Loading...
30 Septic Inspection Reportt5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 1 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When filling out forms on the computer, use only the tab key to move your cursor - do not use the return key. A. Inspector Information Alan Weiss Name of Inspector Cold Spring Environmental Consultants, Inc. Company Name 350 Old Enfield Road Company Address Belchertown City/Town MA State 01007 Zip Code 413-323-5957 Telephone Number Title V System Inspector #738 License Number B. Certification I certify that:I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000);I have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1.Passes 2.Conditionally Passes 3.Needs Further Evaluation by the Local Approving Authority 4.Fails Inspector’s Signature 9/30/2020 Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP) within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 2 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: The septic system at a single family residence and home business (hair salon) was inspected and no evidence of failure was found. System consists of one 1,500 gallon septic tank connected to a three of distribution boxes and two 20' x 35' leachfields. Liquid levels in the septic tank and distribution boxes were at the outlet inverts with no high staining. The 1,500 gallon septic tank and the distribution boxes were in good condition. Use of a 4th bedroom as a hair salon must not be continued. 2) System Conditionally Passes: One or more system components as described in the “Conditional Pass” section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for “yes”, “no” or “not determined” (Y, N, ND) for the following statements. If “not determined,” please explain. The septic tank is metal and over 20 years old*or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. Y N ND (Explain below): t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 3 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if (with approval of Board of Health): broken pipe(s) are replaced Y N ND (Explain below): obstruction is removed Y N ND (Explain below): distribution box is leveled or replaced Y N ND (Explain below): The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if (with approval of the Board of Health): broken pipe(s) are replaced Y N ND (Explain below): obstruction is removed Y N ND (Explain below): 3)Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b) that the system is not functioning in a manner which will protect public health, safety and the environment: t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 4 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection C. Inspection Summary (cont.) Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate “Yes” or “No” to each of the following for all inspections: Yes No Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 5 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool Liquid depth in cesspool is less than 6” below invert or available volume is less than ½ day flow Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: . Any portion of the SAS, cesspool or privy is below high ground water elevation. Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. Any portion of a cesspool or privy is within 50 feet of a private water supply well. Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis.[This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. The system fails.I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems:To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either “yes” or “no” to each of the following, in addition to the questions in Section C.4. Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area – IWPA) or a mapped Zone II of a public water supply well t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 6 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection C. Inspection Summary (cont.) If you have answered “yes” to any question in Section C.5 the system is considered a significant threat, or answered “yes” to any question in Section C.4 above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section C.4 shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6.You must indicate “yes” or “no” for each of the following for all inspections: Yes No Pumping information was provided by the owner, occupant, or Board of Health Were any of the system components pumped out in the previous two weeks? Has the system received normal flows in the previous two week period? Have large volumes of water been introduced to the system recently or as part of this inspection? Were as built plans of the system obtained and examined? (If they were not available note as N/A) Was the facility or dwelling inspected for signs of sewage back up? Was the site inspected for signs of break out? Were all system components, excluding the SAS, located on site? Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? Was the facility owner (and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS)on the site has been determined based on: Existing information. For example, a plan at the Board of Health. Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 7 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information 1.Residential Flow Conditions: Number of bedrooms (design):3 Plus 150%Number of bedrooms (actual):4 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x # of bedrooms):495+ Description: System consists of a 1,500 gallon septic tank, three distribution boxes and two leachfields uniquely constructed in series. The existing garbage disposal was removed to acccomodate a 4 bedroom design. Use of a fourth bedroom as a hair salon must be discontinued (not allowed on a septic system). Number of current residents:2 Does residence have a garbage grinder?Yes No Does residence have a water treatment unit?Yes No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection information in this report.)Yes No Laundry system inspected?Yes No Seasonal use?Yes No Water meter readings, if available (last 2 years usage (gpd)): Detail: Garbage disposal was removed and must remain removed. Condensate tubing must be removed from the septic system. Sump pump?Yes No Last date of occupancy:Current Date t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 8 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 2.Commercial/Industrial Flow Conditions: Type of Establishment: Design flow (based on 310 CMR 15.203):Gallons per day (gpd) Basis of design flow (seats/persons/sq.ft., etc.): Grease trap present?Yes No Water treatment unit present?Yes No If yes, discharges to: Industrial waste holding tank present?Yes No Non-sanitary waste discharged to the Title 5 system?Yes No Water meter readings, if available: Last date of occupancy/use:Date Other (describe below): 3.Pumping Records: Source of information:Owner: Not Pumped for several years. Was system pumped as part of the inspection?Yes No If yes, volume pumped:1,500 gallons How was quantity pumped determined?Measured Reason for pumping:Inspection t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 9 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 4.Type of System: Septic tank, distribution box, soil absorption system Single cesspool Overflow cesspool Privy Shared system (yes or no) (if yes, attach previous inspection records, if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract (to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract Tight tank. Attach a copy of the DEP approval. Other (describe): Approximate age of all components, date installed (if known) and source of information: Septic system is approximately 22 years old based on BOH records. Were sewage odors detected when arriving at the site?Yes No 5.Building Sewer (locate on site plan): Depth below grade:1.0 feet Material of construction: cast iron 40 PVC other (explain): Distance from private water supply well or suction line:feet Comments (on condition of joints, venting, evidence of leakage, etc.): Building sewer was in good condition with no evidence of leakage. t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 10 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 6.Septic Tank (locate on site plan): Depth below grade:0.75 feet Material of construction: concrete metal fiberglass polyethylene other (explain) If tank is metal, list age:years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate)Yes No Dimensions:10.5' x 5.5' x 5.3' Sludge depth:6" Distance from top of sludge to bottom of outlet tee or baffle 30" Scum thickness 3" Distance from top of scum to top of outlet tee or baffle 6" Distance from bottom of scum to bottom of outlet tee or baffle 9" How were dimensions determined?Measured Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Concrete 1,500 gallon septic tank was in good condition with no evidence of leakage. Liquid level was at the outlet invert with no evidence of high staining. PVC tees were in place and functioning as designed. t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 11 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 7.Grease Trap (locate on site plan): Depth below grade:feet Material of construction: concrete metal fiberglass polyethylene other (explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping:Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8.Tight or Holding Tank (tank must be pumped at time of inspection)(locate on site plan): Depth below grade: Material of construction: concrete metal fiberglass polyethylene other (explain): Dimensions: Capacity:gallons Design Flow:gallons per day t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 12 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 8.Tight or Holding Tank (cont.) Alarm present:Yes No Alarm level:Alarm in working order:Yes No Date of last pumping:Date Comments (condition of alarm and float switches, etc.): * Attach copy of current pumping contract (required). Is copy attached?Yes No 9.Distribution Box (if present must be opened)(locate on site plan): Depth of liquid level above outlet invert @ Outlet Inverts Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Distribution boxes #1 and #3 were inspected and found to be level with equal flow to the outlets. No solids carryover or leakage was observed.Liquid levels were at the outlet inverts with no evidence of high staining. t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 13 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 10.Pump Chamber (locate on site plan): Pumps in working order:Yes No* Alarms in working order:Yes No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): * If pumps or alarms are not in working order, system is a conditional pass. 11.Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: leaching pits number: leaching chambers number: leaching galleries number: leaching trenches number, length: leaching fields number, dimensions:2: 20'L x 35'W overflow cesspool number: innovative/alternative system Type/name of technology: t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 14 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 11.Soil Absorption System (SAS) (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): No evidence of hydraulic failure, ponding or damp soil conditions was observed. 12.Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth – top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow Yes No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 15 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 13.Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 16 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 14.Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: hand-sketch in the area below drawing attached separately t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 17 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection D. System Information (cont.) 15.Site Exam: Check Slope Surface water Check cellar Shallow wells Estimated depth to high ground water:4'+ feet Please indicate all methods used to determine the high ground water elevation: Obtained from system design plans on record If checked, date of design plan reviewed:1998 Date Observed site (abutting property/observation hole within 150 feet of SAS) Checked with local Board of Health - explain: 1998 Records Attached: COC from 1998 Repair Adding Second Leachfield Checked with local excavators, installers - (attach documentation) Accessed USGS database - explain: You must describe how you established the high ground water elevation: Based on topography, observed setting and BOH records. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 18 of 18 Owner information is required for every page. Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Hawthorne Terrace Property Address Steven and Jennifer Samolewicz Owner’s Name Florence City/Town MA State 01062 Zip Code 9/30/2020 Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: A. Inspector Information: Complete all fields in this section. B. Certification: Signed & Dated and 1, 2, 3, or 4 checked C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist) completed D. System Information: For 8: Tight/Holding Tank – Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included 30' 48' 25.7' 36' 29.5' 42' at TIfIS 1,$' 10 CERTIFY, S-1/715/ 9y A • nolL. Alma accordance / with a f the provisions The issuance of this certifica Certificate expir on DATE of be construed as a guarantee that the system will function as designed. This e shall / 0-0-G Inspector Ay, THE COMMONWEALT OF MASSACHUSETTS MASSACHUSETTS Certifi E t Contiatinnr.e t the On-site Sewage Disposal System installed ( ) or repaired/gplaced ( on / 5 1464:2 EXCLVfor 2S-iev e J.e 5-71.A4.4 o few r e r- ha beer}, onstructed in of Title 5 and the for Disposal System Construction Permit No /0° 1 dated Use of this system is conditioned on compliance with the provisions set forth below: )INV1 011d3S NO11VO 0-MT :038111038 3ZIS >INV1 038111038 SNOTIVO Ugg = %ON x AVO/831VM31SVM JO SNO11V0 1VSOdS10 30V88V0 H1IM NOISY] >INV1 3LLd3S 'ONO-I ,5£ x 30IM r-0Z I'LJ '05IO7fir NOIS30 V38V 033I4 H3V31 038111038 01313 AO 564 = 1. X 01313 JO is OC£ :1VSOdS10 30V98V0 HlIM = 038111038 ONIHOV31 V38V = '3'S/0d0 31V8 ONIOV01 AVV-IVO OTT. MMA A1IVO NOIS3C V38V ONIHOV31 S 31111 '3000 INOdIAN3 I1Y1S 3ONVOK00V NI SVM >NOM 11V 3NO1S 03HSVM :/t L 01 .*4/2 3NOIS Cl3HSVM -.4/1. 01 .9/1. (*NIN) HSINLA ZZ ON(1080 ONI1SIX3 diNnS '13A31 13S X08 N011ne181SIG (silos SSV10) V38V vio_uoe Js/-ivo = V38V 11vm3als Jstivo _ = HONI/"NINI :JO 31Y8 NOI1V-10083d V 210J V38V HOV31 JO 133J 38V(10S/831VM31SVM JO NOTIVO NI/NIN1 z> •31V8 NO11V10083d = AVO/NOS83d/831VM31SVM JO SNOTIVO gg x SNOS2:13d SNOS83d 9 = 11008038/SNOS83d Z x SIA1008039 31V8 ONICV01 1N3MJJ3 78 MO-Li NOIS30 A-11V0 '0310N 383HM 1d33X3 'S3ONV83101 318V1d333V NIHIIM 38 01 038V3ddV S30V80 ONV S183ANI NO1103dSNI ONI8110 '6 .30NYN31NIVIN 3N11110e1 ONV ONIdiNfld 0131SAS 'SN131SAS JO 3ONVN31NIVNI ONV NOIIO3dSNI lavdens 'g 31111 83d SV SISV8 8V1f1038 V NO 03NV310 ONV 03103dSNI 38 ainoHs >INV1 011d3S 3H1 'N01101181SNO0 a()J S30V80 ONV ino,kvi JO 1N3N1HSI -18V1S3 3H1 01 3AI1V138 1081N00 1V01183A ONV 1V1NOZI80H 803 318ISNOdS38 SVM 8010V81N00 3H1 't 'S1V1831VNI 0313103dSNII JO Nouvznun ONV NOI1V11V1SNI 3H1 803 1.111181SNOdS38 ON S3>iV1 S3IVIOOSSV A3111CH '0313103dS SV '3dId G31V80J83d OAd „.fr 39 11VHS S3N11 Nounelaisia 3H1 'S1V1831V1A4 0313103dSM1 83H10 JO Nouvznun ONV NOI1V11V1SNI 3H1 803 A111181SNOdS38 ON S3)IV1 S3IVIOOSSV A311NnH '03IJ103dS SV '3dId OAd «4 38 11VHS ONIdld 830V3H ONV X08 Nounefaisia 3H1 01 '>iNV1 011d3S 3H1 01 3SCIOH 3H1 11083 ONIdId 83M3S 11V 'S *SNYld 3S3H1 NO 03101d30 ION 53111111) 803 A111181SNOdS38 ON S3>IV1 S3IVIOOSSV A311NIIH '31IS 3H1 1V s311nun G3S0dO8d 80 ONIISIX3 11V 101d30 ION AVNI SNVId 3S3H1 'SNO1133dSNI 03N011N3W 3A08V 3H1 0NI8110 03A83S80N11 ONV 8010V81N00 391 A9 03znan S381103008d ao SNO110V 804 A11118ISNOdS38 ON S3NV1 S3IVIOOSSV A311N11H 'N01101181SNO0 JO S3SVHd 31V ONI8110 31IS NO ION 383M S3AI1V1N3S38d38 ,S3IVIOOSSV A311NCIH 1VH1 10V3 31-11 01 3n0 •IAGISAS 3H1 JO NO11310'100 ONV 011183A00 3H1 01 8018d NO1103dSNI 1VNIJ V 803 OS -1V ONV 01313HOV31 31-11 JO NOI1V11V1SNI 31-11 01 8018d 1N31SAS 3H1 JO 1101108 3H1 ONV 1114 3H1 103dSN1 01 1N3S38d 383M S3A11V1N3S38d321 ,S3IVIOOSSV A311NIIH •NOLV1IV1SNI 01 8018d 1VA08ddV 2103 NOLVOIJI1ON N31118M 1f10H11M SNWId NOIS30 3H1 NI 0313103dS ION S1V1831VIN JO Nouvznun 80 SNO11/2011V S,8013V81N00 V 803 A11118ISNOdS38 ON S3>iV1 S3IVIOOSSV A311N11H 7 'S3N1-1 A1213d08d JO NOI1VNI1183130 391 803 030N3INI ION 38V ONV NOIS30 01\11833NION3 V JO rinsa 3H1 38v SNV1d 3S3H1 NO 03101d3C1 SNOLLION00 3H1 sawn, 0:10038 CSC 9 S£'A6Y - 121 HYVO HSY /. alON 33S / 3dId 3Ad (L) tr/.3,61/T = 'A313 21213H3 'S3 d Id 0131.11-I0V31 ONUS IX3 OIOdINV IN 3A1NO 3NOIS 8118HS 3dI 2131VM ON11080 HONI/NIVI 68 L 31Ve1 083d £*< NaLVM aNnoao H3NI/N111 L L 31V8 383d .£* (A321o) a NVS 'TA — 3 .9£ .9£ 111S/ONVS 'TA — 8 .0Z .0Z ONVS .U.1IS 'TA — dV .Z L .Z1 ONUS 3NLA A83A „ L 3INV00 ON11080 8 aNnoao NOM (A3ao) aNvs 3NIJ — 3 LIIS AONVS — 8 OINV0210 111S AONVS 'J'A — dV CINVS 3NIJ A2i3A 3INV080 861? NOI1VA313 # TIOH 1531 Z.96* NOI1VA313 1,# 3 -10H 1S11 :31VOS '183A )9 'ZI8OH 11A Oeld 043-0 06t, 01.4 r" x >.(' 0 = Xm < Z z z -13 Z- m z 0 -0 0 0 II 7 n 'ONIOV80 1VNIA 803 SN01101181SNI 1VI33dS 803 H- 5" > '4" 4.0 -I('' t, r-fl 83NM0 HIIM nnsNoo (Di SVM 8010V81N00 -VON NVH1 83H10 S too co w co zj cn —I . S V3 8 V 038an1sra Tiv 033S ONV INVOl 01 SVM 8010V8INO0 .4 • 0 4,..>. II b > Co r- co ..1 •NOIIICINOO 1VNIO180 Sll 01 030Y1d38 38 01 SVM inoNani. ,.,.. . ..0 ONV 1,VM3A180 '0131JHOV-31 ONIISIX3 3H1 01 3ONV881-11S10 ANY 'V z P ( 0, ,.) Eu, o i :‹m IQ; c 'SNO1103NNO0 0381(1038 3H1 ONINVIN IIIHM 0131AH0V31 ONIISIX3 *--... 4, 1:1 K 0 —4 r 0 TI m ?Hi NI )180M 31-11 NI 38V3 350 01 SVM 8010V81N00 3H1 IN31SAS c 0 o --I ONIN0110N11J V 38 11115 11IM 01313HOVII 1VNI0180 31-11 3ONIS 'T --I II z> '81Vc138 3HI NO >180M ONION3IAINI00 i+ 4. 380338 13131AH0V31 ONIISIX3 3H1 ON108VH081-1S IN31-11JA3 ONV Ln )iNV1 011d3S ONIISIX3 31-11 ino drifld 01 SVM 8010V81N00 'Z to N C...1 . 0 NIT A SNOLLVA313 3H1 NO 03SV8 (n NOI1VA313 183AN1 3H1 NO C131V01038d 383M SNOI1VA313 1131SAS ' 1. 0131AHOV31 1VNI0180 3H1 NI S3dId Nounalaisia 30 ON3 3H1 IV c m m :S310N 1VN011100V 0 ANV1 011d3S NOTIVO0-1:-T :038111038 3ZIS NNV1 038111038 SNO11VO 00 = %00Z X Ava/a31vm31svm JO SNO-11V0 079T MANIFOLD LEACHFIELD PIPES / INV. = ±494.74 to co 1VSOdSla 30V88VD HIIM NOIS30 NNVI 011d3S 'ONO-1 ,99 x 301M ,OZ OOL NOIS30 V38V 013I3 HDV31 038111038 01313 JO 'A'S 4617 = I X 013I3 AO .A.S 099 :-IVSOdSla 30V98VO HIM 'A'S 09'9 038111038 ONIHOV31 V38V = '3'S/Od0 OT 31V8 ONIOV01 AVO/.1VO or MO1A ).-11V0 1V101 NOIC3C V38V ,SNIHOV31 - ssvio) V38V IN01108 JS/1V0 V38V TIVM301S 3S/1V0 - = ▪ HON1rNIN :JO 31V8 NOI1V10083d V 80J V38V HOV31 JO 133J 38V110S/831VM3ISVM JO NO11V° NI/1\1111 z> •31V8 NOI1V10083d 029 = MO/NOS83d/831VM3ISVM AO SNOTIVO 49 X SNOS83d g SNOS83d g = W008038/SNOS83d Z X SW00803E1 ONIHOV3-1 X —X NO1103S 31111 '2000 1V1N3ViN081AN3 31V19 3H1 H1IM 3ONV08000V NI 3N00 38 01 SVM >180M 11V 9 3JA3 'MN •9 3NOIS 031-14VM _fT) 'XVII .9 (Th, ./• —112 01 .*/£ 31Y21 ONICIVO1 IN3r11143 7i MOld NOIS30 .VIVO