137 Elm Solar Application.pdfPermit Application
Please note: If this form sits idle for more than 30 minutes, you will have to start over.
A red bar to the left of a field name indicates the field is required.
A green bar indicates the requirement has been fulfilled.
Owner Information
Name |Justin Smith
Address |
City |Northampton
State |
Zip |01060
Applicant's Information
Same as property owner?
Is the applicant a City of Northampton
government department?|
Name |SunBug Solar LLC
Address |
City |Westfield
State |
Zip |01085
Phone |413-884-1000
Email |rachel.bruso@sunbugsolar.com
General Information
To complete the following section you will need the assessor's map-block-lot (##-##-###) and zoning district for all parce
project. If this project contains multiple parcels, please separate section-block-lot with semi-colons ";"
Click the following link to look up a map-block-lot number or zoning district:
Click here to look up a map-block-lot or zoning information
137 Elm St
66 Westfield Industrial Park Rd
Massachusetts
No
Massachusetts
How many lots will this project contain |1
Street Number of project |137
Street Name of project |
Choose City and Zip Code where proposed
work is located |
Registry of Deeds or Land Court deed book
and page number for work location |12269/125
Zoning Districts and Overlay Districts for
work location |Local Historic District
Assessors map # for work location |
Assessors block # for work location |
Assessors lot # for work location |
Permit Type
What PERMITS or AMENDMENTS are you applying for (check all that apply)
(NO application is complete until the fee is paid)
|||||||||||||||||||||||||||
Planning Bd. Special Permit w/ Site Plan - $325
Planning Bd. Special Permit w/ Site Plan for flag lots - $1,075
Planning Bd. Special Permit w/ MAJOR Site Plan NO Special Permit - $1,075 plus $0.05/sq. ft new building
Planning Bd. Site Plan (NO Special Permit) - $325
Administrative Site Plan Review - $100
Planning Bd. Major Site Plan or 40R Approval (No Special Permit) - $1,075 plus $0.05/sq. ft new building
Approval Not Required Plans - $250/plan page
Subdivision Preliminary - $600 plus $75 per unit
Subdivision Definitive IF Preliminary approved GREATER of $3000 or $10 linear foot of road
Subdivision Definitive IF NO Preliminary GREATER of $4600 or $14 linear foot of road
Subdivision Definitive Amendment - $500
Zoning Board Special Permit - $325
Zoning Board Finding - $325
Appeal of Building Commissioner-Zoning - $325
Comprehensive Permit (40B) - $1,075
Variance - $1,075
Demolition (Demolition Delay) - $200
Historic District Determination of Non-Applicability - $0
Historic District (Elm St) Determination of Appropriateness - $325
West Street Architecture - $200
Central Business Architecture - $325
Wetlands Notice of Intent, Abbreviated NOI or ANRAD, IF state wetlands (WPA Form 3, 4, or 4A) - $225 plus city sha
Wetlands Notice of Intent IF ONLY local wetlands (WPA Form 3) - $100 plus $100 per lot/building/unit
Wetlands Request for Determination OR Resource Delineation (WPA form 1 or 4a) - $175
Wetlands Amendment - $175
ELM ST
Northampton 01060
31B
167
001
Wetlands extension - $125
Wetlands Certificate of Compliance request - $0
Additional Information
Existing use of your structure or property |
Describe planned use, your proposed project
and your request in DETAIL (include relevant
sections of regulations) AND whether you
have discussed this with your neighbors
|
Fee amount: $325.00
Special Permit and/or Site Plan
Describe in detail how you meet ALL SEVEN requirements:
1. Will protect adjoining premises from seriously detrimental uses.
2. Will minimize and mitigate traffic impacts.
3. Promote a harmonious relationship of structures and open space.
4. Protect the general welfare.
5. Avoid overloading and mitigate impacts on City resources.
6. Promote city planning objectives (see Sustainable Northampton, Open Space Plan, and Transportation Plan).
7. Meet all zoning requirements.
Describe |
Historic District, Central Business Architecture and West Street Architecture
Describe in detail what you are requesting, how it meets the design manual and ordinance, and whether your work is:
1. New construction/new building?
2. An addition to an existing building?
3. An alteration of an existing building, including window and door replacement?
4. A demolition of an entire structure or a portion of a structure?
Describe
|
Residential
Install 15.58kW solar panels per designs attached on roof. (41 panels) It is highly un
that the system will be seen from the road. The structure of the home will not be alte
See attached designs and photos to represent this.
N/A
Install 15.58kW solar on roof, per attached designs. (41 panels)
Upload All Projects
Attach text and supporting information describing project as a multi-page TIF or PDF. If file size is too large, digital file m
submittal.
Upload Plan Sheets
Upload all plan sheets showing existing and proposed work as a multi-page TIF or PDF named 'plansheets.' If the file s
must be included with submittal.
Upload Historic
It is strongly advised that you include photographs showing your property, in TIF or PDF format, named 'historic.' If file s
file must be included with submittal.
Signature
By typing my name in the signature box, I certify that all the information above is accurate to the best of my knowledge,
or have permission from the property owner to apply for this permit. I also grant permission to the City of Northampton t
work.
Signature |Rachel Bruso
Date Signed
Submit Cancel
41 Panel Site Layout.pdf
plansheets.pdf
Historic.pdf
09/07/2021
0 40'80'
Scale:1" = 40'-0'
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPT
SUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLARLLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312
Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comPROPERTY PLAN
PROPERTY LINES
SETBACKS
LEGENDN
S
EW
1SATELLITE IMAGE SHOWN FOR REFERENCE ONLY. N.T.SEL
M
S
T
R
E
E
T ROUND HILL ROAD
M
AC
(E) UTILITY SERVICE METERS
(exterior, owner's is farthest left meter)
(N) AC DISCONNECT
(at owners Utility Meter)
(E) MAIN SERVICE PANELS
(basement, owner's is farthest right panel)
Envoy
(N) PV COMBINER
(basement, right of owner's MSP)
M M
MAC
(N) AC DISCONNECT
(basement, within 10ft of owner's MSP)
MP1- 196°az, 18° tilt
(12) LG380N1C-A6
(12) IQ7
MP2- 106°az, 27° tilt
(12) LG380N1C-A6
(12) IQ7
MP3- 196°az, 14° tilt
(11) LG380N1C-A6
(11) IQ7
MP4- 106°az, 14° tilt
(6) LG380N1C-A6
(6) IQ7
Scale: 3/32" = 1'
SITE PLAN
0 1'10'21'
M
Inv
DC
AC
LEGEND
UTILITY METER & WARNING LABEL
INVERTER & WARNING LABELS
DC DISCONNECT & WARNING LABELS
AC DISCONNECT & WARNING LABELS
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPT
SUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLARLLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312
Somerville, MA 02144
T:(617) 500-3938 F:(617) 412-3062
www.sunbugsolar.comSITE PLAN
N
S
E
W
2
MP1 - 196°az, 18°tilt
MP2 - 106°az, 27°tilt
MP3 - 196°az, 14°tilt
MP4 - 106°az, 14°tilt
(NOT RELATIVE LOCATION,
MOVED FOR SPACE)
20'-3"
16'-7"
29'-1"
31'-8"
14'-6"
15'
18'-1"35'-8"
9'-1"
25'-8"
10'-1"
4'-5"
21'-3"
14'-3"
24'-2"4'-11"
14'-11"
1'-8"
3'-5"
22'-1112"
5'-8"
2'-3"5'-212"
3'-812"
5'-812"
3'-5"
5'-812"
20'-812"
4'-1112"
4'-2"
11'-512"2'-912"
11'-512"2'-4"4'-412"11'-512"2'-012"
3'-5"
5'-812"
5'-812"
3'-5"13'-912"3'-5"
1"
23'-8"20'-812"
7"
2'-4"
1'-012"5'-812"2'-4"
6'
6'
1'-11"
N
S
E
W
LAYOUT PLAN
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPT
SUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLAR
LLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comCONSTRUCTION PLAN
CRITTER GUARDS
SNOW GUARDS
SERVICE UPGRADE
-MAX. RAIL SPAN VARIES BY SURFACE, SEE INDIVIDUAL MOUNTING PLAN
-MAX. RAIL OVERHANG 16"
POSITION MP3 ROOF ARRAY AS DIMENSIONED ON ROOF
POSITION MP1&2 ROOF ARRAYS TIGHT TO RIDGE ON ROOF
STRUCTURAL
REINFORCEMENT
N/A
SNR MID CLAMPS, END CLAMPS, RAIL SPLICES TORQUE TO 10FT-LBS
Roof to be replaced prior to installation. Easy roof to work on and can keep conduit outside betweenorphaned arrays. Open basement.
Run all conduit into attic of array 2 roof, out north side into basement on either side (see markup
image in GID). Attic of array 2 is accessible and workable.
Four meters, we want to tie into meter # 74520884, which is furthest to the left when facing themeters. Please confirm that is tied to to the correct meter. Four panels as well, owner's panel is
farthest right in basement.
Roof framing is different for each array, refer to individual mounting plan for specifics.
POSITION MP4 ROOF ARRAY CENTERED ON ROOF
PV COMBINER
AC DISCONNECT
MOUNT PV COMBINER IN BASEMENT NEAR MSP
INSTALL WITHIN 10 FT OF UTILITY METER AND INSIDE
WITHIN 10 FT OF TAP, MUST BE READILY ACCESSIBLE
N/A
INSTALL SNOW GUARDS AS SPECIFIED
N/A
NO REINFORCEMENT REQUIRED
-STAGGER STANDOFFS, SEE STRUCTURAL REPORT
-POSITION RAILS 7.9"(MIN.)-15.7"(MAX.) FROM EDGE OF MODULES IN PORT.
ROUGH ELECTRICAL INSPECTION REQUIRED
RAFTERS:TRUE 4X6 32" OC RAFTERS:TRUE 2x3.75" 20" OCMP1
INVISIBLE END CLAMPS
-POSITION RAILS 4.7" (MAX.) FROM EDGE OF MODULES IN LANDSCAPE
3
ATTACHMENT PLAN
ROOF FRAMING AND SURFACE DETAILS
ARRAY POSITION
ADDITIONAL WORK
SPECIAL PERMITTING
EQUIPMENT LOCATION
PROJECT NOTES
RAFTERS:2x6 16" OC RAFTERS:TRUE 3x5 18" OCMP2
MP3
MP4
SURFACE TYPE: ASPHALT SHINGLES (MP1-4)
16"32"
12"
12"
RAFTER
L-FOOT
FLASHINGPV MODULE TYP.
SNR MID CLAMP SNR RAILSNR END CLAMP
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 32"
RAIL POSITION 7.9"(MIN)-
15.7"(MAX) FROM PANEL EDGE
2
L-FOOT
FLASHING
SNR END CLAMP SNR MID CLAMPPV MODULE TYP.RAFTER
SNR RAIL
16"32"
4"
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 32"
RAIL POSITION 4.7"(MAX)
FROM PANEL EDGE
4"
2
TRU
E
4
x
6
R
A
F
T
E
R
S
@
3
2
"
O
.
C
.
T
Y
P
.
CO
M
P
O
S
I
T
I
O
N
R
O
O
F
3
6"
SNAPNRACK
L-FOOT
SNAPNRACK
ULTRA RAIL
5/16"X4" S.S. LAG SCREW
MIN 2.5" EMBEDMENT
SNAPNRACK FLASHING
SNAPNRACK
END CLAMP
OR UNIVERSAL
PV MODULE
ULTRA RAIL
MOUNTING
HARDWARE
MOUNTING PLAN -MP1
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPTSUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLAR
LLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comMOUNTING PLAN
RAIL POSITION PLAN VIEW 1
MOUNTING METHOD 2
MOUNTING DETAIL 3
0 2'1'
SCALE: 1" = 1'-0"
0 2'1'
SCALE: 1/2" = 1'-0"
0 8"4"
SCALE: 3" = 1'-0"
4
16"32"
12"
12"
RAFTER
L-FOOT
FLASHINGPV MODULE TYP.
SNR MID CLAMP SNR RAILSNR END CLAMP
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 32"
RAIL POSITION 7.9"(MIN)-
15.7"(MAX) FROM PANEL EDGE
2
2x6
R
A
F
T
E
R
S
@
1
6
"
O
.
C
.
T
Y
P
.
CO
M
P
O
S
I
T
I
O
N
R
O
O
F
3
6"
SNAPNRACK
L-FOOT
SNAPNRACK
ULTRA RAIL
5/16"X4" S.S. LAG SCREW
MIN 2.5" EMBEDMENT
SNAPNRACK FLASHING
SNAPNRACK
END CLAMP
OR UNIVERSAL
PV MODULE
ULTRA RAIL
MOUNTING
HARDWARE
MOUNTING PLAN -MP2
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPTSUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLAR
LLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comMOUNTING PLAN
RAIL POSITION PLAN VIEW 1
MOUNTING METHOD 2
MOUNTING DETAIL 3
0 2'1'
SCALE: 1" = 1'-0"
0 2'1'
SCALE: 3/4" = 1'-0"
0 8"4"
SCALE: 3" = 1'-0"
5
16"40"
12"
12"
RAFTER
L-FOOT
FLASHINGPV MODULE TYP.
SNR MID CLAMP SNR RAILSNR END CLAMP
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 40"
RAIL POSITION 7.9"(MIN)-
15.7"(MAX) FROM PANEL EDGE
2
L-FOOT
FLASHING
SNR END CLAMP SNR MID CLAMPPV MODULE TYP.RAFTER
SNR RAIL
16"40"
4"
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 40"
RAIL POSITION 4.7"(MAX)
FROM PANEL EDGE
4"
2
TRU
E
O
L
D
G
R
O
W
T
H
2
x
3
34" RA
F
T
E
R
S
@ 2
0
"
O
.
C
.
T
Y
P
.
CO
M
P
O
S
I
T
I
O
N
R
O
O
F
3
6"
SNAPNRACK
L-FOOT
SNAPNRACK
ULTRA RAIL
5/16"X4" S.S. LAG SCREW
MIN 2.5" EMBEDMENT
SNAPNRACK FLASHING
SNAPNRACK
END CLAMP
OR UNIVERSAL
PV MODULE
ULTRA RAIL
MOUNTING
HARDWARE
MOUNTING PLAN -MP3
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPTSUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLAR
LLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comMOUNTING PLAN
RAIL POSITION PLAN VIEW 1
MOUNTING METHOD 2
MOUNTING DETAIL 3
0 2'1'
SCALE: 1" = 1'-0"
0 2'1'
SCALE: 1/2" = 1'-0"
0 8"4"
SCALE: 3" = 1'-0"
6
16"36"
12"
12"
RAFTER
L-FOOT
FLASHINGPV MODULE TYP.
SNR MID CLAMP SNR RAILSNR END CLAMP
MAX. RAIL
CANTILEVER 16"
MAX. RAIL SPAN
BETWEEN L-FEET 36"
RAIL POSITION 7.9"(MIN)-
15.7"(MAX) FROM PANEL EDGE
2
TR
U
E
3
x
5
R
A
F
T
E
R
S
@
1
8
"
O
.
C
.
T
Y
P
.
CO
M
P
O
S
I
T
I
O
N
R
O
O
F
3
6"
SNAPNRACK
L-FOOT
SNAPNRACK
ULTRA RAIL
5/16"X4" S.S. LAG SCREW
MIN 2.5" EMBEDMENT
SNAPNRACK FLASHING
SNAPNRACK
END CLAMP
OR UNIVERSAL
PV MODULE
ULTRA RAIL
MOUNTING
HARDWARE
MOUNTING PLAN -MP4
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPTSUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,
WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLAR
LLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:3119-Wes-W
SnapNRack Ultra Rail Racking
(41) LG 380 NeON 2
(41) IQ7 Microinverter
15.58
UTILITY:NationalGrid
Smith, Justin
137 Elm St.
Northampton, MA 01060
(917) 301-8694
kW DC
MONITORING:Envoy
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comMOUNTING PLAN
RAIL POSITION PLAN VIEW 1
MOUNTING METHOD 2
MOUNTING DETAIL 3
0 2'1'
SCALE: 1" = 1'-0"
0 2'1'
SCALE: 3/4" = 1'-0"
0 8"4"
SCALE: 3" = 1'-0"
7
MODULES:
MOUNTING SYSTEM:
INVERTER:
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE USED FOR THE BENEFIT OF ANYONE EXCEPT
SUNBUG SOLAR LLC, NOR SHALL IT BE DISCLOSED
TO OTHERS OUTSIDE OF SUNBUG SOLAR LLC,WITHOUT CONSENT OR IN CONNECTION WITH THE
SALE AND USE OF THE RESPECTIVE SUNBUG SOLARLLC SYSTEM
JOB REFERENCE:SYSTEM SIZE:
SHEET TITLE:
OWNER:
UTILITY:
kW DC
MONITORING:
REVISIONS
DESCRIPTION:DATE:REV:
SHEET NUMBER:SHEET SIZE: 11"x17"
7/29/2021 1Original
BY:
NB
7/30/2021 1.1FC Edits ML
411A Highland Ave, Suite 312Somerville, MA 02144T:(617) 500-3938 F:(617) 412-3062www.sunbugsolar.comSTRING DIAGRAM 8
BRANCH CIRCUIT 1 - 6 MODULES
BRANCH CIRCUIT 2 - 12 MODULES
BRANCH CIRCUIT 3 - 12 MODULES
BRANCH CIRCUIT 1 - 11 MODULES