Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
31A-158 (3)
ti BP-2019-1417 79 MAYNARD RD 79 #: COMMONWEALTH OF MASSACHUSETTS GISMap:Block: 3]A- 158 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL 042A) Cate o :New Single Family House BUILDING PERMIT � ry € � Permit# BP-2019-1417 Proiect# JS-2019-002291 Est.Cost: $364000.00 Fee:$2272.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: RONALD BERCUME 001848 Lot Size(sa.ft.): 13416.48 Owner: BAINS REKHA Zomnc: URB(100)/ Applicant: RONALD BERCUME AT: 79 MAYNARD RD Applicant Address: Phone: Insurance: 25 SYLVIA HEIGHTS (413) 374-5050 O SOLE PROPRIETOR HADLEYMA01035 ISSUED ON.6/27/2019 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCTION NEW SFH WITH SMALL. APARTMENT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: n/IC 7���� / Footings: ,,Rough- —e291Rough: moo"' �l / House# Foundation: & //9 n� Driveway Final Final G �< � 'G Final/ ��l- es p Rough Frame: he`.k, W INY(..t4S Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation:D,y, q q Final: Smoke: 34C- Y/7 lel— THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES ANDRE U IONS. ✓ ,` A / Certificate of Occu anc Signature: V FeeType: Bate Paid: Amount: Building 6/27/2019 0:00:00 $2272.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck--Building Commissioner F 0 79 MAYNARD RD EP-2019-0895 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Map: 31 A Lot: 158 ELECTRICAL PERMIT Permit: Electrical Category: WIRE NEW HOME INCLUSING 200 AMP U.G. SERVICE AND ALL LOW VOLTAGE Permit# Electrical PERMISSION IS HEREBY GRANTED TO: Project# JS-2019-002291 Est.Cost: Contractor: License: Fee: $250.00 TOWER ELECTRIC Master Al 8067 Owner: BAINS REKHA Applicant. TOWER ELECTRIC AT: 79 MAYNARD RD Applicant Address Phone Insurance 578 N. Westfield St (413) 530-4343 () C-(413) 789-4111 Liability, BKS1656776093 FEEDING HILLS MA01030 ISSUED ON:6/26/2019 0:00:00 TO PERFORM THE FOLLOWING WORK: WIRE NEW HOME INCLUSING 200 AMP U.G. SERVICE AND ALL LOW VOLTAGE Call In Date: Date Requested Inspection Date/SiEnOff: Reinspect?: Trench/UG: Special Instructions V�dc)t�cl.�n�� Me T��K �S 7- g q-lq R?1 A X q, 1 Rouzh q'd27'1Cl 2� ��4II La- f�il� l' /3/q Q?� �,.—y�//` IDrse�� / lvv,\ x Special Instructions: q� Final SRE Called In: Sip-nature: Fee Type:: Amount: DatePaid Electrical $250.00 6/26/2019 0:00:00 6146 212 Main Street,Phone(413)587-1244,Fax(413)587-1272-Inspector of Wires -Roger Malo MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM GAS FITTING WORK C� CITY �� - MA DATEd),3.7) PERMIT#6 J 1-� 1 JOBSITE ADDRESS I�Q�� OWNERt�) 'S NAME / � GOWNER ADDRESS 5 Sy/(/�G� �IQ,IU- � 1'f 'l/Il/' TEL �I-3 '-R L176 TYPE OR OCCUPANCY TYPE COMMERCIAL EDUCATIONAL RESIDENTIAL✓ PRINT CLEARLY NEW:V RENOVATION: REPLACEMENT: PLANS SUBMITTED: YES NO APPLIANCES-1 FLOORS— 8SM 1 2 3 4 5 6 7 S 9 10 11 12 13 14 BOILER BOOSTER CONVERSION BURNER COOK STOVE DIRECT VENT HEATER DRYER FIREPLACE FRYOLATOR _ FURNACE GENERATOR - - GRILLE INFRARED HEATER LABORATORY COCKS MAKEUP AIR UNIT OVEN Northampton.MA 010f,0: POOL HEATER ROOM/SPACE HEATER ROOF TOP UNIT _ TEST _ UNIT HEATER UNVENTED ROOM HEATER WATER HEATER PP OVE PPROVE OT OTHER -fes /ow ldinU INSURANCE COVERAGE I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL.Ch.142 YES 1 NO I IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY -, OTHER TYPE INDEMNITY BOND OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. _ CHECK ONE ONLY: OWNER AGENT SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information 1 have submitted or entered regarding this application are true and accurate to the best of my knowledge and that all plumbing work and installations performed under the permit issued for this application will be in compliance with all Pertinent pzrovion of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. L : PLUM BER-GAS FITTER NAME ALFRED H.GEORGE LICENSE# 3809 P' SIGNATURE MP MGF v JP JGF LPGI CORPORATION , # 130C PARTNERSHIP # LLC # COMPANY NAME. GEORGE PROPANE, INC. ADDRESS 3 BERKSHIRE TRAIL WEST,PO BOX 102 CITY GOSHEN STATE MA ZIP 01032-0102 TEL 413-268-8360 FAX 413-268-0206 CELL EMAIL mgeorge@georgepropane.com OV-110c. 11 Sw MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM GASFITTING WORK n ti CITY Northampton MA DATE r-8.8.19 PERMIT# alo JOBSITE ADDRESS 79 Maynard Rd OWNER'S NAME Bercume Builders GOWNER ADDRESS r25 Sylvia Heights Hadley MA 01035 TEL 413-374-5050 FAX TYPE OR PRINT OCCUPANCY TYPE COMMERCIAL EDUCATIONAL RESIDENTIAL CLEARLY NEW: RENOVATION: REPLACEMENT: PLANS SUBMITTED: YES NO APPLIANCES 'I FLOORS— BSM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BOILER 1 BOOSTER CONVERSION BURNER COOK STOVE 1 1 DIRECT VENT HEATER DRYER FIREPLACE FRYOLATOR FURNACE GENERATOR GRILLE INFRARED HEATER LABORATORY COCKS MAKEUP AIR UNIT OVEN POOL HEATER ROOM I SPACE HEATER ROOF TOP UNIT TEST SW Ta I UR UNIT HEATERfON N PIRM AM F6 UNVENTED ROOM HEATER APPRC VED--M PR VPD WATER HEATER OTHER INSURANCE COVERAGE have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL.Ch.142 YES NO IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY , OTHER TYPE INDEMNITY BOND OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. CHECK ONE ONLY: OWNER AGENT SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information I have submitted or entered regarding this application are tr a and accurate to the best of my knowledge and that all plumbing work and installations performed under the permit issued for this application will be in co Hance with I Per, ent rovi ion of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. PLUMBER-GASFITTER NAME Gary Stahelski LICENSE# 9621 SIGNATURE MP MGF JP JGF LPGI CORPORATION , # 2617C PARTNERSHIP # LLC # COMPANY NAME: EWS Plumbing&Heating, Inc, ADDRESS 339 Main Street CITY Monson STATE MA ZIP 01057 TEL 413-267-8983 FAX 413-2674523 CELLEMAIL''w ph@comcast.net ROUGH GAS INSPECTION NOTES THIS PAGE FOR INSPECTOR USE ONLY FINAL INSPECTION NOTES Ya No THIS APPLICATION SERVES AS THE PERMIT ❑ ❑ FEE: $ PERMIT# PLAN REVIEW NOTES eev� s � /5' ,o�6as�•Z�s %z� � i1 MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM PLUMBING WORK y CITY Northam tonMA DATE 8/8/19,_ PERMIT# JOBSITE ADDRESS 79 Maynard Rd OWNER'S NAME[Be�rcume Builders POWNER ADDRESS 25 Sylvia Heights Hadley MA 01035 � TEL5413-374-5050 FAX TYPE OR OCCUPANCY TYPE COMMERCIAL EDUCATIONAL 0 RESIDENTIAL PRINT CLEARLY NEW: RENOVATION: ] REPLACEMENT: PLANS SUBMITTED: YES _ NO FIXTURES 1 FLOOR— BSM 1 2 3 8 10 11 12 13 14 BATHTUB 2 _. CROSS CONNECTION DEVICE DEDICATED SPECIAL WASTE SYSTEM DEDICATED GAS/OIL/SAND SYSTEM ` DEDICATED GREASE SYSTEM DEDICATED GRAY WATER SYSTEM F. ' DEDICATED WATER RECYCLE SYSTEM o arlplon. DISHWASHER 1 - DRINKING FOUNTAIN u FOOD DISPOSER 1 1 FLOOR/AREA DRAIN INTERCEPTOR(INTERIOR) KITCHEN SINK LAVATORY -- — 2 5 r ROOF DRAIN _ SHOWER STALL 2 1 i .. SERVICE/MOP SINK TOILET 2 3 URINAL WASHING MACHINE CONNECTION - WATER HEATER ALL TYPES 1 WATER PIPING OTHER INSURANCE COVERAGE: have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL Ch.142. YES NO IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY , OTHER TYPE OF INDEMNITY BOND OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. CHECK ONE ONLY: OWNER AGENT SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information I have submitted or entered regarding this application are true and accurate to the best of my knowledge and that all plumbing work and installations performed under the permit issued for this application will be in tTpliance 0 all Pertinent provision of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. v( . PLUMBER'S NAME GARY STAHELSKI ILICENSE# 9621 SIGNATURE MP JP CORPORATION !A 2617C PARTNERSHIP--#L LLC # COMPANY NAME PLUMBING&HEATING, INC, :�]ADDRESS L339 MAIN STREET CITY MONSON STATE MA ZIP ?01057 -- A TEL 413-267-8983 FAX413-267-4523 CELL I EMAIL EWSPH COMCAST.NET ROUGH PLUMBING INSPECTION NOTES BELOW FOR OFFICE USE ONLY FINAL INSPECTION NOTES Yes No THIS APPLICATION SERVES AS THE PERMIT ❑ ❑ FEE: $ PERMIT A PLAN REVIEW NOTES The Commonwealth of Massachusetts : F.. City of Northampton 11 Certificate 2f Occupancy In accordance with 780 CMR, Section 8110 (Tlte Nintlt Edition of the Massachusetts Residential Building Code) this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Nance of Building of Space Within, Building Owner, or Permit Holder Certificate No. Issued to Ron Bercume BP-2019-1417 Identify property address including street number, name, city or town and county Located at 79 Maynard Rd. Northampton, Hampshire, Massachusetts Use Group Two Family Dwelling Classification(s) This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise,structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate,failure to comply with conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Two Family Dwelling All fire protection and life safety systems must be maintained, and all means of egress must be kept clear Name of Municipal Date of Final Map/Plot. Building Official Kevin Ross Inspection 11/12/2019 Signature of Municipal Date of Building Official Issuance 12/19/2019 31A-158 h � IIIIIIIII x.019 000�5�39 Bk: 13490Pg: 58 Page: 1 of 1 Restrictive Covenant as to Recorded: 12/18/2019 10:04 AM 79 Maynard Road, Northampton, MA 01060 KNOW ALL MEN BY THESE PRESENTS That Rekha Bains, owner of real estate at 79 Maynard Road, Northampton, Massachusetts, hereby covenants that: The basement space at 79 Maynard Road, Northampton, Massachusetts will be used as storage, office, studio or recreation. It will not be used as a bedroom or sleeping space without first obtaining a building permit and meeting all the requirements of the Massachusetts State Building and Health Codes for a newly created bedroom. Executed as a sealed instrument this day of f �f Rekha Bains, Owner C' (State) (County) On this day of �9 before me, the undersigned notary public,ublic, pp 'personally a eared Rekha Bains, proved to me through satisfactory evidence of identification, which was personal knowledge, a driver's license, oath or affirmation of a credible witness, to be the person whose name is signed on the preceding or attached document, and acknowledged to me that she signed it voluntarily for its stated purpose. UaL th " , Notary Public My commission expires: *� ANDREE J. MARINELLI COMMONNotary PUbliC WEALTH OF MASSACHUSETTS My C0 rrNssion Expires August 22, 2025 AnEST::HAlwaREGIBTER r 7 x1G6AY I�illel(lt 2015 IECC i Property Organization HERS Ronald Bercume Noonan Energy Corp Confirmed 79 Maynard Rd 413-427-2423 2019-11-12 Northampton, MA 01060 Paul J. DellaTorre Rating No:0073-0680 RaterID:8776762 Weather:Chicopee, MA Builder Contemporary on Maynard Main Bercume Construction House 0073-0680-C1 Bercume Construct Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings: 59.3 46.2 Above-Grade Walls: 157.5 149.3 Windows and Doors: 287.8 227.7 Basement Walls: 86.2 110.3 Overall UA (Design must be equal or lower): 590.8 533.5 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1.2) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 9.7%. Name Paul J. DellaTorre Signature 2� 7 2, � Organization Noonan Energy Corp Date 19 November 2019 REM/Rate- Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. 0 1985-2018 NORESCO, Boulder, Colorado. 015 IECC Energy Cost Compliance Property Organization HERS Ronald Bercume Noonan Energy Corp Confirmed 79 Maynard Rd 413-427-2423 2019-11-12 Northampton, MA 01060 Paul J. DellaTorre Rating No:0073-0680 RaterID:8776762 Weather:Chicopee, MA Builder Contemporary on Maynard Main Bercume Construction House Annual Energy Cost $/yr 2015 IECC As Designed Heating 2664 2271 Cooling 277 246 Water Heating 360 360 SubTotal- Used to Determine Compliance 3300 2877 Mechanical Ventilation Fan 53 87 Lights Et Appliances (minus MechVent) 1373 1191 Photovoltaics -0 -0 Service Charge 96 96 Total 4822 4252 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 12.8%. Name Paul J. DellaTorre Signature �.' ":l Organization Noonan Energy Corp Date 119 November 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. ©1985-2018 NORESCO, Boulder, Colorado. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 79 Maynard Rd , Northampton , MA by Bercume Construction exceeds the minimum requirements for the 2015 International Energy Conservation Code Building Features Ceiling Flat R-49.0 Duct R-6.0 Sealed Attic: NA Duct Leakage to Outside: 0.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage: 120.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration: Htg: 1231 Clg: 1231 CFM50 Foundation Walls R-10.2 Window U-Value: 0.260, SHGC: 0.280 Exposed Floor NA Heating Fuel-fired air distribution, Propane, 95.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Propane, 0.87 EF, 50.0 Gal. The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 19 November 2019 The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( "ICC"). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 2015 IECC Certificate 79 Maynard Rd , Northampton, MA 01060 Building Envelope Insulation Ceiling R-49.0 Above Grade Walls R-21.0 Foundation Walls R-10.2 Exposed Floor NA Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 1231 Clg: 1231 CFM50 Duct R-6.0 Total Duct Leakage 120.00 CFM @ 25 Pascals Window Data 1.1-Factor SHGC Window 0.260 0.280 Mechanical Equipment HEAT: Fuel-fired air distribution, Propane, 95.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Propane, 0.87 EF, 50.0 Gal. Builder or Design Professional Signature ,�,oics REM/Rate - Residential Energy Analysis and Rating Software 05.7.3 IECC 2015 Energyt Index Property Organization ERI Ronald Bercume Noonan Energy Corp Final 79 Maynard Rd 413-427-2423 Northampton, MA 01060 Paul J. DellaTorre Annual Energy Consumption Rated Home Calculated Rated Home Cost ($/yr) Energy Use (MBTU) Heating 80.6 1999 Cooling 3.2 133 Water Heating 15.1 279 Lights Et Appliances 35.9 1385 Photovoltaics -0.0 .0 Total 1 134.81 3893 Annual Estimates Electric(kWh): 10656 CO2 Emissions(Tons): 12 Propane(Gallons): 1078 Energy Savings ($)**: 2935 *Based on standard operating conditions **Based on the 2015 IECC Energy Rating Index Reference Design Home TARGET ERI: 55 2015 ERI: 52 PASS This home MEETS the 2015 Energy Rating Index requirements of Sections 406.3 and 406.4 of the 2015 IECC for climate zone 5A. This 2015 ERI is calculated per ANSI/RESNET/ICC Standard 301-2014, as published January 2016 with Addenda Aft B. Name Paul J. DellaTorre Signature �`�"�� 7,'' Organization Noonan Energy Corp Date 19 November 2019 L _ Mandatory Requirements 2015 ERI Target PASS Duct Insulation (Ducts outside R-6, inside is R-0) PASS 2009 IECC UA PASS Maximum Fenestration U-factor/SHGC (R402.5) PASS' Duct Testing (2015) PASS Air Leakage (5 ACH50 for CZ1-2, 3 ACH50 for CZ3-8) PASS' Mechanical Ventilation PASS High efficacy lights installed (75%) PASS Hot water pipe insulated to R-3 PASS Mandatory Requirements Checkbox (2015 IECC) PASS Mechanical Ventilation Efficacy PASS Emissions Data Provider Data and Seal Pollution Prevented Carbon Dioxide (CO2) -tons/year 8.4 Noonan Energy Corp. Sulfur Dioxide (SO2) -lbs/year 10.4,18 Robbins Road Nitrogen Oxides (NOx) - lbs/year 18.2 Springfield, MA 01104 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. ©1985-2018 NORESCO, Boulder, Colorado. Home Energy Rating Certificate Property HERS Ronald Bercume Rating Type: Confirmed Certified Energy Rater: Paul J. DeRaTorre 79 Maynard Rd Rating Date: 2019-11-12 Rating Number: 0073-0680 Northampton, MA 01060 Registry ID: 974660065 FEstimated Annual Energy Cost Use MMBtu Cost Percent HERS Index: 52 Efficient Home Comparison: 48% Better Heating 81.8 $2028 53% General Information Cooling 3.0 $126 3% Conditioned Area 4918 sq. ft. House Type Single-family detached Hot Water 15.1 $279 7% Conditioned Volume 45418 cubic ft. Foundation Conditioned basement Lights/Appliances 33.5 $1284 34% Bedrooms 5 Photovoltaics -0.0 $-0 -0% Service Charges $96 3% Mechanical Systems Features 1 Total 133.4 $3813 100% Heating: Fuel-fired air distribution, Propane, 95.0 AFUE. I F Heating: Fuel-fired air distribution, Propane, 95.0 AFUE. L Criteria Cooling: Air conditioner, Electric, 13.0 SEER. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 45.00 CFM25. 2015 IECC UA Compliance Ventilation System Balanced: ERV, 140 cfm, 70.0 watts. 2015 IECC Performance Path Programmable Thermostat Heat=Yes; Cool=Yes Building Shell Features Ceiling Flat R-49.0 Slab R-0.0 Edge, R-0.0 Under Sealed Attic NA Exposed Floor NA Vaulted Ceiling NA Window Type U-Value: 0.260, SHGC: 0.280 Above Grade Watts R-21.0 Infiltration Rate Htg: 1231 Clg: 1231 CFM50 1 Foundation Walls R-10.2 Method Blower door Noonan Energy Corp. Lights and Appliance Features 18 Robbins Road Interior Fluor Lighting (%) 0.0 Range/Oven Fuel Propane Springfield, MA 01104 Interior LED Lighting (%) 100.0 Clothes Dryer Fuel Propane Refrigerator (kWh/yr) 683 Clothes Dryer CEF 4.30 P � a Dishwasher (kWh/yr) 225 Ceiling Fan (cfm/Watt) 79.00 Certified Energy Rater: REM/Rate- Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET HERS Index Certificate HERS$Index 79 Maynard Rd More Energy Northampton,MA 01060 Rater: Paul J. DellaTorre iso Registry ID:974660065 40 Annual Estimates': Existing 130 Elec(kWh): 9893 Prop(Gallons): 1091 Homes ; 120 CO2 emissions(Tons): 11 10 Energy Savings($)'": 5034 Standard 1�� 'Based on standard operating conditions New Home "Based on U.S. DOE designation of a HERS AO 80 Index of 130 as the Typical Existing Home' 70 s0 TAisNome Noonan Energy Corp. 50 52 18 Robbins Road to a0 Springfield,MA 01104 30 20 Zero Ener10This home has been inspected Home and performance tested inlY Less Energy accordance with Chapter 3 of !�t the RESNET standards. wwwresnet.us Cc: BSI-Triforce-support-USA-UD<Idforce-support-USA - ebarrette.com> Subject: FW: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Hi Gabe, We have a job where a bunch of the joists were installed upside down. Please see attachment Dec 10-9-2019 for the ones that are marked. Can you please send us the joists calcs for those joists. You can reply all as I have copied our tech support email. Thanks for your help Matt From: Foucault,Jean-Sebastien Sent: Tuesday,October 15,2019 8:18 AM To: Loiselle,Matt Subject: RE: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Good morning Matt, Could you have Gab to send us all the joist designs from Analyzer that are upside down? Thanks, Jean-Sebastien Foucault 0:800.263.7265 C:819.386.2061 F:819.374.4527 www.oDenioisttriforce.com \'q1TRIF0Ror.E' De: Loiselle,Matt Envoyk: 14 octobre 2019 14:19 A :BSI-Triforce-support-USA-UD Subject: RE: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Good morning Brett, Please fmd the layout and quote attached for the Bercume house,under layout# 19-1057. Let me know if there are any questions or changes.Have a great day. Thanks, Gabe LaBelle Engineered Inside Sales Submit plans&inquires to:plans(dcoastalfp.com p: 800-932-9663 1 d: 603-706-4293 Coastal Forest Products I ivw ..coastalfp.com This message is confidential. It may also be privileged or otherwise protected by work product immunity or other legal rules.If you have received it by mistake,please delete it from your system;you may not copy this message or disclose its contents to anyone. The integrity and security of this message cannot be guaranteed on the Internet. -----Original Message----- From:Brett Sallee<h1aU=@J&adVhQmLg=> Sent:Tuesday,May 14,2019 7:14 AM To: Plans<plans coal com> Cc: Mark Leger<g1h er .coastalb.com> Subject: Fw: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Hello Please do layout+quote for attached house plans. Job name Bercume/Maynard st Northampton Ma. 117/8"tri-force joists for 1st floor only with lvl's for any beams needed. Could you have Gab to send us all the joist designs from Analyzer that are upside down? Thanks, Jean-Sebastien Foucault 0:800.263.7265 C:819.386.2061 F:819.374.4527 www.orenioisttriforce.com "\q kTRIF,OPJ PAOR.CE- 11 aN De: Loiselle. Matt Envove : 14 octobre 2019 14:19 A : BSI-Triforce-support-USA-UD Objet : FW: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf is, Please see attachment Doc10-09-2019 for joists marked that are upside down. Please review and advise of repair. If you need further info please let me know. Thanks Matt From: Brett Sallee [mailto:bsalleerdleaderhome.com] Sent: Monday.October 14, 2019 1:59 PM To: Loiselle. Matt Subject: FNv: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Hello Mr Ron Bercume asked me to send this info to you for his house in Northampton Ma. where the framer put tri-force joists in upside down. Please let me know if you need more info. THX Brett Sallee Owsi& salcs i-at.lrr Boil'« cn.t�; imm auuve. wee caicuiarion ror aerans. /7 R1 R1R 1 R 1 `a x '.!,1�1 '' : , N a: ZO RiE CIO c0 _. --@J o >. II i i' N o _ _ a. m o0 .D N W T _ — _ _ S C � X cr- / r fcv CV c) -- - - -10 X J 6-- .. M J Cont Strongba 1 I om .I �� m — � N �1 R1 -_ __ � �r - cu E + � BLK1 LLI v' — E i o�2 ply G3 _-- — �� Ci 4 ly 6 f H2— /7 x LK1 It ' 1 11 ---- — —ago — a J2 OJ 314 11.875" @a 16" RI RI Please review: oco I-_ ' Cont Strongback 1 ly 2 X 6 bottom M All dropped beam sizes have incre — U— — -- 4 nly B5 BLK1 C f� Ir � m x _ Cont Strongback 1 ply 2 X 6 bottom —J5 OJ314 11.875" @CL 16" MM R1 R1 Subject: F«•: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Hello Please do layout+quote for attached house plans. Job name Bercume/Maynard st Northampton Ma. 117/8"tri-force joists for 1st floor only with 1N-1's for any beams needed. No quote needed for 2nd floor. 2nd floor will be 2x12's THX Brett Sallee Outside Sales I Leader Home Centers c: 413.530.2655 1 p: 413.774.6311 1 f: 413.774.6317 Greenfield. MA Objet : RE: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Good morning Matt, Please find the additional calculations in question. Thanks for the help Matt. There's no current way to run the joists upside down in I-struct from what I can see, otherwise I'd try and tackle this. Thanks, Gabe LaBelle Engineered Inside Sales Submit plans & inquires to: plans_ co� astalfp.com t: 800-932-9663 1 p: 603-706-4295 www.coastalfp.com 660 River Rd, Bow,NH 03304 4 �*COASTAL FOREST PRODUCTS Our new postal address : PO Box 3788, Concord, N11 03302 From: Loiselle, Matt<Matt.Loi sellena.ca.ebarrette.com> Sent: Tuesday, October 15, 2019 8:34 AM To: Gabe LaBelle< labelle_,coastalfp.com> De : Loiselle, Matt Envoyk: 16 octobre 2019 15:50 A:Foucault,Jean-Sebastien;Gabe LaBelle Objet:RE: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Thanks JS. I will let the builder and dealer know. From: Foucault,Jean-Sebastien Sent:Wednesday,October 16,2019 1:50 PM To: Gabe LaBelle;Loiselle,Matt Subject: RE: 19012 bercume house MAYNARD CUSTOM 9 MAY 2018.pdf Good afternoon, All joist sent are still good to go even if installed upside down. Should have a letter done by the end of the day for it. Best regards, Jean-Sebastien Foucault 0:800.263.7265 C:819.386.2061 F:819.374.4527 www.openioisttriforce.com "\q k TRIFOR.V MWWMM CE- De: Gabe LaBelle [mailto:glabelle_ coas p.com] Envoy6: 15 octobre 2019 11:19 A : Loiselle,Matt Cc: BSI-Triforce-support-USA-UD BUILT BY "\qjTRIFORCE Barre A 4F4 Trois-Rivi6res, September 18th 2019 Subject: Upside down joist for Bercume Residence,79 Maynard, Northampton, MA To whom it may concern, This letter is to inform you that TRI FORCE° floorjoist J1, 117/8" depth, OJ314, of 7'-5 1/4" long and installed at 16"c/c, floor joist J2, 117/8" depth, 0J314, of 9'-11 11/16" long and installed at 16"c/c, floorjoist J3, 117/8" depth, 0J314, of 11 -4 1/2" long and installed at 16"c/c, floorjoist J4, 117/8" depth, 01314, of 13'- 119/32" long and installed at 16"c/c and floorjoist J5, y 117/8" depth, 0J314, of 15'-4 1/2„ long and installed at 16 c/c can support a live load of 40 psf and a dead load of 10 psf even if they're installed upside down. Best regards, Jean-Sebastien Foucault 555, rang St-Malo Trois-Rivi6res, QC G8V OA8 CANADA Encl.: J1, J2, J3, J4 and J5 Analyzerjoist reports Barrette Structural Distribution Inc. 555, rang St-Malo, Trois-Rivi6res QC G8V OA8 Toll Free : 1 800 263-7265 www.openjoisttriforce,com Manufacturer or Distributor References Coastal Forest Products Drawing by: Gabe LaBelle 451 South River Rd Job number: \'NITRIFC)RCE Id: J1 03110 Project: 19-1057 Leader Customer: Building Address: 79 Maynard stNorth Hampton MA Manufactured length:8' Perimeter Materials Characteristics(Use,Depth.Top-Bottom,Plies,Spacing) Trim Left:0",Right:6.237' Left:None,Right:None Triforce OJ314(Floor-Joist,11 7/8",3 X 2,1 ply,16"o.c.) 117/8" L R Overall length-7'5 3/4" Top Roll(m)=o° Pitch(0)=o° Lbl#Area Type X1 X2 Y Z O L Lp Loads AlArea o" 7'5 3/4" 7'5 3/4" 8" (psf): L=40, D=10 Aa o" 7'5 314" 7'S 314" $" (psf):L=40, D=10 STRENGTH LOAD CASES LC1 : D LC2: D+L LEGEND: L: Live. D: Dead. UNFACTORED REACTIONS Bearing L R Min Max Min Max Partial 0 1 0 1 Is Uplift Dead 51 51 49 49 Live 0 202 0 1 197 Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:1 of 2 BEARING ANALYSIS Real Bearing Min Calc. Bearing Normal Uplift Label Center,Width, Perp.Width CB Center, Width CB R Ra Co R/ Critical R Co Critical (in) (in) (lb) (lb) (RaCo) LC-Part (lb) LC-Part L 2.188", 4.375", 3.5" 1.00 NA, NA NA 253 2271 NA 0.11 2-1 NA NA NA R 88.888", 1.75", 3.5" 1.00 NA, NA NA 246 1 935 1.00 0.26 2-1 NA NA NA R ANALYSIS Axis Max At V VaCD Co V/Va Critical in Ib (lb) I I LC-Part Z 14.188" 174 1100 1 1.00 1 0.16 2-1 BENDING ANALYSIS T� -�® ffZ45.188" AtE435 M CL MaCD CD M/Me Critical (in) Ib.ft Ib.ft) LC- Part 1.00 3035 1.00 0.14 2-1 DON Axis Critical I Calculated Criteria Calc. LOAD CASE Part A Camber A, - Camb (in) I (in) (i n) (in) Crt. Z 0 L ISpan L-R LCL1 : L 1 0.018" NA I NA I U4771 0.181" U480 0.10 Z A r ISpan L-R LCT2 : D+L 1 0.023" 1 NA I NA I U3817 0.241" U360 0.09 P���j STRESS CAPACITIES AND MODIFICATION FACTORS K=37030001b E'=1400000psi EI'=285E61b*in2Elcomp'=357E61b*inz CMb=1.00 CMv=1.00 CMcp=1.00 CMe=1.00 Crb=1 Kcr=1.50 NOTESENGINEERING Lateral Supports: For Joists, lateral support at a minimum of 16"o.c is always required on top chord, as well as on bottom if there are more than two bearings or a cantilever condition. Subfloor: Plywood 24oc 5+Ply(23/32") Glued and Nailed/Screwed and Supported at edges Quotation -The Span of calculation is center to center of the real bearings. -The position of Shear and Bending in the analysis is from the left end of the Span of calculation. NOTESGENERAL Analysis and design are in accordance with ICC2015 and NDS2015. Refer to manufacturer technical documentation for installation, specifications and restrictions of use. Building designer is responsible for verifying building system as a whole. This analysis is for individual building component only and is based on information provided by the client. The component designer is responsible only for the structural adequacy of the component based on design criteria and loadings shown here and disclaims any responsibility for damages as a result of faulty or incorrect information provided by the client. Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:2 of 2 Manufacturer or Distributor References Coastal Forest Products Drawing by: Gabe LaBelle 451 South River Rd Job number: kTRIFORCE Id: J2 03110 Project: 19-1057 Leader Customer: Building Address: 79 Maynard stNorth Hampton MA Manufactured length:10' Perimeter Materials Characteristics(Use..Depth,Top-Bottom,Plies Spacing) Trim Left:0",Right:0.31" Left:None,Right:None Triforce OJ314(Floor-Joist,11 7/8",3 X 2,1 ply,16"o.c.) 117/8" L R Overall length=9'11 11/16" 10 Top Roll(m)=o° Pitch(0)=o° Lbl Nb @ c/c Type Xl X2 Y Z 0 L Lp Loads Al 1 Area I 0" 9'11 11/16" 9'11 11/16" 8" (psf):L=40, D=10 A2 1 Area o" 9'11 11/16" 9'11 11116' 8" (psf):L=40, D=10 STRENGTH LOAD CASES LC1 : D LC2: D+L LEGEND: L: Live. D: Dead. UNFACTORED REACTIONS Bearing L R Min Max Min Max Partial 0 1 0 1 Is Uplift Dead 66 66 66 66 Live 0 266 0 266 Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:1 of 2 Real Bearing Min Calc. Bearing Normal Uplift LabelCenter,Width, Perp.Width CB Center, Width Ce R Ra CD R/ Critical R CD Critical (in) (in) (lb) (lb) (RaCD) LC-Part (lb) LC-Part L 7 1.75", 3.5", 3.5" 1.00 NA, NA NA 332 2271 NA 0.15 2-1 NA NA NA R 117.94", 3.5", 3.5" 1.00 NA, NA NA 332 1250 1.00 0.27 2 1 NA NA NA SHEAR ANALYSIS Axis Max At V VaCD CD V/Va Critical in Ib (lb) LC- Part Z 1 13.75" 256 1118 1.00 0.23 2-1 BENDING ANALYSIS Axis At M CL MaCD Co M/Ma Critical (in) Ib.ft Ib.ft LC-Part Z 59.75" 781 1.00 3035 1.00 0.26 2-1 • Axis Critical Calculated Criteria Calc. LOAD CASE Part A Camber A - Camb A -- (in) (in) (in) (in) Crt. Z I A L ISparn L-R LCL1 : L 1 0.046" 1 NA NA L/2541 0.242" U480 0.19 Z A T Span L-R LCT2 : D+L 1 0.057" L NA NA L/2033 0.323" 0360 0.18 STRESS CAPACITIES AND MODIFICATION FACTORS K=37030001b E'=1400000psi EI'=285E61b*in2 Elcomp'=357E61b*in2 CMb=1.00 CMv=1.00 CMcp=1.00 CMe=1.00 Crb=1 Kcr=1.50 NOTES Lateral Supports: For Joists, lateral support at a minimum of 16"o.c is always required on top chord, as well as on bottom if there are more than two bearings or a cantilever condition. Subfloor: Plywood 24oc 5+Ply(23/32")Glued and Nailed/Screwed and Supported at edges Quotation -The Span of calculation is center to center of the real bearings. -The position of Shear and Bending in the analysis is from the left end of the Span of calculation. NOTESGENERAL Analysis and design are in accordance with ICC2015 and NDS2015. Refer to manufacturer technical documentation for installation, specifications and restrictions of use. Building designer is responsible for verifying building system as a whole. This analysis is for individual building component only and is based on information provided by the client. The component designer is responsible only for the structural adequacy of the component based on design criteria and loadings shown here and disclaims any responsibility for damages as a result of faulty or incorrect information provided by the client. Dale:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:2 of 2 Manufacturer or Distributor References Coastal Forest Products Drawing by: Gabe LaBelle 451 South River Rd Job number: \N91TRIFORCE Id: J3 03110 Project: 19-1057 Leader Customer: Building Address: 79 Maynard stNorth Hampton MA Manufactured length.12' Perimeter Materials Characteristics(Use,Depth,Top-Bottom,Plies,Spacing) Trim Left:0",Right:7.513" Left:None,Right:None Triforce OJ314(Floor-Joist,11 7/8",3 X 2,1 ply,16"o.c.) L R Overall length = 11'4 1/2" Top Roll(m)=o° Pitch(0)=o° r1Lbl Nb @ c/c Type X1 X2 Y Z 0 L Lp Loads Al Area 0" 11'41/2° 11'41/2° 8" (psf):L=40, D=10 Az 1 Area 0° 11�41/Z° 11�41/2" $° (pSf):L=40,D=10 LOADSTRENGTH CASES LC1 : D LC2: D+L LEGEND: L: Live. D: Dead. UNFACTORED REACTIONS Bearing L R Min Max Min Max Partial 0 1 0 1 Is Uplift Dead 1 76 76 76 76 Live 0 304 0 1 302 Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:1 of 2 ®� Real Bearing Min Calc. Bearing Normal Uplift Label Center, Width, Perp.Width Ca Center,Width 1 Ce R Ra CD R/ Critical R Co Critical (in) (in) (Ib) (lb) (RaCD) LC-Part (lb) LC-Part L 2.188", 4.375", 3.5" 1.00 NA, NA NA 380 2271 NA 0.17 2-1 NA NA NA R 134.737", 3.5", 3.5" 1.00 NA, NA NA 378 1250 1.00 0.30 2-1 1 NA NA NA SHEAR ANALYSIS i Axis Max At V VaCD Co V/Va Critical in Ib (lb) LC-Part Z 14.188" 302 1100 1.00 0.27 2-1 BENDING ANALYSIS Axis At M CL MaCD Co M/Ma Critical in) (Ib.ft) (lb.ft LC-Part Z 68.188" 1017 1.00 3035 1.00 0.34 2-1 DEFLECTION Axis Critical Calculated Criteria C81C. LOAD CASE Part Camber - Camb (in) (in) (in) (in) Crt. Z A L ISpan L-R LCL1 : L 1 0.071" NA I A 01865 0.276" 0480 0.26 Z A T I Span L-R LCT2: D+L 1 0.089" NA NA 01492 0.368" U360 0.24 StRESS CAPACITIES AND MODIFICATION FACTORS K=37030001b E'=1400000psi EI'=285E61b"in2 Elcomp'=357E61b'in2 CMb=1.00 CMv=1.00 CMcp=1.00 CMe=1.00 Crb=1 Kcr=1.50 NOTES Lateral Supports : For Joists, lateral support at a minimum of 16"o.c is always required on top chord, as well as on bottom if there are more than two bearings or a cantilever condition. Subfloor : Plywood 24oc 5+Ply(23/32")Glued and Nailed/Screwed and Supported at edges Quotation -The Span of calculation is center to center of the real bearings. -The position of Shear and Bending in the analysis is from the left end of the Span of calculation. NOTESGENERAL Analysis and design are in accordance with ICC2015 and NDS2015. Refer to manufacturer technical documentation for installation, specifications and restrictions of use. Building designer is responsible for verifying building system as a whole. This analysis is for individual building component only and is based on information provided by the client. The component designer is responsible only for the structural adequacy of the component based on design criteria and loadings shown here and disclaims any responsibility for damages as a result of faulty or incorrect information provided by the client. Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:2 of 2 Manufacturer or Distributor References Coastal Forest Products Drawing by: Gabe LaBelle 451 South River Rd Job number: N1*qA,,,'i TRIFORCE Id: J4 03110 Project: 19-1057 Leader Customer: Building Address: 79 Maynard stNorth Hampton MA Manufactured length:14' Perimeter Materials Characteristics(Use.Depth,Top-Bottom,Plies,Spacing) Trim Left:0",Right:10,396" Left:None,Right:None Triforce OJ314(Floor-Joist,11 7/8",3 X 2,1 ply,16"o.c.) A' Al L R Overall length = 13' 1 19/32" 10 Top Roll(m)=o° Pitch(0)=o° Lbl Nb @ c/c Type X1 X2 Y Z O L Lp Loads Al 1 Area o" 13'1 5/8"J 13"1 518" 8" (psf):L=4o,D=10 A2 1 Area o" 13'15/87' 13"15/8 of 8" (psf):L=4o,D=10 STRENGTH LOAD CASES LCI : D LC2: D+L LEGEND: L: Live. D: Dead. UNFACTORED REACTIONS Bearing L R Min Max Min Max Partial 0 1 0 1 Is Uplift Dead 87 87 88 88 Live 0 348 0 352 Page:1 of 2 Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA NG ANALYSIS 5"M= Real Bearing Min Calc. Bearing Normal Uplift LabelCenter,Width, Perp.Width CB Center, Width Ce R Ra CD R/ Critical R CD Critical (in) (in) (Ib) (Ib) (RaCD) LC-Part (lb) LC-Part L 7 0.875", 1.75", 3.5" 1.00 NA, NA NA 435 1859 NA 0.23 2-1 NA NA NA R 155.854", 3.5", 3.5" 1.00 NA, NA NA 440 1250 1.00 0.35 2-1 NA NA NA SHEi�lk ANALYSIS Axis Max At V VaCD Co V/Va Critical in (lb) (lb) I LC- Part Z 13.875" 358 1113 1.00 0.32 2-1 Axis At M CL MaCD CD M/Ma Critical (in) Ib.ft) (Ib.ft) LC- Part Z 77.875" 1390 1.00 3035 1.00 0.46 2-1 DEPLECTION Axis Critical Calculated Criteria I Calc. LOAD CASE Part A Camber A -Camb A -- (in) (in) (in) (in) Crt. Z A L Span L-R LCL1 : L 1 0.122" NA NA L/1268 0.323" L/480 1 0.36 Z IAT Span L-R LCT2: D+L 1 0.153" NA NA L/1014 0.43" L/360 0.35 STRESS CAPACITIES • MODIFICATIOORS K=37030001b E'=1400000psi EI'=285E61b"in2 Elcomp'=357E61b"inz CMb=1.00 CMv=1.00 CMcp=1.00 CMe=1.00 Crb=1 Kcr=1.50— ENGINEERING NOTES Lateral Supports: For Joists, lateral support at a minimum of 16"o.c is always required on top chord, as well as on bottom if there are more than two bearings or a cantilever condition. Subfloor: Plywood 24oc 5+Ply(23/32")Glued and Nailed/Screwed and Supported at edges Quotation -The Span of calculation is center to center of the real bearings. -The position of Shear and Bending in the analysis is from the left end of the Span of calculation. GENERAL • Analysis and design are in accordance with ICC2015 and NDS2015. Refer to manufacturer technical documentation for installation, specifications and restrictions of use. Building designer is responsible for verifying building system as a whole. This analysis is for individual building component only and is based on information provided by the client. The component designer is responsible only for the structural adequacy of the component based on design criteria and loadings shown here and disclaims any responsibility for damages as a result of faulty or incorrect information provided by the client. Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:2 of 2 Manufacturer or Distributor References Coastal Forest Products Drawing by: Gabe LaBelle 451 South River Rd Job number: :\19k TRIFORCE Id: J5 03110 Project: 19-1057 Leader Customer: Building Address: 79 Maynard stNorth Hampton MA Manufactured length:16' Perimeter Materials Characteristics(Use,Depth,Top-Bottom,Plies Spacing) Trim Left:0",Right:7.509" Left:None,Right:None Trlforce OJ314(Floor-Joist,11 718",3 X 2,1 ply,16"o.c.) Al 117/8" L R ♦ Overall length = 15'4 12" 10 Top Roll(m)=o° Pitch(0)=o° Lbl Nb @ c/c Type X1 X2 Y Z 0 L Lp Loads Al 1 Area o" 15'41/2" 15'4 1/210 8" (psf):L=40,D=10 A2 1 Area o" 15'4 1/2" 15'4 1/211 8" (psf):L=40,D=10 STRENGTH LOAD CASES LC1 : D LC2: D+L LEGEND: L: Live. D: Dead. UNFACTORED REACTIONS Bearing L R Min Max Min Max Partial 0 1 0 1 Is Uplift Dead 103 103 102 102 Live 0 411 0 409 Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:1 of 2 N:j NG ANALYSIS Real Bearing Min Calc. Bearing Normal Uplift Label Center, Width, Perp.Width CB Center,Width Cs R Ra Co R! Critical R Co Critical (in) (in) (lb) (lb) (RaCo) LC-Part (Ib) LC-Part L 2.188", 4.375", 3.5" 1.00 NA, NA NA 514 2271 NA 0.23 2-1 NA NA NA R 182.741", 3.5", 3.5" 1.00 NA, NA NA 511 1250 1.00 0.41 2-1 NA NA NA SHEARA NALYSIS Max At V VaCo Co V/Va Critical Axis in (Ib) (lb) I LC-Part Z 14.188" 435 1100 1.00 0.40 2-1 BENDING ANAL Axis At M C� MaCo Co M/Ma Critical in (lb.ft) Ib.ftLC-Part Z 92.188" 1887 1.00 3035 1.00 0.62 2-1 DEPLECTIO Axis Critical Calculated Criteria Calc. LOAD CASE Part 'A Camber A -Camb A --- (in) (in) (in) (in) Crt. Z A Span L-R LCL1 : L 1 0.211" NA NA U855 0.376" U480 0.56 Z I A r ISpan L-R LCT2: D+L 1 0.264" NA NA 0684 0.502" U360 0.53 S*, RESS CAPACITIES AND MODIFICATION FACTORS K=37030001b E'=1400000psi EI'=285E61b*in2 Elcomp'=357E61b*in2 CMb=1.00 CMv=1.00 CMcp=1.00 CMe=1.00 Crb=1 Kcr=1.50 NOTES Lateral Supports: For Joists, lateral support at a minimum of 16"o.c is always required on top chord, as well as on bottom if there are more than two bearings or a cantilever condition. Subfloor : Plywood 24oc 5+Ply(23/32")Glued and Nailed/Screwed and Supported at edges Quotation -The Span of calculation is center to center of the real bearings. -The position of Shear and Bending in the analysis is from the left end of the Span of calculation. NOTESGENERAL Analysis and design are in accordance with ICC2015 and NDS2015. Refer to manufacturer technical documentation for installation, specifications and restrictions of use. Building designer is responsible for verifying building system as a whole. This analysis is for individual building component only and is based on information provided by the client. The component designer is responsible only for the structural adequacy of the component based on design criteria and loadings shown here and disclaims any responsibility for damages as a result of faulty or incorrect information provided by the client. Date:2019-10-15 STRUCTURAL ANALYZER Version:18.80.229.0 IMPERIAL USA Page:2 of 2 CHARLES D. BAKER GOVERNOR EDWARD A. PALLESCHI UNDERSECRETARY OF CONSUMER Commonwealth of Massachusetts AFFAIRS AND BU KARYN E. POLITO BUSINESS LIEUTENANT GOVERNOR Division of Professional Licensure Board of State Examiners of Plumbers and Gas Fitters DIANE OSYMONDS roN MIKE KENNEALY COMMISSER,DIVISION OF SECRETARY OF HOUSING AND 1000 Washington Street, Suite 710 PROFESSIONAL LICENSURE ECONOMIC DEVELOPMENT Boston, Massachusetts 02118 Advisory Regarding Elevator Sumps Adopted December 4, 2019 The following advisory is issued by the Board of State Examiners of Plumbers and Gas Fitters (`Board") with regards to recent changes to 524 CMR (the"Elevator Code") which may implicate provisions of the Uniform State Plumbing Code. Effective June 1, 2018 (with a concurrency period which ended on December 1, 2018),the Massachusetts Board of Elevator Regulations updated the provisions of the Elevator Code, which governs all elevator installations in Massachusetts. Among the new changes in the Elevator Code is a new requirement for a drain or sump pump. Specifically, ASME A17.1-2013 Section 2.2.2.5 (adopted by 524 CMR 35.00) states (with regards to the design and construction of elevator pits): "In elevators provided with Firefighters' Emergency Operation, a drain or sump pump shall be provided. The Sump pump/drain shall have the capacity to remove a minimum of 11.4 m3/h (3,000 gal/h)per elevator." There are many methods of installing such a pump/drain system. Where the discharge will be entering a building's sanitary waste disposal system, the pump/drain system requires special attention as a Plumbing System per M.G.L. c. 142, s. 1, 13, and 248 CMR 10.03. It should also be noted that the code does not prohibit utilizing the storm drainage system for this discharge if permitted by a local ordinance, by-law, rule, or regulation. To assist members of the elevator trade. Licensees, registered design professionals, and other interested parties in meeting this new requirement the Board would like to emphasize the following rules which govern plumbing systems of this type: "Discharge from gravity drains or pumps entering the sanitary or storm drainage system shall comply with the requirements of 248 CMR 10.00. Elevators utilizing hydraulic oil or other petroleum distillates which may be harmful to the sanitary of storm drainage system shall discharge through a properly sized oil/water separator installed in compliance with 248 CMR 10.091, Note: Licensees should note that installation of an oil minder pump would not accomplish the separation purposes of 248 CMR 10.09 in these types of installations and could also undermine the effectiveness of the pumping system in an emergency. Accordingly,the installation of an oil minder pump in lieu of a gas/oil separation system shall be construed as a violation of the code and is prohibited. ;,} TELEPHONE: (617) 701.8682 FAX: (617) 701-8652 TTY/TDD: (617) 701-8645 http://www.mass.gov/dpi :. b .yx n s f