1-22_WORKING DRAWINGS - Sheet - A-2 - 1ST & 2ND FLOOR FL PLANSGFI
GFI
GFI
GFI
EXISTING STRUCTURE
TO REMAIN AND BE
REPAIRED WHERE
REQUIRED FOR STABILITY
SECOND FLOOR STRUCTURE
TO REMAIN W/FLOOR BOARDS
REMOVED IN SHADED AREA
A-43
3
A-5
7
A-6
5
A-6
2
A-5
1
A-5
1
A-6
A-3
A-3
2
3
EXISTING BARN - TO
BECOME A MULTI-PURPOSE
& EXHIBIT SPACE
2
A-2.6
PORTION OF ORIGINAL STALL
TO BE MOVED AGAINST THIS
WALL FOR DISPLAY
PREP
AREA
GENDER
NEUTRAL
WC
wh3' - 6"GENDER
NEUTRAL
WC
EXISTING STRUCTURE TO REMAIN - TYP, -
FOLLOW STRUCTURAL DRAWINGS FOR ALL
STRUCTURAL REPAIRS
DASHED LINE INDICATES
BALCONY STRUCTURE ABOVE
EXISTING BARN DOORS TO BE RE-BUILT TO
MATCH ORIGINAL
LEFT DOOR MUST HAVE A 180 DEGREE
SWING - BOTH DOORS MUST BE ABLE TO
FIX IN THE OPEN POSITION FOR EVENTS
GREEN
ROOM
A-2.6
1
A-2.5
1
A-2.5
2
5 A-2.59
6
73
A-2.6
8
9 7
A-2.6 -
4
A-2.6 5
STORAGE
ROOM
4 8
3
6
-
EXISTING DOOR TO BE RE-BUILT TO MATCH
ORIGINAL - DOOR MUST BE ABLE TO FIX IN
THE OPEN POSITION FOR EVENTS
GALVANIZED DOWNSPOUT TO HOOK INTO
NEW DRAINAGE SYSTEM
GALVANIZED DOWNSPOUT TO HOOK INTO
NEW DRAINAGE SYSTEM
EXISTING DOOR TO BE
REPAIRED AS REQUIRED -
DOOR MUST BE ABLE TO FIX
IN THE OPEN POSITION FOR
EVENTS
2 1/2" - 3" BLUSTONE PAD SET
ON6-8" CONPACTED CRUSHED
STONE
4' - 0"V.I.V.4' - 4"NEW LOCKABLE POCKET DOOR W/ADA
COMPATIBLE HARDWARE
NEW STONE PATIO
"BIG ASS" FAN WHERE
INDICATED - SEE SECTION FOR
HEIGHT
NEW 6" X 1 3/8" THICK HEMLOCK FLOORING
SET ON 2 X 4 COMPOSITE SLEEPERS
SPACED 2'- 2'-6" OC
SET ON 6-8" COMPACTED STONE
SET ON A 10 MIL VAPOR BARRIER
TREAT ALL WOOD SURFACES PRIOR TO
INSTALLATION W/BORIC ACID & OIL
SEALANT
BARN AND "L" BUILDING
LENGTH RUNS E/W
DASHED LINE REPRESENTS TIMBER-
FRAME STRUCTURE W/EXTERIOR
SHEATHING AND RE-PURPOSED
HORIZONTAL WOOD SIDING - VARIOUS
WIDTHS TO MATCH THE BARN
ATTACH BLACK-OUT FRIT ON WINDOW
EXISTING BARN DOOR TO BE RE-BUILT TO
MATCH ORIGINAL
POCKET BETWEEN BARN AND NEW ADDITION
TO HOUSE DOOR WHEN OPEN
NEW "ELL" BUILDING
BUILT IN SAME LOCATION
AS EXISTING TO BE
DEMOLISHED
FIN. FL. ELEV. 0'-8" (95.75)
NEW ADDITION
SEE 1/A2.6 FOR ADDITIONAL
"ELL" BUILDING NOTES
6' - 3 3/8"SEE 1/A2.5 FOR ADDITIONAL
BARN ADDITION NOTES
PROVIDE ELECTRICAL
UPGRADE FOR GENERAL
LIGHTING, THEATER LIGHTING,
EXHIBIT LIGHTING, FANS,
EMERGENCY SYSTEMS AND
POWER OUTLETS AS PER
CODE
PROVIDE ALL NEW FIXTURES
FOR SAME
NEW ELECTRICAL PANEL
W/SALVAGED WOOD COVER
10
CONCRETE SLAB
V.I.F.
11' - 11 3/4"12' - 6"V.I.F.
11' - 11 1/4"13' - 4"13' - 6"37' - 3"13' - 4 3/4"NEW LOCKABLE BARN DOORS TO MATCH
ORIGINAL BARN DOORS ON SOUTH SIDE
Scale
Project number
Date
Drawn by
Checked by
1/4" = 1'-0"
A-2
1ST & 2ND FLOOR FL
PLANS
NORTHAMPTON
HISTORIC
1-13-22
Author
1/4" = 1'-0"2 T. O. BEAM
1/4" = 1'-0"1 LEVEL 1