Loading...
13-099 (8) 96 COLES MEADOW RD BP-2021-1551 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 13-099 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: gas fireplace BUILDING PERMIT Permit# BP-2021-1551 Project# JS-2021-002575 Est.Cost: $677 3.00 Fee: $65.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: CORY MCGILL DBA DONE RIGHT CHIMNEY SERVICES 107658 Lot Size(sq. ft.): 80411 .76 Owner: CHAFFEE RUFUS J&JOAN L Zoning: Applicant: CORY MCGILL DBA DONE RIGHT CHIMNEY SERVICES AT: 96 COLES MEADOW RD Applicant Address: Phone: Insurance: PO BOX 1054 (413) 340-1399 W ILLIAMSBURGMA01096 ISSUED ON:6/29/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:BUILD GAS FIREPLACE WITH SURROUNDING HEARTH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. 1IcAt. Certificate of Occupancy Signature: • • " qf� FeeTvpe: Date Paid: Amount: Building 6/29/2021 0:00:00 $65.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner AFC lr JIM &C The Commonwealth of Massachu'•-•.s• 8 >�Y it Board of Building Regulations and Stan ���� i/t. ���, LITY Massachusetts State Building Code, 780 1/pTON inspF Building Permit Application To Construct,Repair,Renovate Or k 'g»,ys Rar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: _6,d`i-/. S j Date Applied: // /ir.)(ZS) 6-2.4.20zi Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map Sc.Parcel Numbers 96 Coles Meadow Road 1- d/I 1.1 a Is this an accepted street?yes no Map Number Parcel Num er 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public ID Private 0 Zone: — Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIPt 2.1 Owner'of Record: Joan & Rufus Chaffee Northampton, MA 01060 Name(Print) City,State,ZIP 96 Coles Meadow Road 413-478-0760 chaffee050@comcast.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK=(check all that apply) New Construction Cl Existing Building 0 Owner-Occupied ❑ Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Other X Specify: Framing Gas Fireplace Brief Description of Proposed Work':To Frame in a gas fireplace, with surrounding hearth and tile face, to mount and prep unit for electrician to wire, and plumber to vent and run gas line to. To finish off unit and wall with Hardy Board and tile. Gas unit will be a Regency Excalibur P9OE gas fireplace, framing and vent requirements attached-d, 4P12oPr►►.Jc SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 6,773.88 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 0 Standard City/Town Application Fee 375.00 ❑Total Project Costs(Item 6)x multiplier x 3.Plumbing $ 825.00 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Feis:,$� / ,� Check No. Check Amour.0 Cash Amount: 6.Total Project Cost: $ 6,773.88 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES S Zy- Z02.3 5.1 Construction Supervisor License(CSL) CS-107568 0.57"25t202-1 Cory McGill License Number Expiration Date Name of CSL Holder List CSL Type(see below) U P.O. Box 1054 No.and Street Type Description Williamsburg, Ma 01096 U Unrestricted(Buildings up to 35,000 Cu.ft) g R Restricted 18.2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-340-1399 Donerightchimneyservices@gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) Cory McGill 178722 08/27/2022 1:I1C Registration Number Expiration Date HIC Company Name or HIC Registrant Name P.O. Box 1054 Donerightchimneyservices@gmail.com No.and Street Email address Williamsburg, Ma 01096 413-340-1399 City/Town,State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes X No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHJ.N OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property, hereby authorize Cory McGill to act on my behalf,in all matters relative to work authorized by this building permit application. 5/Print Owner's Name Electron is Signature) 26D4tE " 1 SECTION 7b: OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below.I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Cory McGill 0001 Print Owner's or Authorized Agen a(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. I42A_Other important information on the HIC Program can he found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" ego* The City of Northampton e�3--.4. .- Building Department 212 Main Street 44E030»E Northampton, Massachusetts 01060 Phone (413) 587-1240 Fax (413) 587-1272 CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVAT ION PROJECTS) In accordance with the provisions of MGL c40, s54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility as defined by MGL c 111, s150A. The debris will be disposed of in: Valley Recycling Location of Facility 234 Easthampton Rd, Northampton, MA 01060 The debris will be transported by: Name of Hauler Cory McGill Signature of Applicant: "la-"at. Date: 57Wajal The Commonwealth of Massachusetts ► ""* 1. Department of Industrial Accidents mil` 1 Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/individual): Done Right Chimney Address: P.O. Box 1054 city/state/zip:Williamsburg, Ma 01096 Phone#:413-340-1399 Are you an employer?Check the appropriate box: Type of project(required): 1.❑I am a employer with employees(full and/or part-time)." 7. ❑New construction 2.13Z1 I am a sole proprietor or partnership and have no employees working for me in 8. Remodeling any capacity.[No workers'comp.insurance required.] 9. ❑Demolition 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.] 10 Q Building addition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.0Roof repairs These sub-contractors have employees and have workers'comp.insurance.: 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14. Other Framing Gas Fireplace 152,§1(4),and we have no employees.[No workers'comp.insurance required.] "Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins.Lic.#: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify 0,1/"4,_„ unnder the pains and penalties of perjury that the information provided above is true and correct: Signature: Date: Phone#: 13-340-1399 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: dimensions unit Dimensions r 31" I — 1 (786mm) 1 — 11 0 0 0 0 I i 0 -!... L 21-11/16" i (550mm) 35-1/8" (891 mm) 42" (1067mm) 8-5/16" (210mm) 3-3/8", (86mm) /\ i 1 1----1 . . £ .t to 0, I t 0 4 0 .i. p N vE M DE E D_ • � � � � Nr- . co� fen E c Cco at,- N (D N N tt • ' . a • G® t • ' .... _ . . . • (11-1/8"A ► 37" •1 (29mm) (940mm) 22-1/2" (570mm) (Without Faceplate) UJ Gas connection is from the righthand side of the appliance&electrical connection on lefthand side of the appliance. O A metal receptacle box is supplied/installed with the appliance to make all 120 volt electrical connections. ALL PICTURES/DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency Excalibure P90E-11 Direct Vent Gas Stove I 5 safety decal This is a copy of the label that accompanies each P90E-11 Zero Clearance Direct Vent Gas Fireplace.We have printed a copy of the contents here for your review.The safety label is located on the front inside base of the unit,visible when the bottom louver is open. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference,the label on the unit is the correct one. • Copy of Safety Decal for P90E-11 1 1 DUPLICATE SERIAL NO. 496 I 1 1 'r Listed/Nom:VENTED GAS FIREPLACE /FOYER AU GAZ A EVACUATION DO NOT REMOVE THIS LABEL/NE PAS ENLEVER CETTE ETIQUETTE �- Certified to/Certlfid: ANSI Z21.88-2017•CSA-2.33-2017 Serial No./No de aerie c I us CSA 2.17-2017 REGENCY® MAY BE INSTALLED IN MANUFACTURED(MOBILE)HOMES AFTER FIRST SALE. R .• 496 Intertek Refer to Intertek's Directory of Building Products for detailed information. C#:4001172 Pour plus de details,se reporter au Repertoire des prodults de construction de Intertek. --- ---• O --- NATURAL GAS:Model P90E-NG11 APPAREIL FONCTIONNANT AU GAZ NATUREL Minimum Clearances to Combustibles Models P90E-NG11 Odgagaments minimaux par rapport aux matdrlaux combustibles '0 i Minimum supply pressure 5" WC(1.25 kPa) Pression d'alimentation minimale c o Manifold pressure high 3.5" WC(0.87 kPa) Presslon manifold-haute 44"To Calling 0"Clearance to m m Manifold pressure low 1.6" WC(0.40 kPa) Pression manifold-basse combustibles from: k Orifice size #34 DMS Taille de('orifice 4 ♦ Top,bottom,sides&rear of unit .1 s Minimum Input 23,500 Btu/h(6.89 kW) Debit calonfique minimal r m- Maximum Input 35,000 Btu/h(10.26 kW) Debit calonfique maximal Is" Mantel Clearances from Top: .. Attitude 0-4500 ft/pi (0-1372 m) Altitude i Min,19"(483mm) O PROPANE:Model P90E-LP11 APPAREIL FONCTIONNANT AU GAZ PROPANE gg Side Wall Clearance �s•1/z". e•tr2" - from Side Facing Models P90E LP11 3 4 ` 6-112"(I6i65mmmm) o Minimum supply pressure I t' WC(2.74 kPa) Pression d'alimentation minimale 0 o Manifold pressure high 10" WC(2.49 kPa) Pression manifold-haute Alcove Clearances: o aMax.Depth 36" 914mm) m m Manifold pressure low 8.4" WC(1.60 kPa) Pression manifold-basse Min.Width 72" 1829mm), r-— Orifice size #51 DMS Taille de!Orifice 11 II Min.Height 72" 1829mm) a o Minimum input 25,500 Btu/h(7.47 kW) Debit caloilfque minimal Minimum Vent Clearances: -'a Maximum input 31,500 Btu/h (9.23 kW) Debit calorifique maximal 7 - \ Horizontal Top 2-1/2"(64mm N. Altitude 0.4500 tug(0-1372 en) Altitude (see Instruction Manual for Horizontal Side 1-1/2'(38mm Detailed Instructions) Horizontal Bottom 1-1/2"(38mm DOOR SEAL: Please check that the door is properly sealed This appliance must be installed in accordance with local codes,if any;if none,follow the National Fuel Gas Code,ANSI 2223.1,or Natural Gas and Propane Installation Code,CSA 8149.1. This appliance must be installed In accordance with the Standard CAN/CSAZ240 MH,Mobile Housing,in Canada,or with the Manufactured Home Construction and Safety Standard,Title 24 CFR,Part 3280,in the United States,or when such a standard Is not applicable,ANSI/NCSBCS A225.1/NFPA 501 A,Manufactured Home Installations Standard orANSI A119.2 ou NFPA 501 C Standard for Recreational Vehicles This appliance Is only for use with the type of gas Indicated on the rating plate and may be installed in an aftermarket,permanently located,manufactured(mobile)home where not prohibited by local codes.See owner's manual for details.Optional Fan(Part#910-331) Optional Heat Wave Kit#946-556 Optional Heat Release Kit#946-570 Installer l'appareil salon lea codes ou reglements locaux,ou,en('absence de tels reglements,salon les codes d'installation ANSI Z223.1,National Fuel Gas Code ou CSA-B149.1 en vigueur. Installer l'appareil selon la norme CAN/CSA-Z240,Serie MM,Maison mobiles ou CAN/CSA-Z240 VC,Vehicules de camping,ou la norme 24 CFR Part 3280,Manufactured Home Construction and Safety Standard.SI ces normes ne soot pas pertinentes,utiliser la norneANSI/NCSBCS A225.1/NF PA501 A,Manufactured Home Installations Standard,ou ANSI A119.2 ou NFPA501 C Standard for Recreational Vehicles. Cet appareil dolt etre utilise uniquement avec le type de gaz indique sur la plaque signaletique.Cet appareil peut etre installs dans une malson prefabriquee ou mobile(E.-U.seulement)Installee a demeure si les reglements locaux le permettent,Voir le manuel d'utilisation pour plus de renseignements.Cet appareil ne peut pas etre utilise avec d'autres gaz sauf si une trousse de conversion certifies estfoumie. This vented gas fireplace heater la not for use with air fitters. Ne pas utiliser de(litre a alr avec ce foyer au gaz a evacuation. For use with glass doors certified with the appliance only A utiliser uruquamentavecles sodas en verrs certifies%avec l'appareil For Use Only with Barrier(Pert#792.920)Follow installation Instructions. Utiliser uniquement avec l'ecren(piece n°7924120)Suivre lee consignes d'installation. ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:115V-60HZ less than/moins de 2 AMP FPI Fireplace Products International Ltd. VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUELS. Delta,BC,Canada FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. Made in Canada/Fabnque au Canada CANAVAN ENERGY VERFIEO _ICSA P.4.1 Fireplace Efficiency(FE)/EfTcacite energetique des foyers(EEF)CSA P.4.1 Natural Gas/Gaz natural 71.36% Intertek EeEa r c'iE Propane Gas I Gaz propane 72.79% 919-970 EP6011169 VERFe For the State of Massachusetts,installation Decal location, and repair must be done by a plumber or .: — Fold down access door by flipping down 90° once you gasfitter licensed in the Commonwealth of have gained access the rating plate will be located on the Massachusetts. l left hand side(see image below). For the State of Massachusetts,flexible con- DO NOT REMOVE DECAL FROM UNIT. nectors shall not exceed 36 inches in length, °' For the State of Massachusetts,the appli- ances � .,„--•-!' j N individual manual shut-off must be a t-handle type valve. ' The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm ;,r 14. with battery back up in the same room where the gas appliance is installed. • • • 6 I Regency Excalibur®P90E-11 Direct Vent Gas Stove installation Locating Your Manufactured Mobile Home Clearance to Combustibles from: Gas fireplace Additional'Requirements Sack 0" (0mm) Side 0" (Omm) Floor 0" (0mm) 1. When selecting a location for your fireplace, 1. Ensure that structural members are not cut or (below firebox base) ensure that the clearances outlined on this weakened during installation. page are met. 2. Ensure proper grounding using the #8 ground 2. Provide adequate clearances for servicing. lug provided.See the"Wiring Diagram"section. NOTE:The minimum floor clearance must be maintained from the top surface of the 3. The appliance must be installed on a flat,solid, carpeting,tile,etc. continuous surface(e.g.wood,metal,concrete). '=41440wil'e--''''IttaSee Hearth Requirements in this manual. This may be the floor,or raised up on a platform Heat Wave to enhance its visual impact.If the appliance isAtitmovw ,, - going to be installed on carpeting,combustible P linoleum tile or other combustible material other Min.18-7/8" 4 than wood flooring, the appliance must be HeatWave Duct System (4.7emm) -. 0 installed on a metal or wood panel extending Optional Kit #946-556 E the full width and depth of the appliance. E The Heat Wave Air Duct Kit increases the 4. The P90E-11 Direct Vent Gas Fireplace effectiveness of your fireplace by dispersing warm can be installed in a recessed position or air from the fireplace to remote locations in the same Min. E framed out into the room as in A, B, C, D. room or other rooms in your home. 6-1/2" A 1 See Diagram 1. (165mm ; C o 4 0- Up to two kits may be installed on the fireplace. Please Note:Only 1 HeatWave kit may be operated — N at one time. This includes the internal blower option as well. T B A Side Wall Clearance 6-1/2"(165mm) r A) Flat on Wall 1- : c B) Flat on Wall Corner Horizontal Vent Clearances Li\ C) Recessed into Optional Top 2-1/2"(64mm) D Wall/Alcove Heat Release Kit Side 1-1/2"(38mm) I _ \ D) Corner #946-570 Bottom 1-1/2"(38mm) Diagram 1 The Heat Release Kit expels warm air from the Vertical Vent Clearances 1-1/4"(32mm) fireplace to the outside of the building, allowing Alcove Clearances**: the fireplace to be operated with less heat entering Max.Depth 36" (914mm) 5. This appliance is Listed for bedroom installations the room.The kit may be used on either the left or when used with a Listed Millivolt Thermostat. right side. Min.Width 72" (1829mm) Some areas may have further requirements, Min.Height 72" (1829mm) check local codes before installation. see mantle clearance instructions 6. The P90E-11 Direct Vent Gas Fireplace is Clearances (Refer to the"Combustible Mantels"section). approved for alcove installations,which meet The clearances listed are Minimum distances unless the clearances listed on this page. otherwise stated: WARNING: 7. We recommend that you plan your installation on Fire hazard is an extreme risk paper using exact measurementsforclearances Amajorcauseofchimneyrelatedfiresisfailure if these clearances are not and floor rotectionbefore actuall installingthis to maintain required clearances (air space) adhered to. p y to combustible materials. It Is of the greatest appliance.Have a qualified inspector,dealer,or importance that this fireplace and vent system installer review your plans before installation. be installed only in accordance with these Note: For vent terminations see the instructions. Clearances for HeatWave and "Exterior Vent Termination Heat Release Kit Locations" section. H 1 Heat Release Kit The HeatWave Duct Kit and the Heat Release Kit have different clearance and framing requirements,check the HeatWave and Heat Release manual for details. 16 I Regency Excalibur®P90E-11 Direct Vent Gas Stove installation Unit Base Standoffs Framing and Finishing 1. Determine the total thickness of facing To accommodate varying thicknesses and finishes Insert the 2 unit base standoffs underneath material(e.g.drywall plus ceramic tiles)to of hearth materials,we have increased the overall the unit as shown in the diagram below.Space allow the finished surface to be flush with height of the appliance by a further 1 1/8".This the standoffs centrally,approximately 2 or 2-1/2 the front of the unit.Total facing thickness increase is added with the inclusion of two stand- feet apart.Ensure that the unit is not unstable. can vary from 1/2"(13mm)to 3-3/8"(86mm) offs at the bottom of the unit,below the outer box, p +� thick. taking the overall height of the framing dimensions from 45-1/4"up to 46-3/8". Alt Non-combustible In the event that you should choose to use thinner material 7"(178mm) extends a materials to finish the hearth, you can omit the Standoff standoffs provided for raising the unit.However,we minimum of ! 18-7/8"(479mm) 1 Top of unit recommend that you leave the framing dimensions above the �( as theyare in the manual and alter onlythe facingJir R ^ front opening , requirement by reducing it by the same distance %�� � t,� ���'" that you have lowered the unit. l i C Install Top Standoffs & Side Nailing Strips _ Ci -►)E-1/8" clearance from before unit is slipped into position. See the standoff-wall "Unit Assembly Prior to Installation"section for assembly details. I II C =21-1/2"-min.depth required 2. Frame in the enclosure for the unit with C, =21-3/8"-Ci +Finishing material thickness framing material.The framed opening is 45-1/4" high(46-3/8" - if using base standoffs) x 46-1/2" wide x 21-1/2" deep 1/2" -►( t- ' (1149mm high x 1181 mm wide x 546mm finishing —' material —. . . \ deep). Note: After unit is framed in, steel studs can • C) be used inside of the wood framing to attach the noncombustible material.An optional steel stud framing kit is available for this purpose—see D manual for details.If choosing not to purchase this kit, steel studs can be used in place—to C • /74.5)°! . attach the non combustible material. Use the B optional steel stud kit instructions as a guide. __--c:g A Framing Dimensions A B C D 46-1/2" 45-1/4" 21-1/2" 53-3/4" 1181mm 1149mm 546mm 1365mm *46-3/8" 1178mm *If raised 1-1/8"using base standoffs. 4"(100mm) /ttS> Dia.Inner\ / v'71.8. 7 6-718"(175mm 31" �`'6o Dia.Outer 87mm) 0- °o ;.=-1 sr i 1 42"(1067mm)-0. 6 13 46-1/2"(1181mm) N 72-1/4"(1835mm) 3. For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes.(Do not insulate the fireplace itself.) Regency Excalibur®P90E-11 Direct Vent Gas Stove I 17 installation 4. Note: The unit does not Facing Over 3-3/8" (86mm)Thick have to be completely Top enclosed in a chase.The Header If the facing material is over 3-3/8"(86mm) thick(example:brick or river rock), clearance on top of the 1 install the facing around the perimeter of the face.You may wish to make a unit is 0"tothe standoffs I' i face template as shown on the diagram. so combustible building 10"dia.hole Note:The template should be slightly larger than the actual surround itself to materials can be laid a I through wall accommodate the removal of the surround when having this serviced.The directly on top of the a 19 for Flex surround when fitted must be lifted up and out in order to remove it. m i or for Ri id Pipe standoffs. You must E io g maintain clearance from . I fa a, 11�--"-q the vent to combustible z 1 �;'„ �` Regency provides a template materials for both l g �, �0 on the box. rigid and flex, see the - r/�� 1u, V m Ai ��eo/ NOTE: If using a brick hearth, 004 "Clearances"section. 2" . _ <e �', ' ; ' ---12 the fireplace will need to be �„ �/, � raisedtoaccommodatethebrick �- s a it`r0 thickness.Example:If the brick is Note: 48" (1 19mm) �/ 3-1/2" 4" :�� 2"thick,theunitmustberaised1". is the minimum Opening for gas B �/ connection height for both / �e01pj9t 'p Rigid Pipe ventinflexterminationg 110 F f)c I,00 ,� ,.,r--,e ,, The HeatWave Duct Kit has different Heat Wave clearance and framing requirements,check ,,1.r=--- / the HeatWave manual for details. �='- ,-MThe brick tucks in 1...,,,,,,....„.•••••••„.° below the firebox base. Facing Requirement Hearth Requirements This fireplace requires a non-combustible material extending from the framing header and sides. • ‘ Floor Mounted Fireplaces The flanges on the front face of the fireplace are for a facing thickness ET5 Raised Fireplaces of 3-3/8"(86mm). 41111rr Hearth must be ner 14 48"(1219mm) I - Framing /� thisu flange.d A 1 i A —_ Tile,Marble, Non-Combustible E Non-Combustible °' Brick,or other Material E Material i non-combustible co / One material. '1 E_;., /�. Cement h/B E I- 21-3/4"(552mm) x ,,� �E 4- 1 I rr , �� ♦/ NON � \ � \tN I_35-1l4"(895mm)II (162mm)6-3/8" r4os��J \ Min.3/4"(19mm) Please note that all vertical measurements are taken from the Max.15/16"(24mm) base of the unit excluding risers or bottom stand-offs. C3,+'` 4 a r ♦ ® �k No hearth is required when the unit is raised `/� 3-3/8" :6mm) 3"(76mm)off of ' the floor surface \ • ', / You must take into account � �j.-'+ Poo�Ncs9 the depth of the floor covering (carpet, tile, linoleum, etc.) 25mm) 8 when determining the height \ Fireplace \ Stand of the fireplace stand. 18 I Regency Excalibur®P90E-11 Direct Vent Gas Stove installation Combustible Mantels Because of the extreme heat this fireplace emits,the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagram below. Mantel Clearances Note: A non-combustible mantel maybe installed at 12 10 8 6 4 2 0 a lower height if the framing is made of metal L_11..._�_l.._I_._1_�__1 studs covered with a non-combustible board. The non-combustible mantle when installed 24 12"Mantel at a lower overall height may not be lower d than 6 inches from the top of the fireplace 22 - szt5F46tf,,; ^ opening- 20 ";.Is`'Mantel Mantel can be installed anywhere in shaded area or higher "tit a(es using the above scale. 14 %/ Note: Ensure the paint that is used on the mantel and the facing is"heat resistant"or the paint 12 may discolour. 23" 8 6 — 19" 4 t`.. 2 o • • 27-3/4" / side View to floor Top of Front Opening Mantel Leg Clearance 6-1/2" 165mm 0 MANTEL LEG Non combustible Allowable mantel 7-7/8" (200mm leg projection 10-7/8" 276mm 13-7/8" (352mm) Regency Excalibur®P90E-11 Direct Vent Gas Stove I 19 installation ..�e�mr r,, .r h z e x ixS" -c n AR,, t m H s4 c �Y `m e 'x�soal 'H*tr TrA .°U �, s*=,r '. a# Venting °' � . FPI Direct Vent System (Flex) Horizontal Terminations Only These venting systems,in combination with the P90E-11 Direct Vent Gas Fireplace,have been tested and listed as a direct vent heater system by Warnock Hersey/Intertek.The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the"Exterior Vent Termination Locations"section. FPI Direct Vent(Flex)SystemTermination Kit If a longer run is needed,the FPI Direct Vent Notes: (Part#946-515)Includes all the parts needed system(Flex)kit Is 946-516 which includes 1. Liner sections should be to install the P90E-11 with a maximum run all the parts needed to install the P90E-11 continuous without any joints or seams. of 4 feet. with a maximum 10'run. 2. Only Flex pipe purchased from FPI may 1. 6-7/8"dia.flexible liner(4 ft.length) 1. 6-7/8"dia.flexible liner(10 ft.length) be used for Flex installations. 2. 4"dia.flexible liner(4 ft.length) 2. 4"dia.flexible liner(10 ft.length) 3. spring spacers(4) 3. spring spacers(7) 3. Horizontal vent must be supported every 4. thimble(2) 4. thimble(2) 3 feet. 5. AstroCap termination cap(1) 5. AstroCap termination cap(1) 6. screws(12) 6. screws(12) 7. tube of Mill Pac(1) 7. tube of Mill Pac(1) 8. plated screws(8) 8. plated screws(8) 9. screws #8 x 1-1/2" Drill Point, Stainless 9. screws #8 x 1-1/2" Drill Point, Stainless Steel(4) Steel (4) Vinyl Siding Standoff `= (optional) Wall Thimble • (required in `cike Canada only) AstroCapTM Termination Cap 4" dia. flue pipe 6-7/8" � (175mm) l spring spacer dia. Flue pipe CD �' * ink Regency Excalibur®P90E-11 Direct Vent Gas Stove I 23 installation Exterior Vent Termination Locations - , , r t M '4 A " ,- -G - I A ilill —.- r4„ �'I ��'Ii)L� Fixed Closed INNIInfIIIIIi Pfl11���01100��0� loom 0000868BB89�0001 ►/ I Fixed Closed :slut+_� K Openable�_ M 3 Openable A -- pi Vent Termination Q Air Supply Outlet . Area where terminal is not permitted Minimum Clearance Requirements Canada' USA2 A Clearance above grade,veranda,porch,deck,or balcony 12"(30cm) 12"(3Ocm) B Clearance to window or door that may be opened 12"(30cm) 9"(23cm) C Clearance to permanently closed window D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet(61cm) 18"(46cm) 18"(46cm) from the center line of the terminal(check with the local code) E Clearance to unventilated soffit 15"(38cm) 15"(38cm) F Clearance to outside corner:with AstroCapTermination Cap. 6"(15cm) 6"(15cm) Clearance to outside corner:with all other approved Termination Caps. 14"(36cm) 14"(36cm) G Clearance to inside corner:with AstroCap Termination Cap 6"(15cm) 6"(12cm) Clearance to inside corner:with all other approved Termination Caps. 12"(3Ocm) 12"(30cm) H Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)e J Clearance to service regulator vent outlet 36"(9Ocm) K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(3Ocm) 9"(23cm) L Clearance to a mechanical air supply inlet 72"(1.8m) 36"(90cm)b #3'(91cm)above if within 10'(3m)horizontally. M Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1 m)+ N Clearance under veranda,porch,deck,or balcony 12"(3Ocm)t * 1 In accordance with current CSA B149.1,Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223.1/NFPA 54,National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings $Permitted only if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor • Clearance in accordance with local installation codes and the requirements of the gas supplier a 3 feet(91cm)within a height of 15 feet(4.5m)above the meter/regulator assembly b 3 feet(91cm)above -if within 10 feet(3m)horizontally 24 I Regency Excalibur®P90E-11 Direct Vent Gas Stove