Loading...
18C-136 (10) 68 BLACKBERRY LN BP-2020-0607 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 18C- 136 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0607 Project# JS-2020-001027 Est.Cost: $42000.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sg.ft.): 10846.44 Owner: LIVINGSTON HEATHER Zoning: URB(100)/ Applicant: VALLEY SOLAR LLC AT. 68 BLACKBERRY LN Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON:11/13/2019 0:00:00 TO PERFORM THE FOLLOWING WORK-21 PANEL ROOF MOUNT SOLAR 7.35 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/13/2019 0:00:00 $75.00 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner #/, Department use only Ja1-,ir City of Northampton of se mit: ,OX Building Department ('�{�� t�ar�,�uUDri eway Permit 212 Main Stre t �J._. 1 ewer/ eptic vailability S Room 100 Water ell A ailability Northampton, MA 0106 n l - fwd Set of St uctural Plans }" .�r �L phone 413-587-1240 Fax 4 3-5 7-1272 PIot/Site tans E$pbbfy APPLICATION TO CONSTRUCT,ALTER, REP R, I 1 )-VTE �nP LISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Map Lot I ✓� Unit 68 Blackberry Ln Northampton, MA 01060 Zone Overlay District Elm St.District CB District SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Heather Livingston 68 Blackberry Ln, Northampton, MA 01060 Name(Print) Current Mailing Address: 316-670-0269 Telephone Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: 413-584-8844 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only com leted by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) �'S 5. Fire Protection 6. Total= (1 +2 + 3+4 + 5) Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date Ihasbrouck @ northamptonma.gov info@val leysolar.solar EMAIL ADDRESS (REQUIRED; CONTRACTOR) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ID Roofing Q Or Doors 71 Accessory Bldg. ❑ Demolition ❑ New Signs [O] Decks [M Siding [0) Other[X solar Brief Description of Proposed Work: Installation of a 21 Panel solar roof mount array. System size 7.35 kW DC. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet sa. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Heather Livingston as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all matters relative to work authorized by this building permit application. J'Y[,CL��i.�t. c�Ll/LIL2+d�/SIL 11/04/2019 Signature of Owner U Date Valley Solar LLC as GwFwc/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. steven a silverman Print Name ,�,v-e n, 0'. ,�i,�v e,,rn Q n, 11/04/2019 signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Steven Silverman License Number CS-077279 Address Expiration Date 6/21/2020 Signature Telephone Av,-m a- '�''��'"'" 413-584-8844 9. Reqistered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/20 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ s SYSTEM BRIEF stallation of a 21 panel,6.09 AC Size(kW),7.35 fifi In � a DC Size(kW),roof mount PV solar system.The SnapNRack Ultra Rail racking system will use S5-5 clamps to attach to this standing seam roof. s ° PLAN LEGEND 3 a�, s - Roof Array 21x LG350NIC-VS solar PV modules ST UQ 21x EnphaselQ7PLUS-72-2-US c $ v z ,. 9 m micro-inverters m o SnapNRack Ultra Rail mounting system c Internal Wall of House m E 3 Enphase Combiner Box(N) c b AC Disconnect(N) Main Electrical Panel(E) Wall of House W Utility SMART Generation Meter(N) � AC Disconnect(N) C Utility Meter(E) 55 m B .. UTILITY INFO w �� <"' ,� • Utility Company National Grid d Utility Customer of Record Heather Livingston a }"# Utility Acct#50732-31012 LU Y� + Meter Number 87807584 F— �a - Ado-ea<68 Blackberry Lane,Northampton,MA 01060 L&It 0 �� -- '1 � • � meg$ S a flit > e. ` A C� Z. 0 a Bk:11470 Pg:214 D FI�iMo SLACLANE RRY � o � �� 99 NE ! � BLACKBERRY er 1 t<lavv 7+.auY .a¢ 5 m i Hewryaa: LANE 81 013 M.38 PM J d O SLAC*MIWY t A E LANE �TM MA99ACHU9ETT9 FNCIFf TAN 4FFE("IED PREMISES; NumP•n6.olalaa aoo n3om ate= . _68M NPOO MAe111t16U Dat*. OVM201303:35 PM UiI,1030436 M366 ex/0001BBA FH'.51,660ADC...:6310.00000 N 68 BLACKBERRY LANE KNOW ALL PERSONS BY THESE PRESENTS,THAT o .0 a BERRY NORTHAMPTON We,ROBERT A.CALLANDER individually and as TRUSTEE of the Robert A. w B � vt h w NE 7J rc BLACKBERRY i;:,,ner LIVINGSTON PATRICK& Callander Funding Trust and JEANNETTE W.CALLANDER,TRUSTEE of the BLACKBERRY LANE J LAW HEATHER Robert A. Callander Funding Trust, married to one another, of 4 Raymond P O.vner..dd`a,s s LAvenue,Easthampton,Massachusetts 68 BLACKBERRY LN o NC)RTt*AhtPTON MA010e0 for consideration paid, and in full consideration of Three Hundred and Forty to s Thousand($340,000.00)Dollars Z culldnq V2iue $237.100 � `s # Land Valu* 8120.200 grant to f 68 F— IT� P 11)e S0 Blackberry Lane,Northampton,Massachusetts,Husband and Wife as Tenants by SLAC114MM Y BLACKI.ERW Total"ue: S357,300 a n g LANE LANE the Entirety Assessment Cala from FV 2DI4 with WARRANTY COVENANTS Lot Size 0.25ncre5 The land situated at 68 Blackberry un Lane, Northampton, Hampshire County, Lact Sale Pnce $340.000 o E l r� Massachusetts,and being more particularly bounded and described on Exhibit"A" Last Sale Date 20130920 a 2 ti.e Cede 101 attached hereto and made a part hereof. mom so Z Z v 3 Y Keine the same nremises conveved to Robert A. Callander and Jeannette W. S o> LATHE U J m Q a� LACM:E:ERRY a _-of` m LANE 'm b > GE THIS ELECTRICAL DRAWING IS A PROPOSED DESIGN.t HE ELECTRICIAN IS Al LIBERTY TO ADJUST DURING I HE BUILD AND AMEND ME 11,5 W R L B1 REFLECTED IN THE AS-BUIIT DIAGRAM. 5 System Comoonents:C Inverter Trio Settings: Labelina Schedule h 1) Snap8LRack Ultra Rail racking BOM Inverter TRIP settin s are set in the inverter per the Iso NE SRD and ESB 756 section 7.6.11. 1)WARNING!PHOTOVOLTAIC POWER SOURCE 2) 21x(LG350N1C-V5)PV modules i DEVICE DEFAULT PICKUP I DEFAULTCLEARING I Pickups and 2)SOLAR PV AC COMBINER BOX y) 3 21 x IQ7PLUS-72-2-US Enphase microinverters sernNG TIME(seconds) CMaring Tlmss b a ) ( ) p 3 PV SYSTEM AC DISCONNECT Rated AC Output Current: (simplified defau#a I Adhere to Raqulrod ) p 4 2x(Q SEAL-10)Sealing Cap For Q Cable from 7.6.11) Defaults(Yes/No): 25.41AAC Nominal Operating Voltage:240V AC 3 0 2x(Q-TERM-10)Terminal Cap For Q Cable Under Frequency 56.5 Hz 0.16 Yes 4)RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 4) 1x(RSTC 0799-5B)Blk Soladeck (e1u) (reflective) a 5) 1x(X-IQ-AMI-240-3)Enphase Combiner Box Under Frequency se.s Hz 300 yea 5)WARNING!ELECTRICAL SHOCK HAZARD TERMINALS ON = 3 2x(BR220)20A 2P PLUG-IN 120/240V (s1u) BOTH LINE AND LOAD SIDES MAYBE ENERGIZED IN THE ° Over Frequency(61 O) 61.2 Hz 500 Vas t 1x(CT-200-SPLIT)set of 2 consumption CTs C Over Frequency(810) 62.0 Hz 0.16 vas OPEN POSITION m 1x(DLA LA-302R)1 P3W 250V Lightning Arrestor x?o under vollega(27) sOx of Nominal 11 vas 6)UTILITY GENERATION METER a m E� 6) lx(DG222URB)EATON 60AAC Disco non-fused under voltage(z7) 56%of Nominal 2 Yea 7)WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES m tY 7) 1x(U5934)Milbank 60A 1 PH 3W meter socket Over Voltage(59) 110%of Nominal 2 Yes I UTILITY GRID AND PHOTOVOLTAIC SYSTEM = z n 8) Main Service Load Center 200A main CB Over Voltage(59) 120%of Nominal 0.16 Yea g)WARNING!INVERTER OUTPUT CONNECTION DO NOT 1x(BR230)30A 2P PLUG-IN 120/240V RELOCATE THIS OVERCURRENT DEVICE N 9) Utility Service Meter 120/240V 1 PH 3W 9)WARNING!UTILITY METER ENERGIZED BY 2 SOURCES Z o D) % 10)UTILITY SERVICE METER $ Fnw y LINE on the top and the N y rn AC Isolation Device between O LOAD on the bottom side MOD MOD MOD MOD 1 Company meter&DER AC Isolation Device AC Isolation Device of the MA SMART Meter 9 1s MICRO 2 INVERTERS IN BRANCH 5 1 20 CIRCUIT ervice Parcel J SMART Meter AC AC AC Combiner Box _ U $' DC DC DC DCAC 3 4 3 u sox n b 4 5 w 6 9 9 10 J MOD MOD MOD AC Disco w M ^ M o MICRO (4)#1013 zAPmaleBL� as To/ � INVERTERS (t)#toGroen IN 3!4•EMT lel=11ODI�TION n Uflllty n o IN BRANCH 10/3 rix t v43 RXoft1013 Rx V From m CIRCUIT nipple AC _ AC AC AC GEC o a DC DC DC DC a S (1)716 CU THHN (2)#12 CU THWN•2. v) g EGC O Cable _ a (Utility Info: � it 11�j Company National Grid Communications: Conductor/OCPD Calculations: i Utility Customer n' < - `Li Heather Livingston g Utility Acct#50732-31012 Wifi to Envoy or CAT5 TBD (NEC 210.19(A)(1)(a)).Inverter IQ7PLUS-72-2-US Max Meter NumLe-87807584 Output=1.21A x 21 =25.41A x 1.25=31.7625A Address 68 Blackberry Lane,Northampton,MAO 1060 OPennFUSION 1 52 S. Broad E n 9 1 h B e r l ri y Lansdale, PA 1944466 (215)361-8040 November 4, 2019 Valley Solar 340 Riverside Dr Northampton, MA 01 062 RE: Livingston Residence 68 Blackberry Lane, Northampton, MA 01060 Client Project#:68LIV1 PFE Project#: 194494 On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads.Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size: 7.35 kW/DC Panel Specs: (21) LG Solar- LG350NIC-A5 Inverter Specs: (21)Enphase - IQ7+ Racking System: Iron Ridge- Flush Mount The modules are to be located on the following roof plane: Number of Mounting Rafter Rafter Horizontal Collar Collar Tie Shingle Ceiling Plane Size Spacing Span Ties Spacing Sheathing Type Shingle Layers Profile Metal 1 2x6 16" 1 3ft. Oin. N/A 0" CDX 112" Standing 1 Flat Seam The roof design has been analyzed in accordance with the 201 S International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows: Ground Snow(Pg): 40 psf Wind Speed (V): 120 mph Mounting Plane 1 The calculations for these structural members are attached. It has been determined by this office that the rafters, as specified above, exceed the allowable span for the total design loading.Attached are repair details that, when installed,will render the roof design structurally adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with Seam Clamps at 48 on center maximum. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. I N Of J,}A Best Regards, Penn Fusion Engineering LLC o G w^.^.REN DOVEN'C f, LEO%E J -.-_0-53M to �J Andrew D.Leone, P.E. Principal .� /STE ��� SS�nhAl qty.? Penn FUSION 1 iC��1A 1 152 S. Broad 46 1JS V l�! Lansdale, PA 19446 E.n 1 n e e r I n Sil (267)640-2758 Client Name: Valley Solar PFE Project Number: 194494 Client Project Number: 68LIVI Project: Livingston Residence Address: 68 Blackberry Lane Northampton, MA 01 060 Description: Mounting Plane 1 Calculations By: ADL Date: November 4, 2019 Roof Construction 2x6 Rafters at 16"on center A= 8.25 inz lx= 20.8 in Sx= 7.56 in Wood Species= Doug-Fir Larch#2 Fb= 900 psi Fv= 180 psi E= 1600000 psi Roof Slope= 23 ° Rafter Span= 12.98 ft Ceiling Attached to Rafters?: No Desian Criteria Ground Snow(Pg): 40 psf Design Wind Speed: 120 mph Live Load: 20 psf Dead Load: 4.43 psf PV Modules: 3.26 psf Wind Calculations Directionality Factor(Kd): 0.85 Topographic Factor(KZt): 1 Velocity Pressure Exposure 0 7 Coefficient(KZ): Importance Factor(1): 1 Velocity Pressure (q,): 21.93 psf Tributary Square Footage on 10.83 ft Component: Component Roof Pressures: 14.76 / -60.52 psf Snow Load Calculations Exposure Factor(Ce): 1 Thermal Factor(Ct): 1 Importance Factor(1): 1 Flat Roof Snow Loads (Pf): 35 psf Roof Slope Factor(CS): 0.723076923077 Sloped Snow Loads (PS): 25.2 psf Unbalanced Snow Load: 40 psf Member Calculations Bending Md: 1339.4 ft*Ib fb: 2125.32 psi Load Duration Factor(Cd): 1.15 Stability Factor(CO: 1 Wet Service Factor(CM): 1 Temperature Factor(CT): 1 Size Factor(CO: 1.3 Flat Use Factor(Cf„): 1 Incising Factor(C): 1 Repetitive Member Factor(C,): 1.15 Fb: 900 psi Fib: 1547.33 psi 2125.32>1547.33 No Good in Bending Shear Vd: 412.7 Ib f,: 75.04 psi Load Duration Factor(Cd): 1.1 5 Wet Service Factor(CM): 1 Temperature Factor(CT): 1 Size Factor(CO: 1.3 Flat Use Factor(Cf„): 1 Incising Factor(Cl): 1 Fv: 180 psi Fav): 207 psi 75.04<=207 OK in Shear Deflection Live Load Deflection (AL): 1.02 in L/1 52 No Good in Live Load Deflection Total Load Deflection (AT): 1.22 in L/128 OK in Total Load Deflection Uplift Calculation Tributary Square Footage on 10.83 ft2 Component: Uplift Pressure: -60.52 psf Uplift per Lag: -655.63 lbs Lag Screw Diameter: 5/16 in Allowable Withdrawal per Inch: 490.99 lbs/in Minimal Screw Penetration: 1.34 in Install 5/16"diameter lag screws @ 48 on center with minimum penetration of 2" into rafter. Penn FUSION 152 S. Broad St.ansdale, PA 19446 V L E n y ! n` e c I n (267)640-2758 Client Name: Valley Solar PFE Project Number: 194494 Client Project Number: 68LIVI Project: Livingston Residence Address: 68 Blackberry Lane Northampton, MA 01060 Description: Mounting Plane 1 Calculations By: ADL Date: November 4, 2019 OCG� O��t a.,`�•l �'f -,'..�'' / ``—EXISTING RAFTER P:E„t SISTEREU RAFTER. SEE `-SCHEDULE SELCM FOR SIZE AND NAILING REQUIREMENTS New Sistered Rafter Size: 2x6x4' Doug-Fir Larch #2 or better* Nailing Requirements: (2) 1 Od Nails @ 12” on center with (3)additional l Od Nails at each end 1 Od = .12"shank diameter x 3"long minimum Note: Apply repair to each rafter under PV system *Suitable Alternate Species: -Spruce-Pine-Fir#2 or#1 -Southern-Yellow-Pine#2 or#1 x4 9Is s, 2 &. 1 A t , LG35ON1 C-V5 35OW The LG NeON©2 is LG's best selling solar module,and is one of the most powerful and versatile modules on the market today.Featuring LG's Cello Technology,the LG NeON®2 increases power output.New updates include an extended performance warranty from 86%to 90.08%to give customers higher performance and reliability. DVE C VI. us C� �MawJ r• :l' re, Features Enhanced Performance Warranty Enhanced Product Warranty �j," LG NeONO 2 has an enhanced LG has extended the warranty of the performance warranty.After 25 NeON®2 to 25 years including labor, years,LG NeON8 2 is guaranteed at which is top level in the industry. least 90.08%of initial performance. Better Performance on a Sunny Day * Roof Aesthetics �QH2Q LG Ne0N6 2 now performs better on LG NeONO 2 has been designed with sunny days,thanks to its improved aesthetics in mind using thinner wires temperature coefficient. that appear all black at a distance.The LG NeONO 2 can increase the aesthetic value of your home with a more modern design. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics LG Electronics is a globat leader In electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked an a solar �� Solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials Industries.In 2010,LG Solar successfully released Its first MonoXe seines to the market,which is now available in 32 countries.The NeONO(previous MonoXe NeON),NeONe2,NeONe2 BiFacial won the"Intersolar AWARD"In 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. LG35ON1C-V5.lndd 1 6/27/19 102 PM LG NeON®2 LG350N1 C-V5 Preliminary General Data Electrical Properties(STC*) Cell Pmperdes(Material/Type) Monocrystalline/N-type Model LG3SON1C Vs .. erre.. erre ._ •-0101-_--.____...----0101.___.0101-•--- . - errs .._._......_.. suss Cell Maker LG Maximum P.—(Pmax) [W] 350 Cell Conflqurabm 60 Cells(6 x 10) MPP Voltage(Vmpp) ['J] 353 Number of Busbars 12EA MPP current(Impp) [A] 9.92 Modtde Dimensions L x W x H Ir: 1,686mm x 1,Ot6mm x40 mm 0 __-_,._ ....._errs. ....._......... ( ) pen Cin uit Voltage(Vac, 5%) [V] 41.3 Weight ' ' 171 kg Shortrcu Circuit Currant(1.,_5%) [A] 10.61 Giass(Material) Tempered Glass With AR Coating - Module Efficiency ] 20.4 .Baekshnet(Odor) D@gRe) ��• _. _.__ .IP 68 with Bypass Diodes , _ Power Tolerance [%] 0-+3 frame(Materni) ':^r Anodized Alumnnlm STC(Standard Test Condition).Irradance 1000 W/m',.11 temperature 25'C,AM 1 5,Mansura 7okxance.!3% luncdon Box Pmtectlon�- .._...... Cables(Lengtb) _ s ` _ 1,000mmx 2EA __ Operating Conditions Lornseutor(Type/Maker) wr { x; MC4/MC .Pamtm.,---,r.-we EeC ' 40-+90 -.:_._. ruse. k4axle—System Voh'agis I [V] 1000(IEC).-____-_.__.__ MaxLrrum Series fuse Rating (A] _ 20 Certifications and Warranty Mechanical Test t,oad•(fmm) [Palpsf]j 5,400/113 IEC61215-1/-1-1/2:2016,IEC61730-1/2:2016 errs. ..--- _._... _ ..-.0101-___0101 _MecFwllcalTess Laad•(Rear). [Pa/psf3:; 4,000tB4 Cerdfitatiotle Y: a d j ISO 9001,ISO 14001,ISO 50001 •Mechan-1 Test Loads 5,400 Pa/4,000 Pa based on IEC 61215-2:2016(Test Load-Design Load x Safety OHSAS 18001 ... Factor(1.5)) Salt Mist CmmsionTert _ r' _-_-_,-IEC 61701 2012 Seventy 6 Packaging Configuration Ammonia Corrosion Test - IEC 62716:2013 Number of Modules per Pallet [EA] 25 fire Rating Class C(UL 790) Number ofMo&Aes per 40R HQ Container [EA] 650 _Solar Module Pmdid Waztanty 2S Years 0101:_. _.._. _.__. Solar Module Output Wwvw Ly Linear Warranty' Packaging Bar Dimensions(L x W v H) [mm] 1,750 x 1,120 x 1,221 .Improvedlstyear98%,from224th year 0.33%/yaardmn,after 25thyear 90.08% ..Packaging Box:Gross NM9M_ [kg] # 464 Temperature Characteristics Dimensions(mm/inch) NMOT* IT] - 42 t 3 Pnax [%/°C] -0.36 V. [%PC] -0.27 - mra.aso.a 003 ete.ore.. [lint:wriladiI •NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m2,Ambient temperature 20'C, Wind speed l m/s,Spectrum AM 1.5 ore.a w.a is'r o-v„e�ro xei.. �r.exi Electrical Properties(NMOT) Wil Model 1.6350N1C-VS 0101__._..__ •_.:__ -Maximum Pistxer(Prnax) [WJ ...-.261 MPP Voltage(V11 _ [V] 33.0 i.._ MPPCurnent(Impli) :i (A] 7.91 .___..-.._ Open[haft Voltage(Voc)% M 38.80 _. -'- Sher[ClmdtCtamrt(hc)� IN Curves 110 -- tOWw 1 IUD e00W Q 8.0 60ON' C 8.0 u' 4.0 .-,..-_.-.._ 40M 1(IOW . e 0.0 0.0 10.0 20.0 30.0 40.0 Voltage M ® LG LG Electronics Inc. Solar Business Division Product specifications are subject to hangs w thou[notice. 2000 Millbrook Drive LG350N1 C-VS_AUS.pdf Lincolnshire,IL 60069 Life's Good www.ig-solarcam 0 2019 LG Electronics.All rights reser ad. r LG35ON1GV5.indd 2 6127!19 1'.02 PM i Data Sheet Enphase Microinverters Region. AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro" IQ 7 and ICS 7+ dramatically simplify the installation process while achieving the highest system efficiency. 1t'�tnV�� er Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple a Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. U� To learn more about Enphase offerings,visit enphase.com % ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commgnly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27V-37V 27V-45V Operating range 16V-48V 16 V-60 V Min/Max start voltage 22V/48V 22V/60V Max DC short circuit current(module lsc) 15A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 4 PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5,8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port Ill III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging 99 9 EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3'1% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range 40°C to+650C Relative humidity range 4%to 100°%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS 72-2-US) MC4(or Amphenoi H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class If double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at hitns Hen phase com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v E N P H A S E. ©2019 Enphase Energy_All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2019-3-26 SNAPNRACK UR-40 RACKING SYSTEMREVISION: SHOWN MOUNTED ON ULTRA FOOT WITH SNAPNRACK A 11/302017 NEW DETAIL MA UNIVERSAL END CLAMPS.FOR TILE MID CLAMP, TyP' ROOFING USE SNAPNRACK TILE "RAIL END OVERHANG" — REPLACEMENT,UNIVERSAL TILE HOOK,OR NOT TO EXCEED 34%OF — — FIAT TILE HOOK SYSTEMS. ACCEPTABLE RAIL SPAN — STANDARD LAG SCREW SPEC ASSUMES SNAPNRACK UNIVERSAL END CLAMP ASSEMBLY,TYP. %6"0 LAG SCREW WITH 2%"MIN. EMBEDMENT INTO STRUCTURAL MEMBER. TORQUE SPECIFICATIONS: / SNAPNRACK ROOF ATTACHMENT %6"0 NUTS&BOLTS,10-16 FT-LBS SNAPNRACK UR-40 RAIL,TYP. (MODULE HIDDEN FOR CLARITY) RAILS CAN BE MOUNTED ON EITHER SIDE OF ULTRA FOOT;UPSLOPE OR DOWNSLOPE. FOR UNEVEN ROOF SURFACES,UTILIZE DETAIL A THE SNAPNRACK LEVELER EXTENSION LEVELING SPACER.SEE DETAIL(S) \ "RAIL SPAN"IS DEFINED AS "UR40-DOI,""UR40-D08,""UR40-D09,"& DISTANCE BETWEEN 'UR40-D10,"FOR DETAILS AND ROOF ATTACHMENTS LIMITATIONS. A "STRUCTURAL MEMBER(S)" MAY REFER TO RAFTERS,PURLINS, BEAMS,OR OTHER STRUCTURAL, LOAD-CARRYING MEMBERS SNAPNRACK MID CLAMP,TYP; CLAMP ASSEMBLY SHALL BE SELECTED TO MATCH PV MODULE "MODULE OVERHANG" NOT TO EXCEED 25%OF MODULE LENGTH OR MODULE MANUFACTURERS `RECOMMENDATIONS SNAPNRACK ROOF ATTACHMENT LAG SCREWED INTO STRUCTURAL MEMBER. NO FLASHING SHOWN FOR CLARITY. �\\ �'�\)IIrIn Ir'�(!�� (/�IIr Sunrun South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: DESCRIPTION: REV G"n(r.�'lJIIC/N ra VUU F"ter soAaww 0arq[W11 r"o�mona crura"ur lJ DRAFTER: M.Affentranger UR40-D06 UR-40 TYPICAL LAYOUT , R°E" ­.E.1 s�"".m "a. DATE: 11/30/2017 APPROVED BY: G.MCPheeter5 SNAPNRACK UR-40 RAIL SHOWN SPLICED REVISION: TOGETHER WITH THE SNAPNRACK ULTRAA unrz017 NEW DETAIL MA RAIL SPLICE. 2"MAX �" '/"RAIL GAP — — 2"MIN FOR THERMAL EXPANSION — — TOROUE SPECIFICATIONS: AT SPLICES _ 5/s"O NUTS&BOLTS,10-16 FT-LBS — CENTER SPLICE BETWEEN THE TWO BONDING CLIPS AS SHOWN IN"SPLICE ALIGNMENT LIMITS"VIEW ons RAIL EDGE MUST NOT PASS—/ SPLICE ALIGNMENT LIMITS THE CLIP EDGE,AS SHOWN. $� TSNNPAPNRACK UR-40 RAIL, SNAPNRACK BONDING CLIP,TYPE 2 FOR BONDING ACROSS RAILS 8 %6"0-18 BOLT,S.S. SNAPNRACK ULTRA SPLICE ASSEMBLY, CENTER ON RAIL GAP t 1" SNAPNRACK ULTRA SNAPNRACK ULTRA SPLICE,THRU SPLICE,TAPPED _ Sunrun South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: DESCRIPTION: REV ~f 1j11U, ���(��� »" E.�" :M:.stl DRAFTER: M.Affentranger UR40-D05 UR-40 ULTRA SPLICE DETAILS A DATE: 11/7/2017 APPROVED BY: G.MCPheeter5 City of Northampton rt rir 0" . Massachusetts AV DEPARTMENT OF BUILDING INSPECTIONS .' 212 Main Street •Municipal Building Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 68 Blackberry Ln, Northampton, MA 01060 (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) 11/7/19 Signature of Permit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. The Commonwealth of Massachusetts Department of Industrial Accidenty Ogee of Investigations ;. 600 Washington Street µ Boston,MA 02111 �y www.mass.gov/dia Workers' Compensation insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name„;Usines,;/Organiz.itionrinlividtt:tll: Valley Solar LLC Address:340 Riverside Drive PO BOX 60627 City/State/Zip:Florence, MA 01062 Phone#: 413-584-8844 _ Are you an employer?Check the appropriate box: Type of project(required): 1.10 1 am a employer with 11 4. [] 1 am a general contractor and I employees(full and/or part-time)." have hired the sub-contractors 6. E]New construction 2.❑ 1 am a sole proprietor or partner- l isted on the attached sheet. 7. ❑ Remodeling ship and have no employees "These sub-contractors have g, E] Demolition working for me in any capacity, employees and have workers' q E]Building addition [No workers'comp.insurance comp.insurance,] required.] 5. We are a corporation and its 10.❑Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I LEJ Plumbing repairs or additions myself [No workers'comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152,§1(4),and we have no employees.[No workers' 13.®OtherS0lar camp.insurance required.) 'Any applicant that clwvks box#1 nuns also till out the station below showing their workers'compensation policy inliirmation. t I lomeowners who submit this allidavit indicating they are doing all work and then,hire outside contractors must submit a new all'idavit indicating such. tC ontrtctors that check this box must attached tui additional sleet showing the name of the sub-contractors and state whether or not those entities have employees if the sub-contructors have cmplovtrs,they must provide their workers'comp.polky number. t am an employer that is providing workers'compensation insnranc'e frrr my emplgyees. Be'loov is the polity an iuh site inforandion. Insurance Company Name:.-Liberty Mutual Policy ii or Self=ins.Li,.tt:WC531 S620647019 Expiration Date: 2/1/2020 _ Job site Address: 68 Blackberry Ln, _ city/state/zip: Northampton, MA 01060 Attach a copy of the workers'compensation policy declaration page(showing;the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify undo 1 aIns and pe hies of per a infornutd nr prmmided above is true runt c•nrrect. r Si nature: / Date: �� -��) Phone If: 413-584-8844 -— Oj)'iclu/ase onlgt Do not write in this area,to be completed h3 ity Or town Official City or Town: Permit/License# Issuing;Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing:Inspector 6.Other Contact Person: Phone 1/: