21024 5 franklin st Ind Housing Inc permit 10 mar 2022Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
COVER SHEET
000
Proposed Renovations for
INDEPENDENT HOUSING SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts
LOCUS PLAN
DRAWING LIST
000 COVER SHEET
D-100 BASEMENT DEMOLITION PLAN
D-101 FIRST FLOOR DEMOLITION PLAN
D-102 SECOND FLOOR DEMOLITION PLAN
A-100 PROPOSED BASEMENT PLAN
A-101 PROPOSED FIRST FLOOR PLAN
A-102 PROPOSED SECOND FLOOR PLAN
A-110 PROPOSED BASEMENT REFLECTED CEILING PLAN
A-111 PROPOSED FIRST REFLECTED CEILING PLAN
A-112 PROPOSED SECOND REFLECTED CEILING PLAN
BUILDING CODE:
IBC 2015 BUILDING CODE, IEBC 2015 EXISTING BUILDING CODE, MASSACHUSETTS STATE BUILDING CODE, 780 CMR 9TH EDITION
BUILDING USE GROUP, EXISTING:B, BUSINESS (OFFICES)
BUILDING USE GROUP, PROPOSED:R-3, BOARDING HOUSE (NON-TRANSIENT, 16 OR FEWER OCCUPANTS)
BUILDING CONSTRUCTION TYPE:IIB -- NON-COMBUSTIBLE, UNPROTECTED (MASONRY WALLS, STEEL FLOOR FRAMING, CONCRETE FLOOR SLAB)
BUILDING AREA:2,347 SF BASEMENT
2,390 SF 1ST FLOOR
2,310 SF 2ND FLOOR
ELEVATOR:THERE IS AN EXISTING ELEVATOR SERVING THE BASEMENT, 1ST & 2ND FLOORS WHICH WILL REMAIN. THE BUILDING IS ACCESSIBLE AT GRADE VIA ELEVATOR LOBBY.
SPRINKLERS: THE BUILDING IS NOT PRESENTLY SPRINKLERED, BUT HAS AN EXISTING, DECOMMISIONED SPRINKLER CONNECTION. A NEW SPRINKLER SYSTEM WILL BE INSTALLED AND RE-CONNECTED TO THE EXISITNG
SYSTEM. SPRINKLER SYSTEM TO BE DESIGNED BY SPRINKLER INSTALLER AND THEIR ENGINEER(S).
LIFE SAFETY: THE BUILDING HAS AN EXISTING, RECENTLY INSTALLED AND UPGRADED LIFE SAFETY AND ALARM SYSTEM. THE SYSTEM SHALL BE MODIFIED AND / OR UPGRADED AS REQUIRED BY THE OWNER'S ALARM
COMPANY FOR THE NEW USE GROUP. DESIGN AND LAYOUT BY ALARM COMPANY.
APARTMENT UNITS (SINGLE RESIDENT OCCUPANCY, SRO): 16 S.R.O. APARTMENTS WILL BE BUILT AS PART OF THIS PROJECT, EIGHT (8) UNITS PER FLOOR. ALL UNITS WILL BE ADA ACCESSIBLE. ONE (1) UNIT PER FLOOR WILL
HAVE A TOILET AND SINK INSTALLED AS PART OF THEIR DESIGN FOR FUTURE TENANTS WITH NEED FOR PRIVATE REST ROOM AREA.
RESTROOMS: THERE ARE TWO EXISTING, ACCESSIBLE RESTROOMS ON THE 1ST AND 2ND FLOORS. ONE (1) RESTROOM EACH FLOOR WILL REMAIN "AS IS" AND ONE (1) RESTROOM WILL HAVE AN ADJUSTIBLE, ADA COMPLIANT
SHOWER HEAD INSTALLED FOR THE USE OF THE RESIDENTS. A NEW FLOOR DRAIN WILL BE INSTALLED IN THE SHOWER ROOMS. EXISTING TOILET AND SINK WILL REMAIN IN THE SHOWER ROOMS. THERE WILL BE ONE (1)
NON-ADA POWDER ROOM INSTALLED ON THE 1ST AND 2ND FLOORS. ONE (1) ROOM ON THE 1ST AND 2ND FLOORS WILL HAVE A PRIVATE TOILET AND SINK PROVIDED FOR POTENTIAL TENANTS IN NEED OF PRIVATE BATH. AN
EXISTING SHOWER ROOM AT THE BASEMENT LEVEL WILL BE OUTFITTED WITH A NEW, ROLL-IN TUB FOR ASSISTED BATHING OF TENANTS BY THE NURSE OR DOCTOR ON CALL AT THE RESIENCE.
AN EXISTING KITCHENETTE WILL BE AVAILABLE FOR THE USE OF TENANTS AT THE BASEMENT LEVEL.
COMMUNITY SPACE WILL BE PROVIDED FOR THE TENANTS AT THE BASEMENT LEVEL.
OFFICES FOR VISITING NURSE AND DOCTOR WILL BE PROVIDED AT THE BASEMENT LEVEL.
LAUNDRY SPACE FOR TENANTS WILL BE PROVIDED AT THE BASEMENT LEVEL.
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
UP
UP
elevator
MODELNUMBERTRADENAMEPRODUCTMATERIAL
UP
UP
DW
HVAC
WD
HWH
BASEMENT DEMOLITION PLAN
Scale: 1/4" = 1'-0"1
DEMO EXISTING PARTITION
WALL AND ALL ASSOCIATED
MATERIALS.
DEMO EXISTING CARPET
TILE FLOORING. PREP
SUB-FLOOR AS REQ'D FOR
NEW VCT FLOORING.
DEMO EXISTING CARPET
TILE FLOORING. PREP
SUB-FLOOR AS REQ'D FOR
NEW VCT FLOORING.
DEMO DOOR &
FRAME. INFILL
OPENING.
REMOVE WASHER &
DRYER. MODIFY
PLUMBING AS
REQUIRED FOR NEW
MOP SINK.
DEMO EXISTING
SHOWER. MODIFY
PLUMBING AS
REQUIRED FOR NEW
ADA WALK-IN TUB.
DEMO EXISTING HOT WATER
HEATER. INSTALL NEW WATER
HEATER. DESIGN & LAYOUT BY
PLUMBING.
NOTE: NCREASE
DOMESTIC WATER
SUPPLY TO BUILDING.
DESIGN & LAYOUT BY
PLUMBING.
BASEMENT
DEMOLITION PLAN
D-100
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
elevator
DN UP
DN
DN
UP
UP
DN
HVAC
1ST FLOOR DEMOLITION PLAN
Scale: 1/4" = 1'-0"1
DEMO EXISTING WINDOW.
EXPAND OPENING AS
REQUIRED FOR NEW
CASEMENT EGRESS WINDOW.
SEE FLOOR PLANS.
DEMO EXISTING WINDOW.
EXPAND OPENING AS
REQUIRED FOR NEW
CASEMENT EGRESS WINDOW.
SEE FLOOR PLANS.
DEMO WALL AND
ASSOCIATED
MATERIALS
DEMO WALL AND
ASSOCIATED
MATERIALS
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO WALL AND
ASSOCIATED
MATERIALS, TYPICAL
DEMO WALL AND
ASSOCIATED
MATERIALS
DEMO DOOR &
FRAME. INFILL
OPENING.
DEMO DOOR,
FRAME, WALL AND
ASSOCIATED
MATERIALS
DEMO WALL AND
ASSOCIATED
MATERIALS
CORE DRILL
FLOOR FOR
FLOOR DRAIN.
CORE DRILL
FLOOR FOR
FLOOR DRAIN.
CORE DRILL
FLOOR FOR
FLOOR DRAIN.EXISTING WALL TO
REMAIN. EXTEND TOP OF
WALL TO UNDERSIDE OF
THE FLOOR DECK ABOVE.
DEMO SHEET ROCK ON
ONE SIDE OF WALL.
INSTALL MINERAL WOOL
INSULATION IN STUD
POCKETS (3" THICK).
INSTALL NEW 5/8" GWB
AND PAINT.
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
FIRST FLOOR
DEMOLITION PLAN
D-101
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
elevator
DN UP
DN
DN
HVAC
2ND FLOOR DEMOLITION PLAN
Scale: 1/4" = 1'-0"1
DEMO EXISTING WINDOW.
EXPAND OPENING AS
REQUIRED FOR NEW
CASEMENT EGRESS WINDOW.
SEE FLOOR PLANS.
DEMO EXISTING WINDOW.
EXPAND OPENING AS
REQUIRED FOR NEW
CASEMENT EGRESS WINDOW.
SEE FLOOR PLANS.
DEMO WALL AND
ASSOCIATED
MATERIALS,
TYPICAL
DEMO WALL AND
ASSOCIATED
MATERIALS
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO CARPET TILES.
PREP FLOOR FOR NEW
LVT FLOORING.
DEMO WALL AND
ASSOCIATED
MATERIALS, TYPICAL
DEMO WALL AND
ASSOCIATED
MATERIALS
DEMO DOOR &
FRAME. INFILL
OPENING.
DEMO WALL AND
ASSOCIATED
MATERIALS
CORE DRILL
FLOOR FOR
FLOOR DRAIN.
CORE DRILL
FLOOR FOR
FLOOR DRAIN.
CORE DRILL
FLOOR FOR
FLOOR DRAIN.EXISTING WALL TO
REMAIN. EXTEND TOP OF
WALL TO UNDERSIDE OF
THE FLOOR DECK ABOVE.
DEMO SHEET ROCK ON
ONE SIDE OF WALL.
INSTALL MINERAL WOOL
INSULATION IN STUD
POCKETS (3" THICK).
INSTALL NEW 5/8" GWB
AND PAINT.
DEMO WALL AND
ASSOCIATED
MATERIALS
RE-OPEN EXISTING
FRAMED OPENING.DEMO CARPET TILES. PREP FLOOR FOR
NEW LVT FLOORING.
SECOND FLOOR
DEMOLITION PLAN
D-102
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
UP
UP
existing elevator
MODELNUMBERTRADENAMEPRODUCTMATERIAL
UP
UP
DW
TVHVACWDWDD-1
computercomputer mop sink
unexcavated unexcavated HWH
WALL KEY:
EXISTING WALL TO REMAIN
NEW WALL - UL419
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF STRUCTURE ABOVE
25 GA. FURRING CHANNELS INSTALLED HORIZONTALLY, 24" OC., ONE SIDE
5/8" GWB EACH SIDE, PRIME & PAINT
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 54
1-HR. RATED
EXISTING WALL - ADD SOUND PROOFING
EXTEND EXISTING 3-5/8" METAL STUDS TO UNDERSIDE OF STRUCTURE ABOVE
EXISTING 5/8" GWB AT EXTERIOR TO REMAIN.
ADD 5/8" GWB TO INTERIOR OF WALL.
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 45
NEW WALL -
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF CEILING ABOVE.
5/8" GWB EACH SIDE, PRIME & PAINT
ELEVATOR
MACHINE
ROOM
STORAGE
TV ROOM
DINING
AREA
KITCHEN
BATH
NEW WALK-IN TUB
JANITOR'S
CLOSET
STAIR-2
STAIR-1
STORAGEMECHANICALCLOSETMECHANICAL
CLOSETSTORAGE
PHYSICIAN'S
OFFICE
NURSE'S
STATION
LAUNDRY
ROOM
CURTAIN & RODINFILL EXISTING DOOR
OPENING
NEW MOP SINK
NEW VCT FLOORING
NEW VCT
FLOORING
NEW VCT FLOORING
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
VCT FLOORING VCT FLOORING EXIST FLOORINGEXIST FLOORING
EXIST
FLOORING
EXIST
FLOORING5'-7"6"±9'-11"14'-2 1/2"3 5/8"±13'-2"
±8'-10"
NEW COUNTER &
OVERHEAD
CABINETS
INSTALL NEW HOT
WATER HEATER.
DESIGN & SPEC BY
PLUMBING.EX. DOOREX. DOOREX. DOOREX. DOOR
EX. DOOREX. DOOREX. DOOREX. DOOREX. DOOR EX. DOOREX. DOOREX. DOOREX. DOOR
EX. DOOR
EX. DOOREX. DOORPROPOSED BASEMENT PLAN
Scale: 1/4" = 1'-0"1
PROPOSED BASEMENT
PLAN
A-100
Door Schedule
Nominal Size Door Style
Mark WidthHeightThicknessConfiguration
Side LightsL Sidelt WidR Sidelt WidComments
D-1 Physician's Office 3'0"7'0"1 3/4"Pocket Simple N/A N/A
D-2 ADA #7 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-3 ADA #8 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-4 ADA #5 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-5 ADA #4 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-6 ADA #3 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-7 ADA #2 3'6"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-8 ADA #1 3'6"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-9 Restroom, 1st Floor 2'8"7'0"1 1/2"Pocket Simple N/A N/A
D-10 ADA #16 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-11 ADA #15 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-12 ADA #14 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-13 ADA #13 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-14 ADA #12 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-15 ADA #11 3'0"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-16 ADA #10 3'6"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-17 ADA #9 3'6"7'0"1 3/4"Swing Simple N/A N/A Provide ADA rated privacy lock set with lever handle, ADA compliant door closer
D-18 Restroom, 2nd Floor 2'8"7'0"1 1/2"Pocket Simple N/A N/A
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
exisitng elevator
DN UP
DN
UP
UP
DN
HVAC
D-4
D-5D-6
D-9
floor
drainnew hosebibbMODELNUMBERTRADENAMEPRODUCTMATERIAL
new hose
bibb
D-7D-8
D-2 D-3
floor
drain
DN
floor
drain
new adj.showerhead &controlsWALL KEY:
EXISTING WALL TO REMAIN
NEW WALL - UL419
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF STRUCTURE ABOVE
25 GA. FURRING CHANNELS INSTALLED HORIZONTALLY, 24" OC., ONE SIDE
5/8" GWB EACH SIDE, PRIME & PAINT
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 54
1-HR. RATED
EXISTING WALL - ADD SOUND PROOFING
EXTEND EXISTING 3-5/8" METAL STUDS TO UNDERSIDE OF STRUCTURE ABOVE
EXISTING 5/8" GWB AT EXTERIOR TO REMAIN.
ADD 5/8" GWB TO INTERIOR OF WALL.
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 45
STAIR-2
STAIR-1
ADA
SHOWER
ROOM
ADA
RESTROOM
RESTROOM
TRASH
ADA #1
ADA #2
ADA #3 ADA #4
ADA #5
ADA #6
ADA #7
ADA #8
clothes rod @ 48"shelf @ 54" CURTAIN &
ROD
NEW WALL -
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF CEILING ABOVE.
5/8" GWB EACH SIDE, PRIME & PAINT
clothes rod @ 48"
shelf @ 54"
clothes rod @ 48"
shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"
shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"shelf @ 54" ENTRY
LOBBY
6" WALL AT POCKET
DOOR W/ ADA
THRESHOLD
±16'-4 1/4"3 5/8"10'-11 1/2"9'-0"3 5/8"9'-0"3 5/8"±9'-0"
ALIGN3'-6"7'-5 1/4"3 5/8"5'-1 1/4"3 5/8"±6'-5 1/2"10'-7"5'-5"2'-0"2'-0"ALIGNALIGNALIGN
2'-3"2'-3"±5'-6 1/2"3 5/8"5'-1 1/4"3 5/8"5'-2 3/4"
3'-6"2'-0"INFILL DOOR
OPENING
1'-11"1'-11"4'-9"11'-3"4'-9"3'-6"2'-0"2'-0"
INFILL EXISTING
CASED OPENING.
INSTALL NEW DOOR
& FRAME.5'-6"EXTEND &
SOUNDPROOF
EXISTING
PARTITION WALL
NEW EGRESS SIZE
CASEMENT WINDOW IN
EXISTING, ENLARGED
OPENING. MARVIN ELEVATE
ELCA3347E OR APPROVED
EQUAL.
NEW EGRESS SIZE
CASEMENT WINDOW IN
EXISTING, ENLARGED
OPENING. MARVIN ELEVATE
ELCA3347E OR APPROVED
EQUAL.
LVT FLOORING
LVT FLOORING
LVT FLOORING LVT FLOORING
LVT FLOORING
LVT FLOORING
LVT FLOORINGLVT FLOORING
EXISITNG
EPOXY
EPOXY
LVT FLOORING LVT FLOORING
LVT FLOORING
EXIST FLOORING
EXIST FLOORING
3'-6"2'-0"5'-4"10'-8"9'-0 1/4"3 5/8"9'-0 1/4"3 5/8"±9'-0 1/2"
6'-4 3/4"3 5/8"5'-1 1/4"3 5/8"5'-3 1/4"3 5/8"±10'-0"3'-6"2'-0"2'-0"
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
TILE
ADD NEW ADA
COMPLIANT SHOWER
HEAD, GRAB BAR &
CONTROLS. INSTALL NEW
FLOOR DRAIN & HOSE
BIBB CONNECTION TO
EXISTING BATHROOM.
NEW EPOXY PAINT
FLOORING. FRP OR
EPOXY PAINT AT WALLS.
NEW ADA COMPLIANT
THRESHOLD AT DOOR.
INSTALL A WALL
MOUNTED, FOLDING
SEAT OPPOSITE THE
ENTRY DOOR, 17" ABOVE
FLOOR.
EXISTING ADA
COMPLIANT RESTROOM
TO REMAIN "AS IS"
ADD NEW FLOOR DRAIN,
& HOSE BIBB
CONNECTION AT NEW
PRIVATE BATHROOM.
NEW TILE FLOORING AT
BATH AREA WITH ADA
COMPLIANT TRANSITION
AT LVT FLOORING.2'-0"2'-0"ALIGNNEW ADA COMPLIANT
WATER FOUNTAIN W/
BOTTLE FILLER.10'-8"5'-4"±10'-10"EX. DOOREX. DOOREX. DOOREX. DOOREX. DOOREX. DOOREX. DOOR
PROPOSED 1ST FLOOR PLAN
Scale: 1/4" = 1'-0"1
PROPOSED FIRST
FLOOR PLAN
A-101
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
D-12
exisitng elevator
UP
DN
DN
HVAC
D-14D-15
D-18
floor
drainnew hosebibbMODELNUMBERTRADENAMEPRODUCTMATERIAL
new hose
bibb
D-16D-17
D-10 D-11
floor
drain
floor
drain
D-13
new adj.showerhead &controlsEX. DOORWALL KEY:
EXISTING WALL TO REMAIN
NEW WALL - UL419
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF STRUCTURE ABOVE
25 GA. FURRING CHANNELS INSTALLED HORIZONTALLY, 24" OC., ONE SIDE
5/8" GWB EACH SIDE, PRIME & PAINT
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 54
1-HR. RATED
EXISTING WALL - ADD SOUND PROOFING
EXTEND EXISTING 3-5/8" METAL STUDS TO UNDERSIDE OF STRUCTURE ABOVE
EXISTING 5/8" GWB AT EXTERIOR TO REMAIN.
ADD 5/8" GWB TO INTERIOR OF WALL.
MIN. 3" MINERAL WOOL BATT INSULATION.
STC 45
NEW WALL -
3-5/8" METAL STUDS, 25 GA. @ 16" OC. TO UNDERSIDE OF CEILING ABOVE.
5/8" GWB EACH SIDE, PRIME & PAINT
STAIR-2
STAIR-1
ADA
SHOWER
ROOM
ADA
RESTROOM
RESTROOM
TRASH
ADA #9
ADA #10
ADA #11 ADA #12
ADA #13
ADA #14
ADA #15
ADA #16
clothes rod @ 48"shelf @ 54" CURTAIN &
ROD
clothes rod @ 48"
shelf @ 54"
clothes rod @ 48"
shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"
shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"shelf @ 54" clothes rod @ 48"shelf @ 54" 6" WALL AT POCKET
DOOR W/ ADA
THRESHOLD.
±16'-4 1/4"3 5/8"10'-11 1/2"9'-0"3 5/8"9'-0"3 5/8"±9'-0"
ALIGN3'-6"7'-5 1/4"3 5/8"5'-1 1/4"3 5/8"±6'-5 1/2"10'-7"5'-5"2'-0"2'-0"ALIGNALIGNALIGN
2'-3"2'-3"±5'-6 1/2"3 5/8"5'-1 1/4"3 5/8"5'-2 3/4"
3'-6"2'-0"INFILL DOOR
OPENING
1'-11"1'-11"4'-9"11'-3"4'-9"3'-6"2'-0"2'-0"
INFILL EXISTING
CASED OPENING.
INSTALL NEW DOOR
& FRAME.5'-6"EXTEND &
SOUNDPROOF
EXISTING
PARTITION WALL
NEW EGRESS SIZE
CASEMENT WINDOW IN
EXISTING, ENLARGED
OPENING. MARVIN ELEVATE
ELCA3347E OR APPROVED
EQUAL.
NEW EGRESS SIZE
CASEMENT WINDOW IN
EXISTING, ENLARGED
OPENING. MARVIN ELEVATE
ELCA3347E OR APPROVED
EQUAL.
LVT FLOORING
LVT FLOORING
LVT FLOORING LVT FLOORING
LVT FLOORING
LVT FLOORING
LVT FLOORINGLVT FLOORING
EXIST
EPOXY
LVT FLOORING LVT FLOORING
LVT FLOORING
EXIST FLOORING
3'-6"2'-0"5'-4"10'-8"9'-0 1/4"3 5/8"9'-0 1/4"3 5/8"±9'-0 1/2"
6'-4 3/4"3 5/8"5'-1 1/4"3 5/8"5'-3 1/4"3 5/8"±10'-0"3'-6"2'-0"2'-0"
EXIST FLOORING
EXIST FLOORING
EXIST FLOORING
TILE
ADD NEW FLOOR DRAIN,
& HOSE BIBB
CONNECTION AT NEW
PRIVATE BATHROOM.
NEW TILE FLOORING AT
BATH AREA WITH ADA
COMPLIANT TRANSITION
AT LVT FLOORING.2'-0"2'-0"ALIGNNEW ADA COMPLIANT
WATER FOUNTAIN W/
BOTTLE FILLER.10'-8"5'-4"ROOF BELOW
ROOF BELOW
EPOXY
ADD NEW ADA
COMPLIANT SHOWER
HEAD, GRAB BAR &
CONTROLS. INSTALL NEW
FLOOR DRAIN & HOSE
BIBB CONNECTION TO
EXISTING BATHROOM.
NEW EPOXY PAINT
FLOORING. FRP OR
EPOXY PAINT AT WALLS.
NEW ADA COMPLIANT
THRESHOLD AT DOOR.
INSTALL A WALL
MOUNTED, FOLDING
SEAT OPPOSITE THE
ENTRY DOOR, 17" ABOVE
FLOOR.
EXISTING ADA
RESTROOM TO REMAIN
"AS IS"EX. DOOREX. DOOREX. DOOREX. DOORPROPOSED 2ND FLOOR PLAN
Scale: 1/4" = 1'-0"1
PROPOSED SECOND
FLOOR PLAN
A-102
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
UP
UP
existing elevator
MODELNUMBERTRADENAMEPRODUCTMATERIAL
UP
UP
DW
TVHVACWDWD
mop sink
unexcavated unexcavated HWH
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
HS
HSHSFP
HSHSHSFE
FP
supply
EXITsupply
supply
EXITsupply supply supplySPEAKER
EX.EX.
EX.
EX.
EX.
EX.
EX.EX.EX.
EX.
EX.
supply
EX.EX.
SLOPED CEILING TILES AT
BASEMENT WINDOWS,
TYPICAL
FE
HS
HSPROVIDE WALL MOUNT,
POWER & DATA/CABLE
CONNECTION AT NEW
WALL MOUNTED TV
LOCATION.
supply
NEW
HS
GENERAL NOTES:
FINAL HVAC LAYOUT & BALANCING TO BE PROVIDED BY HVAC CONTRACTOR.
FINAL ELECTRICAL LAYOUT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
FINAL LIFE SAFETY & ALARM DESIGN TO BE PROVIDED BY ALARM CONTRACTOR.
FINAL SPRINKLER LAYOUT & DESIGN TO BE PROVIDED BY SPRINKLER CONTRACTOR.
ELECTRICAL OUTETS AND CONTROLS TO REMAIN WHERE UNEFFECTED BY RENOVATION.
PROVIDE ADDITIONAL OUTLET(S‚ AND CONTROL(S) AS REQUIRED BY CODE.
ELECTRICAL TO COORDINATE NEW OUTLET AND CONTROL LOCATIONS WITH OWNER IN
FIELD PRIOR TO INSTALLATION.
PROVIDE NEW ELECTRICAL OUTLETS IN DWELLING UNITS AS REQUIRED BY THE
ELECTRICAL CODE.
GC TO COORDINATE WORK BETWEEN ALL TRADES.
KEY:
EXIT
FACP
STROBE
FE
HS
S
SMOKE
CO
FP
KNOX
EXIT SIGN
EMERGENCY LIGHT, EXIST
EXTERIOR STROBE LIGHT
FIRE EXTINGUISHER
HORN STROBE
STROBE LIGHT
FIRE ALARM PULL STATION
COMBINATION SMOKE & CARBOM MONOXIDE DETECTOR
FIRE ALARM CONTOL PANEL.
KNOX BOX
EXH
FAN BATHROOM EXHAUST FAN & LIGHT
2X4 LED -- reuse existing fixtures in new locations
EX.EXISTING SCONCE
EX.EXISTING SURFACE MOUNTED FIXTURE
supply
HVAC SUPPLY
RETURN HVAC RETURN
EXISTING KEYLESS FIXTURE
EMERGENCY LIGHT, NEW
LIGHT SWITCH
OUTLET
OUTLET, GFI
gfi
OUTLET, MOUNTING HEIGHT ABOVE FINISH FLOOR
48"
OUTLET, 208v
S
cabledatadatadata gfi48"gfi48"48"PROPOSED BASEMENT REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"1
PROPOSED BASEMENT
REFLECTED CEILING
PLAN
A-110
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
exisitng elevator
DN UP
DN
UP
UP
DN
HVAC
floor
drainnew hosebibbMODELNUMBERTRADENAMEPRODUCTMATERIAL
new hose
bibb
floor
drain
DN
floor
drain
new adj.showerhead &controlsFACPHSFP
KNOX
STROBE
SMOKE
CO
HS HS SMOKE
CO
SMOKE
CO SMOKE
CO
FP
EXH
FAN
S
S
SMOKE
CO
HSHSHSEXIT
EXIT
EXIT
EXITEXIT
EXH
FAN
EX.
FP
SMOKE
CO
SMOKE
CO
FE
FE
EX.
supply
EX.
EX.
EX.
EX.
supply
EX.EX.
supply
EX.
supply
RETURN
supply
supply
EX.
supplysupplysupply
RETURN
EX.
EX.
supply
supply supply
EX.EX.EX.
EXIST.
RETURN
GENERAL NOTES:
FINAL HVAC LAYOUT & BALANCING TO BE PROVIDED BY HVAC CONTRACTOR.
FINAL ELECTRICAL LAYOUT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
FINAL LIFE SAFETY & ALARM DESIGN TO BE PROVIDED BY ALARM CONTRACTOR.
FINAL SPRINKLER LAYOUT & DESIGN TO BE PROVIDED BY SPRINKLER CONTRACTOR.
ELECTRICAL OUTETS AND CONTROLS TO REMAIN WHERE UNEFFECTED BY RENOVATION.
PROVIDE ADDITIONAL OUTLET(S‚ AND CONTROL(S) AS REQUIRED BY CODE.
ELECTRICAL TO COORDINATE NEW OUTLET AND CONTROL LOCATIONS WITH OWNER IN
FIELD PRIOR TO INSTALLATION.
PROVIDE NEW ELECTRICAL OUTLETS IN DWELLING UNITS AS REQUIRED BY THE
ELECTRICAL CODE.
GC TO COORDINATE WORK BETWEEN ALL TRADES.
RETURN
HSHS
HS
HSS
KEY:
EXIT
FACP
STROBE
FE
HS
S
SMOKE
CO
FP
KNOX
EXIT SIGN
EMERGENCY LIGHT, EXIST
EXTERIOR STROBE LIGHT
FIRE EXTINGUISHER
HORN STROBE
STROBE LIGHT
FIRE ALARM PULL STATION
COMBINATION SMOKE & CARBOM MONOXIDE DETECTOR
FIRE ALARM CONTOL PANEL.
KNOX BOX
EXH
FAN BATHROOM EXHAUST FAN & LIGHT
2X4 LED -- reuse existing fixtures in new locations
EX.EXISTING SCONCE
EX.EXISTING SURFACE MOUNTED FIXTURE
supply
HVAC SUPPLY
RETURN HVAC RETURN
EXISTING KEYLESS FIXTURE
EMERGENCY LIGHT, NEW
LIGHT SWITCH
OUTLET
OUTLET, GFI
gfi
OUTLET, MOUNTING HEIGHT ABOVE FINISH FLOOR
48"
OUTLET, 208v SS
SSSSSSHSEXH
FAN
gfigfi
S
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
PROPOSED 1ST FLOOR REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"1
PROPOSED FIRST
FLOOR REFELECTED
CEILING PLAN
A-111
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 11/30/2021 Pricing set
Sheet Title
Scale:
3/10/2022
JPB
JPB
21-024
AS NOTED
PERMIT - 3/10/2022
Proposed Renovations for
INDEPENDENT
HOUSING
SOLUTIONS, INC.
5 Franklin Street
Northampton, Massachusetts This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.com2 3/10/2022 PERMIT
exisitng elevator
UP
DN
DN
HVAC
floor
drainnew hosebibbMODELNUMBERTRADENAMEPRODUCTMATERIAL
new hose
bibb
floor
drain
floor
drain
new adj.showerhead &controlsFP
SMOKE
CO
SMOKE
CO
SMOKE
CO
FP
HS
S
SMOKE
CO
HS
HSHSEXITEXITEXH
FAN
EXH
FAN
FEEX.
EX.
EX.
supply
supply
ACCESS
PANEL
EX.EX.EX.EX.
supply
EX.
EX.EX.
EX.
EX.
supply
SMOKE
CO
HSSMOKE
CO
supply
RETURN
supply
supply supply
supply
supply
RETURN
supply
supply supply
SPEAKER
RETURN
RETURN
KEY:
EXIT
FACP
STROBE
FE
HS
S
SMOKE
CO
FP
KNOX
EXIT SIGN
EMERGENCY LIGHT, EXIST
EXTERIOR STROBE LIGHT
FIRE EXTINGUISHER
HORN STROBE
STROBE LIGHT
FIRE ALARM PULL STATION
COMBINATION SMOKE & CARBOM MONOXIDE DETECTOR
FIRE ALARM CONTOL PANEL.
KNOX BOX
EXH
FAN BATHROOM EXHAUST FAN & LIGHT
2X4 LED -- reuse existing fixtures in new locations
EX.EXISTING SCONCE
EX.EXISTING SURFACE MOUNTED FIXTURE
supply
HVAC SUPPLY
RETURN HVAC RETURN
EXISTING KEYLESS FIXTURE
EMERGENCY LIGHT, NEW
GENERAL NOTES:
FINAL HVAC LAYOUT & BALANCING TO BE PROVIDED BY HVAC CONTRACTOR.
FINAL ELECTRICAL LAYOUT TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
FINAL LIFE SAFETY & ALARM DESIGN TO BE PROVIDED BY ALARM CONTRACTOR.
FINAL SPRINKLER LAYOUT & DESIGN TO BE PROVIDED BY SPRINKLER CONTRACTOR.
ELECTRICAL OUTETS AND CONTROLS TO REMAIN WHERE UNEFFECTED BY RENOVATION.
PROVIDE ADDITIONAL OUTLET(S‚ AND CONTROL(S) AS REQUIRED BY CODE.
ELECTRICAL TO COORDINATE NEW OUTLET AND CONTROL LOCATIONS WITH OWNER IN
FIELD PRIOR TO INSTALLATION.
PROVIDE NEW ELECTRICAL OUTLETS IN DWELLING UNITS AS REQUIRED BY THE
ELECTRICAL CODE.
GC TO COORDINATE WORK BETWEEN ALL TRADES.
S
EXH
FAN HSHSHSS
SMOKE
CO
S LIGHT SWITCH
OUTLET
OUTLET, GFI
gfi
OUTLET, MOUNTING HEIGHT ABOVE FINISH FLOOR
48"
OUTLET, 208v SHSS
Sgfi
SHSSHSSHSS
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
SMOKE
CO
PROPOSED 2ND FLOOR REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"1
PROPOSED SECOND
FLOOR REFLECTED
CEILING PLAN
A-112