CS 16 ft Beam CalcCS Beam 2020.3.0.31 kmBeamEngine 2018.9.0.1 Materials Database 1582 Dan Odell 33 Avis Circle Florence 8-31-21 9:56am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. Member Data Description:Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: 0.00 Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 4.4 PLF Filename: Beam1 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 16' 0.00" 6' 0.00" 40 10 Live 1 2 3 4 5 4 0 0 4 0 0 4 0 0 4 0 0 16 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.500" 503# -- 2 4' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.674" 1419# -- 3 8' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.580" 1339# -- 4 12' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.674" 1419# -- 5 16' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.500" 503# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 408# 95# 2 1135# 284# 3 1094# 245# 4 1135# 284# 5 408# 95# Design spans 3' 9.375" 4' 0.000" 4' 0.000" 3' 9.375" Product: SYP (PT MCA) #1 2 x 12 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes maximum unbraced length of 0.00' along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 416.'# 2637.'# 15% 14.08' Even Spans D+L Negative Moment 535.'# 2637.'# 20% 4' Adjacent 1 D+L Negative Unbrcd 535.'# 2637.'# 20% 4' Adjacent 1 D+L Shear 432.# 1969.# 21% 3.24' Adjacent 1 D+L Max. Reaction 1419.# 3284.# 43% 4' Adjacent 1 D+L LL Deflection 0.0028" 0.1260" L/999+ 13.89' Even Spans L TL Deflection 0.0032" 0.1891" L/999+ 1.92' Odd Spans D+L Control: Max. Reaction DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2012