Loading...
31A-173 (3) e) N!'tiAJA- D REUSE 6 iN f`) (-SU) - l 73 Home Energy Rating Certificate Rating Date: 2019-07-01 Projected Report Registry ID: Ekotrope ID: Pda5l_ed HERS® Index Score: Annual Savings Home:78 Maynard Rd Your home's HERS score is a relative performance score.The lower the number, $ 3 518 Northampton, MA 01060 the more energy efficient the home.To5 Builder: learn more,visit www.hersindex.com *Relative to Air an average U.S.home Renaissance Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu1 Annual Cost criteria of the following: Heating 66.3 $952 2015 International Energy Conservation Code Cooling 1,8 $110 Hot Water 2.7 $165 Lights/Appliances 22.4 $1,381 Service Charges $264 Generation (e.g.Solar) 0.0 $0 Total: 93.2 $2,872 HERS Index Home Feature Summary: Rating Completed by: .. Mei,Fne*gy Home Type: Single family detached Energy Rater:Jamie Callan ,w Model: N/A Existing too Community: N/A RESNET ID3463906 Horses "° RatingComa Riverbend Design,LLC Conditioned Floor Area: 2,836 ft2 �' g 120 151 Riverside Drive,Florence,MA 01062 Reference no Number of Bedrooms: 3 $13 923 1553 Home t 100 Primary Heating System: Furnace•Natural Gas•97 AFUE e" Primary Cooling System: Air Conditioner•Electric•16 SEER Rating Provider:Energy Raters of Massachusetts gtl 2 Wood lawn Street Amesbury,MA 01913 Primary Water Heating: Water Heater•Electric•3.69 Energy Factor 978_270-3911 '°w ••, r House Tightness: 2 ACH50 ,d s _ ram i;_ so Ventilation: 80 CFM•84 WattNa,,,, 40 This Ham* ao Duct Leakage to Outside: 0 CFM @ 25Pa(0/100 s.f.) a -" cIPS `� Cat tan, „ as Above Grade Walls: R-18 LI�i17i(i? C {,�.t'L Zero Ener w Ceiling: Vaulted Roof,R-56 Home 0 Window Type: U-Value:0.28,SHGC:0.3 Jamie Callan,Certified Energy Rater eion esw= Lea WNW Foundation Walls: R 16 Digitally signed:3/6/20 at 6:27 AM ilk ekotro e Ekotrope RATER-Version-3.1.12380 The Energy Rating Disclosure for this home is available from the Approved Rating Provider. This re ort does not constitute an, warran or•uarantee. IECC 2015 Label 78 Maynard Rd Ekotrope RATER-Version: 3.1.1.2380 ,, ,. Ceiling: R-56 Above Grade Walls: R-18 Foundation Walls: R-16 Exposed Floor: N/A Slab: R-10 Infiltration: 2 ACH50 Duct Insulation: R-6 Duct Lkg to Outdoors: 0 CFM @ 25Pa (0/ 100 s_f.) U-Value: 0.28, SHGC:0.3 Door: R-3 • Heating: Furnace • Natural Gas • 97 AFUE Cooling:Air Conditioner• Electric • 16 SEER Hot Water: Water Heater• Electric• 3.69 Energy Factor Signature: RESNET HOME ENER Y RATING Standard Disclosure For home(s) located at: 78 Maynard Rd, Northampton, MA Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page: The Rater or the Raters employer is receiving a fee for providing the rating on this home. 12. In addition to the rating, the Rater or the Raters employer has also provided the following consulting services for this home: A. Mechanical system design L B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself Li D. Training for sales or construction personnel E: E. Other(specify) 93. The Rater or the Raters employer is: •IA. The seller of this home or their agent fl B. The mortgagor for some portion of the financed payments on this home ':C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home Fr14. The Rater or Raters employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems Li Rater L Employer Rater Employer Thermal insulation systems EiRater nEmployer LiRater FlEmployer Air sealing of envelope or duct systems DRater FlEmployer FeiRater ilEmployer Energy efficient appliances Rater rtEmployer FiRater Employer Construction(builder, developer, construction contractor, etc) :Rater Li'mEmployer Rater rlEmployer Other(specify): 7Rater lEmployer FiRater nEmployer 5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET), Rater Certification #: 3463906 Name: Jamie Callan Signature: Jante.:e Caffai) Organization: Riverbend Design, LLC Digitally signed: 3/6/20 at 6:27 AM I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http:!!resnet.us/standards/RESN ET Mortgage Industry National HERS Standardspdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 -Amended April 24, 2007 Renaissance Builders PO Box 272,Turners Falls.MA 01376 Phone(413)863-8316;Fax(413) 863-9712 www.renbuild.net Louis Hasbrouck Building Commissioner City Of Northampton 78 Maynard Street- Proposed insulation values 1. All walls on first Floor to be gutted and receive Dry — Pac Cellulose full depth of stud bay 3-3/4" from the interior with netting and smart membrane 2. Existing house second floor walls which are not being gutted to receive Dry— Pac Cellulose full depth of stud bay 3-3/4" Drilled from the exterior 3. Existing windows opening on First and second floor on West side to receive replacement windows. Weight Pockets to be filled with foam 4. Both new and existing cellar walls to receive 2-1/2" Thermax - R-18 5. Under slab in new cellar to receive 2" XPS R -10 on top of 15 Mil vapor barrier 6. New addition walls to receive Dry — Pac Cellulose full depth of stud bay 5-1/2" from the interior with netting and smart membrane. 7. Hot Roof— Underside of all new and existing rafters to receive 8" Demilec Heatlok Closed Cell Foam - R-60 includes 1" over interior face of rafter to eliminate transfer 8. Rim Joists — Both floors rafters to receive 4" Demilec Heatlok Closed Cell Foam 9.1" Polyiso R -5 over all exterior sheathing 10. U value of windows 0.28 11. All sheathing on new addition to be Zip system with tape at all seams and corners. 12. Existing board sheathing on house that remains to receive Henry Blue Skin or equal RSE ASSOCIATES Inc . • 63 Pleasant Street,Suite 300,Watertown, MA 02472 Tel(617)926-9300 March 5, 2020 Tim Stewart Eck I MacNeely Architects Inc. 560 Harrison Avenue Suite 403 Boston,MA 02118 Re: 78 Maynard Rd, Northampton, MA oio6o Dear Tim, This letter is to inform you that the roof framing at the above referenced project has been designed to accommodate the additional loading from solar panels.An allowance of 5psf was included in the design of all roof framing to account for the possibility of solar panels being added at a future date. Yours truly, (.3A,HOF446,0,10 � o� RICHMOND yG o� STRUCTURAL y No.42696 Q SOT ISM ��� FSS/ONAL 041 Richmond So, PE Boston London Los Angeles New York carrier SUBMITTAL Project 78 Maynard Street Date Friday, March 6, 2020 Table Of Contents Project:78 Maynard Street 03/06/202C Prepared By: Split System Furnace 3 Unit Report 4 Performance Summary 6 System Parameters 6 Electrical Data 6 Acoustic Summary 7 Certified Drawing 8 Unit Feature Sheet 11 Infinity Controls 14 ERV 20 Note: Please confirm damper sizes. Residential Carrier Products Bldr 1.29n Page 2 of 13 Split System Furnace Project: 78 Maynard Street 03/06/202f Prepared By: Split System Furnace Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Residential Carrier Products Bldr 1.29n Page 3 of 13 Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/202C Prepared By: NO HMO MIL kk ROW fi Outdoor Unit Parameters Indoor Coil Parameters Unit Model. 24ANB Unit Model: CNPV Unit Size. 3 Tons(Size 36) Unit Size. 3 Tons(Size 36) Voltage. 208/230-1-60 V-Ph-Hz Cabinet Finish: Painted Cabinet Width. 17 inch Refrigerant Type: Puron Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Unit Length 31.1875 in Unit Length. 21 in Unit Width: 31.1875 in Unit Width. 17.5 in Unit Height: 36 in Unit Height: 17 in Unit Shipping Weight 275. lb Unit Shipping Weight 48.5 lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below. Limited Warranty(Years) Item Original Owner Subsequent Owner Parts 10*(or 5) 5 Compressor 10*(or 5) 5 *If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration).See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 24ANB736A003 Infinity Series Two-Stage Air Conditioner w/Puron 3 Tons Cooling 1 17 SEER @ ARI Conditions Accessories SYSTXCCITC01-B Infinity Touch Wi-Fi Control for Outdoor Unit 1 SYSTXCCSMS01-B Infinity Smart Sensor for Outdoor Unit 2 Indoor Coil CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1 Painted 17 inch Aluminum Furnace 59TN6B060C17--14 59TN6 Infinity+96 Two Stage Condensing Gas Furnace 1 +96 AFUE 60,000 Btuh (Size 060) Residential Carrier Products Bldr 1.29n Page 4 of 13 Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/202C Prepared By: Up to 1400 Clg CFM on Evap Coil Comm.Variable Speed 17.5 inches Furnace Parameters and Dimensions and Weight Furnace: SEER Enhancing Furnace Furnace Model: 59TN Furnace Efficiency: +96 AFUE Htg Capacity:60,000 Btuh (Size 060) Airflow: Up to 1400 CIg CFM on Evap Coil Unit Length: 29.50 in Unit Width: 17.50 in Unit Height: 35.00 in Unit Shipping Weight: 151. lb v The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29n Page 5 of 13 Performance Summary For Split System Furnace Project: 78 Maynard Street 03/06/202C Prepared By: System Performance System: 24ANB/CNPV Actual Clg Airflow: 1200.0 CFM System Quantity• 1 Standard Clg Airflow: 1200.0 CFM Altitude: 0.0 ft Total Net Clg Capacity: 35.29 MBH Furnace Type: 59TN6B060C17**14 Net Sensible Clg Capacity: 26.10 MBH Linear Pipe Length: 50.0 ft Total System Power: 2.79 kW SEER @ ARI Conditions. 15.0 EER @ ARI Conditions: 12.5 System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model. 24ANB736A003 Unit Model: CNPVP3617ALA Unit Size(Nominal): 3 Tons(Size 36) Unit Size(Nominal): 3 Tons(Size 36) Voltage- 208/230-1-60 V-Ph-Hz Ent Air DB: 80.00 °F Clg Ent Air DB Ambient. 95.0 °F Ent Air WB. 67.00 °F Ent Enthalpy. 31.44 BTU/lb Lvg Air DB: 59.86 °F Lvg Air WB: 57.80 °F Lvg Enthalpy: 24.90 BTU/lb Total External Static Pressure- 0.20 in wg Furnace Ratings Furnace Performance Furnace. 59TN6B060C17--14 Certified Temp High Rise Range. 35-65 F Furnace Efficiency. +96 AFUE Certified Temp Low Rise Range: 30-60 F Furnace Efficiency ICS- 96.3 AFUE Input Max Heat. 60,000 BTU/hr Input Min Heat. 39,000 BTU/hr Output Max Heat: 58,000 BTU/hr Output Min Heat: 38,000 BTU/hr The customer must ensure :•Derihed airflow and static pressure are within furnace capabilities. Electrical Data Outdoor Electrical Data Furnace Electrical Data Unit Voltage: 208/230-1-60 V-Ph-Hz Unit Voltage. 115-1-60 V-Ph-Hz Fan Motor FLA: 0.70 Amps Unit MCA• 9.3 Amps MCA: 19.8 Amps Unit MOCP: 15 Amps Max Fuse: 35 Amps Operating Range Min: 197 V Operating Range Max: 253 V Compressor RLA. 15.3 Amps Compressor LRA• 83.0 Amps The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29n Page 6 of 13 Acoustic Summary For Split System Furnace Project: 78 Maynard Street 03/06/202C Prepared By: Outdoor Unit Parameters: Unit Model- 24ANB Unit Size- 3 Tons(Size 36) Variations: Standard Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 53.0 59.0 64.5 64.5 61.5 59.5 52.5 A-Weighted Sound Power,dBA 70.0 Indoor Coil Parameters: Unit Model: CNPV Unit Size: 3 Tons(Size 36) Cabinet Finish: Painted Cabinet Width: 17 inch No Indoor sound data available. The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29n Page 7 of 13