Northampton bridge ElectricalEXISTING RAIL-TRAIL BRIDGERAILROAD BRIDGE #1RAILROAD BRIDGE #2RAILROAD BRIDGE #3ROADWAY BELOWSIDEWALKBELOWSIDEWALKBELOWWEATHERHEADPARKING TICKET MACHINEBIKE RENTALPOWER CABINETPARKING TICKET MACHINEOH LINE RUN BELOWBRIDGE TO FEEDWEATHERHEADOH LINE RUN BELOWBRIDGE TO FEEDWEATHERHEADSWEATHERHEADWEATHERHEADDEMOLITION SPECIFIC NOTES1.REMOVE EXISTING LIGHT FIXTURE, OUTLET AND ALL CONDUIT AND WIRING FROM SAMEBACK TO SOURCE.2.DISCONNECT CIRCUIT FEEDING RAIL TRAIL LIGHTING. RE-SPLICE CONDUCTORS ASREQUIRED AND PROVIDE A KNOCK OUT SEAL ON THE BASE OF THE LIGHT POLE AND MAKEWATERTIGHT.3.REMOVE PHOTOCELL AND ALL CONDUIT AND WIRE FROM SAME BACK TO SOURCE.4.CONTACT UTILITY COMPANY TO HAVE OVERHEAD DROPS TO THE BRIDGE FROM THEUTILITY POLES DISCONNECTED AND REMOVED.5.REMOVE HID FIXTURE AND ALL WIRING FROM SAME BACK TO SOURCE.NOTES1.RAIL TRAIL BRIDGE IS PHASE 1 WORK. NEWELECTRICAL SERVICE AND CLIMATE CONTROLLEDENCLOSURE AND ALL CONTROLS AND EQUIPMENT INTHE CABINET ARE PHASE 1 WORK.2.BRIDGES 1, 2 AND 3 ARE PHASE 2 WORK.P3CATALOG NUMBERCOLORKINETICSMANUFP1NOTYPENOLAMPSXREMARKSSURFMOUNTINGRECPENDXVOLT33LOADLIGHTING FIXTURE SCHEDULEXP2--423-000004-24, 120-000189-13,120-000189-29,106-000011-30,106-000004-00RGBW 8° BLK, 40°LENS,GLARESHIELD, UL BOXRGBW1293 LUMENSRGBW993 LUMENS28.54' RGBW LED WETLOCATION BLKLOUVER/BAFFLE423-000001-17, 120-000202-03,108-000055-00,, 108-000057-12,106-000004-004 #101-000077-04, 4 #999-000082-XXX,2 #109-000034-00, 2 # 309-000014-01,19 #101-000057-01 BLK,5 #101-000061-00,----RGB575 LUMENSSYMBOL SCHEDULEWALLFL'RCEILDESCRIPTION1.PROVIDE THE FOLLOWING CONTROL EQUIPMENT IN THE CLIMATE CONTROLLED EQUIPMENT CABINET: 2 # 120-000084-01, 8 PORT POE SWITCHES;1 #103-000029-01 LANDMARK GATEWAY; 2 #103-000202-00 PHAROS LPC4.2.ALL LIGHTING AND CONTROLS SHALL BE INSTALLED IN COMPLIANCE WITH ALL MANUFACTURES INSTALLATION INSTRUCTIONS AND SHALLINCLUDE START UP AND COMMISSIONING BY THE LIGHTING MANUFACTURE.70' RGB LED WETLOCATION WITHMOUNTING TRACKAND DOMEFIXTURESLOWVOLT-AGE12Consulting Engineers, Inc.ROBT W. HALLTEL. (413) 789-0960AGAWAM, MA 01001MEADOW STREET EXT.001-6524-21SCALE: AS NOTEDJOB NO.DWG. NO.FAX (413) 789-3295DRAWN BY:CHECKED BY:DATE: 2-24-22DOWNTOWN BRIDGE LIGHTINGCITY OF NORTHAMPTON23 MAIN ST, NORTHAMPTON, MA 01060MLBPBELECTRICAL DEMOLITION PLANSCALE: 1/8"=1'-0"E.1ELECTRICAL DEMOLITION PLAN ANDSCHEDULES
EXISTING RAIL-TRAIL BRIDGERAILROAD BRIDGE #1RAILROAD BRIDGE #2RAILROAD BRIDGE #3ROADWAY BELOWSIDEWALKBELOWSIDEWALKBELOWP1-6P2-8P2-8P2-8P2-4P2-4P1-2P3-10P3-10P3-12P3-1212.14 FTSPECIFIC NOTES1.PROVIDE UNISTRUT TO LOWER FIXTURE SO IT IS EQUAL TO LOWEST STRUCTURE AROUNDTHE FIXTURE.2.PROVIDE A 1.25" CONDUIT SLEEVE AND RUN COLOR KINETICS JUMPER CABLE THRUCONDUIT FOR PROTECTION. PROVIDE INSULATED BUSHING ON THE END OF ALL CONDUITSAND MOUNT THE CONDUIT ON A SLIGHT FOR WATER RUN OFF.3.PROVIDE A 1.25" CONDUIT SLEEVE AND RUN COLOR KINETICS LEADER CABLE THRUCONDUIT.4.PROVIDE A MINIMUM OF A 2-GANG CAST BOX WITH WEATHERPROOF COVER WITH TAMPERPROOF SCREWS AND SPLICE THE LEADER CABLE AND CONDUCTORS RUN TO THEJUNCTION BOX.5.NOT USED6.PROVIDE DATA ENABLER PRO FOR P1 FIXTURES. MOUNT IN TOP OF TRESTLE AT ANACCESSIBLE LOCATION. PROVIDE 1/2"C- ONE CAT6 CABLE TO NETWORK SWITCH INCONTROL PANEL.7.PROVIDE DATA ENABLER PRO FOR P2 FIXTURES. MOUNT ON TOP OF TRESTLE AT ANACCESSIBLE LOCATION. PROVIDE 1/2"C- ONE CAT6 CABLE TO NETWORK SWITCH INCONTROL PANEL.8.PROVIDE 1.5"C WITH SINGLE MAXCELL INNERDUCT WITH LEADER CABLE FROM FIXTURE TOCONTROL CABINET AT BIKE PATH. ORDER LENGTH AS REQUIRED. SPECIAL ORDERLENGTHS WILL BE REQUIRED. THE CONTRACTOR MAY RUN A MAXIMUM OF 2 CABLES IN ASINGLE CONDUIT FROM THE SAME LINEAR RUN OF FIXTURE. PROVIDE JUNCTION BOXES,ETC REQUIRED.9.PROVIDE A 1.25" CONDUIT SLEEVE AND RUN EXTRA HARD USE WEATHERPROOF TYPESOOW CABLE WITH KELLEMS GRIP THRU CONDUIT CABLE WITH 3 # 12 + 1 # 12 GROUNDSHIELDED CABLE WITH SOLID CONDUCTORS. SEE MOUNTING DETAILPARKING TICKET MACHINEBIKE RENTALPOWER CABINETPARKING TICKET MACHINEP-1,3P-1P-3WPP-5P-2,4P1-2P1-2P1-2P1-2P1-2P1-2P2-4P1-6P1-6P1-6P1-6P1-6P1-6P1-6,8NOTES1.THE CONTRACTOR SHALL PROVIDE A UNISTRUT MOUNTING RACK BOLTED TO THECONCRETE PAD TO MOUNT THE CLIMATE CONTROLLED BOX AND PAD MOUNTEDENCLOSURE FOR LIGHTING CONTROL EQUIPMENT.2.THE E.C. SHALL PROVIDE UNISTRUT CHANNELS TO MOUNT ALL LIGHT FIXTURES ON METALBRIDGE UNDERSIDE AND WOOD BLOCKING AS INDICATED BELOW.3.THE TYPE P1 FIXTURE SHALL BE MOUNTED UP IN BETWEEN THE BEAM POCKETS. ALLWIRING SHALL BE RUN AS HIGH AS POSSIBLE ON THE STRUCTURE NOT ON THE UNDERSIDEOF THE BEAMS UNLESS ABSOLUTELY NECESSARY .4.THE TYPE P2 FIXTURE SHALL BE RUN ON THE UNDERSIDE OF THE STRUCTURE. PROVIDEALL UNISTRUT REQUIRED.5.THE TYPE P3 FIXTURES SHALL BE RUN IN BETWEEN THE WOOD JOISTS. THE CONTRACTORSHALL PROVIDE WOOD BLOCKING ON MOUNTING CENTERS REQUIRED TO MOUNT THE 4'SECTIONS OF TRACK THE FIXTURES MOUNT TO. THE BLOCKING SHALL BE HIGH ENOUGHTO ALLOW A CONTINUOUS RUN OF FIXTURE LENGTH SHOWN ON THE DWGS.6.ALL PARALLEL CONDUIT RUNS TO BRIDGES 1 AND 2 SHALL BE RUN UP IN THE POCKETS OFTHE BEAMS.7.ALL CONDUITS SHALL BE RGS.8.CONDUITS THAT SPAN BETWEEN BRIDGES 2 AND 3 SHALL BE ATTACHED TO THEUNDERSIDE OF THE STRUCTURE AND HAVE A MINIMUM OF TWO (2) PIPE STRAPS AT EACHBRIDGE WITH VIBRATION MATERIAL INSTALLED BETWEEN THE CONDUIT AND THESTRUCTURE. THE CONDUITS SHALL HAVE INSULATED BUSHING ON EACH END OF THECONDUITS.9.PROVIDE nVENT #A60R3618FSLP PAD MOUNT TYPE 3R ENCLOSURE TO MOUNT PANEL P IN.THE SELF-CONTAINED METER SOCKET SHALL BE INSTALLED TO THE SIDE OF THEENCLOSURE. ALL PENETRATIONS TO THE ENCLOSURE SHALL BE WATERTIGHT.NEW PANEL P IN WPENCLOSURENEW 200A,120/208V-3ɸ-4W WPMETER SOCKETEXISTING UTILITYCOMPANY 30-1 POLENEW UNDERGROUNDFEEDER. PROVIDE 4"C- 4 #3/0 + 1 # 4 GROUNDRUN CONDUIT UP POLEA MINIMUM OF 10'NEW PANEL P IN WPENCLOSURELIGHTING CONTROL WPEQUIPMENT ENCLOSURENEW COOLING AND HEATINGCABINET IN NEMA 3R ENCLOSURETO PROVIDE CLIMATE CONTROL INEQUIPMENT ENCLOSURENEW 200A,120/208V-3ɸ-4W WPMETER SOCKETConsulting Engineers, Inc.ROBT W. HALLTEL. (413) 789-0960AGAWAM, MA 01001MEADOW STREET EXT.001-6524-21SCALE: AS NOTEDJOB NO.DWG. NO.FAX (413) 789-3295DRAWN BY:CHECKED BY:DATE: 2-24-22DOWNTOWN BRIDGE LIGHTINGCITY OF NORTHAMPTON23 MAIN ST, NORTHAMPTON, MA 01060MLBPBELECTRICAL LIGHTING PLANSCALE: 1/8"=1'-0"ELECTRICAL SERVICE EQUIPMENT ANDLIGHTING PLANSCALE: 1/8"=1'-0"E.2ELECTRICAL LIGHTING PLAN
PHAROS LPCPoE NETWORKSWITCHCONDITIONED/WEATHERPROOFENCLOSURE(BY E.C.)100-240VAC INMOLDED CORD ACAPLANDMARK GATEWAY100-240VAC INMOLDED CORD CAPTO LOCAL AREANETWORKTYPE P24' GRAZE MX4 POWERCORETYPE P24' GRAZE MX4 POWERCORETYPE P24' GRAZE MX4 POWERCOREDATAENABLERPRO #1GRAZE LEADERCABLEFEED:120V/277AC2W + GND 20A(MAX)WPJBOXBRANCH WIRING:#12 SOLID, 3W + GNDFLEX LMXLEADER CABLESPART# 309-000014-01POWER SUPPLY, 320WLINEVOLTAGE IN3 WIRE POWERCABLE (BY E.C.)REFER TO PRODUCTGUIDE FOR WIRE DETAILSPOWER CABLE(BY E.C.)OUT TO NEXTCM-150CA(AS REQUIRED)TYPE P3FLEX COMPACT GEN3 HECM-150CA 4 WIRESURFACE MOUNTDATAENABLERPROLAND ONDMX-INDATAENABLERPROLAND ONDMX-INFLEX LMXLEADER CABLESTYPE P3FLEX COMPACT GEN3 HECM-150CA 4 WIRESURFACE MOUNTCAT5E/CAT6(BYE.C.)CAT5E/CAT6(BY E.C.)LAND ONDMX-INTYPE P24' GRAZE MX4 POWERCORETYPE P24' GRAZE MX4 POWERCORETYPE P24' GRAZE MX4 POWERCOREDATAENABLERPRO #1GRAZE LEADER CABLEFEED:120V/277AC2W + GND 20A(MAX)WPJBOXBRANCH WIRING:#12 SOLID, 3W + GNDLAND ONDMX-INFLEX LMXLEADER CABLESPART# 309-000014-01POWER SUPPLY, 320WLINEVOLTAGE IN3 WIRE POWERCABLE (BY OTHERS)REFER TO PRODUCTGUIDE FOR WIRE DETAILSOUT TO NEXTCM-150CA(AS REQUIRED)TYPE P3FLEX COMPACT GEN3 HECM-150CA 4 WIRESURFACE MOUNTFLEX LMXLEADER CABLESTYPE P3FLEX COMPACT GEN3 HECM-150CA 4 WIRESURFACE MOUNTCAT5E/CAT6(BY E.C.)CAT5E/CAT6(BY E.C.)CAT5E/CAT6(BY E.C.)BRANCH WIRING:#12 SOLID, 3W + GNDBRANCH WIRING:#12 SOLID, 3W + GNDCAT5E/CAT6(BY E.C.)GRAZE JUMPER CABLELENGTH TBDGRAZE JUMPER CABLELENGTH TBDGRAZE JUMPER CABLELENGTH TBDGRAZE JUMPER CABLELENGTH TBD120/277VAC2W + GND120/277VAC2W + GNDCAT5E/CAT6(BY E.C.)CAT5E/CAT6(BY E.C.)CAT5E/CAT6(BY E.C.)POWER CABLE(BY E.C.)NOTES1.THE CONTRACTOR SHALL CUT OFF CONNECTOR ON MANUFACTURERS LEADERCABLE AT THE CM-150-CA END TO BE ABLE TO RUN CABLE THRU CONDUIT. THECONTRACTOR SHALL REPLACE THE FEMALE CONNECTORS ON THE CM-150-CA WITHA NEW WEATHERPROOF GLAND FITTING AND RUN CABLE THRU GLAND ANDTERMINATE ON FOUR WIRE OUTPUT TERMINALS IN THE CM-150-CA.2.ALL CM-150-CA SHALL BE LOCATED IN THE CLIMATE CONTROLLED ENCLOSURE.3.THE E.C. SHALL PROVIDE A CLIMATE CONTROLLED ENCLOSURE. SEESPECIFICATIONS.4.THE E.C. SHALL PROVIDE TWO GFI RECEPTACLES IN THE ENCLOSURE ONEMOUNTED ADJACENT TO THE GATEWAY AND PHAROS EQUIPMENT., THE OTHERSHALL BE FOR SERVICING WITHIN THE CABINET.5.THE E.C. SHALL TERMINATE A SECOND SET OF POWER CABLES TO THE TERMINAL INTHE 1ST CM-150CA AND RUN TO THE NEXT CA-150CA. CONNECT A MAXIMUM OF TWOCM-150CA'S TO A SINGLE POWER SUPPLY. CABLE SHALL BE A MINIMUM OF A 2c#18RATED FOR WET LOCATION. THE CONTRACTOR SHALL DETERMINE SIZE OF CABLEBASED ON VOLTAGE DROP REQUIREMENTS.6.THE CONTRACTOR MAY RUN TWO LEADER CABLES FROM FIXTURES P3 IN THE SAMECONDUIT. CABLES SHALL BE FROM THE SAME LINEAR LENGTH OF THE P3 FIXTURE.TO NEXT CM-150CASEE NOTE 5TO NEXT CM-150CASEE NOTE 5TYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTTYPE P1COLORBURSTPOE SW.PHAROS LPCGATEWAYCONTROLLERCM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
320W POWER SUPPLY
COLOR KINETICS
#309-000014-01
320W POWER SUPPLY
COLOR KINETICS
#309-000014-01
320W POWER SUPPLY
COLOR KINETICS
#309-000014-01
320W POWER SUPPLY
COLOR KINETICS
#309-000014-01
JBJBCM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
CM-150-CA
COLOR KINETICS
#109-000034-00
P-10,16P-16JBJBP-12,14P-10P-10P-12P-12P-14CONDUITS FOR CAT6 CABLE FROM DATAENABLER PROCONDUITS FLEX LEADER CABLEFROM FIXTURES P3LEADER CABLES FROMFIXTURE P3 TYPICALMOUNTING BACKBOARDIN ENCLOSURECAT 6 CABLE TYPICALUP TO UPPERCM-150CA'S TYPICAL3"42"16"60"NOTES1.ALL WIRING FOR 120V EQUIPMENT AND DEVICES SHALL BE ACCOMPLISHED USINGCONDUIT AND WIRE WITH THE EXCEPTION OF THE LEADS FROM THE POWER SUPPLIESWHICH MAY BE RUN TO THE JUNCTION BOXES DIRECTLY. PROVIDE A WEATHERPROOFGLAND ON THE JUNCTION BOX FOR THE ENTRY INTO THE JUNCTION BOX.2.THE SEPERATE CLIMATE CONTROL CABINET SHALL BE MOUNTED TO THE RIGHT OR LEFTSIDE OF THE CABINET. CUT THE MANUFACTURERS RECOMMENTED OPENING BETWEENCABINETS. PROVIDE WEATHERTIGHT SEALS BETWEEN ENCLOSURES.3.THE TWO CABINETS SHALL BE NEMA 4 AND MANUFACTURED BY THE SAME EQUIPMENTMANUFACTURE TO ENSURE PROPER ATTACHMENTS BETWEEN CABINETS.4.THE GENERAL CONTRACTOR SHALL PROVIDE CONCRETE PAD FOR THE MOUNTING OFTHE CLIMATE CONTROL EQUIPMENT CABINET MOUNTED TO THE LEFT SIDE OF THEEQUIPMENT CABINET. THE NEW MAIN PANEL AND METER SOCKET SHALL BE MOUNTED ONTHE BACK SIDE OF THE EQUIPMENT ENCLOSURE. THE SIZE OF CONCRETE PAD SHALL BEA MINIMUM OF 12' X 5'. PAD SHALL BE MOUNTED ON A COMPACTED GRAVEL BASE.ALLEQUIPMENT BOLTED TO THE CONCRETE PAD SHALL HAVE A MINIMUM DISTANCE OF 8"FROM THE EDGE OF THE PAD. THE CONTRACTOR SHALL ENLARGE THE EQUIPMENTENCLOSURE AS REQUIRED.PHAROS LPCPOE SW.Consulting Engineers, Inc.ROBT W. HALLTEL. (413) 789-0960AGAWAM, MA 01001MEADOW STREET EXT.001-6524-21SCALE: AS NOTEDJOB NO.DWG. NO.FAX (413) 789-3295DRAWN BY:CHECKED BY:DATE: 2-24-22DOWNTOWN BRIDGE LIGHTINGCITY OF NORTHAMPTON23 MAIN ST, NORTHAMPTON, MA 01060MLBPBMANUFACTURES WIRING DIAGRAMNO SCALEEQUIPMENT CABINET DETAILNO SCALEE.3ELECTRICAL DETAILS AND WIRINGDIAGRAMS