Loading...
31A-285 (9) 3 JAMES AVE BP-2021-1432 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31 A-285 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1432 Project# JS-2021-002378 Est.Cost: $10010.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VIVINT SOLAR DEVELOPER LLC 062490 Lot Size(sq.ft.): 8929.80 Owner: ROSENBURG HENRY& KATHERINE HICKS Zoning: URB(100)/ Applicant: VIVINT SOLAR DEVELOPER LLC AT: 3 JAMES AVE Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT A - Attn Savina Cervone (413)259-8044 O WC CHICOPEEMA01022 ISSUED ON:6/2/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF MOUNT SOLAR - 14 MODULES 4.55KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTO UPT.. IOLATION OF ANY OF ITS RULES AND REGULATIONS. ` 1I ` Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/2/20210:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner ' J\ \ Department use only City of Northampton:( (I/ S ta't f Permit: Building Department 'r0 / Curb Driveway Permit • 212 Main Street °9T�G ewer/Se is Availability Room 100 ti-s,144., ater II Availability Northampton, MA 01060 \6,1;'/rSA Two ets of Structural Plans phone 413-587-1240 Fax 413-587-12 goo°C, I Site Plans sO her Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address:3 Todut,s Ave_ Map Lot Z.S6 Unit Ir`� 006'd Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 1-1 Z irk I`i3S€ e rCl 3 3 %i es Ave Name(Print J Current Mailing Address: Sow �-{fmac, c\ �(3-ZL2 I(.3S Sl +1RC ccsAi Telephone Signature 2.2 Authorized Agent: kQ Af w 1o1c.aa 150 Padgette St, Chicopee, MA 01022 Name(Prim!) Current Mailing Address: -1_/11L� 413-217-4033 pioneervalleypermits@sunrun.com Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee • 2. Electrical Q �� (b) Estimated Total Cost of O Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total = (1 +2 +3 +4 +5) Check Number /na n This Section For Official Use Only v� Building Permit Number: ps a /.f y3). Date /42 Issued: 9Si nature: 6- 1- 262 Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained © Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES © NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House n Addition ❑ Replacement Windows Alteration(s) Roofing pi Or Doors C] Accessory Bldg. ❑ Demolition ❑ New Signs [mi l?c�ks (0 Siding [CI] Other , I] Solace �•� Brief Description of Proposed Work: Installation of roof mounted photovoltaic solar systems#of modules l4 4.55iCw Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Vivint Solar Developer, LLC , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the �painss and penalties of perjury. .e,ie gaff►' )orke, ) Print Nam / l .6/1/2 Signature of Own r/Agent D toii V ', SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Douglas Caverly CS-062490 License Number 150 Padgette St Unit B, Chicopee, MA 01022 03/02/2022 Address Expiration Date �dII"- 413-259-8044 Signatur Telephone 9.Registered Home Improvement Contractor: Not Applicable 0 VIVINT SOLAR DEVELOPER, LLC/ Douglas Caverly 170848 Company Name Registration Number 1800 W Ashton Blvd, Lehi UT 84043 1/4/2022 Address Expiration Date Telephone 413-259-8044 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 34 No ❑ 11. — Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts Department of Industrial Accidents writ' 1,=�l Office of Investigations • ;.t.I- 1 Congress Street, Suite 100 • i Boston, MA 02114-2017 %zit.va www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Le2ibly Name (Business/Organization/Individual):Vivi nt Solar Developer, LLC c/o Sunrun Inc Address: 225 Bush St, Suite 1400 City/State/Zip:San Francisco, CA 94104 Phone #:628-502-2834 Are you an employer?Check the appropriate box: Type of project(required): 1.[Q I am a employer with 253 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. 0 New construction 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.# required.] 5. ❑ We arc a corporation and its 10.0 Electrical repairs or additions 3.0 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.2 Other Solar Installation comp. insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees.they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employee& Below is the policy and job site information. Liberty Insurance Corporation Insurance Company Name: _ Policy#or Self-ins. Lic. #: WA764D445522020 Expiration Date: 10/1/2021 Job Site Address: 3 1- €0te.2, Ave- City/State/Zip:Ja IVI 7 ,4, / 0(06.0 Attach a copy of the workers' compensation policy declaration page(showing the policy number and txpiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. (?-�' 11/5/2020 Signature: ' Date: Phone#: 628-502-2834 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ®� Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Construction Supervisor CS-062490 Expires:03/02/2022 DOUGLAS P CAVERLY 178 MILLER STREET LUDLOW MA 01056 l t iiti\ I 101 COmmissioner r�lhe WwpmsemstficallA 44.1MrrkMMlieI Offloe of Consumer Affairs d Bualness Regulation HOME IMPROVEMENT CONTRACTOR TYPE:Suooloment Card Registration Exolratlon 170848 01;04,2022 VIVINT SOLAR DEVELOPER LLC DOUGLAS CAVERLY 1800 W ASHTON BLVD LEHI,UT 84043 Undersecretary ��.m.41 SUNRINC-02 JWANG3 ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD YYYY) �� 11/2/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Atsuko Scott NAME: Alliant Insurance Services,Inc. PHONE I FAX 575 Market St,Ste 3600 (A/C,No,Ext): (A/C,No): San Francisco,CA 94105 E-MAIL ADDRESS:Atsuko.Scott@crystalco.com stalco.com INSURERS)AFFORDING COVERAGE NAIC N INSURER A:Navigators Specialty Insurance Company 36056 INSURED INSURER B:Liberty Mutual Fire Insurance Company 23035 Vivint Solar Developer,LLC INSURER C:J am es River Casualty Company 13685 c/o Sunrun,Inc. 225 Bush Street,Suite 1400 INSURER D:Liberty Insurance Corporation 42404 San Francisco,CA 94104 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WVD (MM/DD/YYYYI IMMIDD/YYYY1 A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR LA2OCGL2303211C 11/1/2020 10/1/2021 DAAGEOEoNTEe rice) $ 1,000,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X 1287 LOC PRODUCTS-COMP/OP AGG _$ 2,000,000 X OTHER:Retention: $100,000 Per Project Agg $ 10,000,000 B AUTOMOBILE LIABILITY (COMBIN SINGLE LIMIT $ 2,000,000 X ANY AUTO AS2641445522010 11/1/2020 10/1/2021 BODILY INJURY(Per person) $ — OWNED SCHEDULED _ AUTOSRE�ONLY _ AUTOS BODILY O INJURY(Per accident) $ AUTOS ONLY AUTO ONLY (Pert acccidentDAMAGE $ Liability Ded.: $ 100,000 C _ UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 4,000,000 X EXCESS LIAB ^ CLAIMS-MADE 001072260 11/1/2020 10/1/2021 AGGREGATE $ 4,000,000 DED RETENTIONS 1 $ D WORKERS COMPENSATION X AND EMPLOYERS'LIABILITY Y/N WA764D445522020 11/1/2020 10/1/2021 STATUTE oRH 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached It more span Is required) Workers'Compensation Policy WA764D445522020 Deductible:$500,000. CERTIFICATE HOLDER - CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main Street Northampton,MA 01060 - — AUTHORIZED REPRESENTATIVE N Of: ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD ViVi nit SOlare 1800 W Ashton Blvd. t7 �.11 Lehi, UT 84043 A SUl1Uf1 COMPANY May 27, 2021 Re: Structural Engineering Services Rosenberg Structure 3 James Ave, Northampton, MA S-6653175; CAD Version: 4; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Structure: The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Sections (1 and 2): Dimensional lumber - 2x8 at 19" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 10.35 PSF = Dead Load (roofing/framing) 3.00 PSF = Dead Load (solar panels/mounting hardware) 13.35 PSF =Total Dead Load 20 PSF = Roof Live Load 40 PSF = Ground Snow Load (based on local requirements) Wind speed of 117 mph (based on Exposure Category B -the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). 2. The solar panels are 1Yz" thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. vivint.Solar Page 1 of A SUl1Uf1 COMPANY 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir is 205 lbs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies code requirements verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by mounting hardware manufacturers' testing data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Max Horizontal Spacing (in) 57 38 Cantilever(in) 19 13 D. Summary Based on the above evaluation, with appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2015 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, �ySN OF M'+•s J. Matthew Walsh, PE ' ATT MA License No. 54057 - 13 NO 54057 �c�STEP / SS N /AL 05/27/2021 vivint.Solar Page2of2 A SUl1Uf1 COMPANY 11 PV STRING: ROOF SECTIONS: SYSTEM LEGEND PV SYSTEM SIZE: ��j PV STRING 1=14 MODULES ROOF PLANE 1 SLOPE=30° (N)4.550XW DC 3.800kW AC ROOF PLANE 1 AZIMUTH=132° ROOF 1 MAT=COMPOSITION SHINGLE ROOF PLANE 2 SLOPE=30° AC DISCONNECT IS ACCESSIBLE AND LOCKABLE ROOF PLANE 2 AZIMUTH=222° nNEW EXTERIOR NSF TIED TO UTILITY ROOF 2 MAT=COMPOSITION SHINGLE I I METER 15850792. 8 I EXISTING INTERIOR SUBPANEL I1(N)SMART METER.LOCATED WITHIN 10' OF MSP. I P< M O — !,-,1(N)PV SYSTEM AC DISCONNECT. S / fl(N)1 PV STRING INVERTER: I SE3800H-US 0 O IJ(N)14 JA SOLAR JAM60S17J25/4R MODULES WITH P370 OPTIMIZERS 0 MOUNTED ON THE BACK OF EACH MODULE. p m(N)JUNCTION BOX. 70(MOUNTED WITH SOLADECK) Q IEXISTING ATTACHED Lair( METER(15650792) O ® %%% 0 ''///// . i.''/4 1 vivint.Solar' A sunrun COMPANY 1800 ASHTON BLVD.LEHI,UT.84043 1.877.404.4129 MA UC:17E348115608A 3 JAMES AVE FRONT OF HOUSE. ROSENBERG RESIDENCE 3 JAMES AVE N NORTHAMPTON,MA 01060 Pal UTILITY ACCOUNT.90692-34018 METER.15650792 SITE PLAN St/ PV 1 °0 DRAWN BY.DIN A SCALE:1/8'=1-0" DATE 05/262021 / REVISION:0 +i MOUNTING NOTES ROZMT COUPLING MOCINP ROCKJT COUPLING Aft MID CLAMPXV \, • CrE 1 " ROCK-IT 3.0 COUPLING ITO ' ROCK-IT SLIDE MID CLAMP ROSIN 0 PEDESTAL METAL ® ROCKJT L1811R' •�' FLASHING COUPLNG SHELF ' HEX FLANGE BOLT BM 3005ENES SS 411r,y1. ROCK4T COUPLING SHELFL401.4IRIC VIEW �/ \I COMP SHINGLES `t f ASS LAG SCREW � TOROUE.13t2 FT-LBS. ♦, \\\\\ SIDE VIEW 1 L16111? TE PLATE HEX FLANGE BOLT 1 ROCK-IT 3.0 MOUNT DETAILB LSCO SGB-4 GROUNDING LUGS SIDE VIEW 300 SERIES SS O 0 O 51.0 NOT TO SCALE S 1.0 NOT TO SCALE GI_LIMAS FOR ECOFABTEN:IM 2 ROCK-IT 3.0 COUPLING ASSEMBLY WEIGHT 2.36. S 1.0 NOT TO SCALE TOP VEw MAX MOUNT SPACING LANDSCAPE MOUNT SPACING=57' CLAMP.ATTACHMENT.rw LANDSCAPE CANTILEVER=19' r CLAMP.ATTACHMENT,TYP PORTRAIT MOUNT SPACING=38' TYP PERMITTED / f COUPL INC,TYP PORTRAIT CANTILEVER=13' ILEUM:SEE MOUNTING NOTES I I CIMIP SPACING I/ MOUNT SPACING.SEE '• w- MOUNTING NOTES COUPLING CLAMP FRAMING TYP MODULE,TIP - ROCWIT SLOE MODULE METAL MOOULE,TYP FLASHING EPOM BONDED WASHER FORMS WATERTIGHT SEAL ^FRAMING.TYP FRAMING.TYP I I LKLANOSCAPECLAMP SPACES y ...� •4 PV SYSTEM MOUNTING DETAIL 5 MODULES IN PORTRAIT/LANDSCAPE I I L°PORTRAIT S 1,0 NOT TO SCALE S 1.0 NOT TO SCALE CLAMP SPACED COMP SHINGLES 2-? 3•MIN AND 8'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MIN SUB'DIM ONE HOLE STEEL STRAP CONDUIT SS LAG SCREW PH MODULE,TVP.40U LT Alk TORQUE-13:2 FT-LBS. TO FRAMING OF EXETNG NV ROOF TYPE.PARALLEL F�/���/� WITH PLANE OF ROOF - - _ CONDUIT MOUNT BRACKET vivin .Solar B'MAXIMUM L_ ASunrunCOM^ANC 1 BOD ASHTON BLVD.LEHI,UT,840M3 SECTION VIEW '�•"_ t t 1.877.404.4129 FLASHING OR TILE STRAP MALC:170848 1158B8A I ROSENBERG RESIDENCE 3 3 JAMES AVE SECTION VIEW NORTHAMPfON,MA 011180 S to NOT TO SCALE 6 PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:9069231018 S 1.0 NOT TO SCALE S 1 0 NOT TO SCALE METER.15850792 J MOUNT DETAILS SB S-8853175 ROC:MA-04 S 1 .0 M DRAWN BY.DIN A SCALE NOT TO SCALE DATE 05/282021 REVISION.0 +M 4 i ROOF INFORMATION FRAMING INFORMATION ATTACHMENT INFORMATION MOUNT LEGEND ROOF MAX LANDSCAPE MAX LANDSCAPE MAX PORTRAIT MAX PORTRAIT RAFTER SECTION TYPE TYPE SPACING MOUNT DETAIL CONFIG. MOUNTING FEET a SPACING CANTILEVER SPACING CANTILEVER RS 1 COMPOSITION SHINGLE RAFTER 20' ECOFASTEN ROCK-IT 60'OC 20" 40'OC 13" STAGGERED RS 2 COMPOSITION SHINGLE RAFTER 20' ECOFASTEN ROCK-IT 60"OC 20" 40'OC 13' STAGGERED -,101$" ,- 34" --1,- 34' —II O i O • T • • 34' 34" 3'4" 3'-4" 3'4' i‘ • • 34" 34" vrvint.Solar • • A SUl1BI8L CORM PA I Nv 1800 ASHTON BLVD.LEHI,UT,84043 1.877.404A129 1'-3" 1'-8" MA LTC:170648115688A ROSENBERG RESIDENCE 3 JAMES AVE Zi NORTHAMPTON,MA 01060 ' UTILITY ACCOUNT 90692-34018 g. METER 15050792 y MOUNTING DIAGRAM Stt OCM�S S 1.01a DRAWN BY.DIN A SCALE:1/4"=1'-0" DATE:05/262021 = REVISION:0 3 Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 4550 Tag Description Wire Gauge 4 of Conductors/Color Conduit Type Conduit Size co AC System Size(Watts) 3800 1 DC-to-DC Converter Output(PP Wire) 10 AWG 2(V.,V-)B/R Free Air N/A of o m Total Module Count 14 1 EGC(Bare) 6 AWG 1 BARE Free An N/A w o N 2 DC-to-DC Converter Output(THWN-2) 12 AWG 2(V.,V-)B/R FMC 1/2" w Q < o 2 EGC(THWN-2) 12 AWG 1(GRN) FMC 1/2" cc w o' c,.:,23 DC-to-DC Converter Output(THWN-2) 12 AWG 2(V.,V-)B/R EMT 1/2" y C n c 3 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" c m E 4 Inverter Output(THWN-2) 12 AWG 3(L1,L2,N)B/R/W EMT 1/2" p t Q a C > 4 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" Z , 7 ` Y v z a o a CO • o I V Cc c N b Z7 N N U Or ni g r., SolarEdge SE3800H-US PV System SMART Meter g 'Conforms to ANSI 0 .`.1{. C12.1-2008 Point of Interconnection,Load Side of 705.12(e)(1)Ibl&(B)(2) Z m Q Square D DU221RB 5 j m 240V/30A Unfused, Existing > Z to NEMA3R,with 75'C Square D D221NRB 240V/100ApanelSub New 240V/100A Service Panel,Single cc w 240V/30AFused, Panel Phase,with 100A Main Disconnect J —,� • / Terminations NEMA3R,with 75'C Main Disconnect isconRapid Shutdown J m m / ,,....,- terminations Disconnect vans or (0 SHEET }/ 100A NAME: sl t LINE r..�'�— ��/� C �� a,., I T ( • l)' EXISTING ySTRING 1:14 PV 0 © • 7 ` 100AjAMODULES NEMA 3R Junction Box ,,iice� 4 L•" CO M 6' W/OPTIMIZERS . .••• U 0 O 20A }} tv/ SHEET IL I I �' NUMBER: 1—= r p sil 14 PV MODULES PER INVERTER=4550 WATTS RNi p Y STC Vlsible/Lockable'Knife'AC Vislble/Lockable'Knife AC Minimum GEC size 6 Disconnect Disconnect,In Sight of Tap AWG copper LLI t f $ Inverter/Optimizer Specs PV Module Rating @ STC Conductor Calculations m Optimizer SolarEdge P370 Module Make/Model JA Solar JAM60517-325/MR Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature g g DC Input Power 370 Watts Max.Power-Point Current(Imp) 9.57 Amps F, 8calculations from Table 310.15(B)(1)&310.15(B)(2)and raceway fill adjustments from 310.15(C) w DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.97 Volts '4 i < 01 (1).Conduit on the roof shall be installed no less than 1"above the roof deck. d < 2 0 DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Voc) 40.87 Volts PV Circuit conductor ampacity is constrained using the 75'C column with the continuous duty z a] =O1 DC Max.Output Current 15 Amps Short-Circuit Current(Ise) 10.23 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments `- 0 n = Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. c m E 8 Inverter Make/Model SolarEdge SE3BOOH-US Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90'C column with the $ t < CEC Efficiency 99 % Max.System Voltage 1000V/1500V DC(UL) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& Vs z '— AC Operating Voltage 240 Volts Voc Temperature Coefficient -0.272 I %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, 5 Cont.Max Output Current 16 Amps the continuous duty uprated current. DC Max Input Current 10.5 Amps ASHRAE 2017-WESTOVER METRO More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:33'C Calc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor x Conduit Fill Adj.Factor>=Output Current Max Output Fault Current 17.5 A/20 ms Lowest Min.Mean Extreme D.B.:-28'C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A L >. (Tag 2 Attic): _0 Z DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A C) a (Tag 3 On Roof): F DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A 4.: OU (Tag 4 Exterior): ^ Inverter Output:12 AWG rated 20 A, 20 A>=20 A i S pima .... .r . C i, < - v s" m m LJ rV a Other Notes 8 •Designed according to and all code citations are relevant to the 2020 National Electrical Code. w r^. •All interior raceways carrying DC current shall be metallic. g a0 O anz.. Voltage and OCPD Calculations(690.7,690.9) '> Z N area PV Source Max Circuit Voltage:Module Voc x(1-(AT x Voc Coeff))[art.690.7(A)] -1 m r. JAM6OS17-325/MR:40.87 V x(1-((25 C—-28 C)x-0.272%))=46.76 V<=60 V < r x en z z a 1, 0 Inverter Output Circuit(s):Listed Output Current x 1.25[art 690.9(8)] SHEET Inverter 1:SE3800H-US Max Output=16 A x 1.25=20 A<=20 A(OCPD) NAME: System output current w/continuous duty=20 A<=20 A(System OCPD) I41 m Z a SHEET NUMBER: eV W DocuSign Envelope ID:952643B3-2F3B-4456-B313-BBB1 E95B7C0C Vivint Solar BrightSaveTM Agreement Take Control of Your Electric Bill SO Years $ 2.6 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today One (plus taxes, if applicable; (excluding upfront includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE C;) fin) We provide hassle-free We monitor the system We warrant, insure, Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 4.sso kW DC Solar System With 14 Solar Panels Which will produce an est. 4835.624 kWh in its first year And offset approx. 118 % of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Gina Ramos gina.ramos@sunrun.com DocuSign Envelope ID:952643B3-2F3B-4456-B313-BBB1E95B7C0C By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. VIVINT SOLAR DEVELOPER, LLC Signature: Gsco. 4444 Print Name: Karen De Jesus Date: 05/20/2021 Title: 9502303 Federal Employer Identification Number: 80-0756438 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO VIVINT SOLAR DEVELOPER, LLC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE ' NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH DAY AFTER THE EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer Prim AccAuRt Holder Secondary Account Holder (Optional) 3DA406 Signature May 20,2021 I 12:26 PM PDT Date Print Name Email Address*:hwr5@comcast.net Mailing Address: 3 James Ave Northampton MA 01060 Phone: 4132211135 `Email addresses will be used by Vivint Solar for official correspondence, such as sending monthly bills or other invoices. Sales Consultant By signing below I acknowledge that/am Vivint Solar accredited, that I presented this agreement according to tiie—ldtiviig#„S0,1ar Code of Conduct, and that I obtained the homeowner's signature on this agreement. 8 lM562A4CF_. Gina Ramos`` Print Name 211151 Vivint Solar ID number Vivint Solar Developer, LLC 11800 W Ashton Blvd., Lehi, UT 84043 1877.404.4129 Contract Version: 2020Q4VS Generation Date: 10/5/2020 21