013378 6/1/2021 6/1/2023 2,000,000 B 2,000,000 X CA 2960145 6/1/2022 6/1/2023 A C C X 5,000,000 X EX202100001871 ELD30006989101 1000231834-06 6/1/2021 6/1/2022 6/1/2022 6/1/2023 6/1/2023 6/1/2023 5,000,000 Limit x of $5,000,000 19,000,000 B XWC135881086/1/2022 6/1/2023 1,000,000 1,000,000 1,000,000 B Automobile Comp/Collusion Ded.CA 2960145 6/1/2022 6/1/2023 All Other Units Truck-Tractors and Semi-Trailers $250/500 $250/500 Evidence of Insurance. Evidence of Insurance JOB NAME:APOLINARIO, JILL- ADD- ON ADDRESS:824 Ryan Road Northampton, MA 01062 42.310716,-72.704027 79 ESTIMATED PERSONNEL HOURS 3.29 DAYS 2.47 DAYS 1.65 DAYS •35 HANWHA 400's (14KW)(CREW OF 3)(CREW OF 4)(CREW OF 6) •3 SEPARATE ARRAYS •20' PEAK TO GROUND •33 PORTRAIT & 2 LANDSCAPED •1 INVERTERS INSTALLED OUTSIDE •NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400)35 ______ □S440 SE OPTIMIZERS 35 ______ □SE11400H-US0SHBNC4 1 ______ □60A OUTDOOR FUSED DISCONNECT W/ (2) 60A FUSES 1 ______ □60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)3 ______ □PV LEAD WIRE 150'______ □INSULATED BUG BITES (LINE TAPS)2 ______ □CASE(S) OF BLACK SPRAY PAINT 1 ______ □CASE(S) OF TAR 1 ______ □FLASHINGS ______ MATERIAL LIST R(FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 824 RYAN ROAD APOLINARIO, JILL- ADD- ON 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 R APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com