Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Lee John - old
PAGE NAME: PV4 STANDOFF SCALE NTSS3 SOLAR MODULE RAIL L-FOOT QMSE-LAG SHINGLE COMPOSITE SHINGLE 5"X 5 16" - LAG 2.5" MIN. EMBEDMENT PER SCREW 2X8 NOMINAL LEE, JOHN LEE RESIDENCE 212 SOUTH ST NORTHAMPTON, MA,1060 +1-413-426-1304 RACKING: IRONRIDGE XR-100 JOB NUMBER: 1135 UTILITY: NG OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 1/2/2022 PAGE: HA 10.00 kW AC STRUCTURAL VIEWS REVIEW BY: MS12.00 kW DC ROOF SOLAR SYSTEM MODULES: (30) HANWHA Q.PEAK DUO BLK ML - G10 400 UTILITY ACCT #:62665 - 24123 INVERTER: (1) SOLAREDGE INVERTER SE10000H-US (10 KW) RAFTERS: 2X6 @ 26" O.C. MAX SPAN: 10' - 2" 6" 10' - 2"1' - 4" 11' - 6" S2 NTS MP2 SIDE VIEW 1' 1' - 5" 4' - 6" 1X6@26" RAFTERS: 3X4 @ 26" O.C. MAX SPAN: 12' - 4" 6" 12' - 4"1' - 4" 13' - 8" S1 NTS MP1 SIDE VIEW 2" 2' - 5" 7' - 1" 2X4@26" 4X1@26" STANDOFF SCALE NTSS2 SOLAR MODULE RAIL L-FOOT QMSE-LAG SHINGLE COMPOSITE SHINGLE 5"X 5 16" - LAG 2.5" MIN. EMBEDMENT PER SCREW 2X6 NOMINAL 23' - 9" RAFTERS: 2X8 @ 16" O.C. MAX SPAN: 23' - 9" NTS MP3 SIDE VIEW STANDOFF SCALE NTSS1 SOLAR MODULE RAIL L-FOOT QMSE-LAG SHINGLE COMPOSITE SHINGLE 5"X 5 16" - LAG 2.5" MIN. EMBEDMENT PER SCREW 3X4 NOMINAL S3 Signed 2/3/2022 BREAKER FUSE SWITCH EARTH GROUND GEC EGC 1 AWG #6, THWN-2 AWG #8, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #6, THWN-2 AWG #6, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #10, THWN-2 AWG #10, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #10, PV WIRE AWG #10, THWN-2, EGC CONDUIT, 3/4" EMT ELEC. LEAD SIGN OFF: WIRE SCHEDULE 1 2 3 4 120/240V SINGLE PHASE OVERHEAD UTILITY SERVICE METER 23296139 100A/2P (E) LOADS 100A SQUARE D MSPGROUND ELECTRODE LINE SIDE TAP LINE LOAD 60A (N) 60A AC DISCONNECT - FUSIBLE, LOCKABLE - 60A FUSES 2 (N) SOLADECK JUNCTION BOX - UNFUSED -GROUNDED (N) (30) HANWHA Q.PEAK DUO BLK ML - G10 400 400W PV MODULES (30) SOLAREDGE P370 POWER OPTIMIZERS 1 BRANCH OF 11 1 BRANCH OF 11 1 BRANCH OF 8 (N) SOLAREDGE INVERTER SE10000H-US 3 4 INVERTER OUTPUT CURRENT(A)= INVERTER BACKFEED (A)= MSP RATING (A)= MAIN BREAKER RATING (A)= MAX BACKFEED (A)= TIE IN: 42 53 100 100 20 LST LINE (N)MA SMART METER METER SOCKET LOAD LEE, JOHN LEE RESIDENCE 212 SOUTH ST NORTHAMPTON, MA,1060 +1-413-426-1304 RACKING: IRONRIDGE XR-100 JOB NUMBER: 1135 UTILITY: NG OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 1/2/2022 PAGE NAME: PAGE: HA 10.00 kW AC SINGLE LINE PV5REVIEW BY: MS LINE LOAD 60A (N) 60A AC DISCONNECT - FUSIBLE, LOCKABLE - 60A FUSES 1 2 12.00 kW DC ROOF SOLAR SYSTEM MODULES: (30) HANWHA Q.PEAK DUO BLK ML - G10 400 UTILITY ACCT #:62665 - 24123 INVERTER: (1) SOLAREDGE INVERTER SE10000H-US (10 KW)