Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
44-134 (7)
1006 FLORENCE RD BP-2021-0114 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:44- 134 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit BP-2021-0114 Project# JS-2021-000182 Est.Cost: $20000.00 Fee: $112.50 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VIVINT SOLAR DEVELOPER LLC 062490 Lot Size(sq.ft.): 130897.80 Owner: LEBLANC ANDREW zoninp,: Applicant: VIVINT SOLAR DEVELOPER LLC AT. 1006 FLORENCE RD Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT A - Attn Savina Cervone (413) 259-8044 O WC CHICOPEEMA01022 ISSUED ON.7/29/2020 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF MOUNT SOLAR PV - 289 MODULES, 9.1 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. miilcling Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 7/29/2020 0:00:00 $112.50 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner � 4 Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 PloUSite P1an& Other Sp APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO WE LING g SECTION 1 -SITE INFORMATION JUL 2O2O 1.1 Property Address: Thi tion toLbeompleted y offi e ( (� OF sunINSPECTIONSim 9 F�ZSr'el a- Map / NORTILi Wit Zone Overlay District 012 Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: &4C' 1006 'P(6rtA&CX, V Name(Print) Current Mailing Address: 1 jj3-47 2-37S1 Telephone Signature 2.2 Authorized Agent: 150 Padgette St, Chicopee, MA 01022 Name(Priny Current Mailing Address: fitur413-217-4033SignTelephone $a lAr ca SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical b (b) Estimated Total Cost of l 60 Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total = 0 +2 + 3+4 + 5) Check Number d This Section For Official Use Only ( _ Date Building Permit Number ( 1 J( Issued: Signature: I -cw Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) E7Roofing ❑ Or Doors I] Accessory Bldg. ❑ Demolition ❑ New Signs 101 Decks [M Siding [al Other[PI1l �a ar Brief Description of Proposed q ! Work: Installation of roof mounted photovoltaic solar systems# of modules Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. S QR- G. Q c"l Signature of Owner Date I, Vivint Solar Developer, LLC as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name, Signatu a of Owner/Agent Date t SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Douglas Caverly CS-062490 License Number 150 Padgette St Unit B, Chicopee, MA 01022 03/02/2022 Address Expiration Date Z: d 413-259-8044 Signature Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ VIVINT SOLAR DEVELOPER, LLC/Douglas Caverly 170848 Company Name Registration Number 1800 W Ashton Blvd, Lehi UT 84043 1/4/2022 Address Expiration Date Telephone 413-259-8044 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildiniz permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts Department of Industrial Accidents � Office of Investigations �- - 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Co ntractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer, T.U. Address: 1800 W Ashton Blvd City/State/Zip: Lehi, UT 84043 Phone#: 801-845-0286 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 253 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6 E]New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition workingfor me in an capacity. employees and have workers' Y P tY• 9. EJ Building addition [No workers' comp. insurance comp. insurance.l required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.[S Other Solar Installation comp. insurance required.] •Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information, t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that Is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: 'Zurich American Insurance Company _ Policy#or Self-ins. Lic.#: W 5096014-05 Expiration Date: 11/01/2020 Job Site Address: (Od 6 (�fy_ -f'A City/State/Zip: 14rg,, ,. /�1/, Q OX7, Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the ins and enaltte perjury that the information provided above is true and correct Signature: Date: 11/20/2019 _ Phone#: 801-845-0 6 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards ConstrUCIIIO 'SUpervlsor CS-062490 Expires:03/02/2022 DOUGLAS PCAVERLY 178 MILLER STREET LUDLOW MA 01056 I.Of.,ti I I l VX'\`. Commissioner (J7v //...... office of Consumer Affairs A Buslnes3 Regulation HOME IMPROVEMENT CONTRACTOR TYPE:SUoolemeN I Card Registration La ILretlon 170846 01/04,2022 VIVINT SOLAR DEVELOPER LLC, DOUGLAS CAVERLY 1800 W.ASHTON BLVD. LEHI,UT 84043 Undersecretary AC-"R" CERTIFICATE OF LIABILITY INSURANCE DATE IMM/DDIYYYY) llile � 1/22120 9 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 jA/C no,Exit: A/CC,Not: DENVER,CO 80202-5534 E'MAIL ADDRESS: AM!Denver.CertRequesl@marsh.com Fax:212-948-4381 INSURER(S)AFFORDING COVERAGE NAICN_ INSURER A:AXI$ $dally EJrope SE INSURED vivint Solar Developer,LLC INSURER B:Zurich American Insurance Company 1800 W Ashton Blvd INSURER C:AmericanZurichInsurance Company 40142 _ Lehi,UT 84043 INSURER D INSURER E: INSURER F:— COVERAGES :COVERAGES CERTIFICATE NUMBER: SEA-003174122-21 REVISION NUMBER: 8 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE,AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID_CLAIMS. INSR. `ADOL SUER ..PS—LILY EFF - ---- _---------_.-- LTR TYPE OF INSURANCE POLICY NUMBER POLICY EXP LIMITS MMMWntyyl A X COMMERCIAL GENERAL LIABILITY 3776500119ES 12101/2019 11/01/2020 EACH OCCURRENCE S 1,000,000 CLAIMS-MADE X OCCJR DANIAG 1,000,000 .. MED EXP Any one ) S 10,000 PERSONAL 6 ADV INJURY _ S 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 2,000,000 X POLICY L]UpECf O LOC PRODUCTS-COMPIOP AGG S 1000,000 OTHER: -- S B AUTOMOBRELIABNJTY BAP509601505 11/01/2019 11101/2020 En accde�lj tNGL $ _ 1,000,000 X ANY AUTO BODILY INJURY(Per person) S OWNEDSCHEDULED BODILY INJURY(Per accident) $ i AUTOS ONLY C AUTOS X HIRED I X NON-OWNED -1AGES AUTOS ONLY AUTOS ONLY S X UMBRELLA LIAR X3776500219ES 12/0112019 11101/2020 5,000,000 I OCCUR I EACH OCCURRENCE S tl^_ EXCESS LIAR CLAMS-MADE: AGGREGATE S _ 5,000,000 DED RETENTION 1 S C WORKERS COMPENSATION W 509601305(AOS) 11101719 X ANDEMPLOYERS'LIABILITY STAT TE RH B YIN WC509601405(MA) 1110112019 1110112020 ANYPROPRIETOR/PARTNER/EXECUTIVE 1,000,000 OFFICER/MEMBER EXCLUDED? r NIA EL EACH ACCIDENT _ S ______ (Mandatory In NH) I E.L DISEASE-EA EMPLOYE S 1,000,000 I ifes,desc be under 1,000000 D SCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S i I I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION Town of Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 212 Main Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Northampton,MA 01060 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Jon Lindstrom rr j . r ©1980-2016 ACORD CORPORATION. All rights reserved. ACORD 26(2016103) The ACORD name and logo are registered marks of ACORD V'v'nt1800 W Ashton Blvd. • Lehi, UT 84043 Structural Group J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com July 23, 2020 Re: Structural Engineering Services Leblanc Structure 1006 Florence Rd, Northampton, MA S-6412321; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Structure: The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Section 1: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section 2: Dimensional lumber - 2x6 at 24" on center. Based on survey photos, the framing size and spacing was verified through a tap test and dowel measurement. A tap test entails tapping the roof or ceiling to identify location of rafters and getting a rafter spacing measurement. The dowel measurement entails drilling through the roofing and sheathing or ceiling and using a dowel or wire to determine the framing depth. B. Loading Criteria 9.49 PSF = Dead Load (roofing/framing) 3.00 PSF = Dead Load (solar panels/mounting hardware) 12.49 PSF =Total Dead Load 20 PSF = Roof Live Load 40 PSF = Ground Snow Load (based on local requirements) Wind speed of 117 mph (based on Exposure Category B -the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) Page 1 of 2 wivint. so l a r C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). 2. The solar panels are 1Y2' thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir is 235 lbs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2015 IBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 72 72 72 48 48 48 Max Uplift Load lbs 133 87 49 223 73 21 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2015 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. H of M Regards, A SgS4y110, J. Matthew Walsh, PE _ / J 11 MATThE (\m MA License No. 54057 �fw� p Li y 1 a NO. 54057 �O FGSTER�� sSfONAI 07/23/2020 Page 2of2 vivant. solar PV STRING(S): OOF SECTION(S): SYSTEM LEGEND a9 1)SLOPE.31 ® #1)14 MODULES AZIMUTH-167 PV SYSTEM SIZE: ® MATERIAL-COMPOSITION NEW 9.100MW DC I 7.600KW AC #2)14 MODULES SHINGLE O2 SLOPE-30 EXISTING INTERIOR MAIN SERVICE PANEL POINT AZIMUTH-167 OF INTERCONNECTION TIED TO DETACHED UTILITY METER#43958891. MATERIAL-COMPOSITION SHINGLE �P NEW SMART METER.LOCATED WITHIN 10'OF MSP. ® NEW PV SYSTEM AC DISCONNECT. LOCATED WrrHIN 1d OF MSP. I 1 NEW PV SYSTEM INVERTER-.SolarEEge Teohnol give SE7600H-US(RSD EQUIPPED) 28 NEW JINKO SOLAR JKM325M-60HBL MODULES. NEW SOLAR EDGE P340 OPTIMIZERS,MOUNTED ON THE BACK OF EACH MODULE. NEW JUNCTION BOX.(MOUNTED TO PV MODULE) O � N LL ui Z n EXISTING DETACHED UTLRY METER #43958891 ui LL O O J w O Ll o' O � O o MFAT v vivint.Solar 1.877.404.4129 LEBLANC RESIDENCE 1006 FLORENCE RD FLORENCE,MA,01062 UTILITY ACCOUNT#:06912-66041 " SERVICE#: ' ' �� SITE PLANCENTER:MA-04 PV 1 .0 DATE:7119@020 SCALE:1/8"=V-0 DRAWN BY:DIN MOUNTING LEGEND ROCK-R COUPLING MD QAMP 2 ROCK-IT COUPLING MID CLAMP S1.0 tMID 4T 3.0 COUPLING ROCK-IT ROCK-IT SLIDE LAMP O PEDESTAL METAL ROCK-LIT Y16'x3/8' - FLASHING COUPLING SHELFHEX FLANGE BOLT 300 SERIES SS ROCK-IT COUPLING SHELF ISOMETRIC VIEW COMPSHINGLESSS LAGSCREW TORQUE=13x2 FT{BS. SIDE VIEW %t1/2'TIE PLATEFUNGE BOLT SIDE NEW 300 SERIES SS ® O B ILSCO SGB 4 (Z)ROOK-IT 3.0 MOUNT DETAIL „o„R,u,l GROUNDING LUGS rqf ro 5R%t 5 1.0 i sl.o u1.LB11NGFORECOFI3T6N:10] (i)ROCK-Ir 3.0 COUPLING ASSEMBLY wEK'nT:]34. 51.0 MnrowM TOP VIEW CLAMP.ATTACHMEN7 CLAMP ATTACHMENT PERMITTED COUPLING CANTILEVER U3 OR LESS COUPLING CLAMP SPACING NDSCAPE=MA%72'(6'-0') I PORTRAIT=MAX 49'(4'-0') COUPLING CLAMP RAFTER MODULE A1 ROCK-R SLIDE MOD LE METAL MODULE FLASHING EPDMBONDEOWASHER RAFTER RAFTER FORMS WATERTIGHT SEAL TRUSS I I =eNO ep AMP SPA.IN 'r _ :i'• 2WAT24'O.C. PV SYSTEM MOUNTING DETAIL 2WART24'O.C. 5 ODULES IN PORTRAIT LANDSCAPE I L-PO TRAI S1A xor TO_ CLAMP SPACING COMP SHINGLES 21/ MIN T MIN AND 6'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MIN 5118'DIAM ONE ROLE STEEL STRAP CONDUIT SS LAG SCREW PV MODULE.TYP.MOUNT 1 TOROUE=1312 FT-LBS. TO FRAMING OF EXISTING ROOF TYPE,PARALLEL S 1 0Y'r `. o I a r WITH PLANE OF ROOF CONDUIT MOUNT BRACKET `, `,' iT 6`MAXIMU 1.877.404A129 SECTION VIEW t t —- FLASHING OR TILE STRAP LEBLANC RESIDENCE 1 1006 FLORENCE RD FLORENCE,MA,01062 3 SECTION VIEWUTILITY ACCOUNT#06912-56041 s l.o MarowXa /'7"VV ARRAY TYP.ELEVATION CONDUIT MOUNTING DETAIL st.o T° E SERVICE t381t2321 MOUNT DETAILS DDDR: S 1 .0 DAIS:71192020 SCALE:NOT TO SCALE DRAWN 6Y:DIN Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 9100 Tag Description 06AWG 4of Conductors/Color Conduit Type Conduit Size AC System Size(Watts) 7600 1 DC-to-DC Converter Output(PV Wire) 2(V.,V-)B/R Free Air N/A Total Module Count 28 1 EGC(Bare) 1 BARE Free Air N/A o 2 DC-to-DC Converter Output(THWN-2) 4(2V.,2V-)B/R EMT 1/2" vo on2 EGC(THWN-2) 1(GRN) EMT 1/2" <3 Inverter Output(THWN-2) 3(1-1,1-2,N)B/R/W EMT 3/4"3 EGC(THWN-2) 1(GRN) EMT 3/4" to p y 1Service Feeder(THWN-2) 12 AWG 3(Ll,L2,N)B/R/W EMT 3/4" �- 4 GEC(THWN-2) SAWG 1(GRN) EMT 3/4" •� o m •sssr. .. v as n as u` ry a a 5olarEdge PV System SMART Meter z m SE7600H-US . C on forms to ANSI OF m C12.1-2008 Z o Square D DU222RB Point of Interconnection,Supply Side 705.11 > 240V/60AUnfused, > Z External Rapid Shutdown .. N NEMA311,with 75'C Disconnect;Square D w w Z terminations D222NRB 240W60A J J U N Fused,NEMA3R,with 75'C Q F terminations Z Z STRING 2:14 PV t M' MODULES Existing Murray SHEET W/OPTIMIZERS 240V/2ODA Ser vi ce Panel, NAME: 2 r] LINE Single Phase,with 200A Ma in Disconnect C A c 3 STRING 1:14 PV 1 2 J MODULES NEMA4 Junction Boz (D-:: LO A 40A M O W/OPTIMIZERS 3 4 SHEET NUMBERIj : 28 PV MODULES PER INVERTER=9100 WATTS STC Yisible/Lockable'Knife'AC Msibl lncka ble'Knife'AC Minimum GECsize4 Disconnect Disconnect In Sightof Tap AWG copper W PV Module Rating @ STC Conductor Calculations Module Make/Model Jinko Solar JKM325M-60HBL Max.Power-Point Current(Imp) 9.68 Amps Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature ,n calculations from Table 310.15(B)(1)&310.15(B)(2)and raceway fill adjustments from 310.15(C) Max.Power-Point Voltage(Vmp) 33.6 Volts o m (1).Conduit on the roof shall be installed no less than 1"above the roof deck. c a e Open-Circuit Voltage(Voc) 41.1 Voltsu v PV Circuit conductor ampacity is constrained using the 75'0 column with the continuous duty ¢ � Optimizer solarEdge P340 Short-Circuit Current(Isc) 10.2 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments LL ?; no u DC Input Power 340 Watts Max.Series Fuse(CCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. o0 o . DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75'C column or the 90'C column with the ¢ >, DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(0)& DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.28 %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, Max.string rating inverter dependent.See SE documents. the continuous duty uprated current. Inverter Make/Model SolarEdge SE760OH-US AC Output Current According to art.690.8(B)(1) 32 Amps More information about conductor calculations can be provided upon request. CEC Efficiency 99 % Nominal AC Voltage 240 Volts Calc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor x Conduit Fill Adj.Factor>=Output Current (Tag 1 Under Array): AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A Cont.Max Output Current 32 Amps (Tag 2 On Roof): DC Max Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art.690.8, DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A Input Short Circuit Current 45 Ams Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c),310.15(B)(16), p p (Tag 3 Exterior): Max Output Fault Current 40 A/20 ms Chapter 9 Table 4,5,&9.Location specific temperature obtained from Inverter Output:8 AWG rated 50 A, 50 A>=40 A • ASHRAE 2017 data tables. (Tag 4 Exterior): fir ASHRAE 2017-WESTFIELD-BARNES AP Service Feeder:6 AWG rated 65 A, 65 A>=60 A •� o Highest Monthly 2%D.B.Design Temp.:33'C m Lowest Min.Mean Extreme D.B.:-25.4'0 •� "' v w Power Production Calculation v` Service Rating:200 Amps PV Breaker Rating:40 Amps ,O1„ 40A<=200A,OK a v a Z m OCPD Calculations > Z W a ¢ � w = , Breakers sized according to continuous duty output current.PV circuit nominal current based off inverter continuous output current X(1.25[art.690.8(A)]). F a J Other Notes Inverter 1: H-US Max Output=32 A x 1.25[art.690.8(A)] SHEET •Designed according to and all code citations are relevant to the 2020 National Electrical Code. =40 A c==40 40 A A((CCPD) •All interior raceways carrying DC current shall be metallic. NAME: system output current w/continuous duty=40<=40A(System CCPD) N W do m Z a SHEET NUMBER: N W s DocuSign Envelope ID:C3A93780-5548-4F67-BA02-CDD304582885 SmartPower. Fixed Plan vivintsolar, Comfortable living at a price you can control. Transaction Date: July 13,2020 13:22 PM PDT Service No: 6412321 Customer Name &Contact Information Services Information Andrew LeBlanc 1006 Florence Rd Name(s): Property Location: Contract Co-Signer Florence MA 01062 E-Mail: andrewsl7l@aol.com Approximate Installation Start Date and Completion Date: 1/9/2021 Phone: 4134783755 Date of Customer Signature: July 13,2020 14:24 PM MDT Our Promises: Your Commitment: We will design, install, operate, and maintain a solar Pay the Monthly Payment each month energy system at your property Continue service with your utility We will not place a lien on your home, but will file a Make certain representations and warranties notice of our ownership of the system Confirm that you own the property We guarantee that the system will produce a certain Respond promptly to our sales and support amount of energy teams when scheduling and completing Our work will be free from material defects for 25 years, paperwork and all roof penetrations will be watertight, for 10 years You will not be responsible for any personal The solar panels and inverters come with standard property taxes on the system manufacturer warranties =. Maintain a broadband Internet connection The Monthly Payment includes a $7.50 monthly discount Keep your roof in good condition throughout for paying by automatic debit from your bank account the Initial Term If you move,you may: Atthe end of 25 years,you may: Transfer this agreement to the buyer of your home; Renew the Agreement; Prepay the agreement, Purchase the System; or Purchase the system if 6 years have passed; or Request that we remove the System at no Relocate the system under certain circumstances additional cost. You may cancel this Agreement anytime prior to commencement of any work at or near your property associated with installation of the System. Vivint Solar Developer, LLC (EIN: 80-0756438) is a licensed contractor in each state in which we operate Including Massachusetts. Our contractor license numbers are included as part of Exhibit C to this Lease. For information about our licenses, please visit http://www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING "PRESCREENED" OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN & OPT-OUT NOTICE BELOW IN SECTION 25 FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. le iVotice of Cancellation may be sent to this address Vivint Solar Developer, LLC u 1800 W Ashton Blvd Phone:, 877.404.4129 E-Mail: help@vivintsolar.com Lehi, UT 84043 Fax: 801.765.5758 Website vivintsolar.com Copyright© 2020 Vivint Solar Developer, LLC. All Rights Reserved. DocuSign Envelope ID:C3A93780-5548-4F67-BA02-CDD304582885 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT. These documents are incorporated into this Agreement and apply to the relationship between you and us: (1) Lease Agreement, (2) General Provisions, (3) Customer Packet; and (4)any attachments, disclosures and exhibits, as applicable. DS BY INITIALING, YOU ACKNOWLEDGE RECEIPT OF EXHIBIT A— LEASE DISCLOSURES AND AGREE TO MAKE 9 PAYMENTAS SET FORTH IN EXHIBITA. B. WE HAVE NOT GUARANTEED, PROMISED OR OTHERWISE REPRESENTED ANY REDUCTION IN ELECTRICITY COSTS IN RELATION TO THE SYSTEM THAT WILL BE INSTALLED ON YOUR PROPERTY. C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. D. IF YOU DO NOT ELECT ANY OF THE END-OF-TERM OPTIONS SET FORTH IN SECTION 2(A), THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS. CONSULT SECTION 2 FOR MORE INFORMATION. E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO A SALES REPRESENTATIVE. F. You have the right to require us to have a performance and payment bond. G. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both you and us, before any work may be started. H. YOU, THE CUSTOMER, MAY CANCEL THIS CONTRACT AT ANY TIME BEFORE MIDNIGHT OF THE THIRD (3RD) BUSINESS DAY AFTER THE TRANSACTION DATE. SEE THE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN YOU THE"NOTICE OF CANCELLATION". REPRESENTATIVE: DocuSignedby: CUSTOMER(S): DoeuSignedby: ETrevor VWA Qla,�MW �,t16AVt.t Signature: 5 Signature: Printed Name: Trevor Young Printed Name: Andrew LeBlanc Salesperson No.: 95368 Date: July 13,2020 14:24 PM MDT Date: July 13,2020 14:24 PM MDT Signature: FOR OFFICE USE ONLY Printed Name: THIS AGREEMENT IS NOT EFFECTIVE NOR BINDING UPON VIVINT SOLAR DEVELOPER, LLC UNTIL SIGNED Date: BY AN AUTHORIZED REPRESENTATIVE. VIVINT SOLAR DEVELOPER, LLC Signature: Printed Name: Date: 7r�5�zo—�}(� Processing No.: 9501 164 Copyright© 2020 Vivint Solar Developer, LLC. All Rights Reserved. LEASE(2/2020, v4.1) I Page 18 of 18