31A-173 (3) e) N!'tiAJA- D REUSE 6 iN f`) (-SU) - l 73
Home Energy Rating Certificate Rating Date: 2019-07-01
Projected Report Registry ID:
Ekotrope ID: Pda5l_ed
HERS® Index Score: Annual Savings Home:78 Maynard Rd
Your home's HERS score is a relative
performance score.The lower the number, $ 3
518
Northampton, MA 01060
the more energy efficient the home.To5
Builder:
learn more,visit www.hersindex.com *Relative to Air
an average U.S.home Renaissance Builders
Your Home's Estimated Energy Use: This home meets or exceeds the
Use[MBtu1 Annual Cost criteria of the following:
Heating 66.3 $952 2015 International Energy Conservation Code
Cooling 1,8 $110
Hot Water 2.7 $165
Lights/Appliances 22.4 $1,381
Service Charges $264
Generation (e.g.Solar) 0.0 $0
Total: 93.2 $2,872
HERS Index Home Feature Summary: Rating Completed by:
.. Mei,Fne*gy Home Type: Single family detached
Energy Rater:Jamie Callan
,w Model: N/A
Existing too Community: N/A RESNET ID3463906
Horses "° RatingComa Riverbend Design,LLC
Conditioned Floor Area: 2,836 ft2 �' g
120 151 Riverside Drive,Florence,MA 01062
Reference no Number of Bedrooms: 3 $13 923 1553
Home t 100 Primary Heating System: Furnace•Natural Gas•97 AFUE
e" Primary Cooling System: Air Conditioner•Electric•16 SEER Rating Provider:Energy Raters of Massachusetts
gtl 2 Wood lawn Street Amesbury,MA 01913
Primary Water Heating: Water Heater•Electric•3.69 Energy Factor 978_270-3911 '°w ••,
r
House Tightness: 2 ACH50 ,d s
_ ram i;_
so Ventilation: 80 CFM•84 WattNa,,,,
40 This Ham*
ao Duct Leakage to Outside: 0 CFM @ 25Pa(0/100 s.f.) a -" cIPS
`� Cat tan,
„
as Above Grade Walls: R-18 LI�i17i(i? C {,�.t'L
Zero Ener w Ceiling: Vaulted Roof,R-56
Home 0 Window Type: U-Value:0.28,SHGC:0.3 Jamie Callan,Certified Energy Rater
eion esw= Lea WNW Foundation Walls: R 16 Digitally signed:3/6/20 at 6:27 AM
ilk ekotro e Ekotrope RATER-Version-3.1.12380
The Energy Rating Disclosure for this home is available from the Approved Rating Provider.
This re ort does not constitute an, warran or•uarantee.
IECC 2015 Label
78 Maynard Rd
Ekotrope RATER-Version: 3.1.1.2380
,, ,.
Ceiling: R-56
Above Grade Walls: R-18
Foundation Walls: R-16
Exposed Floor: N/A
Slab: R-10
Infiltration: 2 ACH50
Duct Insulation: R-6
Duct Lkg to Outdoors: 0 CFM @ 25Pa (0/ 100
s_f.)
U-Value: 0.28, SHGC:0.3
Door: R-3
•
Heating: Furnace • Natural Gas • 97 AFUE
Cooling:Air Conditioner• Electric • 16 SEER
Hot Water: Water Heater• Electric• 3.69 Energy
Factor
Signature:
RESNET HOME ENER Y
RATING Standard Disclosure
For home(s) located at: 78 Maynard Rd, Northampton, MA
Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page:
The Rater or the Raters employer is receiving a fee for providing the rating on this home.
12. In addition to the rating, the Rater or the Raters employer has also provided the following consulting services
for this home:
A. Mechanical system design
L B. Moisture control or indoor air quality consulting
C. Performance testing and/or commissioning other than required for the rating itself
Li D. Training for sales or construction personnel
E: E. Other(specify)
93. The Rater or the Raters employer is:
•IA. The seller of this home or their agent
fl B. The mortgagor for some portion of the financed payments on this home
':C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
Fr14. The Rater or Raters employer is a supplier or installer of products, which may include:
Products Installed in this home by OR is in the business of
HVAC systems Li Rater L Employer Rater Employer
Thermal insulation systems EiRater nEmployer LiRater FlEmployer
Air sealing of envelope or duct systems DRater FlEmployer FeiRater ilEmployer
Energy efficient appliances Rater rtEmployer FiRater Employer
Construction(builder, developer, construction contractor, etc) :Rater Li'mEmployer Rater rlEmployer
Other(specify): 7Rater lEmployer FiRater nEmployer
5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET), Rater Certification #: 3463906
Name: Jamie Callan Signature: Jante.:e Caffai)
Organization: Riverbend Design, LLC Digitally signed: 3/6/20 at 6:27 AM
I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http:!!resnet.us/standards/RESN ET Mortgage Industry National HERS Standardspdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007
Renaissance
Builders
PO Box 272,Turners Falls.MA 01376
Phone(413)863-8316;Fax(413) 863-9712
www.renbuild.net
Louis Hasbrouck
Building Commissioner
City Of Northampton
78 Maynard Street- Proposed insulation values
1. All walls on first Floor to be gutted and receive Dry — Pac Cellulose full depth of
stud bay 3-3/4" from the interior with netting and smart membrane
2. Existing house second floor walls which are not being gutted to receive Dry—
Pac Cellulose full depth of stud bay 3-3/4" Drilled from the exterior
3. Existing windows opening on First and second floor on West side to receive
replacement windows. Weight Pockets to be filled with foam
4. Both new and existing cellar walls to receive 2-1/2" Thermax - R-18
5. Under slab in new cellar to receive 2" XPS R -10 on top of 15 Mil vapor
barrier
6. New addition walls to receive Dry — Pac Cellulose full depth of stud bay 5-1/2"
from the interior with netting and smart membrane.
7. Hot Roof— Underside of all new and existing rafters to receive 8" Demilec
Heatlok Closed Cell Foam - R-60 includes 1" over interior face of rafter to
eliminate transfer
8. Rim Joists — Both floors rafters to receive 4" Demilec Heatlok Closed Cell
Foam
9.1" Polyiso R -5 over all exterior sheathing
10. U value of windows 0.28
11. All sheathing on new addition to be Zip system with tape at all seams and
corners.
12. Existing board sheathing on house that remains to receive Henry Blue Skin or
equal
RSE ASSOCIATES Inc .
• 63 Pleasant Street,Suite 300,Watertown, MA 02472 Tel(617)926-9300
March 5, 2020
Tim Stewart
Eck I MacNeely Architects Inc.
560 Harrison Avenue
Suite 403
Boston,MA 02118
Re: 78 Maynard Rd, Northampton, MA oio6o
Dear Tim,
This letter is to inform you that the roof framing at the above referenced project has been designed to
accommodate the additional loading from solar panels.An allowance of 5psf was included in the design
of all roof framing to account for the possibility of solar panels being added at a future date.
Yours truly,
(.3A,HOF446,0,10
� o� RICHMOND yG
o� STRUCTURAL y
No.42696
Q
SOT ISM
���
FSS/ONAL 041
Richmond So, PE
Boston London Los Angeles New York
carrier
SUBMITTAL
Project
78 Maynard Street
Date
Friday, March 6, 2020
Table Of Contents
Project:78 Maynard Street 03/06/202C
Prepared By:
Split System Furnace 3
Unit Report 4
Performance Summary 6
System Parameters 6
Electrical Data 6
Acoustic Summary 7
Certified Drawing 8
Unit Feature Sheet 11
Infinity Controls 14
ERV 20
Note: Please confirm damper sizes.
Residential Carrier Products Bldr 1.29n Page 2 of 13
Split System Furnace
Project: 78 Maynard Street 03/06/202f
Prepared By:
Split System Furnace
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Feature Sheet
Residential Carrier Products Bldr 1.29n Page 3 of 13
Unit Report For Split System Furnace
Project: 78 Maynard Street 03/06/202C
Prepared By:
NO
HMO
MIL
kk ROW
fi
Outdoor Unit Parameters Indoor Coil Parameters
Unit Model. 24ANB Unit Model: CNPV
Unit Size. 3 Tons(Size 36) Unit Size. 3 Tons(Size 36)
Voltage. 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted
Cabinet Width. 17 inch
Refrigerant Type: Puron
Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight
Unit Length 31.1875 in Unit Length. 21 in
Unit Width: 31.1875 in Unit Width. 17.5 in
Unit Height: 36 in Unit Height: 17 in
Unit Shipping Weight 275. lb Unit Shipping Weight 48.5 lb
RESIDENTIAL APPLICATIONS
This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and
below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below.
Limited Warranty(Years)
Item Original Owner Subsequent Owner
Parts 10*(or 5) 5
Compressor 10*(or 5) 5
*If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that
prohibit warranty benefits conditioned on registration).See Warranty Conditions below.
OTHER APPLICATIONS
The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is
not available for subsequent owners.
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ANB736A003 Infinity Series Two-Stage Air Conditioner w/Puron 3 Tons Cooling 1
17 SEER @ ARI Conditions
Accessories
SYSTXCCITC01-B Infinity Touch Wi-Fi Control for Outdoor Unit 1
SYSTXCCSMS01-B Infinity Smart Sensor for Outdoor Unit 2
Indoor Coil
CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1
Painted
17 inch
Aluminum
Furnace
59TN6B060C17--14 59TN6 Infinity+96 Two Stage Condensing Gas Furnace 1
+96 AFUE
60,000 Btuh (Size 060)
Residential Carrier Products Bldr 1.29n Page 4 of 13
Unit Report For Split System Furnace
Project: 78 Maynard Street 03/06/202C
Prepared By:
Up to 1400 Clg CFM on Evap Coil
Comm.Variable Speed
17.5 inches
Furnace Parameters and Dimensions and Weight
Furnace: SEER Enhancing Furnace
Furnace Model: 59TN
Furnace Efficiency: +96 AFUE
Htg Capacity:60,000 Btuh (Size 060)
Airflow: Up to 1400 CIg CFM on Evap Coil
Unit Length: 29.50 in
Unit Width: 17.50 in
Unit Height: 35.00 in
Unit Shipping Weight: 151. lb
v
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Residential Carrier Products Bldr 1.29n Page 5 of 13
Performance Summary For Split System Furnace
Project: 78 Maynard Street 03/06/202C
Prepared By:
System Performance
System: 24ANB/CNPV Actual Clg Airflow: 1200.0 CFM
System Quantity• 1 Standard Clg Airflow: 1200.0 CFM
Altitude: 0.0 ft Total Net Clg Capacity: 35.29 MBH
Furnace Type: 59TN6B060C17**14 Net Sensible Clg Capacity: 26.10 MBH
Linear Pipe Length: 50.0 ft Total System Power: 2.79 kW
SEER @ ARI Conditions. 15.0
EER @ ARI Conditions: 12.5
System Parameters
Outdoor Unit Parameters Indoor Coil Parameters
Unit Model. 24ANB736A003 Unit Model: CNPVP3617ALA
Unit Size(Nominal): 3 Tons(Size 36) Unit Size(Nominal): 3 Tons(Size 36)
Voltage- 208/230-1-60 V-Ph-Hz Ent Air DB: 80.00 °F
Clg Ent Air DB Ambient. 95.0 °F Ent Air WB. 67.00 °F
Ent Enthalpy. 31.44 BTU/lb
Lvg Air DB: 59.86 °F
Lvg Air WB: 57.80 °F
Lvg Enthalpy: 24.90 BTU/lb
Total External Static Pressure- 0.20 in wg
Furnace Ratings Furnace Performance
Furnace. 59TN6B060C17--14 Certified Temp High Rise Range. 35-65 F
Furnace Efficiency. +96 AFUE Certified Temp Low Rise Range: 30-60 F
Furnace Efficiency ICS- 96.3 AFUE
Input Max Heat. 60,000 BTU/hr
Input Min Heat. 39,000 BTU/hr
Output Max Heat: 58,000 BTU/hr
Output Min Heat: 38,000 BTU/hr
The customer must ensure :•Derihed airflow and static pressure are within furnace capabilities.
Electrical Data
Outdoor Electrical Data Furnace Electrical Data
Unit Voltage: 208/230-1-60 V-Ph-Hz Unit Voltage. 115-1-60 V-Ph-Hz
Fan Motor FLA: 0.70 Amps Unit MCA• 9.3 Amps
MCA: 19.8 Amps Unit MOCP: 15 Amps
Max Fuse: 35 Amps
Operating Range Min: 197 V
Operating Range Max: 253 V
Compressor RLA. 15.3 Amps
Compressor LRA• 83.0 Amps
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Residential Carrier Products Bldr 1.29n Page 6 of 13
Acoustic Summary For Split System Furnace
Project: 78 Maynard Street 03/06/202C
Prepared By:
Outdoor Unit Parameters:
Unit Model- 24ANB
Unit Size- 3 Tons(Size 36)
Variations: Standard
Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 53.0 59.0 64.5 64.5 61.5 59.5 52.5
A-Weighted Sound Power,dBA 70.0
Indoor Coil Parameters:
Unit Model: CNPV
Unit Size: 3 Tons(Size 36)
Cabinet Finish: Painted
Cabinet Width: 17 inch
No Indoor sound data available.
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Residential Carrier Products Bldr 1.29n Page 7 of 13