35-285 (11) 28 SYLVAN LN BP-2020-0761
GIS#: COMMONWEALTH OF MASSACHUSETTS
Ma:Block: 35-285 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: SOLAR ELECTRIC SYSTEM BUILDING P E RM I T
Permit# BP-2020-0761
Project# JS-2020-001314
Est.Cost: $28360.00
Fee:$75.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: REVOLUSUN 062112
Lot Size(sq. ft.): 33279.84 Owner: LEVAY BRADLEY J
tonin : Applicant. REVOLUSUN
AT. 28 SYLVAN LN
Applicant Address: Phone: Insnranc e:
1 NORTH AVE SUITE A (781) 270-6555 WC
BURLINGTONMA01803 ISSUED ON:12/30/2019 0:00:00
TO PERFORM THE FOLLOWING WORK.-ROOFTOP SOLAR ARRAY-26 PANELS, 8.84 KW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeTvpe: Date Paid: Amount:
Building 12/30/2019 0:00:00 $75.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
r Department use only
City of Northampton Status of Permit:
Building Department Curb Cut/Driveway Permit
212 Main Street Sewer/Septic Availability
DEC Room 100 Water/WellAvailability
2 6 2019 Orth mpton, MA 01060 Two Sets of Structural Plans
' phone 4 3-5 7-1240 Fax 413-587-1272 Plot/Site Plans
DF aF Sull"' ' Other Specify
IP/c
APPLI " NSTR CT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION
1.1 Property Address: This section to be com leted by office
28 Sylvan Lane Map Lot�z �� Unit
Northampton MA 01062
Zone Overlay District
Elm St.District CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
2.1 Owner of Record:
28 Sylvan Lane
Bradley LEVAY III Northampton MA 01062
NpMql-Mfi4}--d by Current Mailing Address:
(413) 320-3303
V Telephone
Signa r9A08F73941`5..
2.2 Authorized Agent:
Northeast Solar Services dba Revolusun 1 North Avenue,Suite A,Burlington,MA 01803
Name in Current Mailing Address:
(781) 270-6555 louis.yarid@revolusun.com
S natur Telephone Email
SECTION 3- IMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building $9642.47 (a) Building Permit Fee
2. Electrical (b) Estimated Total Cost of
$ 18717.75 Construction from 6
3. Plumbing Building Permit Fee
4. Mechanical(HVAC)
5. Fire Protection
6. Total=0 +2+3+4+5) $28360.22 Check Number
ff This Section For Official Use Only
Building Permit Number: 1' " f-7 Date
Issued:
Signature: v0
Building Commissioner/Inspector of Buildings Date
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House Addition Replacement Windows Alteration(s) Roofing
Or Doors
Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other[X]
Solar Photovoltaic
Brief Description of Proposed
Work: Install Solar array and connect with existing utility. Type: Rooftop Qty. Panels: 26 kW DC: 8.84
Alteration of existing bedroom Yes X No Adding new bedroom Yes X No
Attached Narrative Renovating unfinished basement Yes X No
Plans Attached Roll -Sheet
6a. If New house and or addition to existing housing, complete the following:
a. Use of building:One Family Two Family Other
b. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new construction. Dimensions
e. Number of stories?
f. Method of heating? Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j. Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No.
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I, Bradley LEVAY III as Owner of the subject
property
hereby authorize Northeast Solar Services dba Revolusun
toehalf, in all matters relative to work authorized by this building permit application.
rzoz ( V 111 12/11/2019
Si t�Q§GId@tFe... Date
I, Louis Yarid of Northeast Solar Services dba Revolusun as Owner/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Louis Yarid
Print
71— 12/11/2019
ignatu f er/A nt Date
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder: Joseph Vaccaro CS-062112 (U)
License Number
16 Sunnyside Avenue,Winthrop,MA 02152 1/23/2020
Address Expiration Date
781 281-6012
Si at Telephone
9.Reaistered Home Improvement Contractor: Not Applicable ❑
Northeast Solar Services dba Revolusun 178137
Company Name Registration Number
1 North Avenue,Suite,A, Burlington,MA 01803 3/16/2020
Addre Expiration Date
Q —J
Telephone (781) 270-6555
SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes....... ® No...... ❑
11. - Home Owner Exemption
The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm
structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner.
Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be
responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature
The Commonwealth of Massachusetts
Department of IndustrialAccidents
I Congress Street,Suite 100
Boston,MA 02114-2017
www mass gov/dia
Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers.
TO BE FILED WITH THE PERMITTING AUTHORITY.
Applicant Information Please Print Legibly
Name(Business/Organization/IndividuW): Northeast Solar Services dba Revolusun
Address: 1 North Avenue,Suite A
City/State/Zip: Burlington,MA 01803 Phone#: (781)270-6555
Are you an employer?Check the appropriate box: Type of project(required):
1.nXX I am a employer with 25 employees(full and/or part-time).' 7. ❑ New construction
2.❑I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling
any capacity.[No workers'comp.insurance required.]
9. El Demolition
3.❑I am a homeowner doing all work myself.[No workers'comp.insurance required.]t
10❑Building addition
4.E]I am a homeowner and will be hiring contractors to conduct all work on my property. I will
ensure that all contractors either have workers'compensation insurance or are sole 11.[]Electrical repairs or additions
proprietors with no employees. 12.E]Plumbing repairs or additions
5.E]I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.E]Roof repairs
These sub-contractors have employees and have workers'comp.insurance.:
6.❑we are a corporation and its officers have exercised their right of exemption per MGL c. 14. X❑Other Solar Photovoltaic
152,§1(4),and we have no employees.[No workers'comp.insurance required.]
'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
:Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and joh site
information.
Insurance Company Name: American Zurich Insurance Company
Policy#or Self-ins.Lic.#: UB-7H836175-18 Expiration Date: 12/31/2019
Job Site Address: 28 Sylvan Lane City/State/Zip: Northampton MA 01062
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00
and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a
day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance
coverage verification.
I do hereby certify under the pains3apoenalties ofperjury that the information provided above is true and correct
Signature: s-11 Date: 12/11/2019
Phone#: ( 1)270-6555
Official use only. Do not write in this area,to be completed hv ciry or town official.
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector
6.Other
Contact Person: Phone#:
Client#: 103503 NORTHSOL
DATE(MM/DD/YYYY)
ACORD.. CERTIFICATE OF LIABILITY INSURANCE 11/08/2019
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT:If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on
this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s).
PRODUCER NAMEACT Lauren Luke
Starkweather&Shepley(WW) PHONE 781 320-9660
A/C No Etd, (A�,N,): 401-431-9635
Insurance Corp.of MA ADDRESS: Iluke@starshep.com
PO Box 549 INSURER(S)AFFORDING COVERAGE NAIC#
Providence,RI 02901-0549 INSURER A:Employers Mutual Ins 21415
INSURED INSURER B:
Northeast Solar Services Inc.
INSURER C:
1 North Ave Ste A
Burlington,MA 01803 INSURER D:
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
IN RR TYPE OF INSURANCE INSR WVD POLICY NUMBER POLICY EFF
POLICY EXP
LIMITS
A X COMMERCIAL GENERAL LIABILITY 5D5865319 2/31/2018 12/31/2019
pEAACCH�GOECTCURppRENCE $1000000
CLAIMS-MADE 51OCCUR PREMISES EaE=rrence $500,000
MED EXP(Any one person) $10,000
PERSONAL&ADV INJURY $1,000,000
GEML AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2 OOO,OOO
PRO.
POLICY F_X1 JET LOC PRODUCTS-COMP/OP AGG $2,000,000
OTHER: $
A AUTOMOBILE LIABILITY 5Z5865319 2/31/2018 12/31/201 E.MBa INeDtSINGLELIMIT 1,000,000
ANY AUTO BODILY INJURY(Per person) $
OWNEDIx
SCHEDULED BODILY INJURY(Per accident) $
AUTOS ONLY AUTOS
HIRED NON-OWNED PROPERTY DAMAGE $
X AUTOS ONLY AUTOS ONLY Per accident
$
A X UMBRELLA LIAB X OCCUR 5J5865319 2/31/2018 12131/2019 EACH OCCURRENCE s5,000,000
EXCESS LIAB CLAIMS-MADE AGGREGATE $5,000,000
DED I X I RETENTION$10000 $
WORKERS COMPENSATION PER OTH-
AND EMPLOYERS'LIABILITY Y/N
ANY PROPRIEfOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $
OFFICERIMEMBEREXCLUDED? N/A
(Mandatory in NH) E.L.DISEASE-FA EMPLOYEE $
It yes,describe under
DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $
DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached if more space is required)
dba Revolusun
Re:28 Sylvan Lane, Northampton, MA 01062.
CERTIFICATE HOLDER CANCELLATION
City of Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
y p THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
212 Main Street ACCORDANCE WITH THE POLICY PROVISIONS.
Northampton, MA 01060
AUTHORIZED REPRESENTATIVE
@ 1988-2015 ACORD CORPORATION.All rights reserved.
ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD
#S1395361/M1227352 PAT3
�� • CERTIFICATE OF LIABILITY INSURANCE DA1111112019
TE IMM/DD/YYYY►
TNAS.CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE
R PRODUCER.AND THE CERTIFICATE HOLDER.
IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the
terms and conditions of the policy,certain policies may require and endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER CONTACT
NAME:
STARKWEATHER&SHEPLEY PHONE FAX
60 CATAMORE BLVD (AIC,No,Ext): (A/C,No):
E-MAIL
EAST PROVIDENCE,RI 02914-1206 ADDRESS:
22HHX INSURER(S)AFFORDING COVERAGE NAIC#
INSURED INSURER A: AMERICAN ZURICH INSURANCE COMPANY
NORTHEAST SOLAR SERVICES INC INSURER B:
INSURER C:
INSURER D:
1 NORTH AVENUE SUITE A&B INSURER E:
BURLINGTON,MA 01803 INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING
ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE
AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY
PAID CLAIMS.
INSR %DDL,UBR POLICY EFF DATE POLICY EXP DATE
LTR TYPE OF INSURANCE INSR WVD POLICY NUMBER (MMt)DIYYYY) (MMIDD%YYYY) LIMITS
GENERAL LIABILITY EACH OCCURRENCE $
COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED $
CLAIMS MADE 0 OCCUR. PREMISES(Ea occurrence)
ED EXP(Any one person) $
ERSONAL&ADV INJURY $
GEN'L AGGREGATE LIMIT APPLIES PER: ENERAL AGGREGATE $
POLICY D PROJECT [::]LOC RODUCTS-COMP/OP AGG $
AUTOMOBILE LIABILITY COMBINED SINGLE $
ANY AUTO LIMIT(Ea accident)
ALL OWNED AUTOS BODILY INJURY $
SCHEDULE AUTOS (Per person)
HIRED AUTOS BODILY INJURY $
(Per accident)
NON-OWNED AUTOS PROPERTY DAMAGE $
(Per accident)
UMBRELLA LIAB OCCUR EACH OCCURRENCE $
EXCESS LIAB CLAIMS-MADE AGGREGATE $
DEDUCTIBLE $
RETENTION $ $
A WORKER'S COMPENSATION AND X WC STATUTORY OTHER
EMPLOYER'S LIABILITY YIN UB-7H836175-18 12/31/2018 12/31/2019 LIMITS
ANY PROPERITOR/PARTNER/EXECUTIVE N/A E.L.EACH ACCIDENT $ 11000,000
OFFICER/MEMBER EXCLUDED? El
(Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000
If yes,describeunder
DESCRIPTIIPTIONN OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000
DESCRIPTION OF OPERATIONS/LOCATIONSNEHICLESIRESTRICTIONS/SPECIAL ITEMS
THIS REPLACES ANY PRIOR CERTIFICATE ISSUED TO THE CERTIFICATE HOLDER AFFECTING WORKERS COMP COVERAGE.
CERTIFICATE HOLDER CANCELLATION
CITY OF NORTHAMPTON SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED
212 MAIN ST., BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED
IN ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRl;= '$� �.�
NORTHAMPTON,MA 01060
ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD 1988-2010 ACORD CORPORATION. All rights reserved.
DEBRIS AFFIDAVIT
As a result of the provisions of MGL C. 40, § 54, 1 acknowledge that as a
condition of this Building Permit, all debris resulting from the construction
activity governed by this Building Permit shall be disposed of in a properly
licensed solid waste disposal facility, as defined by MGL C. 111, § 150A.
I certify that I will notify the Building Commissioner of any change in the
location of the solid waste disposal facility to be used within 72 hours.
12/11/2019 l�
Date Si ature of Permit Applicant
Print or type the following information:
Joseph Vaccaro
Name of Permit Applicant
Northeast Solar Services (dba Revolusun)
Firm Name (if applicable)
1 North Avenue, Suite A, Burlington, MA 01803
Address
The debris will be disposed of:
Casella Waste Systems, Inc.
Facility
24 Bunker Hill Industrial Park, Boston, MA 02129
Address
Northeast Solar Services (dba Revolusun) will be removing debris from the work
site daily, and utilizing the disposal service at our headquarters.
OYXe
Office of Consumer Affairs and Business Regulation
One Ashburton Place- Suite 1301
Boston, Massachusetts 02108
Home Improvement Contractor Registration
Type: Supplement Card
Registration: 178137
NORTHEAST SOLAR SERVICES INC. _ Expiration: 03/16/2020
D/B/A REVOLUSUN
1 NORTH AVE.SUITE A
BURLINGTON,MA 01803
,a.,. ,fie •
Update Address and Return Card.
SCA 1 O 20M�-0611(77
-'//!v {['ONt ilrnrtnM?�/�i n/�'/�n.ila�rul✓/•
office of Consumer Affairs 8 Business Regulation
HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only
TYPE:SUpOlernent Card before the expiration date. If found return to:
Registration gxlLiration Office of Consumer Affairs and Business Regulation
178137 03/16/2020 One Ashburton Place-Suite 1301
NORTHEAST SOLAR SEHVICES INC. Boston,MA 02108
D/B/A REVOLUSUN
LOUIS YARID
1 NORTH AVE.SUITE A it lid without signature
BURLINGTON,MA 01803 Undersecretary
® Commonwealth
Division of Prot--
Board of Budding RegL,
Construction 5
CS-062112 Expires:01 212020
JOSEPH W VACCARO -
16 SUNNYSIDE AVE
WNTHROP MA 02152
Commissioner
�DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
REVOLU�SUN
a
THIS HOME IMPROVEMENT SOLAR ENERGY CONTRACT(this"Contract")IS BETWEEN:Bradley Levay III("Client")located at 28 Sylvan Ln
Northampton,MA 01062("Client's Property")
-AND-
Northeast Solar Services,Inc.®("Contractor")of 1 North Ave Suite A Burlington,MA 01803,with Home Improvement Contractor Reg.No.178137,which
expires on March 16,2020,and Federal Employer ID 46 0569853.Contractor's Project Developer for this contract is Richie Bonney.
The parties to this Agreement agree as follows:
I.SCOPE OF WORK
A.Installation of PV System.The above Client(s)has engaged Contractor to perform the following residential contracting work(the"Work")in connection
with the installation of the following photovoltaic solar energy system(the"PV System"):
26 Panasonic-Panasonic N340 watt modules(or equivalent) with 1 Solar Edge-SolarEdge SE 7600H inverters(or equivalent)and all mounting,
disconnects,and all other PV System components necessary for a National Electric Code compliant PV System,totaling 8.84kW,located at Client's
Property.
B.Other Inclusions The Work shall further include:
•Installation of the PV System in accordance with all State of Massachusetts interconnection standards.
•All reasonable engineering and permitting costs.
•The following building permits are required and will be secured by Contractor as Client's agent:Building and Electrical Permit.
•Client authorizes the contractor to procure any and all interconnection documents required by the utility.
•Following the installation,Client will receive a PV System orientation and a PV System Client's manual.
•Notice: It shall be the obligation of the Contractor to obtain all permits related to the Work. Clients who secure their own permits will be excluded
from the guarantee fund provisions of Chapter 142A of the Massachusetts General Laws.
It.COMPENSATION AND SCHEDULE
A.Contract Price For Contractor's performance of the Work under this Contract,Client will pay Contractor a total of:
$28,360.22(TWENTY EIGHT THOUSAND THREE HUNDRED SIXTY AND 22/100)DOLLARS USD(the"Contract Price").
B.Payment Schedule The Contract Price will be payable in accordance with the following payment schedule:
Date Paid:
$14.180.11 Initial Payment-50% (Due upon Contract signing,which is an amount less than the cost of the materials and equipment
which must be specially ordered in advance of commencement of PV System installation)
$12.762.09 Progress Payment-45% (Due upon Substantial Completion)
$1.418.02 Final Payment-5% (Due upon Final Completion)
C.Schedule The"Start Date"of this Contract is the date Contractor receives the full amount of Client's initial payment of 50%of the Contract Price.
Subject to adjustment for any Force Majeure reason stated in Section IV.J.,the Work is estimated to begin within 12-16 weeks from the Start Date of this
Contract.The parties agree that this date shall be automatically extended to the date of delivery of all materials and equipment which must be specially
ordered.
Substantial Completion is estimated to occur within 16-20 weeks from the Start Date of this Contract,but the parties agree that this date shall be
automatically shortened or extended to the date on which all racking and electrical work are complete and the PV System is
capable of generating power and ready and available for use subject to final government and utility approval.
Final Com l� is defined as the date on which all punch list items are complete,all permits are closed,all other government and utility
approvals are obtained and the Work is complete to the satisfaction of Contractor and Client.
Client acknowledges and agrees that the Work involves permits,inspections and approvals from various government agencies and utilities,and
therefore the timing of the Work may vary and is not within Contractor's control. Client further agrees that Contractor shall not be liable for any losses,
costs or damages related to any delays for reasons beyond Contractor's control,including all causes noted in the Force Majeure section of this
Contract below.
***3rd party Financing:Should the Client obtain financing from a 3rd party which is approved by the Contractor,the payment terms of the lender will
apply.A$500.00 deposit paid by the client is required for all 3rd party financing options.
1 Northeast Solar
1 North Ave Suite A
Burlington,MA 01803
OpRevoluSunxom 781.240.6555
158766 V425 10/31/1019
t
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
REVOLU(SUN
III.IMPORTANT NOTICES
A.Contractor's Registration: All home improvement contractors and subcontractors engaged in home improvement contracting,unless specifically
exempt from registration by provisions of Chapter 142A of the Massachusetts General Laws,must be registered with the Commonwealth of
Massachusetts. Inquiries about registration and status should be made to the Director of the following state agency:
Office of Consumer Affairs and Business Regulation
Home Improvement Contractor Registration
Ten Park Plaza,Room 5170
Boston,MA 02116
(617)973-8700
B.Client's Cancellation Rights: Client may cancel this Contract,without penalty or obligation,within three business days following the date on which
Client signs this Contract. A Notice of Cancellation is attached hereto for Client's convenience.
C.Warranties:For a period of ten(10)years from Substantial Completion,Contractor warrants that the PV System has been designed and installed in a
good,workmanlike and substantial manner in accordance with all applicable building codes.
In the event Contractor is required to penetrate the roof of the Client's property in the course of installation,and causes damage to the roof within a three
(3)inch radius of a penetration,Contractor will repair such roof damage for a period of twenty(20)years from Substantial Completion or the remaining
term of the roofs existing installation warranty,whichever is shorter,to prevent any water,rain or other moisture leak,seepage or entry directly caused by
such penetration.These warranties are for normal use and conditions only.All warranty coverage to equipment and workmanship installed by Contractor
will be VOID if any alterations or repairs are performed by any person or persons not expressly authorized,in writing,by Contractor.THIS WARRANTY
DOES NOT COVER:(a)Damage caused by external forces such as,but not limited to,vandalism,theft,terrorism,fire or act of God;(b)Damage caused
by weather effects exceeding manufacturer tolerances;(c)Normal wear and tear or aging of a PV System;(d)Any implied warranties:(e)Electric bills,
water damages or any other consequential damages;or(f)Damage to the PV System or its efficiency due to adjustment,moving,or tampering with the
PV System or any of its components by individuals not approved by Contractor.
D.Change Orders: Any alteration or deviation from above specifications involving extra costs must be subject to a written change order signed by both
parties,which shall be incorporated into this Contract,and Client shall be liable for any additional costs resulting from each change order. By initialing the
space below,Client hereby specifically agrees to execute a change order,and pay the additional costs,if it becomes necessary for Contractor to repair or
replace un-approved or non-code compliant electrical work in order to complete the PV System installation and satisfy code requirements.
In the event the Contractor is required to dig a trench or footings,the Client agrees to pay the additional labor and materials costs if large and/or excessive
rocks need to be removed and cause delays in the time required to complete the trench.If the presence of rocks prevents the driving of ground mount
posts,the Client agrees to pay the additional costs incurred by the Contractor for concrete footings.All rocks uncovered during excavation will remain on
the Clients'Propeq.The cost of such work is agreed to be on a time and material basis.
Client's Initials: l"
Client's Initials:
ARBITRATION: CONTRACTOR AND CLIENT HEREBY MUTUALLY AGREE IN ADVANCE THAT IN THE EVENT CONTRACTOR HAS A DISPUTE
CONCERNING THIS CONTRACT,THE CONTRACTOR MAY SUBMIT SUCH DISPUTE TO A PRIVATE ARBITRATION SERVICE WHICH HAS BEEN
APPROVED BY THE DIRECTOR OF THE EXECUTIVE OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATIONS AND CLIENT SHALL BE
REQ IT TO SUCH ARBITRATION AS PROVIDED IN M.G.L.c.142A.
10/31/2019
ClieDate:
Clie Date:
Contractor: Date: 107 3112019
seSWAzecFa 5_
NOTICE: The signatures of the parties above apply only to the agreement of the parties to alternate dispute resolution initiated by Contractor. Client may
initiate alternate dispute resolution even where this section is not separately signed by the parties.
E.Incentive Guarantee: By Client's initials below,Client acknowledges and agrees that Contractor has not and does not guarantee Client's qualification
for,receipt of or amount of any tax credit,rebate or other incentive amount in connection with the PV System,and any estimates of incentives(whether in
a PV System proposal or otherwise)are not guaranteed to be accurate or available. Client is responsible for determining Client's and/or the PV System's
eligibility for any incentives and should consult with tax,legal and other advisors regarding availability and possible tax consequences of claiming the
same. Ire,
Client's Initials:l��
Client's Initials:
2 Northeast Solar
1 North Ave Suite A
Burlington,MA 01803
OoRevoluSunxom 781.240.6555
158786 V425 10/37/20
19
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
REVOLU('
IV OTHER TERMS AND CONDITIONS
A.Access: To enable Contractor to perform its Work hereunder,Client shall grant during daylight hours adequate space on Client's property,as mutually
designated by Contractor and Client,for the complete and proper installation,operation,maintenance and repair of the PV System as well as rights of
ingress and egress to,through and from such property and the space designated for the PV System.
B.Scarcity of Materials:Rights of Termination: The PV System components to be obtained under this Contract are scarce commodities.If,due to code
requirements,equipment substitution,final engineering,space availability,etc.,the size of a PV System decreases,Contractor shall re-calculate the
Contract Price using its standard pricing method and the Contract Price shall be automatically reduced.Client shall be credited by the reduced amount. If
due to substitution the DC STC size of the PV System increases slightly,then Client shall not have to pay Contractor similarly. Contractor shall make
every reasonable effort to ensure that PV System size does not decrease from the specifications. If the DC STC size of the PV System decreases more
than 15%from the Contract's specification amount for any of the reasons stated in this paragraph,Client shall have the right to terminate this Contract
within ten(10)days of Contractor's written notification to Client of such decrease,and Contractor shall then refund in full all funds paid to date under this
Contract,but shall have no other liability to Client.
Contractor reserves the right to unilaterally terminate this Contract within 45 days of its approval without any liability to Client if any of the PV System
components required for the completion of Contractor's Work in a timely manner are not available. In the event of such termination,Contractor shall
refund all monies paid by Client to Contractor as of the date of termination.
C.Limitation of Liability:In no event shall Contractor be liable in an amount exceeding the compensation paid by Client to Contractor under this Contract.
Contractor shall not be liable for any incidental,consequential or special damages or for economic loss or expense of for loss or profits or income of
Client,or Client's consultants or agents or employees,or any of them,including but not limited to any electricity costs incurred should installation of the PV
System be delayed beyond the commencement or completion schedule set forth above.
D.Zoning:Client shall pay for all variances,special permits,or other costs related to zoning,including without limitation any fees or costs related to
attorneys or engineers.
E.Client's Property:Client agrees to remove or to protect any of Client's personal property,inside or out,which may interfere with or obstruct the Work,
including but not limited to landscaping,and Contractor shall not be held responsible for damage to such property. Client understands and acknowledges
that proper operation of the PV System purchased hereunder is dependent on Client's existing roof and equipment and Contractor shall have no obligation
or liability for the condition thereof,or any other part of Client's improvements or equipment not purchased hereunder. Client expressly represents that the
roof of the property upon which the PV System will be installed is in good condition,with no known water infiltration problems or other structural defects.
F.Insurance:Client must carry all fire,casualty,hurricane,earthquake,theft,and other insurance related to Client's real and personal property.
G.Cancellation of Contract: If Client cancels or breaches this Contract after the opportunity to execute three(3)day rescission has passed but before
commencement of construction,Client shall pay Contractor the amount of expenses incurred to that date plus 20%of the Contract Price. If Client fails to
pay said amounts within thirty(30)days of Contractor's demand for payment and Contractor files suit,Contractor shall be entitled to recover all of its
damages including its loss of net profits and attomeys'fees and costs if Contractor is the prevailing party.
H.Costs of Collection: If Client fails to pay any amounts owed to Contractor when due,Client shall be liable for all costs of collection,including
reasonable attomeys'fees,plus 18%interest per annum on the unpaid balance. Contractor also shall have option of removing all or part of the PV
System from Client's premises in addition to receiving payment equal to the value of the unpaid balance to cover all or a portion of Contractor's
consequential damages.
I.Liens:Contractor,any subcontractor(s)and any other persons or entities supplying labor and materials to Client under this Contract,have the right
under applicable law to impose a lien on Client's real property for the value of the labor or materials provided. Upon Client's payment of all amounts due
under this Contract,Contractor will provide,upon Client's request,a release and waiver of any liens.
J.Force Maieure:Contractor shall not be liable for any delay in material and/or equipment delivery or for failure to deliver or failure to perform the Work
which results from any cause beyond the Contractor's control. Such causes include but shall not be limited to:an act of God or of the public enemy;an
act(or failure to act)of any government or utility;a fire,flood or epidemic;quarantine,restriction,strike,freight embargo,terrorism,theft or unusually
severe weather;Contractor's inability to obtain necessary materials,labor or transportation;custom permitting caused by Client's site conditions;
homeowner association review or approval;building or other code requirements relating to Client's existing electrical system or building characteristics;
and any other impediments to the installation of the PV System arising from Client's acts or omissions and/or the condition of Client's property.
3 Northeast Solar
1 North Ave Suite A
Burlington,MA 01803
OpRevoluSun.ftcom 781.240.6555
158766 w25 100112o19
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
REVOLU(SUN
K.Legal Compliance and Severability:Contractor and Client acknowledge that the form,substance,content and notices contained in this Contract are
intended to comply with Chapter 142A of the Massachusetts General Laws,and regulations promulgated thereunder. In the event of any instance of non-
compliance,only such portion shall be invalid and the remainder of this Contract shall be in full force and effect. In addition,any such portion not in
compliance shall be read and interpreted so as to have its intended meaning to the maximum extent allowed under such law and applicable regulations.
L.Entire Contract:No Waiver Unless In Writing:This Contract constitutes the entire contract between the parties;there is no representation,warranty,
collateral contract or condition affecting this Contract except as expressed in it. No provisions of this Contract shall be changed or modified,nor shall this
Contract be discharged or waived,in whole or part,except in writing signed by both parties.This Contract shall not be effective until fully executed by
Client and an Authorized Representative of Contractor.
M.Client's Representation of Authority_:If this Contract is signed by less than all of the persons or entities who own the subject property,then Client who
signs this Contract(or any of the provisions hereof)represents to Contractor that he,she or it has full legal authority to bind the other persons and/or
entities.
N.Governing Law:The laws of the Commonwealth of Massachusetts shall govern any proceeding or dispute related to this Contract.
O.Production Gap Guarantee:This production guarantee covers 90%of estimated production(9,502.15 kWhs)in year one(1)and decreases at.5%of
year one(1)production each year for a total term of twenty-five years(25).This guarantee is determined on an annual basis and payments are made
when the aggregate system production falls below total cumulative production estimated.Payments will be made at the end of each anniversary of the
system's in service date of interconnection and based on the retail rate at the time of interconnection.Payment will be made within 30 days of the Client's
request of payment.Production Gap Guarantee is void if site conditions and solar access change after the date of interconnection.
Client's Initials:
Client's Initials:
oocasgosa by by:
Client: Ett
�V M Contractor: f bwal
Bradley Levay III Name: Matthew R Powers
Date: 10/31/2019 Title: CEO
Date: 10/31/2019
C•-„
The Contract is contingent upon the Contractor providing the Client with the Panasonic Enhanced Warranty. Should
bx the a Contractor not be able to produce the warranty documentation the Client may cancel at no penalty.
onftftft4 Northeast Solar
1 North Ave Suite A
Burlington,MA 01803
OoRevoluSunxom 781.240.6555
158766 V425 10/318019
DocuSign Envelope ID:E6E5D335-5674-4F3C-839F-580D3DB8146D
REVOLU(SUN
NOTICE OF CANCELLATION
If you decide that you do not want the goods or services described above,you may cancel this Contract by mailing or delivering a signed and dated copy
of the cancellation notice,or any other similar written notice,to Contractor at the address set forth above no later than midnight of the third business day
following the date on which you signed this Contract.
If you cancel by the date and time indicated,any payment made by you under this Contract will be returned within ten(10)business days following
receipt of your cancellation by Contractor,and any security interest arising out of the transaction will be released.
If you cancel,you must make available to Contractor,at your residence,in substantially as good condition as when you received,any goods delivered to
you under this Contract;or you may,if you wish,comply with Contractor's written instructions regarding the return shipment of the goods at Contractor's
risk and expense. If you fail to make the goods available to Contractor,or if you agree to return the goods to Contractor and fail to do so,then you remain
liable for performance of all obligations under this Contract.
If we do not pick up,or attempt to pick up,the goods within 20 days of the date of your notice of cancellation,you may retain or dispose of them without
further obligation.
I HEREBY CANCEL THIS TRANSACTION:
DO NOT SIGN THIS CONTRACT IF THERE ARE ANY BLANK SPACES.
Client's Signature(sign here only if you wish to Date
cancel this transaction)
Client's Signature sign here only it you wish o Date
cancel this transaction)
CLIENT ACKNOWLEDGES RECEIPT OF
ORIGINAL OF THIS CANCELLATION FORM:
OmuSigmd by:
�I' 10/31/2019
Aqua�SUf�BANE 7394US Date
Signature Date
5 Northeast Solar
1 North Ave Suite A
Burlington,MA 01803
OpRevoluSun.Mom 781.240.6555
158766 V425 10f31/1019
PROJECT DESCRIPTION: ROOF DESCRIPTIONSHEETINDEX
26x340W ROOF MOUNTED SOLAR ROOF � PROJECT MANAGER
V PV-1 SITE PLAN&VICINITY MAP
ROOF AZIMUTH PV-2 ROOF PLAN&MODULES UW CLIFFORD
PHOTOVOLTAIC MODULES TILT
PV-3 MOUNTING DETAIL&P.O.0 DETAIL
SYSTEM SIZE: 8.84 kW DC STC
aM 10' 70' PV-4 ELECTRIC LINE DIAGRAM& ARRAY LOCATION
EQUIPMENT SUMMARY WIRING CALCULATIONS
26 PANASONIC:VBHN340SA17 MODULES 02 40' 1W PV-5 PLACARDS M REVISIONS
01 SOLAREDGE SE760OH-US(240)INVERTER 03 40, M. PV-6 LAYOUT MAP XSCR—M MSE IISV
PV-7 MODULE DATA SHEET j
M 40. M. PV-8 INVERTER DATA SHEET
` PV-9 OPTIMIZER DATA SHEET
I PV-10 RAIL DATA SHEET
PV-11 ATTACHMENT DATA SHEET REVOLU
f
I \ CONTRACTOR INFORMATION
� I
I ` EVOLUSUN MASSACHUSETTS!
\ mtmeeeb�"u"f/.me.mti
t' �p"a�crim�.aremmc�
� ���atnuaraR,
O � _ w�wM^nE usurr.mrM.0
I (E)POOL n
� DATE:111082019
PROJECT NAME
BRADLEY LEVAY III
ROOF#3 i HOUSE PHOTO 26 SYLVAN LN
(07)PANASONIC: / NORTHAMPTON,MA 01052
VBHN340SA17 PHONE:
ROOF#4 / 6CALE:NTS --
'/ EMAIL:
(05)PANASONIC: 85'-7" — - JOBA MA02-20-0025
VBHN340SA17 2-STORY APN NO:—
' _ HOUSE
ROOF#1PROJECT MAIL
LU (06)PANASONIC: PROJECT SITE -- S.8{KW STC
Z — VBHN340SA17
-J 33'-7" T.eXwAc
} (E)MAIN SERVICE/ OQ� ENGINEERING APPROVAL
PANEL
W
Q
aOROOF#2 / Q�
I (08)PANASONIC:
s VBHN340SA17 �^
W EXISTING
40
U) I DRIVEWAY ����ZH OF 414Se026 Sylvan Lane
N O? JAMES A.''NNyG 11/20/2019
O? ADAMS
STRUCTURAL ?�
N No.49748
Eruc ural Review
/ \v,
�sroNA020
LE� Structural Rwiaw BHEETNAM
and Approval Only
�srE PLAN&
For penetration spacing and additional VICINITY MAP
X36.95' n88.60'FRONT PROPERTY LINE attachment information see sheet 5-1
SHEET SIZE
SYLVAN LN GOVERNING CODES ANSI B
SITE OCCUPANCY ECATEGORY:SI 2017 NATIONAL 0 CMR,8th EDITION VICINITY MAP ELECTICAL CODE 11 11 X'17°
1 SITE PLAN WITH ROOF PLAN DESIGN WIND SPEED:117MPH UNDERWRITERS LABORATORIES(UL) SCALE:NTS SHEET NUMBER
EXPOSURE CATEGORY:C STANDARDS
PV-1 SCALE:M2"=1'-0' GROUND SNOW LOAD:40 PSF OSHA 29 CFR 1910.269 PV-1
LOAD CALCULATION PROJECT MANAGER
MODULE TYPE,DIMENSIONS&WEIGHT N OF 14OJIAN CLIFFORD
MODULE TYPE=PANASONIC:VBHN340SA17 ? h 11/20/2019
MODULE WEIGHT=40.81 LBS ?� JAMES A. G TOTAL 0 OF PANELS 28
ADAMS
MODULE DIMENSIONS=62.6"x 41.5"=18.04 SF STRUCTURAL ^�,+L3.'�:X.n�_— AREA COVERED(SO.FT.) 489.04
ROOF DESCRIPTION 9No.49748
AVG.LOAD PER CONNECTION POINT(LBS) 18,78 REVISIONS
ROOF TYPE-COMP SHINGLE ROOF o/STEPS Expir.06/30/2020 WEIGHT PER SO.FT.OF SOLAR ARRAY
TOTAL ROOF AREA=1240.43 /ONAL Structural RevlaW (PSF) 2.50
and Approval Only TOTAL WEIGHT OF MODULES 1051.06
469.04/1240.43=38%OF ROOF PP Y
FACE AREA COVERED BY ARRAY (E) BACK YARD For penetration spacing and additional TOTAL WEIGHT OF OPTIMIZERS 54.00
attachment information see sheet 5-1 TOTAL WEIGHT OF RACKING COMPONENTS 57.30 REVOLU�:UM
TOTAL SYSTEM WEIGHT(LBS) 1172.98
Installers to verify rafter size,spacing and unsupported spans, TOTAL RAIL LENGTH(FT.) 117
and notify E.O.R.of any discrepancies before proceeding.
90
S,OF I T-17 CR-48 SHARED RAILS(188 18
TOTAL RAIL LENGTH FIELD OM 221.33
- PIPE ON ROOF(BACKSIDE) #OF CR48 RAIL SPLICES 5 CONTRACTOR INFORMATION
ROOF#4 TOTAL#OF END-CLAMPS4 EVOLUSUN MASSACHUSETTS
TILT-40• 2'-0" W"
AZIM.-250° --10'-6" '-7" TOTAL#OF L-FOOT ASSEMBLIES 70 "oar" .Ga
u REc mem
ROOF#1 DATE:11/08/!010
-- _-- TILTPROJECT NAME
. 70'
F.
BRADLEY LEVAY III
---- -- ----- ---------- _ MPTORMA01002
_ NORTHAPHONE:
EMAIL:
_________________ JOBt.MA02-20-0028
-- --- - APN NO:—
o --- ---- __ WRING INArnc -- --- --- -------- ci --
0
ED b ---- -- --- 7 ---- ----- ---- ----- --- -- ------- o b PROJECT DETAIL
---- --- ----- -- ----- --- -- -- ----- --- --- ------- • 8.84IKWSTC
w ---- --- --- --- ----- -- -- -------------------------- 7.6 KW AC
11I
-_--_--- ---_-_---_- ------
7K
�L
ENGINEERING APPROVAL
I ________
_______ IN)JUNCTION BOX 4 ' "
-------- SIDEWALL RUN
-- (N)SOLAREDGE SE76WH-US
------ (240)INVERTER
I
I I I __ ________ ______ (N)AC DISCONNECT m
ROOF#a m i i i 1 -------------------- - (N)SMART METER N
TILT-40° I
-----------------
- -------- ----- (N)AC DISCONNECT
AZIM.-250° I I I I ____ _____ (E)UTILITY METER
ROOF#2 I PANASONIC:
TILT-40• J�4-11w 1Q$w •-�w -1w -,w �-0 ,$w dD VBHN340SA17 SHEET NAME
AZIM.-1Ba• ROOF PLAN 8r
_ 2'-11"2'-4" LEGEND
(26)OPTIMIZER MODULES
(ROOF#1,#2.#3) (N)LINE SIDE TAP 7 ■ -JUNCTION BOX — — -RAFTER -
(70)PVATTACHMENT(ROOF#1,#2,#3) M -UTILITY METER �� -r EMT CONDUIT SHEETSIZE
( SOLAR PANELS (E)200AMP MAIN SERVICE PANEL
(N)CR 48 SHARED RAIL TYP. — (ROOF#1,#2,03) � -MAIN SERVICE PANEL o -ROOF OBSTRUCTIONANSI B
INV -INVERTER --EXTERIOR CONDUIT Ll 1"X 17"
1 ROOF PLAN &MODULES 2XS RAFTER 016.O.C. -AC DISCONNECT ® -CHIMNEY SHEET NUMBER
PV-2 SCALE.1/8"=1-0" (E) FRONT YARD LST -UNE SIDE TAP SM -SMART METER PV-2
CONSTRUCTION NOTES PROJECT MANAGER
IAN CLIFFORD
1.) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO
INITIATING CONSTRUCTION.
2.) CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION
DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. REVISION$
3.) ALL EQUIPMENT SHALL BE LISTED BY U.L.(OR EQUAL)AND LISTED FOR 1°f10N °Ah "�
ITS SPECIFIC APPLICATION.
4.) ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT
IS INSTALLED.
5.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
18"MAX PV MODULE TYR MANUFACTURER'S INSTALLATION INSTRUCTIONS. REVOLU(Sum
6.) ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND
4'-0" - - - RAFTERS SHALL BE RESTRICTED TO QUALIFIED PERSONNEL.
7.) ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 VOLTS AND
90°C WET ENVIRONMENT,UNLESS OTHERWISE NOTED.
—1'-4^ 8.) WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE
NOT SPECIFIED,CONTRACTOR SHALL SIZE THEM ACCORDING TO CONTRACTOR INFORMATION
APPLICABLE CODES. EVOLUSUN MASSACHUSETTS
9.) PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE
COPPER G.E.C.PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION
SHEET.
1' II I III 10) G.E.C.PV MODULE RACKING VIA WEEB LUG,LISCO GBL-4DBAIL SHALL BE TLLAYDEN LUGD TO ,ARE COPPER p�n �
OR QUIVLENT LISTED
LUG. DATE:11A)SM19
11.) GROUNDING ELECTRODE CONDUCTOR(G.E.C.)SHALL BE CONTINUOUS PROJECT NAME
AND/OR IRREVERSIBLY SPLICEDfWELDED.
12.)ALL JUNCTION BOXES,COMBINER BOXES,AND DISCONNECTS SHALL BRADLEY LEVAY III
L-FOOT BE INSTALLED IN AN ACCESSIBLE LOCATION. 28 SYLVAN LN
FLASHING 13.) ROOF ACCESS POINTS SHALL BE AT A STRONG POINT ON THE NORTHAMPTON,MA01052
BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDERS OVER EXTERIOR PHONE:
RACKING RAIL WALL OPENINGS. EMAIL
JOBS:MA02-20-002$
1 MOUNTING PLAN VIEW 14.)WORKING SPACE AROUND ELECTRIAL EQUPMENT SHALL COMPLY WITH APN NO:—
NEC 110.26 --
PV-3 SCALE:NTS PROJECT DETAIL
8.84 KW STC
SEE(3/PV-3)FOR 7.8 KW AC
MID CLAMP
ENLARGED VIEW
ENGINEERING APPROVAL
CR 48 SHARED RAIL EVEREST L-FOOT
PV MODULE
ALUMINIUM
N ROOF6 FLASHING
COMPO`'1t1O 16"O G LAG SCREW,HEX (E)COMP
HEAD,5/16"X 4", SHINGLE ROOF
�F tER 18-SSS
(A OFAI4
SHEET NAME
JAMES A.
ym 11/20/2019 MO
&
STRUCTURAL - �3 .t.x_ POC DETAIL
N0.49748
Expir.06/30/2020 PV QUICKMOUNT STRUCTURAL SCREW, SHEET 6Ig
/pNAI ' Structural Review CLASSIC COMP MOUNT QMPV,T-30 HEX ANSI B
and Approval Only WASHER HEAD,5/16"X I 1"X 1 7"
2 MOUNTING METHOD For penetration spacing and additional 3 MOUNTING METHOD 4-17',16-8ss $MEET NUMBER
PV-3 SCALE:NTS attachment information see sheet 5-1 PV-3 SCALE:NTS PV-3
r
ARRAY CONFIGURATION PV MODULE SPECIFICATIONS INVERTER SPECIFICATIONS POWER OPTIMIZER SPECIFICATIONS WIRE AND CONDUIT SCHEDULE AC SYSTEM SUMMARY PROJECT MANAGER
NtlINAL wSTFJ1 v0.TA(E: 2<E VQTE AC
SYSTEM:e.e1 KWeTC,7.0 KW AC MQ)13 N0 PANAEWX:'.ViSDQn7 YDDallo.raRATELxNE:EE7Eaow4 YODELra fqM®OE'P�0 COND COND COND OND d10 g
COND ��T��K'1%O 32ALAN CUFFORD
TOTAL PV MODULE CITY:20 vaABR NTNG:7E IOVAc MAX INPUT PONFR:4110w
TAG
Ow @ TYPE OTD ONO SIZE WULOURREIR PFJREM E(q(11: 40.00A
DIMENSIONS:321MI.M1.1 NCH MOM-VOLTAGE:M MAX VOC:M V
IIJVER7ER ID.S MIH YODl1LE PwATRO ETC.fOW YAX OIJTMCIT CURPEM:3xA OUTPUT CURRENT:ISA pC1 LSTIIINO AMA3H0 RI4MRE 1 ;AVAW �-AUT
7A VOC lOPB4CRCUIT VOLTAGE):71.3 V MCNEIGHEDEFFICENLY:M OUTPUT VOLTAGE:SOVOC2 4 AVAM10 TMVI-2 1 REVI&ONS
NPOVAROONSTQ am VYP(MAJ4PONER VOLTAGE):M.7 V YNOMUY OCVOLTAGE:4MV MIN.STRING LEMONT:a DESCRIPTION DATEMODUIETOTNOTY M RIC(SNORTCRCIIR OIRREN�:O.tfA MVYERIER GIANTRY:1 MMX.STRING LEMONT:20AO7 f AV1pR TIRNI-I 1
OCAC RATIO 1.13 WP(YA%p°NER CURRENT):6.7A I MAX STRING POVAC am
STRING STY: 1 PV SYSTEM MNOMUMI VOLTAGE CALCULATION PER NEC 090.7(A)
MIND 11 VOC MAXSOF TEMPERATURE � ��� �
COIOECTIOH X WL X YODULES N CORRECTED OPEN
MAXOPENCIRCUTVOLTAOE 4M FACTOR SERIES CIRCIIRVOLTAOE
MAX SHORT CIRCUIT CURRENT t0A N X 71.5 %1. Slti IrRI•n•rr
OPERATING CURRENT 15
STRING CITY: 1 I I
M STRING LENGTH 12 ONROOFTOP I INSIDE MSB.1v1T�i BLDG.EXTERIOR bVALL -- +-
MAX OPEN CIRCUTVOLTAGE 400 I I TO UTILITY GRID CONTACTOR INFORMATION
OPERATING VOLTAOE 400
YAX SHORT GROUT CURRENT 1N EVOLU=ra.Uaeea MNNIZOrCwam �B
gAECT Int P2na<FA%
OPERATING CURRENT 15 PgNT OF INTERCONNECTDN • (E)SI-DIRECTIONAL TAP SI +NDnHAwuVEIwRLawTDH
0 UNE DE
INVERTER: O
I PERNEC2<021(BXt)a TH.12(A) 1-PHASE.240V VIM Ea x
SOLAR EDGE SE78WH-US LLBRGTH OF TAP CONDUCTORS n m
OUTPUT:240 VAC,32A I SH/ALLNOI"MED1pFT
99.0%CEC WEIGHTED EFFICIENCY _ _____________
STRING 1:(1)PV MODULE PER OPTIMIZER NEMA 3R,UL LISTED,INTERNAL GFDI r DATE:1,MSM9
ITC7 I I ! INSIDE BASEMEN
(14)OPTIMIZERS CONNECTED IN SERIES a AFCI PROJECT NAME
4.70 KW STC TOTAL OC2 UNGROUNDED,TRANSFORMERLESS
(N6 JUNCTION BOX AC DISCONNECT:
S°0 VDC,NEMA 3lX i M AC1 2401.00M1P FUSED ACI BRADLEY LEVAY III
LISTED , NEMA 3R,UL LISTED
________________ i 0 0 o N Lt i UNE SIDE TOP I (E)MAIN BREAI�R TO 26 SYLVAN LN
AC DISCONNECT: NCUSE24DV,25DAGP NORTHAMPTON,MA01062
24CV,60AMP Lt L, PHONE:
NONIUSED (E)MAIN SERVICE EMAIL
O O O L;
PANEL,1
LLIL.,
NEMA 3R,UL LISTED N •N MUtRAY-PN.3-W. JOSE'.MA02-20-OM
-- I L- ACt SMART F_ IG G 20DARATED,240/,2P APNNO-N h x 1 --
_--------- - DC1 I - a - o i G -'� G G I Act _ METER i PROJECT DETAIL
L, t2 N G mANGMMAIN 6.64 KW STC
I I BONDING JUMPER 7.6KWAC
STRING 2:(1)PV MODULE PER OPTIMIZER I 1s
(12)OPTIMIZERS CONNECTED IN SERIES L
4.06 KW STC TOTAL - _ Oo I ENGINEERING APPROVAL
- -
NEUTRAL CONDUCTOIR
MAV BE OMITTED FIR
DISPONNECT OR MAY i
ASS THROUGH I _
L I L-7-1
EU CTTING ROGE GROUNDING
SYSTEM
LOAD 810E BOTTOM I iRREVERSABLE
CONNECTION TO G.E.0
AMPACITY FORAC
CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY AMPACRY CHECK 01 DISCONNECT
CONDUCTORS DISCONNECT CONDUCTORS
TM CIRCUIT ORIGIN CIRCUIT AMPACINO ppTSmR 0OF MAX MAX MAX
DEETIATM MATERNAL TFAIP' 30'C PER OUTPUT X PARALLEL CURREMPER X 12MPO _ CURRENT CURRENT <CONDUCTOR CONDUCTORS Mrs.<Y
RATING SIZE H0.13(BX1R CURRENT STRIMO6 EMAWM EMAO)Xt) PER PER AMPACITY AMPACITY 4
SMIWI) MOAO9(1) SSAMPS OEMTE PER SHEET NAME
DC7 PVSTRMO JUNCTION DOX COPPER 4r AWOS10 40 AMPS 151) x 1 15.0 AMPS X 170 . WE 10.75 AMPS< 40 AMPS 310.150(3W ELECTRICAL LINE
WAN,X A•`A DIAGRAM
002 JUNCTION BOx INVERTER COPPER 90' MV0M70 40 NAP& 15.0 X 1 15.0 AMPS x I." • WE 10.75 AMPS< 40 NIPS 44AX'94")•4173A•0A0
SHEET SIZE
CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY AMPACITY CHECK#1 CORRECTED AMPACITY CALCULATION AMPACITY CHECK 02 ANSI B
CIRCUIT CIRCUIT MAX MAX NA%
TM AMPACT'0 INVERTER MAX CONDUIT DENTED DENTED N
ORIGIN DESTINATION MATERIAL TEMP' TRADE f0'CPEI1 OUTPUT X SW CURRENTPER X I25%PER CURRENT CURRENT CONDUCTOR CONDUCTOR X TEMP X FILL CONDUCTOR CURRENT < CONDUCTOR �� X 17"
MIND S� 31O.INeI(1R CURRENT IMVEIITERd SMA(AX3) EMAO7X1)• PER P!R < AM
AM
DENTE DENTE AMPACITY PER AMPACITY
SIO E(RTX7) SM.E(BX1) SMOA(BXD SHEET NUMBER
ACI INVERTER YN PANEL E COPPER MO' ANNA M MMP& - X 1 3x.0 AM_ X 170 40-00 40-00/IMlS s M AAMP& S0 X 0.34 - tlp • 51.70 4°.00 AMM < 01.70 AYPo
PV-4
PROJECT MANAGER
h IAN CLIFFORD
DIRECT CURRENT WANING:PHOTOVOLTAIC
PHOTOVOLTAIC POWER SOURCE
ELECTRICAL SHOCK HAZARD •POWER SOURCEREVISIONS
DESCRIPRON DAIS REV
REQ'BY:NEC 690.31(G)(3)
TERMINALS ON BOTH LINE AND MAXIMUM VOLTAGE: 480 VDC APPLY TO:
LOAD SIDES MAY BE ENERGIZED DC WIRING CONDUCTORS OR ANY
IN THE OPEN POSITION ENLOSURE CONTAINING DC WIRING,
MAX CIRCUIT CURRENT: 30 AMPS SPACING SHALL BE NO MORE THAN 10 FEET
R AtJM
REQ'BY:NEC 690.53
APPLY T0:
AC DISCONNECTS INTERIOR AND EXTERIOR REQ'BY:NEC 690.53(1-3) n
APPLY TO: CONTRACTOR INFORMATION
INVERTER AND ANY DC DISCONNECT LUSUN MASSACHUSETTS
nomea".Ix Rmme.ml�
aREcr Ps+_mAee•Nc
S EM E
ID SHUT- PHOTOVOLTAIC
� �• •- DATE 71NYt01•
DISCONNECT_._ . • PROJECTNAME
REQ'BY:NEC 690.56(C) I 1 BRADLEY LEVAY III
TURN RAPID SHUTDOWN APPLY TO: 26 SYLVAN LN
SWITCH TO THE NORTHAMHONE A 01002
own.�R c INVERTER NEXT TO DC SHUTOFF IF RATED AC OUTPUT CURRENT: 40.00 AMPS PHONE:
"OFF"POSITION TO
ST INVERTER IS INSTALLED OUTSIDE, EMAIL
SHUT DOWN PV SYSTEM OTHERWISE APPLY TO MAIN AC DISCONNECT NOMINAL OPERATING AC VOLTAGE: 240 VAC JOB•MA02-20-0020
AND REDUCE J
SHOCK HAZARD APN N0=—
IN THE ARRAY PROJECT DETAIL
REQ'BY:NEC 690.54
8.81 KW STC
APPLY TO: 7.e KW AC
AC DISCONNECT AND LABEL VOLTAGE AND
REQ'BY:NEC 690.56 C 1 A CURRENT WITH PERMANENT MARKER ENGINEERING APPROVAL
2
APPLY T0:
INVERTER ONLY OR NO MORE
THAN 3 FEET FROM INVERTER
DUAL POWER SUPPLY
SOURCES:UTILITY GRID SOLAR ELECTRIC CIRCUIT
BREAKER IS BACKFED
AND PV SOLAR ELECTRIC
TRUN OFF PHOTOVOLTAIC AC SYSTEM
DISCONNECT PRIOR TO REQ'BY:NEC 705.12 B 3-4 9
WORKING INSIDE PANEL REQ'BY:NEC 705.12(B)(3.4) SHEET NAME o APPLY TO: PLACARDS
TO BREAKER OR AREA LABELING
APPLY T0: BREAKER SUPPLYING POWER TO
CIRCUIT LOAD CENTER,MAIN
SERVICE PANEL AND METER INVERTER AND OR 2 CIRCUIT LOAD
REQ'BY:NEC 690.54 CENTER SHEET
SOCKET ANSISI B B
APPLY TO:
MAIN SERVICE PANEL AND METER SOCKET
SHEET NUMBER
PV-5
ROOF DESCRIPTION PROJECT MANAGER
IAN CLIFFORD
ROOF l� AZIMUTH
t1 40• TO•
$2 40• 1Q0• REVISIONS
WE RIPDDN DAIS REV
4p 40• 250•
u 4D• M.
REVOLUIstBIBl
CONTRACTOR INFORMATION
REVOL MASSACHUSETTS
m,no eev ruwµol ex w„
ecr ile,n7 mee rui
nwwRevoww
DAT A IM11 018
PROJECT NAME
BRADLEY LEVAY 111
26 SYLVAN LN
NORTHAMPTON,MA01082
PHONE:
EMAIL:
JOB,MA02-20-0020
APN NO:—
PROJECT DETAIL
8.84 KW STC
T.S KWAC
ENGINEERING APPROVAL
SHEET NAME
LAYOUT
MAP
SHEET SIZE
ANSI B
11"X 17'
SHEET NUMBER
PV-6
PROJECT MANAGER
IAN CLIFFORD
I
H 1 T. + Po ft H 1 T. + REVISIONS
hrotowN4k MWwle Mim,rduk Mduk OEaCRIPrION WTE REV
N340/N335 N340/N335 PRELIMINARY
Panasonic s unique heterolunct]on technology uses uttm-thin _'"`OtlMeX11 w.Wa•ry REVOLU�SUN
amorphous silicon layers.These thin dual Layers reduce losses,
,esuiting in higher energy output than conventional panels. • '""'�'°O-
x.wa"..w...
- --ANCONTRACTOR INFORMATION
r,•nwwc«a.an nw�,. e•n.-, .a•wee
r«www c«•wx.,w, ono. .nnvrc
LUSUN MASSACHUSETTS
r .•..s»+..w.o- ..,.... n]ws. • >nrro wwfw"tan me min
..ec «.s< f wr.r see.rf IN—A EnlEmeuaLNc.o".
� �vT t.•f,.�e", }}•. }25}] n'�-�Qxs rM REO n}n]}
..�,_.......,,« xwwk a.„w. •oa � ww.v.REwWM1N.cowV
® DATE:11108/2019
"•'"”'*"f"'�"fe e0w PROJECT NAME
..-.�. �„.w.wi.w,..r.i .roue•
AManced bitaciat cell designed for increased energy output __ _ _. BRADLEY LEVAY III
The cell utilizes sunlight reflected back from the rear side26 SYLVAN LN
material which captures more light and converted into energy. ea NORTHAMPTON,I 01062
PHONE:
MAL
•www,wswv- uwiviw u. ; � JO&9:MA02-20-0026
rawA °`► o.r.,mx..w.r..e. .eewz•.,.mem,-. J��yy]^ �...r...
•.. 'r -"` ore..+,. wnnc.wc•a .�� _ PROJECT DETAIL
w roue �'ONV-wL ..,• •w,•rw*«G']
8.84 KW STC
Our competitive advantages °-"^�'° ,, ,,_ 7.6 KW AC
».,,.,..
• as wa«k,a
k
High at HighWarranty-
A.
• ENGINEERING APPROVAL
b ry 9 Temperatures 25 Year Product and Performance Wrnnly'
Aslemperaturc increases,H lT"continues to Industry leading 25 year product workmanship en«` our/4nERCt o,mxawAH(L
1� perlormat high levels due to the industry leading and performance warranty is backed by a century " b `"' iMp`" t• -
temperature coefficient of-0.258%/-C.No other old company Panasonic.Power output is
module even comes close to our temperature guaranteed to 90 76%after 25 years,far greater
characteristia.That means more energy than other I.-Den-
throughout the day.
ompaniesthroughouttheday. o"nwi•].,,..•.,: .ew wirrr•.wcw•c� _- _
xY f/•'r w,n'wi•,w �"ar,,,nerx"•yelhVe � ..
DuaUty and Reli.1:14 Higher Efficiency 20.3%
OPanasonicsv m-t integration,21 years of Enables higher power output and greater energy �i.wa co-i.•x.. }msc rr�c 19pe�ul Lc
experience manufacturing HIT'and 20 intern yields.HIT"promdes maximum production for your ]]"]
tests beyond those mandated by current limited roof space. rr wa.w,^fo,•e.,.osov s..,� 'ws • • w • w • w •
standards proides extreme quality assurance.
Lowndation Enhanced Frame Desi n .. �,„ x« •n.c ...»..«.
HIT-DN--ttype'cells result in extremely Low Light G� Anew GOmm frame increases durability and
Induced Degradation 1-10)and zero Potential L strength.being able to handle loads of up to 5400Pa. muu*xwi R•e••'s's + rs•o-^.,«ro a^a,w.
Induced Degradation lPIDI which supports Also,the water drainage system gives rain water ^^',i",,,,,,,,„,_„„»,,,,,"w,,,,,,,,•„-„,,,,�,,,,„,,,„» SHEET NAME
rebabtllty and longevity.This technology reduces and snow melt a place to go.reducing water stains ”" °' ”' "••'""�"`”'- MODULE
annual degradation to 0.26%compare to 0.70% and soiling.Less dirt on the module means more SPECIFICATION
in comentional panels.guaranteeing more power sunlight getting through to generate power.
for the long haul.
+^«+ SHEET SIZE
ANSI B
11"X 17"
SHEET NUMBER
PV-7
PROJECT MANAGER
AN CLIFFORD
I Single Phase Inverter
Wit HD-Wave Technology for North America REVISIONS
SE300OH-US/SE380OH-US/SE5000H-US/SE6000H-US/ 0E90"°"°" DATE
Single Phase Inverter Z SE760OH-US/SE10WOH-US/SE1140OH-US
with HD-Wave Technology rCn °"""' 3�x1 :4J •�" - �• _ REVOLUTANW
3L'Od_06v 000.106 gOm•Dxw
IN
for North America T "°�".A°°"'°"a' " ' '�=�° "•1°6Y 6�' WIXI14MZ M
SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/ "D.161)
Af.!17xr WlA96 Mn.-NGm.M;, w«
SE760OH-US/SE1000OH-US/SEI 140OH-US '' 91
M Aifawwxrlw",ruh 59.3 6D WN.5 CONTRACTOR INFORMATION
Mtww.Ca".N"n Cour
2S .. f_ 475 A
�1+ nU3U�N MASSACHUSETTS
CM1wu•l'JPV •3 A n[er.ireall rAx
w
L^ M1"R9rtvc Awa"�w.cwwAr
v , UIIH Mav7w419Mw9gEGntMlt
• lar 0 fM,Acyn_a�wil.-x•'guzble W.
RYCUT DATE:11)(111i
M.ewr•[C Are.d.+7v -a� Pio +3c0 6650 w PROJECT NAME
ANmvn LL Me•a.:Oev - Pi0 6500 V
BRADLEY LEVAY III
•••• ••••
30D ft26 SYLVAN LN
. 6av1d 0i I.pl xe.4
• Ma,nnn+I,pt Cu�wr p:arv. •: :0 21 X, - NORTHA PHONE:MA 01062
e PHONE:
• • AIe•r,4r.11g6Curaq b;OeV - 0! 27 Alk EMAIL
_.i t •, Mtr 1prtsl�r autcw•n 45 Aec JOBW MA02-20-MO
• • R,.pfl pgAllylwpRxw % APN NO:—
e � • � —.N.kV M,6.Tn Urechn fO�•SwWReip --
1..ea,E1xwm P A2 h PROJECT DETAIL
4§•N0
rn',a E4uw"1 9Y sasexw 6.84KWSTC
e e • • -P1na cw•nc•> 7.6 KW AC
W W ADDITIONAL FEATURES
RS445 Elr.Nt r9be We Glint WptldW1 ENGINEERING APPROVAL
ox—,:,
Optimized installation with HD-Wave technology Au an xRap051—n x-AC Go N-0
STANDARD COMPLIANCE
SYr'r U1741 IV'41 SA L'L•936 CSA C22 2 C-1i.00 aa"tl3q!a 1LL M-01
I Specifically designed to work with I Extremely small u"Cunr _vtw.lrn W15a 1N.'t RW.N.N.
power optimizers 6— KC 1.u Ct.•6
I Record-breaking efficiency I Built-in module-level monitoring MWALIATION SPECIFICATIONS
K G.1Qit COmu'Sit: <4,� 3l4'rt.nnun!Nfi ANG 3fr nwMrun(NJ ANG
R
I Fixed voltage inverter for longer strings I Outdoor and indoor installation oC Reu c. S. •oS it 1,2
•n0.!W6 AWG 3N'.Nr 11.3 ftW,Nb ANG
D.nwN"rR N�011.kry 5W¢� . _
Integrated arc fault protection and rapid shutdown for/ Optional:Revenue grade data,ANSI C7220 INAWO7 r11N 6.be 1450.310.01 213,N6,13(40+370.1%
NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) W.W u1's»'.1 swlr^ 1 31,114 M2,n o Neer 116
bane .5 '50 AA SHEET NAME
UL1741 SA certified,for CPUC Rule 21 grid c.9q Noy c_
compliance Nur-251-W't-01I.4aC Wkw iINVERTER
N�wl�Rs g NfMAJ II W wa•sr.ns wm SPECIFICATION
solar ,., �',vum nmw.swee:w.J,.w o., SHEET SIZE
solaredge.com • � :�.,r... .�.N ",».,.,.ryr:mw..,,...Yw..-..M�.>n,,.»1.N,s..v� ANSI B
NX.
SHEET NUMBER
PV-8
PROJECT MANAGER
IAN CLIFFORD
/ Power Optimizer
-� For North America
REVISIONS
Power Optimizer O P320/P340/P370/P400/P405/P505 WMW REY
For North America C
P320/P340/P370/P400/P405/P505 t7 REVL
M INPUT
Sly ., of Nk
Adc CONTRACTOR INFORMATION
--—- - - _-
171 Adc REVOLUSUN MASSACHUSETTS
u_
__ r m�+bmesaw"perme.mn
ti94 a ,wRN.vBUE�alluMarbl
am
_ "w.l.9cvowew.cwew
OUTPU7 DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
DATE:77Afl2019
OUTPUT DURING STANDBY( WOt OPTIMMER DISCONNECTED FROM SOLAREDGE INVERTER ORSODAREDGE Ns PROJECT NAME
111,I01ERDER OFF)
N aM �
BRADLEY LEVAY III
CE
M STANDARD COMPUAN28 SYLVAN LN
s.,.. _ NORTHAMPTON,MA D1O82
PHONE:
EMAIL:
INSTALLATION spwFICATIONS JOBS:MA02.20.0028
APN NO:—
rv.w"
.a�veww".•wo.: a,.,.naw,.anw"n.0 ana rn�er"Nafe,MiVY.
PROJECT DETAIL
P:nnw"9tW atvH W.Kisl:SlS t+b•�� 94+K3+f5f/ WSK!s ass- '2us Wts S9/ rolriln
v.ae1J SJaatsl9 s.Ixasat.E 0.66 KW STC
nn5aoy J Nol1A 61SO +061/1.+ le 7.0 KWAC
'roa CaRaaa MLa'
clI,WN tV9ar Cr:— _v -A..t MU
wry.,s w�R rr 0.95/30 IJ/T� nik ENGINEERING APPROVAL
unu wire re a ia/052 m IR
Cywatn9 iirora;.e -a0..m/U..195 'l/T
PV power optimization at the module-level «,awn YM/NEMALP
9Maw.IN�WAy o•wo r
+n.a s._p..w a«..,�,w w,e«.ew M.we.,.u.•rc.aw..0
/ Specifically designed to work with SolarEdge I Fast installation with a single boR b»..�'""•^•,:n� .w+iwar"n°"�
inverters
/ Next generation maintenance with module-
I Up to 25%more energy level monitoring
95.tl, 3a0,'3711
Mmnum Stung lwptli ax y 8 10 b
I Superior efficiency(99.5%) / Meets NEC requirements for arc fault *" WS/uses 6 9 u
protection(AFCO and Photovoltaic Rapid "A°"^iun5tn^"""`^^ 25 n -
/ Mitigates all types of module mismatch losses, Shutdown System(PVRSS) ;m,,mm—
from manufacturing tolerance to partial 5EwiiP.O-Allo ;no 0000 4:1v w SHEET NAME
shading / Module-level voltage shutdown for installer A.
OPTIMIZER
and firefighter safety �a�uxmwn
Flexible system design for maximum space .,« ••y,a.d .tt,Ha+..ya ,�,...wl, rRF�..w+�..a,,.r.9,�.ou� SPECIFICATION
utilization
i♦,.rq wr a"�•- �M�:�+W vub.-.i;w��wrtt Ml w. in W�.v..nwrn
.sn..vvxa+2w%r..w.�.i...".u,..r .,ww.:.ns••M.•�,y,r..u,.«..„.rw�cnr.m2r r•,..�.�w,ru:n�s..a e.
SHEET SIZE
b rclraLLY.aF d 34nhtrAv.nl'rN axJflll b is eWrrl,u MY,q r�5,a6]"r t«Wry a'vn r Nryr•eanW W 4,n•mr,a�.w.5.fw v«roA06b11RAiR�I�
.a.�.,��.,m..•.�r.�.,EN�..w..^.n..,.a"w..�o� ANSI B
Solaredge.corr solar T 11"X17"
orr+►�w+wrr�i.' ..••••" ."r.,.w.+,.a'.w iw.a'�aa,e w«c+.,a. CE obw SHEET NUMBER
PV-9
PROJECT MANAGER
IAN CLIFFORD
REVISIONS
� OEBCRiPrKN DATE REV
Mounting systems for solar technology Mounting systems for solar technology
��solar tystemy' talar t
Shared Rail for Pitched Roof: REVOLU(SW
—:n—;.;tea
Fast vmpie insta'laoon
No dn!h rig,no bonding jumpers
Pie-assembed unrvelsel module dw0s with CONTRACTOR INFORMATION
mediated bon dug
Robust bond,.ng ra,so,CeS REVOLUSUN MASSACHUSETTS
Low PV Count
mer nm arzna e,a
A60 Compaub,ew-th hie,00fsuvng Nsrr" 1N0"T" iNCTON�
ava,lab,e roof hooks u,.. nre,n
UL 2703 LISTED COMPONENTS
DATE.11/08'2018
Ai,Dlmponenls t%eluated Under UL 2703 and encompassed wahh Everest Solar Syslem S UL 2703 Listing shown below urn PROJECT NAME
d you seek a UL listed System,only the parts shown m this page are acczptabie.
Crossbil48-S/48/80 Y Bumdy WEEB lug B.0+Hardware BRADLEY LEVAY III
1 28 SYLVAN LN
ateywan,,,, OrBurndyWEERLug 10.3+Hardware NORTHAMPTON,MA01082
rnnh mi!,oa'c amdcaa • All&*wEEe L"M "eepyW og" PHONE
yrtleallCRMlytimEMAIL:
--- - - JOB;,:MA02-20-0028
Rail Connector Set' rs■.s.e L-Foot with Hardware APN NO:—
Mal-9 afurn,en, " Mat—eamrwm --
�mnh m.h.date amdum +.nish ni.,daleaW..
2_ nerdwae s+mnesssuel_ �_--.___ f na,rl.:are..uMns steep PROJECT DETAIL
Structural Rall Connector Set STC
Optional:Array Skirt e e KW
CR 49.5
Mae" � i'mish d aam mien
Mae".aiumrem r�nen mh ax»a0
W lde�lt♦s!freed steel —d—names,steel ENGINEERING APPROVAL
CrossRail Mid Clamp UL2703+Set' EverFlash eComp with Slide Kit
JC 50 mm Mate al nenun.sta Na;steep
Mater N nnnwss steel ..tSn��
rJt CrossRall End Clamp Set Everflash gComp with Slider Kit
30 50 mm McIPWI aumnun.na40 n�ass.tn
Material ttbNe55 S:tel AJW
N,nn s,ae
ASSEMBLY INSTRUCTIONS m,snel�.d.s Q
Y' Optional:Micro Inverter and Optimizer
RESIDENTIAL ROOF SOLUTIONS Mounting Kit"
w 'A,—al slanlese Stas'
CROSSRAIL SHARED RAIL SYSTEM SMEETWWE
ATTACHMENT
®
SPECIFICATION
ILL 2703 Listed System
USA
SHEET SIZE
ANSI B
Materials Required 1111111111111 a 1 15 11e1 X 17"
SHEET NUMBER
PV-10
PROJECT MANAGER
UN CLIFFORD
Im
EverFlash gComp + Slide Kit REVISIONS
oEsaevnaN DATE REV
-� With Quick Mount PV® Elevated Water Seal Technology
► Fast,simple installation that �
with most composition roof typeseS
► Minimal component count resulting in a
li*i lower overall installation cost
ly �
�S��Q� ► Compatible with CrossRail Shared Rail System CONTRACTOR INFORMATION
11 Fused flute raised 0.3"above the metal fleshing USUN MASSACHUSETTS
to stop water encroachment aa"mA w Ei a"uwma
v.m
DATE:11100=19
PROJECT NAME
Components
BRADLEY LEVAY III
28 SYLVAN LN
NORTHAMPTON,MA 01082
PHONE:
EMAIL:
JOB":MA02-2(-0028
APN NO
--
iS`� PROJECT DETAIL
wt26 .i 8.84 KWSTC
7.8 KW AC
Tools Required
ENGINEERING APPROVAL
t I
► 112"socket(for lag bolt)
EverFlash gComp EverFlash L-Foot `5x16"Lag Bolt Slide Kit ► 7/32"aircraft extention
Flashing 9x12" and Hardware
Material.sralniess Material,aluminum ► Measuring tape
-material,aluminum Material:aluminum steel
FMnsh:mill,dark ants stainless steel ► Cordless drill
Finish:moil,dark
► Torque wrench(0-50 ft/7b)
► Roofing bar
SHEET NAME
► Sealant ATTACHMENT
R E V4 LU(S U N. . String line SPECIFICATION
SHEET SIZE
cleaner, smarter. solar. N. ANSI B
11"X 17"
(701)9480498 1 1 MwV,A—io.SURE A.6.1rVIM.MA OHO
SHEETNUMBER
PV-11
1.Installers to verify rafter size,spacing and sloped spans,and notify the E.O.R of any discrepancies before proceeding.
r I—�`f RIDGE T T 2 Any rotted or damaged rafters shall be replaced prior to proceeding.
3.As a precaution,old or wet snow should be removed from the roof,if the snow builds up to 18"or more.
7`4F
HORIZ.SPACING 1MAK AVERAGE SLOP�p SP
HORIZ.SPACM
COLLAR TIES
SUPPORTS WHERE APPIES
ROOF I (NO BEARING WALL LOW) I I
SLOPE
( p
INTERIOR WALLS
(LOCATION MAY VARY)
` RAFTERfrRUSS CHORD SEE OVERALL SPAN
LANDSCAPE ROOF STRUCTURAL INFO PORTRAIT I_L
"SPACING NOT TO EXCEED MANUFACTURER'S SPECIFICATIONS ROOF ACCESS-' DETAIL 2 ROOF TYPE -COLLAR TIES
DETAIL 1 STAGGERED ATTACHMENTS LAYOUT NTS SEE ARCH
4 STRUCTURAL INFORMATION
SRC Job Id: 25672
Calling Type: 1/2 gyp.Bd.
Collar Tle Space: 48
ROOF RAFTERS OR Coverage%: 50
SiRUCRRRAL MEMBERS
Frame Size: 2x8(916
Ground Snow(psf): 40
Sloped Roof Snow Load(psf): 19.3
�ZN OF?,f Leg Screw Diameter(In): 5/16
�A S Lag Screw Embedment(In): 2.5
Overall Span(ft): 40
JAMES A. PV Orientation: Both
MOR¢ONTA-DeTANCE vERT�ca DISTANCE ADAMS
BETWEEN STANDOFFS BETWEEN SrANDOFFS PV Weight of: 3
STANDOFFS ARE BOLTED INTO ROOF STRUCTURAL y g IP )
RAFTERS OR STRUCTURAL MEMBER %n d97<$ Rafter Sloped Span(ft): 21
TYPICAL RAIL-LESS SYSTEM ,O\y v �. Rall System: RallLass
'G�CIST E9' F� Roofing Type: Comp.Shingle
ATTACHMENT �ONAL ENG\ Roof Mean Height(ft): 20
PV MODULE PV PANEL
Root Slope(degrees): 40
RCOF SHTG
ROOF SHTG. moi% Root Type: COIIarTIM
G�/� Jame@Digitally Signed by Sloped Calling?: No
RAFTE
JamM A.Adams,S.E.
Date:20101 9.11.2011:43:45-0800 Standoff Max.Horz.Space(tt): 4
vEa MAX.AVERAGE Standoff Max.Vert.Space(ft): 5.417
M PPG`NG' HORIZ.SPACING Standoff Staggered?: Yes
4 Ft Wind Exposure: C
Wind Speed(mph): 120
This sheet not to be used without permission from
DETAIL(3 FLUSHMOUNT SOLAR-ROOF-CHECKCOM
Current Renewables Engineering DESIGNER: SRC PROJECT NUMBER PROJECT NMIESF65 BRADLEY LEVAY IIISHEET: DATE:
1960 Chicago Ave,Suite D-15 26 SYLVAN LN STRUCTURAL
Riverside CA 92507 USA DRAFTER: SRC LEVAY III NORTHAMPTON MA 01062 DETAILS S-� 11-19-2019