Loading...
Olander Extension_Bid Plans_03.11.20_finalLandscape ArchitectureLand SurveyingPlanningCivil EngineeringPrepared by:Sheet IndexDatePrepared for:OLANDER DRIVE EXTENSIONCity of NorthamptonOffice of Planning and Sustainability210 Main StreetNorthampton, MA 01060TCB Revitalization Services, LLC.c/o The Community Builders31 Trumbull RoadNorthampton, MA 01060OwnerHospital Hill Development, LLCc/o MA Development Finance Agency99 High StreetBoston, MA 01469Location PlanScale 1"=250'Village HillNORTHAMPTON, MASSACHUSETTSLocation PlanScale 1"=1200'MEMORIAL PARK4 Allen Place NorthamptonMassachusetts 01060www.berkshiredesign.comBerkshireGroupDesignMARCH 11, 2020 BID DOCUMENTSLOT 13AOLANDER DR. EXT.MULTI-USEPATHCONNECTIONC-1OVERALL PLANC-2ROAD SITE PLANC-3 GRADING AND UTILITY PLANSC-4MEMORIAL PARK SITE PLANC-5MULTI-USE PATH CONNECTIONC-6.1-6.2 DETAILSWF-1.0WATER FEATURE PLAN LAYOUTWF-2.0WATER FEATURE MECHANICAL DETAILSWF-3.0WATER FEATURE PUMP SYSTEM DETAILSOlander Drive at Ford CrossingNorthampton, Massachusetts GGGGGG//////Lot 13-A 41.0 Acres 1784204.8 Sq. Feet ± Ford C r o s si n g Olander Dr ive231231232232232 231 231231232233234229228216217218219221222223224226227228229231232233 2 3 4 2 3 6 2 3 7 2 3 8 2 3 9 239238237236234 233 232 232 233 234 236 237 2 3 2 2 3 1 22 9 22 8 221 2182172192 1 6 231 22 7 22 6 228 2 2 1 2 2 3 2 2 2 22 4 2 1 6 2 1 9 2 1 7 2 1 8 21 1 2 1 2 2132 1 4 2 0 6 2 0 7208209 2012 0 2 2 0 3 2 0 4 196 197 198 19 9 193 194 192 193 1 9 1 1 9 8 1 9 9 201203204202203202 2012042072062082092282272292262222232212242162 1 9 2172182142 1 1 2 1 2 2132262292 2 7 2 2 8 22422122222321621221321421120920820720620120220320419919919719819623 0 2 3 0 2302252202152102052002302302302352302 3 5 240 235 235230 2202152252202302252202 1 5 210210205205200 22 5 2 2 0 2 1 5 21 0 2 0 5 20 0 195 190 185 180 175 170 165 200 19 5 190 2 0 0 205210215220225180 185 190 220215210205215210206 20720820921121220120220420320920820720621221121321020520021020521520020020020020019619619819619819819020020220420620019820221020521522023 0 222 2232 2 4 22 5 2 2 6 227MEMORIAL PARK OLANDER DRIVE EXTENSION MULTI-USE PATH CONNECTION PROPOSED NORTH COMMONS (NOT IN CONTRACT) MEADOW RUN (NOT IN CONTRACT) COHOUSING (NOT IN CONTRACT) PECOY HOUSING (NOT IN CONTRACT) Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-1 MARCH 11, 2020 1" = 50' LC CC/JS OVERALL PLAN 0 1005025 150 BID DOCUMENTS GGGGGGGGGGGGGGG231232233234236237232231229228221218 217 219216 221223222216219217218214228 227 229226222223224 230 230230 235220 215 230225 220215220 225 230222223224225226227 EX. TREES TO REMAIN. PROVIDE TREE PROTECTION FENCE SEE DETAIL 5/C-6.2 CONFIRM EXTENT OF TREE PROTECTION IN THE FIELD WITH TREE WARDEN. PROVIDE AIR SPADING WITHIN CONSTRUCTION ZONE (ALT #2)./STRAW WATTLE AND SILT FENCE AT DOWN-SLOPE LIMIT OF GRADING WORK (TYP.) SEE DETAIL 2/C-6.2 STRAW WATTLE AT DOWN-SLOPE LIMIT OF WORK (TYP.) SEE DETAIL 3/C-6.2 STABILIZED CONSTRUCTION ENTRANCE SEE DETAIL 1/C-6.2 RESTORE ALL DISTURBED AREAS WITH LOAM AND SEED (WEST SIDE OF ROAD CONSTRUCTION) RESTORE DISTURBED AREAS WITH LOAM AND NEW ENGLAND CONSERVATION/WILDLIFE MIX. SEE PLANTING NOTES. (EAST SIDE OF ROAD CONSTRUCTION). BEGIN SIDEWALK AND GRANITE CURB INSTALLATION MATCH EXISTING SIDEWALK AND CURB ELEVATIONS. LIMIT OF SIDEWALK CONSTRUCTION END CURB AND SIDEWALK CONSTRUCTION END WALL CONSTRUCTION. CONSTRUCT CORNER TO ALLOW FOR FUTURE EXTENSION OF THE WALL. CURB OPENING SEE DETAIL 4/C-6.1 BEGIN ROAD CONSTRUCTION UP TO AND INCLUDING BINDER. END ROADWAY CONSTRUCTION PROPOSED GRANITE CURB- SEE DETAIL 3/C-6.1 PROPOSED 5' CONCRETE SIDEWALK - SEE DETAIL 2/C-6.1 PROPOSED ROAD (BINDER COURSE ONLY) - SEE DETAIL 1/C-6.1 PROPOSED WALL AND GUARD RAIL SEE DETAILS 5,6/C-6.1 END GUARD RAIL CONSTRUCTION PROPOSED WALL (NOT PART OF BASE BID) PROPOSED CURB (NOT PART OF BASE BID) PROPOSED FUTURE SIDEWALK (N.I.C.) STREET TREE PLANTING (TYP) - SEE DETAIL 4/C-6.2 BEGIN WALL CONSTRUCTION BEGIN GUARD RAIL CONSTRUCTION RELOCATE ROCK PILE 4 LS 2 UA 1 PT 3 QP 2 QP 1 SJ 1 SJ2 NS Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-2 MARCH 11, 2020 1" = 20' LC CC/JS ROAD SITE PLAN 0 402010 60 1. DO NOT SCALE DRAWINGS FOR QUANTITY TAKE-OFFS OR CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY. IF DIMENSIONS ARE INCOMPLETE, CONTACT THE BERKSHIRE DESIGN GROUP, INC. FOR CLARIFICATION. 2. ALL LINES OR POINTS ARE PERPENDICULAR OR PARALLEL TO LINES FROM WHICH THEY ARE MEASURED UNLESS OTHERWISE NOTED. 3. THE CONTRACTOR SHALL VERIFY ALL LAYOUT, DIMENSIONS, GRADES, AND INVERTS PRIOR TO CONSTRUCTION; REPORT ANY AND ALL DISCREPANCIES TO THE LANDSCAPE ARCHITECT. ALL DISCREPANCIES SHALL BE RESOLVED IN WRITING PRIOR TO BEGINNING WORK. 4. ALL AREAS DISTURBED FROM CONSTRUCTION ACTIVITY TO BE RAKED, SMOOTHED, FERTILIZED AND SEEDED WITH PERENNIAL TURFGRASSES UNLESS OTHERWISE NOTED. 5. ALL NEW WALKS AND SURFACES TO MEET EXISTING WALKS AND SURFACES WITH SMOOTH, CONTINUOUS LINE AND GRADE. 6. THE CONTRACTOR SHALL NOT INSTALL CONCRETE DURING ADVERSE WEATHER CONDITIONS (RAIN, SLEET, ETC.) UNLESS OTHERWISE DIRECTED BY THE LANDSCAPE ARCHITECT. DEMOLITION NOTES 1. ALL MATERIALS, UTILITY, AND CONSTRUCTION METHODS TO FOLLOW NORTHAMPTON DPW SUBDIVISION REQUIREMENTS. 2. THIS PLAN IS PREPARED AS AN ENGINEERING DESIGN AND IS NOT INTENDED TO BE USED FOR THE DETERMINATION OF PROPERTY LINES. GENERAL NOTES BID DOCUMENTS EROSION CONTROL NOTES 1.THE CONTRACTOR SHALL INSTALL EROSION CONTROL DEVICES AS NECESSARY TO PREVENT EROSION WITHIN THE SITE AND MIGRATION OF SEDIMENT OUT OF THE SITE, OR AS DIRECTED BY THE ENGINEER. ALL DEVICES SHALL COMPLY WITH THE MASSACHUSETTS EROSION AND SEDIMENT CONTROL GUIDELINES, CURRENT VERSION. 2.THE PROPOSED PROJECT IS SUBJECT TO THE CONDITIONS OF A NORTHAMPTON STORMWATER PERMIT. THE CONTRACTOR SHALL COMPLY WITH ALL CONDITIONS OF THE STORMWATER PERMIT. 3.NATURAL VEGETATION SHALL BE RETAINED WHEREVER FEASIBLE UP TO THE SCHEDULED START OF CONSTRUCTION ACTIVITY IN THE AREA. WHERE POSSIBLE, CLEARING SHALL IMMEDIATELY PRECEDE CONSTRUCTION ACTIVITY. 4.ALL VEHICLES ENTERING AND EXITING THE SITE SHALL BE REQUIRED TO CROSS A STABILIZED CONSTRUCTION ENTRANCE TO PREVENT TRACKING OF SEDIMENT ONTO CAMPUS OR PUBLIC ROADWAYS. IF SEDIMENT IS FOUND ON ROADWAYS, THE SEDIMENT SHALL BE REMOVED IMMEDIATELY. 5.THE CONTRACTOR SHALL INSTALL SILT FENCE AND STRAW WATTLE ALONG ALL DOWN-SLOPE SITE LIMITS TO PREVENT THE MIGRATION OF SEDIMENT OFF-SITE. 6.ALL SEDIMENT STOCKPILES SHALL BE SURROUNDED BY A CONTINUOUS SILT FENCE. IF THE STOCKPILE WILL REMAIN UNUSED FOR MORE THAN 14 DAYS, THE STOCKPILE SHALL BE STABILIZED BY SEEDING. 7.ALL DEWATERING DISCHARGES SHALL BE DIRECTED TO A DEWATERING SEDIMENT TRAP. 8.ALL DISTURBED SLOPES GREATER THAN 3H:1V SHALL BE PROTECTED FROM EROSION BY THE INSTALLATION OF BIO-DEGRADABLE OR PHOTO-DEGRADABLE EROSION CONTROL BLANKETS. EROSION CONTROL BLANKETS SHALL BE USED IN OTHER LOCATIONS AS DIRECTED BY THE ENGINEER, IF OTHER MEANS OF EROSION CONTROL ARE FOUND TO BE INADEQUATE. 9.THE CONTRACTOR SHALL INSPECT ALL INSTALLED EROSION CONTROL DEVICES A MINIMUM OF ONCE PER WEEK AND AFTER EACH STORM. IF ANY DEVICE IS FOUND TO BE DAMAGED, THE CONTRACTOR SHALL REPAIR IT IMMEDIATELY. IF SEDIMENT IS FOUND TO FILL MORE THAN HALF THE HEIGHT OF THE DEVICE, THE SEDIMENT SHALL BE REMOVED OR THE DEVICE REPLACED. 10.THE CONTRACTOR SHALL MAINTAIN A STOCKPILE OF EXTRA EROSION CONTROL MATERIALS ON SITE AT ALL TIMES. 11.THE CONTRACTOR SHALL IMPLEMENT SPILL-PREVENTION PROCEDURES AND MAINTAIN A SPILL PREVENTION AND CLEANUP PLAN FOR THE SITE. ALL MATERIALS THAT ARE CAPABLE OF SPILLING, LEAKING, DISSOLVING OR OTHERWISE POLLUTING STORMWATER RUNOFF SHALL BE COVERED WHILE STORED AT THE SITE. 12.ALL MATERIALS THAT ARE CAPABLE OF SPILLING, LEAKING, DISSOLVING OR OTHERWISE POLLUTING STORMWATER RUNOFF SHALL BE COVERED WHILE STORED AT THE SITE. 13.ALL SEDIMENT REMOVED FROM THE SITE SHALL BE HANDLED IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. 14.ALL TEMPORARY EROSION CONTROLS SHALL BE REMOVED FROM THE SITE PRIOR TO THE COMPLETION OF THE WORK, EXCEPT WHERE DEGRADABLE MATERIALS ARE TO REMAIN IN-PLACE PERMANENTLY. UTILITY NOTES 1.ALL SANITARY LINE INVERTS ARE SHOWN FROM CENTERLINE TO CENTERLINE OF SEWER MANHOLE. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A MINIMUM 0.1' DROP FROM INLET INVERT TO OUTLET INVERT (2.0% CHANNEL) UNLESS OTHERWISE NOTED. 2.WATER MAINS AND SERVICES SHALL HAVE A MINIMUM OF 5' OF COVER. DEPTH OF COVER MAY BE VARIED TO ACCOMMODATE CROSSING OF SANITARY SEWERS AND STORM DRAINS. IN ALL CASES, THE MAXIMUM COVER SHALL BE 7.5'. 3. WATER MAINS AND SERVICES SHALL HAVE A MINIMUM OF 2' HORIZONTAL SEPARATION FROM THE OUTSIDE WALL OF ANY CATCH BASIN STRUCTURE. 4.WATER MAINS SHALL HAVE THRUST BLOCKS CONSTRUCTED AT ALL ANGLES, BENDS, BRANCHES, PLUGS AND WHEREVER ELSE IS NECESSARY TO PREVENT DISRUPTION OF PROPER FUNCTIONING OF THE LINE. 5.CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS FOR THE ALL UTILITY SYSTEM INCLUDING, AT A MINIMUM, SWING TIES TO FIXED OBJECTS FOR ALL SANITARY AND DRAINAGE MANHOLES, DRAINAGE STRUCTURES, CLEANOUTS, WATER MAIN FITTINGS, GATE VALVES, AND ELECTRICAL/COMMUNICATIONS STRUCTURES/MANHOLES/PULL BOXES. AS BUILT DRAWINGS SHALL BE PROVIDED AS CLEAN READABLE MARK-UPS OF THE DESIGN PLANS. 6.ALL STUBS TO BE CAPPED AND MARKED WITH A 4X4 POST. GRADING 1. ALL SIDEWALKS/WALKWAYS SHALL CONFORM TO THE MASSACHUSETTS ARCHITECTURAL ACCESS BOARD'S (AAB) REQUIREMENTS. TYPICAL SIDEWALK/WALKWAY CROSS-SLOPE IS 1.0% MINIMUM, 2.0% MAXIMUM. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO THE CONSTRUCTION STANDARDS AND SPECIFICATIONS OF THE CITY OF NORTHAMPTON AND THE MASSACHUSETTS DEPARTMENT OF TRANSPORTATION. 3. ALL NEW OR ADJUSTED MANHOLES, GAS GATES, WATER GATES AND WATER SERVICES TO BE FLUSH WITH FINISHED GRADE. ALL NEW OR ADJUSTED CATCH BASIN RIMS SHALL BE SET 1/2" BELOW FINISHED GRADE. 1. ALL NURSERY STOCK SHALL COMPLY WITH THE LATEST STANDARDS OF THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION WITH REGARD TO GRADING AND QUALITY. 2. ALL PLANTS SHALL CONFORM TO THE MEASUREMENTS SPECIFIED, EXCEPT THAT PLANTS LARGER THAN THOSE SPECIFIED MAY BE USED IF APPROVED BY THE LANDSCAPE ARCHITECT. 3. ALL PLANTS SHALL BE NURSERY GROWN IN ACCORDANCE WITH GOOD HORTICULTURAL PRACTICES AND SHALL BE GROWN UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE PROJECT LOCALITY FOR AT LEAST TWO YEARS. 4. BALLED AND BURLAPPED PLANTS (B&B) SHALL BE MOVED WITH THE ROOT SYSTEM AS SOLID UNITS; ROOT BALLS SHALL BE FIRMLY WRAPPED WITH BURLAP. CONTAINER GROWN PLANTS SHALL NOT BE REMOVED FROM CONTAINER PRIOR TO THE TIME OF INSTALLATION; ROOT SYSTEM SHALL BE FIRMLY SET IN CONTAINER. 5. PLANTING SOIL MIX SHALL CONSIST OF SEVEN (7) PARTS LOAM AND ONE (1) PART PEAT MOSS BY VOLUME, WITH A PH VALUE OF 5.0 TO 6.0. 6. ALL TREES AND SHRUBS TO RECEIVE TWO (2) MYCORRHIZAE/Terra Sorb FERTILIZER PACKETS SUCH Roots Tree Saver AND AS SHOWN IN DETAILS. 7. PLANTING BEDS TO RECEIVE 2" DEPTH OF BARK MULCH. 8. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR ONE FULL GROWING SEASON (ONE YEAR) AFTER INSTALLATION. 9. ANY PLANT MATERIAL WHICH DIES, TURNS BROWN OR UNEXPECTEDLY DEFOLIATES PRIOR TO ACCEPTANCE OF WORK SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUALITY, SIZE AND MEETING ALL PLANTING SPECIFICATIONS. 10. PLANTING LAYOUT SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. New England Conservation/Wildlife Mix APPLICATION RATE: 25lbs/acre | 1750 sq ft/lb SPECIES: Virginia Wild Rye (Elymus virginicus), Little Bluestem (Schizachyrium scoparium), Big Bluestem (Andropogon gerardii), Red Fescue (Festuca rubra), Switch Grass (Panicum virgatum), Partridge Pea (Chamaecrista fasciculata), Panicled leaf Tick Trefoil (Desmodium paniculatum), Indian Grass (Sorghastrum nutans), Blue Vervain (Verbena hastata), Butterfly Milkweed (Asclepias tuberosa), Black Eyed Susan (Rudbeckia hirta), Common Sneezeweed (Helenium autunale), Heath Aster (Asterpilosus/Symphyotrichum pilosum), Early Goldenrod (Solidago juncea), Upland Bentgrass (Agrostis perennans). 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR A THOROUGH SITE EXAMINATION TO DETERMINE THE EXTENT OF DEMOLITION NECESSARY TO PREPARE THE SITE FOR CONSTRUCTION AND SHALL VERIFY ALL ITEMS TO BE DEMOLISHED OR SALVAGED WITH THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING WORK. 2. CARE SHALL BE TAKEN NOT TO DAMAGE ANY ITEMS DESIGNATED TO REMAIN; REPAIR OR REPLACEMENT OF DAMAGED ITEMS DESIGNATED TO REMAIN SHALL BE AT THE CONTRACTORS' EXPENSE. 3. DISPOSAL OF PROPERTY DESIGNATED TO BE REMOVED SHALL BE AT THE DIRECTION OF THE LANDSCAPE ARCHITECT OR OWNER, AND SHALL CONFORM TO ALL APPLICABLE LAWS AND REGULATIONS. ALL SALVAGABLE MATERIAL SHALL BE DELIVERED BY THE CONTRACTOR TO STORAGE AREAS DESIGNATED BY THE LANDSCAPE ARCHITECT. CONTRACTOR SHALL REMOVE ALL EXISTING UNSUITABLE MATERIALS FROM THE SITE. 4. THE CONTRACTOR SHALL PROTECT EXISTING TREES TO REMAIN AS DESIGNATED ON THE PLANS AND IN ACCORDANCE WITH THE NORTHAMPTON TREE PROTECTION GUIDELINES. 5. ALL TOPSOIL SHALL BE STRIPPED FROM GRASS AREAS TO BE REMOVED AND STOCKPILED IN A DESIGNATED AREA. THE CONTRACTOR IS RESPONSIBLE FOR ALL TOPSOIL TESTING AND AMENDMENTS AS NEEDED TO MEET THE SPECIFICATIONS. 6. THE CONTRACTOR MAY USE TEMPORARY FENCING TO CONTROL THE SITE DURING CONSTRUCTION. PRIOR TO THE FINALIZATION OF THE PROJECT, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY FENCING AND BARRICADES. 7. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY BASED ON AVAILABLE DATA AND ALL UTILITIES MAY NOT BE SHOWN. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL CONTACT DIG SAFE AT 1-800-322-4844 TO REQUEST UTILITIES TO BE MARKED ON THE GROUND. EXISTING UTILITIES WITHIN OLANDER DRIVE ARE PRIVATE AND MAY NOT BE LOCATED BY DIG SAFE OR NORTHAMPTON DPW. ENGINEER WILL PROVIDE CONTRACTOR WITH AS-BUILT DRAWINGS OF THE INSTALLED UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS/HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES. 8. ALL BOUNDARY MONUMENTS SHALL BE PROTECTED AND/OR PRESERVED DURING DEMOLITION AND CONSTRUCTION. SHOULD ANY BOUNDARY MONUMENT BE DESTROYED AND/OR ALTERED AS A RESULT OF DEMOLITION AND CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE PARTY CAUSING THE DAMAGE TO OBTAIN THE SERVICES OF A PROFESSIONAL LAND SURVEYOR TO REPLACE AND RESET SAID MONUMENT. 9. PRIOR TO THE START OF ANY DEMOLITION WORK, THE CONTRACTOR SHALL ARRANGE AN INSPECTION OF ALL TREE PROTECTION MEASURES WITH THE CITY TREE WARDEN. LAYOUT NOTES PLANTING NOTES Plant List NS Key Qty 2 Botanical Name Nyssa sylvatica Common Name Black Gum Size 2.5"-3" cal. PT QP 1 5 Pinus thunbergiana Quercus palustris Japanese Black Pine Pin Oak #10 pot 2.5"-3" cal. SJ UA 2 2 Styphnolobium japonicum Ulmus americana 'Valley Forge' Scholar Tree Valley Forge Elm 2.5"-3" cal. 2.5"-3" cal. LS 4 Liquidambar styraciflua American Sweetgum 2.5"-3" cal. Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-3 MARCH 11, 2020 1" = 20' LC CC/JS GRADING AND UTILITY PLAN BID DOCUMENTS 0 402010 60 UTILITIES PLAN GRADING PLAND TEC222.8'231232233234236237232231229228221218 217 219216 228 227 229226222223224 230 230230 235220 215 230225220 225 230222223224225226227 TECTC 229.42 BC 228.92 TC 229.27 BC 228.77 TC 229.39 BC 228.89 +HP TOW 229.5 BOW 224.0 TOW 229.5 BOW 229.0 TOW 229.5 BOW 224.0 TOW 229.5 BOW 222.0 BC 229.11 TC 229.61 228227226225224223222TC 229.42 BC 228.92 229.25229.00229.40 229.55 EX. TREES TO REMAIN. PROVIDE TREE PROTECTION FENCE SEE DETAIL 5/C-6.2 CONFIRM EXTENT OF TREE PROTECTION IN THE FIELD WITH TREE WARDEN. PROVIDE AIR SPADING WITHIN CONSTRUCTION ZONE (ALT #2)./GRADE BACK TO EXISTING GRADE END OF BINDER PAVEMENT AND GRANITE CURB INSTALL EROSION CONTROL BLANKET (3,500 SF±) RELOCATE THE ROCK PILE - SEE SHEET C-2 GRADING AND BOTTOM OF CURB ELEVATIONS SHOWN REPRESENT FINAL PAVEMENT ELEVATIONS INCLUDING SURFACE COURSE. CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING TO TOP OF BINDER COURSE ELEVATION.GGGGGGGGGGGGGGGG 2" SMH Rim: 2 3 0. 4 5' 220.1'220.1'222.8'231232233234236237232231229228221218 217 219216 223228 227 229226222223224 230 230230 235220 215 230225220 225 230222223224225226227 E E E E T T T TEE TT6" D.I.15" H D P E @ 1 %12" HDPE @ 1%8" PVC @ 1%BEGIN INSTALLATION OF 4" PVC SLEEVE FOR FUTURE GAS INSTALLATION 12" HDPE @ 2.0% (MIN.) NYLOPLAST MANHOLE RIM 230.00 INV N 224.65 INV W 224.65 INV OUT 223.65 PROVIDE CAPS FOR W AND N SPURS FOR FUTURE CONSTRUCTION CATCH BASIN CB#5 RIM 228.65 INV 225.65 CATCH BASIN CB#6 RIM 228.65 INV 225.65 STUBBED GAS CONDUIT FOR FUTURE USE (EXTEND 10' BEYOND SIDEWALK) INSTALL CLEANOUT TO MARK END OF CONDUIT SEE DETAIL 10/C-6.1 STUB OUT SANITARY SEWER 8" PVC @ 1.0% (EXTEND 10' BEYOND SIDEWALK) CAP AND MARK LOCATION WITH A 4X4 POST. EXTEND WATER MAIN TO BACK OF SIDEWALK FOR FUTURE CONNECTION. CAP AND MARK LOCATION WITH A 4X4 POST. EXTEND DRAINAGE TO BACK OF CURB FOR FUTURE CONNECTION. CAP AND MARK LOCATION WITH A 4X4 POST. INSTALL 8" CUT-IN TEE AND 40 ' 8" DI WATER SERVICE STUB. CAP AND MARK END WITH 4X4 POST.8" DI8" GATE VALVE 45 ° BEND 8X6 DI REDUCER 8X8X8 TEE 8" DI (EX.) 225.0± 12" DRAIN 223.25 22.5° BEND 8.5' WATER AND SEWER (EXISTING) 12" HDPE SPUR TO MEADOW RUN (EXISTING) DRAIN MANHOLE DMH#8 (EXISTING) RIM 229.97 INV(W) 223.00 INV(NW) 220.90 INV (S) 222.92(EXISTING) INV (OUT) 220.77 (EXISTING) DRAIN MANHOLE DMH #7 (EXISTING) RIM 228.9 INV(W) 225.00 INV(SW) 225.00 INV (S) 225.00 INV(OUT) 224.90 SANITARY SEWER MANHOLE (EXISTING) RIM 229.9 INV 223.25 EXISTI N G P A T H EXISTING BEECH TREE TO BE PROTECTED CLAD THE TRUNK OF THE TREE WITH 2X4 LUMBER (8'LONG MIN.) SECURED WITH WIRE. BURLAP SHALL BE PLACED BETWEEN CLADDING AND TRUNK TO PREVENT DAMAGE.WWWWWE ET91 OLANDER DR. OLANDER DR. DEPTH OF FOUNTAIN WALL TO BE VERIFIED IN FIELD. PROPOSED GRADES AROUND FOUNTAIN MAY CHANGE BASED ON FIELD CONDITIONS. VERIFY WITH LANDSCAPE ARCHITECT. PROPOSED 4' WIDE ASPHALT PATH. SEE DETAIL 7/C-6.1 CONNECTION TO EXISTING PATH MATCH EXISTING GRADE INSTALL TREE PROTECTION FENCING. SEE DETAIL 4/C6.2. CONFIRM EXTENT OF TREE PROTECTION IN THE FIELD WITH NORTHAMPTON TREE WARDEN. INSTALL SILT FENCE WITH STRAW WATTLE AT BASE OF SLOPE. SEE DETAIL 2/C-6.2 INSTALL STRAW WATTLE AT BASE OF SLOPE. SEE DETAIL 3/C-6.2 PROPOSED 4' WIDE CONCRETE SIDEWALK SEE DETAIL 2/C-6.1 MAX 2% SLOPE IN ANY DIRECTION ON CURVE MAX 2% SLOPE IN ANY DIRECTION ON CURVE EXISTING FOUNTAIN BASIN TO REMAIN. FOUNTAIN EQUIPMENT . SEE SHEETS WF-1.0-3.0 WATER SERVICE BY CITY OF NORTHAMPTON (SEE WF-1.0) INSTALL (2) 3" PVC CONDUIT TO TRANSFORMER FOR FOUNTAIN POWER SUPPLY; 240 VOLT, 100-AMP SERVICE (SEE DETAIL WF-2.0/4) INSTALL EROSION CONTROL FABRIC ON ALL SLOPES AS SHOWN - 3,700 SF. RESTORE CONCRETE SIDEWALK AND GRANITE CURB TO MATCH EXISTING. SAWCUT SIDEWALK AT JOINTS AND REPLACE FULL PANELS . (DETAIL 2/C-6.1) RESET GRANITE CURB (DETAIL 3/C-6.1)EXISTING GRADE IN THIS AREA HASCHANGED SINCE THE SURVEY. PROPOSEDGRADING SHALL MATCH EXISTING GRADESAT PROPERTY LINE. PROPOSED GRADINGSHOWN APPROXIMATES CURRENT GRADES.INSTALL (2) 3" PVC CONDUITS WITHIN PAVERS ACROSS WALKS AND DRIVEWAY. PAVERS TO BE REPLACED TO MATCH EXISTING CONDITION. CONNECT TO EXISTING TRANSFORMER. IF TRENCH EXCAVATION WIDTH ACROSS DRIVEWAY EXCEEDS WIDTH OF PAVERS, ASPHALT SHALL BE SAWCUT TO A CLEAN EDGE AND ADDITIONAL PAVERS MATCHING EXISTING PAVERS SHALL BE INSTALLED. CONSULT LANDSCAPE ARCHITECT FOR INSTALLATION. IN SOD AREAS ON PRIVATE PROPERTY, TRENCH SHALL BE CUT WITH SOD CUTTER AND RESTORED WITH TOPSOIL AND NEW SOD.3'X7' CONCRETE PAD FOR FUTURE BENCH (TYP.) SEE DETAIL 2/C-6.1 MAIN T R AI L ( E XI S TI N G ) OLANDER DRIVE S D S S NEW TRAIL TO USE ESTABLISHED TRAIL BED EX. LARGE BEECH TREE TO REMAIN EX. LARGE BEECH TREE TO REMAIN FOUNTAIN BASIN TO BE EXPOSED AND CLEANED REMOVE CONCRETE SLAB; CUT AND CAP PIPE CLEAR AND GRUB PRIOR TO TRAIL CONSTRUCTION Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-4 MARCH 11, 2020 AS NOTED LC CC/JS MEMORIAL PARK SITE PLAN 0 20105 30 BID DOCUMENTS 0 402010 60 RESTORATION NOTES 1.ALL DISTURBED AREAS SHALL BE SEEDED WITH NEW ENGLAND CONSERVATION/WILDLIFE MIX AT A RATE OF 25 LBS/ACRE OR 1,750 SQ.FT./LB NOTES 1.THIS PLAN IS BASED ON A COLLECTION OF MULTIPLE PREVIOUS SURVEY PLANS. LOCATIONS OF UTILITIES SHOWN HEREON ARE THE RESULT OF SURFACE EVIDENCE AS LOCATED BY FIELD SURVEY, PLANS OF RECORD, AND OTHER AVAILABLE SOURCES. THIS PLAN DOES NOT NECESSARILY DEPICT THE EXACT LOCATIONS OF ALL UTILITIES WHICH MAY EXIST AT THIS TIME WITHIN THE PREMISES SURVEYED. 1.ALL CONCRETE SIDEWALKS/WALKWAYS SHALL CONFORM TO THE MASSACHUSETTS ARCHITECTURAL ACCESS BOARD'S (AAB) REQUIREMENTS. TYPICAL SIDEWALK/WALKWAY CROSS-SLOPE IS 1.0% MINIMUM, 2.0% MAXIMUM. 2.ASPHALT PATH SHALL CONFORM TO THE UNITED STATES ACCESS BOARD STANDARDS FOR OUTDOOR DEVELOPED AREAS. TYPICAL CROSS SLOPE IS 1.5% AND SHALL NOT EXCEED 2.0%. THE SLOPE AT SWITCHBACK LANDING AREAS SHALL NOT EXCEED 2% IN ANY DIRECTION FROM PC TO PT. LONGITUDINAL SLOPE SHALL NOT EXCEED 8% AT ANY LOCATION. 3.ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO THE CONSTRUCTION STANDARDS AND SPECIFICATIONS OF THE CITY OF NORTHAMPTON AND THE MASSACHUSETTS DEPARTMENT OF TRANSPORTATION. 4.THIS PLAN IS PREPARED AS AN ENGINEERING DESIGN AND IS NOT INTENDED TO BE USED FOR THE DETERMINATION OF PROPERTY LINES. EXISTING CONDITIONS //////////////////////////////Gravel210205215220TRAIL FROM HIGGINS WAYTO BE CONSTRUCTED BY OTHERSEXISTING GRAVEL TRAIL223224225222220219218212213214215216217218R340'R170'221CONNECT TO EXISTING MULTI-USE TRAIL MULTI-USE TRAIL 10' WIDE GRAVEL PATH SEE DETAIL 8/C-6.1 LENGTH = 150 LINEAR FEET STRAW WATTLE AND SILT FENCE AT DOWN-SLOPE LIMIT OF WORK . SEE DETAIL 2/C-6.2 EXISTING TRAIL SURFACE MATERIAL (IF ANY) TO BE REMOVED AND AREA SEEDED. GRADE TO CONTOURS SHOWN, LOAM AND SEED INSTALL EROSION CONTROL BLANKET LIMIT GRADING AROUND TREES TO EXTENT SHOWN. TREES TO BE PROTECTED WITH 2X 4 LUMBER (8' LONG MINIMUM) SECURED WITH WIRE. BURLAP SHALL BE PLACED BETWEEN CLADDING AND TRUNK TO PREVENT DAMAGE. Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-5 MARCH 11, 2020 1" = 10' LC CC/JS MULTI-USE PATH CONNECTION 0 20105 30 BID DOCUMENTS RESTORATION NOTES: RESTORE ALL DISTURBED AREAS WITH NEW ENGLAND CONSERVATION/WILDLIFE MIX APPLICATION RATE: 25LBS/ACRE | 1750 SQ FT/LB SPECIES: VIRGINIA WILD RYE (ELYMUS VIRGINICUS), LITTLE BLUESTEM (SCHIZACHYRIUM SCOPARIUM), BIG BLUESTEM (ANDROPOGON GERARDII), RED FESCUE (FESTUCA RUBRA), SWITCH GRASS (PANICUM VIRGATUM), PARTRIDGE PEA (CHAMAECRISTA FASCICULATA), PANICLED LEAF TICK TREFOIL (DESMODIUM PANICULATUM), INDIAN GRASS (SORGHASTRUM NUTANS), BLUE VERVAIN (VERBENA HASTATA), BUTTERFLY MILKWEED (ASCLEPIAS TUBEROSA), BLACK EYED SUSAN (RUDBECKIA HIRTA), COMMON SNEEZEWEED (HELENIUM AUTUNALE), HEATH ASTER (ASTERPILOSUS/SYMPHYOTRICHUM PILOSUM), EARLY GOLDENROD (SOLIDAGO JUNCEA), UPLAND BENTGRASS (AGROSTIS PERENNANS). Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-6.1 MARCH 11, 2020 AS NOTED LC JS DETAILS UNDISTURBED OR COMPACTED SUBGRADE NOTE: IF UNSUITABLE CONDITIONS ARE ENCOUNTERED, DEPTH OF BASE MATERIAL MAY BE INCREASED IN THE FIELD. EXTEND GRAVEL 12" BEYOND EDGE OF PAVING WHERE ROAD IS NOT CURBED 2-1/2'' 12'' 12'' ASPHALT PAVEMENT1NOT TO SCALE GRAVEL BORROW BASE COURSE MDOT M1.03.1 TYPE B, 95% MIN. DENSITY MDOT HOT MIX ASPHALT TOP COURSE (N.I.C.) MDOT M3.11.03, TABLE A MDOT HOT MIX ASPHALT BINDER COURSE MDOT M3.11.03, TABLE A POLYETHYLENE FILLER NOTE: 1/2'' PREMOLDED 8''2''2''COMPACTED SUBGRADE UNDISTURBED OR 4,500 P.S.I. WIRE MESH WITH 6''x6''x10/10 4'' CONCRETE GRAVEL BORROW BASE COURSE MDOT M1.03 TYPE B, 95% DENSITY POLYURETHANE OR POLYSULFIDE JOINT SEALANT (1/2" DEEP) SCARIFY EDGES OF JOINT WITH WIRE BRUSH AND CLEAN-OFF FINES, PRIOR TO INSTALLING SEALANT. 1.CONCRETE FINISH TO BE MEDIUM TEXTURE BROOM FINISH PERPENDICULAR TO DIRECTION OF WALK WITH 3'' TROWELLED EDGES 2.WALKWAYS: SCORING EVERY 5', EXPANSION JOINTS EVERY 20' UNLESS OTHERWISE INDICATED ON PLAN; PROVIDE EXPANSION JOINTS AT ALL VERTICAL WALLS & ISOLATION JOINTS AT ALL FOOTINGS 3.SCORING LINES TO BE AT LEAST 1/4 THICKNESS OF SIDEWALK 4.JOINT SEALANT SHALL BE SELF LEVELING ON SLOPES UNDER 2% AND NON SAG ON SLOPES GREATER THAN 2%. NOTES: 1.TABLES SHOW THE MINIMUM ACCEPTABLE BEARING DIMENSIONS. 2.PROVIDE BLOCKS FOR TAPPING SLEEVES, DEAD ENDS, GATE VALVES, AND VERTICAL BENDS (SAME SIZE AS REQUIRED FOR TEES). PROVIDE ANCHOR ROADS AT VERTICAL BENDS AND GATE VALVES. 3.CONCRETE SHALL NOT BE PLACED AGAINST PIPE BEYOND FITTING. 4.THRUST BLOCKS SHALL NOT BEAR AGAINST UNSUITABLE SOILS. BENDS PIPE SIZE BEND ANGLE B C PIPE SIZE BEND ANGLE B C 4"11.25°18"12"8"11.25°24"18" 4"22.5°18"12"8"22.5°24"18" 4"45°18"12"8"45°30"18" 4"90°24"18"8"90°36"36" 6"11.25°24"18"12"11.25°24"18" 6"22.5°36"24"12"22.5°36"24" 6"45°24"18"12"45°48"36" 6"90°36"18"12"90°60"48" 12" (MIN.)B 24" 8" (MIN.)C UNDISTURBED OR COMPACTED SUBGRADE A A PLAN SECTION A-A TEES & DEAD ENDS PIPE SIZE E F 4"18"18" 6"24"24" 8"36"24" 10"42"36" 12"48"42" 12" (MIN.)E 24" 8" (MIN.)F UNDISTURBED OR COMPACTED SUBGRADE D D PLAN SECTION D-D6''MODT HOT MIX ASPHALT BINDER COURSE GRANITE CURB, TYPE ''VB'' MATERIAL VARIES, SEE PLAN COMPACTED GRAVEL UNDISTURBED OR COMPACTED SUBGRADE BASE AND BACKFILL,12'' 6''MIN.AS MDOT HOT MIX ASPHALT WEARING COURSE 6'' SPECIFIED 6'' AS SPECIFIED 95% MIN. DENSITY 3000 PSI CEMENT CONCRETE MIN.MIN. CONCRETE SIDEWALK2NOT TO SCALE GRANITE CURB3NOT TO SCALE THRUST BLOCKS11NOT TO SCALE BID DOCUMENTS COMPACTED STONE DUST WEED-PREVENTING PERFORATED POLYFILM, SEE SPECIFICATIONS UNDISTURBED OR4''8''COMPACTED SUBBASE NOTE: SEE PLAN FOR DIMENSIONS EXTEND GRAVEL 12" BEYOND EDGE OF ASPHALT MDOT TYPE B GRAVEL BORROWCOMPACTED TO 95% OF MAXDRY DENSITY 8'' x 8'' POST 3'' x 10'' RAIL 8'-0'' O.C.2'' CHAMFER 6''2'-6''FINISH GRADE 5/8''x7 1/2'' BOLTS COUNTERSUNK VANDAL PROOFED NOTES: 1. ALL WOOD TO BE PRESSURE TREATED, 2. ALL HARDWARE SHALL BE GALVANIZED 3. SET POSTS 3' - 6'' DEEP IN WELL-3'-0"6"6"6" SELECT PINE GRADE 'B' OR BETTER TAMPED GRAVEL BACKFILL CONCRETE BLOCK RETAINING WALL5NOT TO SCALE TIMBER GUARDRAIL6NOT TO SCALE 12'' 1 1/2'' MDOT HOT MIX ASPHALT WEARING COURSE 8'' 1 1/2" MDOT HOT MIX ASPHALT BINDER COURSE MDOT TYPE B GRAVEL BORROW COMPACTED TO 95% OF MAXDRY DENSITY ASPHALT PATH7NOT TO SCALE GRAVEL PATH8NOT TO SCALE THREADED PLUG TO BE ABOVE GRADE 45° PVC BEND PIPE SEE PLAN FOR SIZE FINISH GRADE - SEE PLAN FOR MATERIAL 4" PVC CONDUIT COMPACTED SUBGRADE 4X4X4 PVC WYE THREADED PLUG CLEANOUT FOR END OF GAS CONDUIT10NOT TO SCALE 24" FINISH GRADE (OR CURB) AS SHOWN ON PLAN 4'-0"Ø ±1"4'-0" MIN.2"5" MIN.18" MIN.5" MIN.2' TO 4'BASE SECTION6" MIN.FRAME TO BE SET IN FULL BED OF MORTAR 5" M I N . HINGED CAST IRON HOOD IN PAVED AREAS (AS PER MA DOT STANDARD CATCH BASIN HOOD) OUTLET PIPE; MATERIAL, SIZE & SLOPE AS SHOWN ON PLAN "V" OPENING FILLED WITH NON-SHRINK MORTAR PRECAST CONCRETE RISER SECTION1' TO 4' RISERSECTIONSMORTAR ALL JOINTS PIPE BEDDING AS PER UTILITY TRENCH REQUIREMENTS COMPACTED GRAVEL BORROW COMPACTED 3/4" CRUSHED STONE UNDISTURBED OR COMPACTED SUBGRADE NOTES 1.WEEP HOLES SHALL BE 4" SDR35 PVC PIPE 12" LONG PLACED THROUGH EACH WALL OF CATCH BASIN. OUTSIDE END TO BE COVERED WITH 1/4" MESH, GALVANIZED WIRE SCREEN. PLACE 1/4 CUBIC YARD 3/4" CRUSHED STONE AROUND OUTSIDE END OF PIPE. USE MINIMUM OF 3 WEEP HOLES PER BASIN. 2.CONTRACTOR MAY UTILIZE PRECAST FLAT TOP SECTION WHERE DEPTH OF BASIN PROHIBITS THE USE OF CONICAL SECTION. 3.CONCRETE COMPRESSIVE STRENGTH SHALL BE 4,000 PSI (MIN.). 4.STRUCTURE SHALL BE REINFORCED TO MEET OR EXCEED H20 LOADING. BRICK AS REQUIRED TO ADJUST TO GRADE (12" MAX.) PRECAST CONICAL SECTION WEEP HOLE (MIN. 3) PRECAST CONCRETE BASE SECTION BICYCLE-SAFE CAST IRON CATCH BASIN GRATE 6" MIN.8"8" CATCH BASIN9NOT TO SCALE18"WALL BLOCK UNIT, CAP BLOCK UNIT,18"GEOTEXTILE FABRIC 12" MIN. BEHIND WALLBACKFILL TO EXTEND 3/4" CRUSHED STONE NON-WOVEN INSTALL PER MANUFACTURER'SINSTRUCTIONS INSTRUCTIONSINSTALL PER MANUF. EX. GRADE 18"LEVELLING PAD 3/4" CRUSHED STONE 6"BOTTOM BLOCK UNIT, INSTALL PER MANUFACT.INSTRUCTIONS NOTE:RETAINING WALL TO BE LARGE BLOCK GRAVITY WALL SYSTEM, WITH 18" MIN. HEIGHTBLOCKS, & INCLUDE A GROUTED METAL GUARDRAIL & WOOD GUARDRAIL. MANUFACTUERERS INCLUDE: 1. REDI ROCK, 603-863-1000 2. STONE STRONG SYSTEMS, 860-653-506318"4" PERF. PVC SUBDRAIN FINISH GRADE SEE DETAIL 6/C-6.1 WOOD GUARD RAIL CONTRACTOR SHALL PROVIDE STAMPED ENGINEERED DRAWINGS FROM THE APPROVED MANUFACTURER PRIOR TO CONSTRUCTION. SECURE CAP BLOCK TO FREESTANDING BLOCK WITH POLYURETHANE SEALANT. OPTIONAL SHEAR LUGS CAST INTO CAP BLOCK OR REBAR TIES THAT CAN BE EMBEDDED IN SITE-CONCRETE (WITH GARDEN BLOCK) ARE ALSO AVAILABLE.VARIES18"2" WASHED STONE ALONG BACK OF WALL. 6" DEPTH. WALL MANUFACTURER SHALL MATCH WALL INSTALLED AS PART OF OLANDER EXTENSION PROJECT.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL. FLUSH GRANITE CURB GRADE TO EXISTING GRADE @ 2%ROAD SURFACE FLOW FLUSH GRANITE CURB 18" GRANITE CURB TRANSITION EITHER SIDE. 36" ELEVATION CURB OPENING4NOT TO SCALE (N.I.C.)1-1/2" SECTION Checked By: Drawn By: Revisions Scale: Date:Sheet Number This drawing is not intended nor shall it be used for construction purposes unless the signed professional seal of a registered landscape architect, civil engineer or land surveyor employed by The Berkshire Design Group, Inc. is affixed above. Web: http://www.berkshiredesign.com Email: bdg@berkshiredesign.com (413) 582-7000 4 Allen Place, Northampton, Massachusetts 01060 FAX (413) 582-7005 Landscape Architecture Civil Engineering Planning Berkshire Group Design Do not scale drawing for quantity take-offs or construction. Use written dimensions only. If dimensions are incomplete, contact The Berkshire Design Group Inc. for clarification. Land Surveying Copyright The Berkshire Design Group, Inc. This drawing and all of its contents are the express property of The Berkshire Design Group, Inc., and shall not be copied or used in any way without the written consent of The Berkshire Design Group, Inc. c OLANDER DRIVE EXTENSION VILLAGE HILL NORTHAMPTON, MASSACHUSETTS C-6.2 MARCH 11, 2020 AS NOTED LC JS DETAILS BID DOCUMENTS ADJACENT ROLLS SHALL TIGHTLY ABUT 12" DIA. STRAW WATTLES SECTION SILT FENCE TUCKED UNDER STRAW WATTLE SILT FENCE SILT FENCE ENTRENCHED 3" FLOW EROSION CONTROL BARRIER2NOT TO SCALE STRAW WATTLE3NOT TO SCALE 50' min. 8"min. PRIVATE ROAD GEOTEXTILE SEPARATION FABRIC 2"-3'' WASHED COARSE EXIST. GROUND FOR FULL WIDTH AND LENGTH AGGREGATE STABILIZED CONSTRUCTION ACCESS NOTES: 1. DIMENSIONS:WIDTH: 15' FLARED TO 25' AT ROADWAY LENGTH: 50' MIN. GRADE AND CROSS SLOPE: 2% 2. CLEAR ACCESS OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONAL MATERIAL. 3. GRAVEL PAD SUBGRADE SHALL BE GRADED SO THAT THE ACCESS WILL NOT DRAIN OFF SITE. 4. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD, SEDIMENT, ETC. FROM LEAVING THE SITE. SHOULD MUD/SEDIMENT BE TRACKED OR WASHED INTO THE PUBLIC ROAD IT SHALL BE REMOVED IMMEDIATELY. STABILIZED CONSTRUCTION ENTRANCE1NOT TO SCALE AND BURLAP FROM TOP REMOVE ALL TWINE, ROPE UNDISTURBED OR PLANTING SOIL 4" HIGH EARTH SAUCER SET FLAIR AT OR ABOVE FIN. GRADE 18"8" MULCH RING; 6' MIN. DIAMETER, MARK NORTH SIDE OF THE TREE IN THE NURSERY, ROTATE TREE TO FACE NORTH AT SITE, IF POSSIBLE DO NOT HEAVILY PRUNE TREE AT PLANTING; PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN OR DEAD BRANCHES. (SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN.) 2" DEPTH; DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK BEYOND EDGE OF ROOT BALL 1/2 OF ROOT BALL COMPACTED SUBGRADE FERTILIZER ROOT PACKET, 2 PER TREE, 6"-8" DEEP, PLACED AS ROOT BALL IS BACKFILLED NOTE: DO NOT STAKE OR WRAP TRUNK * EACH TREE SHALL BE PLANTED SUCH THAT THE TRUNK BASE FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. DO NOT COVER THE TOP OF THE ROOT BALL WITH SOIL *FIN. GRADE FOR BALL AND BURLAPPED TREES (B&B), REMOVE THE BURLAP AND BASKET (SEE NOTES) NOTES 1.THE FOLLOWING PROCEDURE SHALL BE USED FOR BALL AND BURLAPPED TREES: 1.1.CUT OFF THE BOTTOM PORTION OF THE BASKET 1.2.ROLLING THE TREE IN THE HOLE AND STAND IT UP STRAIGHT 1.3.CUT THE REMAINS OF THE BASKET 1.4.PULL DOWN THE BURLAP AND CUT OFF THE EXCESS TYPICAL TREE PLANTING4NOT TO SCALE TREE PROTECTION5NOT TO SCALE 2"x2" WOODEN STAKE STRAW WATTLE 12-18" TYP. WORK AREA AREA TO BE PROTECTED3"STRAW WATTLE PLAN VIEW STRAW WATTLE SECTION WATER FLOW WORK AREA AREA TO BE PROTECTED STAKE EVERY 10± STRAW WATTLE 1'NOTE: 1.ALL MATERIAL TO MEET STRAW WATTLE SPECIFICATIONS 2.STRAW WATTLE COMPOST/SOIL/ROCK/SEED FILL TO MEET APPLICATION REQUIREMENTS 3.STRAW WATTLE DEPICTED IS FOR MINIMUM SLOPES. GREATER SLOPES MAY REQUIRE LARGER SOCKS PER THE LANDSCAPE ARCHITECT 4.COMPOST MATERIAL TO BE DISPERSED ON SITE, AS DETERMINED BY THE LANDSCAPE ARCHITECT BACK FILL & WATER TREE WITH SOIL ONCE TREE IS STABILIZED. DO NOT TAMP WITH FOOT OR OTHER MECHANICAL DEVICES. HALFWAY THROUGH THE BACK-FILLING PROCESS, WATER THE TREE TO HELP REMOVE AIR POCKETS TO AVOID FUTURE SETTLING. ONCE BACK FILL IS COMPLETE THOROUGHLY WATER THE TREE.