38D-018 (12) BP-2022-1020
25 HAMPDEN ST COMMONWEALTH OF MASSACHUSETTS
Map:Block:Lot:
38D-018-001 CITY OF NORTHAMPTON
Permit: Solar Build
PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
BUILDING PERMIT
Permit# BP-2022-1020 PERMISSION IS HEREBY GRANTED TO:
Project# SOALR 2022 Contractor: License:
Est. Cost: 27000 SKYLINE SOLAR LLC CSL027047
Const.Class: Exp.Date: 11/09/2023
Use Group: Owner: B ROUNDS CALEB M&MARGARET
Lot Size (sq.ft.)
Zoning: URB Applicant: SKYLINE SOLAR LLC
Applicant Address Phone: Insurance:
95 RYAN DRIVE SUITE 3 (732)354-3111 BNUWC0156055
RAYNHAM, MA 02767
ISSUED ON:08/18/2022
TO PERFORM THE FOLLOWING WORK:
ROOF MOUNT SOLAR -21 PANELS/7.45KW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter: Footings:
Rough: Rough: House# Foundation:
Final: Final: Final: Rough Frame:
Gas: Fire Department Driveway Final: Fireplace/Chimney:
Rough: Oil: Insulation:
Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
14
Fees Paid: $75.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Office of the Building Commissioner
The Commonwealth of MassacLn0
etts
n Board of Building Regulations andnd ds A UG 1 F R
Massachusetts State Building Code, 0 R2022Building Pert Application To Construct,Repair918 a vise Mar 2011
One-or Two-FamilyDwelhrt " '�TF+.nM Pro rNSPFcr Ns
��'. ON
This Section For Official Use Only
Building Permit Numbers '" /0 Zd Date Applied:
4Z5S
818-20*
Building Official(Print Name) Signature Date
SECTION 1:SITE INFORMATION
1.1 Property Address:25 Hampden Street 1.2 A4ses Map&Parcel Numbers l
Northampton.MA 01060 �J
1.1a Is this an accepted street?yes x no Map Number Parcel Numhcr
1.3 Zoning Information: 1.4 Property Dimensions:
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public l� Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system 0
Check if yes❑
SECTION 2: PROPERTY OWNERSHIP'
2.1 Owner'of Record:
Caleb Rounds Northampton,MA 01060
Name(Print) City,State,ZIP
25 Hampden Street 413-559-1698 permits@skylinesolar.net
No.and Street Telephone Email Address
SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply)
New Construction❑ Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition ,❑
Demolition 0 Accessory Bldg. 0 Number of Units Other 13 Specify:Rooftop PV Solar System
Brief Description of Proposed Work2: Installation of a safe and code compliant,grid-tier PV solar system on an
existing residential roof.21 Panels/7.45kW.
SECTION 4: ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs: Official Use Only
(Labor and Materials)
1. Building $ 6000 1. Building Permit Fee:$ Indicate how fee is determinled:
2.Electrical $ 21000 ❑Standard City/Town Application Fee
❑Total Project Cost'(Item 6)x multiplier x
3. Plumbing $ 0 2. Other Fees: $
4. Mechanical (HVAC) $ 0 List:
5. Mechanical (Fire $ 0
Suppression) Total All Fees:
Check No. eck Amon)/6 Cash Amount:
6.Total Project Cost: $ 27,000 0 Paid in Full ❑Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL)
Phil Chouinard License Number Expiration Date
Name of CSL Holder
95 Ryan Dr,STE 3, List CSL Type(see below)
No.and Street Type Description
Raynham,MA 02767 U Unrestricted(Buildings up to 35,000 cu.ft.)
R Restricted 1&2 Family Dwelling
City/Town,State,ZIP M Masonry
RC Roofing Covering
WS Window and Siding
SF Solid Fuel Burning Appliances
732-354-3111 permits@skylinesolar.net I Insulation
Telephone Email address D Demolition
5.2 Registered Home Improvement Contractor(HIC)
172284 6/6/2024
172284 HIC Registration Number Expiration Date
HIC Company Name or HIC Registrant Name
Skyline Solar LLC permits@skylinesolar.net
No.and Street Email address
4 Crossroads Dr.STE 116 Hamilton,NJ 08691 732-354-3111
City/Town,State,ZIP Telephone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes l No .0
SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property, hereby authorize Skyline Solar LLC
to act on my behalf, in all matters relative to work authorized by this building permit application.
Caleb Rounds ea1424 /E 5 8/9/2022
Print Owner's Name(Electronic Signature) Date
SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION
By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
Bill Dailey a .AAv..,QA'� 8/9/2022
Print Owner's or Authorized Agent's Name alectronic Signature) Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at
www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dns
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq. ft.) Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"may be substituted for"Total Project Cost"
CITY OF NORTHAMPTON
SETBACK PLAN
MAP: LOT:
LOT SIZE:
REAR LOT DIMENSION:
REAR YARD
SIDE YARD SIDE YARD_
FRONT SETBACK
FRONTAGE
City of Northampton
÷. SAS... »....SIC
Massachusetts fy'. L .!t�
DEPARTMENT OF BUILDING INSPECTIONS
' " 't 212 Main Street • Municipal Building
Northampton, MA 01060
F^115`'`
CONSTRUCTION DEBRIS AFFIDAVIT
(FOR ALL DEMOLITION AND RENOVATION PROJECTS)
In accordance of the provisions of MGL c 40, S54, a condition of Building Permit
Number is that all debris resulting from this work shall be disposed of in a
properly licensed waste disposal facility, as defined by MGL c 111, S 150A.
The debris will be disposed of in:
Location of Facility: 3 I b I ic,‘p I e y , lJ i- V�; jv,,�,,��� 11,4 023741
The debris will be transported by:
Name of Hauler: , ` . S
Signature of Applicant: , A J Date: / / �
City of Northampton
C(01,17.1.,,,,, 0 "' SAC
Massachusetts ? 't�
t.,( .
DEPARTMENT OF BUILDING INSPECTIONS '
212 Main Street • Municipal Building S`
-`;� Northampton, MA 01060 rgl'Af \%
HOMEOWNERS'EXEMPTION ELIGIBILITY AFFIDAVIT
I, Caleb Rounds (insert full legal name), born _ 'insert month,
day, year), hereby depose and state the following:
1. I am seeking a building permit pursuant to the homeowners' exemption to the permit requi ents of the
Massachusetts State Building Code, codified at 780 CMR 110.R5.1.3.1, in connection with a proje t or work on a
parcel of land to which I hold legal title.
2. I am not engaged in, and the project or work for which I am seeking the aforementioned homeowners'exemption,
does not involve the field erection of manufactured buildings constructed in accordance with 780 CMR 110.R3.
3. I qualify under the State Building Code's definition of"homeowner"as defined at 780 CMR 110.R5.1.2:
Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or
is intended to be, a one-or two-family dwelling, attached or detached structures accessory to such use
and/or farm structures.A person who constructs more than one home in a two-year period shall not be
considered a home owner.
4. I do not hold a valid Massachusetts construction supervision license and, except to the extent th t I qualify for
and will abide by the Massachusetts State Building Code's requirements for the supervision of the roject or work
on my parcel, I am not engaged in construction supervision in connection with any project or ork involving
construction, reconstruction, alteration, repair, removal or demolition involving any activity re lated by any
provision of the Massachusetts State Building Code. 1
5. If I engage any other person or persons for hire in connection with the aforementioned project .r work on my
parcel, I acknowledge that I am required to and will act as the supervisor for said project or work.
Signed under the pains and penalties of perjury on this day of , 20 .
e /ee,.%juts
(Signature)
The Commonwealth of Massachusetts
' _ Department of Industrial Accidents 1
`' Office of Investigations
=j_pp- = Lafayette City Center
= =�`` 2 Avenue de Lafayette, Boston,MA 02111-1750
„• www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/Organization/Individual): Skyline Solar LLC.
Address: 95 Ryan Dr. Suite 3
City/State/Zip: Raynham, MA 02767 Phone#: (732) 354-3111
Are you an employer? Check the appropriate box: Type of project(required):
1.❑■ I am a employer with 85 4. 0 I am a general contractor and I
employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction
2 ❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub-contractors have 8. ❑ Demolition
workingfor me in anycapacity. employees and have workers'
P h' 9. ❑ Building addi 'on
[No workers' comp. insurance comp. insurance.$
required.] 5. 0 We are a corporation and its 10.❑ Electrical rep irs or additions
3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs
insurance required.] t c. 152, §1(4),and we have no 13.® OtherPV Solar System
employees. [No workers'
comp. insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit i icating such.
:Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those tities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: Berkley Casualty Company
BNUWC0156055
Policy for Self-ins. Lic. #: Expiration Date: 1/30/23
Job Site Address:25 Hampden Street Citylbtate/Zip: Northampton, MA 01060
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify under)(C&'tL41U. _
the pains and p es of perjury that the information provided above is true and correct.
Signature: o ';'/ Date: 08/09/2022
Phone#: 732-354-3111 v
Official use only. Do not write in this area, to be completed by city or town official.
City or Town: Permit/License #
Issuing Authority(check one):
1❑Board of Health 2❑Building Department 31:City/Town Clerk 4.0 Electrical Inspector 5E'lumbing
Inspector 6.0Other _
Contact Person: Phone#:
I
r Y Information and Instructions
Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for thei employees.
Pursuant to this statute,an employee is defined as"...every person in the service of another under any contract of hire,
express or implied, oral or written."
An employer is defined as"an individual, partnership,association, corporation or other legal entity,or any o or more
of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employ r, or the
receiver or trustee of an individual,partnership, association or other legal entity, employing employees. H wever the
owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the
dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house
or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer."
MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or
renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any
applicant who has not produced acceptable evidence of compliance with the insurance coverage required."
Additionally, MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall
enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance
requirements of this chapter have been presented to the contracting authority."
Applicants
Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your siyuation and, if
necessary, supply sub-contractor(s) name(s), address(es) and phone number(s) along with their certificate(s of
insurance. Limited Liability Companies (LLC) or Limited Liability Partnerships(LLP) with no employees other than the
members or partners,are not required to carry workers' compensation insurance. If an LLC or LLP does have
employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial
Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should
be returned to the city or town that the application for the permit or license is being requested, not the Department of
Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a w rkers'
compensation policy,please call the Department at the number listed below. Self-insured companies shoul 1 enter their
self-insurance license number on the appropriate line.
City or Town Officials
Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom
of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant.
Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant
that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current
policy information (if necessary) and under"Job Site Address"the applicant should write "all locations in 1 (city or
town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the
applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each
year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture
(i.e. a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit.
The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions,
please do not hesitate to give us a call.
The Department's address,telephone and fax number:
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
Lafayette City Center, 2 Avenue de Lafayette
Boston, MA 02111-1750
Tel. (617) 727-4900 or 1-877-MASSAFE
Revised 7-2019 Fax (617) 727-7749
www.mass.gov/dia
DEBRIS DISPOSAL AFFIDAVIT
In accordance with the provisions of M.G.L. c. 40, s. 54, Building Permit
# was issued with the condition that all debris resulting
from this work shall be disposed of in a properly licensed solid waste
disposal facility as defined by M.G.L c. 111, s. 150A.
The debris will be disposed of in:
E.O.M.S
Name of Waste Facility
318 Manley St.West Bridgewater, MA 02379
Address of Waste Facility
111.5 Debris: As a condition of issuing a permit for the demolition, renovation,
rehabilitation or other alteration of a building or structure, M.G.L.c.40 s. 54 requires
that the debris resulting therefrom shall be disposed of in a properly licensed solid waste
disposal facility as defined by M.G.L.c. 111 s. 150 A.Signature of the permit applicant,
date and number of the building permit to be issued shall be indicated on a form provided
by the Building Department and attached to the office copy of the building permit
retained by the Building Department. If the debris will not be disposed of as indicated,
the holder of the permit shall notify the building official, in writing,as to the location
where the debris will be disposed.
780 CMR—6th Edition
1
ig . ire of Permit Applicant
06/01/2022
Date
Wcgo.NsuunN
., <<. �.�...•L• 4 76 North Meadowbrook Drive
Scott E. Wyssling, PE Alpine, UT 84004
Coleman D. Larsen, SE, PE office (201) 874-3483
Gregory T. Elvestad, PE swyssling@wysslingconsulting.com
August 5, 2022
Empower Energy Solutions
30 Old Kings Highway South#1001
Darien, CT 06820-4551
Re: Engineering Services
Rounds Residence
25 Hampden Street, Northampton MA
7.460 kW System
To Whom It May Concern:
We have received information regarding solar panel installation on the roof of the above referenced
structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability
to support the additional loads imposed by the proposed solar system.
A. Site Assessment Information
1. Site visit documentation identifying attic information including size and spacing of framing
members for the existing roof structure.
2. Design drawings of the proposed system including a site plan, roof plan and connection
details for the solar panels. This information will be utilized for approval and construction
of the proposed system.
B. Description of Structure:
Roof Framing: 2x6 Dimensional Lumber Framing members 24" on center.
Roof Material: Composite Asphalt Shingles and Slate Roofing
Roof Slopes: 34 degrees
Attic Access: Accessible
Foundation: Permanent
C. Loading Criteria Used
• Dead Load
o Existing Roofing and framing = 7 psf
o New Solar Panels and Racking = 3 psf
o TOTAL = 10 PSF
• Live Load = 20 psf(reducible)—0 psf at locations of solar panels
• Ground Snow Load = 40 psf
• Wind Load based on ASCE 7-10
o Ultimate Wind Speed = 117 mph (based on Risk Category II)
o Exposure Category C
Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance
with the 2015 International Residential Code, including provisions allowing existing structures to not
require strengthening if the new loads do not exceed existing design loads by 105% for gravity
elements and 110%for seismic elements. This analysis indicates that the existing framing members
will support the additional panel loading without damage, if installed correctly.
•
Page 2 of 2
D. Solar Panel Anchorage
1. The solar panels shall be mounted in accordance with the most recent Ironridge and Solar Slate
installation manuals. If during solar panel installation, the roof framing members appear unstable
or deflect non-uniformly, our office should be notified before proceeding with the installation.
2. The maximum allowable withdrawal force for a 5/16"lag screw is 235 lbs per inch of penetration as
identified in the National Design Standards (NDS) of timber construction specifications. Based on
a minimum penetration depth of 2'/W', the allowable capacity per connection is greater than the
design withdrawal force (demand). Considering the variable factors for the existing roof framing
and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of
2'/2"embedment will be adequate and will include a sufficient factor of safety.
3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of
the roof, the panel supports shall be placed no greater than 48"on centers.
4. Panel supports connections shall be staggered to distribute load to adjacent framing members.
Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing
roof system will adequately support the additional loading imposed by the solar system. This evaluation is in
conformance with the 2015 IRC,current industry standards and practice,and is based on information supplied
to us at the time of this report.
Should you have any questions regarding the above or if you require further information do not hesitate to
contact me.
AulYYou rs,s, ,�
eikvilps, -/ JScott E.WyssliE
MA License No.505
C
a /
(If
i NI �N
9pi, FG,s-el" _17
MA.. r
e
Signed: 8/5/2022
moo
ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES INDEX
A AMPERE 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED
AC ALTERNATING CURRENT - - {)ISGONNEGTING-MEANS-MAYBE ------ " , ' -E• •TIONING-INVERTER. ---- -- __ PV1 COVER SHEET
BLDG BUILDING ENERGIZED IN THE OPEN POSITION,A 2. THIS SYSTEM HAS NO BATTERIES,NO UPS.
CONC CONCRETE PV2 SITE PLAN
SIGN WILL BE PROVIDED WARNING OF 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY
C COMBINER BOX THE HAZARDS PER ART.690.17. GROUNDED. PV3 ARRAY DETAIL
D DISTRIBUTION PANEL
DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED.
EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE PV4 STRUCTURAL VIEWS
(E) EXISTING IDENTIFIED BY PHASE AND SYSTEM PER
EMT ELECTRICAL METALLIC TUBING ART.210.5. PV5 SINGLE LINE
GALV GALVANIZED 3. A NATIONALLY-RECOGNIZED TESTING VICINITY PV6 LABEL SET
GEC GROUNDING ELECTRODE CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT R T s
GND GROUND IN COMPLIANCE WITH ART.110.3.
HDG HOT DIPPED GALVANIZED 4. CIRCUITS OVER 250V TO GROUND SHALL
I CURRENT COMPLY WITH ART. 250.97,250.92(B)
Imp CURRENT AT MAX POWER ,OF M4 ,
INVS INVERTERS 5. DC CONDUCTORS EITHER DO NOT ENTER ap'
Ise SHORT CIRCUIT CURRENT BUILDING OR ARE RUN IN METALLIC ..._ •1
kVA KILOVOLT AMPERE RACEWAYS OR ENCLOSURES TO THE _ APPLICABLE CODE'i I2 �Y� N �,
kW KILOWATT FIRST ACCESSIBLE DC DISCONNECTING1. 2015 IBC I P 1
LBW LOAD BEARING WALL MEANS PER ART.690.31(E). ,f�70NAL
MIN MINIMUM 6. ALL WIRES SHALL BE PROVIDED WITH ^440 2020 NEC iw
(N) NEW STRAIN RELIEF AT ALL ENTRY INTO BOXES "--
NEC NATIONAL ELECTRIC CODE AS REQUIRED BY UL LISTING. AHJ: Signed:8/5/2022
NIC NOT IN CONTRACT 7. MODULE FRAMES SHALL BE GROUNDED
NTS NOT TO SCALE , CITY OF NORTHAMPTON
OC ON CENTER AT THE UL-LISTED LOCATION PROVIDED Sc
P PANEL BOARD BY THE MANUFACTURER USING UL LISTED .,�� 22 MAIN ST#100
PL PROPERTY LINES GROUNDING HARDWARE. . Y} f`
,c, NORTHAMPTON, MA 01060
..:,-
PV PHOTOVOLTAIC 8. ALL EXPOSED METAL PARTS(MODULE 413-587-1240
PVC POLYVINYL CHLORIDE FRAMES,RAIL,BOXES,ETC.)SHALL BE
S SUBPANEL GROUNDED USING UL LISTED LAY-IN LUGS - ,.4. -' UTILITY: NG
SCH SCHEDULE LISTED FOR THE PURPOSE.POSTS SHALL • �cf.
SS STAINLESS STEEL BE MADE ELECTRICALLY CONTINUOUS ,4';
— - - ------ -
SSD SEE STRUCTURAL DIAGRAMS
STC STANDARD TESTING CONDITIONS WITH ATTACHED RAIL. EMPOWER ENERGY SOLUTION
SWH SOLAR WATER HEATER 9. MODULE FRAMES,RAIL,AND POSTS 30 OLD KINGS HWY S#1001 DARIEN
TYP TYPICAL SHALL BE BONDED WITH EQUIPMENT • CT,06820-4551
UON UNLESS OTHERWISE NOTED GROUND CONDUCTORS AND GROUNDED
/
UPS UNINTERRUPTIBLE POWER SUPPLY AT THE MAIN ELECTRIC PANEL. „I, LICENSES
✓ VOLT 10. THE DC GROUNDING ELECTRODE ,- ?" r/'%, HIC:198351
Vmp VOLTAGE AT MAX POWER CONDUCTOR SHALL BE SIZED
Vac VOLTAGE AT OPEN CIRCUIT ACCORDING TO ART.250.166(B)8 690.47. ELEC:8209-EL-A1
W WATT �`
3R NEMA 3R,RAIN TIGHT
00,
Illr
JOB NUMBER:203777 UTILITY:NG °"I'B"
ROUNDS,CALEB GeDESCRIPTION.DESCRIPTION.ROUNDS RESIDENCE DESIGNED BY:
HA PAGE:
EM? TVWER RACKING:IRONRIDGEXR-100 UTILITYACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEW BY.
ENERGY SOLUTIONS MS PVi
MODULES:(21)LONG!L.R4B-355M NORTHAMPTON,MA,01060 6.00 kW AC ATE
INVERTER:(1)SOLAREDGE INVERTER SE6000H-US(6.00KW) +1-413-559-1698 BBa6/2022 PAGE NAME COVER SHEET
�..; LEGEND
SCALE:1"=15' M UTILITY METER
i—
INV INVERTER
U7
11J A4 AC DISCONNECT
0
a.
DRIVEWAY 2
G MSP MAIN SERVICE PANEL
B DC JUNCTION BOX
N MONITORING UNIT
® = D DISTRIBUTION PANEL
LC LOAD CENTER
ATS AUTOMATIC TRANSFER
SWITCH
a�3"of"1usoot
CONDUIT
v,Y ' / y '� 0 0 0 0 o FENCE
O� •1 P�j
FSSIONA. e
Signed:8/5/2022
JOB NUMBER 203777 UnLrrY:NG °YNER ROUNDS
N: DESIGNED BY: PAGE: PV2
ROUNDS,CALEB UROUNDS RESIDENCE HA
EM?ChWE.� RANG:IRONRIDGEXR 100 UTILITY ACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEW BY:
ENERGY SOLuTIO MS
MODULES:(21)LONG!LR4-60HPB355M NORTHAMPTON,MA,01060 6.00 kW AC DATE:
INVERTER(1)SOLAREDGE INVERTER SE6000H11S(6.00 KW)
+1-413-559-1698 PAGE NMIE: SITE PLAN
4ti LEGEND
4.
V - ROOF
RAFTERS
- INVERTER SCALE:V=10' RAIL
- AC DISCONNECT
MA SMART METER 0 MOUNT
AC DISCONNECT ®® OBSTRUCTION
UTILITY METER
MAIN SERVICE PANEL TOTAL PENETRATION COUNT 50
MP1
RAFTER PROFILE 2X6
i CONDUIT RAFTER SPACING 24'
.:-oo
C.J.SPACING 24'
MP1 S PT
ENT 44'
(10) MODULES JUNCTION BOX ROOF PITCH 34'
ARRAY PITCH 3/'
ROOF AZIMUTH 142'
ARRAY AZIMUTH 142•
ROOF SURFACE SLATE ROOF
TYPE SHINGLES
® 11 STORIES 2
ii�.�����.SR ---__-. MP2
� ii�� RAFTER PROFILE 2X6
RAFTER SPACING 24'
C.J.SPACING 2♦'�
MP2 � � ��� ATTACHMENT
ill •
(7) MODULES m� i
SPACINGROOF PITCH 34'
MP3 ARRAY PITCH 34'
riniall. ROOF AZIMUTH 232'
Ii.. (4) MODULES ROOFSUARRAY FACEMUTH z3r
Mp ROOF SURFACE ASP1MLT SHINGLE
D'�IIIj -;SH�F�N TYPE
STORIES 2II `, ,j G
IiI YNy RAFTER PROFILE 2X6
�I • ` RAFTER SPACING24'
�:�,� C.J.SPACING 24'
1 P ATTACHMENT
/ �FFSSIONAI SPACING
eROOF PITCH 34'
ARRAY PITCH 34'
Signed:8/5/2022 ROOF AZIMUTH 63•
'ARRAY AZIMUTH 53'
ROOF SURFACE A9nYLLTBHMGIE
TYPE
STORIES 2
ROOF LEAD
SIGN OFF:
JOB NUMBER 203777 UTILITY:NG oWNER:
ROUNDS,CALEB ESCRIPTI
ROU oROUDN:NDS RESIDENCE DESIGNED BY.
HA PAGEPV3
RO EI #OwEr—!' RI :IRONRIDGEXR 100 UTILITYACCT#:87614-07012 25 HAMPDEN ST 7.46kW DC ROOF SOLAR SYSTEM REVIEWBYENFRGY SOLUTIONS MS
MODULES:(21)LONG!LR4-601-PB-355NI NORTHAMPTON,MA,01060 6.00 kW AC
REV: DATE:
INVERTER(1)SOLAREDGE INVERTER SE6000FI-US(6.00 KW) +1-413-559-1698 05/011I2022 PAGE NAME: ARRAY DETAIL
/ 13' 4" /
SOLAR MODULE —
\ .....
a 2.-5° x �=
RNL ~
L-FOOT `',✓'••
QMSE-LAG SHINGLE f
COMPOSITE SHINGLE -- /
S"X,,;°-LAG
2.5"MIN.EMBEDMENT ---/ STANDOFF
PER SCREW St SCALE NTS
1 5'-f 5"/- 2X6 NOMINAL --.
S1
MP1 SIDE VIEW
S1
NTS
RAFTERS'.2X6 a 24"O.C. s01 P,,bx f,V E
MAX SPAN-12' ppW
•
Brae.
`.. SLATE PLATE FLASH iNG --- .vim'
n
YJ�yd-
MP2&3 SIDE VIEW i�
:, NTSfw
/ '.;pF Gr T RAFTERS 2X6 @ 24 O.C. CONCRETE TILE SLATE ROOF /
fSSIpaA%. li Ai MAX SPAN-8' / #STANDOFF
Iii; ----- -------- SCALE NTS
Signed:8/5/2022 7W NOMINAL -
JOB NUMBER 203777 UTILITY:NGOWNF-It ROUNDS,CALEB ROUN DESCRIPTION
RESIDENCE DESIGNED BY: PAGE: PV4
HA
EM?OWEm RACKING:IRONRIDGEXR100 UTILITY ACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEW"'
ENERGY SOLUTIONS MS
MODULES:(21)LONGI LR4-60HPB-355M NORTHAMPTON,MA,01060 6.00 kW ACREV DATE.
INVERTER(1)90LAREDGE INVERTER SE600011-US(6.00 KW)
+1-413-559-1698 O5U8/2022 PAGE NAME: STRUCTURAL VIEWS
♦ BREAKER
FUSE
-- SWITCH
= EARTH GROUND
---- GEC
INVERTER OUTPUT CURRENT(A)= 25
EGC
1201210v INVERTER BACKFEED(A)= 31
SINGLE
OVVERRHEADE O MSP RATING(A)= _ 100
UTILITY SERVICE MAIN BREAKER RATING(A)= 100
MAX BACKFEED(A)= 20
METER TIE IN: LST
2502624
J ■ ■ ■ ■
(N)SOLADECK
JUNCTION BOX
(N)SOLAREDGE INVERTER -UNFUSED (N)(21)LONOI UtL60HPSJ55M 355W PV MODULES
SE6000H-US -GROUNDED (21)SOLAREDGE P370 POWER OPTIMIZERS
LINE SIDE TAP
(N)BOA AC DISCONNECT (N)BOA AC DISCONNECT
-FUSIBLE,LOCKABLE -FUSIBLE.LOCKABLE 1 BRANCH OF 11g7
-20A FUSES (N)MA SMART METER -20A FUSER d
20A METER SOCKET X-2DA -�
11 � 1m \ - 1 BRANCH OF 10
__—__—__—__TL---__—___l _
10DVIP I LIME LOAD LG�-- LIME LOAD I I
�I
I ✓ - J
n (E)LOADS
r--- -
I
= GROUND ELECTRODE
ELEC. LEAD
AWN KR,THWN-2 AWG IN.THWRFS AWO010.TOWN-2 AWO/10,PV WIRE
AND//.THWN-2,EGC/OEC APED IS.THWN-2.EGC/GEC AWG1110,TOWN-2,EIXYOEC AWG MO.THW142EGC SIGN OFF:
CONDUIT,3M'EMS CONDUIT,LI'BAT CONDUIT,3/1'EMT CONDUIT.3M EMT
JOB NUMBER:203777 UTILITY:NG OWNER DESCRIPTION: DESIGNED BY: PAGE:
ROUNDS,CALEB ROUNDS RESIDENCE HA PV5
EA OWEER RACKING:IRONRIDGEXR100 UTILITY ACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEW BY:
ENERGY SOLUTIONS MS
MODULES:(21)LONGILR4-60HPB355M NORTHAMPTON,MA,01060 6.00 kW ACREV DATE.
INVERTER:(1)SOLAREDGE INVERTER SE6000I-I-US(6.00 KW) +1-413-559-1698 05N82O22 PAGE NAME: SINGLE LINE
NOTE:
NEC 690.17(E) BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS
See Figure 690.1(b)diagrams for location in system SHALL COMPLY WITH(IN ORDER OF PRIORITY)AHJ&FIRE
Disconnects PV from all other wiring systems DEPARTMENT AMENDMENTS,STATE CODE,AND ANSI
Installed in a readily accessible location GUIDELINES.THIS PAGE IS INTENDED OR SIGNAGE/LABEL
Permanently marked: PV SYSTEM DISCONNECT, or equivalent VERBIAGE ONLY.
Where line/load may be energized in open (off)position: OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS IS
Marked with the following or equivalent TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT IN
NEC 690.31 (D)2; 2012 IFC 605.11 WHICH THE EQUIPMENT IS INSTALLED.NO STICKERS ARE
On or in a building, unless location/purpose is evident PERMITTED.
WARNING Raceways, enclosures, every 10', suitable for environment 2020 NFPA 70, NEC 690.53
Minimum 3/8" CAPS White on Red, Reflective DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE
Maximum system voltage calculated in accordance with 690.7
ELECTRICAL SHOCK HAZARD • At one of the following locations:
DO NOT TOUCH TERMINALS • DC PV system disconnect
TERMINALS ON BOTH THE LINE AND LOAD WARNING PV system electronic power conversion equipment
SIDE MAY BE ENERGIZED IN THE OPEN • Distribution equipment associated with the PV system
POSITION PHOTOVOLTAIC POWER
SOURCE MAXIMUM VOLTAGE I I
MAXIMUM CIRCUIT CURRENT I I
NEC 705.12(D)(2)(b) MAX RATED OUTPUT CURRENT OF
THPLACE THIS LABEL AT P.O.C. TO SERVICE OR CHARG DC-TO-D CCONTROLLER
OR C CONVERTER I I
DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND 2020 NFPA 70, NEC 690.56(c) ,,(IF INSTALLED) ,
SUBPANEL IF APPLICABLE)) LOCATED AT EACH SERVICE EQUIPMENT LOCATION 2020 NFPA 70, NEC 690.54
WHERE PV IS CONECTED"OR APPROVED READLY VISIBLE LOCATION INTERACTIVE SYSTEM POINT OF INTERCONNECTION
\/J!/\RNING SHALL INCLUDE SIMPLE DIAGRAM OF BUILDING All interactive system(s)points of interconnection with other
AND ROOF sources shall be marked..."
• Accessible location at disconnecting means,
PHOTOVOLTAIC SYSTEM EQUIPPED as a power source:
INVERTER OUTPUT CONNECTION TURN RAPID SHUTDOWN
WITH RAPID SHUTDOWN • Rated AC output current
IC
DO NOT RELOCATE THIS SWITCH TO THE"OFF" '°`ABA""PV PANELS • Nominal operating AC voltage
POSITION TO SHUTDOWN
OVERCURRENT DEVICE PV SYSTEM AND REDUCERAPIO
PHOTOVOLTAIC AC DISCONNECT
SHOCK HAZERD IN THE ARRAY
•�� CTIOCIMIER RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE: r- I
JOB NUMBER:203777 UTILITY:ILITY:NG OWNER DESCRIPTION: DESIGNED BY: PAGE:
ROUNDS,CALEB ROUNDS RESIDENCE HA PV6
EI v P 'VWER RACKING:IRONRIDGEXR 100 UTILITY ACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEWBY:
ENERGY SOLUTIONS MS
MODULES:(21)LONGILR460HPB355M NORTHAMPTON,MA,01060 6.00 kW AC
REV: DATE:
INVERTER(1)SOLAREDGE INVERTER SE6000H11S(6.00 KW)
+1-413-559-1698 05W80022 PAGE NAME LABEL SETS
NEC 705.12(6)(3)(3) "AC Combiner Panel" NEC 690.56(B)/705.10/712.10 2020 NFPA 70, NEC 690.56(c)(2)
Permanent plaque or directory installed at either: SWITCH LABELS THAT INCLUDE THE FOLLOWING:
• Sum of ampere ratings, excluding source OCPD Each service equipment location MINIMUM 3/8"CAPS,WHITE ON RED,REFLECTIVE
• Label applied adjacent to distribution equipment Approved readily visible location REQUIRED FOR ALL SYSTEM TYPES
• The following or equivalent wording: Marked with the following wording: RAPID SHUTDOWN
Denote location of each power source disconnect
Grouped with other plaques or directories SWITCH FOR
WARNINGCorrectly oriented with respect to diagram's location SOLAR PV SYSTEM
CAUTION NEC 690.35 (F)
THE L RATING
FED BY MULTIPLE T SOURCES. PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX,
TOTAL RATING OF ALL OVERCURRENT DEVICE,
EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED
SHALL NOT EXCEED AMPACITY OF BUSBAR. O ILL NO ONION IXAi, CIRCUITS MAY BE EXPOSED DURING SERVICE:
DISCONNECT MOONS MI ENONN MO•
MUTT rote 10* n A
NEC 690.56 (Informational Note)
A, EaMMt WAR N I NJ G
• MA Fire Code (527 CMR 1) requires signage: .L•Et_
• Adjacent to building or service disconnect ELECTRICAL SHOCK HAZARD
• Identifies responsible party for operation NEC 705.12(C) THE PHOTOVOLTDAIC SYSC TEM RS OF THIS
UNGROUNDED
of system Equipment containing overcurrent devices AND MAY BE ENERGIZED
• Provides contact informatio supplying power to busbar or conductor
Supplied from multiple sources NEC 690.5(C)
"Marked to indicate the presence of all sources" PLACE THIS LABEL ON INVERTER(S)OR NEAR
GROUND-FAULT INDICATOR(ON INVERTER(S)U.O.N.)
PV SYSTEM INSTALLATION BY:
ABC SOLAR WARNING
CONTACT PHONE: 857-600-8995 WARNING
IN CASE OF EMERGENCY DIAL 911 ELECTRICAL SHOCK HAZARD
DUAL POWER SOURCE SECOND IF A GROUND FAULT IS INDICATED,
SOURCE IS PHOTOVOLTAIC SYSTEM
NORMAI I Y GROUNflED_CQNDUCT_ORS Y
BE UNGROUNDED AND_ENERGI
JOB NUMBER:203777 UTILITY:NG DWNER DESCRIPTION. DESIGNED BY PV7
ROUNDS,CALEB ROUNDS RESIDENCE HA
EM?t WER RACKING:IRONRIDGE XR-100 UTILITYACCT#:87614-07012 25 HAMPDEN ST 7.46 kW DC ROOF SOLAR SYSTEM REVIEW BY
ENERGY SOW4tONS MODULES:(21)LONGI LR4-60HPB-355M NORTHAMPTON,MA,01060 6.00 kW AC - MS
REV DATE:
INVERTER(1)SOLAREDGE INVERTER SE6000H-US(6.00 KW) +1-413-559-1698 05/0100W PAGE NAME: LABEL SETS
LR4-60HPB
Hi-M04m
-- 345"'370 M (Black)
WBIJIMEWWLTh fThll llu
uuu►=1umuImmuwumrm; Nor',/
WuuBBMI l MERWImrm
IDuumlmWuumlmWuumlm
WuummiWuum0mWuumriu!
MIIIIIMEMBIBIBMINFI High Efficiency
WuumMmWuumrmWuumrm 9 Y
illlWflll=11BMlWuumml
;uummmuummm1=111mn Low LID Mono PERC with
mmimMm uuWuwulmmwuui
., , „ „ ,M1, Half-cut Technology
,mm1Wuum INIWI nmWuu.
:m11DWWIfIEW HIMEWuu
;mmluwumilllWummrmwuu:
IMITIWuuTh ffl mlmWuu:
;mlmWW IIBMI umlTW uI
,mmlIIHRIB wuumrmIM
12-year Warranty for Materials and Processing; �/ �\
25-year Warranty for Extra Linear Power Output O ,' 4. 1 0%
98 25-year Power • /
Additional�alu Warranty Annual �• //
e from LOWGI Soi Power Attenuation �/ -,
91.2% +1.85% arsLrnearWarrant ii -0.55% / ,--
'Ti = / i
87.7% _--_ Standard Module linear +2.600% Y ///��
Power warrant), +3.35%
84.5% -. _
1 5 10 15 20 25
Complete System and Product Certifications Positive power tolerance(0"+5W)guaranteed
IEC 61215,IEC 61730,UL 61730
High module conversion efficiency(up to 20.3%)
ISO 9001:2008:ISO Quality Management System
ISO 14001:2004:ISO Environment Management System Slower power degradation enabled by Low LID Mono PERC technology:first year<2%,
TS62941:Guideline for module design qualification and type approval 0.55%year 2-25
OHSAS 18001:2007 Occupational Health and Safety
Solid PID resistance ensured by solar cell process optimization and careful module BOM
+a selection
a�. EI
o us �i Reduced resistive loss with lower operating current
*Specifications subject to technical changes and tests. Higher energy yield with lower operating temperature
LONGi Solar reserves the right of interpretation.
Reduced hot spot risk with optimized electrical design and lower operating current
■
I.O I1 G I Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China
Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar
Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such
modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of
lawful documentation duly signed by both parties.
20200410V11 for US-D
LR4-60HPB 345,...,370M
Design(mm) Mechanical Parameters Operating Parameters
1038
o = \ Cell Orientation:120(6x20) Operational Temperature:-0 C-+85 C
Ilt1 IIIL1 -IIII111IIIL1III1111111 -
1111111-I I III IIJ III 1 ❑ 9 Junction Box:IP68,three diodes Power Output Tolerance:0"+5W
III _ 1 III II l "
III III 11 I III III _ ♦ r31 - Output Cable:4mm',1200mm in length Voc and Isc Tolerance:±3%
I' 1 I IIIIII 1 1111111111 rV,
IIIIII I II IIII I Glass:Singleglass
10L11I II I�II 111111111
ngl glass Maximum System Voltage:DC1001T/(IEC/UL)
'11011101111f IIILluuuul
I I I I I LL I I( I ll I I I I I( 1.II 3.2mm mated tempered glass Maximum Series Fuse Rating:20A
IIII-.0 e 5I5 L� JI I N$§ - IL.. Frame:Anodized aluminum alloy frame Nominal Operating Cell Temperature:45±2 C
II _ I11lt _ IIIIII
sII`II IIII,III(,l ll Weight:19.5kg Safety Class:Class 11
tIIIII, I, I ((I mu unto:mmciada
Dimension:1755x1038 35mm Fire Rating:UL type 1 or 2
11 II11 ll1 IIIIIIIIIIII Tom.(Ili IIJIIIIL III IIlIIII •
ILength m2mm Padaging:30pcs per pallet
.11 IIII 1 II ii 1 `992 want z2mm
Hid IIIIril I IIII III1hiiii0 IIII Loch)tarn 180pcsper20'GP
,UI 11111U1II1 11111111%11111 _ ,- -Z Rto-mwslmm 780pcs per 40'HC
Electrical Characteristics Test uncertainty for Pmax:±3%
Model Number LR4-60HPB-345M LR4-60HPB-350M LR4-60HPB-355M LR4-6OHPB-360M LR4-60HPB-365M LR4-60HPB-370M
Testing Condition STC I NOCT STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT
Maximum Power(Pmax/W) 345 I 257.6 350 261.4 355 265.1 360 i 268.8 365 272.6 370 276.3
Open Circuit Voltage(Voc/V) 40.2 I 37.7 40.4 37.9 40.6 38.1 40.8 38.2 41.0 38.4 41.2 • 38.6
Short Circuit Current(Isc/A) 11.06 : 8.95 11.16 ! 9.02 11.25 9.09 11.33 9.16 11.41 9.23 11.50 ! 9.30
Voltage at Maximum Power(Vmp/V) 34.2 31.8 34.4 : 32.0 34.6 32.2 34.8 32.4 35.0 32.6 35.2 32.8
Current at Maximum Power(Imp/A) 10.09 ; 8.09 10.18 8.16 10.27 • 8.23 10.35 8.30 10.43 8.36 10.52 . 8.43
Module Efficiency(%) 18.9 19.2 19.5 19.8 20.0 20.3
STC(Standard Testing Conditions):Irradiance 1000W/m2,Cell Temperature 25 C,Spectra at AM1.5
NOCT(Nominal Operating Cell Temperature):Irradiance 800W/m2,Ambient Temperature 20 C,Spectra at AM1.5,Wind at 1m/S
Temperature Ratings(STC) Mechanical Loading
Temperature Coefficient of Isc +0.048%/C Front Side Maximum Static Loading 5400Pa
Temperature Coefficient of Voc -0.270%/C Rear Side Maximum Static Loading 2400Pa
Temperature Coefficient of Pmax -0.350%/C Hailstone Test 25mm Hailstone at the speed of 23m/s
I-V Curve
Current-Voltage Curve(LR4-60HPB-360M) Power-Voltage Curve(LR4-60HPB-360M) Current-Voltage Curve(LR4-60HPB-360M)
12 4m Cell temp=25C 12 Cell Temp=25C
10 - 350 -1000w/m' 10 -
lnuaemlr.aa..taaow/m' 3m -WOW.'
-s00w/m' eao./m'
b -Celli p=25C j ::
-400w/m'-411T p=35C -200w/m'6 - -CMT MSC 0 6
u -Cell Tempw55C
u 4 - -Cell T p=65 C 150 a 4 -400w/m'
-Cell Temp=75C 100
2 50 2 -200w/m,.,__......._...._..- -�..�\
0 10 20 30 40 50 0 10 20 30 40 50 D 10 20 30 40 50
Voltage(v) Voltage(v) Voltage(v)
..
I.O N G I Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Furlong Shanghai,200120,China
Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar
Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such
modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of
lawful documentation duly signed by both parties.
2 0200410V11 for US-D
/ Single Phase Inverter—
With HD-Wave Technology for North America
Single Phase I ever er SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/
with HD-Wave Technology SE7600H-US/SE10000H-US/SE11400H-US
mMODEL NUMBER !SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US 1 SE10000H-US SE11400H-US._
for North America APPLICABLE TO INVERTERS
WITH PART NUMBER SE)000(H-10000tB10(4
SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ OUTPUT
SE7600H-US/SE10000H-US/SE11400H US Rated AC Power 3x0 3002V Sti0 6000@z4ov eco xoo 400 @ VA
i..� 33 0
00 208V 5000 @ 208V @ 208V240V
Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7fi00 10000 114iT0 @ 240V VA
71
12-25 3300.2oeV s000 o zaev 10000 @ 208V .
AC Output Voltage Min.-Nora:Max V .' / I , Vac
-._._ _......:..... y IZ71-240-264)
•O WARRANTY' LA AC Output Voltage Min.-Nom-Max. - ( - - - I
(183-208-229)
AC Frequency(Nomnap 59.3-60-60.50 Vac
Hz
• • - -
Maximum Continuous Output 125 16 21 25 32 42 47.5 A
Current 0240V
Maximum Continuous Output - 16 - 24 - - 48.5 A
Current @ZO8V _ _ _ _
• • Power Factor 1,Adjustable-0.85 to 0.85
O • GFDI Threshold 1 A
•
Utility Monitoring,ISWding Protection Its
Country Configurable Thresholds
INPUT
• Solar,T9t1' ,_,FiD • • nniur=T 10 @ Maximum DC Power @240v 4650 5900 7750 9300 11800 15500 17650 W
Maximum DC Power @208V 5100 7750 15500 W
h _— __ ,. Transfunner-less.Ungrounded Vs
• • Maximum Input Voltage 480 Vic
• 0 - Nominal DC Input Voltage 380 400 Vic
lip Maximum Input Current P)240V01 8.5 10.5 13.5 16.5 • 20 27 30.5 Adc
• Maximum input Current @208V0 - 9 - 13.5 - 1 - 27 Adc
Max Input Short Circuit Current 45 Adc
•i • O • Reverse-Polarity Protection Its
^'v,-- - - - --- - • _ Ground-Fault Isolation Detection 6001m Sensitivity
Maximum Inverter EBiciency 99 I 99.2 %
CEC Weighted Efficiency 99 99.240V %
98.5.208V
Nighttime Power Consumption n 2.5 W
Optimized installation with HD-Wave technology ^Ep,other2�d f ng,Pl co
ntact --
^A higher CWT.sowace may be used:the inverter will limit it input crown to the values sated
/ Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance
/ Record-breaking 99%weighted efficiency / Small,lightweight,and easy to install both outdoors
or indoors
/ Quick and easy inverter commissioning directly
from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring
/ Fixed voltage inverter for longer strings / Optional:Faster installations with built-in consumption
metering(1%accuracy)and production revenue grade
/ Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20)
shutdown for NEC 2014 and 2017,per article
690.11 and 690.12
solaredge.com solar
/ Single Phase Inverter
With H D-Wave Technology for North America
SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/
SE7600H-US/SE10000H-US/SE11400H-US
MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
ADDITIONAL FEATURES
Supported Communication Interfaces R5485,Ethernet Zigeee(optional).Cellular(optional)
Revenue Grade Metering,ANSI
C12.20
OptionaNa
Consumption metering
Inverter Commissioning With the SetApp mobile appkation using Built-in Wi-Fi Access Point for Local Connection
Rapid Shutdown-NEC 2014 and i
2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741.UL1741 SA,UL1699B,CSA C222,Canadian AFC'according to LI.L M-07
Grid Connection Standards IEEE1547,Rule 21,Rule 14(Hf
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Sue/AWG T'Maximum/14-6 AWG 1"Maximum/14-4 AWG
Range
DC Input Conduit Size/C of Strings/ N Maximum/1-2 strings/14-6 AWG T'Maximum/1-3 strings/14-6 AWG
AWG Range
Dimensions with Safety Switch 17.7 x14.6a6.8/450 x370 x174 21.3 x 14.6 x73/540 x 3700185 n/
(HXW%D) mm
Weight with Safety Switch 22/10 I 25.1/11.4 26.2/119 38.8/17.6 b/kg
Noise <25 <50 dBA
Cooling Natural Convection
Operating Temperature Range -40 to+140/-40 to+6014 'F/-C
Protection Rating NEMA 4%(Inverter with Safety Swatch)
n Inverter with revenue Grade Meter PM:SEmo 1-US000fNC4;Inverter with Revenue Grade Production and Consumption Meter PM:SEno00-1150008N11.Foe consumption metering,anent transformers
should be ordered separately SEACT0750-200NA-20 or SEACT0750-I00NA-20.20 units per bar
Ful pourer up to at Ban 50'C/122'F,for power de-rating information refer to hops//wwwsdaredgecom/sbes/defaillgfies/so-renperature-derating-noo-ru.pdf
How to Enable Consumption Monitoring
By simply wiring current transformers through the inverters existing AC conduits and connecting them to the service panel,homeowners will gain full insight into their
household energy usage helping them to avoid high electricity bills
Single phase with .
HD-wave technology and
built-in-in ROM and
Service Panel consumption monitoring
Grid O'—'^'
CT Li N 12
Shielded CATSe cable S
L7
laureimium
Pre
u
AC Candor
',edema.mentioned
air area
r ea merrM.SOWeEnGEMeohhdgeksga.OPTIMUM ev soIeeas anamiaaaorregin t vadrn..NsahrragareMmuaiex le ellRoHS
°Met dema.me ed harm a trademarks of their respective owners.oats:01,0ZONOI IG MK Sul ea change nhout notice.
Power Optimizer
O
For North America
P370 / P400 / P401 / P485 / P505
m
70
25 O YEAR
WARRANTY
111.11.1
i
N
m
713
PV power optimization at the module-level
/ Specifically designed to work with SolarEdge / Fast installation with a single bolt
inverters
/ Next generation maintenance with module-
/ Up to 25% more energy level monitoring
/ Superior efficiency (99.5%) / Meets NEC requirements for arc fault
protection (AFCI) and Photovoltaic Rapid
/ Mitigates all types of module mismatch losses, Shutdown System (PVRSS)
from manufacturing tolerance to partial
shading / Module-level voltage shutdown for installer
and firefighter safety
/ Flexible system design for maximum space
utilization
solaredge.com solar • •
/ Power Optimizer
For North America
P370 / P400 / P401 / P485 / P505
Optimizer model P370 P400 P401 P485 P505
(typical module compatibility) (for higher-power 60 (for 72&96- (for high power 60 (for high-voltage (for higher
and 72-cell modules) cell modules) and 72 cell modules) modules) current modules)
INPUT
Rated Input DC Powernt 370 400 485 505 W
Absolute Maximum Input Voltage 60 80 60 1250 830 Vdc
(Voc at lowest temperature)
MPPT Operating Range 8-60 8-80 8-60 12.5-105 12.5-83 Vdc
Maximum Short Circuit Current(Ix) 11 10.1 11.75 11 14 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8
Overvoltage Category II
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15 Adc
Maximum Output Voltage 60 80 Vdc
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer 1±0.1 Vdc
STANDARD COMPLIANCE
Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 NEC 2014,2017&20201 NEC 2014,2017&2020
EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(class II safety),UL1741
Material UL94 V-0,UV Resistant
RoHS Yes
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage 1000 Vdc
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
Dimensions(WxLxH) 129x153x27.5/5.1x6 129 x153 x 33.5/ 129x153x29.5/5.1x6 129x153x33.5/5.1 129x162x59/ mm
x 1.1 5.1 x 6 x 1.3 x 1.16 _ x 6 x 1.3 5.1x6.4x2.3 /in
Weight(including cables) 655/1.4 750/1.7 655/1.4 845/1.9 1064/2.3 gr/lb
Input Connector MC40, Single or dual MC4140 MC40,
Input Wire Length 0.16/0.52,0.9/2.9501 0.16/0.52 0.16/0.52,0.9/2.950 0.16/0.52 0.16/0.52 m/ft
Output Wire Type/Connector Double Insulated/MC4
Output Wire Length 1.2/3.9 m/ft
Operating Temperature Rangeni -40 to+85/-40 to+185 'C/'F
Protection Rating IP68/NEMA6P
Relative Humidity 0-100 %
(1) Rated power of the module at STC will not exceed the optimizer'Rated Input DC Power.Modules with up to+5%power tolerance are allowed
(2) NEC 2017 requires max input voltage be not more than 80V
(3)For other connector types please contact SolarEdge
(4) For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected
to one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals
(5) For ambient temperature above+85'C/+185°F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details
PV System Design Using a SolarEdge Single Phase Sin le hase Three Phase for Three Phase for
Inverter161111 HD-Wave g P 208V grid 277/480V grid
Minimum String Length P370,P400,P401 8 10 18
(Power Optimizers) P485,P505 6 8 14
Maximum String Length(Power Optimizers) 25 25 50
Maximum Nominal Power per String 57001e(6000 with 5250m 6000w 12750m W
SE7600-US-SE11400-US)
Parallel Strings of Different Lengths or Orientations Yes
(6) For detailed string sizing information refer to:http.//www.solaredge.corn/sites/default/files/stnng_sizing_sa.pdf
(7) R is not allowed to mix P485/P505 with P370/P400/P401 in one string
(8) If the inverters rated AC power maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power.Refer to:httpsy/www.solaredge.
corrvsites/default/files/se-poweroptimizer-single-string-design-application-note.pdf
(9) For 208V grid:it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W
(10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W
O SolarEdge Technologies Ltd.All rights reserved.SOLAREDGS the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, cC I,us Ro H S
Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:04/2021 DS-000044-2.0-NA.Subject to change without notice
Intertek
Trcir Br el
//r►.IRONRIDGE XR Rail Family XR Rail Family
The XR Rail Family offers the strength of a curved rail in three targeted sizes.Each size supports specific
Solar Is Not Always Sunny design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match.
Over their lifetime,solar panels experience countless -
extreme weather events.Not just the worst storms in years,
but the worst storms in 40 years.High winds capable of ;- -
ripping panels from a roof,and snowfalls weighing =%
,i,_
enough to buckle a panel frame. { -...,' ,� �r : ;
.... ... = _,,, ,
XR Rails are the structural backbone preventing + + XR10 XR100 XR1000
these results.They resist uplift,protect f j +
against buckling and safely and efficiently '"�., a * %R10 is a sleek low-prolila mounting XR100 is me ummate reeidenhal %R1000 is a heavyweight among
transfer loads into the building structure. _ rad.designed forregions with Ighl or mounting rail.h supports a range of solar mounting rails.Ifs bug to handle
Their superior spanning capability rq snow.I M es spans up to 6 feet, wind and snow ccndrr ons whie also e.,neme akmeles and spans ap tot 12
requires fewer roof attachments, . -- while remaining light end economical xi mam n to spans up 10 lest. leer for commercial applications
reducing the number of roof -�^ • 6'spanningcepollly • 10spansngcapability • 12'spannngcapability
penetrations and the amount �''.� �` - • Moderate bed capability • Heavy load capehiliry • Extreme toed capability
• Clear 8 black anodized finish • Clear 6 deck anodized finish • clear anodized finish
of installation time. • Internal splices available • Internal splices available • Internal splices available
Rail Selection
V The table below was prepared in compliance with applicable engineering codes and standards.`Values are
based on the following criteria:ASCE 7-16,Gable Roof Flush Mount,Roof Zones 1&2e,Exposure 8,Roof
Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters.
Load Rail Span
Snow(PSF) Wind(MPH)Mal 6'4" 6'.. 8' 10' 12
` '- Force-Stabilizing Curve 1 i 90
't z' ' Sloped 1 generate both vertical and lateral i j
..,` force t ng Is which can cause them I t 20
` " .. to bend d twist Thecurved shape of XR Rails None
sp,n uy da g ea to nnrea,�svergN m both 140 XR10 ,i ,,:...
ma' directionswhileresisting the twisting This unique ,• _,.. ��. -
+ Mature ensures greater security during extreme 160
weather and a longer system lifetime.
ii
Y 93
1220
- j 20
140
160
30 90 ,: S x .__... 4
160
Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90
XR Rads are IronRtlge offers All%R Rods are made of 0000-Sens 40
campanile Olin o range of fir leg alum sum alloy Ines protected w In on �' 160
FlashFool aol options for flat anodized f nrsh.Anodizing prevents surface
other etched root roof mounting and structural corrosion wh b also provloing r 80 160 1
ariachmenls. apVkcatgns. a more attractive appearance. •�°
120 160 { ',„-
e 2020 hwraleg..MI.AN.atts mwv.d.VIM www.mreW0..corn orcat 140e321-9022 for more.aonnevon.onion 110 /lrME