23A-025 (5) 35 PARK ST BP-2022-0032
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block:23A-025 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove - BUILDING. PERMIT
Permit# BP-2022-0032
Project# JS-2022-000055
Est.Cost:
Fee: $40.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: THE FIRE PLACE 99401
Lot Size(sq. ft.): 14941.08 Owner: LURIA SARA
Zoning:URB(100)/ Applicant: THE FIRE PLACE
AT: 35 PARK ST
Applicant Address: Phone: Insurance:
P 0 BOX 606 (413) 397-3463 () WC
WHATELYMA01093 ISSUED ON:7/12/2021 0:00:00
TO PERFORM THE FOLLOWING WORK:PELLET STOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
i 9-1
Certificate of Occupancy signat • �� ; , yQ •
•
FeeType: Date Paid: Amount:
Building 7/12/20210:00:00 $40.00
212 Main Street, Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
City of Nort p an
0
Jf/ Massachusetts A�/ �•} j!rt
l r i raj D .,! �; 9 t9 j "k€
',�.�,r 7} ':;, �y DEPARTMENT OF BUILDING INSPE 'T%�>• A-1 `r�, ;�
V 4'tk ;_` 212 Main Street • Municipal Build�� �� fib`.,.
\ y }+ ram, p Q 2 t''
� Northampton, MA 01060 O,LG'i�, 4 jr . ,,.o
S
A
,�\ 'ty,90 ACT
,\ %°l
APPLICATION FOR SOLID FUEL APPLIANCE INS A ATION
;Property Information
Owners Name: \f',,ra.. L,r t(-:
Address: &r `/)(r/< <S - /®refrcc Ou el) and
(No.) (Street Address)
Phone: /94S� oa37
Cell: Email:
•
Owners Signature: > Date: ��
Contractor's Information (If Applicable)
;Name: iDevyieq L fh -- `7 /�i-%�/�CC_ Phone: 4ri•-:-' 7. c4'
,Construction Supervisor's License #: 9?5(0/ Expiration: /6-a�
Home Impr. Contractor License #: / IC 5e 77 Expiration: ///J a
Stove Information
;Type of Fuel (check all that apply): Wood Pellet V Coal
'Location: ,'rs4 1-/6rr.- Freestanding V Insert
Manufacturer: f rni Model: d6 6-o/e✓, 4
_ FOR BUILDING DEPARTMENT USE ONLY ----------J- -----_________
Permit# 1 0''a !t- Date Applied: Total all Fees: $ ` O C12 C'1
Building Official: Date Issued: 7 ) D
F' � 0, /
Signature of Building Official: rc ; �j! : 1 ,
i I ,
•
The Commonwealth of Massachusetts
Department of Industrial Accidents
'77-7 Office of Investigations
.� 1�s
I , .— Lafayette City Center
2 Avenue de Lafayette,Boston,MA 02111-1750
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: General.Businesses
Applicant Information Please Print Legibly
Business/Organization Name:THE FIRE PLACE
Address: 100 STATE RD
City/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463
Are you an employer?Check the appropriate box: Business Type(required):
I.El I am a employer with 10 employees (full and/ 5. ❑ Retail
or part-time).* 6. ❑ Restaurant/Bar/Eating Establishment
2.❑ I am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl.real estate,auto,etc.) •
employees working for me in any capacity.
[No workers' comp. insurance required] 8. El Non-profit
3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment
their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing
no employees. [No workers' comp. insurance required]** 11.11 Health Care
4.❑ We are a non-profit organization, staffed by volunteers,
with no employees. [No workers' comp. insurance req.] 12.0 Other
*Any applicant that checks box"#I must also fill out the section below showing their workers'compensation policy information.
**If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an
organization should check box 41.
I an:an employer that is providing workers'compensation insurance for my employees. Below is the policy information.
Insurance Company Name:MA RETAIL MERCHANTS WC GROUP INC
Insurer's Address:P.O. BOX 859222-9222
City/State/Zip: BRAINTREE, MA 02185
Policy#or Self-ins. Lic.#01400503301116 Expiration Date: 1-1-22
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under§25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up
to$l,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to
$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations•of
the DIA for insurance coverage verification.
I do hereby certi 31;under the pains an penalties of perjury that the information provided above is true and correct.
Signature: .ter , Date:
Phone#: /— j l ,V 3
Official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License#
Issuing Authority(check one):
1.DBoard of Health 2.0 Building Department 3.0 City/Town Clerk 4.❑Licensing Board
5.0 Selectmen's Office 6.['Other
Contact Person: Phone#:
www.mass.gov/dia
. _
3 Clearances
• A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only.
t
, mom I= . . ilril
,\-1==r
•
•
. , _ _ _
N I
li.
gc E'' i
IA]
•
. .,.,
* .
24-9/16" -• s
a it r j ' 1-1/4„
i •
g 1\\. /1 1 _ i___i —
•1 -
• • Outside Air \/ -
eu0OH 011 HERO Intake o Pie
• II
• i t4 _ r- I tpaq s. -',,) !--_T.
cNi
; O
_ 4,,_4
. (qt;, En
fa., , . c_i.;40,11_,Iaismi . , 4.:
. „: ..,: .. . -i- ......... --c6
6-1/8"
Figure 3.1
Y
7 Harman® • Absolute43 Installation Manual R9 •• 2015- • 08/17 3-90-00778i
h
B. Non-Combustible Materials Specification —
Material which will not ignite and burn. Such materials are I
those consisting entirely of steel, iron, brick, tile, concrete, — 2" 11_71/m)
slate, glass or plasters, or any combination thereof. .
Materials that are reported as passing ASTM E 136, " ,
Standard Test Method for Behavior of Materials in ° En,
J °
a Vertical Tube Furnace at 750° C and UL763 shall be
considered non-combustible materials. 0 6"(152mm)
C.•Combustible Materials Specification
Materials made of or surfaced with wood, compressed 4 �J .
paper, plant fibers, plastics, or other material that can ignite
and burn,whether flame proofed or not, or plastered or un-
plastered shall be considered combustible materials.
D.'.Clearances to Combustibles 6"(450mm)
When selecting a location for the appliance it is important to
consider the required clearances to walls(see Figure 3.2).
• A WARNING . , -- 1
6.25"
RISK OF FIRE OR BURNS! Provide adequate (159mm)
clearance around air openings and for service `\
access. Due to high temperatures, the appliance should
be located out of traffic and away from furniture and
draperies. f
tip/
NOTICE:Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.Actual installation may vary due \
to individual design preference. n
Place the stove away from combustible walls at least as far
as shown in Figure 3.2.
Note that the clearances shown are minimum for safety but do
not leave much room for access when cleaning or servicing.
Please take this into account when placing the.stove.
NOTE: Top of unit must be a minimum of 12"(305mm)to
When installing the unit into an alcove..it is important to ceiling
consider the required clearances listed below. -- -- - -
Figure 3.2
I■■■■■■■■■■■■■■■■■■ A CAUTION
■■■■■■■■■■.EEE■E■■■
�I■■■■■■ - I..-
THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE.
MI
■■■I��� NOTICE: Clearances may only be reduced by means
�: _ '•l approved by the regulatory authority having jurisdiction.
I■I `* UN Due to high temperatures,the stove should be placed away
:■ i N from traffic,furniture and draperies.
■■ 36"Wide IMO Children and adults should be alerted to the hazards of high
i.i NMI surface temperatures and should stay away to avoid burns
■■ INN to skin and/or clothing.
M� poi Young children should be carefully supervised when they are
� ' in the same room as the stove.
Height=42",Width=36,Depth=24" Clothing and other flammable materials should not be placed
on or near this unit.
8 Harman® • Absolute43 Installation Manual_R9 • 2015- • 08/17 3-90-00778i
E. Floor Protection Corner Installation:
Parallel Installation: Minimum size floor protection for a corner installation hearth
Place the stove on a noncombustible floor or floor protector pad is 25-7/8"Wide By 28 Deep(658mm X 711mm). Note:
that extends a minimum of 6 inches (152mm) to the front Floor protector WILL NOT touch the wall using minimum
of the load door opening, 6 inches (152mm)to the sides of clearances.
the door opening, and 1 inches to the rear. Floor protection If corner floor protection is desired to touch the wall,the floor
must also extend 2 inches(51mm)beyond each side of any protection will need to be at least 36"x 36"(914mm x 914mm).
horizontal flue pipe. The minimum floor protector material Note:This will allow the floor protection to touch the wall
is 20 gauge sheet metal. Other floor protector materials are as shown.Figure 3.4.
ceramic tile, stone, brick, etc. Alternate floor protector dimension may be used as long as
Minimum Size floor protection is 25-7/8" wide By 28" deep they satisfy the measurement requirements shown below.
(658mm X 711mm). Figure 3.3
FLOOR PROTECTOR
if41-0 I I o o.V "C`
°
G>
NAOP-
J ,
FLOOR PROTECTOR
K Figure 3.4
Figure 3.3 F. Mobile Home Installation
When installing this unit in a mobile home, several
Floor Protection requirements must be followed:
Requirements 'US Canada 1. The unit must be bolted to the floor. This can be done
using an appropriate fastener for the application.
J Sides 6" 152mm 2. The unit must be connected to an outside combustion
K Front 6" 152mm air inlet. Proper supports and spark arresters must be
L Rear 1" 25mm considered when installing venting. See "Termination
Location and Vent Information" Section D.
3. Floor protection and clearances must be followed as
shown.
4. The appliance must be properly grounded to the frame of
the mobile home using a minimum of 8 AWG copper solid
or stranded, insulated or bare wire or equivalent.
Install 1/4"lag bolts here.
Figure 3.5
9 Harman® • Absolute43 Installation Manual R9 • 2015- • 08/17 3-90-00778i
..
4 Termination Location and Vent Information
A. Vent Termination Minimum Clearances
#1 Preferred method(Figure 4.1)
This method provides excellent venting for normal operation
and allows the stove to be installed closest to the wall.Two
inches from the wall is safe; however, four inches allows
better access to remove the rear panel.The vertical portion of
the vent should be three to five feet high.This vertical section
will help provide natural draft in the event of a power failure.
Seal pipe joints with silicone or aluminum tape in addition to
the sealing system used by the manufacturer.
/r11� Note: Do not place joints within wall pass-through.
��;:`."` 3 Ft. THE CHIMNEY MUST BE OF A TYPE SUITABLE FOR
1; to SOLID-FUEL BURNING.
Combustibles
_ -� A WARNING
THE CHIMNEY AND CONNECTOR MUST BE
MAINTAINED IN GOOD CONDITION AND KEPT CLEAN.
ft g1 V
,
— ....-10% JI------n-ri i,:„. i - ,
A CAUTION
to Combustibles DO NOT.USE MAKESHIFT COMPROMISES WHEN
INSTALLING THIS APPLIANCE. DAMAGE AND/OR
Figure 4.1 INJURY MAY RESULT.
\ _`-', #2 Preferred method (Figure 4.2)
This method also provides excellent venting for normal
operation but requires the stove to be installed farther from
the wall. The vertical portion of the vent should be three to
. five feet high and at least 1" from a combustible wall. This
vertical section will provide natural draft in the event of a
power failure.
Seal pipe joints with silicone or aluminum tape in addition to
the sealing system used by the manufacturer.
( .1_.__._J.
,.. ,- If the stove is installed below grade be sure the vent
3 Ft. termination is at least 12" above grade (with outside air
to only). The outlet must also be 1 foot from the house/building.
„` Combustibles
Note:Do not place joints within wall pass-through.
..., : ,
;I., ., ,
T, =T
A CAUTION
4 Keep combustible materials (such as grass, leaves,
etc.) at least 3 feet away from the flue outlet on the
_ '„,..aodi .,,, outside of the building.
-E 0-
3 Ft.
to Combustibles
Figure 4.2
10 Harman® • Absolute43 Installation Manual_R9 • 2015- • 08/17 3-90-00778i