Loading...
A6 Andrews-Nason Res 9-14-214"1'-4 3/4"SECTION @ ADDITION Scale: 1/2" = 1'-0" 1 A6+/- 7'-8 1/2"BOT OF FOOTER MIN 48" BELOW+/- 6'-11 1/4"TOP OF CONCRETE TO BOT BEAM9'-0 1/2"DESIGNER:LEWKO KORZENIWSKY6343 Caton StreetPittsburgh, PA 15217(412) 654-7454 PROJECT:ANDREWS/NASON RESIDENCE105 Maynard RoadNorthampton, MA 01060(412) 443-2491ARCHITECT:DAVID SCHWING6343 Caton StreetPittsburgh, PA 15217(412) 654-7454 A6 9-14-21 PLOT SIZE 11"X17" SHEET NUMBER 20'-2 1/4" SPAN 20'-4" FACE OF STUDS TO CL OF POST +/- 7'-9 1/4"DOOR PANEL7'-8 3/4"SLOPE NEW CONCRETE FLOOR SLAB 1/8" PER FOOT 3/4" EXTERIOR GRADEAPA RATED PLYWOOD SHEATHING VERTICAL REINFORCING #5 REBAR @ 48" OC TIED INTO REINFORCING BARS IN FOOTER 4"X4" PT WOOD POSTS @ 48" OC BLOCKING FOOTER ON UNDISTURBED GRADE 3000 PSI CONCRETE FOOTINGW/ 2 CONTINUOUS #5 REBARS ON 3" CHAIRS MIN 3" FROM EDGE TERMINATION BAR& DRIP EDGE GRAVEL BACKFILL MIN 6" TOPSOILOVER BACKFILL GRADE RUBBER MEMBRANE ROOFSLOPE 1/4" PER 12" ALUMINUM GUTTER AZAK SOFFIT W/ CONTINUOUS SOFFIT VENT ROOF VENT IF REQ CUSTOM SCREEN DOOR PANELS FASTENED TO WOOD POSTS AS RECOMMENDED BY MANUFACTURER NEW BEAM DOUBLE 1-3/4X16 LVLTO BE SIZED BY STRUCTURAL ENGINEER SIMPSON SRONG-TIEPOST BASEPBS445AIMBEDED IN CONCRETE 12 0.25 MIN ROOF PITCH RUN ROOF MEMBRANE UP EXIST SLOPED ROOF MIN 18" TO PROTECT IN ICE DAM ZONE BLOCKING AS REQ NEW ROOF DECK TO BUTT INTO EXIST ROOF DECK 6/4 X 12 AZEK TRIM 1X6 AZEK TRIM 1X16 AZEK TRIM CUT IN FIELD AS REQ 21" SHEER WALL @ EACH EXTERIOR CORNER ALL STRUCTURAL MEMBERS SHALL BE SIZED BY REGISTERED PROFESSIONAL AS REQUIRED CUSTOM SCREEN DOOR TAPERED POLYISOCYANURATE INSULATIONMECHANICALLY FASTENED TO ROOF DECK TRUSS JOISTS TJI1560 @ 24" OC TO BE SIZED BY STRUCTURAL ENGINEER NEW PORCH FLOOR FLUSH WITH EXIST HARDWOOD FLOORING NEW PORCH FLOORING MATERIAL AS SELECTED BY OWNER V GROVE 48" X 96" PANELS WITH 1X4 PARTING BEADS ON CEILING DETAIL TO FOLLOW NEW BEAM W10 x12 STEEL BEAMTO BE SIZED BY STRUCTURAL ENGINEER 4" 3000 PSI CONCRETE SLAB W/ 6"X6"X10/10 WWM 4" GRAVEL FILL UNDISTURBED GRADE EXIST BLOCK FOUNDATION 3-1/2" DIA STEEL COLUMN W/STEEL PLATE ATTACHED TO NEW CONCRETE FOUNDATION W/ (4) 1/2" BOLTS EMBEDED 4-1/2" W/ EPOXY 6 MIL POLY VAPOR BARRIER EXIST ROOF FRAMING CURB MOUNTED SKYLIGHTS NEW 2x4 KNEE WALL TO SUPPORT NEW ROOF JOISTS REMOVE EXISTING BOTTOM PLATE STEEL PLATE BOLTED THRU BOTTOM FLANGE OF NEW STEEL BEAM REMOVE EXISTING BOTTOM PLATE EXISTING FLOOR JOISTS @ NEW DOOR OPENING CUT BACK AS REQ TO PROVIDE MIN BEARING OF 4" 3-1/2" DIA STEEL COLUMN NEW 2X4 BLOCKING FOR NEW MARVIN BI-FOLD DOORGLUED TO BOTTOM FLANGE OF NEW BEAM REMOVE EXISTING FRAMING AS REQ FOR NEW DOOR OPENING FILL EXISTING BLOCK CORES SOLID @ NEW DOOR OPENING RECESSED DOOR TRACK 1/2" AIR SPACE UNDER DOOR PANELSFILL W/ SCREEN MATERIAL TO KEEP INSECTS FROM ENTERING & TO ALLOW WATER TO DRAIN EXISTING 3/4" 1X6 WOOD SHEATHING W/ NEW 1/2" EXTERIOR GRADE DRYWALL