Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
22B-001 (4)
BP-2022-1044 206 SPRING ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 22B-001-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1044 PERMISSION IS HEREBY GRANTED TO: Project# 2022 SOLAR SYSTEM Contractor: License: Est. Cost: 47500 CLAUDIO GARRIDO CS-089458 Const.Class: Exp.Date:08/24/2024 Use Group: Owner: DOUGLAS SHAPIRO LOGAN Lot Size (sq.ft.) Zoning: WSP Applicant: CLAUDIO GARRIDO Applicant Address Phone: Insurance: 140 NASH HILL RD 4132195906 SOLE PROPRIETOR HAYDENVILLE, MA 01039 ISSUED ON:08/26/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 12.2 KW WITH UNSPECIFIED #OF PANELS GRID TIED ROOF MOUNTED SOLAR SYSTEM WITH BATTERY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: ‘ty,f4L.,._, .y9 cja,„17,, Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner , Pi c r The Commonwealth of Massach efts ,libit , Board of Building Regulations and an ds AUG MUNICIOR PALITY Massachusetts State Building Code, 80 R 2 3 .90' USE Building Permit Application To Construct,Reim' ,Ret�ar r Demolish a Revised Mar 2011 r. One-or Two-Family Dwellin NOr?7- 'O/c,. _ / This Section For Official Use Only / Building Permit Number: "a.. "'. ( C3� 5/1 Date Applied: /t i )1,-) '25.5 .//4Z 6 24,-ZDZ2_ Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1 opertLAAdd s: ^� 1.2 AssessorsMap&Parcel Numbers / 1.1a Is this ant acceptSd street?ee yes no Map ISumber Parcel lNumber 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Pro'ded 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal sYstem 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2 Owner' f Rjpg 9r Cc ('Yc. T H14 D l/Q‘2 Name,( Tint) ,, /> City,State,ZIP 206 S'p-1 SS, 'fig 5'5 3.3aS �pci 6lo fhe olR'Ncr`.1 �ems►- CONo.and Streit ( Telephone Email Address ,,Q c-o y,. SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) t�(�/I(i( New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work2: N be/ il pu 1'e / p a M ,c'1 P� 1G 6 cy � — SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ ''3. „cOO 0 Standard City/Town Application Fee 0 Total Project Costa (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $ Check No.?'3heck Amount: Y 6.Total Project Cost: $' 0 Paid in Full 0 Outstanding Balance Due: 1 , City of Northampton Massachusetts 'r i lfw 1C DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building Northampton, MA 01060 a s `lY 3`Y1A PROCEDURE FOR OBTAINING A BUILDING PERMIT FOR WINDOWS, DOORS, ROOFS,RENOVATIONS, ROOF MOUNTED SOLAR, ETC. 1. Building Permit Application signed by legal owner and filled out by owner or authorized agent. 2. One set of plans and specifications of proposed work (Digital and hard copy). 3. Construction Debris Affidavit filled out and signed by applicant. 4. Worker's Compensation Insurance Affidavit filled out and signed by applicant. 5. Contractors must supply a copy CSL, HIC, and proof of Liability Insurance. 6. Energy Conservation Compliance Certificate (new /replacement windows). 7. Home owner's License Exemption Form (if applicable). 8. Note any Special Permit requirements (if applicable). 9. Energy Code —all new construction (Gut/Rehab) requires a HERS Rater Affidavit 10. Please provide the appropriate fee in the form of a check made payable to: The City of Northampton. SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) tS_O 8rr5s?f� O� 9/, O e(1�D License Number Ex irra T1 Rlatioon Date Name of CSL Holder V/q 11 434 //I`& _n List CSL Type(see below) No.and Street (� Type Description l G` , Unrestricted(Buildings up to 35,000 cu. ft.) �v Restricted 1&2 Family Dwelling City TonState,ZIP / M Masonry RC Roofing Covering WS Window and Siding ,,nn ,A ,'7 J SF Solid Fuel Burning Appliances (4,42fl-5%6' C6- /1fu OW-06l/44(L.C. ITphone Email address D Demolition 5.2 Registered/ Home Improvement Contractor(HIC) �6 p(!/ 0., /„/�� CL�w,(c � fc PJ C Registration Number Exxpi ation Date HIC Company Name or HIC Registr t Name WIZ �Yo � f CG o 7-imoGia4d. No. d S et Email address • g14- (94937 01$0?---Circr( Ci /T wn,State,ZIP, Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .Z No . 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize ( 4 /4t �ld 4.44 Q( Q 6) to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Sign re) D e SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application i and a ate to the best of my knowledge and understanding. Print Owner's o Author e ent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" .6Ni.. The Commonwealth of:Vfassachusetts- ' Department of Industrial Accidents A ..„ 1 Congress Street,Suite 100 Boston, _I1-10114-2017 ww)i:nt ass.g ov/d i a it of-kers Compensation Insurance .%(lidos it:BuildersiContritetorsfElectricians/Plumbers. TO RE FILED WWII HE PERMITTING AUTHORITY. Applicant Information Please Print Leeibls r.A Name tRusiness:OrganizationiIndividual): Address: /Ve, 474-Qi (1(12 City/State/Zip: /-(4),A6 V ' ,. - Phone #:_6(.311/r— 3-Voc _ .'irt,,!.uu uni t sipiwyer,Check the appropriate but: Ii pe of project(required): 1.D I am a einploya with ernployces tfail allude/put-tins:I:" 7. 0 New construction i sin a sole proprietor or partoaship and have no employemt working for ow in 8. e3 Remodeling or—any capactry [No workers'comp.insumou: iruutrui 1 9 J Ikinolition 30 t XII a homeowner doing;IN wad strI.Arlf.[Nu workers'conm.irourance cequired_I I 0 building addition I am a homeowner aod will be hiring coraractors to conduct all%sort on tny property. I will cumin:that all contractors either hose Wasrkenk•OiSinipensiiisurt LnNur.uner or are Ask ii a Electrical repairs or additions proprietors with no employeini_ 12.0 Plumbing repairs or additions 501 am a general contractor and Ihree hired the ittb-contracrors fro on the attached sheet Ro "[Neve sub-euntractors have employees and have workers'comp.insurance.: 130 of repairs 14.C:I Other 6.0 We are a oxporation and ib officers have exercised thew right of exemption per MGL c. 152,§1t4),=dive have no entiployees.[No worken.comp.insurance registry:al •Aor.applik..wit that decks bet.1 Mika .1 i,c' :I,l,LI 1!:, .1'dun hick)*sharking their woriters•conlptmsArion pulley information. t kiL;IncoA matt who stahnut tuts affidavit Indic:Lung Liwy MC doing all work mid then here outside coritractors maw intrstit a new affidavit miiie.-Atang sts:h. -It-antra:tors that check this box,must att-ached un Arldiuunal"sheet shaming the name A.the su4.--einttnu:ters and'fate whether of nut those erfIllun List: tplo..,t..vs. If the sub-contractors lia,,e employees.they must priiiide their At.daers' ::I:1p. r0!1N.':!,number I am an employer that is providing workers'compensation insurance for my employees. Below iA the'whey and job Aire information. Insurance Company Name: _ Policy#or Self-ins.Lie.#: Expiration Date: Job Site Address: CityStateiZip: _. .. Attach a copy, of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable b:. .t firic up to$1.500.00 andeor one-year imprisonnient,as well as ,:ivil penalties in the form of a STOP WORK ORDER and a tine of up to S250.00 a day against the violator. A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance covera.4e verificatif)n. I rho hereby certili•under tire . AS at penalties r r ry that the infarmation provided above is true and correct. ... Sip:acute: , v. 11:11..' C.9 -P:2 1 i ,e)..1-Z- /,. Phoned: (y( 1 f l — 5% 6' Official use only. Da not write in this arra.to be completed by city or town official ( its or Town: Pur III&License# Issuing Authority(circle one): I. Board of Health 2. Iluildinv. Department 3.City/Town Clerk 4. Electrkal Inspector 5. Plumbing Inspector 6.Other ('ontact Person: Phone#: City of Northampton l• ' Massachusetts F t � DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building leg, Northampton, MA 01060 yst.•Fti, • ,.�_> CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: Vi/ K � �. (ifi(-- The debris will be transported by: • Name of Hauler: (�`�1'(/jPC� Signature of Applicant: Date: 2 City of Northampton • Massachusetts 44 )t DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building �b Northampton, MA 01060 HOMEOWNERS'EXEMPTION ELIGIBILITY AFFIDAVIT I, (insert full legal name), born (insert month, day, year), hereby depose and state the following: 1. I am seeking a building permit pursuant to the homeowners'exemption to the permit requirements of the Massachusetts State Building Code, codified at 780 CMR 110.R5.1.3.1, in connection with a project or work on a parcel of land to which I hold legal title. 2. I am not engaged in, and the project or work for which I am seeking the aforementioned homeowners' exemption, does not involve the field erection of manufactured buildings constructed in accordance with 780 CMR 110.R3. 3. I qualify under the State Building Code's definition of"homeowner"as defined at 780 CMR 110.R5.1.2: Person(s) who owns a parcel of land on which he/she resides or intends to reside, on which there is, or is intended to be, a one-or two-family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a home owner. 4. I do not hold a valid Massachusetts construction supervision license and, except to the extent that I qualify for and will abide by the Massachusetts State Building Code's requirements for the supervision of the project or work on my parcel, I am not engaged in construction supervision in connection with any project or work involving construction, reconstruction, alteration, repair, removal or demolition involving any activity regulated by any provision of the Massachusetts State Building Code. 5. If I engage any other person or persons for hire in connection with the aforementioned project or work on my parcel, I acknowledge that I am required to and will act as the supervisor for said project or work. Signed under the pains and penalties of perjury on this day of , 20 . (Signature) i N EE \ W H 1 � T " E August 11. 2022 —�% Structural&Civil Engineering g P.O.B.881 Tel:978-544-8000 Wendell,MA 01379 WhetstoneEng97@gmail.com Logan Shapiro 206 Spring St. Florence, MA 01062 • RE: 206 Spring St., Northampton Roof Structure: Project#22074 Mr. Shapiro, I visited 206 Spring St. to assess the capability of the existing roof structure's capability of supporting the additional dead weight of a solar panel system on the south gable. The original building has been augmented by the addition of an open porch along the south wall of the house. and also the reconfiguration of a portion of the roof so that the entire south gable lies on one plane. The roof appears true with no noticeable sags. The new work had been done in a professional manner. My analysis indicates the roof is capable of supporting the dead weight of the structure, the design roof snow load of 35 psf and an additional 5 psf of the solar panels. It is my opinion, based upon my training and experience as a professional engineer. as well as my site visit, the roof at 206 Spring Street with the additional weight of the solar panels meets the structural requirements of the Massachusetts State Building Code, Ninth Addition. Please call if you have any questions or concerns. Sincerely, • opt of giosi of ROBERT T Robert Leet, P.E. LEET STRUCTURAL 38942 t() ' QiSS[ S, A ►.. "300 .... e.)r; —,..... ..)-(a.r S-ct, T? cir- REVISION HISTORY 0 n,(^ REV DESCRIPTION DATE APPROVED wx`r�[J v 1 original drawing 12/11/20 SMS 2 revision OATS to ATS) 2/16/21 SMS t1 A 3 Added low voltage(CATS) 7/14/22 SMS .V,c.i—L W and CTs. Updated Module information. �ts roof mounted on Main Building J \\\ SMART meter socket Label.Utility production meter (240V 100A 1PN) Rapid Shutdown button Ink) with 100A Obi pole _`/ w zA r DC (NEC 011 7b compth PV uirey) coverbreaker under sperate (\. n oil EOM PV stay and cover. Energy storage system Ir S ...._ Grid to rkil-5 1. !<\)_y!,l 0 yam` ,r/� /yt � r r Mr --1I 11 1�4-'3 jQ�y�I f I 12345 12345 —N` I RSD kWh AiO (` kWn ' 1L-' LJ JLJUUUU K. I existing NG service (240V A 1PH) components located on west wall of main dwellin with 200A main breaker I 1 '� service entrance#10 PV wire)1000V)JY DC wiring box_„..----"----C Customers (Wiley box) Internet router CTs installed upstream of _ taps inside transfer switch • I Wee to CT terminals cede I transfer switch #8 THWN+red-blue 1 1 Point of Interconnection Use 1'EMT both inside and Generac PWRcell Battery Line cnde rap inside transter outside of building �IIII� s"' I rl l r G c�rsc*jr ow-- eATS r. 200A DC Disconnects(integrated in inverter) I 1 c. I II I I J rear,--- AC1 al:waX AC2 Main Generac PWRcell x7602 Inverter panel 240VAC 7 6kWAC wiblt-in ATS components located in basement of Main Building COLOR CODE black:previously existing components green:new to be installed components • CUSTOMER: Equipment pcs 'Make/Model Rating Comment .1, -.-..,,--,- grid-tied& Logan Shapiro Inverter 1,Generac PWRcell x7602 7.6kWAC;240VAC;32A;1111; UL 1741 SA;IEEE 1547(Rule 21&14H) Me aced5:50135-54033 PV Module 38 Peak Duo BLK-G10+ STC:Max Power 360W,Voc 41.18V;Isc 11.04A 5 strips of 8 modules grid-independent Meter#:52501356 Q SYSTEMS — residential Rapid shut down 40 Generac SnapRS Snap-RS802 Module level shut down on roof solar power —Storage battery 1 Generac PWRcell battery Useabel Energy 17.1 kWH;Nominal cont.power Storage configuration:Charging:Generation only/ Stbmired by SYSTEM ADDRESS: 6.7kW;nominal use energy hours:2.5hrs;annual Dischoging:Unrestricted to onsite loads and grid efan Maier-Domestic DC systems 206 Spring St /Discharge requirement 593 kWh/yr 166 Chestnut Hill Rd.-ORANGE MA 01364 Florence,MA 01062 ---- --- PHONE 978-424-5659 Automatic transfer 7TGenerac CXSW200A3 200A,120/240V,1 phase Open transition service rated,NEMA 3R enclosure EMAIL Stefan@domeskcDCsystems corn switch Page 2 of 2 UMZiP1VE COLLEGE FEDERAL CREDIT UNION P.O.Box 1060 Hadley MA 01035-1060 INTEREST CHARGE CO 'UTATION If you have a loan, the due dat:s on your statement may change if su are delinquent or if you are paid ahead. The amount of the FINANCE CHARt E on an open-end credit plan is . ermined by multiplying the daily balance in each loan account by the Daily Periodic 'ate. The daily balance s : I ,e computed by taking the beginning balance of each day, adding new advances, and su• racting any payments •r credits. Home Equity Loans & Lines of Credit, and Indirect Auto Loans -a late fee will be charge if full payment is ,ot r: eived within 15 days of the due date. All other Consumer Loans: a late fee will be charged if full .ayment is not -cei -d within 10 days of the due date. ABOUT YOUR OPEN-END CREDIT AC •UNT If you think your statement is wrong with rega•. to : loan transaction or if you need more information about a loan transaction on your statement, write us at U as 'ive College Federal Credit Union, 200 Westgate Center Drive, P.O. Box 1060, Hadley, MA 01035 as soon as .ossi-i e. We must hear from you no later than 60 business days after we sent you the first statement on which th- erro- or problem appeared. You can telephone us, but doing so will not preserve your rights. In your letter, give us t folio ing information: 1. Your nam: and .ccount number. 2. The doll r am. nt of the suspected error. 3. Descri.e the -rror and explain, as clearly as you can, why you believe there is an error. If yo need more information, describe the item you are not sure about. You do not have to ..y an amount in question while we are investigating, but you are still obligated to pay the parts of your statement tha are n in question. While we investigate your question, we cannot report you as delinquent or take any action to coll-ct the mount you question. powered by GLANTUM f Duo j© ._ 1 ;1 i S Q.PEAK DUO BLK-G10+ A COontrolledPV TUVRheinland 360 380 CERTIFIED ID v.coe, ID 1111232615 ENDURING HIGH YR 25 PERFORMANCE I,fJ EU Warranty CELLS 2021 pro &peda,,,y,c. Yield Security JJ'' BREAKING THE 21%EFFICIENCY BARRIER n 1 Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY -6Q CELLS is the first solar module manufacturer to pass the most compre- - hensive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY (� �:�": Optimal yields,whatever the weather with excellent U'�� low-light and temperature behaviour. ENDURING HIGH PERFORMANCE 0 Long-term yield security with Anti LID Technology,Anti PID I�/1 Technology',Hot-Spot Protect and Traceable Quality Tra.QTM1. �/ EXTREME WEATHER RATING High-tech aluminium alloy frame,certified for III III 4-1, high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT SEA Inclusive 25-year product warranty and 25-year YEARS linear performance warranty2. 6 BUSBAR 12 BUSBAR 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) CELL TECHNOLOGY CELL TECHNOLOGY 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR. "U/ r on :�sooftop cte in deniip �ul�.dings Engineered in Germany 0 CELLS MECHANICAL SPECIFICATIONS Format 67.6 in x 41.1in x 1.26in(including frame) (1717mm x 1045mm x 32mm) 380380'1980 mm)8,181 14.5'136e.5 mm) Weight 43.81bs(19.9kg) - Front Cover 0.13 in(3.2mm)thermally pre-stressed glass ~� with anti-reflection technology 4,c°wmg,°m..o.lr w.5 mm) -- x853'I115089.1 Back Cover Composite film 38s',10 mm 02.5 ) Frame Black anodized aluminum -.__.. .. 41 m.1.(1045m) Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71 in(53-101 x 32-60 x 15-18mm), use, .45.3'I3450mm8 Protection class IP67,with bypass diodes Cable 4mmz Solar cable;(+)a45.3in(1150mm),(+)>_45.3in(1150mm) 4i nien"A) 8.Damage notes Connector Staubli MC4;IP68 ' . . ' 4 t 1.26")32 mm) DETAIL 0.0T08mm1 0.837*21.25 mm)I I0.33')8.5 mm) ELECTRICAL CHARACTERISTICS POWER CLASS 350 355 360 365 370 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS. Power at MPP' PMPP [W] 350 355 360 365 370 Short Circuit Current' Inc [A] 10.97 11.00 11.04 11.07 11.10 E £ Open Circuit Voltage" Voc [V] 4111 41.14 41.18 41.21 41.24 c Current at MPP IMvr [A] 10.37 10.43 10.49 10.56 10.62 Voltage at MPP VMw [V] 33.76 34.03 34.31 34.58 34.84 Efficiency' r [%] >_19.5 >_19.8 >_20.1 >_20.3 >_20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.^.. . , Power at MPP PMPP [WI 262.6 266.3 270.1 273.8 277.6 E Short Circuit Current Inc [A] 8.84 8.87 8.89 8.92 8.95 E Open Circuit Voltage Moe [V] 38.77 38.80 38.83 38.86 38.90 Current at MPP IMRE [A] 8.14 8.20 8.26 8.31 8.37 Voltage at MPP Vm„ [VJ 32.24 32.48 32.71 32.94 33.17 'Measurement tolerances PH,±3%;Isc;Voc±5%at STC:1000 W/m2,25±2°C.AM 1.5 according to IEC 60904-3.2800 Wino.NMOT.spectrum AM 1 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE u+� -0GEu At least 98%of nominal power during llo ----- - - W M Indust,.amInd. .°air..wv..r' first year.Thereafter max.0.5 °¢,o le degradation per year.At least 93.5% w' of nominal power up to 10 years.AtLLi l00 F z least 86%of nominal power up to w o 25 years. e0• az 0 c All data within measurement toleranc- L. was es.Full warranties in accordance with e0. the warranty terms of the 0 CELLS 200 400 800 800 1000 c o• . sales organisation of your respective 2 o e ■ zo u ze ee country. is 'SW..lorm.a°u.....ame1om4,a,r,„.. YEARS Typical module performance under low irradiance conditions in now oman,merr n ws5 .,0..201.) comparison toSTC conditions(25°C.1000W/m5. IN 0 TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] ,0.04 p [%/K] -0.27 Temperature Coefficient of Pm„, y [%/K] 0.35 NMOT [°F] 109±5.4(43±3°C) c5 0 PROPERTIES FOR SYSTEM DESIGN o lL Maximum System Voltage Vs,s [V] 1000(IEC)/1000(UL) Fv. :.;1�c I::alRi1l Class II .71 Maximum Series Fuse Rating [A DC] 20 TYPE 2 Max.Design Load.Push/Pull3 [Ibs/ft2] 75(3600 Pa)/55(2660Pa) -40°F up to+185°F 0o Max.Test Load.Push/Pull' [Ibs/ft2] 113(5400 Pa)/84 Iz 000Pa) "'"' ,5.i ( 40°Cupto+85°C) 0 'See Installation Manual rn QUALIFICATIONS AND CERTIFICATES P. Quality Controlled PV-TUV Rheinland; 73 i IEC 61215:2016;IEC 61730:2016. w This date sheet complies A. with DIN EN 50380. Ge C E TUVa6.lmnq o til term),, U C Lk 61730 89 11112202, y Hanwha Q CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us GENERAC SnapRSTM 802 c t,s &ISTEO Intertek Genes ac ;.na RS ar<: mpie way To satlshI pid shutdcwn compliance for solar+storage systems. Generac SnapRS are 2017/2020 NEC 690.12 compliant, don't require any extra hardware to mount, and need no pairing or fussy digital communications. FEATURES & BENEFITS • Safe and reliable • Fast, easy, and simple to install • One SnapRS device per PV module • Achieves PVRSS Compliance • Low cost, high efficiency solution SYSTEM DESIGN Snap a Generac SnapRS disconnect device(RS)to the negative lead (-)of each module in the solar array for simple module-level rapid shutdown compliance.SnapRS devices isolate array voltage when a rapid shutdown is initiated at a PWRcell`"Inverter.When rapid shutdown is initiated, SnapRS units isolate each PV module in the array, reducing array voltage to<80V in seconds. ) R7RSRSj 3ENERAC IMMO PWRO r RS o■ + < RS RS RS Ep RS k I u u u u u r^ y PV Link1011 +1 � � I PWRceii Inverter Diagram is applicable for most 60 cell PV modules.Modules with higher cell count may require a different arrangement. Contact Generac for more details. .... Specifications ,,,...,,.,,...,......,.,..............,...,...,.......,..,,.,..,,,,.,,......,.,,,..,,,,..,..,.,.,.,,,..,..,.,..,,..,.........,..,.,., SnapRS (RS802) PV MODULE MAX VOC: 75 V EFFICIENCY: 99.890' MAX INPUT CURRENT: 15 A MAX STC ISC OF STRING: 12 A MAX TOTAL OTY IN SUBSTRING: 10 SHUTDOWN TIME: <10 Seconds ENCLOSURE RATING: NEMA 6P OPERATING TEMPERATURE- -40 to 158°F FAHRENHEIT(CELSIUS): (-40 to 70°C) CERTIFICATIONS: UL1741 PROTECTIONS: PVRSE WEIGHT-LB(KG): 0.17(0.08' 7"x1"x1" DIMENSIONS,L x W x H-IN(MM): (177.8 x 25.4 x 25.4) WARRANTY: 25 Years "When used with a 50V panel IConnect one SnapRS device to the negative lead of each PV module in the PV Link controlled array for complete PV Rapid shutdc.f -.•n -rmance: a „, A .. .. s s * � r A im y - � i ' -- ►- ice.. <�i/ e,, Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 www.GA00015 0570 comREV 888-GENERAC(436-3722) GENERAC® A0001520570 REV C ©2021 Generac Power Systems.All rights reserved. Specifications are subject to change without notice. GENERAACC PWRang • GENERAC< PWRIEED .0)1, us Intertek Solar+ storage is simple with the Generac PWRcell< Inverter.This bi-directional, REbus'-powered inverter offers a simple, efficient design for integrating smart batteries with solar. Ideal for self-supply, backup power, zero-export and energy cost management,the PWRcell Inverter is the industry's most feature-rich line of inverters, available in single-phase and three-phase models. FEATURES & BENEFITS • Single inverter for grid-tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User-selectable modes for backup power, self-supply,time-of-use, zero-import and export limiting • Free system monitoring included via PWRview'Web Portal and Mobile App AC OUTPUT/GRID-TIE MODEL MODEL DC INPUT MODEL MODEL X7602 X11402 X7602 X11402 CONT.GRID-TIED AC POWER a 50°C(122-F): 7600 W 11400 W DC INPUT VOLTAGE RANGE: 360-420 VDC AC OUTPUT VOLTAGE: 120/240,10 VAC 120/208,30 VAC NOMINAL DC BUS VOLTAGE: 380 VDC AC FREQUENCY: 60 Hz DC DISTRIBUTION INPUT BREAKERS: 4 x 2P30 A MAXIMUM CONTINUOUS OUTPUT CURRENT: 32 A,RMS MAX INPUT CURRENT PER DC INPUT: 30 A GROUND-FAULT ISOLATION DETECTION: Included REVERSE-POLARITY PROTECTION: Yes CHARGE BATTERY FROM AC: Yes TRANSFORMERLESS,UNGROUNDED: Yes THD(CURRENT): <2% TYPICAL NIGHTTIME POWER CONSUMPTION: <7 W TYPICAL NIGHTTIME POWER CONSUMPTION: <7 W DC BUS EXPORT FUSES I+/-): 40 A 2-POLE DISCONNECTION: Yes AC OUTPUT/ISLANDED IJ�ODF I MOUI l x 1602 X11.102 MODEL MODEL MAX.CONT.AC POWERW/SINGLE ' EFFICIENCY X7602 X11402 6 MODULE BATTERY CABINET': 9,000 W PEAK EFFICIENCY: 97.3% 97.7% MAX.CONT.AC POWER WITH 2 BATTERY CABINETS 11,000 W1 9,600-11,000 W' (8 MODULES MINIMUM)': CEC WEIGHTED EFFICIENCY: 96.5% 97.5% PEAK MOTOR STARTING CURRENT(2 SEC): 50 A,RMS AC BACKUP OUTPUT VOLTAGE: 120/240,10 VAC 120/208,10 VAC AC FREQUENCY: 60 Hz 'Peak Performance,values provided for 40"C(104"F) 2When islanded,continuous power output is restricted to 7.68kW unless backup THD(VOLTAGE): <2% power is routed through an external transfer switch. 'In Island mode X11402 protected loads only supply 2 phases 120 VAC L-N,208 L-L ALLOWABLE SPLIT PHASE IMBALANCE: Up to 30% which results in lower power than in grid tied 3 phase mode.The low value of the range is for full L-L loading while high value of the range is full L-N loading • \ Specifications ,..,,,,,,.,......,,.....,...,.,,,..,,....,................,..,...,,,..,...,,.,..,,..,,.,.,,..,..,......,....,....,,..,..,.,......... FEATURES AND MODES ISLANDING°: Yes GRID SELL: Yes SELF CONSUMPTION: Yes PRIORITIZED CHARGING FROM RENEWABLES: Yes GRID SUPPORT-ZERO EXPORT: Yes ESS PCS OPERATION MODES(IMPORT ONLY,EXPORT ONLY): Yes ADDITIONAL FEATURES SUPPORTED COMMUNICATION INTERFACES: REbus CANbus,Ethernet SYSTEM MONITORING: PWRview'"'Web Portal and Mobile App BACKUP LOADS DISCONNECT': Yes,50 A Circuit Breaker INVERTER BYPASS SWITCH: Automatic WARRANTY: 10 Years STANDARDS COMPLIANCE SAFETY: UL 1741 SA,CSA 22.2,UL 1998 GRID CONNECTION STANDARDS: IEEE 1547,Rule 21,Rule 14H,CSIP,UL 1741 PCS CRD(Import Only,Export Only) EMISSIONS: FCC Part 15 Class B DIMENSIONS AND INSTALLATION SPECIFICATIONS ENCLOSURE KNOCKOUTS-OTY,SIZE-IN(MM): 6 x Combo 112 x 1"(19 x 25.4) 7 x Combo /2"x 3/4"(12.7 x 19) DIMENSIONS LxWxH-IN(MM): 24.5"x 19.25"x 8"(622.3 x 488.9 x 203.2) WEIGHT-LB(KG): 62.7(28.4) COOLING: Forced convection AUDIBLE NOISE: <40 dBA OPERATING TEMPERATURE-FAHRENHEIT(CELSIUS): -4 to 122°F(-20 to 50°C)5 ENCLOSURE TYPE: Type 3R INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED: PWRcell"Battery MODULE STRING SIZE PER PV LINK OPTIMIZER: Varies,refer to PV Link Installation Manual MAXIMUM RECOMMENDED DC POWER FROM PV6: 10 kW(10),15 kW(30) 430 inverters offer islanding for 10 loads. 'Includes ambient temperature rising from inverter operation.Reduced power at extreme temperatures. Specifications listed in this document are achieved with firmware version 13310 or greater.Confirm inverter has latest firmware to ensure full performance. 6Values provided for PV-only or small storage systems.Additional PV power is permissible if sufficient battery storag: cc:paci s;ns,c'lec Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 www.Generac.com I 888-GENERAL(436-3722) GENERAC ® A0000528185 REV F ©2020 Generac Power Systems.All rights reserved. Specifications are subject to change without notice. GEN E RRAC PWRIED GENERAC° pwRICIMID The PWRcelf"Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need,small or large. No other smart battery offers the power C US and flexibility of PWRcell. Whether for backup power or smart `"�O energy management, PWRcell has power and capacity options Intertek for every need, without sacrificing flexibility or function. PWRceII BATTERY CABINET DESIGN FEATURES & BENEFITS Tne PWRcell Battery Cabinet allows system owners • Connect 2 PWRcell Battery Cabinets to a single PWRcell the flexibility to scale from an economical 8.6kWh to a Inverter for up to 36kWh of storage massive 18kWh by installing additional battery modules • Best-in-class battery backup power to the PWRcell Battery Cabinet.When needs change,an existing PWRcell Battery Cabinet can be upgraded with • Plug-and-play with PWRcell Inverter and PV Link'' additional modules. Use the graphic below and the chart • Time-of-use(TOU) and zero-export ready on the back of this sheet to understand what components • Residential and commercial application ready. you need for your chosen PWRcell configuration. • Outdoor-rated battery cabinet available as an upgrade BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY _.\, , $ il_6 � ac PWRIERi IIKVinab / 0 M6 M5 M4 M3 �' \/ PWRceII 6x Battery Module 5x Battery Module 4x Battery Module 3x Battery Module / \ —j Battery Cabinet *Module Spacer Kit *Module Spacer Kit j LLB 4 PWRcell -_ -- ---Battery Battery Cabinet Module Module Back Panel PWRcell Spacer Kit x5 Battery Cabinet xt Front Panel ,, Specifications ..,......,....,,.,...,...,.,,,...,,.,,......,,..,....,,,,,,.,.,...,..,...,,.,.......,................,..,....,......,...,,,...,..,,,. PWRcell BATTERY CONFIGURATIONS BATTERY MODULE SERIES: EX DCB BATTERY MODULES: 3 4 5 6 3 4 5 6 USABLE ENERGY: 9 kWh 12 kWh 15 kWh 18 kWh 8.6 kWh 11.4 kWh 14.3 kWh 17.1 kWh AVG.AC POWER OVER 3.4 kW 4.5 kW 5.6 kW 6.7 kW 3.4 kW 4.5 kW 5.6 kW 6.7 kW COMPLETE DISCHARGE CYCLE: MAX.CONT.AC POWER @ 40°C(104°F): 4.5 kW 6 kW 7.5 kW 9 kW 4.5 kW 6 kW 7.5 kW 9 kW PEAK MOTOR STARTING 25 33 42 50 25 33 42 50 CURRENT(2 SEC)-A,RMS REbus"VOLTAGE- INPUT/OUTPUT: 360-420 VDC NOMINAL VOLTAGE: 43.2 VDC 46.8 VDC DC-DC ROUND-TRIP EFFICIENCY: 96.5% MAX.AMBIENT OPERATING 14 to 122°F 41 to 113°F TEMPERATURE RANGE: (-10 to 50°C) (5 to 45°C) RECOMMENDED AMBIENT OPERATING 32 to 104°F 55 to 86°F TEMPERATURE(FULL POWER)': (0 to 40°C) (13 to 30°C) MAXIMUM INSTALLATION 9834 ALTITUDE-FT(M): (3000) DIMENSIONS, 22"x 10"x 68" LxWxH-IN(MM): (559x254x1727) WEIGHT,ENCLOSURE-LB(KG): 111(50) WEIGHT,INSTALLED-LB(KG): 282(128) 340(154) 397(180) 454(206) 276(125) 331(150) 386(175) 441(200) WARRANTY-LI-ION MODULES: 10 Years,(7.56MWh) WARRANTY-ELECTRONICS 10 Years AND ENCLOSURE: COMMUNICATION PROTOCOL: REbus'DC Nanogrid"' COMPLIANCE: UL 9540,UL 1973,UL 1642,CSA 22.2#107.1 'Performance may be limited outside of recommended operating temperature range PWRcell ACCESSORIES PWRcell MODEL BUILDER The PWRcell Battery Cabinet(APKE00007)is rated for indoor PRODUCT SERIES ENCLOSURE TYPE #OF MODULES use only.If installing outdoors,the PWRcell Outdoor Rated Battery Cabinet(APKE00028)must be used.Inside of the PWRcell IR r-'3 EX PWRcell Battery Cabinet,battery modules are stacked two deep 4, y 4, on three levels,allowing for up to six modules to be connected in series.You can upgrade an existing PWRcell Battery Cabinet by IR+. ,:>r Rated) 3 DCB OR(Outdoor Rated) 4 Modu, EX adding Battery Modules and a Module Spacer(APKE00008). 5 Moduls A Module Spacer is only required for battery configurations 6 Moduk with an odd number of modules(i.e.3 or 5). Sample Model Name:PWRcell IR M3 EX Generac offers a convenient PWRcell Battery Upgrade Kit (APKE00009)to help replace lost or misplaced hardware. Note:When adding modules,be sure all modules within an individual cabinet are of the some series type(Le.EX or DCB). Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 www.Generac.com 1888-GENERAL(436-3722) C E N E RAC® A0000528139 REV F ©2020 Generac Power Systems.All rights reserved. Specifications are subject to change without notice. GENERA pwR® 111 GENERAC� PWRIESD AUTOMATIC TRANSFER SWITCH em Gus Intertek _-_1 An integraged solar+storage system with load management for whole home coverage is made easy with the PWRcell`" Automatic Transfer Switch (ATS). Power the entire home and manage up to four individual HVAC (24 Vac controlled) loads with the PWRcell ATS.This built-in capability requires no additional hardware.When used in tandem with Generac Smart Management Modules(SMM) up to eight additional circuits can be controlled by the PWRcell Inverter. Make the most of your Generac solar+storage system with this comprehensive load management solution. FEATURES & BENEFITS • unlock whole home backup power capability for PWRcell solar+ storage systems • Manage up to four HVAC systems, and an additional eight circuits with optional Smart Management Modules(SMMs) • Aluminum type 3R enclosure with durable finish for indoor or outdoor installation • Heavy Duty Generac Contactor is an ETL recognized device, designed for years of service and reliability ,, Specifications ...,...,,,,.,.,.,....,......,...,.,.,,................,..,,.,.....,,..,.,.,.,,...............,..,..,...,..,...,.,.,....,.,..,,.....,. SPECIFICATIONS CXSC100A3 CXSW100A3 CXSW200A3 AMPS: 100 ;00 200 VOLTAGE 120/24010 120/24010 120/24010 LOAD TRANSITION TYPE(AUTOMATIC) OPEN TRANSITION OPEN TRANSITION SERVICE RATED OPEN TRANSITION SERVICE RATED ENCLOSURE TYPE NEMA 3R NEMA 3R NEMA 3R COMPLIANCE UL 1008 UL 1008 UL 1008 WITHSTAND RATING(AMPS) 10,000 10,000 20,000 LUG RANGE 1/0-#14 1/0-#14 250 MCM-#6 DIMENSIONS CXSC100A3 CXSW100A3 CXSW200A3 H1 17.24/437.9 17.24i437.9 26.75/679.4 HEIGHT(IN/MM) H2 20/508 20/508 30/762 W1 12.5/317.5 12.5/317.5 10.5/266.7 WIDTH(IN/MM) W2 14.6/370.8 14.6/370.8 13.5/342.9 DEPTH(IN/MM) 7.09/180.1 7.09/180.1 6.3/160.1 WEIGHT(LBS/KG) 20/9.07 22.5/10.21 39/17.69 Wi 1 1 i 1 I H2 H1 DEPTH —+ W2 -I Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 www.GeA00009 5134 REVcom 888-GENERAC(436-3722) GENERAC o A0000915134 REV A ©2020 Generac Power Systems.All rights reserved. — ..00.....111111111111111111111111111 Specifications are subject to change without notice. • • • �• rrrr • GENERAC PV Link .'S(i;' Eib 0 GENERAC' I # PV LinkTM C uS PV Link is the simple solar optimizer for quick installation Intertek and long-lasting performance. Connect PV modules to each PV Link to overcome shading and challenging roof lines. FEATURES & BENEFITS • Fast, simple installation • Lower failure risk than module-level optimizers • 2017/2020 NEC rapid shutdown compliant with SnapRS'" • Quick connections with MC4 connectors • Exports up to 2500W • Compatible with PWRcell`" Inverters • Cost-effective solution for high-performance PV • Ground-fa4,. protection SINGLE-STRING PV ARRAY WITH SnapRS DEVICES Where PV module-level rapid shutdown is required (NEC 690.12), a SnapRS device (RS) is installed to negative(-) lead of each PV module. — RS RS RS GENERA- PWy� — _ RS I:1 RS 1 � RS RS RS PV Link • PWRceII Inverter Diagram is applicable for most 60 cell PV modules.Modules with higher cell count may require a different arrangement. Contact Generoc for more details. „ Specifications ,.,......,......,.,.,.....,,........,..,...............,..,,.,,.,.......,,...,.,.,...,,,,....,...,.,,....,.,,...,....,..,.,,,,....,.. PV Link (APKE00010) RATED POWER': 2500W PEAK EFFICIENCY: 99% MPPT VOLTAGE RANGE: 60-360 VMP MAX INPUT VOLTAGE: 420 VOC;max when cold MAX OUTPUT: 420 VOC NOMINAL OUTPUT(REbus'"): 380 VDC MAX OUTPUT CURRENT(CONTINUOUS): 8 A MAX OUTPUT CURRENT(FAULT): 10 A MAX INPUT CURRENT(CONTINUOUS): 13 A @ 50°C,10 A @ 70°C MAX INPUT SHORT CIRCUIT CURRENT(ISC): 18 A STANDBY POWER: <1 W PROTECTIONS: Ground-fault,Arc-fault(Arc-fault Type 1 AFCI,Integrated).PVRSE MAX OPERATING TEMP:FAHRENHEIT(CELSIUS) 158°F(70°C) SYSTEM MONITORING: PWRview”Web Portal and Mobile App ENCLOSURE: Type 4X WEIGHT-LB(KG): 7.3 lb(3.3 kg) DIMENSIONS,LxWxH-IN(MM): 15.4"x 2"x 9.6"(391.2 x 50.8 x 243.8) COMPLIANCE: UL 1741,CSA 22.2 WARRANTY: 25 Years "PV Link can tolerate higher than rated power at its input if Max Input Voltage and Short Circuit Current specifications ore"at ex Cc- h b., Ili 11, • , 11/// r Vu 6,a Generac Power Systems,Inc. S45 W29290 Hwy.59,Waukesha,WI 53189 nerac.com 1888 GENERAL(436-3722) A0000528162 GENERAC ® REV D ©2020 Generac Power Systems.All rights reserved. Specifications are subject to change without notice. Shapiro Spring St,Q.Cell 360 ZIA IRONRIDGE 28357 INDUSTRIAL BLVD..HAYWARD,CA 94545 Project Details Name Shapiro Spring St(Q.Cell 360 Date 07/14/2022 Location 206 Spring Street, Northampton, MA 01062 Total modules 38 Module Custom Panels: QC360-v2 Total watts 13,680 Dimensions Dimensions: 67.6" x 41.14" x 1.26" (1717.0mm x 1045.0mm x 32.0mm) Attachments 70 ASCfi 7-10 Rails per row 2 System Weight Load Assumptions Total system weight 1,906.4 lbs Wind exposure B Weight/attachment 27.2 lbs Wind speed 117 mph Racking weight 239.4 lbs Ground snow load 40 psf Distributed weight 2.6 psf Attachment spacing portrait 4.0' Root Information Roof Material Family Metal Roof material Other Building height 20 ft Roof attachment L-Foot Only Roof slope 22 ° Attachment hardware Square Risk category II Span Detail XR10 - Portrait Reaction Forces XR100 - Portrait Zone Down Uplift Lateral Zone Max span Max cantilever (Ws) (lbs) (lbs) 1 11" 2' 9" 1 265 106 94 6' 11" 2' 9" 265 218 94 3 6' 11" 2' 9" 265 344 94 Roof Section 1 Details Weights Panels: 38 Provided rail: 288' [12 x 204", 6 x 168"] Total weight: 1,904.0 lbs Rail orientation: East-West Attachments: 70 Weight/attachment: 27.2 lbs panel orientation: Portrait Splices: 10 Total Area: 745.0 sq ft Entry type: Graphical Clamps: 84 Distributed weight: 2.6 psf (D Last updated by Stefan Maier on 05/03/22 03:19 PM Page 1 of 5 Shapiro Spring St(Q.Cell 360 Iff94553W "I�IRONRIDGE -.. 37 INDUSTRIAL BLVD..HAYWARD.CA 94545 • Diagram /3 cO/ tiS rr 0- ..111 ., tiq l u w Segments Identifier Columns Row Rail Cantilever Cantilever Rail Attacnments Splices Clamps length length Violations A 9 31' 3" 31' 3" 1' 8" None 68' [4 x 2041 2. B 3 10' 6" 10' 6" 1' 3" None 28' [2 x 168") 6 0 8 C 13 45' 1" 45' 1" 7" None 96' [2 x 168", 4 24 4 28 x2041 Row segment totals (x 2) -, 192' [4 x 168", 48 8 56 8x2041 Contour Plan -Trim Cut List Identifier Scrap from Length Scraps Created Discard C) Last updated by Stefan Maier on 05/03/22 03:19 PM Page 2 of 5 Shapiro Spring St(Q.Cell 360 IRONRIDGE ... 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Diagram • I , Segments Identifier Columns Row Rail Cantilever Cantilever Rail Attachments Splices Clamps length length Violations A 9 31' 3" 31' 3" 1' 8" None 68' [4 x 2041 16 2 20 B 3 10' 6" 10' 6" 1' 3" None 28' [2 x 1681 6 0 8 C 13 45' 1" 45' 1" 7" None 96' [2 x 168", 4 24 4 28 x 204"] Row segment totals (x 2) - 192' [4 x 168", 48 8 56 8 x 2041 Contour Plan -Trim Cut List Identifier Scrap from Length Scraps Created Discard 0 Last updated by Stefan Maier on 05/03/22 03:19 PM Page 2 of 5 Shapiro Spring St(Q.Cell 360 IRONRIDGE 2335'INDUSTRIAL BLVD.,HAYWARD,CA 94545 Splice Details 1 TOP-FACING SLOT / XR100 RAIL INTERNAL SPLICE r _ I BONDING SPRING ill IXR100 INTERNAL SPLICE j I SIDE-FACING SLOT Splice Connection XR100 Clamp Detail PV MODULE UNIVERSAL RAIL STOPPER FRAME FASTENING \ /, SLEEVE hboilliplopp __ 08JECT PV MODULE /// \ UNIVERSAL -----UNIVERSAL FRAME ` FASTENING FASTENOBJECTING PV 1111111 I� FRAME MODULE � % UNIVERSAL OBJECT _ 7 / FASTENING III OBIECT r RAIL RAIL STOPPER PV MODULE SLEEVE FRAME Mid Clamp,Plan Mid Clamp,Front End Clamp,Plan End Clamp,Front Last updated by Stefan Maier on 05/03/22 03:19 PM Page 3 of 5 Shapiro Spring St!"Q.CeII 360 /lam IRONRIDGE 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Splice Details TOP-FACING SLOT I 1//^ ! / XR100 RAIL 1 INTERNAL SPLICE BONDING SPRING I r l ill r L ,`_� l FXR100INTERNAL SPLICE Splice Connection �I — --SIDE-FACING SLOT XR100 Clamp Detail FA TET 1" RAIL .-- -STOPPER SLEEVE __ PV MODULE UNIVERSAL/� —� FRAME FASTENINGUNIVER ALPVMODULE j J S FRAME UNIVERSAL _r FASTENING PV MODULE 1 FASTENING OBJECT I FRAME I % UNIVERSAL FASTENING rt____Th C - RAIL OBJECT \ j -/ RAIL I STOPPER \___,PV MODULE SLEEVE FRAME Mid Clamp, Plan Mid Clamp,Front End Clamp,Plan End Clamp,Front 0 Last updated by Stefan Maier on 05/03/22 03:19 PM Page 3 of 5 Shapiro Spring St(Q.Cell 360(e94ss38) /, .IRONRIDGE ! ., 28357 INDUSTRIAL BLVD_HAYWARD,CA 94545 Grounding Diagram • I 1°1 i,,,-,..,,, __ I ._ I - i CO< s I : ! .0... >,\SiiiE L) 77 0 .mo< („0,_ _ __ • _ _,;_,,,----„,,, i i°1 i 1 I i 1 i i MO? 0 i---- c0 OUFO Clamp ® Grounding Lug * -3 Fault Current Ground Path Min 10 AWG Copper Wire * Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last updated by Stefan Maier on 05/03/22 03:19 PM Pacc 4 of 5 Shapiro Spring St(Q.Cell 360 IRONRIDGE .. 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 'Grounding Diagram rAc—r—m---7.-7T-F----);\-\\g 0) r: ` , - -LIJ - -� V 0 - _O v v — —I-,-I — —/ \ V O 0 (-,----\-- 6--:-,. 1-7-7 (--,:\-- -,---- 0 I -O r, Jr-, - -1-1-1 - - ,� ,� • I , i OUFO Clamp • Grounding Lug * — Fault Current Ground Path _L Min 10 AWG Copper Wire * Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. /;f- ( ,_c' et id 6 "//ry, /7-r/14^- P -- 7 RUA/k- 474 TV2: ( vi/,6,F.(5 ko,, je„j A -- R,,,tjii,, e 6e„I 6,4,,/( ;4 .0 i iit o--1/ v1/47/1-\ 141,, NI, h6) , ,/, ,i) _7 (i a , L-70/2 r21,4--94- , , 1 , , „,,,,,,4,1 c„.,_ Rocly- 0(' 64 Okt04--,/ yir ,,, Hi&(-vid IN--ii\k_ fr' i4- , vv, ,, , i r i' da...\- u 0 Last updated by Stefan Maier on 05/03/22 03:19 PM Page 4 of 5 Shapiro Spring St(Q.Cell 360 t IRONRIDGE 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Bill of Materials Part Spares Total Qty Rails& Splices XR-100-204B XR100,Rail 204"(17 Feet)Black 0 12 XR-100-168B 0 6 XR100,Rail 168"(14 Feet)Black XR100-BOSS-01-M1 Bonded Splice,XR100 0 10 Clamps & Grounding UFO-CL-01-B1 Universal Module Clamp,Black 6 90 UFO-STP-32MM-B 1 Stopper Sleeve,32MM,Black 4 20 XR-LUG-03-A1 0 4 Grounding Lug,Low Profile Attachments LFT-03-B1 Slotted L-Foot,Black 8 78 BHW-SQ-02-A1 8 78 Square-Bolt Bonding Hardware Accessories XR-100-CAP 0 1 Kit,End Cap XR100(10 sets per bag) BHW-MI-01-A1 -20 18 Microinverter/MLPE Bonding Hardware,T-Bolt 0 Last updated by Stefan Maier on 05/03/22 03:19 PM Page 5 of 5 '%i •wvini-orM 4 . a :' t-,•]•43:: , - i:,,,,' '','"!-. ,-: ', Clet,iiit:ii AlorKI AO g erforatiolvsi P I PROFESSIONAL L T '� ELECTRICIANS S LJ S THEL 'WING 'LICENSE ii. :), �NEV. fillAN ELECTRICIAN '" '..s.L r - by dk T ' &i,.te ° "; E;:; ;i:k.,k�.:S `v ,� g:,,'ate" .. -" U .. .. ... '-"r'.'<--e'>, ,, \• �' �t`�3 'mays ".{ y REVISION HISTORY Ir REV druDESMeg SMSPilON 12/1120 I APPROVED original 2 revision(MTS to ATS) 2/1621 SMS 3 Added low voltage(CATS) 7/1422 SMS and CTs. Updated Module information. 13.7 kW DC array root mounted on Main Building ' S MART meta socket —.� — ,— _ Label:Utility 1; production meta _ _ Rapid Shutdown button(nlc) with 100A tla Pale 2A DC (NEC 2017 compatible) breaker under secrete U huts ort both PV stray and cover. Energy storage system. i� Grid e r C • 18 111 28 DC. n 1234NlRSD • nc n 0W q/4t 4/4I 1C DC ~2C -4 4 4 9 4 existing NG service _ 1 (240V 200A 1P H) 1 components located on west wall of main dweihn3 with 200A main breaker 1 service entrance /10 PV wire(1000V) — DC wiring box J - Customers (Wiley box) Internet router CTs Installed upstream of taps Inside transfer switch. j Wire to CT terminals inside I transfer winch. #8 THWN+red-blue - -I - + Pant of Interconnection Use 1'EMT bath inside and Q Generac PW Rcell Battery € switch de tap Inside transfer outside of building.J I I I HIIIIF I i 1200A -.. ==�__� ATS ' 2CrTA I E -1—_ - b ,, I I r= 1za1 DC Disconnects(integrated in inverter) I I �`(y. III I J __— Ar_.1 En.;1 '.," f AC2 31. EE Generac PWRce11 x7602 inverter Ma,n panel 240VAC 7.6kWAC -- wbttin ATS components located in basement of Main Building COLOR CODE ` black:previously existing components green:new to be installed components CUSTOMER: alignment pcs Make/Model Riling Comment + µ ,,,,,¢dT.)y grrd-ned a, Logan Shapiro Inverter 1 Generac PWRcelI x7602 7.6kWAC;240VAC;32A;1 PH; UL 1741 SA;IEEE 1547(Rule 21&14H) NG acatl':90695-54033 grid-independent Meters:52501356 PV Module 38 Q-Peak Duo BLK-Gl 0+ STC:Max Power 360W,Voc 41.18V;lsc 11.04A 5 strings of 8 modules residential Rapid shut down 40 Generac SnapRS Snap-RS802 Module level shut down on roof •SYSTEMS — Kau power Storage battery 1 Generac PWRcell battery Useabel Energy 1 7.1 kWH;Nominal cont.power Storage configuration:Charging:Generation only/ subnted by: SUM ADORES& 6.7kW;nominal use energy hours:2.5hrs;annual Discharging:Unrestricted to onsite loads and grid Stefan Maier-Domestic DC systems 206 Spring St Discharge requirement 593 kWh/yr 166 Chestnut Hill Rd.-ORANGE,MA 01364 Florence,MA 01062 PHONE'. 978-424-5659 Automatic transfer 1 Generac CXSW200A3 200A,120/240V,1 phase Open transition service rated,NEMA 3R enclosure EMAIL: efan@danesficDCsysterrs.com switch Safety Insurance BUSINESSOWNERS DECLARATIONS ,: Fr AUTO • HOME • BUSINESS Policy Period Safety InsuranceCompany Policy Number To. . BM.A0016234 09/07/2021 09/07/2022 f , Z 2 01 A 4r1rdeud T z:>.wt tte les-f tbed toss*o{z Transaction ' s * Renewal Declarations 4 t Named Insured and Mailing Address Agent I RICHARD J GALLO HERB LEWIS INS AGCY 113 LONG PLAIN ROAD 19 WEST ST LEVERETT MA 01054 WALPOLE MA 02081 I 1 .,-,' Telephone: 508-668-2270 30429 Form of Business: INDIVIDUAL INDIVITUAL Type of Business: ELECTRICAL WORK ' ._B . BLDG DESCRIBED PREMISES LOC BLDG ADDRESS AUTOMATIC INCREASE f 113 L CNL,.' az rr,C ROAD L'l. TERE 'T MAj1ti iL. 444 -rx 2' PROPERTY LOC BLDG COVERAGE VALUATION DEDUCTIBLE LIMIT OF INSURANCE CCi r;31 Personal P cp rty Replacement. Cost 500 4,"796 Deductible shown above applies per any one occurrence BUSINESS INCOME: Actual Loss Sustained Not Exceeding 12 Consecutive Months LIABILITY AND MEDICAL EXPENSES Except for Fire Legal Liability, each paid claim for the coverages listed reduces the amount of insurance we provide during the applicable annual period, Please refer to Paragraph D.4, of the Businessowners Liability o -:tage Form, BUSINESS LIABILITY COVERAGE LIMITS OF INSURANCE Liability 1 , 000 r 000 Per Occurrence Medical Expenses $ 1 0 , 000 Per Person Fire Legal Liability 0 , 000 Any one Fire/Explosion ADDITIONAL COVERAGES ;roe prop,rty co,,,,ferages are subject to deductibles s«ecified in the policy forms, Ontio l Prr nn t r ('rIu ►r ut r r.rirxtlr:r, r I unite of Inc ,r a-tr ,.