Beaver Brook Properties_Recharge Structures 12-2-21Assessors Parcel ID
06 -064-002
06 -064-003
06 -064-004
06 -064-005
06 -064-006
06 -064-007
06 -064-008
06 -064-009
06 -064-010
06 -064-011
06 -064-012
06 -064-013
06 -064-014
06 -064-015
06 -064-016
06 -064-017
06 -064-018
06 -064-019
06 -064-020
06 -064-021
06 -064-022
06 -064-023
06 -064-024
06 -064-025
11A-003-001
11A-003-002
11A-003-003
11A-003-004
11A-003-005
1Revised required recharge volume includes Beaver Brook Loop and additional as-built impervious totalling 3.62 acres
Property Address
58 CHESTNUT AV EXT
60 CHESTNUT AV EXT
62 CHESTNUT AV EXT
64 CHESTNUT AV EXT
66 CHESTNUT AV EXT
68 CHESTNUT AV EXT
70 CHESTNUT AV EXT
72 CHESTNUT AV EXT
74 CHESTNUT AV EXT
2 BEAVER BROOK LOOP
4 BEAVER BROOK LOOP
6 BEAVER BROOK LOOP
10 BEAVER BROOK LOOP
12 BEAVER BROOK LOOP
14 BEAVER BROOK LOOP
65 CHESTNUT AV EXT
63 CHESTNUT AV EXT
61 CHESTNUT AV EXT
67 CHESTNUT AV EXT
69 CHESTNUT AV EXT
71 CHESTNUT AV EXT
7 BEAVER BROOK LOOP
9 BEAVER BROOK LOOP
11 BEAVER BROOK LOOP
48 CHESTNUT AVE EXT
50 CHESTNUT AVE EXT
52 CHESTNUT AVE EXT
54 CHESTNUT AVE EXT
56 CHESTNUT AVE EXT
Loop Road
Loop Road
Unit #
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
1
2
3
4
5
Building
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Recharge Structure on 2021 As-Built Plan
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Type of Rechage Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
2 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
2 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
Stone Rechage Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
Stone Rechage Structure
Stone Rechage Structure
2 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
1 Drywell Recharge Structure
Small Infiltration Basin
Large Infiltration Basin
Constructed Recharge Volume (cf)
Original Required Recharge Volume (cf)
Revised Recharge Volume (cf)1
Constructed Volume (cf) of Recharge Structure
143
0
143
143
286
0
143
143
286
143
0
0
143
0
143
143
0
0
286
143
0
143
0
143
143
143
0
0
143
527
2976
6506
2178
3267
Total Impervious Area to Recharge Structures (sf)
Total Impervious Area (sf)
Percent of Impervious Area to Recharge2
Impervious Area (sf) Directed to Recharge Structure
1608
0
1780.75
484.8
1200
0
1078
2839
1895
2563
0
0
1818
0
1788
2497
0
0
1804
1898
0
2292
0
1780
358.75
478.375
0
0
478.375
1715
3824
28641.05
157687
0.18163228420859
Notes
Grate appears to have been recently buried. Nees to be located and inpected in next 5 years.
Has grated riser. No Downspouts tied in.
Has grated riser. 85% tied in.
Has grated riser. 30% tied in.
No risers
Has grated riser.
No inspection riser.
No inspection riser.
Has manhole riser.
No inspection riser.
No inspection riser.
No inspection riser. 60% tied in. Stone recharge volume unknown.
No inspection riser.
Has grated riser.
No inspection riser. Stone recharge volume is unknown.
No inspection riser. Stone recharge volume is unknown.
No inspection riser.
No inspection riser.
No inspection riser.
0
No inspection riser.
Grated riser. 25% overland flow to structure.
Grated riser. 50% overland flow to structure.
Grated riser. 50% overland flow to structure.
Roof Downspouts Connected Into Ground and to Drywell
Yes
No
Partially
Partially
Yes
House-yes, Outbuilding-No
Yes
Yes
Yes
No
Only 1
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
DPW Comment based on 10/6/21 inspection
Grated riser not found
Drywell not connected, no credit
OK
Ok
No riser for drywell in back of house
OK-needs to be located and inspected in next 5 years
OK-needs to be located and inspected in next 5 years
Ok
No credit unless more information submitted
OK-needs to be located and inspected in next 5 years
No credit unless more information submitted
OK
Ok
No credit unless more information submitted
No credit unless more information submitted
OK-needs to be located and inspected in next 5 years
OK-needs to be located and inspected in next 5 years
OK-needs to be located and inspected in next 5 years
No Credit, not connected
OK-needs to be located and inspected in next 5 years
OK
OK
Needs berm to collect flow
Add basin number. Can pretreatment be added? Must add to stormwater O&M plan to get credit. Add label to as-built plan.
Add basin number. Can pretreatment be added? Must add to stormwater O&M plan to get credit. Add label to as-built plan.
Volume meets recharge requirement
This is a very low percentage of impervious directed to recharge and would not meet current standards.