Loading...
18C-067 (3) BP-2022-1107 203 PROSPECT AVE COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 18C-067-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1107 PERMISSION IS HEREBY GRANTED TO: Project# 2022 CHIMNEY RE-LINE Contractor: License: Est. Cost: 6962 CORY MCGILL 107658 Const.Class: Exp.Date:05/25/2023 Use Group: Owner: MIKIC BORJANA Lot Size (sq.ft.) Zoning: URB Applicant: CORY MCGILL DBA DONE RIGHT CHIMNEY Applicant Address Phone: Insurance: PO BOX 1054 (413)340-1399 WCV 01525601 WILLIAMSBURG, MA 01096 ISSUED ON:09/08/2022 TO PERFORM THE FOLLOWING WORK: INSTALL METAL CHIMNEY LINER KIT TO VENT OIL BURNER POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 52 3s) ,A5017' Fees Paid: $65.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner r -- .n rr The Commonwealth of Massachusetts * Board of Building Regulations and Standards FOR MUNICIPALITY Massachusetts State Building Code, 780 CMR USE 1a" I Building Permit Application To Construct,Repair, Renovate Or Demolish a Revised Mar 2011 2 One-or Two-Family Dwelling ?= r • 1 This Section For Official Use Only - .,,Building PermitNumber:i'3?2,02:2,-iIO7 Date Applied: r/ ' 4107Z ,/Ls� 9-7-2022 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 203 Prospect Avenue,Northampton,MA 01060 IBC-- 06 7—00 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard i Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Borjana Mikic Northampton, MA 01060 Name(Print) City,State,ZIP 203 Prospect Avenue (413) 320-3222 borjanamikic123(c�gmail.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other El Specify: Chimney Re-linting Brief Description of Proposed Work':To line existing masonry chimney with a custom ovalized,316 stainless steel tee liner kit to vent existing oil burner.NFPA Level 2 Inspection has already been completed by Done Right Chimney. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $6,962.25 1. Building Permit Fee: $ Indicate how fee is determined: • 2. Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier h✓) 1 n, x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire o. Suppression) $ Total All Fees: $ (p 6— v PP ) Check N 2 7 Check Amount: /, Cash Amo t: 6.Total Project Cost: $6,962.25 ❑Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-107568 05/25/2023 Cory McGill License Number Expiration Date Name of CSL Holder List CSL Type(see below) U P.O. Box 1054 No.and Street Type Description Williamsburg, MA 01096 U Unrestricted(Buildings up to 35,000 cu.ft.) City/Town,State,ZIP R Restricted 18E2 Family Dwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances (413)340-1399 ContactDoneRight@gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) #178722 Cory McGill 08/ 7/2024 HIC Registration Number Exp' lion Date HIC Company Name or HIC Registrant Name P.O. Box 1054 ContactDoneRight@gmail corn No.and Street Email address Williamsburg. MA 01096 (413)340-1399 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No ❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Cory McGill to act on my behalf,in all matters rela 've to work authorized by this building permit application. Borjana Mikic ...ssi� 09/02/22 Print Owner's Name(Elec"mac .i.'' Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Cory McGill � 07/0-/afa Print Owner's or Autho ' Agent's Name(1onic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I t acknowledge at as � a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a proberly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 203 Prospect Avenue, Northampton, MA, 01060 The debris will be transported by: Done Right Chimney The debris will be received by: Valley Recycling, 234 Easthampton Rd, Northampton, MA 01060 Building permit number: Name of Permit Applicant Cory McGill dba Done Right Chimney mA-a/)9- Date Signature of Permit Applicant The Commonwealth of Massachusetts Department of Industrial Accidents e= Office of Investigations — 1 gem. Congress Street, Suite 100 ' Boston, MA 02114-2017 Atwell" www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Done Right Chimney Address:P.O. Box 1054,45 Main Street, Unit B City/State/Zip:Williamsburg, MA 01096 Phone#: (413)340-1399 Are you an employer? Check the appropriate box: Business Type(required): 1.0 I am a employer with'.3 employees (full and/ 5. a Retail or part-time).* 6. ❑ Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl.real estate, auto,etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.❑ Manufacturing no employees. [No workers' comp. insurance required]** 11.❑ Health Care 4.❑ We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp. insurance req.] 12.0 Other Services: Chimney&Hearth *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:Atlantic Charter Insurance Company Insurer's Address:45 Main Street,Unit B City/State/Zip: Williamsburg, MA 01096 Policy#or Self-ins. Lic.# WCV 01525601 Expiration Date:06/28/2023 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certi ,un er the pains and penalties of perjury that the information provided above is tr e and correct Signature: Date: 01/0)-- Phone#: 13) 340-1399 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.mass.gov/dia MEMO INSTALLATION INSTRUCTIONS Phone:888-900-8106 FOR BEST-Flex Models "L", "H", "S", & "E" Fax:888 392-4432 IMO il IMO OM IN Ih. � Web:�� www.NewEnglandChimneySupply.com STAINLESS STEEL CHIMNEY LINERScc • 34 Commerce Street,Williston VT 05495 BEST-Flex Models ii �� Li �� cc �� BB51► " L , H , S , & E FLEX New E n g I a n d Supply PRODUCTS STAINLESS STEEL CHIMNEY LINERS BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,I,VT. The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys. BEST-Flex liners are used to vent the gages and by-products produced by appliances that burn oil,gas,or solid fuels. All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance. The installer must contact the local building and fire code officials for a variety of reasons: • The installation may require special inspection requirements. • Building permits may be required before installation. • Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and Fire Bureau's have precedence over national codes). For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials ndt specified may result in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not followed BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories. • In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys. • In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys. PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS • The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new cipnstruction. Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation. BEST-Flex can be used to vent wood,wpod pellet,coal, non- condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available irj 3"to 12"diameters (13"above is not listed)to cover a wide range of requirements found in the field today. • The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked an crimped to produce a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimn�ys and can be factory ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be fie d ovalized. The corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stres es on the system. • BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635 standards for chimney exteriors with zero clearance to combustibles. • BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 perceInt or lower. MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION: Liner Model-"L", "H","S",&"E" ^- TT/TB-Two piece or one piece tee f. TEC-Tee Cap EA/EF- 15°-90°elbow • di 11 • # • ! 1 y .� C/CC-Coupler '� Screws/Rivets OPTION A 0 -t"° OPTION B ir Alis,, TP-Top Plate `'"ITPCC-Liner Cap TC-Top ClampjR"Or TPC.Top.Plate OR SC-Storm Collar '``� CL- Liner Cap(square/round) • --�"\ t INSULATION MATERIALS REQUIRED(if applicable) Part# Description LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket s'i LM Liner Mesh Protective Wire Mesh Sleeve . '` FT(2", 3") Aluminum Foil Tape ::z LMC(large/small) Mesh Clamp , �. BMIX BEST Mix 11111111111111111001111 • / Phone:888-900-8106 ,,,,,,,, j,././t Fax:888-392-4432 Web:www.NewEnglandChimneySupply.com New England Supply 34 Commerce Street,Williston VT 05495 1.)CHIMNEY PREPARATION&INITIAL INSPECTION Before any liner can be installed the existing chimney must meet proper construction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material.If the chimney is constructed on the outside of the structure, 1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with all local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is Installed.A full inspection must be done to determine if the chimney is structurally sound. If the existing system is found not to be in compliance with applicable building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring the chimney or vent into compliance with the applicable code and I or manufacturer's instructions. Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original chimney or vent in which it is installed. CHIMNEY CONNECTORS AND VENT CONNECTORS 2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER krwun chimney daamoa System A.Minimum 3.5In.()0 ram)thick brick masonry wad framed into • Any heating appliance connected to the lining system must not bbntlurow!aeaaw� ,,,raw amim.�a12i (305mm)ondk�epe�ahn 2.(51 nth) a aueraan clearance from clay liner to combustUea.Findley liner(ASTM C 315 have a flue outlet size larger than the liner area at its smallest _Z. C 12In(335mn) g Standard Specification for Clay Flue Liners and Chimney Pots,or equivalent), point,unless aqualifiedperson has sized the liner to suit the ' aw """ minimum fain(16mn)wa°"rd`ness sha°"nfmrna"ersurface T=• of brick wad to,as not beyond,me inner surface c diimney fare appliance , •---- _.. . liner and shad be amity cemerped n place. arm • For sizing a liner used for gas and oil burning appliances referan kw 1.an ma wnn.ev Clearance--12 in.(305 nun) to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the t,.,,,,12a„3o6-) ,,,,,,t �te/ I w"" appliance manufacturer's instructions.Liners that are incorrectly bcanA meta d,e"ab 11F7A 2n sized for the appliance can lead to poor draft,excessive condensation,and creosote build-up inside the lining system. Minn dimlydamp ken d MMmm Syswoe.Soli�osalared,listed aantor,'-bk°"chi n ylengthetthesa'ne raasmay m4pm+a inside25 catheter as fno chimney with a minor and MVYIO 1 in. Please call New England Supply Inc.shouldyou have anyco.— 1.2 e.rat 1nn) + wars• 25mm ormoreof insulamney connector and 9ln.229mm) 9 PP Y \ i 9,n(229 ram, air spare between the outer(wall of the chimney length and questions about sizinga liner. Finao ybdt • cur„eY combustibles oemay 0np went MI •-- co,soomr The Inner end or the chimney length shall be flush with the • For sizing a liner used for solid fuel burring appliances the cross ,,u inside of the masonry chimney flue and shall be sealed to the flue section area of the liner shall not be less than the cross section I e+" 11' and to the brick masonry penetration with non-weleresoluble a nw -_ ) use chimney refractory cement.Supports shall be securely fastened to wall more.pans to surfaces on all sides area of the appliance outlet collar.Unless specified by the ilk pew il: 4Wit'o nemr Fasteners between supports and the chimney length shad not a n.Wimp.. e„sy - mom* penetrate the chimney liner. appliance the cross section area of the flue shall not be more than S,,,d,,,,,leted, three(3)times the cross section area of the appliance outlet collar. ' "K,,° 211 Glemande'9 in.(229mm) Solid fuel burning fireplace liners should be a minimum of one- Sheet awlatpppna twelfth(1/12)the square inches compared to the square inches of the fireplace opening.This one-twelfth(1/12)number can Mewnm chimney drarr-br-—, Systems.Sheet steel cr,Melay connector.minimum 24 gauge)o.024in stall supports and canbuWtr �., (0.61 mm))in thickness.With a ventilated Mande.minimum vary based on height of the chimney along with other calculating 2 in.(Slmm) Teae0aw+x• 24 gauge[0.024in(0.61nrn))in thickness,having two 1in. factors.Call New England Supply Inc.if you have any questions. ma aa�'e(25mn) (25u n152esir nels,ss tedh°m`ombustiblesbyaminimum sere ` I> 6 in.(152 ram)of glass fiber insulation.Opening shall be covered, �'1 0nn•W and thimble supported vn(ha sheet steel support,minimum 24 gauge (�\.�J OM co'""01" (o.oze in.(oven ram))in fhickrr055 •- Supports shad be sedum fastened to wad surfaces on all sides 3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO ��� end shall be sized to fit andhholdchimneysedan.Fastenersused (7Nnry -I t.film to secure chenney section Shall not penetrate chimney flue liner. THE CHIMNEY Twa,.�t.w all no. (162 mm)gin mewl.xdt 1 E4 Clearance--6 in.(152 mml • The BEST-Flex Stainless Steel Chimney Liner can be installed th(Ysmm): ym.•y y inside the existing flue tile or the flue tile can be removed.It :aala4"*. dame aw�b"NFAa2ff Sheet feet swag is critical that the correct size liner will actually fit into the flue. Chimney construction and flue offsets may change the physical Sankt.chimney dn.neto snort meis t,and System o.Said-alsulated listed fadpry-enid chimney length with an inside wr4rma 2 in(5t mm) diameter 2 in.(51 ram)ler r than the chimney connector and having size of the interior of the chimney.It is best to test the smallest ; 1 (25 ran)or more ofn o4ation.serving as a pess-through for a single k ,. •+••l i lamem demos.2 in.(Si null wall sheet steel chimney cyn ector of ndneraan 24 gips(0.024 in. point of the chimney interior before trying to install the chimney "me, 061 ram)thakness,w hie mmimum2in.(51 mm)air space between the e� dlear+by �.-v--- 10 chimney ce outer wall of chimney and cnnWsahha. liner.Lower a short piece of the correct size liner down the " Chan _, Minimum length pl chimney section shall oe+2 in.(3osma)Chimney chimneyIN to see if it will fit through,or a liner guide cone.If the � section concentric with and spaced l in(25 mm)away from connector by 9 means of sheet steel suppon plates on both ends of supported section. chimneyliner needs to be insulated extra space around the liner + - eb Opening shall be covered,and chimney section supported an both sides with t P --- . kit sheet steel supports of milamum 24 gauge(0.024 in.(061 ram))thickness is required.If a round liner configuration will not fit the liner can be IP Cwwwyeron Supports alloeaema,Y�sanadtpwadsena es onansides q 9 Air spa s 2 (5f mm) and shall be sized to fa and hold chimney section.Fasteners used formed into an oval shape to fit at the factory. However an oval Me-eydamby�' Shoot 0 0no ee to secure cturnete aedeoeetaa not penetra"chimney flue line` liner will change the cross section area and a larger liner may be ewe 2,1 Cleeranca:2 In.(51 mm) needed.Please call New England Supply Inc.with any questions. Note:All clearances and thicknesses are minimums:larger clearances and tacknesses are permitted. 4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER • Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the a liance. The liner length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately S (6)inches to attach the crown and top hardware.Cut the liner to the desired length. • If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed nd,or stainless steel screws(Male end down when applicable). • Attach the Tee Body to the liner with the affixed band,or stainless steel screws.If the liner needs to be insulated with a cera is wool blanket,install the blanket at this point. Attach the Tee Cap to the Tee Body at this point. • Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the ue.Lower the liner