200113 SC Campus Police_Permit SetLIST OF DRAWINGS A0.1 A0.2 A1.1 A2.1 A6.1 A7.1 A7.2 A8.1 A9.1 M1 D1.1 GENERAL NOTES & SPECIFICATIONS PARTITION TYPES & CONSTRUCTION ASSEMBLIES FIRST FLOOR PLAN REFLECTED CEILING PLAN CONSTRUCTION DETAILS DETAILED PLANS & INTERIOR ELEVATIONS DETAILED PLANS & INTERIOR ELEVATIONS FURNITURE PLAN DOOR SCHEDULE & DETAILS HVAC MODIFICATION PLAN FIRST FLOOR DEMOLITION PLAN C&H Architects126 WEST STREET LOCUS PLAN Smith College Campus Police 13 January 2020 Permit Set College Contact: Karl Kowitz Smith College Northampton, MA General Contractor: Keiter Builders Northampton, MA Architect: Thomas RC Hartman, AIA Coldham & Hartman Architects Amherst, MA 413.549.3616 www.candharchitects.com C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A0.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set GENERAL NOTES & SPECIFICATIONS 2020-01-10 X1 Demo Dwg Notes.docx {Note: When PDF’ing - use custom paper size 5”x36”} GENERAL DEMOLITION NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND EXISTENCE OF BUILDING ELEMENTS AS SHOWN IN THE CONSTRUCTION DRAWINGS AND NOTIFY THE ARCHITECT OF DISCREPANCIES. 2. THE CONTRACTOR SHALL EXERCISE DUE DILIGENCE AND CAUTION WHEN REMOVING DEMOLITION MATERIAL AS TO NOT DISTURB SURROUNDING AREAS OF NEW AND EXISTING CONSTRUCTION. 3. EXISTING CONSTRUCTION TO REMAIN SHALL BE ADEQUATELY SHORED AND BRACED AS REQUIRED UNTIL NEW CONSTRUCTION IS COMPLETE AS REQUIRED TO BRACE THE STRUCTURE. 4. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN AND PROTECT AGAINST DAMAGE DURING DEMOLITION OPERATIONS. THE CONTRACTOR SHALL PREPARE AN AS- BUILT DRAWING OF CAPPED OR ABANDONED UTILITIES. 5. ALL SLAB AREAS TO BE CUT OR DEMOLISHED SHALL BE SCANNED FOR SUB-SLAB UTILITIES PRIOR TO CUTTING. UTILIITIES MAY INCLUDE, BUT ARE NOT LIMITIED TO: WATER, SEWER, ELECTRICAL, GAS, COMMUNICATIONS, FIRE ALARM AND FIRE SUPPRESSION. 6. REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND HVAC DRAWINGS FOR INFORMATION REGARDING THE REMOVAL OF EXISTING MECHANICAL, PLUMBING, ELECTRICAL AND HVAC EQUIPMENT. 7. IT IS NOT THE INTENT OF THESE DEMOLITION DRAWINGS TO SHOW EACH AND EVERY PIECE OF EQUIPMENT, FIXTURE OR MATERIAL TO BE REMOVED, RATHER TO SHOW THE GENERAL EXTENT OF THE WORK. INCLUDE ALL DEMOLITION WORK WHETHER OR NOT SPECIFICALLY INDICATED, INCLUDING CONCEALED CONDITIONS WHICH MAY BE REASONABLY INFERRED FROM THE EXISTING BUILDING CONFIGURATION AND WHICH IS REQUIRED TO COMPLETE NEW CONSTRUCTION. REFER TO ALL CONTRACT DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL DEMOLITION WORK. NEW CONSTRUCTION WORK SHOWN IN ARCHITECTURAL, MECHANICAL, STRUCTURAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION MAY REQUIRE ADDITIONAL DEMOLITION WORK NOT SHOWN ON DEMOLITION DRAWINGS. 8. THE OWNER RESERVES THE RIGHT TO SALVAGE, FOR HIS OWN USE, ANY AND ALL ITEMS NOTED TO BE “REMOVED” DURING THE COURSE OF CONSTRUCTION. ALL MATERIALS INDICATED TO BE REMOVED AND REUSED SHALL BE REMOVED, STORED AND PROTECTED BY THE CONTRACTOR. 9. SEE SPECIFICATION SECTION 01 11 16 MATERIALS BY OWNER & OWNER RESPONSIBILITIES FOR MORE INFORMATION REGARDING HAZARDOUS ABATEMENT DEMOLITION WORK. 10. DASHED LINES INDICATE THE EXTENT OF WORK TO BE REMOVED UNLESS NOTED OTHERWISE. SOLID LINES INDICATE THE EXTENT OF WORK TO REMAIN UNLESS NOTED OTHERWISE. 11. ALL EMERGENCY SYSTEMS (FIRE DETECTION, EMERGENCY LIGHTS, ETC.) SHALL REMAIN IN WORKING ORDER AT ALL TIMES. 2020-01-13 A0.0 General Notes.docx {Note: When PDF’ing - use custom paper size 5”x36”} GENERAL NOTES 1. ALL WORK SHALL BE IN COMPLIANCE WITH 9TH EDITION MA CODE (2015 IBC/IRC/IEC) WITH MASSACHUSETTS AMENDMENTS AND THE CURRENT MAAB & ADA REGULATIONS FOR ACCESSIBLE DESIGN. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL STATE AND LOCAL CODES AND ORDINANCES. 2. DIMENSIONS TO NEW CONSTRUCTION - ARE TO FACE OF CONCRETE & WOOD OR METAL FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS TO EXISTING CONSTRUCTION – ARE TO FACE OF FINISH. 3. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS ONLY. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY CONFLICTS EXIST. 4. THE CONTRACTOR SHALL APPLY FOR AND SUPPLY ALL BUILDING AND TRADE PERMITS. 5. THE CONTRACTOR SHALL AT ALL TIMES ADEQUATELY PROTECT THE BUILDING AND SITE FROM DAMAGE DUE TO CONTRACT OPERATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE AS A RESULT OF CONTRACT OPERATIONS AND SHALL REPAIR AND/OR REPLACE DAMAGED AREAS TO THEIR ORIGINAL CONDITIONS. 6. THE CONTRACTOR SHALL KEEP THE BUILDING CLOSED AND SECURE AT ALL TIMES AND PROTECT THE BUILDING AND SITE FROM THEFT AND/OR VANDALISM. 7. IF APPLICABLE, SEE ALTERNATES IN SPECIFICATIONS FOR ADDITIONAL WORK NOT NOTED ON DRAWINGS. 8. CONTRACTOR TO VERIFY ALL BEARING LINES ARE CONTINUOUS AND PROPERLY TRANSFERRED TO FOUNDATION. IMMEDIATELY BRING ANY STRUCTURAL DISCREPENCIES TO THE ATTENTION OF THE ARCHITECT. 9. WINDOW & DOOR WIDTH & HEIGHT DIMENSIONS GIVEN TO WINDOW & DOOR UNIT (NOT ROUGH OPENING). VERIFY EMERGENCY ESCAPE DIMENSIONS IN SLEEPING ROOMS (IF REQUIRED). PH DESIGNATES PLATE HEIGHT, WHICH IS THE ROUGH OPENING FOR FRAMING. 10. INSTALL DRAFTSTOPPING PER CODE AT ALL RATED ASSEMBLIES AND MECHANICAL CHASES. COORDINATE ACOUSTICAL INSULATION IN FLOORS AND WALLS WITH DRAFTSTOPPING REQUIREMENTS. 11. PROVIDE BLOCKING AS REQUIRED FOR, BUT NOT LIMITED TO, THE FOLLOWING: SHELVING, CABINETS, GRAB BARS, BATHROOM ACCESSORIES, HVAC, PLUMBING AND ELECTRICAL EQUIPMENT. 12. ALL EXTERIOR SLABS AND COVERED SURFACES TO BE SLOPED 1/8” PER FOOT MINIMUM AWAY FROM BUILDING. 13. SEE SPECIFICATION AND/OR DRAWINGS FOR DIRECTION ON OWNER FURNISHED AND/OR OWNER INSTALLED MATERIAL. 14. FE – INDICATES FIRE EXTINGUISHER, VERIFY FINAL TYPE WITH THE AUTHORITY HAVING JURISDICTION. 15. WHERE A NEW WALL IS A CONTINUATION OF AN EXISTING WALL, POSITION THE NEW WALL FRAMING OR PAD FRAMING SO THAT THE FINISH SURFACES SHALL BE FLUSH. 16. AT EXISTING FLOORS SCHEDULED TO RECEIVE NEW FLOORING, FILL AND PATCH HOLES, LOW SPOTS AND OTHER DAMAGED AREAS. LEVEL FLOORS AS NEEDED TO PROVIDED A SMOOTH AND LEVEL SURFACE FOR NEW FLOORING. 17. WHAT’S MISSING? AREA OF WORK N KEY PLAN C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A0.2 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set PARTITION TYPES & CONSTRUCTION ASSEMBLIES 3 5/8" METAL STUDS @ 16" O.C. 5/8" GWB TYPE 'X', VESTIBULE SIDE ARMORCORE LEVEL 3 PANEL 5/8" GWB TYPE 'X', DISPATCH/OFFICE SIDE GWB SEAMS AT STUDS, TYP. ARMORCORE 4" WIDE METAL BATTEN STRIP AT ALL ARMORCORE SEAMS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS ARMORCORE SEAMS OFFSET FROM GWB SEAMS, TYP. CEILING EXISTING DECK 1 HOUR FIRE RATED UL: U419 BULLET RESISTANCE: LEVEL III SECTION DETAIL PLAN DETAIL 3 5/8" METAL STUDS @ 16" O.C. 5/8" GWB 5/8" GWB CEILING DECK PARTITION TYPE 01A: FILL CAVITY WITH CELLULOSE INSULATION PARTITION TYPE 01A: ACOUSTIC SEALANT BOTHSIDES, TOP & BOTTOM OF WALL UN-RATED PARTITION SECTION DETAIL ARMORCORE LEVEL 3 PANEL 5/8" GWB TYPE 'X' GWB SEAMS AT FURRING, TYP. ARMORCORE 4" WIDE METAL BATTEN STRIP AT ALL ARMORCORE SEAMS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS ARMORCORE SEAMS OFFSET FROM GWB SEAMS, TYP. METAL OR WOOD FURRING, GC'S CHOICE EXISTING PARTITION (EXISTING FINISH, GWB OR PLASTER, TO REMAIN) CEILING EXISTING DECK 1 HOUR FIRE RATED UL: X BULLET RESISTANCE: LEVEL III SECTION DETAIL PLAN DETAIL 3 5/8" METAL STUDS @ 16" O.C. 5/8" GWB (ROOM SIDE) CEILING DECK UN-RATED PARTITION SECTION DETAIL 3 5/8" METAL STUDS @ 16" O.C. 5/8" PLYWOOD @ WAREHOUSE SIDE FILL CAVITY WITH CELLULOSE INSULATION CEILING DECK 5/8" GWB @ OFFICE SIDE UN-RATED PARTITION SECTION DETAIL4"+/-FILL CAVITY WITH CELLULOSE INSULATION 6" METAL STUDS @ 16" O.C. 1/2" PLYWOOD 5/8" TAPED GWB (OR TAPED PLYWOOD) 2X2 SUSPENDED ACOUSTIC TILE CEILING WITH INTEGRAL LIGHTING 3/4" PLYWOOD EXISTING FLOOR 6 MIL. POLY CARPET TILE SCALE: 3" = 1'-0" PARTITION TYPE 31 SCALE: 3" = 1'-0" PARTITION TYPE 01 & 01A SCALE: 3" = 1'-0" PARTITION TYPE 32 SCALE: 3" = 1'-0" PARTITION TYPE 02 SCALE: 3" = 1'-0" PARTITION TYPE 03 SCALE: 3" = 1'-0" CEILING ASSEMBLY B SCALE: 3" = 1'-0" FLOOR ASSEMBLY A C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A1.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set FIRST FLOOR PLANREF016'-8" 3'-0"026'-8" 3'-0" 09 13 6'-8"3'-0"0711 6'-8"3'-0"036'-8" 3'-0" 08056'-8" 2'-6"066'-8" 2'-6" 04 126'-8" 3'-0" 10 6'-8"3'-0"REFREF44" MIN.CLEAR8'-0"8'-0" 35/8" 8'-0"10'-6"9'-5" +/- 35/8" 11'-0"11'-7"35/8"9'-2"10'-2" 48" MIN. CLEAR MODIFY EXISTING WALL WITH ARMORCORE PANEL RELOCATE KEY BOXES TO NEW WALL PROVIDE 6'-0" HIGH CAPPED WALL PROVIDE (3) NEW FCU UNITS 01 31 31 32 32 01 0101 02 01A 01A 03 01A 03 01 32 32 01A 01A HEIGHT OF THIS PARTITION + 8'-0"+/- A.F.F TO MATCH HEIGHT OF WOOD TRIM AT CORRIDOR 100C8 WALLS, TRIM TO MATCH EXISTING HEIGHT OF THIS PARTITION TO UNDERSIDE OF EXISTING DECK (13'-2"+/-) TOP OF THIS PARTITION TO UNDERSIDE OF EXISTING BEAM GC TO EVALUATE CHASE FOR REMOVAL PROVIDE BULLET PROOF PANEL FULL WINDOW HEIGHT EXISTING MAIL BOXES TO REMAIN EXISTING CAST IRON RADIATOR TO REMAIN PROVIDE CARD READER** WITH PUSH BUTTON RELEASE PROVIDE CARD READER** WITH PUSH BUTTON RELEASE PROVIDE CARD READER* PROVIDE CARD READER PROVIDE CARD READER* FOR DOOR 07 PROVIDE CARD READER* PROVIDE BULLET RESISTANT FILM AT UPPER SASH OF EXISTING WINDOW, TYP. @ (3) WINDOWS THIS OFFICE AREA IS A BOX CONSTRUCTED WITHIN THE EXISTING CENTRAL STORES WAREHOUSE, SEE FLOOR ASSEMBLY A AND CEILING ASSEMBLY B ON SHEET A0.2 FOR CEILING AND FLOOR CONSTRUCTION SIM. NOTE: DISPATCH ROOM 106 IS REQUIRED TO BE ENCLOSED IN 1 HOUR FIRE RATED PARTITIONS. GC TO INSPECT EXISTING PARTITIONS TO REMAIN AND MODIFY AS NEEDED TO ENSURE PARTITIONS EXTEND TO UNDERSIDE OF DECK AND MEET FIRE RATING CODE REQUIREMENTS INTERVIEW ROOM 103 WOMEN'S LOCKER ROOM 104 CORRIDOR 100C1 WATER CL. 100T1 WATER CL. 100T2 MEN'S LOCKER ROOM 105 RADIO CAMPUS POLICE 100 OFFICE 101 KITCHENETTE 100K OFFICE 102 OFFICE 130 OFFICE 129 OFFICE 128 CORRIDOR 100C7 CORRIDOR 100C8 WOMEN'S BATHROOM 100T5 MEN'S BATHROOM 100T4 WATER CL. 100T3 JANITORIAL 100J LOADING DOCK 100LD1 CENTRAL STORES 125 BUILDING SERVICES OFFICES 127 BREAK ROOM 100BR CORRIDOR 100C9 OFFICE 127C CLOSETCLOSET OFFICE 127BOFFICE 127A OFFICE 127D VESTIBULE 100V1 DISPATCH 106 SERVER 105 STAIR 100ST1 2 A6.1 2 A6.1 MODIFY EXISTING WALL WITH ARMORCORE PANEL PROVIDE BULLET RESISTANT (LEVEL III) PANEL AT LOWER SASH OF EXISTING WINDOW, TYP. @ (3) WINDOWS N 3 4 6 7 8 1/4" = 1'-0" 1001259 C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A2.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set REFLECTED CEILING PLAN XX XX XX XX X XX X XX X X X X X X X XX X XX RELOCATE HUNG LIGHT FIXTURE TO STRADDLE CLOSET AND CORRIDOR LOW WALL - TO PROVIDE LIGHT FOR BOTH EXISTING LIGHT TO REMAIN PROVIDE NEW LIGHT FIXTURE MOUNTED TO SIDE OF EXISTING BEAM REINSTALL SALVAGED TROFFER LIGHT IN NEW SUSPENDED CEILING EXISTING LIGHT TO REMAIN NEW SAT CEILING AND LIGHTING (3) EXISTING DOWN LIGHTS TO REMAIN ??? (3) NEW DOWN LIGHTS NEW SAT CEILING PROVIDE SOFFIT @ REMOVED WALL, 9'-0"+/-A.F.F. EXISTING LIGHTING & SAT CEILING (9'-1"+/-) TO REMAIN NEW SAT CEILING EXISTING SAT CEILING TO REMAIN, MODIFY FOR NEW PARTITION RELOCATE EXIT SIGN TO NEW DOOR 8'-8" CEILING HEIGHT 8'-8" CEILING HEIGHT 10'-1" CEILING HEIGHT REMOVE LIGHTING, TYP. PROVIDE SOFFIT @ REMOVED WALL, 7'-9"+/- A.F.F. 7'-10" CEILING HEIGHT 7'-10" CEILING HEIGHT 7'-10" CEILING HEIGHT NEW SAT CEILING AND LIGHTING AT (4) OFFICES, TYP. NEW LIGHTING, TYP. EXISTING GWB CEILING (8'-0" A.F.F.) TO REMAIN WALL BELOW 7'-8" CEILING HEIGHT X X REFLECTED CEILING PLAN LEGEND NEW 2X2 LIGHT FIXTURE, RECESSED IN GRID NEW RECESSED DOWN LIGHT 2X2 SUSPENDED ACOUSTIC TILE CEILING (SAT), HUNG GWB CEILING/SOFFIT NEW SURFACE MOUNTED LED STRIP LIGHT FIXTURE HVAC GRILLS EXISTING SPRINKLER HEADS EXIT SIGN WITH DIRECTIONAL ARROW X N 3 4 6 7 8 1/4" = 1'-0" 1001259 C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A6.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set CONSTRUCTION DETAILS 2 A6.1 EXISTING MASONRY WALL EXISTING WOOD TRIM/ CONSTRUCTION TO REMAIN ARMORCORE LEVEL 3 PANEL, NO SEAMS 5/8" GWB WOOD 1/4 ROUND, PAINT 2X2 WOOD BLOCKING 1/2" PLYWOOD, PAINTED DARK GREY ON WINDOW SIDE EXISTING SILL BELOW INTERIOR 1 A6.1 ARMORCORE LEVEL 3 PANEL, NO SEAMS 5/8" GWB WOOD 1/4 ROUND, PAINT 2X4 WOOD BLOCKING 1/2" PLYWOOD, PAINTED DARK GREY ON WINDOW SIDE EXISTING WOOD TRIM/ CONSTRUCTION BEYOND EXISTING WINDOW TO REMAIN WOOD CAP, PAINT EXISTING SILL TO REMAIN EXISTING MASONRY WALL SCALE: 3" = 1'-0"1 PLAN DETAIL @ WINDOW INFILL SCALE: 3" = 1'-0"2 SECTION @ WINDOW INFILL C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A7.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set DETAILED PLANS & INTERIOR ELEVATIONS016'-8" 3'-0"026'-8" 3'-0"036'-8" 3'-0"1'-4"2'-1"4'-0"7 8 9 6 A7.1 3 4 5 2 A7.1 NEW COUNTERFILE CABINETS BELOW MULTIFUNCTION PRINTER MODULAR DISPATCH FURNITURE, & DISPATCH EQUIPMENT - FINAL DESIGN TBD WALL MOUNTED TV MONITOR ADJUSTABLE SHELVING ABOVE DESKS, TYP. BOTH SIDES OF ROOM VESTIBULE 100V1 DISPATCH 106 EXISTING MAP & LIT. RACKS TO REMAIN EXISTING SHELF TO REMAIN EXISTING RADIATOR REMAIN PATCH WALL AT REMOVED PARTITION PROVIDE VINYL BASE, TYP. EXISTING TELEPHONE TO REMAIN ??? EXISTING FIRE ALARM PANEL TO REMAIN REMOVE CARD READER, PATCH WALL PATCH WALL AT REMOVED PARTITION NEW BULLET PROOF, LEVEL 3, SECURITY WINDOW FULL HEIGHT WINDOW INFILL, SEE DETAIL SHEET A6.1 LOWER SASH WINDOW INFILL, SEE DETAIL SHEET A6.1 EXISTING WINDOW TO REMAIN, INSTALL BULLET RESISTANT FILM ON GLAZING PATCH WALL AT REMOVED PARTITION PATCH WALL AT REMOVED RADIATOR PIPE, TYP. PROVIDE ADJUSTABLE SHELVING NEW VINYL BASE THROUGHOUT, TYP. LOWER SASH WINDOW INFILL, SEE DETAIL SHEET A6.1 EXISTING WINDOW TO REMAIN, INSTALL BULLET RESISTANT FILM ON GLAZING PROVIDE ADJUSTABLE SHELVING NEW COUNTER 2'-6"NEW BULLET RESISTANT (LEVEL 3) & 1 HR. FIRE RATED, SECURITY WINDOW PATCH WALL AT REMOVED PARTITION PROVIDE POWER & DATA FOR NEW TV PATCH WALL BEYOND AT REMOVED RADIATOR PIPE NEW COUNTER 24 HOUR CLOCK SCALE: 1/2" = 1'-0"1 DISPATCH & VESTIBULE DETAILED PLAN SCALE: 1/2" = 1'-0"3 VESTIBULE 100V1 EAST SCALE: 1/2" = 1'-0"4 VESTIBULE 100V1 SOUTH SCALE: 1/2" = 1'-0"2 VESTIBULE 100V1 NORTH SCALE: 1/2" = 1'-0"5 VESTIBULE 100V1 WEST SCALE: 1/2" = 1'-0"9 DISPATCH 106 WEST SCALE: 1/2" = 1'-0"8 DISPATCH 106 SOUTH SCALE: 1/2" = 1'-0"6 DISPATCH 106 NORTH SCALE: 1/2" = 1'-0"7 DISPATCH 106 EAST C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A7.2 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set DETAILED PLANS & INTERIOR ELEVATIONS2'-10"OPEN SHELF FOR OWNER FURNISHED MICROWAVE, PROVIDE ELECTRICAL RECEPTACLE ADJUSTABLE SHELVING WITH INTEGRAL DISH DRYING RACK PATCH WALL AT REMOVED PARTITION COUNTERTOP OPEN TO CORRIDOR REFRIGERATOR PROVIDE VINYL WALL BASE PATCH WALL AT REMOVED PARTITION PROVIDE CARD READER REF026'-8" 3'-0"036'-8" 3'-0" 04 . 2 3 4 A7.2 WALL MOUNTED TV MONITOR KITCHENETTE 100K SEPARATE FAUCET FOR WATER FILTER SCALE: 1/2" = 1'-0"2 KITCHENETTE 100K SOUTH SCALE: 1/2" = 1'-0"4 KITCHENETTE 100K NORTH SCALE: 1/2" = 1'-0"3 KITCHENETTE 100K WEST SCALE: 1/2" = 1'-0"1 KITCHENETTE DETAILED PLAN C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A8.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set FURNITURE PLANREFREFREF36"24"36"32" MIN. CLEAR OWNER TO RELOCATE PRINTER OWNER TO RELOCATE FILE CABINETS FROM CAMPUS POLICE 100 2X2 SERVER RACK NEW EVIDENCE LOCKER PROVIDE SHADES AT (3) WINDOWS MODULAR DISPATCH FURNITURE, & DISPATCH EQUIPMENT, FINAL DESIGN TBD COPY/ PRINTFILE CABS.COPY/ PRINT INTERVIEW ROOM 103 WOMEN'S LOCKER ROOM 104 CORRIDOR 100C1 WATER CL. 100T1 WATER CL. 100T2 MEN'S LOCKER ROOM 105 RADIO CAMPUS POLICE 100 OFFICE 101 KITCHENETTE 100K OFFICE 102 OFFICE 130 OFFICE 129 OFFICE 128 CORRIDOR 100C7 CORRIDOR 100C8 WOMEN'S BATHROOM 100T5 MEN'S BATHROOM 100T4 WATER CL. 100T3 JANITORIAL 100J LOADING DOCK 100LD1 CENTRAL STORES 125 BUILDING SERVICES OFFICES 127 BREAK ROOM 100BR CORRIDOR 100C9 OFFICE 127C CLOSETCLOSET OFFICE 127BOFFICE 127A OFFICE 127D VESTIBULE 100V1 DISPATCH 106 SERVER 105 STAIR 100ST1 N 3 4 6 7 8 1/4" = 1'-0" 1001259 C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. A9.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set DOOR SCHEDULE & DETAILS DOOR SCHEDULE NO. 01 02 03 04 05 06 07 08 09 10 11 12 13 ROOM NAME VESTIBULE VESTIBULE DISPATCH SERVER CORRIDOR CORRIDOR BUILDING SERVICES OFFICES CORRIDOR STAIR OFFICE OFFICE OFFICE BREAK ROOM RM. NUMBER 100V1 100V1 106 105 100C7 100C8 127 100C1 100ST1 127B 127C 127D 100BR ELEV. A B C C C C C ETR ETR D D D D WIDTH 3'-0" 3'-0" 3'-0" 3'-0" 2'-6" 2'-6" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" HEIGHT 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" FRAME MAT. BP HM BP HM HM ETR HM HM ETR ETR ETR HM HM HM HM PANEL CONST. SC SC SC ETR SC SC ETR ETR ETR SC SC SC ETR FINISH PT PT PT PT PT PT PT ETR ETR PT PT PT PT GLASS DG -- -- -- -- -- -- -- ETR 1/2 LITE 1/2 LITE 1/2 LITE ETR FIRE RATING -- -- 1 HOUR -- -- -- -- -- -- -- -- -- -- HARDWARE SET HDWR. SET SUMMARY NEW CARD READER YES** YES YES YES YES** NOTES **PROVIDE CARD READER WITH PUSH BUTTON RELEASE INSTALL SALVAGED DOOR INSTALL SALVAGED DOOR CARD ACCESS ADDED TO EXISTING DOOR **PROVIDE CARD READER WITH PUSH BUTTON RELEASE, AND PROVIDE NEW MECHANICAL OPERATOR PROVIDE SHADE AT LITE PROVIDE SHADE AT LITE PROVIDE SHADE AT LITE INSTALL SALVAGED DOOR PEEP HOLE EXISTING TRANSOM TO REMAIN, INSTALL BULLET RESISTANT FILM ON GLAZING BA C D FG DOOR TYPES C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. M1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set HVAC MODIFICATION PLANREFREFREF (3) EXISTING FCU UNITS TO REMAIN (4) NEW FCU UNITS REINSTATE AIR HANDLER UNIT FOR THIS AREA PROVIDE NEW ERV FOR THIS AREA EXISTING HVAC GRILLS TO REMAIN, TYP. EXISTING HVAC GRILL TO REMAIN ?? THESE RADIATORS TO BE REMOVED 2019-05-03 A9.1 Door Dwg Notes.docx {Note: When PDF’ing - use custom paper size 5”x36”} MECHANICAL GENERAL NOTES 1. RECONFIGURATION OF HVAC SUPPLY AND RETURN SHOWN ON DRAWINGS TO BE DONE AS PART OF A DESIGN BUILD PROCESS BY THE HVAC CONTRACTOR. PROVIDE SUBMITTAL FOR REVIEW PRIOR TO STARTING WORK. 2. HVAC EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT APPROXIMATE LOCATIONS OF EQUIPMENT TO THE BEST OF OUR KNOWLEDGE AND ARE FOR REFRENCE ONLY. ALL EXISTING CONDITIONS TO BE VERIFED IN FIELD. NOTIFY OWNER OF DISCREPENCIES. HVAC PLAN LEGEND HVAC RETURN GRILL EXISTING SPRINKLER HEADS HVAC SUPPLY GRILL N 3 4 6 7 8 1/4" = 1'-0" 1001259 C&H Architects© 2020 Coldham & Hartman Architects This drawing is not intended nor shall it be used for construction unless the signed seal of a design professional is affixed. D1.1 File: 19-02-08 SC Campus Police.pln Print Date: 1/13/20C&H Project #: Scale: Drawn By: Checked By: 19-02.08 SW TRCHSmith CollegeCampus PoliceRenovation126 West St, Northampton, MA13 January 2020 Permit Set FIRST FLOOR DEMOLITION PLANREFREF REF REFREMOVE STORE FRONT GLAZING & DOOR REMOVE WINDOW & REFRAME OPENING FOR NEW WINDOW REMOVE RADIATOR REMOVE RADIATOR REMOVE BUILT IN DESKS, CABINETS, SHELVING AND ANY OTHER MISCELLANEOUS ITEMS ATTACHED TO THE WALLS, TYP. @ THREE ROOMS REMOVE DOOR PANEL ONLY, DOOR FRAME TO REMAIN, INSTALL DOOR PANEL AT DOOR #13 REMOVE AND SALVAGE KEY BOXES FOR RELOCATION OWNER TO REMOVE PARTITION WALLS OWNER TO RELOCATE REFRIGERATOR & OFFICE EQUIPMENT REMOVE FCU UNIT OWNER TO RELOCATE STORAGE SHELVING PROVIDE OPENING FOR NEW DOOR REMOVE DESK OWNER TO RELOCATE FILE CABINETS REMOVE RADIATOR RELOCATE PRINTER REMOVE RADIATOR EXISTING RADIATOR TO REMAIN OWNER TO RELOCATE REFRIGERATOR & MICROWAVEREPLACE DOOR/ SIDELITE, EXISTING TRANSOME WINDOW TO REMAIN REMOVE DOOR PANEL ONLY, DOOR FRAME TO REMAIN, INSTALL DOOR PANEL AT DOOR #07 SALVAGE DOOR PANEL & FRAME, INSTALL AT DOOR #04 N 3 4 6 7 8 1/4" = 1'-0" 1001259