Loading...
Sinclair-PlansetRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTEDIN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ REQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT NORTH DRIVEWAY ℄WESTHAMPTON RD ⅊ ⅊ ⅊ ⅊ N/A VB 10.800 KW PV-001 COVER SHEET Sinclair, Rodney Steven Silverman 2015 National Grid 2015 82007111 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 Town Of Northampton Info@valleysolar.solar 50507Civil(202) 874-3483swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook DrAlpine, UT 84004 Sinclair, Rodney147 Westhampton Rd, Northampton, MA 01062 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/ BATTERY STORAGE 340 Riverside DrValley Solar Florence, MA 01062 REC REC360AA GENERAC PWRcell 7.6 APKE00014 SnapNrack Ultra Rail UR-40 Snapnrack 242-01220 L FootINTEGRATED IN INV & OPT Generac PWRcell 17 30 1 N/A 92 N/A 10 (E) GPS LOCATION:42.3015332, -72.68026669999999 9.904 KW 5 120/240V - 1 22.6°,26.6° 194° ROOF COVERING MAX ARRAY HGT. 117 N/AComp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS 200A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS GENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONSAREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. RA RA NORTH SECTION 1 SECTION 2 DRIVEWAY PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE:1/8” = 1’0” @ SHEET SIZE A3 1380SECTION 1 452 40.94% 194 22.6°SECTION-1 194 26.6°SECTION-2 113SECTION 2 QTY 30 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS*EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP B. ANCHOR SPACING SHOWNIN DETAIL. UNLESS NOTED OTHERWISE PER RACKINGMANUFACTURER CERTIFIED ENGINEERED PRODUCT ANDLOCAL REQUIREMENTS. SEE"TABLE OF DIMENSIONS" EACH SECTION DETAILED FORHORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENTMANUFACTURERS. ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL NORTH 34'-1"12'-834"9'-10"9'-8"Pre-Eng Roof Trusses 2"x4" @ 16" MAX OC Rafter-Simple Attic 16" O.C. SCALE:1/8” = 1’0”@ SHEET SIZE A3 Rafter-Simple Attic & Trusses 16" O.C. 2"x6" @ 16" MAX OC Comp Shingle 3.17 PSF QTY 30 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 6:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLYDESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAILMANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPANMAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 (E) RAFTER@ 16" O.C. TYPICAL 1'-4"TYP 4'-0"MAX SIMPLE ATTIC / RAFTER - PORTRAIT SIMPLE ATTIC / RAFTER - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL Ultra Rail UR-40 242-01220 L Foot L-Foot Flashing 6" 22.6° 3" - 6" TYP 10" 20" 20.25" 7 1/4" 6" 13'-0" 6" 22.6° 3" - 6" TYP 16.94" 33.88" 34.12" 7 1/4" 6" 13'-0" 25' Comp Shingle NOT USED 13'-0"13'-0"S-200Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGS5/16”-18 X 2-1/4” SS HCS BOLT 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURERRAIL SPLICE KITSEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE.SEE SHEET "S-100" FOR:HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMINGTYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DCAND/OR 1/3CANT.MAX COMPONENT +2" FROM SIDEOF MODULE 2" ROOF TOPCONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONS TO MEETWEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE** RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERSARE CUT OR NOTCHED * SEE DETAILS "1-2/S200" TABLE OF DIMENSIONS HOLES ALLOWED ONLY IN MIDDLE HALF OF FRAMING SPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRDOF FRAMING DEPTH, *R2, AND NO LARGERTHAN *R2/4 IN DIAMETER. MINIMUMSPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOTTO EXCEED FRAMING LENGTHIN FEET DIVIDED BY 20 NOTCHES DEEPER THAN 1/4"NOT ALLOWED ALONG TOP ORBOTTOM EDGE OF FRAMING NOTE: WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF,VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURALDECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RIDGELENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNATTACHMENT DETAILS ADDRESS kW PHOTOVOLTAIC PLANSSHEET NOTES PV RACKING LEGEND TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP 2SCALE: NTS 3 4 A.THESE NOTES APPLY TO PRE-ENGINEERED PLATED TRUSSES. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLYDESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL HAVE NO MORE THAN TWO LAYERS. (SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PV MODULE HGT. ABOVE ROOF RISE ROOF PITCH OH1 OVERHANG IN THIS AREA UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PV MODULE HGT. ABOVE ROOF RISE ROOF PITCH OH1 OVERHANG IN THIS AREA UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPAN MAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL 1 5 6 7 RISE 12 PRE-ENGINEEREDFRAMING @APPROX. 24" O.C. 2 OH1 PV 1 D1H1 D3 D2 D2 * IF BLOCKING REQUIRED32 S-201 1 S-201 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. D3 12RISE 5 6 8 1 7 3 PV 1 D1H1 OH1 D2 D1 D3 D2 * IF BLOCKING REQUIRED32 S-201 1 S-201 D224" MINWHEN NOTSTAGGERED. TYP PRE-ENGINEEREDFRAMING @APPROX. 24" O.C. ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. 15' Comp Shingle MANUF TRUSS / TRUSS - PORTRAIT MANUF TRUSS / TRUSS - LANDSCAPE NOT USED 26.6°3" - 6" TYP 16.94" 33.88" 33.88" Ultra Rail UR-40 242-01220 L Foot Integrated Unirac Flashing 26.6°3" - 6" TYP 10" 20" 19.75" NOT USED ENGINEERED TRUSS ENGINEERED TRUSS NOT USED 1 S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMPCOEFFICIENT[-0.#%/C] * 100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPEN CIRCUITVOLTAGE -=*=+*=EQUIP. CALCULATIONSPV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC DC/DC OPTIMIZER (IF APPL.) MANUFACTURER MODEL NUMBER WEIGHT Ibs RATED OUTPUT isc AMPS MAX OUTPUT VOLTAGE VOLTS MAX INPUT VOLTAGE Voc VOLTS DC COMBINER / DISCONNECT #1 MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENTDC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS STRING INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) ADDRESSTHICK WATTSMAX. AC APPARENT POWER kW PHOTOVOLTAIC PLANSDC COMBINER / DISCONNECT #2 (IF APPL.) MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENTDC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS AMPS MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT QTY MAX PV MODULE Voc MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS VOLTS DC VOLTS DC MAX INPUT FUSE/BREAKER RATING DC COMBINER / DISCONNECT #3 (IF APPL.) QUANTITY STRING INVERTER #2 SPECIFICATIONS (IF APPL.) AMPS - MAX MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECTAC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT WATTSMAX. AC APPARENT POWER QUANTITY INVERTER(S) INVERTER(S) AC COMBINER #1 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 AMPS (Imax) AMPS (Imax) AC COMBINER #2 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AMPS (Imax) AMPS (Imax) AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS AMPS (Imax) MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 ALT. ENERGY BACKFEED BREAKER (IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS BATTERY#1SPECIFICATIONS Years/MWh10/7.56Modulesion - Warranty:Li Years10:ElectronicsWarranty UL9540,UL1973,UL1642 CSA-22.2Compliance -™EbusDCNanogridRCommunicationProtocol (kg)b,l(202)445,eight(Installed)W (kg)b,l(52)15,1eight(Enclosure)W (kg)b,l55,(25)ionmodule) - Weight(Li VDC46.8ModuleVoltage -6BatteryModules (mm)n,Ix22x10(1725x560x235)68Dimensions mt,f(3000)9834,MaximumInstallationAltitude C)ᵒF,(ᵒ)30 - 86,(13 - 54RecommendedTemp.Range C)ᵒ,(Fᵒ45)-(5113,-41ngeOperatingTemp.Ra %96.5TripEfficiency-Round VDC420-360EbusVoltage:Input/OutputR kW10utesPower:2min kW8.4Power:60minutes kW6.7Power:RatedContinuous kWh17.1UsableEnergy sUnitSpecification - REC EatonDG222URB1REC360AA4367.75 x 40 x 1.18 NON-FUSIBLE DISCONNECT120/24036043.936.710.49 60 48.73 9.82 3R2 N/A 32-0.2420.0 GeneracPV Link APKE000107.38420420 GENERACPWRcell 7.6 APKE00014 760062.7 420360420202YESNO 24076004032 -20 25 -45 -0.24%0.11 1 1.11 43.9 48.73 1 E-001EXISTING120/240V Single Phase200200 04040 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=< DC2 XXX=XX=< DC3 XXX=XX=< DC4 XXX=XX=< DC5 XXX=XX=< AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X =WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3.4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BEUSED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. WHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED. WIRE COLOR CODING (2020) CEC/NEC SECTIONS 250.119 & 200.6 PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S).TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES APN ADDRESS kW PHOTOVOLTAIC PLANSAC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < DC6 XXX=XX =< DC7 XXX=XX =< DC8 XXX=XX =< #OFCOMBINEDPARALLELSTRINGS DESTINATION QTY INPARALLEL &MATERIAL QTY INPARALLEL &MATERIAL lsc (AMPS)ORCOMPONENT(AMPS) MAX INV. OUTPUTCURRENT (AMPS)ORCOMPONENT(AMPS) PV MODULE DC/DC CONVERTER (1) CU 90 #12 AWG 30 10.49 1 1.25 1.25 16.39 ROOFTOP 35 0.5" – 3.5"22 57 0.71 2 N/A 30 0.71 1.0 21.3 16.39 21.3 E-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT(1) CU 90 #10 AWG 40 8 1 1 1.25 10 ROOFTOP 32 0.5" – 3.5"22 54 0.76 10 N/A 40 0.76 1.0 30.4 10 30.4PV LINK Y-CONNECTOR Y-CONNECTOR JUNCTION BOX JUNCTION BOX INVERTER BATTERY INVERTER (1) CU 90 #10 AWG 40 8 3 1 1.25 30 ROOFTOP 32 0.5" – 3.5"22 54 0.76 4 N/A 40 0.76 1.0 30.4 30 30.4 (1) CU 90 #10 AWG 40 24 1 1 1.25 30 ATTIC 32 IN ATTIC 0 32 0.96 4 0.80 40 0.96 0.80 30.72 30 30.72 (1) CU 90 #10 AWG 40 27.77 1 1 1.25 34.71 EXT WALL 32 N/A 0 32 0.96 2 1.0 40 0.96 1.0 38.4 34.71 38.4 AUTO TRANSFER SWITCH INVERTER AC DISCONNECT AC DISCONNECT PRODUCTION METER PRODUCTION METER EXISTING SERVICE PANEL INVERTER AUTO TRANSFER SWITCH EXISTING UTILITY METER 47.0 0.94 0.94 0.94 0 0 0 N/A N/A N/A N/A 0 0.94 40.0 50.0 47.0 61.1 1.0 1.0 0.94 0.94651.033232INT/EXT WALL5050 (1) CU INT/EXT WALL (1) CU 75 #8 AWG 50 1.25 32 40.0 INT/EXT WALL 32 32 3 1.0 50 0.94 1.0 47.0 40.0 (1) CU 75 #8 AWG 50 1.25 32 40.0 INT/EXT WALL 32 N/A 0 32 0.94 3 1.0 50 0.94 1.0 47.0 40.0 47.0 (1) CU 75 #8 AWG 50 1.25 32 40.0 INT/EXT WALL 32 32 3 1.0 50 47.0 (1) CU 75 #6 AWG 65 N/A 61.1 75 #3/0 AWG 200 N/A 50 50 32 32 3 1.0 200 0.94 1.0 188 50.0 188 LEGEND RELEASEREVDATE NAME ADDRESSTHREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 3 DC DISCONNECT 4 DC MODULE LEVEL RSD 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 AC/DC INVERTER W/ INTE AC DISC 9 BATTERY 10 AUTO TRANSFER SWITCH 11 PROD/GEN METER 12 SUB PANEL 13 14 15 EXISTING UTILITY METER NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED TAG APN ADDRESSSEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS kW PHOTOVOLTAIC PLANSELECTRICAL NOTES UNGROUNDED PV SYSTEMS:•INVERTERS, MODULES, AND DC COMPONENTS MUST BE LISTEDFOR USE IN UNGROUNDED SYSTEMS, TYPICALLY TRANSFORMER-LESS (TL) •OCPD'S WHERE NECESSARY MUST HAVE DISCONNECTING MEANS. •PV SOURCE CIRCUITS MUST BE EITHER PV WIRE AND LISTED FOR WET LOCATIONS OR JACKETED MULTI-CONDUCTOR CABLESINSTALLED IN RACEWAY.•THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCTOR. •REQUIRE EQUIPMENT GROUNDING BUT DOES NOT HAVE SYSTEMGROUNDING; NO DC CURRENT-CARRYING CONDUCTOR ISCONNECTED TO GROUND. THESE CONDUCTORS ARE COLORCODED DIFFERENTLY THAN GROUNDED PV SYSTEMS. AC/DC ELECTRICAL NOTES: •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BERATED FOR 600 VOLTS ON THE DC / PV POWER SIDEOF THE INVERTER. •EXTERIOR ENCLOSURES TO BE NEMA TYPE 3R OR BETTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE.INTERCONNECTION NOTES: •705.12(D)(4) CIRCUIT BREAKERS MUST BE SUITABLE FORBACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED,ARE SUITABLE FOR BACKFEEDING. •690.10(E) & 690.17(A) CIRCUIT BREAKERS OR MANUALLYOPERABLE DISCONNECTS MARKED "LINE" AND "LOAD" SHALL NOT BE BACK-FED.•705.12(D)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND STRING MODULE QTY INVERTER# BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 DC2 DC3 DC4 DC5 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE CONDUIT TABLE AC6 AC7 AC8 AC9 AC10 DC6 DC7 DC8 16 AC DISCONNECT (INDEPENDENT) • * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS 1 1 1 1 1 1 1 1 1 1 DC1 DC1 DC1 DC1 DC1 G G EGC DC3 DC4 5 6 MODULES 6 MODULES 6 MODULES 6 MODULES 6 MODULES MODULE NAMEPLATERATING 360WMC-4Y-CONNECTORS 4 4 4 4 4 4 4 4 4 4 2 2 2 2 2 DC2 GG PWRCell - + DC5 13 3 6 7 INVERTER NAMEPLATE RATING 7600W/ 240V THEBATTERYWILLONLYBECHARGEDBYPV.THEBATTERYWILLDISCHARGETOONSITELOADS. THEBATTERYDISCHARGETOTHEGRIDONLYIFREQUESTEDBYTHEGRIDVIACONNECTEDSOLUTIONS. AC N G L2 L1DC GNL2L1 GNL2L1 N G L2 L1 AUTO TRANSFER SWITCH L1 L2 N L1 L2 N G L1L2 N 10 AC4 50AAC5 AC5 EMERGENCYRSD SWITCH AC1 AC3AC2 N G L2 L1PV N G L2 L1 11 L2 L1 L2 L1 GG NN 9 G N BUSRATING200A 15 MAIN C/BRATING200A GEC M 16 EGC 40A LOCATED EXTERIORSOLAR GENERATION (LOAD) BOTTOM LUGS TO TOP LUGS TO UTILITY (LINE) NATIONAL GENERATION METERREADILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT(UTILITY ONLY) VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEARMETER NEMA 3R EMERGENCY BATTERYDISCONNECT 30 REC REC360AA 5 PV Link APKE00010 N/A INTEGRATED IN INV 30 SnapRS Device 2 Soladeck RSTC 0799-5B N/A INTEGRATED IN INV & OPT 1 GENERAC PWRcell 7.6 APKE00014 0 1 6 Eaton DG222URB INV 1 RSXW200A3 2 6 INV 1 3 6 INV 1 4 6 INV 1 1 1 1 0 0 5 6 INV 1 1 1 120/240V - 1 40A 1 NEW MAIN SERVICE PANEL Generac PWRcell 17 Battery EXISTING MAIN SERVICE PANEL 200A BUS/200A MB NATIONAL SMART GEN METER NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(B)(2)(3)(b)E-003DC/DC OPTIMIZER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT2 #12 AWG PV Wire #6 AWG N/A Open Air 11 #10 AWG PV Wire #6 AWG N/A Open Air 5 #10 AWG PV Wire #8 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 2 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #6 AWG THWN-2 #8 AWG 3/4 inch EMT 3 #3/0 AWG THWN-2 #4 AWG 1-1/2 inch EMT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND AC DISCONNECT DC DISCONNECT DC COMBINER BOX AUTO TRANSFER SWITCHCB DC AC ATS ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC(EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBSARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKINGSPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2. FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TOBOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER.THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSSOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATTINV#DC/AC STRING INVERTER CLP CRITICAL LOADS PANEL SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP PERFORMANCE METER UTILITY METER P M XFMR TRANSFORMER JUNCTION BOXJB RSD RAPID SHUTDOWN SUB-PANELSUB ES EMERGENCY RSD SWITCHEMERGENCY DISCONNECTED INV1 AC SPMPATSBATTEDES NORTH JB JB SCALE:1/8” = 1’0”@ SHEET SIZE A3QTY 30 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER E-100PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSSHEETNOTES1SCALE:1/2"=1'-0"CONDUIT,RACEWAY,J-BOX,ANDPULLBOXES 2 3 5 6 7 SCALE:1/4"=1'-0"8 9 4 1.PLACEONCONDUITAND/ORRACEWAYSEVERY10'(60"),12"FROMBENDS,12"ABOVEANDBELOWPENETRATIONS. 2.CODEREFERENCE:NEC690.31(G)(3)3.MINIMUMOF11/8"x53/4" 4.FONT:3/8"AND.8WIDTHFACTOR. 5.REFLECTIVEWHITELETTERSONAREDBACKGROUND. J-BOX,DCCOMBINER,ANDDCDISCONNECT WARNING:ELECTRICSHOCKHAZARD.THEDCCONDUCTORSOFTHISPHOTOVOLTAICSYSTEMAREUNGROUNDEDANDMAYBEENERGIZED SCALE:1/4"=1'-0" 1.ONLYFORUNGROUNDEDSYSTEMS. 2.PLACEDONALLENCLOSURESWITHUNGROUNDEDCIRCUITSORDEVICESWHICHAREENERGIZEDANDMAYBEEXPOSEDDURINGSERVICE. 3.CODEREFERENCE:NEC690.35(F) 4.MINIMUMOF3"x101/2" 5.FONT:3/8" 6.WHITELETTERSONAREDBACKGROUND. NON-LOADBREAKDCCOMBINER/J-BOX WARNING:ELECTRICSHOCKHAZARDDONOTTOUCHTERMINALSTERMINALSONBOTHLINEANDLOADSIDESMAYBEENERGIZEDINTHEOPENPOSITION SCALE:1/2"=1'-0" 1.PLACEDONDCDISCONNECT(S)ANDONANYEQUIPMENTTHATSTAYSENERGIZEDINTHEOFFPOSITIONFROMTHEPVSUPPLY. 2.CODEREFERENCE:NEC690.17(E) 3.MINIMUMOF31/2"x10" 4.FONT:3/8" 5.WHITELETTERSONAREDBACKGROUND. INVERTER(S)SCALE:1/2"=1'-0" WARNING:ELECTRICSHOCKHAZARDIFAGROUNDFAULTISINDICATED,NORMALLYGROUNDEDCONDUCTORSMAYBEUNGROUNDEDANDENERGIZED 1.NORMALLYALREADYPRESENTONLISTEDINVERTERS 2.CODEREFERENCE:NEC690.5(C) 3.MINIMUMOF31/2"x101/2" 4.FONT:3/8" 5.WHITELETTERSONAREDBACKGROUND. ACANDDCDISCONNECTS PHOTOVOLTAICSYSTEMDISCONNECT 1.PLACEONALLACANDDCDISCONNECTS 2.CODEREFERENCE:NEC690.14(C)(2) 3.MINIMUMOF1"x101/2" 4.FONT:3/8" 5.WHITELETTERSONAREDBACKGROUND. SCALE:1/4"=1'-0"SCALE:1/4"=1'-0" DCCOMBINERBOX 1.CODEREFERENCE:NEC690.16(B)ANDNEC690.17 2.USEPLACARD"COMBINER#1"WHENMORETHAN1DCCOMBINERISUSED.NUMBERACCORDINGTOTHREELINEDIAGRAMANDCALCULATIONS. 3.MINIMUMOF1"x4" 4.FONT:3/8"AND.75TO.8WIDTHFACTOR 5.WHITELETTERSONAREDBACKGROUND. 1.CODEREFERENCE:NEC690.16(B) 2.USEONNON-LOADBREAKRATEDDISCONNECTION. 3.MINIMUMOF1"x6" 4.FONT:3/8"AND.8WIDTHFACTOR 5.WHITELETTERSONAREDBACKGROUND. DCDISCONNECTS 1.USEPLACARDONCUSTOMERGENERATIONMETER. 2.VERIFYWHICHPLACARDISREQUIREDWITHAHJ. 3.MINIMUMOF1"x4" 4.FONT:3/8"AND.8WIDTHFACTOR 5.WHITELETTERSONAREDBACKGROUND. SOLARkWhMETER SCALE:1/2"=1'-0" INVERTER#1 1.USEPLACARD"INVERTER#1"WHENMORETHAN1INVERTERISUSED.NUMBERACCORDINGTOTHREELINEDIAGRAMANDCALCULATIONS. 2.MINIMUMOF1"x4" 3.FONT:3/8" 4.WHITELETTERSONAREDBACKGROUND. SCALE:1/2"=1'-0"INVERTER'S USEPLACARD"[AC][DC]DISCONNECT#1"WHENMORETHANONEDISCONNECTISUSED.NUMBERACCORDINGTOTHREELINEDIAGRAMANDCALCULATIONS. 10 SCALE:1/4"=1'-0"MAINSERVICEPANEL 1.COMBINATIONPLACARDSMAYBEUSEDINPLACEOFMULTIPLEPLACARDSFORTHESAMEDEVICE.ALLINFORMATIONFROMTHEMULTIPLEPLACARDSMUSTBEPRESENT. 2.BLACKLETTERSWITHYELLOWBACKGROUNDMAYBEUSEDINPLACEOFTHESTANDARDWHITELETTERSWITHREDBACKGROUNDWITHAHJAPPROVAL. 3.ALLINTERIORANDEXTERIORDCCONDUIT,ENCLOSURES,RACEWAYS,CABLEASSEMBLIES,JUNCTIONBOXES,COMBINERBOXESANDDISCONNECTSAREMARKED.(IFC605.11.1,NEC690.31[E][3],NEC690.31[E][4],690.17&690.53) 4.THEMARKINGSONTHECONDUITS,RACEWAYSANDCABLEASSEMBLIESAREEVERY10FEET,WITHINONEFOOTOFALLTURNSORBENDSANDWITHINONEFOOTABOVEANDBELOWALLPENETRATIONSOFROOF/CEILINGASSEMBLIES,WALLSANDBARRIERS.(IFC605.11.1.4,NEC690.31[E][3]&NEC690.31[E][4]) 5.WHEREPVCIRCUITSAREEMBEDDEDINBUILT-UP,LAMINATEORMEMBRANEROOFINGMATERIALSINROOFAREASNOTCOVEREDBYPVMODULESANDASSOCIATEDEQUIPMENT,THELOCATIONOFCIRCUITSSHALLBECLEARLYMARKED. 6.REQUIREDLABELSSHALLBEPERMANENTANDSUITABLEFORTHEENVIRONMENT.MATERIALSUSEDFORMARKINGMUSTBEWEATHERRESISTANT.ULSTANDARDISRECOMMENDEDTODETERMINEWEATHERRATING.ULLISTINGOFMARKINGSISNOTREQUIRED.SEEULLABELINGSYSTEM969(UL969) 7.MARKINGCONTENTANDFORMAT: 7.1.ARIALORSIMILARFONT,NON-BOLD. 7.2.MINIMUM3/8"LETTERHEIGHTFORHEADERS. 7.3.MINIMUM1/16"LETTERHEIGHTFORDATA 7.4.CONTRASTINGBACKGROUNDANDLETTERING. 7.5.ALLCAPITALLETTERS. 7.6.CONTRASTINGSPACEBETWEENROWSOFTEXT 7.7.DIMENSIONSOFPLACARDSAREAPPROXIMATE.MAYBE REDUCEDAND/ORINCREASEDTOULAPPROVEDMANUFACTUREDPRODUCT CODEABBREVIATIONS:NATIONALELECTRICALCODE(NEC)INTERNATIONALBUILDINGCODE(IBC)INTERNATIONALRESIDENTIALCODE(IRC)INTERNATIONALFIRECODE(IFC)UNDERWRITERSLABORATORY(UL) 90.5()(1)(a .3/8"BACKCHARACRSOYELLOWBACKGROUD,RAGCHARACRS.3/16"BACKOWHBACKGROUD. LATMTHA1mFROHSRVCDSCOMASTWHIHTHPVSYSTMSATASHALLIIATTHLATIALLITIIAPISHUTWSWITHSITATTHSAMLATI. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS P-001QTY 30 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES1SCALE:1/4" = 1'-0"2 3 4 SCALE:1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE:1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE PV SYSTEM DC DISCONNECT ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDC RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS SCALE:1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE:1/2" = 1'-0" CAUTION DC DISCONNECTS & DISCO. COMBINER DYNAMIC PLACARDSPV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT #1 #2 #3 RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING STRING INVERTER #1 - INTEGRATED AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS STRING INVERTER #2 - INTEGRATED AC DISCONNECT AC DISCONNECT #1 - INDEPENDENT/ SEPARATE AC SUB-PANEL #1 ADDRESS kW PHOTOVOLTAIC PLANS#1 #2 #3 VDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC 1.PRIME CONTRACTOR / PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEMINSTALLATION. PRIME CONTRACTOR / PERMITAPPLICANT SIGNER WILL BE RESPONSIBLE FORCOLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALLTHE EXTERIOR MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEM DETAILED IN THISDOCUMENT. 2.ADVANCED SOLAR SOLUTIONS, INC ISRESPONSIBLE FOR APPLYING SUPPLIEDINFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TOCONTRACT CONDITIONS BETWEEN THE CLIENTAND ADVANCED SOLAR SOLUTIONS, INC. INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES 1.PLACARDPLACEDATELECTRICALSERVICEANDATTHEPVINVERTERANDPVDISCONNECTSIFNOTATTHESAMELOCATION. 2. MAPPLACARDPROVIDESADIRECTORYOFTHESERVICEDISCONNECTINGMEANSANDPHOTOVOLTAICSYSTEMDISCONNECTIONMEANS. 3. CODEREFERENCE:NEC690.56(A)(B),705.10 4. WHITELETTERSONAREDBACKGROUND. 5. MINIMUMOF73/4"x5" 6. FONT:3/4""CAUTION",1/4""WARNING",3/16"HEADER,1/8"DATAANDNOTES 7.PLACARDWILLBEPLACEDADJACENTTOTHEMAINSERVICEDISCONNECTINALOCATIONCLEARLYVISIBLEFROMWHERETHEDISCONNECTISOPERATED.(IFC605.11.1.3) ITHCOMBINEDWARNINGPLACARDIFREQUIRED.EXAMPLE:LADWP) 1.PLACARDPLACEDATELECTRICALSERVICEANDATTHEPVINVERTERANDPVDISCONNECTSIFNOTATTHESAMELOCATION. 2.MAPPLACARDPROVIDESADIRECTORYOFTHESERVICEDISCONNECTINGMEANSANDPHOTOVOLTAICSYSTEMDISCONNECTIONMEANS. 3.CODEREFERENCE:NEC690.56(A)(B),705.10 4.WHITELETTERSONAREDBACKGROUND. 5.MINIMUMOF61/2"x61/2" 6.FONT:3/4""CAUTION",1/4"HEADER,1/8"DATAANDNOTES 7.PLACARDWILLBEPLACEDADJACENTTOTHEMAINSERVICEDISCONNECTINALOCATIONCLEARLYVISIBLEFROMWHERETHEDISCONNECTISOPERATED.(IFC605.11.1.3) 1.PLACARDPLACEDONEACHDISCONNECT,IFMORETHANONEPRESENT. 2.VALUESMUSTMATCHEQUIPMENTCALCULATIONS.SEESHEET"E-001/DCDISCONNECT[#]" 3.CODEREFERENCE:NEC690.53 4.MINIMUMOF21/2"x8"OR5"x21/2"RESPECTIVELY. 5.FONT:3/8"HEADER,3/16"DATA 6.WHITELETTERSONAREDBACKGROUND. 7.INSOMECASESTWOLABELSMAYBEREQUIRED.ANINVERTERWITHINTEGRATEDDCDISCONNECTUTILIZINGTWOMPPTTRACKERS;IFCONFIGURATIONUSESDIFFERENTMODULES. 1.PLACARDPLACEDONEACHSOLARSYSTEMDISCONNECTINGCOMPONENT. 2.VALUESMUSTMATCHEQUIPMENTCALCULATIONS.SEESHEET"E-001/ACDISCONNECT[#]" 3.CODEREFERENCE:NEC690.54 4.MINIMUMOF11/2"x81/2"OR13/4"x61/2"RESPECTIVELY. 5.FONT:3/8"HEADER,3/16"DATA 6.WHITELETTERSONAREDBACKGROUND. 1.(#1)PLACARDPLACEDATMAINUTILITYSERVICEDISCONNECT/BREAKERANDPVSYSTEMSUPPLYBREAKERATPOINTOFINTERCONNECTION.(#2&#3)PLACARD(S)REQUIREDWITH#1PLACARDWHENUTILITYSERVICEANDPVSYSTEMDISCONNECT(S)ARENOTLOCATEDNEXTTOEACHOTHER.MAPPLACARDREQUIREDASSPECIFIED. 2.VALUESMUSTMATCHEQUIPMENTCALCULATIONS. 2.1.VALUESWILLMATCHLOADCENTERORSUB-PANELVALUESIFINSTALLEDAFTERINVERTERS.IFACCONNECTIONTOSERVICEPANELCOMESFROMINVERTERS;SEESHEET"E-001/STRINGINVERTER[#]SPECIFICATIONS".2.1.1.INVERTERSAREPARALLELCONNECTIONS. 2.1.2."RATEDACOUTPUTCURRENT"WILLBETHESUMOFTHEINVERTERS 2.1.3."ACNORMALOPERATINGVOLTAGE"WILLBETHENAMEPLATERATINGOFTHEINVERTER 3.CODEREFERENCE:NEC690.54,NEC705.12(D)(3) 4.MINIMUMOF2"x61/2"(#1),VARIES(#2&#3) 5.FONT:3/8"HEADER,3/16"DATA(#1),1/4"(#2&#3) 6.WHITELETTERSONAREDBACKGROUND. 1. 2. 3. 4. COMBINATIONPLACARDSMAYBEUSEDINPLACEOFMULTIPLEPLACARDSFORTHESAMEDEVICE.ALLINFORMATIONFROMTHEMULTIPLEPLACARDSMUSTBEPRESENT. BLACKLETTERSWITHYELLOWBACKGROUNDMAYBEUSEDINPLACEOFTHESTANDARDWHITELETTERSWITHREDBACKGROUNDWITHAHJAPPROVAL. ALLINTERIORANDEXTERIORDCCONDUIT,ENCLOSURES,RACEWAYS,CABLEASSEMBLIES,JUNCTIONBOXES,COMBINERBOXESANDDISCONNECTSAREMARKED.(IFC605.11.1,NEC690.31[E][3],NEC690.31[E][4],690.17&690.53) REQUIREDLABELSSHALLBEPERMANENTANDSUITABLEFORTHEENVIRONMENT.MATERIALSUSEDFORMARKINGMUSTBEWEATHERRESISTANT.ULSTANDARDISRECOMMENDEDTODETERMINEWEATHERRATING.ULLISTINGOFMARKINGSISNOTREQUIRED.SEEULLABELINGSYSTEM969(UL969) 5.MARKINGCONTENTANDFORMAT: 5.1.ARIALORSIMILARFONT,NON-BOLD. 5.2.MINIMUM3/8"LETTERHEIGHTFORHEADERS.5.3.MINIMUM1/16"LETTERHEIGHTFORDATA5.4.CONTRASTINGBACKGROUNDANDLETTERING.5.5.ALLCAPITALLETTERS. 5.6.CONTRASTINGSPACEBETWEENROWSOFTEXT 5.7.DIMENSIONSOFPLACARDSAREAPPROXIMATE.MAYBEREDUCEDAND/ORINCREASEDTOULAPPROVEDMANUFACTUREDPRODUCT6.ANSIZ535.4-2014PRODUCTSAFETYSIGNSANDLABELS:THISINFORMATIONALNOTEANDITSREQUIREMENTSFORPLACARDSMAYBEUSEDWITHPRIORAPPROVALOFTHEAHJ.MOSTNOTABLEDIFFERENCESISCOLOROFPLACARDSANDUSEOFHANDWRITTENVALUESWITHINDUSTRIALMARKERSONSTANDARDPLACARDSWHERETHEVALUEMAYCHANGEATAFUTUREDATE.I.E.ADDINGMODULESATAFUTUREDATE,ORSTANDARDPLACARDMANUFACTURERINSTALLEDONELECTRICALCOMPONENT.AHJAPPROVALREQUIRED.(SEENOTE#1FORINDIVIDUALPLACARDS) CODEABBREVIATIONS:NATIONALELECTRICALCODE(NEC)INTERNATIONALBUILDINGCODE(IBC)INTERNATIONALRESIDENTIALCODE(IRC)INTERNATIONALFIRECODE(IFC)UNDERWRITERSLABORATORY(UL) N SOLAR ARRAYON ROOF TOP (E) UTILITY METER& SERVICE PANEL AC DISCO INVERTERW/ DC DISCO N PRODUCTION METER AUTOTRANSFER SWITCH BATTERY EMERGENCYRSD SWITCH&BATTERYDISCO. SOLAR ARRAYON ROOF TOP (E) UTILITY METER& SERVICE PANEL AC DISCO INVERTERW/ DC DISCO PRODUCTION METER AUTOTRANSFER SWITCH BATTERY EMERGENCYRSD SWITCH&BATTERYDISCO. 32.0240240 32.04040 240293293 32 240 32.0 32 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSαexperience performance 375 wp Power ELIGIBLE FOR rec Alphα black Series www.recgroup.com 28 [1.1] 1721±2.5 [67.75 ±0.1] 802 [31.5]455 [17.9]956 [37.64]1016±2.5 [40 ±0.1]17 [0.7]45 [1.5] 1000 [39] 1200 [47] 11±0.2[0.43 ±0.8]6.6±0.2 [0.26 ±0.08]20.5±0.5[0.78 ±0.08] 30 [1.18] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GR Ref: PM-DS1202Rev- D 03.20Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Measurements in mm [in] 100 200 300 400 500 600 700 800 900 1000 85 90 95 100 Irradiance (W/m²) Typical low irradiance performance of module at STC:Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:0.26 /°C Temperature coefficient of VOC:0.24 /°C Temperature coefficient of ISC:0.04 /°C *The temperature coefficients stated are linear values Operational temperature:40 ... +85°C Maximum system voltage:1000 V Design load (+): snow Maximum test load (+): 4666 Pa (97.5 lbs/sq )+ 7000 Pa (146 lbs/sq )* Design load (-): wind Maximum test load (-): 2666 Pa (55.6 lbs/sq )+ 4000 Pa (83.5 lbs/sq )* Max series fuse rating:25 A Max reverse current:25 A + Calculated using a safety factor of 1.5 * See installation manual for mounting instructions Founded in Norway in 1996, REC is a leading vertically integrated solar energy company. Through integrated manufacturing from silicon to wafers, cells, high-quality panels and extending to solar solutions, REC provides the world with a reliable source of clean energy. REC’s renowned product quality is supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with headquarters in Norway and operational headquarters in Singapore. REC employs around 2,000 people worldwide, producing 1.5 GW of solar panels annually. IEC 61215:2016, IEC 61730:2016, UL 1703, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 1703 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 612152:2016 Hailstone (35mm) AS4040.2 NCC 2016 Cyclic Wind Load ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 989898 Annual Degradation 0.250.250.25 Power in Year 25 929292 See warranty documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECxxxAA Black Power Output - PMAX (Wp) 355 360 365 370 375 Wa Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 36.4 36.7 37.1 37.4 37.8 Nominal Power Current - IMPP (A) 9.77 9.82 9.85 9.9 9.94 Open Circuit Voltage - VOC (V) 43.6 43.9 44 44.1 44.2 Short Circuit Current - ISC (A) 10.47 10.49 10.52 10.55 10.58 Power Density (W/sq )202.9 19.15 19.41 19.68 19.94 Panel Efficiency () 20.3 20.6 20.9 21.2 21.4 Power Output - PMAX (Wp)271 274 278 282 286 Nominal Power Voltage - VMPP (V) 34.3 34.6 35.0 35.2 35.6 Nominal Power Current - IMPP (A) 7.89 7.93 7.96 8.00 8.03 Open Circuit Voltage - VOC (V) 41.1 41.4 41.5 41.6 41.6 Short Circuit Current - ISC (A) 8.46 8.47 8.50 8.52 8.55 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one wa class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 /s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 120 half-cut cells with REC heterojunction cell technology 6 strings of 20 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymeric construction (black) Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PVKBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm² PV wire, 39 + 47 in (1 + 1.2 m)in accordance with EN 50618 Dimensions:67.8 x 40 x 1.2 in (1721 x 1016 x 30 mm) 18.8 sq (1.75 m²) Weight:43 lbs (19.5 kg) Origin:Made in Singapore STC NMOTREC ALPHα BLACK SERIESPRODUCT DATASHEET INVERTER CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT Generac Power Systems, Inc.S45 W29290 Hwy. 59, Waukesha, WI 53189www.Generac.com 1-888-GENERAC (1-888-436-3722) 7.6kW 1Ø, 11.4kW 3Ø PWRcell Inverter w/ CTs and CT Adapter Model: APKE00014, APKE00013 Solar-plus-storage is simple with the Generac PWRcell Inverter. This bi-directional, REbus™-powered inverter oers a simple, ecient design for integrating smart batteries with solar. Ideal for self-supply, backup power, zero-export and energy cost management, the PWRcell inverter is the industry’s most feature-rich line of inverters, available in single-phase and thr ee-phase models. ADDITIONAL FEATURES • Single inverter for grid-tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User-selectable modes for backup power, self-supply, time-of-use and zero-export • Free system monitoring included via PWRview Web Portal and Mobile App FEATURES: No autotransformer or battery inverter needed User-selectable modes Free system monitoring AC OUTPUT/ GRID-TIE MODEL APKE00014 MODEL APKE00013 RATED AC POWER OUTPUT 7600 W 11400 W AC OUTPUT VOLTAGE 120/240, 1Ø VAC 120/208, 3Ø VAC AC FREQUENCY 60 Hz 60 Hz MAXIMUM CONTINUOUS OUTPUT CURRENT 32 A, RMS 32 A, RMS GROUNDFAULT ISOLATION DETECTION Included Included CHARGE BATTERY FROM AC Yes Yes THD CURRENT< 2 %< 2 % TYPICAL NIGHTTIME POWER CONSUMPTION < 7 W < 7 W AC OUTPUT/ BACKUP MODEL APKE00014 MODEL APKE00013 RATED AC BACKUP POWER OUTPUT 8000 W 8000 W MAXIMUM AC BACKUP POWER OUTPUT 10000 W 10000 W AC BACKUP OUTPUT VOLTAGE 120/240, 1Ø VAC 120/240, 1Ø VAC AC FREQUENCY 60 HZ 60 HZ AC CIRCUIT BREAKER 50 A 50 A THD VOLTAGE< 2 %< 2 % AUTOMATIC SWITCHOVER TIME < 1 Seconds < 1 Seconds TYPICAL NIGHTTIME POWER CONSUMPTION 30 W 30 W DC INPUT MODEL APKE00014 MODEL APKE00013 DC INPUT VOLTAGE RANGE 360420 VDC 360420 VDC NOMINAL DC BUS VOLTAGE 380 VDC 380 VDC MAX INPUT CURRENT 20 A 30 A REVERSEPOLARITY PROTECTION YES YES GROUNDFAULT ISOLATION DETECTION YES YES TRANSFORMERLESS, UNGROUNDED YES YES DC INPUT/ BATTERY MODEL APKE00014 MODEL APKE00013 MAXIMUM CONTINUOUS POWER 8000 W 8000 W INTERNAL DC DISTRIBUTION BREAKERS 4X 2P30A 4X 2P30A DC FUSES ON PLUS AND MINUS 40 A 40 A 2POLE DISCONNECTION YES YES EFFICIENCY MODEL APKE00014 MODEL APKE00013 PEAK EFFICIENCY 97 %98 % CEC WEIGHTED EFFICIENCY 96.5 %97.5 % Generac Power Systems, Inc.S45 W29290 Hwy. 59, Waukesha, WI 53189www.Generac.com 1-888-GENERAC (1-888-436-3722) Specifications Specifications subject to change without notice. FEATURES AND MODES ISLANDING3 Yes GRID SELL Yes SELF CONSUMPTION Yes PRIORITIZED CHARGING FROM RENEWABLES Yes GRID SUPPORT ZERO EXPORT Yes ADDITIONAL FEATURES SUPPORTED COMMUNICATION INTERFACES CANbus, RS4854, Ethernet SYSTEM MONITORING PWRview Web Portal and Mobile App CRITICAL LOADS DISCONNECT3 Yes MANUAL INVERTER BYPASS SWITCH Automatic WARRANTY 10 Years STANDARDS COMPLIANCE SAFETY UL1741 SA, CSA 22.2 GRID CONNECTION STANDARDS IEEE1547, Rule 21, Rule 14H EMISSIONS FCC part15 class B DIMENSIONS AND INSTALLATION SPECIFICATIONS WIRE GAUGE RANGE 10 - 8 AWG TOTAL AC KNOCKOUTS X SIZE 2“ x 0.75“, 2 x 1“ TOTAL DC KNOCKOUTS X SIZE 5“ x 1“ DIMENSIONS L,W,H24.5“ x 19.25“ x 8“ WEIGHT 62.7 lb COOLING Forced convection NOISE < 40 dBA OPERATING TEMPERATURE -20 to 50 °C* PROTECTION RATING NEMA 3R INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED PWRcell battery module MODULE STRING SIZE PER PV LINK OPTIMIZER 2-9 PV modules MAXIMUM RECOMMENDED DC POWER FROM PV 10kW (1Ø), 15kW (3Ø) BATTERIES PER INVERTER Up to 2 3 3Ø inverters oer islanding for 1Ø loads, 4 Modbus,*Reduced power at extreme temperatures RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSDC/DC CONVERTERS CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSModel APKE00007, PWRcell Battery CabinetModel A0000391219, 2.85kWh PWRcell Battery ModuleCertification Model Reference: BJ-DCB05ZKAXModel APKE00008, PWRcell Spacer KitModel APKE00009, PWRcell Upgrade KitCertification Model Reference for Battery Configurations: PWRcell 9, PWRcell 12, PWRcell 15, PWRcell 17 FEATURES & BENEFITS • Connect 2 PWRcell Battery Cabinets to a single PWRcell Inverter for 34.2kWh of storage • Best-in-class battery backup power • Plug-and-play with PWRcell Inverter and PV Link™ • Time-of-use (TOU) and zero-export ready • Residential and commercial application ready BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY PWRcellBattery Cabinet PWRcell 1717.1kWh 6x Battery Module PWRcell 1514.3kWh 5x Battery Module+ Module Spacer Kit PWRcell 1211.4kWh 4x Battery Module PWRcell 98.6kWh 3x Battery Module+ Module Spacer Kit OR OR OR SPACER SPACER PWRcellBattery CabinetBack PanelModuleSpacer Kitx1 BatteryModulex5PWRcellBattery CabinetFront Panel The PWRcell™ Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need, small or large. No other smart battery oers the power and flexibility of PWRcell. Whether for backup power or smart energy management, PWRcell has power and capacity options for every need, without sacrificing flexibility or function. PWRcell BATTERY CABINET DESIGN The PWRcell Battery Cabinet allows system owners the flexibility to scale from the economical 8.6kWh PWRcell 9 to the massive 17.1kWh PWRcell 17 by installing additional battery modules to the PWRcell Battery Cabinet. When needs change, an existing PWRcell Battery Cabinet can be upgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration. Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528139 REV C ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. UPGRADING PWRcell Inside of the PWRcell Battery Cabinet, battery modules are stacked two deep on three levels, allowing for up to six modules to be connected in series. You can upgrade an existing PWRcell Battery Cabinet by adding Battery Modules and a Module Spacer (APKE00008) if required. PWRcell 9 and PWRcell 15 require a module spacer. Generac oers a convenient PWRcell Battery Upgrade Kit (APKE00009) to help replace lost or misplaced hardware. A PWRcell Battery Upgrade Kit may be purchased from your Generac distributor. Refer to the table to the right for material requirements related to upgrading the PWRcell Battery Cabinet. UPGRADE MATERIAL REQUIREMENTS ENDING CONFIGURATION STARTING CONFIGURATIONPWRcell 17 PWRcell 15 PWRcell 12 PWRcell 9 + 3 x PWRCell Mod+ 2 x APKE00009*+ 2 x PWRCell Mod+ 1 x APKE00009*+ 1 x PWRCell Mod+ 1 x APKE00009* PWRcell 12 + 2 x PWRCell Mod+ 1 x APKE00009*+ 1 x PWRCell Mod+ 1 x APKE00008 PWRcell 15 + 1 x PWRCell Mod+ 1 x APKE00009* *APKE00009 (Upgrade kit) only required if original hardware is unavailable PWRcell™ BATTERY CONFIGURATIONS 9 12 15 17 BATTERY MODULES:3 4 5 6 USABLE ENERGY:8.6kWh 11.4kWh 14.3kWh 17.1kWh POWER RATED CONTINUOUS: 3.4kW 4.5kW 5.6kW 6.7kW POWER 60 MINUTES:4.2kW 5.6kW 7.0kW 8.4kW POWER 2 MINUTES:5.0kW 6.7kW 8.4kW 10.0kW REbus™ VOLTAGE INPUT/OUTPUT:360-420 VDC MODULE VOLTAGE:46.8 VDC ROUNDTRIP EFFICIENCY:96.50% OPERATING TEMPERATURE FAHRENHEIT CELSIUS:41 to 113 °F 5 to 45 °C RECOMMENDED AMBIENT TEMPERATURE FAHRENHEIT CELSIUS: 55 to 86 °F 13 to 30 ºC MAXIMUM INSTALLATION ALTITUDE FT M:9834 (3000) DIMENSIONS, L x W x H IN MM:22" x 10" x 68" 559 x 254 x 1727 WEIGHT, ENCLOSURE LB KG:115 (52) WEIGHT, INSTALLED LB KG:280 (127)335 (152)390 (178)445 (202) WARRANTY LIION MODULES:10 Years, (7.56MWh) WARRANTY ELECTRONICS AND ENCLOSURE:10 Years COMMUNICATION PROTOCOL:REbus™ DC Nanogrid™ COMPLIANCE:UL 9540, UL 1973, UL 1642, CSA 22.2 BATTERY CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-40RAIL 232-02449,232-02450,232-02451 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAILPROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAILPROPERTIES SKU FINISH 232-02481 MILL 232-02482 CLEAR232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT snapnrack.com 51 System Bonding Methods Grounding Specifications RAIL CHANNEL NUT MODULEFRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACKULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S.WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUNDLUG, 6-12 AWG SNAPNRACK BONDINGCHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP(2 TOTAL)RAIL SPLICEASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICEASSEMBLY SS BONDING PIN(2 TOTAL) snapnrack.com 52 Grounding Specifications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACKULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SSWITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP TO EGC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT snapnrack.com 53 Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP ENPHASEMICRO-INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP SOLAREDGEOPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. Install Note: SnapNrack Ground Lug only Listed for use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 ft-lbs. Grounding Specifications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side of the rail for the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs for #10- #14 solid and stranded copper, 25 in-lbs for #8 stranded copper, and 35 in-lbs for #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level of 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing.• SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 ft-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail. • Ilsco hardware connection to rail: 5 ft-lbs. Torque for lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note:RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT snapnrack.com 55 Ground Path Details - DynoBond Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMP M = MIDCLAMPE = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the frame flange of adjacent modules. 1/953 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes:1.ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2015 International Building Code, by International Code Council, Inc. 3.2015 International Residential Code, by International Code Council, Inc. 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria:Risk Category II Seismic Design Category = A - E Basic Wind Speed (ultimate) per ASCE 7-10: up to 190 mph Ground Snow Load = 0 to 120 (psf) This letter certifies that the loading criteria and design basis for the SnapNrack Ultra Rail Racking System with UR-40 Rail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA August 6, 2019 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the SnapNrack Ultra Rail Racking System with UR- 40 Rail, as presented in PZSE Report # 2017-03227.11, "Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re: Report # 2017-03227.11 – SnapNrack Ultra Rail Solar Photovoltaic Racking System with UR-40 Rail RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-112Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.800Sinclair, Rodney147 Westhampton RdNorthampton, MA 0106208/03/2020SUBMIT FOR PERMIT