30D-016 278 Burts Pit Road Site Plan Application Site Plans -R5-12-22Drawn by:
Checked by:
BC
Scale:
Project No.
see aboveDate:
C
File: Habitat-Pelham.pln Print Date: 4/11/21Bruce Coldham FAIAConceptfor Habitat for Humanity(Single Story Dwelling Unit)Owner's Consultants
Civil Engineer
TBD
Environmental Design Consultant
TBD
Architect's Consultants
Structural Engineer:
TBD
Building Design:
Michael Broad
Leverett, MA
WINDOW SCHEDULE
MARK
A
B
B
C
D
E
F
G
QUANTITY
13
1
4
3
2
2
1
2
MANUFACTURER MODEL NO.SIZE ( WIDTH X HEIGHT)
3'-0"x5'-0"
2'-6"x2'-6"
5'-0"x5'-0"
2'-6"x4'-0"
2'-0"x3'-6"
2'-6"x5'-0"
2'-6"x3'-8"
2'-6"x3'-6"
AREA
15.00
6.41
25.00
10.00
7.00
12.50
9.17
8.75
TYPE REMARKS
2017%01%01&&
&
A3 Elevs Dwg Notes.docx&
&
{Note: When PDF’ing - use custom paper size 5”x36”}&
&
&
&
EXTERIOR ELEVATION NOTES
1.All dimensions are to face of framing, top of sub-floor, or top or face of
concrete unless otherwise noted.
2.Mounting Blocks in plane of siding for power outlet, hose bib,
ventilation duct, lighting fixture or similar penetrations shall of the same
material and material thickness as exterior trim material — 5/4
Mounting blocks shall be canted at the top edge and have a top flashing
— formed aluminum in color to match siding or trim.
&
-4'-6"
Foundation
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
GUTTER &
DOWNSPOUT.
DRYER VENT
PV ARRAY INSTALLED OVER ASPHALT SHINGLE ROOFING (TBD)
TWO AIR SOURCE HEAT PUMP
OUTDOOR UNITS STACK-MOUNTED
ON GALVANIZED STEEL FRAME ON
CONCRETE PAD ON MILDLY
COMPACTED GRADE
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 3)
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)
HOSE BIB, 18"
ABOVE GRADE ELECTRIC GFI EXT. RECEPTACLE
GA G B B C
ASPHALT SHINGLE ROOF
COVERING
ASPHALT SHINGLE ROOF
COVERING
VINYL SIDING;
4" EXPOSURE
-4'-6"
Foundation
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
4X4 POST CASED
IN 1 X ... WOOD;
(TYP. OF 3)
ERV AIR GRILL 0N MOUNT BLOCK (MECHANIC TO
DETERMINE WHETHER INTAKE OR EXHAUST)
RANGE HOOD EXHAUST -
IN EXTERIOR WALL (OBSCURED)
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
TWO AIR SOURCE HEAT PUMP
OUTDOOR UNITS STACK-MOUNTED
ON GALVANIZED STEEL FRAME ON
CONCRETE PAD ON MILDLY
COMPACTED GRADE
HOSE BIB, 18"
ABOVE GRADE
ELECTRIC GFI EXT.
RECEPTACLE
A
ASPHALT SHINGLE ROOF
COVERING
-4'-6"
Foundation
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
10'-0"LIGHT FIXTURE ;
SEE LIGHTING PLAN
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
CORNER BOARD —
5/4 X 6 VINYL
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)
A D
VINYL SIDING;
4" EXPOSURE
VINYL SIDING;
4" EXPOSURE
-4'-6"
Foundation
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
TWO AIR SOURCE HEAT PUMP OUTDOOR UNITS STACK-
MOUNTED ON GALVANIZED STEEL FRAME ON
CONCRETE PAD ON MILDLY COMPACTED GRADE
ELECTRIC GFI EXT.
RECEPTACLE
ELECTRIC SERVICE
PANEL AND METER
BOARD 4'W X 4'H —
SUFFICIENT SPACE FOR
PV INVERTER
ERV AIR GRILL 0N MOUNT BLOCK (MECHANIC TO
DETERMINE WHETHER INTAKE OR EXHAUST)
A A
SCALE: 1' = 1'-0"
WINDOW SCHEDULE 01
A3.1
SCALE: 3/16" = 1'-0"
ELEVATION
SCALE: 3/16" = 1'-0"
ELEVATION
SCALE: 3/16" = 1'-0"
ELEVATION
SCALE: 3/16" = 1'-0"
ELEVATION
Drawn by:
Checked by:
BC
Scale:
Project No.
see aboveDate:
C
Concept Elevationsfor Habitat for Humanity(Two Story Dwelling Unit)File: Habitat-Pelham.pln Print Date: 4/11/21Bruce Coldham FAIAOwner's Consultants
Civil Engineer
TBD
Environmental Design Consultant
TBD
Architect's Consultants
Structural Engineer:
TBD
Building Design:
Michael Broad
Leverett, MA
-4'-6"
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
ERV AIR GRILL 0N MOUNT BLOCK (MECHANIC TO
DETERMINE WHETHER INTAKE OR EXHAUST)
ELECTRIC GFI EXT. RECEPTACLE
(west side of door)
RANGE HOOD EXHAUST -
IN EXTERIOR WALL
CONCRETE; EXPOSED
ERV AIR GRILL 0N MOUNT BLOCK (MECHANIC TO
DETERMINE WHETHER INTAKE OR EXHAUST)
E
D
F
C
E
ASPHALT SHINGLE ROOF
COVERING
ASPHALT SHINGLE ROOF
COVERING
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
HOSE BIB AT 18"
ABOVE GRADE
PV ARRAY INSTALLED OVER ASPHALT SHINGLE ROOFING (TBD)
TWO AIR SOURCE HEAT PUMP
OUTDOOR UNITS STACK-MOUNTED
ON GALVANIZED STEEL FRAME ON
CONCRETE PAD ON MILDLY
COMPACTED GRADE
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)
ELECTRIC GFI EXT. RECEPTACLE4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)
VINYL SIDING;
4" EXPOSURE
ASPHALT SHINGLE
ROOF COVERING
ASPHALT SHINGLE
ROOF COVERING
A
BB
A
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
9'-3"GUTTER &
DOWNSPOUT
DRYER VENT
LIGHT FIXTURE ;
SEE LIGHTING PLAN
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)HOSE BIB AT 18"
ABOVE GRADE
VINYL SIDING;
4" EXPOSURE
ASPHALT SHINGLE
ROOF COVERING
A A
A C
±0"
FIRST FLOOR
+8'-11"
SECOND FLOOR
+17'
ROOF – Top Plate
TWO AIR SOURCE HEAT PUMP OUTDOOR UNITS STACK-
MOUNTED ON GALVANIZED STEEL FRAME ON
CONCRETE PAD ON MILDLY COMPACTED GRADE
ELECTRIC GFI EXT.
RECEPTACLE
ELECTRIC SERVICE
PANEL AND METER
BOARD 4'W X 3'H —
SUFFICIENT SPACE FOR
PV INVERTER
CONCRETE; EXPOSED
CORNER BOARD —
5/4 X 6 VINYL
4X4 POST CASED
IN 1 X .. WOOD;
(TYP. OF 2)
DECK WITH EDGE BOARD
HOSE BIB AT 18"
ABOVE GRADE
D A
A
ASPHALT SHINGLE
ROOF COVERING
WINDOW SCHEDULE
MARK
A
B
B
C
D
E
F
QUANTITY
13
1
4
3
2
2
1
MANUFACTURER MODEL NO.SIZE ( WIDTH X HEIGHT)
3'-0"x5'-0"
2'-6"x2'-6"
5'-0"x5'-0"
2'-6"x4'-0"
2'-0"x3'-6"
2'-6"x5'-0"
2'-6"x3'-8"
AREA
15.00
6.41
25.00
10.00
7.00
12.50
9.17
TYPE REMARKS
2017%01%01&&
&
A3 Elevs Dwg Notes.docx&
&
{Note: When PDF’ing - use custom paper size 5”x36”}&
&
&
&
EXTERIOR ELEVATION NOTES
1.All dimensions are to face of framing, top of sub-floor, or top or face of
concrete unless otherwise noted.
2.Mounting Blocks in plane of siding for power outlet, hose bib,
ventilation duct, lighting fixture or similar penetrations shall of the same
material and material thickness as exterior trim material — 5/4
Mounting blocks shall be canted at the top edge and have a top flashing
— formed aluminum in color to match siding or trim.
&
SCALE: 3/16" = 1'-0"
NORTH ELEVATION
SCALE: 3/16" = 1'-0"
SOUTH ELEVATION SCALE: 3/16" = 1'-0"
EAST ELEVATION
SCALE: 3/16" = 1'-0"
WEST ELEVATION
SCALE: 1' = 1'-0"
WINDOW SCHEDULE 01
A3.1
F.C. 2ND FLR
649' -0"
T.O. FOOTING
625' -0"
F.F 2ND FLR
641' -0 1/8"
F.F 1ST FLR
632' -0"
C1
A3.1
1 32
A1
A3.1
A
C A
A
BOARD AND BATTEN PINE SIDING, 1'-0" O.C.
BATTEN SPACING, STAINED
DECK RAILING, 4X4 PT POSTS WITH 1X1
PT PICKETS AND 2X PT HORIZONTALS
HOSE BIB, TYP.
EGRESS EGRESS
TWO AIR SOURCE HEAT PUMP
OUTDOOR UNITS STACK-
MOUNTED ON GALVANIZED
STEEL FRAME ON CONCRETE
PAD ON MILDLY COMPACTED
GRAVEL.
EXTERIOR OUTLET WITH
WEATHER-PROOF ENCLOSURE,
TYP.
1' - 0"
F.C. 2ND FLR
649' -0"
T.O. FOOTING
625' -0"
F.F 2ND FLR
641' -0 1/8"
F.F 1ST FLR
632' -0"
A3
A3.1
C3
A3.1
ADBCE
A
D
D
A.1MIN
8' - 0"
FRESH AIR SUPPLY INTAKE GRILLE ON
MOUNTING BLOCK
EXHAUST AIR GRILLE ON
MOUNTING BLOCK
RANGE HOOD GRILLE ON
MOUNTING BLOCK
EGRESS EGRESS
KITCHEN WINDOWS
6'-6" HEAD HEIGHT,
TYP.
TWO AIR SOURCE HEAT PUMP
OUTDOOR UNITS STACK-
MOUNTED ON GALVANIZED STEEL
FRAME ON CONCRETE PAD ON
MILDLY COMPACTED GRAVEL.
F.C. 2ND FLR
649' -0"
F.F 2ND FLR
641' -0 1/8"
F.F 1ST FLR
632' -0"
A3
A3.1
C3
A3.1
A DBC E
PV ARRAY FOR SCHEMATIC
PURPOSES ONLY, FINAL LAYOUT AND
DETAILS BY PV INSTALLER
ASPHALT SHINGLE ROOFING
VINYL SIDING, 4" EXPOSURE, TYP.
CORNER BOARD 5/4X4 VINYL, TYP.
EXPOSED CONCRETE
ENTRY ROOF, WITH EXPOSED WOOD
BRACKETS
CONTINUOUS GUTTER WITH INTEGRAL
DOWNSPOUTS, TYP.
WINDOW TRIM 5/4X4, VINYL, TYP.
A
B B
A
D1 HOSE BIB, TYP. EXTERIOR OUTLET WITH WEATHER-
PROOF ENCLOSURE, TYP.
EGRESS EGRESS
RADON RELIEF PIPE AND PLUMBING
STACK VENTS TO BE LOCATED ON
NORTH FACING ROOF PANEL,
COORDINATE WITH ROOF FRAMING,
TYP.
TEMPERED4"F.C. 2ND FLR
649' -0"
F.F 2ND FLR
641' -0 1/8"
T.O. FOUNDATION
631' -0"
F.F 1ST FLR
632' -0"7' - 11 7/8"9' - 0 1/8"17' - 0"C1
A3.1
132
A1
A3.1
A
A
D
EXTERIOR FLOOD LIGHT
EGRESS
KITCHEN WINDOWS 6'-6"
HEAD HEIGHT, TYP.
ELECTRIC SERVICE ENTRY
AND METER PANEL ON 4X4
MOUNTING BOARD WITH
SPACE FOR PV INVERTER
AND ELECTRICAL VEHICLE
CHARGING 4' - 0"4' - 0"V.I.F.KUHN RIDDLE
A R C H I T E C T S
28 AMITY ST. SUITE 2B
A M H E R S T
MASSACHUSETTS 01002
4 1 3 2 5 9 1 6 3 0
www . kuhnriddle . com A
C
1 2 3 4 5
1 2 3 4 5
A
D
B
C
c Kuhn Riddle Architects, Inc.T
Date:
Drawn By:
Project:
Scale:3/4/2022 2:33:44 PM1/4" = 1'-0"
03.04.2022
CWR
EXTERIOR ELEVATIONS
Concept Plan solar ready roof
Habitat for Humanity Conway
P21181/4" = 1'-0"
WEST EXTERIOR ELEVATIONB31/4" = 1'-0"
NORTH EXTERIOR ELEVATIONB1
1/4" = 1'-0"
SOUTH EXTERIOR ELEVATIONA31/4" = 1'-0"
EAST EXTERIOR ELEVATIONA1