Loading...
43-112 137 PARK HILL RD BP-2020-0546 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:43 - 112 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0546 Proiect# JS-2020-000942 Est.Cost: $23270.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sq. 1): 62726.40 Owner: GEORGE COLLEEN E Zoning. Applicant. VALLEY SOLAR LLC AT. 137 PARK HILL RD Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON.10/29/2019 0:00:00 TO PERFORM THE FOLLOWING WORK.-ROOF MOUNTED SOLAR, 20 PANELS 7KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTvpe: Date Paid: Amount: Building 10/29/2019 0:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only `4i :mr City of Northampton Status of Permit: 4" Building Department Curb Cut/Driveway Permit C 212 Main Street Sewer/Septic Availability 4 Room 100 Water/Well Availability Ste" Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans O APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR D MOLISH A ONE OR TWC FAMILY DWELLING SECTION 1 -SITE INFORMATION q3 112- OCT 2 9 2019 1.1 Property Address: LThis section t2 he rnn plete J by office DEPT OF BUILDING,INSPECTIONS Map NORTHAmrTON&AO1060 Unit 137 Park Hill Rd., Northampton, MA 01060 Zone Overlay District Elm St. District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Colleen George 137 Park Hill Rd., Northampton, MA 01060 Name(Print) Current Mailing Address: � + n, 413-210-7503 1 �"] Telephone Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: 413-584-8844 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) Uo 5. Fire Protection 6. Total= (1 +2 + 3+4+5) Check Number Lit o(� This Section For Official Use Only Building Permit Number: Date Issued: Signature: IIJ, Building Commissioner/Inspector of Buildings Date Ihasbrouck @ north amptonma.gov info valleysolar.solar EMAIL ADDRESS (REQUIRED; CON ACTOR) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all awlicablel New House ❑ Addition ❑ Replacement Windows Alterations) Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [O] Decks [Q Siding[0] Other[X Solar Brief Description of Proposed Work: Installation of 20 Panel solar roof mount array. System size 7 kW DC. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1, Colleen George as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all matters relative to work authorized by this building permit application. LE;R 10/16/2019 Signature of Ow er Date Valley Solar LLC as Gwfw/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Steven Silverman Print Name ►t, 0_ � 10/25/2019 Signature of Owner/Agent Date SECTION 8 -CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder. License Number Steven Silverman CS-077279 Address Expiration Date 268 Fomer Road, Southampton, MA 01073 6/21/2020 Signature Telephone x) { 0— A,&,-tA rr n 413-584-8844 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/20 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street :X'•;`ij4 . Boston, MA 02111 www.massgov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Letibly Name(Rusir)css/Organiiuiott/l►ulividual): Valley Solar LLC Address:340 Riverside Drive PO BOX 60627 City/State/Gip:Florence, MA 01062 Phone#: 413-584-8844 Are you an employer?Check the appropriate box: Type of project(required): 1.10 1 am a employer with 11 4. ❑ 1 am a general contractor and I employees(full and/or part-time). have hired the sub-contractors �� ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers9 ❑Building addition [No workers'comp.insurance comp.insurance? required.] 5. We are a corporation and its 10.❑Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 1 L[J Plumbing repairs or additions myself. [No workers'comp. right of exemption per MGL 11_.❑ Roof repairs insurance required.]t c. 152,§1(4),and we have no employees.[No workers' I,.®OtherSOlar comp.insurance required.] *Any appficant that checks box A 1 nu tit al-so fill out the section below showing their workers'compen%ation policy mlonnation. t I lotneowners who submit this aftidavil indicating they are doing all work and then hire outside contractors must suhmit a new affidavit indicating such. .Contractors that check this box must attached an additional sleet showing the name of the sub-cwntrctenors and stale whether or not those entities have employees Il'the sub-contractors have employers,they must provide their workers'amtp.1vitcy numbm I nm an eutployer d►at iv providing worlierc'c•ontpensation insurance for r►ty employees. Belc►w is the policy and job site information. Insurance Company Name: Liberty Mutual Policy H or Self-ins.Lic.N:WC531 S620647019 — L:xpiration Date: 2/1/2020 Job Site Address: I rl Parr- R I lJL 0 City/State/Zip; Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA flor insurance coverage verification. I do hereby certify and t ahis and/pe ltles 0 r a infornmtion provided above is true curd correct. Signature: v Date: /0 - Phone n: 413-584-8844 Oficial use on6. Do not write in this area,to he completed by city or town of ficiaL City or Town: Permit/License# _ Issuing Authority(circle one): 1. Board of Health 2. Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other __ T Contact Person: Phone It: City of Northampton � Massachusetts DEPARTMENT OF BUILDING INSPECTIONS � r �$ 212 Main Street *Municipal Building ,r Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 137 Park Hill Rd (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) Signature of Permit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. *Penn FUSION 1 52 S. Broad E n y 1 n ® s it l n y Lansdale, PA 1944466 (215)361-8040 October 23, 2019 Valley Solar 340 Riverside Dr Northampton, MAO]062 RE: George Residence 137 Park Hill Rd, Northampton, MA 01062 Client Project#: 137GEOR PFE Project#: 194335 On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads.Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size: 7 kW/DC Panel Specs: (20) LG Solar- LG350N1 C-A5 Inverter Specs: (20) Enphase-IQ7+ Racking System: SNAPNRACK- UR The modules are to be located on the following roof plane: Mounting Rafter Rafter Horizontal Collar Collar Tie Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Sheathing Type Shingle Layers Profile 1 2x6 16" 12ft. 1 1 in. N/A 0" CDX 1/2" Asphalt 1 Flat Shingles The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows: Ground Snow(Pg): 40 psf Wind Speed (V): 1 1 7 mph Mounting Plane 1 The calculations for these structural members are attached. It has been determined by this office that the roof, as specified above, is adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16"lag bolts at 48 on center maximum with staggered penetration such that load is distributed evenly among roof members. Provide a minimum of 2" of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. �P`ZNOFIti, Best Regards, �,� 0 Penn Fusion Engineering LLC o AN EW aONEVC R, J LEO%E NO 53044___._ Andrew D. Leone, P.E. , \� Principal ST£ SS�ONAL��' Penn FUSION 1 52 S. Broad 0 E Tl 9 1 n ® e r I Tl y Lansdale, PA 1944466 (267)640-2758 Client Name: Valley Solar PFE Project Number: 194335 Client Project Number: 1 37GEOR Project: George Residence Address: 137 Park Hill Rd Northampton, MA 01062 Description: Mounting Plane 1 Calculations By: ADL Date: October 23, 2019 Roof Construction 2x6 Rafters at 16"on center A= 8.25 in' Ix= 20.8 in Sx= 7.56 in Wood Species= Doug-Fir Larch#2 Fb= 900 psi Fv= 180 psi E= 1600000 psi Roof Slope= 34 ° Rafter Span= 12.94 ft Ceiling Attached to Rafters?: No Design Criteria Ground Snow(Pg): 40 psf Design Wind Speed: 117 mph Live Load: 20 psf Dead Load: 4.91 psf PV Modules: 3.62 psf Wind Calculations Directionality Factor(Kd): 0.85 Topographic Factor(K,t): 1 Velocity Pressure Exposure 0 7 Coefficient(KZ): Importance Factor(1): 1 Velocity Pressure(qz): 20.85 psf Tributary Square Footage on 10.83 ftz Component: Component Roof Pressures: 22.45 / -28.63 psf Snow Load Calculations Exposure Factor(Ce): 1 Thermal Factor(Ct): 1 Importance Factor(1): 1 Flat Roof Snow Loads (Pf): 35 psf Roof Slope Factor(CS): 0.9 Sloped Snow Loads (PS): 31.5 psf Unbalanced Snow Load: 0 psf Member Calculations Bending Md: 941.77 ft*Ib fb: 1494.38 psi Load Duration Factor(Cd): 1.1 5 Stability Factor(CO: 1 Wet Service Factor(CM): 1 Temperature Factor(CT): 1 Size Factor(CO: 1.3 Flat Use Factor(Cf„): 1 Incising Factor(C): 1 Repetitive Member Factor(C,): 1.1 5 Fb: 900 psi F'b: 1547.33 psi 1494.38<=1547.33 OK in Bending Shear Vd: 291.06 lb f,: 52.92 psi Load Duration Factor(Cd): 1.1 5 Wet Service Factor(CM): 1 Temperature Factor(CT): 1 Size Factor(CO: 1.3 Flat Use Factor(Cf„): 1 Incising Factor(C;): 1 Fv: 180 psi F'v): 207 psi 52.92<=207 OK in Shear Deflection Live Load Deflection A): 0.64 in L/244 OK in Live Load Deflection Total Load Deflection (AT): 0.85 in L/182 OK in Total Load Deflection Uplift Calculation Tributary Square Footage on 10.83 ftz Component: Uplift Pressure: -28.63 psf Uplift per Lag: -310.15 lbs Lag Screw Diameter: 5/16 in Allowable Withdrawal per Inch: 490.99 lbs/in Minimal Screw Penetration: 0.63 in Install 5/16"diameter lag screws @ 48 on center with minimum penetration of 2" into rafter. w S � a h. t7 t v a Lu oa w �.a OJz .. •+�.. �„ - EDS w puia a 3 Y � dL Y r.. � f ✓Y l � t!J N fTq PLAN LEGEND ROOF ARRAY 20x LG350N1C VS SOLAR PV PANELS Z 1 • �c, w "' �+ 20xENPHASE IQ7PLUS-72-2-US g MICRO-INVERTERS a r SNAPNRACK ULTRA RAIL SOLAR w a �► e C .J MOUNTING SYSTEM INTERNAL WALL OF HOUSE k a, SOLAR PV COMBINER BOX(N) AC DISCONNECT(N) MAIN ELECTRICAL PANEL(E) M EXTERNAL WALL OF HOUSE 0 Q ® MA SMART GENERATION METER(N) AC DISCONNECT(N) o UTILITY METER(E) m a Utility Client: COLLEEN E GEORGE > a , 137 PARK HILL RD LOT 1 L1 NORTHAMPTON MA 01062 it m MCA TMa pl«rV tl«prtprnM1ry xern nrbNlcl d KNeY Mane Mi!r^«n,Mc.(7MII.n q dstirared br Iw NnMW W exdusiw gxpue d cuppMig nre caAac!6d dVN1.«M w6arxv epaa mar ma ek+roms d Ihs ylan MCII mJ w reWQYawd axpeeenfed v�am Mm Nr ms wwa.d en.yMy a v+ppOrUnp Ne•vrk aI cmV.tl i propel carWectan.uV.oIN rlis pxm"+aim d,sM!cWrpnanbiv�peN b,VMI. Z D O Z \ q r O� 4 z— U �' m w _ QQ�mro Or x 6 O N T S4 6 f 6. m RRS tie6� aF a.�?i tl Lr C p6� !1^7 9 QLP.—tO She i 'S�y c 0 r" a zi a C.s E. IViC m��' rc� �a �� eY L6 s�s6 • ;fie s� 6ya• 8i� g6 x= �� s�lz�,€g� Ya r:6 Quo e.�o� ss F cf a S$6 R4 ss. If 10>dO4Cfs7 ValleValley Solar LLC 1340 Rivers de Drive SITE NAME COLLEEN E GEORGE scn�:sEE� SREEI NUMBER Y PO Box 606271 Northamplor, PLOT LINES SITE ADDRESS 137 PARK HILLR . oAtE;ransna MA 01062 1413.584.8844 NORTHAMPTON MA 01082 S car --ValleySoler.Solar SYSTEMS12E 7.OkWDC 5.8kWAC DRAW LR AC Isolation Device between LINE on the top and the LOAD on the W . . . . . . . . . . Company meter&DER bottom side of the MA SMART Meter MOD 10MICRO MOD MOD MOD 1 � I m 2 y 8 l INVERTERS IN BRANCH 5 1 2 V5# ervice Panel AC Ca e MART 3 SMeter AC Isolation Device—> AC AC Combiner Box _ AC AC 1 a DC DC DC DC 4 n a 3-sox ^ 6 5 4 5 n 6 q 10 11 ui tj s 0 MOD MOD MOD MOD n AC Disco To/From o M aD 10 kWh r\ kWh Utility ,=p M M uJYa g MICRO (4)#10/3 2vJo Lu e s INVERTERS (1)#10 Green A pCB to = IN BRANCH IN 3!4"EMT 10/3 RX 10/3 RX 10/3 RX J o CIRCUIT. 11n<pdese1 Mem 8 q Z AC _ AC AC AC FaooueTion eTe 0Ee wN 's DC DC DC DC a _ �a w (1)#6 CU THHN (2)#12 CU THWN-2. ~t= F EGC O Cable m rn h Utility Info: Communications: ConductorlOCPD Calculations: Utility Company:National Grid Q Wifi to Envoy or CAT5 TBD Utility Acct#:88871-34007 (NEC 210.19(A)(1)(a)).Inverter IQ7PLUS-72-2-US p Meter*83045416 Max Output=1.21A x 20=24.2A x 1.25=30.25 A Customer:COLLEEN E GEORGE v E a O 137 PARK HILL RD LOT 1 L1 cc Equipment Schedule NORTHAMPTON MA 01062 ~ Labelinfl Schedule ❑ J �g $ 1 RACKING(Ultra-Rail)Snap N Rack Roof Mount System Inverter Trip Settings: 1.WARNING!PHOTOVOLTAIC POWER SOURCE w 1 2 MODULE LG350N 1 C-V5 20x panels.Max output 41.3V/ Inverter TRIP settings are set in the inverter per the ISO NE SRD and ESB 756 section ( ) p p 7s.11. 2.SOLAR PV AC COMBINER BOX 10.61A DEVICE DEFAULT PICKUP DEFAULT CLEARING Pickups and 3.PV SYSTEM AC DISCONNECT Rated AC Output Current: a E 3 MICROINVERTER(IQ7PLUS-72-2-US)20x Enphase IQ7+. SETTING TIME(seconds) Clearing Times 24.2AAC Nominal Operating Voltage:240V AC s.2 (simplified defaults Adhere to Max output 240VA/1.21 A from section 7.6.1,) Required Defaults 4.RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM i Y 4 SOLADECK(0799 Series)3R Rated Flashed pass-thru (Yes)No): 5.WARNING!ELECTRICAL SHOCK HAZARD TERMINALS $ enclosure. Under Frequency 56.5 Hz 0.16 res ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED t 5 AC COMBINER(X-IQ-AMI-240-3)2x AC 20A Breaker/branch. (etc) IN THE OPEN POSITION B m a Max 80A.5A breaker to feed Enphase IQ Envoy GatewayUnder Frequency 56.5 Hz 300 Yes p y alu) 6.UTILITY GENERATION METER 12 it production CTS&RGM Over Frequency 61.2 H: 300 res 7.WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES a S MA SMART GEN METER(U5934)Socket installed for Utility's (e,o) UTILITY GRID AND PHOTOVOLTAIC SYSTEM SMART Generation meter over Frequency 62.0liz 0.16 Yea ° 7 AC DISCONNECT(DG222URB)60A 240VAC(adjacent to (810) 8.WARNING.) INVERTER OUTPUT CONNECTION DO NOT utility meter) Under Voltage(27) 50%ofNominal 1.1 yen RELOCATE THIS OVERCURRENT DEVICE Lr Under Voltage(27) ee i of Nominal 2 Yes 9.SOLAR PV ;0-1Cd $SERVICE PANEL 200A MAIN,200A BUS.System OCPD 2P Over Voltage(59) 0%of Nominal 2 Yes 10.WARNING!UTILITY METER ENERGIZED BY 2 35A CB ,Q UTILITY METER 120/240V, 1PH,3W OvervdUge(sg) 120%ofNominal o.1e reg SOURCES 11.UTILITY SERVICE METER THIS ELECTRICAL 113 A PROPOSED DESIGN.THE ELECTRICIAN IS AT LIBERTY TO ADJUST DURING THE 91JRD AND AMENDMENTS N61 BE REFLECTED N THE A"8 TMallt M. e( e 3` LG350N 1 C-V5 350W The LG NeON°2 is LG's best selling solar module,and is one of the most powerful and versatile modules on the market today.Featuring LG's Cello Technology,the LG NeONO 2 increases power output.New updates include an extended performance warranty from 86%to 90.08%to give customers higher performance and reliability. imiucr C&us YEAR t, Features Enhanced Performance Warranty Enhanced Product Warranty f 25yr- `s LG NeON6 2 has an enhanced LG has extended the warranty of the performance warranty.After 25 NeONO 2 to 25 years including labor, years,LG NeON®2 is guaranteed at which is top level in the industry. least 90.08%of initial performance. Better Performance on a Sunny Day Roof Aesthetics LG NeON',"'2 now performs better on LG NeON%2 has been designed with sunny days,thanks to its improved aesthetics in mind using thinner wires temperature coefficient. that appear all black at a distance.The LG NeONO 2 can increase the aesthetic value of your home with a more modern design. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics LG Elect—c-a global lead—n electronic products in the dean energy markets by offering solar PV panels and energy storage system:.The company first embarked on a solar ,9 energy cts re oursearch program In 19E5,supported by LG Group's vast eupenence in the sem�•conducto�;LCD,chemistry slid nn—,WL mdustnes.In 1010,LG Solar successfully 5 e" - released its first MonoXis cedes to the market,which,s now available in 32 countries.The NaONa(pre-us MonoNO NeON),NeON62,NeON.1 Biracial won the"Intersolar ,. + „ Solar AWARD"in 1013,2015 and 2016,which demonstrates LG's leadership and mno-t-,in the solar industry. L6350NlC-V5.lndd 1 6127119 1:02 PM LG NeOW2 LG350N1C-V5 Preliminary General Data Electrical Properties(STC*) Ceti Pmpertles(MatmUlL/Type) Monocrystalline/N-type Model _ LG350N1 C-VS Cell Maker LG Maximum Power(Pmax) [Wj 3S0 Cell Configuration 60 Cells(5 x 10) MPP voltage(Vmpp) IV] 35.3 Number of Busbars 12EA MPP Current(Impp) - JA) - 9.92 __.._._._ _._..__-._-.___ .._ _._......._ _... -_.. _____. ___..... _._._ .. - _......_..-.. _ _ - ___. Module Dimensions(L x W x H) 1,686mm x 1,016mm x 40 mm Open Circuit Voltage(Voq 5%) [V] 41.3 Weight 17.1 kg Short Circuit Current(Isc,-5%) [A] 10.61 Glass Material Tempered Glass with AR Coating -- - -(Material) _ P_e 9 ModWe Efficiency � [%] 20.4 Bxksheet(Coku) White __ --. ... - _ .. -..-.- -. _. .. _- _._.. PowerTderance [%] � 0-«3 Fmxe(Material) Anodized Aluminium •STC(Standard Tea Condition}Irradiance 1000 W/m',all temperature 25'C,AM I.S.Measure Tolerance:=3% Junction Box(Protection Degree) IP 66 with 3 Bypass Diodes i_. .. -..s 061es(Letigtli) 1,000m rl Operating Conditions CWd*CtDrCrype/Maker) MC 4/MC Operating Temperature (Y] 40-i 90 Maximum System Voltage [Vj 1000(IEC) Maximum Series Fuse Rating [A] 20 Certifications and Warranty — Mechanical Test load•Front ( ) (Pa/psfJ 5,400/113 IEC 61215.1/-1-ln+.2016,IEC 61730-1/2.2016 - Mechanical Test Load*(Rear) [Pa/psf] 4,000/84 Certifications ISO 9001,ISO 14001,150 50001 'Meclunial Test Loads 5,400 Pa/4,000 Pa based on IEC 61215-2:2016(TestLoad-Design Load x Safety OHSA518001 Faaur(1.5)) salt Mist Cwt on Test IEC61701:2012Severity6 - _ _--- _ ..... __-- Packaging Configuration Ammonia CorrosionTest IEC 627162013 ------ ------ ---- — - —. Number of Modules per Pallet EA 25 Fire Rating Class C(UL 790) -- -- ----- -- " -o- ___. Number of Modules per 40ft HQ Container [EA] - 650 Solar Module Product Warranty 25 Years ___._.. -._ ___ _-....-_._._ _ Packaging Box Dimensions(L x W x H) [mm] : 1,750 x 1,120 x 1,221 Solar Module Output Warranty Linear Warranty - _. _ _. - _. _. _ 'Improved.1st year 98%from 2-24th year 0.33%/year down,•Rer 25th year 90.08% .Packaging Box Gross Weight_ [kg] 464 Temperature Characteristics Dimensions(mm/inch) NMOP - 1 (Y3 ! 42 3 3 Pretax , IM] -0.36 Voc IKIC] -0.27 ioie.vxo.o Isc C%rcl 003 ex.olae.. •NMOT(Nominal Module Operaaig Temperature)Irradiance 800 W/m2,Amb4m,temperature 20-C, Wind .:ii ns 0— n.n nd speed 1 m/s,Spectrum AM 1.5 arwd�.p wvi.. ira«i Electrical Properties(NMOT) Model LG350NIC-VS Maximum Power(Pmax) [W] 261 MPP Vdtagr(Vmpp) [V] 33.0 MPP Currem(Impp) [Al 791 Open Circuit voltage(Voc) [V) 38.80 Short Circuit Current(Isc)_.(A] 8.53 cmi.trwM i IN Curves yl r �l $: sl �, rvtiv t .w a 3:060 _..._..—_.� c CGvw U rcnVr 1 _ a 0 0 I p LO 10.7 'ri0 -U.0 il10 \/.-,IrlgF(V) LG Electronics Inc. Product specifications are subject to d-ge mmhout nouce. LG Solar Business Driven J`4 (8 2000 Millbrook Drive LG350N1 C-V5 ��••yy_#� Lincolnshire,IL 60069 i.+ r Life's Good wwwlg-solaccom 0 2019 LG Electromcs.All rights reserved. ❑M F:._ .i L0350N1 C-V5.lndd 2 6/27/19 1:02 PM Enphase The high-powered smart grid-ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro" Q 7 and IQ 7+ dramatically simplify the installation process while Microinverters achieving the highest system efficiency. Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery'", and the Enphase Enlighten'"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) The IQ 7+Micro is'required to support 72-cell modules. U` To learn more about Enphase offerings,visit enphase.com � E N P H AS E Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27V-37V 27V-45V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port 11 II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/rangez 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging 99 9 EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at htips://enphase.com/en-us/support/module-compatibil ly. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v E N P H A S E, ©2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc 2019-3-26 SNAPNRACK UR-40 RACKING SYSTEM SNAPNRACK REVISION: VISI2017 MAMNL-JIL SHOWN MOUNTED ON ULTRA FOOT WITH MID CLAIM, UNIVERSAL END CLAMPS.FOR TILE TYP. — — ROOFING USE SNAPNRACK TILE "RAIL END OVERHANG" — REPLACEMENT,UNIVERSAL TILE HOOK OR NOT TO EXCEED 34%OF —_ FLAT TILE HOOK SYSTEMS. ACCEPTABLE RAIL SPAN — STANDARD LAG SCREW SPEC ASSUMES SNAPNRACK UNIVERSALASSEMBLY, END CLAMP ASSEMBLY,TYP. \,y '&"0 LAG SCREW WITH 2Y,"MIN. EMBEDMENT INTO STRUCTURAL MEMBER. TORDUE SPECIFICATIONS: SNAPNRACK ROOF ATTACHMENT s/e"0 NUTS&BOLTS,10-16 FT-LBS SNAPNRACK UR-40 RAIL,TYP. (MODULE HIDDEN FOR CLARITY) RAILS CAN BE MOUNTED ON EITHER SIDE OF ULTRA FOOT;UPSLOPE OR DOWNSLOPE. DEWL A FOR UNEVEN ROOF SURFACES,UTILIZE THE SNAPNRACK LEVELER EXTENSION "RAIL IS AS LEVELING SPACER.SEE DETAIL(S) SPAN" DEFINED "UR40-D01,""UR40-D08,""UR40-DO9,"8 DISTANCE BETWEEN LIMITATIONS.FOR DETAILS AND ROOF ATTACHMENTS LIMTIONS. 'STRUCTURAL MEMBER(S)' � MAY REFER TO RAFTERS,PURLINS, BEAMS,OR OTHER STRUCTURAL, LOAD-CARRYING MEMBERS SNAPNRACK MID CLAMP,TYP; CLAMP ASSEMBLY SHALL BE SELECTED TO MATCH PV MODULE "MODULE OVERHANG" NOT TO EXCEED 25%OF MODULE LENGTH OR MODULE MANUFACTURERS RECOMMENDATIONS SNAPNRACK ROOF ATTACHMENT LAG SCREWED INTO STRUCTURAL MEMBER. NO FLASHING SHOWN FOR CLARITY. Sunrun South LLC DESIGNER: M.A((entra_n of [DA DNS PART NUMBER: DESCRIPTION: \��UU ^�• �• `"W DRAFTER: M.Affentra.__nn( UR40-D06 UR-40 TYPICAL LAYOUT J' A olar Mo ng Solutions'. 30/zOL7 APPROVED BY: &MCPheeGers_ SNAPNRACK UR-40 RAIL SHOWN SPLICED REVISION: TOGETHER WITH THE SNAPNRACK ULTRAIlnrzat7 tIV DETAIL _�, RAIL SPLICE. 2"MIN --�._2"MAX--I "•�"RAIL GAP - rOR THERMAL EXPANSION - — mESPECIFICATIONS: -----------y--AT SPLICES NUTS 8 BOLTS,10-16 FT-LBS ---- CENTER SPLICE BETWEEN THE TWO BONDING CLIPS AS SHOWN IN"SPLICE 4 ALIGNMENT LIMITS"VIEW RAIL EDGE MUST NOT Pwss- SPLICE ALIGNMENT LIMITS THE CLIP EDGE,AS SHOWN, ----SNAPNRACK UR-40 RAIL, TYP. SNAPNRACK BONDING CLIP,TYPE 2 8 FOR BONDING ACROSS RAILS SY,a"0-18 BOLT,S.S. SNAPNRACK ULTRA SPLICE ASSEMBLY, CENTER ON RAIL GAP f 1" i SNAPNRACK ULTRA SNAPNRACK ULTRA SPLICE,TAPPED SPLICE,THRU _ Sunrun 6outh LLC DESIGNER: M.Affentranoer SCALE: DNS PART NUMBER: DESCRIPTION: REV DRAFTER: M.AffentranDer UR40-D0 5 UR-40 ULTRA SPLICE DETAILS A Solar Mobnting Solutions APPROVED BY: GNcPheeOas — DATE: 11/7/2017