Loading...
report 47 Ladyslipper Lane Northampton, MAInstaller's Name:Scott Carli Installation Checklist Franchisee Location:Connecticut Installation Equipment: GoliathTech Calibrated Hydraulic Drill with PSI Gauge Torque Indicator Installation Date:6-23-21 Name of Customer or Contractor:Classic Colonial Homes Description of customer project:Addition Project Address:47 Ladyslipper Lane Northampton, MA Pile Number Required Compression Capacity Required Torque Pile Used Helix Used Total Pile Depth (if not 7') Cut-off Elevation (if not 8" +-2) Inclination of Pile (if not 90 Degrees +-2)PSI Torque Achieved Achieved Compression Capacity Achieved Tension Capacity 1 2 3/8 9 900 2400 12000 6000 2 2 3/8 9 900 2400 12000 6000 3 2 3/8 9 900 2400 12000 6000 4 2 3/8 9 900 2400 12000 6000