Loading...
1-22_WORKING DRAWINGS - Sheet - A-2 - 1ST & 2ND FLOOR FL PLANSGFI GFI GFI GFI EXISTING STRUCTURE TO REMAIN AND BE REPAIRED WHERE REQUIRED FOR STABILITY SECOND FLOOR STRUCTURE TO REMAIN W/FLOOR BOARDS REMOVED IN SHADED AREA A-43 3 A-5 7 A-6 5 A-6 2 A-5 1 A-5 1 A-6 A-3 A-3 2 3 EXISTING BARN - TO BECOME A MULTI-PURPOSE & EXHIBIT SPACE 2 A-2.6 PORTION OF ORIGINAL STALL TO BE MOVED AGAINST THIS WALL FOR DISPLAY PREP AREA GENDER NEUTRAL WC wh3' - 6"GENDER NEUTRAL WC EXISTING STRUCTURE TO REMAIN - TYP, - FOLLOW STRUCTURAL DRAWINGS FOR ALL STRUCTURAL REPAIRS DASHED LINE INDICATES BALCONY STRUCTURE ABOVE EXISTING BARN DOORS TO BE RE-BUILT TO MATCH ORIGINAL LEFT DOOR MUST HAVE A 180 DEGREE SWING - BOTH DOORS MUST BE ABLE TO FIX IN THE OPEN POSITION FOR EVENTS GREEN ROOM A-2.6 1 A-2.5 1 A-2.5 2 5 A-2.59 6 73 A-2.6 8 9 7 A-2.6 - 4 A-2.6 5 STORAGE ROOM 4 8 3 6 - EXISTING DOOR TO BE RE-BUILT TO MATCH ORIGINAL - DOOR MUST BE ABLE TO FIX IN THE OPEN POSITION FOR EVENTS GALVANIZED DOWNSPOUT TO HOOK INTO NEW DRAINAGE SYSTEM GALVANIZED DOWNSPOUT TO HOOK INTO NEW DRAINAGE SYSTEM EXISTING DOOR TO BE REPAIRED AS REQUIRED - DOOR MUST BE ABLE TO FIX IN THE OPEN POSITION FOR EVENTS 2 1/2" - 3" BLUSTONE PAD SET ON6-8" CONPACTED CRUSHED STONE 4' - 0"V.I.V.4' - 4"NEW LOCKABLE POCKET DOOR W/ADA COMPATIBLE HARDWARE NEW STONE PATIO "BIG ASS" FAN WHERE INDICATED - SEE SECTION FOR HEIGHT NEW 6" X 1 3/8" THICK HEMLOCK FLOORING SET ON 2 X 4 COMPOSITE SLEEPERS SPACED 2'- 2'-6" OC SET ON 6-8" COMPACTED STONE SET ON A 10 MIL VAPOR BARRIER TREAT ALL WOOD SURFACES PRIOR TO INSTALLATION W/BORIC ACID & OIL SEALANT BARN AND "L" BUILDING LENGTH RUNS E/W DASHED LINE REPRESENTS TIMBER- FRAME STRUCTURE W/EXTERIOR SHEATHING AND RE-PURPOSED HORIZONTAL WOOD SIDING - VARIOUS WIDTHS TO MATCH THE BARN ATTACH BLACK-OUT FRIT ON WINDOW EXISTING BARN DOOR TO BE RE-BUILT TO MATCH ORIGINAL POCKET BETWEEN BARN AND NEW ADDITION TO HOUSE DOOR WHEN OPEN NEW "ELL" BUILDING BUILT IN SAME LOCATION AS EXISTING TO BE DEMOLISHED FIN. FL. ELEV. 0'-8" (95.75) NEW ADDITION SEE 1/A2.6 FOR ADDITIONAL "ELL" BUILDING NOTES 6' - 3 3/8"SEE 1/A2.5 FOR ADDITIONAL BARN ADDITION NOTES PROVIDE ELECTRICAL UPGRADE FOR GENERAL LIGHTING, THEATER LIGHTING, EXHIBIT LIGHTING, FANS, EMERGENCY SYSTEMS AND POWER OUTLETS AS PER CODE PROVIDE ALL NEW FIXTURES FOR SAME NEW ELECTRICAL PANEL W/SALVAGED WOOD COVER 10 CONCRETE SLAB V.I.F. 11' - 11 3/4"12' - 6"V.I.F. 11' - 11 1/4"13' - 4"13' - 6"37' - 3"13' - 4 3/4"NEW LOCKABLE BARN DOORS TO MATCH ORIGINAL BARN DOORS ON SOUTH SIDE Scale Project number Date Drawn by Checked by 1/4" = 1'-0" A-2 1ST & 2ND FLOOR FL PLANS NORTHAMPTON HISTORIC 1-13-22 Author 1/4" = 1'-0"2 T. O. BEAM 1/4" = 1'-0"1 LEVEL 1