Loading...
EZ CONSTRUCTION-Floor- Flush Beam (1)Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2272 @ 2"3347 (2.25")Passed (68%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1939 @ 1' 1"6318 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)7455 @ 6' 9 1/2"11775 Passed (63%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.322 @ 6' 9 1/2"0.331 Passed (L/494)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.497 @ 6' 9 1/2"0.663 Passed (L/320)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 3.50"2.25"1.53"812 1494 2306 1 1/4" Rim Board 2 - Stud wall - SPF 3.50"2.25"1.53"812 1494 2306 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)13' 5" o/c Bottom Edge (Lu)13' 5" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 13' 5 3/4"N/A 9.7 -- 1 - Uniform (PSF)0 to 13' 7" (Front)11'10.0 20.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED Level, Floor: Flush Beam 2 piece(s) 1 3/4" x 9 1/2" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 11/5/2021 5:42:54 PM UTC Kyle Lewis BOILARD LUMBER (413) 505-5324 klewis@boilards.com ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 File Name: EZ CONSTRUCTION Page 1 / 1