60 Washington garage R1 -7 23 2020WASHINGTON AVENUE DRYAD'S GREEN47' - 6"14' - 2"27' - 6"77' - 0"75' - 0" (EXST) GARAGE (EXST) 2-STORY SETBACK15' SIDESETBACK 15' SIDE SETBACK10' FRONTSETBACK 10' FRONTSETBACK20' SIDECOVERED ENTRY 62' - 11"10' - 0"3' - 0"9' - 8"19' - 4"380 SF ASPHALT DRIVEWAY 22' - 9 1/2"41' - 6"12' - 0" 3' - 0" (EXST) 2-STORY (EXST) 2-STORY A1 1 143 1/2"11"11" 2 A1 NEW 20 MIN FIRE- RATED STL DOOR 7 3/4" STEP EXISTING STAIR NEW CONTINUOUS WD HANDRAIL AT WALL R @ 7 3/4"3 NEW 2X4 STUD WALL GWB BOTH SIDES EXISTING STAIR TO BASEMENT DN 160 SF OFFICE 137 SF STORAGE 4 A1 CLOSED CELL SPRAY FOAM @ EXISTING ROOF JOISTS 1/2" GWB CLG CLOSED CELL SPRAY FOAM @ EXISTING WALLS 1/2" GWB FINISH BUILT UP FLOORING ON EXISTING CONCRETE SLAB: 3 LAYERS 2" RIGID XPS 2 LAYERS 23/32" T&G SUBFLOOR FINISH FLOOR EXISTING SLAB-ON-GRADE 2X4 STUD WALL TO ROOF CLOSED CELL SPF BETWEEN STUDS SINGLE TOP PLATE AT EXISTING ROOF DECK CLOSED-CELL SPF BETWEEN EXISTING 2X10 RAFTERS 1/2" GWB CEILING 1/2" GWB WALL FINISH LAMINATE FINISH FLOOR ON 2X 23/32" T&G SUBFLOOR GLUED AND SCREWED FLOATING ON (3) LAYERS 2" RIGID FOAM INSULATION0"CLOSED CELL SPF BETWEEN EXISTING STUDS 1/2" GWB BOTH SIDES PT 2X4 PLATE NAILED TO SLAB 24" OC SILL SEALLER BELOW EXISTING GARAGE DOOR & MOTOR DAVID WHITEHILL AIA davidwhitehill@gmail.com 347-514-2567 60 WASHINGTON AVENUE NORTHAMPTON, MA 01060 7/23/2020 10:28:25 AM A1 As indicated ZONING, PLAN & NOTES WHITEHILL - HOECHSTETTER 60 WASHINGTON AVENUE NORTHAMPTON, MA 01060 GARAGE CONVERSION 23 July 2020 PERMIT SET 3/32" = 1'-0"3 EXISTING SITE PLAN - NO CHANGE PROPOSED URB ZONING DIAGRAM ZONING INFORMATION PARCEL ID: 31A-196 ZONING DISTRICT: URB LOT AREA: 5100 SF 1. ALL WRITTEN NOTES AND SPECIFICATIONS TO BE CONSIDERED INTEGRAL TO DRAWINGS. SPECIFICATIONS SHALL GOVERN IN CASES OF CONFLICT/DISCREPANCY. 2. ALL WORK TO CONFORM TO STATE AND LOCAL CODES. 3. CONTRACTOR SHALL APPLY FOR ALL PERMITS. PERMITS SHALL BE OBTAINED PRIOR TO START OF CONSTRUCTION. 4. ALL WORK SHALL BE GUARANTEED AGAINS MATERIAL DEFECTS AND WARRANTIED FOR ONE YEAR AFTER FINAL PAYMENT. 5. CONTRACTOR TO COORDINATE ALL SUBCONTRACTORS INCLUDING CARPENTRY, CONCRETE, MECHANICAL, PLUMBING, AND ELECTRICAL. 6. CONTRACTOR AND SUB-CONTRACTORS SHALL VISIT SITE AND BECOME FAMILIAR WITH CONDITION PRIOR TO SUBMITTING PROPOSALS. NO EXTRA PAYMENTS DUE TO UNFAMILIARITY WITH CONDITIONS SHALL BE ALLOWED. 7. CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS. REQUIRED CLEARANCES/ACCESS TO EQUIPMENT SHALL BE COORDINATED. AND CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT PRIOR TO INSTALLATION. 8. ANY CONFLICT OR INCONSISTENCY FOUND IN DRAWINGS WITH NORMAL ACCEPTED CONSTRUCTION PRACTICE SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT FOR CLARIFICATION/RESOLUTION. 9. NO REVISIONS TO PROPOSALS BASED ON THESE DOCUMENTS SHALL BE ACCEPTED WITHOUR WRITTEN APPROVAL BY THE ARCHITECT. 10. DRAWINGS SHALL BE CONSIDERED "NOT TO SCALE." 11. ALL DIMENSIONS FROM FACE OF STUD OR FACE OF FOUNDATION UNLESS OTHERWISE NOTED. 12. PROTECT ALL TREES UNLESS OTHERWISE NOTED. GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRICAL SYSTEM FOR ADDITION AND CONNECTIONS TO EXISTING BUILDING. 2. ALL WORK TO BE IN CONFORMANCE WITH STATE AND LOCAL CODES AND NATION ELECTRICAL CODE (NEC). 3. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY CONDITIONS WHERE CODE-REQUIRED FIXTURE LOCATIONS/QUANTITY/TYPES ARE NOT INDICATED. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING QUANTITY OF FIXTURES AS REQUIRED BY CODE. 5. FIXTURES SHALL BE GROUND FAULT INTERRUPT TYPE AS REQUIRED BY CODE. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE WIRING AND CONNECTIONS FOR ALL SWITCHING, LIGHTING, AND RECEPTACLES. 7. ELECTRICIAN SHALL SHALL COORIDINATE WITH MECHANICAL CONTRACTOR AND SHALL PROVIDE POWER REQUIREMENTS OF MECHANICAL EQUIPMENT. 8. DISTRIBUTION PANEL SHALL BE CLEARLY LABELED (TYPED) AS TO AREAS SERVED BY EACH CIRCUIT. LABEL TO BE FIXED TO PANEL DOOR. 9. GROUND STEEL CONCRETE REINFORCEMENT. ELECTRICAL NOTES EXISTING BUILT AREA: 1400 SF (27.5%) EXISTING PARKING: 380 SF EXISTING OPEN SPACE: 3320 SF (65.1%) EXISTING BUILDING HEIGHT: 23 FT 1/2" = 1'-0"1 GARAGE FLOOR PLAN 1/2" = 1'-0"2 GARAGE CROSS SECTION 1/2" = 1'-0"4 GARAGE LONGITUDINAL SECTION