22B-020 (5) 13 MEADOW AVE BP-2020-0692
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block:22B-020 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:woodstove BUILDING PERMIT.
Permit# BP-2020-0692
Project# JS-2020-001178
Est.Cost: $4000.00
Fee: $40.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: THE FIRE PLACE 180477
Lot Size(sa. ft.): 17816.04 Owner: HILIBANK TOM
Zoning: URB(100)/ Applicant: THE FIRE PLACE
AT. 13 MEADOW AVE
Applicant Address: Phone: Insurance:
P O BOX 606 _ (413) 397-3463 O W('
WHATELYMA01093 ISSUED ON.12/4/2019 0:00:00
TO PERFORM THE FOLLOWING WORK.VICENZA PELLET STOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 12/4/2019 0:00:00 $40.00
212 Main Street,Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
^
' ���_�
C ' �� � ton
_ _� _-__�
Massachusetts
DEPARTMENT OF BUILDING INSPECTIONS
212 Main Street * Municipal Building
Northampton, MA 01060
DEC
3 2019
3V�
LE OR WO At
..,,SLNGLE OR WO AMILY SOLID FUEL APPLIANCE PERMIT APPLICATION
'WQ NCOA ./PELLET,CORN, STRAW OR SIMILAR STOVES,OR FIREPLACES
Please fill inall appropriate information
1. Name ofApplicant :
*ooraao: ' =~ ^~ '— - / ,� -
2. Owner ofProperty
^� ����
Address.- / _Telephone:
3. Status ofApplicant Ownar /, Contmobor
^/
4. Type orBrand ofStove v�cr7n
5. UL Listing 0&/,1.,F'9
8. Estimated Cost 1/000
7. Email :
|fapplicant ianot the homnmowner:
Contractor name Email :
Construction Supervisor's License Number Expiration Date
Home Improvement Contractor Registration Number /^/« Expiration Date
All Applicants must complete a NMorAm/s Compensation Insurance Affidavit before we can issue a pmnn/t
8. Certification: | haurby certify that the information contained herein is true and accurate to the best ofmy
knowledge.
DATE.- / APPLICANT'S SIGNATURE— -` -
DATE.- HOMEOWNER'S SIGNATURE
APPROVED
DATE: BUILDING OFFICIALHL
4.
vicenza
4.2 APPLIANCE MINIMUM CLEARANCE TO COMBUSTIBLES
WARNING
DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 20"(508mm)CLEARANCE FROM CEILING TO APPLIANCE TOP.
4.2.2 STRAIGHT INSTALLATION
Through the wall installation Interior Vertical Vents
.* M
------- iti
a�a.. "'". "y'.
*SEE VENT MANUFACTURER'S INSTRUCTIONS
4.2.1 CORNER INSTALLATION
Through the wall installations Interior Vertical Vents
} 4. A♦!
1•
# ff
•il--
� 4a5 5
"p
*SEE VENT MANUFACTURER'S INSTRUCTIONS
4.3 FLOOR PROTECTION INSTALLATION REQUIREMENTS
EMBER PROTECTION
This appliance must be installed on a non-combustible protector that extends to the front,sides and back of the appliance as per the
minimum requirements below.
NOTE:Floor protection is required for spark and ash shielding.
a
L .a
�►I Imo-- ;.�
MINIMUM FLOOR PROTECTION
FRONT(I) SIDES()) VENT(L)
6"(152 mm) 6"(152 mm) SEE VENT MANUFACTURER'S
INSTRUCTIONS
H H
I �
4.4 OUTSIDE AIR
NOTE: We strongly suggest using outside air for all residential installations,especially for those that are energy efficient,
air-tight homes.
Outside air supply must not be over 8'(2.4 m)long.
Outside air vents must be made with 2"(50mm)diameter or larger metal or aluminum duct with a metal screen attached to the end
to keep out rodents(RV.C.or other materials may not be used).
The outside air inlet must not be above or within 12"(305mm)of the chimney termination,must have a rain cap or down-turned
elbow to prevent the water from entering and be located so that it will not become plugged by snow or other material.
4.5 DRAFT
Draft is the force which moves air from the appliance up through the chimney.The amount of draft in your chimney
depends on the length of the chimney, local geography, nearby obstructions and other forces.
Inadequate draft may cause back-puffing into the room and may cause plugging of the chimney.Too much draft may
cause an excessive temperature in the appliance, glowing red appliance parts or an uncontrollable burn which can all
lead to a chimney fire or a permanent damage to the appliance.
4.6 FIRE EXTINGUISHERS/SMOKE DETECTORS&CARBON MONOXIDE DETECTORS
This appliance is low carbon monoxide (CO) emission. Use of the appliance in a manner inconsistent with the operating
instructions in this manual can increase the smoke and the carbon monoxide (CO) emissions considerably. We recommend
having monitors for areas that are expected to generate carbon monoxide(CO)(e.g.pellet fuel bulk storage areas).
All homes with a solid fuel burning appliance should have at least one fire extinguisher in a central location,
known to all, at least one smoke detector and carbon monoxide (CO)detector in the room containing the
appliance. If the smoke detector sounds an alarm, correct the cause but do not de-activate or relocate the
smoke detector. If the carbon monoxide detector sounds an alarm, immediately vent the area, evacuate and
call your local fire department.
91.1A
H,
vicenza
5.5 VENT TERMINAL CLEARANCES
i�
B
R
6
Y
4
f {(
4 I i
B � _
f � Li11R[
i j p
NOTE: Illustration dimensions are to the
center of the exhaust exit point of the vent
CLEARANCES
inch m
A 12" 0.30 Clearance above grade,veranda porch,deck or balcony.(Including vegetation and mulch)
91, 0.23 Clearance beside or below any windows or doors that open.
B
12"* 0.30 Clearance above any window or door that opens.
C 18" 0.45 Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2'
(0.6m)from the center line of the terminal.
D 0" 0 Clearance to an outside corner wall.
E 3" 0.07 Clearance to an inside combustible corner wall or protruding combustible obstructions(vent chase,
etc.)
F 9" 0.23 Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other k
appliance.
G 3' 0.91 Clearance to a mechanical air supply inlet. .�
PPY� ,i
H 7'** 2.13 Clearance to a mechanical air supply inlet.
w
1 12"** 0.30 Clearance under a veranda,porch,deck or balcony.
J 24" 0.60 Clearance above the roof.
K 2' 0.60 Clearance from an adjacent wall including neighbouring buildings.
3' (0.9m)within a
L height of 15'(4.5m) Clearance to each side of center line extended above natural gas or propane meter/regulator
above the meter/ assembly or mechanical vent.
regulator assembly
* Recommended to prevent condensation on windows and thermal breakage
** This is a recommended distance.For additional requirements check local codes.
Will 00 i 0