23A-053 (4) 12 WEST CENTER ST BP-2021-1516 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 23A-053 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category. SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1516 Project# JS-2021-002525 Est.Cost: $22000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: TRINITY SOLAR 098295 Lot Size(sq. ft.): 5052.96 Owner: GIORDANO LESLIE A Zoning:URB(100)/ Applicant: TRINITY SOLAR AT: 12 WEST CENTER ST Applicant Address: Phone: Insurance: 4 OPEN SQUARE WAY, SUITE 410 ATTN: APPLICATIONS D (413) 203-9088 0 WC HOLYOKEMA01040 ISSUED ON:6/21/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 17 PANEL 5.78 KW SOLAR SYSTEM ON ROOF POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. ' Certificate of Occupancy Signature: � , � • , • , ! / FeeTvpe: Date Paid: Amount: Building 6/21/2021 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner ? I IIn.P 5 Department use only c. c n City of Northampton Status of Permit: '� IT o Q Building Department Curb Cut/Driveway Permit x- 212 Main Street Sewer/Septic Availability 1L-i N ^^ F'F. Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans - ) .phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans �L • Other Specify CT) (_APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Map 23/1 Lot v` Unit 12 West Center St, Northampton, MA 01062 Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Leslie Giordano 12 West Center St,Northampton,MA 01062 Name(Print) Current Mailing Address: 413-250-8935 Please see attached Telephone Signature 2.2 Authorized Agent: Michael A White �' /� 4 Open Square Way-Suite 410,Holyoke,MA 01040 Name(Print) Current Mailing Address: 114" A, v !i t 413-203-9088 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 6000 (a)Building Permit Fee 2. Electrical 16000 (b)Estimated Total Cost of Construction from(6) 3. Plumbing Building Permit Fee , DG 4. Mechanical(HVAC) ?5'- 5. Fire Protection 6. Total =(1 +2+3+4+5) 22000 Check Number 4*27 IS This Section For Official Use Only Building Permit Number: g)'2021- 15/(o Date Issued: Signature: / - 2,' 202( Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage cYo (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO Q DONT KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW Q YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO 0 IF YES, describe size, type and location D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO O IF YES, describe size, type and location: '' F E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO 0 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing ❑ Or Doors E Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [I] Siding [0] Other[0] Solar Installation Brief Description of Proposed Work: install 5.'8 kW DC solar on roof(17 panels).Will not exceed building footprint,but will add 6"to roof height. Alteration of existing bedroom Yes X No Adding new bedroom Yes X No Attached Narrative Renovating unfinished basement Yes x No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves_ Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Please see attached ,as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date Trinity Solar , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Michael A Whitejjj Print Name ( t+/ X _, v Acrl Signature of Own er/A g9ent Date 6/17/2021 SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder Michael A White CS-098295 License Number 5 Voyer Av , East Longmeadow, MA 01028 9/29/2021 Address ! # f Expiration Date II413-203-9088 Signature } Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Trinity Heating&Air Inc. DBA Trinity Solar 170355 Company Name Registration Number 20 Patterson Brool ad- t;J0,West Wareham,MA 02576 10/11/2021 Address /I 1 I f i Expiration Date h / r' r i 41 -20 - Telephone 3 3 9088 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes p No ❑ 11. — Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature • ® NJ,Electrical Contractor business permit number 34EB01547400 NJ,HIC reg.#13VH01244300 SOLAR For other jurisdictions,please visit:http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM 1, Leslie Giordano (print name) am the owner of the property located at address: 12 W Center St Florence Northampton MA (print address) I hereby authorize Trinity Heating & Air, Inc. DBA Trinity Solar and its employees, agents, and subcontractors, including without limitation, , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my property,applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local solar incentive program. This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al. to populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise, amend and modify application, submission and certification documents ("Approvals Paperwork"), including those for which signature pages are included herewith for my signature, in furtherance of the related solar transaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of Approvals Paperwork when submitted.My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that these authorizations are not required to proceed with the solar transaction and are not a condition of the related solar agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. Electric Utility Company: National Grid Electric Utility Account No.: 53306-35003 N me on Electric Utility Account: David Hardy n n Customer Signature Leslie Giordano David Hardy Print Name 4/30/21 April 30, 2021 Date Corporate Headquarters 1-877-SUN-SAVES 2211 Allenwood Road Ph: 732-780-3779 Wall, New Jersey 07719 Fax: 732-780-6671 www.trinity-solar.com FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS' REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. WESTSHORE WrAimE DESIGN ENGINEEIRS, P.C. 10D GREA? OAKS BLVD, I SLATE 115 k_bANI ! NET YO'riK I 1220 To: Trinity Solar 4 Open Square Way#410 Holyoke,MA 01040 Date: June 4,2021 Ref.: 21060056 Subject: Giordano Residence 12 West Center Street Northampton, MA Dear Trinity Solar, The following references the Giordano Residence in Northampton, MA: 1. Existing roof framing: Roof 2: Conventional framing is 2x12 at 24"o.c. with a 14'-0" max span (horizontal rafter projection). Roof 4&5: Conventional framing is 2x4 at 24"o.c.with a 10'-0"max span(horizontal rafter projection). The roof 2 existing structure is capable to support all the loads that are indicated below for this photovoltaic project.Roofs 4&5 are capable after installing new collar ties between rafters without existing collar ties at 1/3 of the rafter length from the ridge or sistering a new 2x6 to each existing 2x4 rafter below the solar array. 2. Roof Loading: - 4.33psf dead load(modules plus mounting hardware) - 40psf ground snow load - 5.1psf roof materials (1.1psf 2x4, 1.5psf sheathing, 2.5psf asphalt shingles) - Exposure Category B, 140mph wind(3 sec.) This installation design will be in general conformance to the manufacturer's specifications,and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 64"o.c. span between mounting brackets and secured using 5/16" diameter corrosive resistant steel lag bolts. To evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter& min. 3"penetration of lag bolt per bracket, which is adequate to resist all 125mph wind live loads including wind shear. Per NDS Section 11.1.4 clearance holes equal to the diameter of the shank need to be bored into primary a primary framing member for the full length to the threaded portion of the screw to avoid splitting of the framing member. POiOFMAss Thank you. ��� EYP.630-22 '1,(' NICOLASI A. Westshore Design Engineers N Irrl CIVIL NO. 50222 RFGIS i EO c, '"SS/ONALEw� v 6/4/2021 John Eibert Nicolas Nitti, PE Project Coordinator President WestShore Design Engineers 1100 Great Oaks Blvd. I Suite 115 I Albany,NY 12203 1518.313.7153 INSTALLATION OF NEW r1 EST CFNT('R STRFFT• — ROOF MOUNTED PV SOLAR SYSTEM • 12 WEST CENTER STREET NORTHAMPTON, MA 01062 • Issued/Revisions • VICINITY MAP I SITE NO. O DESCRIPTIONnn DATE SCALE:NTS Project Title: GIORDANO,LESLIE- TRINITY ACCT B:2021-04-578334 Project Address: 12 WEST CENTER STREET NORTHAMPTON,MA 0106) 42.332934,-72.672854 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX PV-1 COVER SHEET W/SITE INFO&NOTES Drawing Title: 1.THE INSTALLATION CONTRACTOR IS B a. THE VOLTAGE FROM THE PANELS IS 14. BICURRENT PREVAILING UTILITY 1B JUNCTION BOX RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECFICATIONS,STANDARDS, KCMR TNWSAND CIRCULAR MILS ARO FOLLOWING ALL INSTRUCTIONS CONTAINED IN THEONS AND DRAVA. INVERTERRE AND THE DURING DAYLIGHT HOURS.INALS RUTNE AND 15 THIS SET OFLNSH E BEEN PREPARED LW KILO.REMENTS kVA W Ti ARE PV-2 ROOFi PLANl 3UG/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND MVH KILO-WATT HOUR ELECI.RII.AL LINE DIAGRAM TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL ONCE L LINE PV-3 RICAL THE INSTALLATION CONTRACTOR IS THAT THE SOLAR MODULES ARE ENERGIZED APPROVED.THE INSTALLATION MCB MAIN CRCUIT BREAKER RESPONSIBLE FOR INSTALLING ALL EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONTRACTOR IS RESPONSIBLE FOR MOP MAIN DISTRIBUTION PANEL AP APPENDIX Drawing Information AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR INSTAWNG ALL SYSTEM COMPONENTS AS MLO MAIN LUG ONLY maw..DATE: 6/2/2021 INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM SHALL BE MARKED DESCRIBED IN THE DRAWING PACKAGE. AHD MOUNTED OMWN BY: MD MANUAL. CLEARLY IN ACCORDANCE WITH THE 16 ALL INFORMATION SHOWN MUST BE NTG MOUNTING 3.THE INSTALLATION CONTRACTOR IS NATIONAL ELECTRICAL CODE ARTICLE 6908 CERTIFIED PRIOR TO USE FOR N NEUTRAL REVISED BY: RESPONSIBLE FOR READING AND 70S CONSTRUCTION ACTIVITIES. NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS,COMPONENT 10. PRIOR TO THE INSTALLATION OF THIS NW NOT IN CONTRACT AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NOR NUMBER System Information: INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND A NTS NOT TO SCALE OC SYSTEM SIZE: 5.78LW CONTRACTOR IS ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW ABBREVIATIONS OCF OVER CURRENT PROTECTION AC SYSTEM SITE SAW COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, P POLE AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. AMP AMPERE AB PULL BOX TOTAL MODULE COUNT: 17 INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO THE SYSTEM START UP THE AC ALTERNATING CURRENT PH0 PHASE MOW In USED: IIMwHA 340 COMPONENTS. INSTALLATION CONTRACTOR SHALL ASSIST IN AL ALUMINUM PVC POLYVINYL CHLORIDE CONDUIT MODULE SPEC 4: QPTAR DUO BIC CE ;::' 4.ONCE THE PHOTOVOLTAIC MODULES ME PERFORMING ALL INITIAL HARDWARE AF AMP.FRAME PWR POWER MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTIVITY AFF ABOVE FINISHED FLOOR OTT QUANTITY UTILITY COMPANY: NATIGRIO SHOULD HAVE A MINIMUM OF ONE CHECKS. MG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY ACCT 4: S3306.35003 ELECTRICIAN WHO HAS ATTENDED A SOLAR 12. FOR THE PROPER MAINTENANCE AND AWG AMERICAN WIRE GAUGE 5N SOLID NEUTRAL UTILITY METER B: 4169406B PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE C CONDUIT(GENERIC TERM OF ISWBD SWITCHBOARD DULTYPF: SUNNWA S.FOR SAFETY,IT IS RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION RACEWAY,PROVIDE AS SPECIFIED) TIP TYPICAL INSTALLATION CREW ALWAYS HAVE A MANUAL COMBINER BOX U.O.I. UNLESS OTHERWISE INDICATED MINIMUM O TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CB CIRCUIT WP WEATHERPROOF TOGETHER AND THAT EACH OF THE TELEPHONE UTILITIES ARE SUBTECT TO FINAL CRT XFMR TRANSFORMER INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE APPROPRIATE VERITY n CURRENT TRANSFORMER ..72 MOUNT 72 INCHES TO BOTTOM OF Rev.No. Sheet FIRST AID AND CPR. COMPANIES AND OWNERS. CU COPPER ABOVE FINISHED FLOOR OR GRADE DIRECT CURRENT P 1 P V 6.THIS SOAR PHOTOVOLTAIC SYSTEM IS TO BE 14. ALL MATERIALS,WORKMANSHIP AND DC DISCONNECT SWITCH - INSTATHE NATIONAL ELECTRICAL THE CONVENTIONS NT OF CONSTIMPROVEMENNTS FOR WTHN SIEE DISCWEECTRIC THE SUPICAIDE TILELOCALHEREIN SHALLINSTALLERMAY NEC SHALL IN ACCORDANCE WITH: BE ELECTRICAL METALLIC TUBING GOVERN. AND/ORCT PREVAILING MUNICIPAL EMT FUSIBLE SWITCH 7.ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, FS FUSE WITHTHIS SYSTEM ARE TO BE LISTED.ALL STANDARDS AND REQUIREMENTS FU GROUND EQUIPMENT - EQUIPMENT WILL BE NEMA 3R OUTDOOR DIED GROUND FAULT INTERRUPTER ,...r. RATEDUNIESS INDOORS. NI FREQUENCY(CYCLES PER SECOND) Tr I n i tya GENERAL NOTES SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY O EQUIPMENT. 2211 Allenwood Road 877-786-7263 Wall,New Jersey 07719 www TnMY-SoIIE.Eu, • NOTES'.•REFEP TO MODULE SPECS FOR MODULE DIMENSIONS •DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE UNIRAC CLAMP NEW PV SOLAR MODULE,TYPICAL TinaTO SPEC MEET Ma OETMR (REFER TO EQUIPMENT SCHEDULE ECM SPECS AND QUANTITIES) III 1111 SOUR MODULE SOLAR MODULE A. NEW MOUNTING FOOT/ATTACHMENT .• POINTS,TYPICAL IMFfPTO UNIRAC'V FOOT UNIRAC RAIL \ S ?a� ENGINEERING LETTER FOR SPACING AND tr.g LINER TOSPec BIM Fa WA. I IN TO SPEC VAST Fa DETAR EMS) NEW UNIMC MIL,TYKAI '* TO BE MOUNTED PERN UM NDIC TO UNIRAC FLASHING EXISTING ASPHALT SHINGLES - -- STRUCTURFIRFFERTOUN•AC imp,.TOsecVmFa LOpR3I� MM IO ERALEN WI IRA FaISL2CV SPECIFICATION/DATA SHEET FOR �_J DEEMS TYPICAL NEW END CIA, S.S.LAG BOLT APOC SEALANT N \ '�F ti p (WERT.,UNIRAC SPECIFICATION/ DOMED ENSINEEM LETTER FOR SFtt31 SOLAR MODULES SHALL NOT , .. DATA SHEET LOP°M AKS) EXISTING RAFTER EXCEED PEAK HEIGHT. • NEW MD(11P,TYPICAL BERKE°DWINFFRSLETDR FOR VMS — (REFER TO UNAAC SPECIFICATION/ ■QATTACHMENT&CUP DETAIL DATA SHEET FOR ROARS) PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF YSUIE:NOT TO SALE ❑FGLF:NOT TO X. ❑SUIE.NOr to SALE ARRAY SCHEDULE • I. I __...._ Issued/Revisions HMI .. I n nuammwv0..P.NN.r m NO. DESCRIPTION DATE R3 H� (CONDUIT TO BE TRENCHED APPROX.40 FEET) Project Title: GIORDANO,LESLIE- --„,--— TRINITY ACCT R:2021-04-578339 — GARAGEProject Address: 12 WEST CENTER STREET NORTHAMPTON,MA 01062 42.332934;72.672854 BACK Ac Drawing Title: ® R2 nl PROPOSED PV SOLAR SYSTEM J J ® ^o0 J,d Drawing Information N U DRAWING DATE: W2/2021 I—_I DRAWN BY: MD U I:' REVISED BY: W Z ZQ - u J System Information: 'UlR DWELLING ■ oy DC SYSTEM SIVC SAW m: AC SYSTEM SIZE: SNW PITCH:32' ORIENTATION:1' >NGig TOTAL MOgAE COUNT: 17 ROOT2 MODULE R1 d U MODULE HAMVFM 340 CH:LE U MOLE SPEC itGK.DUO BLKGE,MO ORIENTATION.al Q UTILITY COMPANY: NAP%GRID PROF 3 DEAL Y PE, F: S33OF35W3 ODULES T NOTES: UTILITY METER P. 41690068 PITCH:23' ��PP��I�I�II))) ORIENTATION:3S9' DEAL TYPE: $DNNOVA I.)ALL THE SHALL BE INSTALLED IN ACCORDANCE ROOF A WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. lA MODULES:i 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. h PNCN.23 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE HELD VERIFICATION. I H Rev,No. Sheet ORIFMTATON l7! 0.)AN AC DISCONNECT SHAH BE GROUPED WITH INVERTERIS HNEC 690.13(E). EP ROOF 5 STALL OUTDOOR EQUIPMENT SHALL BE MIN TIGHT WITH MINIMUM NERM 3R RATING. MOOUTATIO FRONT P1 PV AL:23 6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. ORIEMTAl10N:A ROOF SYMBOL LEGEND 'uIMBING SCHEDULE EQUIPMENT SCHEDULE PODULE5:0 ATE I SPICE ITCH:23' INDICATES ROOF RESIGNATION.REFER TO INDICATES NEW UNFUSD PV DISCONNFRTO Bf NDIUTES NFW PV ONLY SUBPANEI ORIENTATION:269' ® ARRAY SCHEDULE FOR MORE INFORMATION U� INSTALLED WISIDE IUTILTTT ACCESSINEI © TO BE INSTATED 17 HANWHA 340(UPEAK DUO BLX-GVE 340) ROOF] MODULES: INDICATES NEW PV SOLAR MODULE RED MODULES 1 SESOOOH-US0008NC4 ONEN 35' a • • OMENTATINl:181' H INDICATES EXISTING METER LOCATION INDICATE PANELS HEDULE USE MICRO PECSYEOFRS.REFER IOC INDICATES NEW adxpIMER 0 TOFWIPMFNL SCHEDULE FOR SPECS. �' � '�" ROOF 8 MODULES:O OTHER OBSTRUCTIONS Y PITCH:28' ® INDICATES E INSIDE OUTSIDE. ELECTRICAL PANEL LOCATION: n ROTATES NEW PRODUCTION METER TO NE INSTALLED SD ORIENTATION:91' ...CATES EXISTING SERVICE DISCONNECT SOLAR ROOF 9 MODUIF5:0 PITCH:]1' INDICATES NEW BREAKER ENCLOSURE TO BE INDICATES NEW REVERTER TO BE ORIENTATION:LID. INSTALLED OUTSIDE El NDIGTES EXISTING TRANSFER SWITCH 2211Aknw000 Road O77867283 INSTALLED OVTSIOF IUDLITY ACCESSIBLFI REFER TO EQUIPMENT SCHEDULE FOR SPECS WRH.New Jersey 07719 vow*Trony-Solar.can SOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS C Engineer/license Holder 17-340W MODULES W/1 SOLAR EDGE P340 PER MODULE 15 ADC MAX PER STRING ARRAY CIRCUIT WIRING NOTES [TOTAL) I.)LICENSED ELECI RICIAN ASSUMES ALL RESPONSIBILITY 1 STRING OF 9 MODULES IN SERIES-360 Vmaa FOR DETERMINING ONSITE CONDITIONS AND 1 STRING OF 8 MODULES IN SERIES-380 Vms. EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020 '2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 8"a8" O c _.__.. _ ._... 2.I LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON JUNCTION ......... .._ ...__.___. __.____._.. 'DWELLING( INS i ASHRAE MINIMUM MEAN EXTREME DRY BULB BOX ' TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO ISTOIBE E 6INATED IN INSERIES-NSIVmaa '1 STRING TO BE TERMINATED N PARALLEL INSIDE INVERTER 1 INSTALLATION LOCATION.LOWEST EXPECTED AMBIENT I I-. I • TEMP=-16T I • (GAR 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 1 STRING OF 9 MODULES INI SERIES-380Vmaa .. ............ 8'a6 ��-7� ., ON ASHRAE HIGHEST MONTH 2%DRY BULB --' JUBCOTION C 1C-1•.........__...__.....__...._....__...........................I I l �y JUNCTION TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO •1 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMP 33'C DC DISCONNECT ( 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I TEMPERATURES DO NOT EXCEED 47.0 IN THE UNITED F STATES(PALM SPRINGS,CA IS 44.IT).FOR LESS THAN9 ' CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5'ABOVE ROOF AND USING • Issued/Revisions THE OUTDOOR DESIGN TEMPERATURE OF'Mc OR LESS • TALL OF UNITED STATES) • 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I ' CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH m�TONwawra w+' ...>>... NEC RHO.12(A)THROUGH(01 NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED ll TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 IAI(4I DUSTING 240V 10 HOER: GIORDANO,LESLIE- ].1 UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BF 10120/24V 200A MAIN BREAKER INTERNAL REVENUE GRADE MONITORING IDENTIFIED WITH THE FOLLOWING OUTER FINISH: UTILITY METER CONTAINED WITHIN SOLAR EDGE INVERTER POSITIVE CONDUCTORS=RED 200A BUSBAR SOLAR EDGE ION.ROUND-30-240MB TRINITY PCR A:2021-04-5]8339 NEGATIVE CONDUCTORS=BLACK NEC xlos(q(x) _ i Project Address: e.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE 410 PV p'S� WIRE TYPE ROW/OR EQUIVELANT AND SHALL BE " • • 12 WEST CENTER STREET PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT - NORTHAMPTON,MA 03062 SUNLIGHT.SUB ARMY CO ERNDUIT LONG THAN 24'SHALL SMART METER CONTAIN s 20 CURRENT CARTING CON DOCTORS AND 100A BREAKER ENCLOSURE pO N 60A UNCAUSED �� 42.332934,-72.672854 WHERE EXPOSED TO DIRECT SUNLIGHT SHALL W/2p30A BREAKER METER DISCONNECT CONTAIN s 9 CURRENT CARRYING CONDUCTORS. - wnnumr INVERTER NI z4Dv i0 )BB44001 z4o!�v ,w 10 p Drawing Title: 9.1 ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLE55 µy'anmu.l D •O l000enol _�,r0� JiP • OTHERWISE NOTED ..-� ..^ r Y --- 0 IO.IFIE%ISLE CONDUIT SHALL NOT BE INSTALLED ON �4"'" �f 0 PROPOSED PV SOLAR SYSTEM ROOFTOP AND SNAIL BE LIMITED TO 12'IF USED E�'���.j 1~„1 , f �Tit ' ,- CONNECTED • 1. B B TOTH �)TO THE SUPPLY SIDE OF A SERVICE SHALL BE l - LIP J J : I DRAWING DATE: 6R/2021 LOCATED WITHIN LOOT THE POINT OF CONNECTION NEC I EXISTING MAIN BREAKER LOAD SQUARED SQUARED ..._......_..1 DRAWN BY: MO 690.9(4I0)(2) I CENTER PPS:Q021OOBNF DU222RB REVISED BY: 2p30N RACKFEED BREAKER W/3BR BREAKER IC 12.1WMIME ANE DTHE OTHER SOURCES INVEED ERTER, PRAR ONE A "' NEC MS.lx(B) BREAKER MIME AND THE OTHER AN INVERTER,PS BACXFEEO BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY System Information: NEC 705.1201N3N2) OC SYSTEM SIZE: STREW I3.)AU SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY AC SYSTEM SIZE: SkW GENERATION CIRCUITS AND NO UNUSED POSITIONS OR TOTAL MODULE COUNT: 17 LOADS MODULES USED: MNWHA 340 144 ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE MODULE SPEC a: OPEAY DUO BUG61.MO A NFMA 3R PAYING UTILITY COMPANY: NAPE GRIT. UTILITY ACCT.: 53306.35003 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER._ 4169406/ REQUIRED CONDUCTOR AMPACI TY PER-T RING [NEC 690.801)(IU:(15.00•1/5)1=18.75A • DEAL TYPE: S unxOVA PV MODULE SPECIFICATIONS AWG P10,DERATED AMPACITY HANWHA 340(OREAK DUO BLK-GA(•340) Rev.No. Sheet AMBIENT TEMP:MY.TEMP BERATING FACTOR:.TV RACEWAY DERATING=4 CCC:0.60 Imp 10.2 (40•.9610.80.30.72A Amp 33.94 NOTE:TXINUUIT TTAT S:+AI:N.cons RN TNT NSYVcOTEP:CONTRACTOR !O MEET OA OT1,0 NEC:ADM,,..1;D RIIXii;YSN6 P1 PV -j 30.]U'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 40.66 I46 10.52 A 16 THWN-2 GEC TO EXISTING GROUND ROO G 1'PVC W/4410 TOWN-2,1410THWr42 GROUND IIRENCHED APPROX.40') TOTAL AC REQUIRED CONDUCTOR AMPACITY 21.00A'225=26.25A B 3/4"CONDUIT W/2-NIO THWN-2,1-410 TIIVVN-2,1410TNWN.2 GROUND AWG N30.DERATEDAMPACITY INVERTER NI-SESDDOH USOWBNC4 C 3/4"CONDUIT W/4-N10 THWN-2,1-N10THWN-2 GROUND >. AMBIENT TEMP:30Y,TEMP DEMTTNG:1.0 O RACEWAY 0RATI/IG_3CCC:N/AC Tr n i ty 40A•1.0-40A Imp 13.5 Pout $NeD D 3/4'CONDUIT W/4-NlO THWN WN- -Z,INI01112 GROUND 40A'26.25A,THEREFORE AC WIRE SIZE IS VALID limp 380 Im4k 21 E 3/4"CONDUIT WI 2410 THWN-2.1410 WV/N-2,1410THWN-2 GROUND Roc PC/m 26.2 CALCULATION FOR PV OVERCURRENT PROTECTION - - 340 «orn ID 2406 F N10 PV WRE(FREE AIR)W/BG BARE COPPER BOND TO ARMY SOLAR TISTAL INVERTER CURRENT:21.00A 21.0OA'i.25=26.25A 2211 Allenwood Road 077.786-]283 •-C 30A OVERCURRENT PROTECTION IS VALID wall,New Jersey 07719 www.TTHRE-Solarcorn AC�® DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 5/20/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Mark Grasela Arthur J.Gallagher Risk Management Services, Inc. PHONE FAX No).856 482-1888 4000 Midlantic Drive Suite 200 (A/C,No.Ext):856-82-9900 Mount Laurel NJ 08054 ADDRESS: CherryHill.BSD.CertM@AJG.com INSURER(S)AFFORDING COVERAGE NAIC#_ INSURER A:Gotham Insurance Company 25569 INSURED TRINHEA-03 INSURER B:National Union Fire Insurance Company of Pittsburg 19445 Trinity Solar Inc. 4 Open Square Way, Suite 410 INSURER C:Endurance American Specialty Ins Co 41718 Holyoke, MA 01040 INSURERD:Liberty International Underwriters INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:206332321 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DDIYYYY) (MMIDD/YYYY) LIMITS A X I COMMERCIAL GENERAL LIABILITY GL202100013378 6/1/2021 6/1/2022 EACH OCCURRENCE $2,000,000 J CLAIMS-MADE X OCCUR DAMAGE TO RENTED PREMISES(Ea occurrence) $100,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY X JEC LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ B AUTOMOBILE LIABLITY CA 2960145 6/1/2021 6/1/2022 ' COMBINED SINGLE LIMIT 6/1/2022 2,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY _ AUTOS ONLY (Per accident) $ A UMBRELLA Ufa X OCCUR EX202100001871 6/1/2021 6/1/2022 EACH OCCURRENCE $5,000,000 C X EXCESSLU1e ELD30006989100 6/1/2021 6/1/2022D - CLAIMS-MADE 1000231834-05 6/1/2021 6/1/2022 AGGREGATE $5,000,000 DED RETENTION$ Limit x of$5,000,000 $19,000,000 B WORKERS COMPENSATION WC 13588107 6/1/2021 6/1/2022 PERTUTE ERH AND EMPLOYERS'LIABILITY Y/N ANYPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBEREXCLUDED? n N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 B Automobile CA 2960146 6/1/2021 6/1/2022 All Other Units $250/500 Comp/Collusion Ded. Truck-Tractors and Semi-Trailers $250/500 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS, Evidence of Insurance AUTHORIZED REPRESENTATIVE I OZ'i f ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts ` Department of Industrial Accidents 1 Congress Street,Suite 100 Boston, MA 02114-2017 A;-,:a...sic www,mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leaihly Name (Business/Orgarizationflndividual): '1-I'inif V 1'1eatiii,& Air Inc. DB A Trinity Solar Address: 2211 Allensyood Rd City/State/Zip: Holyoke,MA 01040 Phone#: (413)203-9088 Are you as employer?Cheek the appropriate box; Type of project(required): 1 1.0I no a employer with 1 6 employees(full and/or Ian-tuner.' 7, Q New construction 2.0 tam a sole proprietor or pannership and have no employees working fur me in 8 0 Remodeling any capacity [No workers'comp.insurance required.] 3.Q I am a homeowner doing an ttiwrk myself No workers'comp insurance mitered] t 9. ❑Demolition 4.0 t am a homeowner and wilt be hiring contractors to conduct all work on my property. I will 10 0 Building addition moon that all comment*either have workers'compensation insurance or arc sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 51/�am a general contractor and I have hired the sub•contractorx listed on the attached sheet. l 3_©Roof repair These sub-contractors have employees and have workers'comp insurance z 14.0Other Solar Installation or]we arc a corporation and its officers have exercised their right of cxernption per Min c. 152.a t(a),and we have no employees.[No workers'comp insurance required.] 'Any applicant that checks hoz al trust else,fill out the section below showing their workers'compensation policy information. 'Homeowners who submit this affidavit indicating they arc doing all work and then hire outside comment*must submit a new affidavit indicating such. tContracrcrs That check this hoe must attached an additional sheet showing the name of the sub'cnntractors and state whether or not those entities have employer-, If the aub.ctmtractors have employees,they trust provide then workers'comp policy number I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and joh site information. Insurance Company Name: National Union Fire Insurance Company of Pittsburg Policy#or Self-ins.Lic.#: WC 13588107 Expiration Date: 6/1/2022 Job Site Address: 4 Open Square Way, Suite 410 city/state/zip: Holyoke MA, Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MOL c. 152,*25A is a criminal violation punishable by a%1s24u9 to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verihc ion. I do hereby cert fy is der the pains td pen res o r' ry that the inform ' -provided above is true and correct Signatures l✓ _ Daze: I 'f 2.c.''C Phone#: 7 - 7 i0- 3" V Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: i Commonwealth of Massachusetts �= Division of Professional Licensure Board of Building Regulations and Standards CQnstl°uetiun' uparvisor CS-098295 Expires:09/29/2021 MICHAEL A WHITE 48 MOORE STREET EAST LONGMEADOW MA 01028 Commissioner f; EVe,viauk, Office of Consumer Affairs and Business Regulation 1000 Washington Street- Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card Registration: 170355 TRINITY SOLAR INC. Expiration: 10/11/2021 D/B/A TRINITY SOLAR 2211 ALLENWOOD RD WALL,NJ 07719 Update Address and Return Card. SGA 1 O 20M-05,17 Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:SuooIement Card before the expiration date. H found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 170355 10/11/2021 1000 Washington Street -S 'e 710 TRINITY SOLAR INC. Boston,MA 02118 D/B/A TRINITY SOLAR NEIL GREENE � 20 PATTERSON BR OOK ROAD UNIT 10 ,�(� ,yG(0•4 WEST WAREHAM,MA 02576 Not valid without signature Undersecretary Single Phase Inverter Z with i HD -Wave Technology for North America TI SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / min SE7600H-US / SE10000H-US / SE11400H-US 12-25 �' m YEAR roiar'� y 2. WARRANTY. 7C1 n4 s : I* • @ • • 0 0 0 4110 ‘IF IF III Optimized installation with HD-Wave technology Specifically designed to work with 5 Extremely small power optimizers Record-breaking efficiency / Built-in module-level monitoring I Fixed voltage inverter for longer strings I Outdoor and indoor installation I Integrated arc fault protection and rapid shutdown for I Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) I UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar - I Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT 3800 @ 240V 6000 40 240Vi1 00( r J 240 Rated AC Power Output 000 7600 1 • 3300 8)2085' 5000 @208•? � 1000u"@ 208• VA 3800 @ 240V 6000 @ 240V 1140E @ 240V Maxirnurn AC Power Output 3000 5000 7600 • i0000 VA 3300 @ 208'V' 5000 @ 208V 1000E @ 208V AC Outpu�Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ I ✓ • ✓ Vag (211-240-264) AC Outp.;t voltage Min.-Ncm.-Max. ✓ ✓ ✓ Vac - - (183-208-229) AC Frequency(Nominal) j 59.3-60 60 5" Hz Maximum Continuous Output 2 5 tb L1 25 32 42 i 47.5 A Current:a240V Maximum Continuous Output I Current©208V 16 24 48.5 A . 1 GFDI Threshold 1 i A • Utility Monitoring,Islanding Protection Country Configurable 1 Yes 'ruesl'i.olds INPUT Maximum DC Power @240V 4650 5900 9300 11800 15500 1650 Maximurn DC Power @208V 5100 7750 5500 W Transformer-less, • Ungrounded • Yes • Maximum input Voltage 480 I Vdc Nominal DC Input-Voltage 380 400 Vdc Maximum Input Current @240VtP' 8.5 i 10.5 i .5 16.5 20 27 1 30.5 i Adc Maxi:r.un-i Input Current @208V x' 9 13.5 - 27 i Adc Max.Input Short Circuit Current 45 I Ads Reverse-?olarity Protection 1 Yes Ground-Fault Isolation Detection 600kra Sensitivity Maximum Inverter Efficiency 99 . 99.2 I % CEC Weighted Efficiency 99 99 @ 240V • 98.5@208V lhrt�.T�: ,..e,r , ,h.i ,-, <2.5 i W ADDITIONAL FEATURES Supported Communication Interfaces l r_-85,Ethernet.ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optiooar j • Rapid Shutdown-NEC 2014 and A;itcmatic Rapid Shut-town upon AC Grid Disconnect • 201769(Tr 12 • STANDARD COMPLIANCE Safety U. UI.1741 )A:UL16998,CSA C22.2,Canadian AcCI according to T.I.L M-(?- Grid Conn _tor,Standards 1 I_EE1547,Rule 21,Rule 14(Hi) =mi-si;n FCC Part 15 Class 3 INSTALLATION SPECIFICATIONS itp.,t r;S r G 3;4"minimum;14-6 AWG 3/4.minimum/144 AWG Range DC input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 1 3/4"minimum/1-3 strings/14-6 AWG AWL Rance Dimensions with Safety Switch in/ (HxWxD) 17.7x14.6x6.8 450x370x174 213x14.6x7.3;540x370x185 I mm Weight with Safety Switch 22/10 1 25.1!11.4 1 26.2/11.9 38.8/17.6 1 ib/ko kg i Noise I <25 <50 i l eBA Cooling I Natural Convection Operating Temperature Range i -40 to,140/--25 to+60"'(-40"F/-40"C option)' I"F I'C Protection Rating I 1 NEMA 4X(Inverter with Safety Switch) • or other regional settings please contact SolarEdge support r<,A higher current source may be used;the inverter will limit its input current to the values stated s;,Revenue grade inverter P/N:SExxxxH-US000NNe,2 fill ror power cie-rating information refer to.https://www.so anedge.con;sitesldefauhrfileVse-tempera urx-Berating-note•na.pdf "'-40 version P/N:SExxxxH-U5080NNJ4 V SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the Soartdge boo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technobgies,Inc.All Rol-IS other trademarks mentioned herein are trademarks of their respective owners.Date 122018,N01/ENG NAM.Subject tc change without notice. 3 I ilt d by , �3 i 31 Q.ANTUM /DUO/ t \ \ •t, \ \ * } ,, 9 9 t 31 ‘,, \, 1\‘..,..,, ,,,iti.\ t \',1/4 . P,,. ,.A'K 'L. \ U ‘‘., ,,\ — \\ a\ ,, QUANTUM SOLAR MODULE The new Q.PEAK QUO-G5 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUMEs world-record-holdingcell —�-- concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding p erformance under --" . real conditions - both with low-intensity solar radiation as well as on _> f hot, clear summer days. ,: 0Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY -' Higher yield per surface area, lower BOS costs, higher power -: __classes, and an efficiency rate of up to 19.9%.410,41 INNOVATIVE ALL-WEATHER TECHNOLOGY ,.j ,10 Optimal yields, whatever the weather with excellent low-light { and temperature behavior. �„ ENDURING HIGH PERFOF,:t =; Id i Long-term yield security with Anti LID and Anti PID Technology', urnRESEARCH CELLS Hot-Spot Protect and Traceable Quality Tra.QTM. ;-TOP BRAND EV �rzExw�� 1, MODULES '�;' eunaet xm' sear PROTEai Ai EXTREME WEATHER Rya,"it,s ,,= 2017 ,% ���u' High-tech aluminum alloy frame, certified for high snow ""`a ' ANTI LIT TECHMOlaaY (5400Pa)and wind loads(4000Pa)regarding IEC. A"" .____, A RELIABLE INVESTMENT VDE itt#Th to, Inclusive 12-year product warranty and 25-year Quality Tested linear performance guarantee 2. *sm =u , . mom. x; STATE OF THE ART MODULE TECHNOLOGY 1D.40032587 N`- ....""—? Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. r APT test conditions according to IEC/TS 62804-1:2015, method 8(-1500V,168h) 2 See data sheet on rear for further THE IDEAL SOLUTION FOR: information. Rooftop arrays on Rooftop arrays on residential buildings1:31 comma-cal/industrial buildings buildings Engineered in Germany Q CELLS MECHANICAL SPECIFICATION Format 66.3in x 39.4in x 1.26in('ncluding frame) (1685mm x 1000 MITI x 32mm) Weight 41.2 lbs(18.7 kg) - N. Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with ant-reflection technology . Back Cover Composite film Frame Black anodized alum numel Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells Junction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83 n '� (70-85mm x 50-70mm x 13-21 mm),decentralized,IP67 Cable 4mm=Solar cable;( )a43.3 in(1100mm),(-)?.43.3 in(1100mm) - ' 1 ...... ' Connector Multi-Cortact MC4,IP65 and IP68 =<° __1 "" ELECTRICAL CHARACTERISTICS POWER CLASS 305 310 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE 4t5 W/-O W) Power at MPP2 P, , [W] 305 310 315 320 325 330 Short Circuit Current. he [A] 9.93 9.98 10.04 10.09 10.14 10.20 Open Circuit Voltage* V. IV] 39.35 39.61 39.87 40.13 40.40 40.66 Current at MPP*i. IMP, [A] 9.44 9.50 9.55 9.60 9.66 9.71 Voltage at MPP` V, , [V] 32.30 32.64 32.98 33.32 33.65 33.98 Efficiency' r) [%] _18.1 %18.4 _18.7 _19.0 %19.3 _19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOC' Power at MPP2 PM,,. [W] :'26.0 229.7 233.4 237.2 240.9 244.6 c Short Circuit Current` 1w [Al 8.00 8.05 8.09 8.14 8.18 8.22 Open Circuit Voltage' Vo, [VI 36.80 37.05 37.30 37.54 37.79 38.04 Current at MPP* IMPP IA] 7.43 7.47 7.51 7.56 7.60 7.64 Voltage at MPP* V, , [VI 30.43 30.75 31.07 31.39 31.70 32.01 -1J00 W/m2.25'C,spentru r AM,.SG r Measurement tolerances STC s3%,NOC s 5% 8(=JW,rr" NOCT,ascetic AM 1.50 `typical vai.es.act ial values may differ O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE me oaw ee At least 98%of nominal power during f.rst year. , 10 r - °. ,°v; , � �,� Thereafter max.0.54%degradation,per year. m x °D At least 93.7%of nomnal power up to 10 years. 5 ,00 Al least 85%of nominal power up to 25 years. LL • E.,-, B° All data within measurement tolerances. - Bo--- Full warranties in accordance with the war•anty terms of the()CELLS sales organization of your respective country. Bo ,� ,m eo Mn Boo 1000 IRRADIANCE;Wfrr! . z TO m Topical module performance under low irradiance conditions i., YEARS comparison to STC corditions(25'C,::000 W/rn=). o. TEMPERATURE COEFFICIENTS 4 Temperature Coefficient of ISr a MN) +0.04 Temperature Coefficient of Voc 13 [%/K] -0.28 L. Temperature Coefficient of PMP, y 1%/K1 -0.3/ Normal Operating Cell Temperature NOCT I°FI 113±5.4(45--3°C) F, PROPERTIES FOR SYSTEM DESIGN ',,' 6 Maximum System Voltage Van [V] 1000(IEC)/1000(ULl Safely Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating C(IEC)'TYPE 1(UL) a c Design load,push(UL)2 [Ibs/ft2] 75(3600 Pal Permitted module temperature -407 up to+185'Fzi on continuous duty (-40`C up to+85°C) Design load,pull(UL7 [Ibs/ft2] 55.6(2666Pa) see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ul 1703;VUE Quality Tested;CE.-compliant; Number of Modules per Pallet 32 IEC 61215(Ed.2);IEC 61730(Ed.1)application class A Number of Pallets per 53'Trailer 30 e k V aNumher of Pallets per 40'High Cube Container 26 D E us Pallet Dimensions(L x W x H) 69.3 in x 45.3 in x 46.9in (1760mmx11.50mmx1190mm) Pallet Weight 1415lbs(642 kg) - NOTE:Installation instructions must he followed.See the installation and operating manual or contact our technical serve-ce depadmert for further in`ormaton on approved installation and use - of this product. S Hanwha O CELLS America Inc. 30U Spectrum Cente•Drive.Suite 1250.Irvine,CA 92618,USA I TEL-1 949 748 59 96 I:MAIL inquiry@us.q-cells.con I WEt www.q-cells.us - SolarEdge Power cc solar " i w solar - i i Optimizer 9 N Module Add-On for North America P300/P320/P370 I P400/P405 SolarEdge Power Optimizer p320 P310 P400 RoS fm U4CER PTW Ene.1 h (tor highm putaar SE, ! l 8-Pownr Ib:72Aiefi,cmn ri_+m 40 end"'a wr ktl 60 ell y�tea) mod le I modules) 5i1e5; Module Add-On For North America F— INPUT Rated roof DC Power, 30:! 1 373 0 ? Am ,, AtPTIute Maximum input VONese aE b ... 80 P300 f P320; P3701 P4�a/P405 (Vetstkn csttempemtuTel , Mani Ojttr:8ir.gRunlet S 00 E-00 E Eo i is .OS iir Maximum Short CPcult Cunetu flap 10 10.F ids Minimum PC Input Caned 17 S 1 ... 13.75 12.83 Ad,: CC ., .. Maxlm'rM FOkk=! 44.5 ... �. Wefphted Efficiency S&P , y` OUTPUTOUNING OPERATION itIthsr R OPTIMIZER CONNECTED TO OPERATING 40t AR E OGF INVE RTF R) 'if.' i ^ ' Maximum Output Current Mximum Ou -[Yaltaa LS OUTPUT DURING STANDBY(Pow LR OPTIMIZER DISCONNECTED TROT/Sn1.I,RCLr1E INvERTTP OR cnLgrr a_GGE�'~VERTEA orr) `te CD -Safety Output Waage ow, 4Mc Optimizer s�1., SP" /ti STANDARD EOM1?Pt hNCC {�,� chit I t 3 1 4"kMl Erg It, t 3 r., s Safety _ Iciais a Yes safety), u u 001$ r4i ONnrndt. S 5.../ •'� 4 v m3' Mai ,r n Allowed 5}sle•n lbkaSe ICIY; W e ,,, !" '�` Aa Sol dge Single aje and Three.Phase invenem. .. .s(W at. PO 128a 152e2T :5 s.,.97e 1.9E 12Ex i52x35{ 128a152 a50J �mJ ,.¢ s. Se 5,97 x 1,37 5x 5.97x 1.96 %' '� -. In wligM.no0drng ablesr._...,_,_. 690!14 750117 545/1.9 rip_ Input Connector MCI CompeRfbln a^+ 4{oi AN4 MC4 Compatible Output WItS Spool Connecta' Ocu'Me Insulated;MCI COmpatIole : MC4 j Do bie Insulated,MCA Compatible Amphora'AN4 Output Wire LeOlph ,.. ; 0.9513- 12/3.9 milt :n ' ,Operating Tempera-,4 Rasp !.. .40-+85/-40-+185 'C/'F ill. .Protection Rating !Pali NEMAMP RekMveHumidity? C 100 % FY SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A S EAREDGE 4NVERTER''T HO WAVE (Pmscr OPpmi1Ct51 2 1A Maimum String Length 20 - "; SC PL/power optimization at the module-level (PowerOpti s,n) 57000(130 wdh Malemum Pow*,per ShhgSLSLI ,.. .. __t51 .. . .., ... . SEiHI0h1-U5 i ;uf1Yn (t;IerMy i'3'3.'i"Y..} Px 11.,Shuns of Dirmnrn isrorn YttN M Drienl:dions PI..gates a types of maduie,-sr:t_.,r,_s.-c.from raeobetari-r tolerance to p�rtl-1 thadieg _:,.,w..,.:*,y��--x Pr,.,�.-,M c,ene� «..a ,�:,✓+x«+aereur.4e.*nJ�ew+'.. - tr°Kilslf SpF.tPlti CIBSiF,n fen maximum SiLetC ui -dtl:>r, Fast.int.ta Pat'or with a single bolt - Next gerferation maintenance with;nn;fale.i- 1 MO,ttOt r;R - Modale-leve`-voltage shutdown for installer and hrehghter Safety CE 0 SOLARMOIJNT LJNLAC SOLARMOUNT ::: UNIRA I SOLARMOUNT is the professionals'choice for residential PV mounting applications.Every aspect of the system is designed for an easier,faster installation experience.SOLARMOUNT is a complete solution with "' ''''tRttSir7TITINDOStErSBEST DESIGN TOtu revolutionary universal clamps.FLASHKIT PRO,full system UL 2703 certification and 25-year warranty.Not only is SOLARMOUNT easy to install,hut hest-in-class aesthetics make it the most attractive on any block, I. SYSTirst MANY APrucATtONs ' (O NF4tf"f CI;•'P 00.1 fi,L 47444 e E . fYERY 1UtT M, 9 1. /, vb M ,,,,, /N' any' ,6-' .! E , . 'N1 :,, "_ rF New&Improved- 1. �' THEPROFESSIONALS' H .,_ �r: III, teVittt Suloinr tteskiT kk • trrt • ., . .: Min,„,�,a. 4,< 1 ra;r • A w �- 7 aF. t.:,,?b1ear{EIt C,' illf 4: ,,,' '''''''''''' ":. lteri :.,:.: I .444,"11114.0!1.,.. M.181ril. filiVIN141. 4. ibtopS'', (..7.,.,.). i . . e . :.. y .: .. NOW FEATURING FLASHKIT PRO NOW WITH UNIVERSAL MIUCLAMPS REVOLUTIONARY NEW ENIICLAMPS The Complete Root Attachment Solution Accommodates 30mm.51mm modulo Tames Concealed design and included End Caps ernnci=;,r1C«,.,hasa,e r'raaKemse One toot.one.perenc melells me hem! TF'a+RICAt Y.IfF+Egt 10PfifIfnf1JtllTYf'Ri1H01f0 t'Akk"B5EViMMANTY THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING BESTINSTALLATIONEXPERIENCE•CURBAPPEAL•COMPLETESOLUTION•UNIRACSUPPORT