Loading...
32A-242 (4) SM-2022-0011 127 BRIDGE ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 32A-242-001 CITY OF NORTHAMPTON Permit: Sheet Metal PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # SM-2022-001 1 PERMISSION IS HEREBY GRANTED TO: Project# INTERIOR RENOVATION Contractor: License: Est. Cost: 30743 AARON MORIN SHEET METAL Const.Class: Exp.Date: Use Group: Owner: AMY CAMPBELL. Lot Size (sq.ft.) Zoning: SC/URC Applicant: AARON MORIN SHEET METAL Applicant Address Phone: Insurance: 140 WEST ST 413-427-1416 WCT1090D WEST HATFIELD, MA 01088 ISSUED ON:04/28/2022 TO PERFORM THE FOLLO WING WORK: HVAC POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: i i I (T-f 0 • if I Fees Paid: $25.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Buildine Commissioner RECEIV L) Commonwealth of Massachusetts APR 2 7 202�. f `I Sheet Metal Permit DEPT.OF BUILDING INSPEG C 'S �)_ 3.2/1 -- yZ NORTHAMP1 1A 010 Permit#50I- a a- Ii Estimated Job Cost: $ 30 7{3 00 Permit Fee: $ 2,6 GK'*-4-6 Coo Plans Submitted: YES (, NO Plans Reviewed: YES NO Business License# S---33 Applicant License# Business Info tion: 1 [, Property Owner/Job Locationati Information: ����-SLe e ►r^IName: / �/ C7k- i be / Name: / Street: NO (,,e 57 5 Street: /27 1Sn" `4 j e-- Sie-T_ City/Town: W-s t �j4q,4P� d City/Town: A-C11"—A-en'9,71*." Telephone: q(3 --I ?7 i"/(l„ Telephone: Photo I.D. required/Copyof Photo I.D. attached: YES NO Staff Initial J-1 1-1- estricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional ther Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories: 2 Sheet metal work to be pleted: New Work: (/ Renovation: HVAC [ Metal Watershed Roofing_ Kitchen Exhaust System Metal Chimney/Vents Air Balancing v5( Provide detailed description of work to be done: ( c ( ( lx q ' 60 Coo 6YW as .e_ oZ ,./) ie/A- &A l'co-e-c- (APto 90.5rie) cal de�.ser- LAP.- /4 srte0 i, ' '15-f,k,l( a_ Dutt,-re, Soins,,,ili At,.iii i.- 5,C-f- doe s-sr6W colts a_i\r-iNc444. --6Le.g can d.ed..3,_e_f--- . #(50 cx_ 5-0 AN- kud“-c-- (/. iidc,, de ( ( - -- /4-6c e dt ric_ Ji s u.00...iect J. Set ._(ed to co d-e__ . INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy El "t Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent El Signature of Owner or Owner's Agent By checking this boxfl,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of Lice . By aster Title ❑ Master-Restricted City/Town ❑Joumeyperson Signature of Licensee Permit# ❑Joumeyperson-Restricted License Number: 537 Fee$ ❑ Check at www.mass.gov/dpl / TZ6Z022 Inspector Signature of Permit Approval g'COMMONW 'LTH OF MA CHUSETTS DIVISION OF PROFESSIONAL LICENSURE BOARD OF MASSACHUSETTS DRIVER'S SHEET METAL WORKERS LICENSE ISSUES THE FOLLOWING LICENSE W NOT FOR FEDERAL ID CC f Z. ISS 4 UUMBER MASTER-UNRESTRICTED D 1v03/2020 S19852961 a AARON S MORIN ioi1412025 10114/1971 w ` CLASS REST END NONE 140 WEST ST i W WEST HATFIELD, MA 01088-9500 ti;' ^.._; W AARON SCOTT 0 ,. "a 140 WEST ST d-, WEST HATFIELD,MA 01088-9500 533 10/28/2023 121298 eras HAL LICENSE NUMBER EXPIRATION.DATE SERIAL NUMBER _ sEx M ecr 5'-11" 1 0/1 417., _OD 1110 42 0 2 0 Rev 02I22R016 0-7 6c,' dg ,5 ( F T /51—R.c.r----- ----"'"//04„---' ..„.„ I 0 0 e H { 99 — ..o , I b^ W 1 I I►I . ---- r 4 L�,�j�(k7 4173 � I I q I I 1 I 146 I. A' « C---- � .y� rr T-, ^--f-'T L Y1Crir -T (17-0" 6004'• 93v re ... .B M I 1/Y�i 0 Cr- iir I 'T I TI CLOSET cl Ill ' HALF r--- . 1 7 _- .�� / 1 �� r' 11 21 j/yQd BATE 1 *2a7-o• I I �"r' ' `' ' I ,, 'r �,-,A,� q I 3'X 5'4• , l/G „0' , , %wEA ' I_1 ® I ' (2)2 t - j-'kr. L \ Vy - iJ .+C1 „DOOR PANELS r°cr °. sr sirr /�\ /.4titibl �. a t�DA4D SFELFAND tf2 e ' • or \ 11 lh i 1/4. u gLAND S sEL ANO • a� ^.. ,� �r�:`� \ �i"oti.w t11ao Hook UPS A i*. +a CLOSE. _ ) Oki_ .dp a SHELF !r k j-4." ,iNCI ,iii•1 ,._,ill 1114r _1/45...>,1,..._,..44t1\ 41% , S,I I D OI 6 t° 3"r,l 1a-t• ,Invi ___f ` 0 l' -z."W-2" i' W-117 . PAPITINV COMETS Itn---'-'-'' la's ail RAISE SW OFE JO 71/ UP W DO,NS TO MAX 4tSTWO'AFF 9:10C�/Sp cb ® I - 1_1_40,„, ef.i --N.,- ` to o• 13 e 7-2" I, W-47 (j �.o• 3•4• 7-a= srlEr lr a a°° -, 1( 0 -4 N .. 17 am ID ~ I 0 \ p O a-. I' f 0 ©�� 00 s 0 Yip.X��k -- — "—L— /. tIts L. 3-SEASON PORCH ® , 6S �» ej � I1�1:i►•M°° —_""_ r s r I \ I \ I z0I *12'-6 V2' s a' ` H 6 a e.�cn dfIo I SUM d win .. 11T ® r 1 l` 4 _L �1 • i /� /� NEW RO.TO MEET 1 (�7 n`�c)�\ I EGRESS CODE GC TO �� 4 / Vh Il\?`I J CONFIRM IF RAISING /' EXSITING HEADER IS / POSSIBLE_ ' • 9'-0 112' ,' • • g' 4°° . • BEDROOM 3 1�,� tit V y 5 �® f, TILE READY SHOWER SYSTEM �', a ER f EIESS SHOTNER e :OOR . 0 �' •EE f18,A-401 FOR INTERIOR" s•-r r EVATIONS 1111 0 ►'j:ATH ‘�� � 1-6" I t -6 _4,_5:._: 1-. 4 • .. , . .„ „ _ a ' , „ b /! ,\ IHAU,,, 9 3'-� , \ 4) BEDROOM 4 ' • . m 11: / 9 11►� t yX9 (5 3S ,/ I VIM 'r; c( I1iii2'S 0 3!4'/ \ // •; 3'-0" IN ��r � mil ' e) 10 " LO N eta - II i,,, -: I IF1Te//1 I.-i■.L1I! r4 'lir sHELVEsdila f, MTI► ® LOSET I/ IV _ .36'f, I ' I a' 4 /, (, r' INFILL FLOOR AT LOCATION OF ® 'i REMOVED CHIMNEY AND STAIRCASE 13 ill ALL NEW KNEE WALLS 1 ` i �I W CENTER DOOR I I I a RIDGE BEAM TO BE SIZED BY I E4 LUMBERYARD.STUD 1 1 I EXTEND STUDY IN NEW REAR I I -BLED DORMER trs I T i 1 1 C ai1 un a !. Load Short Form Job: RT-9528 441- wrightsoft Date: Apr 21,2022 Entire House By: Jeff ASM SHEETMETAL Project Information For: Residence at 127 Bridge St Northampton, MA Design Information Htg Clg Infiltration Outside db (°F) -2 85 Method Simplified Inside db(°F) 72 71 Construction quality Semi-tight Design TD (°F) 74 14 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (grill)) 31 36 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 2nd FL SYSTEM 773 17003 8546 527 527 1ST FL SYSTEM 1677 56942 27614 1000 1000 Entire House 2450 73944 36159 1527 1527 Other equip loads 0 0 Equip. @ 0.90 RSM 32543 Latent cooling 2328 TOTALS 1 2450 I 73944 I 34872 I 1527 I 1527 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Apr-21 11:56:10 AC -Pk wrightsoft Right-Suite®Universal 2017 17.0.28 RSU18116 Page 1 ..\Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJ8 Front Door faces: W 9 Load Short Form Job: RT-9528 wrightsoft Date: Apr 21,2022 1ST FL SYSTEM By: Jeff ASM SHEETMETAL Project Information For: Residence at 127 Bridge St Northampton, MA Design Information Htg Clg Infiltration Outside db (°F) -2 85 Method Simplified Inside db(°F) 72 71 Construction quality Semi-tight Design TD (°F) 74 14 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/lb) 31 36 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Generic Trade Trade Model Cond AHRI ref 8412957 Coil AHRI ref Efficiency 96.5 AFUE Efficiency 12.8 EER, 15 SEER Heating input 46810 Btuh Sensible cooling 16800 Btuh Heating output 46810 Btuh Latent cooling 7200 Btuh Temperature rise 43 °F Total cooling 24000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.036 cfm/Btuh Static pressure 0.35 in H2O Static pressure 0.35 in H2O Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) LIVING 335 13100 5991 230 217 DINING 350 8308 4512 146 153 Kitchen 407 13161 5166 231 187 MASTER SUITE 440 14635 7973 257 289 Bed 2 145 7737 3971 136 124 1ST FL SYSTEM 1677 56942 27614 1000 1000 Other equip loads 0 0 Equip. @ 0.90 RSM 24852 Latent cooling 1463 TOTALS i 1677 l 56942 I 26316 I 1000 I 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Apr-21 11:56:10 i4Cwrightsoft Right-Suite®Universal 2017 17.0.28 RSU18116 Paget ...\Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJ8 Front Door faces: W 28 - + wrightsoft Load Short Form Da e: Apr 12,2022 2nd FL SYSTEM By: Jeff ASM SHEETMETAL Project Information For: Residence at 127 Bridge St Northampton, MA Design Information Htg Clg Infiltration Outside db(°F) -2 85 Method Simplified Inside db(°F) 72 71 Construction quality Semi-tight Design TD (°F) 74 14 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/lb) 31 36 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 96.5 AFUE Efficiency 18 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 527 cfm Actual air flow 527 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.062 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Hall 369 6141 3263 190 201 Bed 4 105 2925 2683 91 165 Bath 40 599 126 40 40 Study 169 4217 1639 131 101 Bed 3 90 3122 834 97 81 - 2nd FL SYSTEM 773 17003 8546 527 527 Other equip loads 0 0 Equip. @ 0.90 RSM 7691 Latent cooling 865 TOTALS I 773 I 17003 I 8556 I 527 I 527 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Apr-21 11:56:10 A wrightsoft Right-Suite®Universal 2017 17.0.28 RSU18116 Page 3 AC CA ...\Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJB Front Door faces: W 41- wrightsoft Building Analysis sis Job: RT-9528 Date: Apr 21,2022 Entire House By: Jeff ASM SHEETMETAL Pro'ect Information For: Residence at 127 Bridge St Northampton, MA Desi• n Conditions Location: Indoor: Heating Cooling Greenfield (Worcester Dd), MA, US Indoor temperature(°F) 72 71 Elevation: 250 ft Design TD (°F) 74 14 Latitude: 42°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 31.3 35.8 Dry bulb(°F) -2 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified V1ibt bulb(°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 4.9 12091 16.4 V1�11 infiltration Glazing 42.2 14658 19.8 Doors 21.5 451 0.6 Ceilings 13.2 22554 30.5 Roots Floors 8.2 14028 19.0 Gazing_ Infiltration 2.7 7694 10.4 Ducts 2469 3.3 Piping 0 0 Cther Humidification 0 0 Ceilings Ventilation 0 0 Adjustments 0 Total 73944 100.0 Coolin• Component Btu h/ft2 Btuh %of load , Walls 1.0 2499 6.9 V�II Infilfption Glazing 41.7 14498 40.1 oor5 Doors 7.4 155 0.4 Ceilings 8.7 14934 41.3 Floors 1.6 2654 7.3 Infiltration 0.3 780 2.2 Ducts 639 1.8 Gazing-_ Ventilation 0 0 Ceilings Internal gains 0 0 Blower 0 0 Adjustments 0 Cther Total 36159 100.0 Latent Cooling Load=2328 Btuh Overall U-value=0.188 Btuh/ft2-°F Data entries checked. 2022-Apr-21 11:56:10 AC.-_ " wrightsoft. Right-Suite®Universal 2017 17.0.28 RSU18116 Page 1 ..\Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJ8 Front Door faces: W BuildingAnalysis Job: RT-9528 - wrightsoftna Date: Apr 21,2022 1ST FL SYSTEM By: Jeff ASM SHEETMETAL Pro'ect Information For: Residence at 127 Bridge St Northampton, MA Desi• n Conditions Location: Indoor: Heating Cooling Greenfield (Worcester Dd), MA, US Indoor temperature(°F) 72 71 Elevation: 250 ft Design TD (°F) 74 14 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 31.3 35.8 Dry bulb(°F) -2 85 Infiltration: Daily range (°F) - 20 ( M ) Method Simplified ' At bulb(°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 4.8 6369 11.2 WiI infiltration Glazing 42.2 9305 16.3 Doors 21.5 451 0.8 a� Ceilings 22.5 21066 37.0 Rppg Floors 8.2 13752 24.2 Infiltration 2.7 4257 7.5 Cther Ducts 1742 3.1 Piping 0 0 Humidification 0 0 Ceilings Ventilation 0 0 Adjustments 0 Total 56942 100.0 Coolin• Component Btu h/ft2 Btuh %of load Walls 0.9 1231 4.5 Wall Floors Glazing 39.9 8792 31.8 Doors 7.4 155 0.6 Ceilings 14.9 13949 50.5 aazl Floors 1.6 2602 9.4 Infiltration 0.3 431 1.6 Ducts 454 1.6 Ventilation 0 0 Internal gains 0 0 Ceilings Blower 0 0 Cthe Adjustments 0 Total 27614 100.0 Latent Cooling Load = 1463 Btuh Overall U-value=0.239 Btuh/ft2-°F Data entries checked. 2022-Apr-21 11:56:10 .lA - wrightsoft Right-Suite®Universal 2017 17.0.28 RSU18116 Paget ..\Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJ8 Front Door faces: W 41- wrightsoft Building Analysis Job: RT-9528 Date: Apr 21,2022 2nd FL SYSTEM By: Jeff ASM SHEETMETAL Pro'ect Information For: Residence at 127 Bridge St Northampton, MA Desi• n Conditions Location: Indoor: Heating Cooling Greenfield (Worcester Dd), MA, US Indoor temperature (°F) 72 71 Elevation: 250 ft Design TD (°F) 74 14 Latitude: 42°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 31.3 35.8 Dry bulb(°F) -2 85 Infiltration: Daily range (°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh % of load Walls 5.0 5722 33.7 axis Glazing 42.2 5353 31.5 Infiltration Doors 0 0 0 \A is fr Ceilings 1.9 1488 8.8 Floors 8.2 277 1.6 Cther Infiltration 2.7 3437 20.2 Ducts 727 4.3 Ceilings Piping 0 0 Humidification 0 0 Glazing 0 0 Adjustments 0 Total 17003 100.0 Coolin• Component Btu h/ft2 Btuh % of load Walls 1.1 1268 14.8 ' Ir7t)I, ation Glazing 45.0 5706 66.8 \Adis u Doors 0 0 0 Clings Ceilings 1.3 985 11.5 Floors 1.6 52 0.6 Infiltration 0.3 348 4.1 Ducts 186 2.2 Ventilation 0 0 *1110 Internal gains 0 0 Blower 0 0 Adjustments 0 Gang Total 8546 100.0 Latent Cooling Load = 865 Btuh Overall U-value =0.087 Btuh/ft2-°F Data entries checked. 2022-Apr-21 11:56:10 wrightsoft Right-Suite®Universal 2017 17.0.28 RSU18116 Page 3 AC OI° \Wrightsoft HVAC\Residence at 127 Bridge ST.rup Calc=MJ8 Front Door faces W TAG: eC 10 Alik SUBMITTAL Product Specifications OUTDOOR UNIT EODA18H-2436 Up to 3 Ton Inverter Split Voltage-Phase-Hz 208/230-1-60 System Heat Pump Minimum Circuit Ampacity 24.4 Max.Over-current Protection 40 COMPRESSOR Variable rotary RLA 17.5 LRA 45 Drive Method Inverter Noise-cancelling Jacket Factory installed Crankcase Heater Internal heating OUTDOOR FAN Propeller W Condenser Fan Motor Type Brushless DC Motor f . �i �1 .�/ �,� � Horse Power(HP) 1/3 l i Motor Speed RPM 930 . �� S �; CFM @ 0 in. W.G 3735 --� ' 0; FLA 2.5 H � ��� OUTDOOR COIL TYPE Copper tube with hydrophilic aluminum fins � Dt Rows 2 d� '�00 Tube Size(in.) 9/32 o� _. .,�— D Heating Metering Device EEV Cooling Metering Device TXV (Indoor side) Factory Supplied Refrigerant Data on nameplate Charge(R-410A, oz) Superheat at Service Valve 8°F (±2°F) Sub-cooling at Service Valve 10°F (±2°F) Liquid Line Size(in. O.D.) 3/8 Suction Line Size(in. O.D.) 3/4 Dimensions 29-1/8 x 24-15/16 x 29-1/8 Sound pressure level (dB) (w X H X D) EODAI8H-2436 2Ton* 3Ton Net Weight(LBS) 157 Standard 63 66 Shipping Weight(LBS) 187 Silent mode 59 63 Max. Line Length(FT) 100 Super silent mode 56 60 Max. Elevation Difference(FT) 50 *Refer to the installation manual for capacity selection. Manufacturer reserves the right to change specifications or designs without notice. 04.2020 S111V1 5 U N 5 iUIsMI I I AL AGO24SamsuBg HDD t S Single Zone Duct, Split (CNH24HDB/CXH24ADB) ray',(,v Job Name Location Purchaser Engineer Submitted to Reference EJ Approval 0 Construction n Unit Designation Schedule# Specifications Indoor Unit Model Number(US Code) ACO24BNHDCWAA(CNH24HDB) Model Outdoor Unit Model Number(US Code) ACO24BXADCH/AA(CXH24ADB) ��" Nominal Capacity Coding/Heating(eturtl) 24,000 127,000 Capacity Range Cooling(Btuth) 8,400-32,000 Heating(Btu/h) 7,000-39,000 performance 1 SEER/EER `` COP(nominal heating) 3.3 HSPF 11 AHRI Certification Number 207465455 _ . - - Voltage le/V/Hz 1/208-230/60 General Information Working Voltage Range(VAC) 176-254(max.3%deviation from each) •The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire Power Operating Current Cooling(A) 2.4/8.8/14.2 •High-voltage terminal block temperature sensor to disable unit in the event of (min./std./max.) Heating(A) 2.3/11.0/23.5 power connection overheating Max.Breaker Amps 30 •Integral condensate pump with maximum 29"lift from bottom of the unit with Min.Circuit Ampacity(A) 24.1 check valve and float switch that disables indoor should condensate overflow be detected. W X H X 0 Indoor Unit 47 1/4 X 9 13/16 X 27 9/16 •Auto-restart after power loss (In.) Outdoor Unit 37 X 39 5/16 X 13 •Soft-start compressor minimizing current inrush Dimensions Duct Connections Supply(in.) 45 5/16 X 811/16 •All heat exchangers shall be mechanically bonded aluminum fin to copper tube (W X H) Return(ID,in.) 45 5/16 X 8 11/16 •The condensing unit heat exchanger salt spray test method:ASTM-B117-18-the Weight Indoor Unit 76.1 heat exchanger showed no unusual rust or corrosion development to 2,280 hours. (lbs.) Outdoor Unit 189.8 •Base pan heater equipped as standard Sound Pressure Indoor Unit dB(A) L/M/H 28/32/36 •System shall provide 100%heating capacity at-4°F(-20°C) Level Outdoor Unit dB(A) Cooling/Heating(high) 50/52 Option settings •The outdoor unit shall have snow accumulation prevention option setting to Cooling 23-122°F(-5-50°C) prevent snow drifting against an idle outdoor unit. Outdoor0-122°F(-18-50.C)w/baffle •Night-time Quiet Mode:reduction of operational sound during(automatic or Operating Heating -4-75°F(-20-24°C) manual activation). Temperatures Cooling 61-90°F(16-32°C) •Emergency Temperature Output(ETO)function:when indoor unit is in error status Indoor ,Heating T s 80°F(27°C) or when room temperature exceeds configurable temperature level,the system High side(flare) 1/4" outputs a signal to an external source,e.g.,backup system,building management Indoor&Outdoorsystem,alert device(ex:status light,warning lamp,buzzer). Low side(flare) 5/8" •System can be set up as heating/cooling,cooling only,or heating only via Pipe Connections Maximum(ft.) 164 outdoor unit option setting. Maximum Vertical Separation(ft.) 98.4 •Maximum Current Control configurable from 50%-100%via outdoor unit, Condensate Connection(with included adapter) 1 1/16"ID for 3/4"PVC wired controller,or central controller Type R410A Indoor Fan Control Method Electronic Expansion Valve •Indoor fan is sirocco type Refrigerant Factory Charge llbs. 5.7 Charged for 24.8 ft •Three fan speed settings and auto setting Additional Refrigerant 0.11 oz/ft over 24.6 ft •Smart pressure control feature that adjusts fan speed based on ESP delivering Manufacturer Samsung consistent heating and cooling power Compressor Type Inverter Driven,Twin BLDC Rotary •The indoor unit shall have a smart-tuning function that can provide optimized RLA 'Amps 15.9 comfort by allowing the occupant to offset the fan CFM curve with a wired remote controller(MWR-WGOOUN)to increase or decrease airflow. Type BLDC(1)With Sirocco Fan(3) •The indoor unit shall have automatic air volume scanning for simple setup and Air Volume ICFM(LIMIH) 593/671/749(at standard ESP) optimized comfort settings for the occupant. Evaporator Fan Output(W)/FLA(A) 153 W/2.10 A Static Pressure Standard("WC) 0.18 Construction Min./Max.("WC) 0.1-0.79 •Outdoor unit shall be galvanized steel with a baked-on powder coated finish Motor BLDC With Axial Type Fan(1) for durability Condenser Fan •Indoor Unit:Insulated,galvanized steel. FLJ1/Watts/CFM(max.) 1.25 A/125 W/2,684 CFM Certifications I ETL(UL 1995) Controls Safety Devices:PCB fuses,indoor mat temrinat block thermal fuse,current transformer,over-voltage •Control wiring shall be 2 X 16 AWG protection,crankcase heating,temperature limit protection logic,compressor overload sensing •No additional interface modules/adapters are required when connecting to 'Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps(USHP)Certification Program Samsung central control options. which is based on the latest edition of AHRI Standard 210/240. •The unit shall be operated via a wireless or wired remote control with DDC type signal Samsung HVAC maintains a policy of ongoing development,specifications are subject to change without •Dual set temperature support when connected to MWR-WGOOUN Advanced notice.Refer to www.AHRldirectory.org for current reference numbers. Wired Controller or central control options. •Wired or wireless controllers must be purchased separately Select models are ENERGY STAR Labeled.Proper sizing and installation of equipment is critical to achieve performance. Split system air conditioners and heat pumps(excluding Refrigerant System ductless systems)must be matched with appropriate coil components to meet ENERGY STAR •The compressor shall be hermetically sealed,inverter-controlled BLDC rotary type. criteria. Ask your contractor for details or visit www.energystar.gov. •Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit Warranty 10 Years compressor, 10 years parts,1 year limited labor when registered ti CERTIFIED.. c (ill us ©2022 Samsung HVAC °nf"�"'''"c NIN,iIBItl.011h:Ip SHA-CAC-02072022 www.SamsungHVAC.com ENERGY STAR ^-t---------- IntPrtPk 5129599-YTG-B-1115 YORK® DESCRIPTION yo R These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized steel tubular primary heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be con- verted for downflow applications. Heating and Air Conditioning These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and TECHNICAL GUIDE are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and 96%AFUE TWO STAGE STANDARD ECM economical installation and operation. RESIDENTIAL GAS FURNACES These units are Category IV listed and may be vented either MULTI-POSITION through side wall or roof applications using approved plastic combustion air and vent piping. MODELS: TM9Y NATURAL GAS FEATURES 40-120 MBH INPUT • Two stage heating operation includes two stage gas valve, two stage inducer operation and constant torque standard ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. toRx • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33"tall cabinet. • Standard ECM constant torque drive for cooling SEER enhancement, improved comfort with optional airflow delay (---.C. profiles,and continuous fan options for IAQ performance. COMPLETE • Easy access to controls to connect power/control wiring. ASSURANCE , lAttrD wAR►A Y Built-in, high level self diagnostics with fault code display. • Low unit current draw requirement for easy replacement • ell.* application.All models are convertible to use propane(LP)gas. poM e • Electronic Hot Surface Ignition saves fuel use with increased dependability and reliability. • 100%shut off main gas valve for extra safety. • 24V,40 VA control transformer and integrated furnace con- trol supplied for add-on cooling. EfousekeePing ;t"\ • Hi-tech tubular aluminized steel primary heat exchanger A. CERTIFIED,. /\ with stainless steel tube/aluminum fin secondary heat """'""°"""°' °'° �,Q I exchanger for outstanding efficiency. Needen"al furnaces 00E 10 CFfl Pert 430 460 �� • Solid removable bottom panel allows easy conversion. El • Airflow leakage less than 1% of nominal airflow for duct blaster conditions. .06. f'9° REctsO" • No knockouts to deal with, making installation easier. ISO 9001 • Movable duct connector flangesfor application flexibility. ENERGY STAR Certified Quality Management System • Quiet inducer operation, burner,and blower operation. Due to continuous product improvement,specifications are • Inducer rotates for easy conversion of venting options. subject to change without notice. Visit us on the web at www.york.com • Fully supported blower assembly for easy access and removal of blower. Additional rating information can be found at • External air filters used for maximum flexibility in meeting www.ahridirectory.orq customers IAQ needs. WARRANTY SUMMARY • Insulated blower compartment for thermal and acoustic per- formance. A 20-year limited warranty on heat exchangers in resider- • 1/4 turn knobs provided for easy independent door removal. tial applications. A 10-year warranty on the heat exchanger in commercial • Internal condensate trap design (patent pending) provides applications. condensate management options and is self priming to pre- Standard 5-year limited Parts warranty. vent nuisance problems. Extended lifetime heat exchanger and 10-year limited • Protection included from air intake,exhaust vent or conden- parts warranty when product is registered online within sate blockage. 90 days of purchase for replacement or closing for new • Venting applications maybe installed as either 2 pipe sealed home construction. combustion or single pipe vent using indoor combustion air. See Limited Warranty certificate in Users Information Manual for details. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 5129599-YTG-B-1115 LEFT SIDE FRONT RIGHT SIDE Combustion Air Inlet Combustion Air Inlet • Condensate Drain / • Gas Pipe (Downflow) Entry Gas Pipe Condensate Drain Entry ��roo (Downflow) Vent Outlet Electrical i p�—Entry Electrical---...� Condensate o Entry Vent Outlet • o�Drain m m 1 33 Condensate--g.►0 • 23"—_jI r 1 _ m ID Drain r Thermostat In1 1nI Wiring Thermostat O tional Retumlir Wiring p 1I I Cutoutl (Eitherll side) li J• --rP r 1 q-.,� U Y Y 4" lir 28.5" ►I� 1�---A—'I 1.5""� 29.5" .56 I4 23.8" 3" TI r Vent ;\ �'I Outlet d , B Combustion I r B Air Inlet • IC _i___ .56" 56" 20" 24.25" 1 SUPPLY END RETURN END Cabinet&Duct Dimensions Nominal Cabinet Cabinet Dimensions(Inches) Approximate Model Operating Weights CFM(m3/min) Size A B C Lbs TM9Y040A10MP11 1000 A 14-1/2 13-3/8 11-3/4 113 TM9Y060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 119 TM9Y080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 123 TM9Y080C16MP11 1600 C 21 19-7/8 16-1/2 130 TM9Y100C16MP11 1600 C 21 19-7/8 18-1/4 136 TM9Y100C2OMP11 2000 C 21 19-7/8 18-1/4 143 TM9Y120D2OMP11 2000 D 24-1/2 23-3/8 21-3/4 154 Ratings&Physical/Electrical Data Input Output Total AFUE High Fire Low Fire Model High/Low High/Low Unit Air Temp.Rise Air Temp.Rise MBH MBH Amps % °F °F TM9Y040A10MP11 40/26 38/25 9.5 96 25-55 25-55 TM9Y060B12MP11 60/39 58/37 9.5 96 35-65 35-65 TM9Y080B12MP11 80/52 77/50 9.5 96 45-75 35-65 TM9Y080C16MP11 80/52 77/50 9.5 96 40-70 25-55 TM9Y100C16MP11 100/65 96/62 9.5 96 50-80 30-60 TM9Y100C20MP11 100/65 96/62 10.9 96 45-75 30-60 TM9Y120D20MP11 120/78 115/75 10.9 96 50-80 45-75 Max.Outlet Blower Blower Size Max. Min.Wire Size Model Air Temp. Over-current (awg)@ 75 ft. °F HP Amps In. Protect One Way TM9Y040A10MP11 190 1/2 6.8 11 X 8 15 14 TM9Y060B12MP11 190 1/2 6.8 11 x 8 15 14 TM9Y080B12MP11 190 1/2 6.8 11 x 8 15 14 TM9Y080C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C20MP11 190 3/4 8.4 11 x 11 15 14 TM9Y120D20MP11 190 3/4 8.4 11 x 11 15 14 Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products Iiiiiiii. : MODEL TRLPe100 (Energy Recovery Ventilators (ERV)) ® 2'100 ., ...IR7 4. l 1 CERTIFIED a us '` NTE .'/ " 'n. LISTED DUCTED HEAT +.• 6 RECOVERY VENTILATOR �,;.+'' 89S5 ��`' .'' .r_ yY Specifications Ecewatt® _ � .* Ventilation Type: Static Plate,Heat and Humidity Transfer Typical Airflow Range:30-110 CFM ul __�. ,� , suuui~umuosua. o Painted Case, No Line Cord Core Performance Unit may be mounted in any orientation and in heated or unheated locations Airflow (CFM) Number Motors:2,48V EC motorized impeller packages 30 60 90 120 0 V Hz Phase Max Watts FLA per �100% motor u i 80% Sensible 120 60 Single 104 2 0) Control Voltage:24 VA (7) 60% - Winter Total Filters:MERV 8,spun polyester media.7-1/2"x 10-1/2"x 1" U 40% - Summer Total -- Weight:32 lbs(unit),38 lbs(in carton) 20% - Shipping Dimensions:29-1/2"L x 22-1/2"W x 11-1/2"H W At AHRI 1060 standard conditions.See all AHRI certified ratings at www.ahrinet.org. EC Operating Range Sample Points Depicted in Larger Dots 1.20 External Static Unit Power Airflow(CFM) Pressure Consumption (Inches Water (Watts) Column) 82 0.1 62 1.00 77 0.2 60 i72 0.3 59 0 67 0.4 58 • • 0.80 61 0.5 56 3 54 0.6 54 c BOOST 45 0.7 51 E MODE 34 0.8 47 1' 0.60 i 0. 108 0.1 104 u u F j 102 0.2 102 '.° rn 95 0.3 100 m I 91 0.4 99 E 0.40 CONTIN OUS 89 0.5 97 "' MO E I 5 SNeM 85 0.6 96 1 81 0.7 94 0.20 1 f 76 0.8 92 1 70 0.9 89 61 1.0 85 0.00 1_ Note: Watts is for the entire unit. 30 40 50 60 70 80 90 100 110 Note: Airflow performance includes effect of clean,standard filter supplied with unit. All specifications are subject to change without notice unless approved in submittal by S&P. TRLPe100_v.1 /03.2019 Soler`1 MODEL TRLPe100 1/4;....811-lh (Energy Recovery Ventilators (ERV)) ABBREVIATIONS EA:EXHAUST AIR TO OUTSIDE OA:OUTSIDE AIR INTAKE 27 1/4"OVERALL RA:ROOM AIR TO BE EXHAUSTED 4 3/8" SA:SUPPLY AIR TO INSIDE 2 1/4"TYP. 22 7/8"CASE I TYP. • • • j INSTALLATION ORIENTATION UNIT MAY BE INSTALLED IN ANY — • • ORIENTATION. NOTE OOO A_ • v Y • 1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS —"—`tp DO ARE ROUNDED TO THE NEAREST 1/8". 2.SPECIFICATIONS MAY BE SUBJECT TO CHANGE POWER OUTLET BOX WITHOUT NOTICE. WITH 3'OF FLEXIBLE CONDUIT 3.MINIMUM SERVICE AREA.DOOR CAN BE 0 7/8"KNOCKOUTS REMOVED FROM HINGES. TOP VIEW 08"NOMINAL TYP. 4 1/8" 06"NOMINAL TYP. TYP. p .^. p ��� . EA II • ;, + ' SA •22"-23" ,, • .� _ ,�y•,4, :, 10 3/4" OVERALL 19" a 20 3/8" ���` '% TYP. (CEILING CASE OVERALL BRACKETS) �� OA Ii . „,•,`X I/ , RA PRESSURE PORTS 4 1/8" (4)TYP. TYP. CONTROL TERMINALS FRONT VIEW LEFT VIEW (HARD MOUNT DEPICTED) 75/8" (SEE NOTE 3) 9 1/2"11 1. OVERALL 18 5/8" 9 1/8" I , CASE 1 tj % DOOR � SWING 21 1/4" 19 7/8" . OVERALL (SEE NOTE 3,\ (HANGING BRACKETS) cHoi.) • Le 2 1/8" MINIMUM LATCH CLEARANCE RIGHT VIEW (HANGING MOUNT DEPICTED) All specifications are subject to change without notice unless approved in submittal by S&P. sder&` TRLPe100_v.1 /03.2019 The Commonwealth of Massachusetts Department of Industrial Accidents z — Office of Investigations =R . Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/organization/individual): Aaron Morin Sheet Metal Address: 140 West Street City/State/Zip:West Hatfield, MA. 01088 Phone#:413-427-1416 Are you an employer? Check the appropriate box: Type of project(required): 1.12 I am a employer with Y 3 4. 0 I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑Ne construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition workingfor me in anycapacity. employees and have workers' P t3' 9. ❑Building addition [No workers' comp. insurance comp.insurance.: required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof insurance required.] t c. 152, §1(4),and we have no � �v� employees. [No workers' 13. er comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. ;Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: National Grange Mutual Insurance Policy#or Self-ins.Lic.#:WCT1090D Expiration Date: 1/19/23 Job Site Address: l 7 eCJ R SfY.e-fi City/State/Zip:/0 f 0*-0 I",61 `l,*d-a(.0-6 O Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA insurance coverage verification. I do herehy certify un r the pain nd penalties of perjury that the information provided above is true and correct. Si ature: Date: Phone#: 413-427-1416 Official use only. Do not write in this area,to be completed by city or town officiaL City or Town: Permit/License# Issuing Authority(check one): 10Board of Health 20 Building Department 31:City/Town Clerk 4.0 Electrical Inspector 5alumbing Inspector 6.DOther Contact Person: Phone#: