Loading...
38B-149 (3) 49 COLUMBUS AVE BP-2020-0197 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38B- 149 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0197 Proiect# JS-2020-000331 Est.Cost: $33945.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: DEVLIN CONTRACTING & MAINTENANCE 111884 Lot Size(sq. ft.): 5619.24 Owner., RUSSO MARGARET Zoning:URB(100)/ Applicant: DEVLIN CONTRACTING & MAINTENANCE AT: 49 COLUMBUS AVE Applicant Address: Phone: Insurance: 86 FINNELL DRIVE SUITE 21 (781) 812-0420 Workers Compensation WEYMOUTHMA02188 ISSUED ON.8/15/2019 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF MOUNTED SOLAR, 30 PANEL 9.30 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/15/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272' Louis Hasbrouck—Building Commissioner Department use only `- City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit A 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans r� phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE ORD LI H A ONE OR fwo IIAMILY DWELLING G SECTION 1 -SITE INFORMATION 1.1 Property Address: rvoRrH htjF pPAA 01060 com leted by office c/ &)1t111)hx Aff Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: r����t� Lira yq ame Pri Cu in Telephones L SignatureC..)(tI p 7 2 Authorized Agent: I UJCJ //��� r 21 r Name(Print) Current Mailing Ad ress�: Signatu Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a)Building Permit Fee 2. Electrical CIO', (b)Estimated Total Cost of LI D Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total = (1 +2+ 3 +4 + 5) Check Number This Section For Official Use Only Date Building Permit Num er: Issued: Signature: �-L6 J c( Building Commissioner/Inspector of Buildings Date EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) Section 4. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding er been issued for/on the site? NO O DON'T KNOW YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO (!)/ DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained O Date Issued: C. Do any signs exist on the property? YES V NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [M 'ging[0 Me 2r Brief Desq tion of Propos d Work:-:-5(---3 En/(� /�1IGrD i�Vf l/C>� Sl �gldJc-� Uyf7CM Alteration of existing bedroom Yes No Adding new bedroom J Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property hereby authorize to act on my alf, in all matters relative to work authorized bythis building permit application. Signature of Owner Date rf as Owner/Authorized Agent hereby declare that the statements k@yd information on the foregoing application are true and accurate,to the best of my knowledge and belief. Si n ad under the pains and penalties of perjury. Pri lJ C Signat re of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder .Q Cil ' &—&ie License Number dress f Expiration Date 3/- eJ2, 62416 Sig'natuN Telephone n—Istemd Hom Cordractor, Not Applicable ❑ ��Cvh.n Cmto( nnaM11ZW__e 18Z25b91 Comaan% Name Regis ration Number s A ress -7 Expiration Date Telephone G- SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ City of Northampton r �• 30_ f!f Massachusetts 't DEPARTMENT OF BUILDING INSPECTIONS �`- v� 212 Main Street • Municipal Building Northampton, MA 01060 SNjyjj�� AFFIDAVIT Home Improvement Contractor Law Supplement to Permit Application The Office of Consumer Affairs and Business Regulation("OCABR")regulates the registration of contractors and subcontractors performing improvements or renovations on detached one to four family homes. Prior to performing work on such homes, a contractor must be registered as a Home Improvement Contractor("HIC"). M.G.L.Chapter 142A requires that the"reconstruction, alteration, renovation, repair, modernization, conversion, improvement, removal, demolition, or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units....or to structures which are adjacent to such residence or building"be done by registered contractors. Note:If the homeowner has contracted with )a corporation or LLC, that entity must beereggi}steregistered.Type of Work: �,CV l l/ Est. Cost:3 %V> ' 60 Address of Work: t/1 C�>>c� s � r �, W t�/UtGL� Date of Permit Application: i I hereby certify that: Registration is not required for the following reason(s): _Work excluded by law(explain): _Job under$1,000.00 _Owner obtaining own permit(explain): Building not owner-occupied Other(specify): OWNERS OBTAINING THEIR OWN PERMIT OR ENTERING INTO CONTRACTS WITH UNREGISTERED CONTRACTORS OR SUBCONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK ARE NOT ELIGIBLE FOR AND DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER M.G.L.Chapter 142A.SUCH OWNERS ALSO ASSUME THE RESPONSIBILITES FOR ALL WORK PERFORMED UNDER THE BUILDING PERMIT.SEE NEXT PAGE FOR MORE INFORMATION. Signed under the penalties of perjury: I hereby apply for a building permit as the agent of the owner: Date Contractor Name HIC Registration No. OR: Notwithstanding the above notice, I hereby apply for a building permit as the owner of the above property: Date Owner Name and Signature City of Northampton Massachusetts DEPARTMENT OF BUILDING zNaPEcrzouS uzu main Street *Municipal a"izuinn Northampton, m^ uz000 Debris �� �~� ~ ����^«~����� ~� Affidavit� =����� ~ �~ �� �� �� Disposal ���� J� ������ � �� �� �� .� w� �� In accordance of the provisions of yWGL o4U. S54. | acknowledge that as m condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by IVIGL c 111, S 150A. The debris from construction work being performed at: -Yq C6A1'0&( Z4 VC, (Please print house number and street name) |otobadisposed ofat: ' �Q s��_�- ^ p-� 621Ea (Please print name and location of facilityl Orwill bedisposed ofinadumpmtmronsite rented orleased from: (Company Name and Address) Sigg nat ermit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constrg:Cdtbri 1§b0grvisor CS-111884 i j�g Folres:08/2112021 f BENJAMIN T O'CONNELL' 74 BAYVIEW AVE QUINCY MA 02168 Commissioner 9�ia �..nnoie /'o�.�iLs1�c�.Jelld Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR TYPE:Supplement Card Registration valid for individual use only Registration Expiration before the Office of Consiration umer Affairs airs and Business Regulation ate. if found return to: 182869 i 08/0312021 10 Park Plaza-Suite 6170 DEVLIN CONTRACTING AN[i INTENANCE INC. Boston,MA 02116 r '* R BENJAMIN O CO N LL 86 FIN NELL DR#21 ro✓� `�` �f` WEYMOUTH,MA 02188 Undersecretary Not Vali without signature M The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): 1DevIin Contracting&Maintenance Address: 86 Finnell Dr.Ste.21 City/State/Zip: Fe- mouth,Ma 02188 Phone #; 781-812-0240 Are you an employer? Check the appropriate box: Type of project(required): 1. I am a employer with 15 4. 0 I am a general contractor and I 6. [1 New construction employees(full and/or part-time).* have hired the sub-contractors 2. I am a sole proprietor or partner- listed on the attached sheet. * 7. E)Remodeling ship and have no employees These sub-contractors have 8. ® Demolition working for me in any capacity. workers' comp. insurance. 9. E]Building addition [No workers' comp. insurance 5. El We are a corporation and its officers have exercised their 10.�Electrical repairs or additions required.] 3.E] I am a homeowner doing all work right of exemption per MGL 11.® Plumbing repairs or additions myself. [No workers' comp. c. 152, §1(4), and we have no 12.[0 Roof repairs insurance required.] t employees. [No workers' 13.El Other Solar Install comp. insurance required.] Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and their workers'comp. policy information. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Guard Insurance Insurance Company Name: Policy #or Self-ins. Lic. #: Expiration Date: 04/03/2020 49 Columbus Ave. iNorthampton,Ma 010E Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify unde e p in and penalties of perjury that the information provided above is true and correct. 08/13/2019 Si nature: �___ Date: Phone#: 781-812-0240 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: DEVLCON-01 MGQMEZ '4`� CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIVYW) 4/22/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). C NTACT PRODUCER M R.S.Gilmore Insurance (, ,,No,Ext;(508)699-7511 n/c,No:(508)695-3597 27 Elm St E-MAI North Attleboro,MA 02760 INSURERS AFFORDING COVERAGE NAIC# INSURER A:EMC Insurance Companies 25186 INSURED INSURER B:AmGuard Ins CO Devlin Contracting&Maintenance,Inc. INSURER C: 86 Finnell Drive -INSURER D: Weymouth,MA 02188 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR WVDPOLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRA X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE 1'000,000 CLAIMS-MADE [X OCCUR 6D02139 3/20/2019 3/20/2020 DPREMfSESE,AMAGE TORENT occurrence) $ 500 000 MED EXP An one person) 10,000 PERSONAL&ADV INJURY $ 11000,000 �'OTHER: LAGGREGATELIMITAPPLIESPER: GENERALAGGREGATE $ 2,000,000 POLICY 1:1 jpa �LOCPRODUCTS-COMP/OPAGG $ 2,000,000 COMBINED SINGLE LIMIT 1,000,000 A AUTOMOBILE LIABILITY ANY AUTO SZD2139 3/20/2019 3/20/2020 BODILY INJURY Per erson $ OWNED X SCHEDULED BODILY INJURY Per accident)AUTOS ONLY AUTOS SSyyN R X AUTOS ONLY X AUTOS ONLD PPerOapcEcideTMnt AMAGE $ A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE 5,000,000 EXCESS LIAB CLAIMS-MADE 6JO2139 3/20/2019 3/20/2020 AGGREGATE $ 5,000,000 DED I X I RETENTION$ 10,000 B WORKERS COMPENSATION PERTUTE OTH- AND EMPLOYERS'LIABILITY YIN R2WC014523 4/3/2019 4/3/2020 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT 111 WICCER/MEMB�E�REXCLUDED? N/A 1,000,000 ndatoryin NH) E. DISEASE-EA EMPLOYE $ IF yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN For Informational Purposes ACCORDANCE WITH THE POLICY PROVISIONS. Only AUTHORIZED REPRESENTATIVE 3 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD O (I& INSIGHT ... Homeowner's Authorization to File Permits I, GCC Y EUSSD am the owner of the property located at address: y!2 Cd&2bi 4L. aOYMA O/UCO I here va u1borize Insight Solar and their subcontracting company to act as my agent for the limited purpose of applying for and obtaini local building and other permits from the Authority Having Jurisdiction as required for the installation of a PV solar electric system located on my property. This authorization includes the transfer/re- administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Homeowner's Signature: Printed Name: mom Date: 05/29/2019 Insight Solar 180 Pleasant St. Suite 2 413-338-7555 Doc ID:c2686lcObc234c04blc377bbdde45cfd02b95a43 AIJDLXC DESIGN 409 N. MAIN STREET ELMER. NJ 08318 (856) 712-2166 FAX. (856) 358-1511 Construction Code Office Date: August 9, 2019 Re: Structural Roof Certification Subj: Russo Residence,49 Columbus Ave.,Narthhampton,MA 01060 We have provided a review of the house roof construction of the above named property in regards to verifying the capacity of the existing roof for installation of a new Solar Panel Array. We have found the residence to be of wood frame construction bearing walls with a rafter framed roof system. The Array is of 2x4 @ 16"o.c.rafter framed roof with knee walls and sheathed with '/i ext-ply sheathing and a single layer of composite shingle roofing. The wood framed roof structure bears directly upon the framed exterior wall system. The existing rafters as installed meet (MA 780 CMR 9`h edition) IRC-2015 with MA Amendments design span ratings with sufficient capacity to carry the 4#/sf additional load imposed by the proposed solar array per the details below. Installation of solar rack systems shall be as follows: Each panel row shall be supported upon 2 mounting rails. Rails shall be screw anchored through roof and directly to rafters or purlins below or by multiple fasteners to the roof sheathing. When attaching to rafters, use IPC 5/16" x 4" ss lag or equivalent or if when attaching to cheating,use 4 pcs'/4"x 2"ss lag or equivalent. Rail attachments to roof shall be fastened 24"o.c. maximum at corners and 48"o.c. maximum through the field. When installed per the above specifications the system shall meet the required 120 MPH wind load and 35 PSF ground snow load requirements. Should you have any further question or comment please feel free to contact our office. Respectfully, of Oti JAMES O CLAN No.46775 y James A.Clancy 9FvIsIr Professional EngineerALtc�C> MA License#46775 A B C D E F G H GENERAL NOTES A SHEET LIST TABLE 1'1'1 PROJECTNOTE6: NEW PV SYSTEM. V.300 kWp SHEETNUtdB'R SHEET TITLE !�INeI�I�T 1 11.2 THIS PHOTOVOLTAIC IPV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE 690. ALL T-001 COVER PAGE MANTHE RELEVANT CODES AS AND INSTALLATION BY INSAUTHORITY HAVING RU SSO RESIDENCE ' N°�` THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. A-101 SITE PLAN 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 49 COLUMBUS AVE X102 ELECTRICAL PLAN CONTRACTOR 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION(GFDI)DEVICE IS A-103 SOLAR ATTACHMENT PLAN INTEGRATED NTH THE MICROINVERTER IN ACCORDANCE WITH NEC 69041(8' NORTHAMPTON MA 01060 E-602 LINE DIAGRAM INSIGHT SOLAR 2 1.1.5 ALL PV SYSTEM COMPONENTS;MODULES.UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE I E-602 DESIGN TABLES 1II1 PHONE: 413-33&7555 IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS ASSESSOR'S Tf: NHAMM:038BB:0149L.0001 E-603PLACARDS ADDRESS:180 PLEASANT ST,SUITE REQUIRED BY NEC 690.4: PV MODULES.UL1703.IEC61730,AND IEC61215,AND NFPA 70 CLASS C 5501 ASSEMBLY DETAILS EASTHAMPTON,MA 01027 FIRE INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 ,� 5502 ASSEMBLY DETAILS LIC.NO: MA 192102 COMBINER BOX(ES):UL 1703 OR UL 1741 ACCESSORY R-001 RESOURCE DOCUMENT 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED NIC.NO.: TEMP COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE R-002 RESOURCE DOCUMENT ELE NO.: UNAUTHarMZED Use OF THS CALCULATED ACCORDING TO NEC 690.7. R-W3 RESOURCE DOCUMENT DMMNGSErWTHOUTwwTTEN 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, PEWSSION FROM CONTRACTOR IS IN AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A R-004 RESOURCE DOCUMENT NOLOMOP U.S.COPrwONTUWS M N1LL BE SUBJECT TO CNB 3 PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED /// m ES AND PROSECUTMS.FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED R-005 RESOURCE DOCUMENT ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING R-006 RESOURCE DOCUMENT NEW PV SYSTEM:9.300 kWp INEC 110.31 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING - CODE IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL R V SSSVD PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. PROJECT INFORMATION RESIDENCE 1.2.1 SCOPE OF WORK: 49 COLUMBUS AVE 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND OWNER NORTHAMPTON,MA 01060 SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM NAME: MARGRETRUSSO RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR AERIAL PHOTO APN:NHAMM:038BB:0149L:0001 PROJECTNAKAGER COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,SPECIFY, 4 AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THENAME: ERIC WILSON PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. NOT TO SCALE PHONE: 413.338.7556 ENGINEER OF RECORD 1.3.1 WORK INCLUDES: 1.3.2 PV ROOF ATTACHMENTS-UNIRAC FLAT FLASHING,ECOFASTEN C CONTRACTOR ECOFOOT5 KNAME: INSIGHT SOLAR 1.3.3 PV RACKING SYSTEM INSTALLATION-UNIRAC SUNFRAME RAIL 5PHONE: 413338-7555 1.3.4 PV MODULE AND INVERTER INSTALLATION-CERTAINTEED SOLAR CT31DM10.03 I ENPHASE 107-50.2-US ^ AUTHORITIES HAVING JURISDICTION 1.3.5 PV EQUIPMENT GROUNDING / \ BUILDING HAMPSHIRE COUNTY .3 PV PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX Z ZONING: HAMPSHIRE COUNTY 1.3.7 PV LOAD CENTERS OF INCLUDED) UTILITY: 1.3.8 PV METERINGKJOMTORING(IF INCLUDED) 5 1.3.9 PV DISCONNECTS / > DESIGN SPECIFICATIONS PAPERSIZE:n-.(r(ANSIB) 1.3.10 PV GROUNDING ELECTRODE 8 BONDING TO(E)DEC OCCUPANCY 11 1.3.11 PV FINAL COMMISSIONING / CONSTRUCTION: SINGLE-FAMILY COVER PAGE 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV /\ ZONING' RESIDENTIAL 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE GROUND SNC)W LOAD: 35 PSF i y SCOPE OF WORK `� i '` WIND EXPOSIdtE B DATE: 07.23.2019 SYSTEM SIZE. STC:30 X 31 OW=9.306KW WIND SPEED 120 MPH DESIGN BY:V.D. PTC.30 X 287.06W=8.612KW DC (30)CERTAINTEED SOLAR CT310MIO-03 APPLICABLE CODES 8 STANDARDS CHECKED BY: M.M. (30)ENPHASE107-60-2-USN BUILDING: MASSACHUSETTS RESIDENTIAL BUILDING PLATMAP CODE,9TH EDITION.AS AMENDED 980 CMR) REVISIONS 6 ATTACHMENT TYPE: UNIRAC FLAT FLASHING,ECOFASTEN ECOFOOT5 0� ELECTRICk. NEC 2017 NOT TO SCALE w E FIRE: MASSACHUSETTS COMPREHENSIVE FIRE T�001.00 MSP UPGRADE: NO S SAFETY CODE(527 CMR 1.00) A B C D E F G H (SHEET p A B C D E F G H 2.1.1 SITE NOTES: 4.5.1 GROUNDING NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, REGULATIONS. AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR I NSI�I ll o 1 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS SUCH USE. 17 1 A UTIUTY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MINIMUM NEC TABLE 250.122. MECHANICAL,OR BUILDING ROOF VENTS, 2.5.4 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 110.26. 690.45 AND MICROINVERTER MANUFACTORERS'INSTRUCTIONS. CONTRACTOR 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED,AND MAINTAINED IN 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF 2 INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT INSIGHT SOLAR BUILDING OR STRUCTURE. THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. PHONE 413'338'7555 2.2.1 EQUIPMENT LOCATIONS: 2.5.1 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH ADDRESS:180 PLEASANT ST,SURE 2 22.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING EASTHAMPTON,MA 01027 110.26. CONDUCTOR TO ANOTHER MODULE. 2.23 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR 2.5.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED.SHALL BE COLORED EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C) GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.1191 UC.NO.: MA 192102 AND NEC TABLES 310.15(B)(2XA)AND 310.15(BX3X% 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC HIC.NO.: 22.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR ELE.NO.: ACCORDING TO NEC 690.34. INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO GRAWWR SE!WUSE OF Tl#S3Eo THOUT us PROVIDED " S UN 2.2.5 ADDITIONAL AC DISCONNECTS)SHALL BE PROVIDED WHERE THE INVERTER NEC 250,NEC 690.47 AND AHJ. PERMSSJO FRaI CONI TMISM IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(8)(1)AND(2)TO NO WLL EP U.S.C TTOC Rr uws ARovnOaEBU.S.0 roGHT 3 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL REDUCE FIRE HAZARDS DAMAGES ND PROSECUTDIS. ACCORDING TO NEC APPLICABLE CODES. NEW PV SYSTEM:9.300 kW 227 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: P OUTDOOR USAGE WHEN APPROPRIATE. 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ����® IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO 2.3.1 STRUCTURAL NOTES: THE TERMINALS MARKED'UNE SIDE'(TYPICALLY THE UPPER TERMINALS). 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE RESIDENCE CODEA CODE-COMPLIANT INSTALLATION MANUAL TOP CLAMPS REQUIRE A LOCKABLE,AND BE A VISIBLE-BREAK SWITCH DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A 49 COLUMBUS AVE MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY, RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(0). NORTHAMPTON,MA 01060 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9. APN:NHAMM:038BB:0149L:0001 IF ROOF-PENETRATING TYPE.IT SHALL BE FLASHED&SEALED PER LOCAL AND 240. 4 REQUIREMENTS. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(8). ENGINEER OF RECORD SEALED WI APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION CONTRACTOR ACCORDING TO NEC 690.11 AND UL1699B. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.7.1 INTERCONNECTION NOTES: 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. (B)l 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY 2.4.1 WIRING&CONDUIT NOTES: NOT EXCEED 120%OF BUSBAR RATING[NEC 705.12(DX2X3)I. 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE PAPER SIE iv 1T on B) 5 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE 2.4.4 VOLTAGE DROP LIMITED TO 1.50/e. END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(BX2X3)I• NOTES 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WI SUITABLE RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF WIRING CLIPS. BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE DATE: 0723.2019 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS EXCLUDED ACCORDING TO NEC 705.12(BX2)(3)(C). DESIGN BY:V.D. PHASE A OR L1-BLACK 2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 PHASE B OR 1-2-RED,OR OTHER CONVENTION IF THREE PHASE (8X2)(1) CHECKED BY: M.M. PHASE C OR L3-BLUE,YELLOW,ORANGE",OR OTHER CONVENTION 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH NEUTRAL-WHITE OR GREY SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 REVISIONS 6 IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT TO BE MARKED ORANGE[NEC 110.151. FROM ADDITIONAL FASTENING[NEC 705.12(BX5)I. G-001,00 A B C D mE m F m G m H (SHEET 2) A B C D E F G H GENERAL NOTES ®' 1 I. FIELD VERIFY ALL MAY NOT BEONT I II SI' HT1 2. ITEMS BELOW MAY NOT BE ON THIS PAGE v.r - PROPERTY LINE III 9�. CONTRACTOR INSIGHTSOLAR T-0" PHONE: 413338-7555 ADDRESS:180 PLEASANT ST,SUITE 2 / EASTHAMPTON,MA01027 / UC.NO.: MA 192102 HIC.NO.: 0 i ELE,NO.: URAUTHOM>FO HIS USE OF T / \ DRAWING SET WITHOUT WRITTEN \ PERNSSSION FROM CONTRACTOR IS IN O Q / wOIM ON OF U.S.COPYRrAq LAWS 3 AND N1A BE SUBJECT TO awl % NLAGESANDPROSECUTIONS. / NEW PV SYSTEM:9.300 kWp AC LOAD CENTER /gyp SMART UTILITY METER R'VI"SVO AC DISCONNECT / / / METER RESIDENCE o / 49 COLUMBUS AVE NORTHAMPTON,MA 01060 ' APN:NHAMM:038BB:0149L:0001 n AREA OF WORK V: ENTRANCE ENGINEER OF RECORD 35-0"\ \ 29'-6" \ � � / 5 5 / PAPER SIZE:rex Tr om BI SITE PLAN \ / DATE: 07.23.2019 DESIGN BY:V.D. CHECKED BY: M.M. SITE PLAN N 8 0� REVISIONS W E ,aB`=,._D. o B 16 ® A-101.00 B A B C DE F G H IS—T3, A NN B NN C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS ��INSIC HP-I 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ARRAY 6-1.240 kW [z41(N)MODULES ARRAYS-3.410W TILT.i DEGREES ARRAY 7.0.620 kW (XI 11(N)MODUES FLAT ROOF [z2](N)MODULES TLT:45 DEGREES AZIMUTH:216 DEGREES TILT:45 DEGREES CONTRACTOR ROOF PITCH:1212ROOF PITCH:12:12 ARRAY4.1.55OkW AZIMUTH:II80�5 AZIMUTH:306 DEGREES O MODULE STRINGING 0A(N)MODULES INSIGHT SOLAR TILT 18 DEGREES 2ROOF PITCH:4:12 O MODULE STRINGING AZIMUTH:216 DEGREES PHONE: 413.338.7555 O O O ADDRESS:180 PLEASANT ST.SUITE M g EASTHAMPTON. A01027 OEXTERIOR PV EQUIPMENT O LIC.NO.: MA 192102 INl(1)AC LOAD CENTERO O ❑ ❑ HK;.NO. (N)(1)SMART UTILITY METER O ENE� (N)(1)AC DISCONNECT g uRAufHOPo2ED uSE a TMs (E)(1)METER DRAMNO SET WITHOUT WRITTEN O O PERMS510N FROM CONTRACTOR SIN INTERIOR PV EQUIPMENT O NNILAT MOF u.S.00PYW.TUM (E)(1)MAIN ELECTRICAL PANEL B OA OA AHOMu A su ROSECUONS 3 O O O O ouAu,ESN10Ha>sEcullorEA. O NEW PV SYSTEM:9.300 kWp O O RUSSO ARRAY kW O O [X21(N)MODULES TILT:OOFPI CH 4:12 O O O RESIDENCE ROOF PITCH:EES rzx ADMUTH�.306 DEGREES 49 COLUMBUS AVE NORTHAMPTON,MA 01060 ARMY 2-0.620 kW (x2](N)MODULES API:NHAMM:03866:0149L:0001 4 TILT:18 DEGREES ROOF PITCH:4:12 O O AZIMUTH:126 DEGREES ENGINEER OF RECORD ARMY 8-0.620 kW [X21(N)MODULES TILT:30 DEGREES ARMY 3-0.620 kW ROOF PITCH:7:12 [,A(N)MODULES AZIMUTH:126 DEGREES TILT:45 DEGREES ROOF PITCH:1212 AZIMUTH:306 DEGREES PIPER SIZE I1*,.r(ANIN B) 5 ELECTRICAL PLAN 39.37" DATE: 07.23.2019 I` DESIGN BY:V.D. MODULE: CHECKED BY: M.M. ELECTRICAL PLAN65.75" CERTAINTEED SOLAR REVISIONS CT31OM10-03 6 01 18=1 0® f 310 WATTS L A-102.00 A B C D E NNF NNG NNH 1SIEET 4) A B C D E F G H GENERAL NOTES P 1 1. FIELD VERIFY ALL MEASUREMENTS INSIGHT5, 2. ITEMS BELOW MAY NOT BE ON THIS PAGE RAFTERS CONTRACTOR FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE(SEE SHEET 5.501 FOR MOUNTING DETAILS) INSIGHT SOLAR 2 �–––�––– PHONE: 413-338-7555 ROOF MATERIAL IS ROLLED ASPHA.T ADDRESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA 01027 --–––––O —�--� LIC.NO.: MA 192102 _,_______� ❑ ❑ Hie.NO.: ---- ELE.NO.: ----- — ---�--—-— I 1 I UNAUIHORI2ED VSE OF THIS I 1 1 I DRAWING SET WIIIf011T WRITTEN --——————?— PERWSSION FROM CONTRACTOR IS IN - + 00 A710N OF U.S.COPYRIGHT LAWS _———___:—�———— ————— I I I I I AND WILL BE SUBJECT TO CML 3 I 1 I I 1 OnwGEs AND PROSECUTIONS. 9 � — 1 1 I I I ----•----- NEW PV SYSTEM:9.300 kWp --------- ----b--- -- I I I I I I I - ___------ 1 �- RUSSO I I I I,_ I d '� ' RESIDENCE — I I I I I —_ 1 I I 1 I I I I I I I f YI —®— ❑ 1 d 01 I I I I I 49 COLUMBUS AVE F ' i NORTHAMPTON,MA 01060 I 1 I APN:NHAMM:038BB:0149L:0001 1 I 1 I 4 I I 1 I 1 I ENGINEER OF RECORD I I I I I I I I I BALLASTED SOLAR MODULES ATTACHED ROOF MATERIAL IS ASPHALT SHINGLE TO ROOF SURFACE(SEE SHEET S-502 FOR MOUNTING DETAILS) 5 PAPER SIZE.I I'I IT(ANSI B) SOLAR ATTACHMENT PLAN 39.37" DATE: 01.23.2019 T -� DESIGN BY:V.D. T MODULE: CHECKEDBY: M.M. 5 01 SOLAR ATTACHMENT PLAN 65.175' CT3 OMII10-03D SOLAR REVISIONS vB'=r 9® s F 1 310 WATTS _L_. A-103.00 A 8 C D E F G H (SHEET s) A B C D E F G H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS D TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP.CORR.FACTOR CONDUIT FILL FACTOR CONT.CURRENT MAX.CURRENT(125%) BASE AMP. D.-RATED AMP. TERM.TEMP.RATING AMP. TERMINAL I IVSIGHT I 1 1 10 AWG THWN-2.COPPER 0.75°DIA EMT 4 20A 8 AWG THWN-2,COPPER 0.1111(32.7- 6(54.7°C) 0.8 i6A 20A 40A 24.32A 75°C 35A 1 8 AWG THWW2,COPPER 0.75"DIA EMT 2 WA 8 AWG THWN-2,COPPER 0.9 (32.7°C) 1 30A 37.5A 55A 52.8A 75°C 50A 1 8 AWG THWN-2,COPPER 0.75"DIA EMI 2 40A 8 AWG THWN-2,COPPER 0.96(32.7°C) 1 "sl1A 37.5A 55A 52.8A 75'C SOA 1 6 AWG THWN-2,COPPER 0.75'DIA EMT 2 N/A 6 AWG THWN-2,COPPER 0.96(32.7°C) 1 30A 37.SA 75A 72A 75°C 65A PV SYSTEM EQUIPPED WITH RAPID CONTRACTOR A MODULE STRINGING SHUTDOWN DISCONNECT PER NEC 690.12 INSIGHT SOLAR 2 SYSTEM COMPLIANT WITH NEC 690.17 B MODULE STRINGING PHONE: 413338.7555 TO UTILITY ADDRESS:180 PLEASANT ST,SUITE 2 ENPHASEENVOY MAX.CONTINUOUS CURRENT:48A GRID(OH) EASTHAMPTON.MA 01021 COMMUNICATIONS MAX.OCPD:60A A LIC.NO.: MA 192102 GATEWAY 60A LOAD CENTERL HIC.NO.: 120/240V,10,3W NAUTHO: L1 ELF.N.:WED USE aTHIS (E)12OV N I DRAWING SET MTHOUT WRTTEN 11 GEWSSI N FROM C��TM IS WS OUTLET MI)VALLBESusJECTTO ftu 3 DMACES AM PRMCUTIMS MAIN ELECTRICAL PANEL NEW PV SYSTEM:9.300 kWp 5A 240/120 V 10,3W JUNCTION BOX C=) MAIN MAIN BUSS:100 A (E) 1< SS a CERTAINTEED SOLAR ENPHASE UTILITY METER RESIDENCE CT310M10 03 IQ7-60 2-US 49 COLUMBUS AVE GROUND NORTHAMPTON,MA 01060 ROD APN:NHAMM:038BB:0149L:0001 4I' A UTILITY REVENUE AC DISCONNECT,60A RED 20A MA SMART METER FUSE 40A,TYPE R ' (E)GROUNDING ENGINEER OF RECORD 14 � �,« � N � '` ELECTRODE IN BRANCH Ll c= TOP LUGS (E)MAIN L2 100A - --- -- 01 RED 20A 02 09 © 04 N TO(E) rr LOADS 16 SUCK IN BRANCH s PAPERM E I i,T,ANSI81 - - LINE DIAGRAM DATE: 07.232019 DESIGN BY:V.D. BOTTOM LUGS CHECKED BY: M.M. EQUIPMENT LEFT EQUIPMENT RIGHT 6 LINE IS(N)NEW LINE IS(E)EXISTING RENSIoNS UNLESS OTHERK/ISE NOTEDE-601.00 A m B aC mD E F G H M ER 6, A B C D E F G H SYSTEM SUMMARY MODULESINSIGHTS 1 BRANCH 01 BRANCH 02 REF. DTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP EMP.COEFF,OF VOC FUSE RATING 1 INVERTERS PER BRANCH 14 1 16 PMi-30 30 CERTAWTEED SOLAR CT31OM10-03 I 31OW 1287.06WI 9.8A I 9.3A I 41.1V I 33.3V I .0.115VPC(-0.28%PC) I 20A MAA AC CURRENT 14A II6A MAX AC OUTPUT POWER 3,SOOW1 4000W INVERTERS ARRAY STC POWER 9 30O OCPD MAXOUTPUTMAX INPUT CEC WEIGHTED REF.DTV. MAKE AND MODEL AC VOLTAG GROUND ��� RATED POWER CURRENT CURRENT INPUT VOLT EFFICIENCY ARRAY PTC POWER 8,612W MAX AC CURRENT 30A 11-30130 1 ENPHASE 10740.2-US I 240V FLOATING 20A 1 24OW 1A 15A 40V 97.0% CONTRACTOR MAX AC POWER 7,500W DERATED(CEC)AC POWER 7500W DISCONNECTS OCPDS REF.CITY. MAKE AND MODEL 1 RATEDCURRENT MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE INSIGHT SOLAR 2 DESIGN TEMPERATURES sw1 1 EATON DG222NRB OR EOUN. 60A 24ovAc CB1-2 2 20A 240VAC ASHRAE EXTREME LOW -25.rC(44.6-F),SOURCE:BARNES MUNI(42.18':-72.72') C83 1 5A 240VAC PHONE: 413.338.7555 ASHRAE 2%HIGH 327-C(90.91F),SOURCES BARNES MUNI(42.16';-7272') Fi-2 2 40A 240VAC ADDRESS:180 PLEASANT ST.SUITE 2 EASTHAMPTON,MA 01027 LICAO.: MA 192102 BILL OF MATERIALS HIC.NO.: CATEGORY MAKE MODELNUMBER REF QTYI UNIT QTYAINIT DESCRIPTION ELE NO.: MODULE CERTAWTEED SOLAR CT310MIO-03 PM170 30 1 PIECES 1 CERTAINTEED SOLAR CT31OM10-0331OW 60 CELLS,MONOCRYSTALLINE SILICON UNAUTHORZEDUSEOFTHIS INVERTER ENPHASE 107-W2-US 11-30 30 1 PIECES 1 ENPHASEIQ7-BO-2-US 240W INVERTER DMWING SET WTHOUT MITTEN DISCONNECT EATON DG222NRB SW1 1 PIECE 1 EATON DG222NRB,2-POLE,60A,240VAC OR EQUIVALENT AOIPERMISSIONTION OFU S,OPMGHT AWR IS IN haunON OF Us.covtta CT uws PRODUCTION METER GENERIC MANUFACTURER GEN-METER-80A M1 1 PIECE 1 ELECTRICAL METER,OWNER APPROVED AND W L BE SU CT TO CMI DAMAGES AND PF09ECUipNS. 3 MISC ELECTRICAL EOIKPMENT GEN-CABLE-CLIP 150 PIECES 1 GENERIC CABLE CLIP AC COMBINER PANEL ENPHASEIQ-PANEL EPI 1 PIECE 1 ENPHASE IO COMBINER(X4Q-AMI-240.8) NEW PV SYSTEM:9.300 kWp MONITORING ENPHASE-ENVOY ENV1 1 PIECE 1 ENPHASE ENVOY WIRING ENPHASE 0.12.17-240 ENI-00 30 PIECES 1 ENPHASE ENGAGE(TM)TRUNK CABLE FOR 60 CELLS MODULE LANDSCAPE LAYOUT D C C O WIRING ENPHASE Q-TERWIO EN31 1 BUNDLE 10 ENPHASE ENGAGE(TM)BRANCH TERMINATOR R SS WIRING ENPHASE O SM-10 EN32 1 BUNDLE 10 ENPHASE ENGAGE(TM)WATERTIGHT SEALING CAP WIRING GEN-I0-AWG-THWN-2-CU-RD WR1 1 60 1 FEET 1 10 AWGTHWN-2,COPPER.RED(LINE 1) RESIDENCE WIRING GEN-I0-AWC-THWN-2-MBLK Will 60 FEET 1 10 AWG THWN-2,COPPER BLACK(LINE 2) WIRING GEN-8-AWG-THWN-2-CU-RD WR2-3 30 FEET 1 8AWGTHWN-2,COPPER,RED(LINE 1) 49 COLUMBUS AVE WIRING GEN$AWGTHWN-2-CU-BLK WR2-3 30 FEET 1 8AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-B-AWG-THWN-2-CU-WH WR2-3 30 FEET 1 8AWG THWN-2,COPPER,WHITE(NEUTRAL) NORTHAMPTON,MA 01060 WIRING GEN4AWG-THWN-2-CU-GR WRI-3 90 FEET 1 8AWG THWN-2,COPPER,GREEN(GROUND) APN:NHAMM:038BB:0149L:0001 WIRING GEN$AWG-THWN-2-CLLRD WR4 20 FEET 1 6 AWG THWN-2,COPPER,RED(UNE 1) 4 WIRING GEN4IAWG-THWN-2-CU4hX WR4 20 FEET 1 6 AWG THWW-,COPPER,BLACK(LINE 2) WIRING GEN-&AWG-THWN-2-CU-WH WR4 20 FEET 1 6AWG THWN!-2,COPPER.WHITE(NEUTRAL) ENGINEER OF RECORD WIRING GEN$AWG-THWN-2-CU-GR WR4 20 FEET 1 6 AWG THWN-2,COPPER,GREEN(GROUND) WIREWAY ENPHASE ETSPLK-05 I ENS I 7 IBUNDLE 5 ENPHASE ENGAGE(TM)ENGAGE COUPLER WIREWAY GEN-EMT-0.75-DN I WW14 1 80 1 FEET 1 EMT CONDUIT,0.75-DIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC 28I-2 2 PIECES 1 CIRCUIT BREAKER 20A,240VAC OCPD GENERIC MANUFACTURER GEN-CB-5A-24OVAC CB3 1 PIECE 1 CIRCUIT BREAKER 5A,24OVAC OCPD GENERIC MANUFACTURER GEN-FU4OA-24OVAC I FI-2 1 2 1 PIECES 1 FUSE,40A.240VAC TRANSNION BOX GENERIC MANUFACTURER GEN-AWB-TS44X I J81 I 1 I PIECE 1 TRANSITIONIPASS-THROUGH BOX,WITH 4 TERMINAL BLOCKS PAPER S0>E Tr.1r(NISI BI 5 DESIGN TABLES DATE: 07.23.2019 DESIGN BY:VD. CHECKED BY: M.M. REVISIONS 6 E-602.00 A B C D mE mF mG mH (SHEET rl A B C D E F G H 1 !CAUTION! 4INSIGHT POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CONTRACTOR FRONT PV ARRAY INSIGHT SOLAR 2 PV ARRAY PHONE: 413338.7555 ADDRESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA 01027 TURN RAPID SHUTDOWN rJ \, LIC.NO.: MA 192102 LABEL 3SWICH TO THE"OFF" - _I ELE NO. URAN AT EACH DISCONNECTING MEANS FOR POSITION TO SHUTDOWN MU OR PHOTOVOLTAIC EQUIPMENT THGSEUSE OF PV SYSTEM AND REDUCE M ORAIMNG SETT YATIOUi WIBTTEN [NEC 690.13 AND 690.15) SHOCK HAZARD IN ARRAY PERIASSION FROM CONTRACTOR IS IN ARRAY V OUTION OF Us.COPYMGHT(AVIS PV ARRAY AND M BE SUBJECT TOCwO 3 LABEL1 MAIN DISTRIBUTION DAIMGES AND PROSECUTIONS. AT RAPID SHUTDOWN SYSTEM DIRECTORY 'L BACK UTILI7Y DISCONNECT NEW PV SYSTEM:9.300 kWp [NEC 690.56(C)(1)(A)1 3 PERMANENT PLAQUE OR =lsp °CAUTION! NTERACTIVE PHOTOVOLTAIC SYSTEM DIRECTORY PROVIDING O RUSS® THE LOCATION OF THE O OO O CONNECTED O SERVICE PHOTOVOLTNCSYSTEM PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED DISCONNECTING MEANS RESIDENCE M CIRCUIT IS BACKFED NW SIDE OF THE HOUSE AND THE PHOTOVOLTAIC LABELIS LABEL 7 PLAQUE MEANS DISCONNECTING 49 COLUMBUS AVE MEANS IF NOT IN THE AT POINT OF INTERCONNECTION;LABEL,SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY SAME LOCATION NORTHAMPTON,MA 01060 PHOTOVOLTAIC SYSTEM [NEC 690.56(8)1 APN:NHAMM:038BB:0149L:0001 [NEC 705.12(8X4)] WHERE THE PV SYSTEMS 4 ARE REMOTELY LOCATED PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM FROM EACH OTHER,A O INTERACTIVE PHOTOVOLTAIC SYSTEM ° o AC DISCONNECT ° EQUIPPED .• DIRECTORY IN ENGINEER OF RECORD CONNECTED ACCORDANCE WITH 705.10 OPERATING CURRENT 30A AC SHUTDOWN SHALL BE PROVIDED AT oPERAnNG VOLTAGE. 240 V AC EACH PV SYSTEM LABEL 8 LABELS LABEL 10 DISCONNECTING MEANS. AT UTILITY METER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SWITCH PV SYSTEM EQUIPMENT [NEC 690.56(B)I AT DISCONNECTING MEANS (NEC 690.56(C)1. AND DISCONNECTING [NEC 690.541 LETTERS AT LEAST 3/8 INCH:WHITE ON RED MEANS SHALL NOT BE BACKGROUND;REFLECTIVE INSTALLED IN BATHROOMS IIFC 605.11.1.1 INEC 690.4(D),(E)l 5 O PHOTOVOLTAIC ° POWER SOURC PAPERWE"'.IrIANs B) POI,`iER SOURCE AC DISCONNECT PLACARDS LABEL 11 LABEL 12 LABEL 13 DATE: 07.231019 AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE [NEC 690.13(8)] OVERCURRENT DEVICE DESIGN BY:V.D. SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, LABELING NOTES [NEC 705.12(BX2)(3XB)1 OR FLOORS. 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605.11,OSHA CHECKED BY: M.M. (NEC 690.31(G)1 STANDARD 1910.145,ANSI Z535 LETTERS AT LEAST N8 INCH;WHITE ON RED BACKGROUND: 12 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. REVISIONS 6 REFLECTIVE 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. [IFC 605.11.1.11 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 318'AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED."DANGER"WILL HAVE RED BACKGROUND;"WARNING"WILL HAVE ORANGE E-603.00 BACKGROUND;"CAUTION'WILL HAVE YELLOW BACKGROUND.ANSI Z535 A B C D E F G H (SHEET B) E . G . H 27 _� GENERAL NOTES 5-50 1 111 46INSIGHTr, _ /-D6'%I T FIELOVERIFY ALMEASUREMENTS � 4 5 8 I 3 Q SHEET KEYNOTES 5 18 22 13 14 12 1. ROOF MATERIAL:ASPHALT SHINGLE CONTRACTOR Z RCAF STRUCTURE:KNEE WALL 23 24 25 �� 3. ATTACHMENT TYPE:UNIRAC FLAT FLASHING 4. MODULE MANUFACTURER:CERTAINTEED SOLAR INSIGHT SOLAR 2 5. M3DULE MODEL:CT31OM10-03 8. MODULE LENGTH:65.75 IN. MOD LE WIDTH:RACKING DETAIL LONGITUDINAL 8. MDDULE WEIGHT:39.37 1.9 LBS. PHONE: 180 PLEASANT DZ 9. SEE SHEET A-103FOR DIMENSION(S) ADDRESS:180 PLEASANT ST.SURE2 NOT TO SCALE 1 0. MN.FIRE OFFSET:NO FIRE CODE ENFORCED EASTHAMPTON,MA 01027 11. RAFTER SPACING:24 IN.O.C. 12. RAFTER SIZE:2X8"NOMINAL LIC.NO.: MA 192102 13. LAG BOLT DIAMETER:51161N. 14. LAG BOLT EMBEDMENT:41N. HIC.NO.: RACKING DETAIL TRANSVERSE SUNFRAME 15. TOTAL AREA: 59 ENAVH0F D1 RAIL 16. TOTAL AREA T467.38 114.09 FT. uNAUTNG SET IM EDE Ions 17. TOTAi WEIGHT 1146.09 LBS. DRAWING SET MTNouT W+unEN NOT TO SCALE 18. WEIGHT PER ATTACHMENT:19.43 LBS. PERMSSION FROLe CONTRACTOR IS IN to DISTRIBUTED LOAD:2.45 PSF AND MLL BE SUBJECT TO CNIL 3 20. MAX.HORIZONTAL STANDOFF:481N. DAMAGES AND PROSECUTIONS. 10 OSI 21. MAX.JERTICAL STANDOFF: LANDSCAPE 39 IN.PORTRAIT:66 IN. NEW PV SYSTEM:9.300 kWp 22. STANDOFF STAGGERING:NO 23. RAIL MANUFACTURER(OR EOUN.):UNIRAC R'ICO 25. RUL 10 MODEL E GHT:0 PEFUIVALENT):SUNFRAME RAIL uJ s ® 26. MODULE LE RAAC:3I RESIDENCE I 27. MODULE CLEARANCE:31N.MIN.,61N.MAX. L Fool 49 COLUMBUS AVE O 2+ NORTHAMPTON,MA 01060 ® APN:NHAMM:038BB:0149L:0001 4 J ENGINEER OF RECORD DETAIL (ISOMETRIC) D6NOT TO SCALE 0 RACKING DETAIL TOP D3NOTTOSCALE 5 ® PAPER BRE++•s+i'PaLBI BI 0 ASSEMBLY DETAILS AN DATE: 07.232019 KIKI DESIGN BY:V.D. CHECKED BY: M.M. DETAIL TRANSVERSE DETAIL LONGITUDINAL) REVISIONS D4NOT TG SCALE ®5 NOT TO SCALE S-501.00 A B C -16--- -p- -- - E - _- F - C H - (SHEET 9) _,e=z A g B C -_.g._.. .�___�_.....,._-�._.V. .._��._�-E F .--�--- G -—-— H Q SHEET KEYNOTES D4 D5 INSIGHT-1 1. ROOF MATERIAL ROLLED ASPHALT 50 '-- 2. ROOF STRUCTURE. KNEE WALL 18 15 7d 5 B 3. ATTACHMENT TYPE: BALLASTED 4. MODULE MANUFACTURER:CERTAINTEED SOLAR 03 5. MODULE MODEL.CT310M10-03 6. MODULE LENGTH:65.75 IN. 7. MODULEWDTH:39.37IN. t:' %~• %:+ ; '1 -•`+iv%%iii CONTRACTOR B. MODULE WEIGHT:41.7 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 2 10. MIN.FIRE OFFSET:NO FIRECODE ENFORCED - INSIGHT SOLAR 11. TOTAL#OF ATTACHMENTS:9 12. TOTAL AREA:71.9 SQ.FT. PHONE: 413338-7555 13. TOTAL WEIGHT:176.32 LBS. ADDRESS:180 PLEASANT ST,SUITE 2 14. WEIGHT PER ATTACHMENT:2.99 LBS. D1 RACKING DETAIL(TRANSVERSE) EASTHAMPTON,MA 01027 15. DISTRIBUTED LOAD:2.45 PSF. 16. STANDOFF STAGGERING:NO 5501 SCALE:NOT TO SCALE 17. RACKING MANUFACTURER(OR EQUIV.):ECOLIBRIUM UC.NO.: MA 192102 18. RACKING MODEL:ECOFOOTS 19. RACKING WEIGHT:TYPICAL 2.4.7.7 PSF HIC.NO.: 20. MAX.RAIL SPAN:481N. ELE N0-' 21. MAX.RAFTER SPAN:8 FT. UNAIJT a ZEOUSEOFTHIS ONA'A1NG SET NTHOUT MIMEN PERMISSION FROM CONWCTOR IS IN WIND DEFLECTOR �nLBE SUBJECT TO CN11 AWS 3 10AWES AND PROSECUTIms. ______ NEW PV SYSTEM:9.300 kWp RUSSO RESIDENCE D2 RACKING DETAIL (LONGITUDINAL) 49 COLUMBUS AVE S501 SCALE:NOT TO SCALE NORTHAMPTON,MA 01060 APN:NHAMM:038BB:0149L:0001 4 Q ENGINEER OF RECORD 10 } 0T � MODULE CLAMP 5 PAPERSIZE inlrIANSIBI ASSEMBLY DETAILS ©-� DATE: 07.232019 DESIGN BY:V.D. D3 RACKING DETAIL(TOP) D4 DETAIL(TRANSVERSE) F D5 I DETAIL (TRANSVERSE) CHECKED BY: M.M. 5-501 SCALE:NOT TO SCALE $-501 SCALE:NOT TO SCALE 5-501 SCALE:NOT TO SCALE REVISIONS 6 S-502.00 A B C D E F G H (SKET 10) A B ex C ex D se E se F G as H 1 4&INSIGHT • O Electrical Characteristics . 29SW 30OW 30SW 31OW Nominal Output(Pmpp) W 295 300 SOS 310 . • . fii Voltage at Pmax(Vmpp) V 32.1 32.5 32.9 33.3 CONTRACTOR Current at Pmex(ImPP) A 9.2 9.2 9.3 9.3 2 Open Circuit Voltage(Voc) V 39.9 40.3 40.7 41.1 INSIGHT SOLAR Short Circuit Current(19c) A 9.7 9.8 9.8 9.8 PHONE: 413.338-7555 Output Tolerance W -4.99/-0 ADDRESS:180 PLEASANT ST.SUITE 2 EASTHAMPTON,MA 01027 No.of Calls 8 Connections 60 at aeries with 3 bypeaadlodea } Maximum Series Fuse Rating 20A 20A 20A 20A UC.Na: Ma 192102 '., cell Type 6"Mon-lintaglna HIC.NO.: Module Efficiency % 17.7% 18.0% 18.3% 18.6% ELE NO.: UNAUTXOPoZEO USE OF THIS _ TimunwalWe Coefficient of Pmpp %/C •0:37 DRAmNGSEi m71OUTIVIVUEN y PERMSSIONFit0u CONTP 0RISIN Temperature Coefficient of Vac %/C -0.26 MDNL E URIECT TO ANO y4LL BE SUBJECT TO CNIL 3 �. �B Temperature Coefficient of ist, %/C CIO6 DNa1GESANDPROSECUTONS. NEW PV SYSTEM:9.300 kWp Mechanical Characteristics I Dimensions RUSSD ® Monocrystalline"Type Lamnteb ON-3.2 hightraUntni n, or,aNwx�a tempeRESIDENCE red, nti-refaactwe --i CT29SMXX-03 Ensapsulanb EVA slountin 1. Jurxllon Bw CT300MXX-03 BeckshaeC Weahwproor Olen �1 - ! 49 COLUMBUS AVE CT305MXX-03 (Black W Wil") CT310MXX-03 0 ta•Frame Anodized aluminum(Black) NORTHAMPTON,MA 01060 ilik U Power Output APN:NHAMM:038BB:0149L:0001 „c...daxxsN..t caor.„P.ai„b. Warranty Juncimn Box IP68.IEC testified.UL listed VowI ! I 4 ox wam. .tI S.-I-t... Output Cables 4 mmtraia '(12AWG)PV Wire, Mariark,Q'�1 tope„ Length 1.0m(39.4••) R>a ENGINEER OF RECORD •_ Features and Benefits ! "" Connecters Polarized MC4 compatible Ren 2 Weatherproof,IEC certified,UL lined SIDI 'Sal, 022 18.9 ht k (41.7 (l I•) High Quality/High Power �°'• Wei 9 9 lbs) I I I 11ann•I a Up 310W �w Operating Conditions a ULlistedto (UL1703) n a n I !it I R.tr a Output power tolerance+4.99/-OW ,... Nominal Operating Cell Tamp, 46•C+2 PID Fee Operating Temperature -40 to 85'C n.ar •Datrxe�'�•^^a•^I'n7 noua 5 Maximum System Voltage 1500v 4Gtar4lreha„ PAPER SIZE tt'.1r IAN51 S) Limited Warranty' Fire Performance Type 1 RESOURCE DOCUMENT is 10-year product warranty Maximum With Load 501bs/IN(2400 Pa) e 25-year linear power output warranty Maximum Snow Load 112 lbs/fN(5400 Pa) DATE: 07.23.2019 •sc- ccI„•ao.r:I.nnan..r.,.:n.Io.�u..n. DESIGN BY:V.D. D�m CertainTeed CartallfTeed Corporation CHECKED BY: M.M. �� SVNf-GOWN ClIL1a0a e[CItINe FtNte aYPeaM•IXae�ATIOM•aAlLtap Me e •TRIN SAINT-GOBAIN o 00<.Rwa .L.,.PA Iwss Prm„,. coo za weo c.....coo rare n for.L:.r.„..m RENSIONS 6 R-001.00 A all8 C ISD asE ISF asG ISH (SHEETII) A B sax C D as E aar F aaa G as H 1 4IRISIGH F; Enphase IQ 7 and IQ 7+Microinverters Enphase pAlcroinvertefs INPUT DATA(Dc) 1Q7.60-2-us 107.60-e_•_us 107PLUS-72-2-US y 107PLUS-72•e-US if f:if;� Commonly used module pairings' 235W-35OW+ 235W 440W. Module compatibility 60-cell PV modules only 60-cell and 72 Cell PV modules Maximum nlput OC voltage 48V 60V Peak power tracking voltage 27V-37V 27V-45V CONTRACTOR 0 rmige 16V 48V 16V-60V .. ....._ _.-._._ ....._._.._. _. _. Min/Max start voltage 22 V 148V 22 V 160V Max DC short circuit current(module Isc) 15A 15A INSIGHT SOLAR 2 The high-powered smart grid-ready Overvahage class DC Pan n N Enphase DCpa,tbackleedcunant 0A DA PHONE: 413-338-7555 Enphase IQ 7 Micro'"and Enphase IQ 7+Micro"' PV army configureti0n 1 x 1 ungrounded array,No additional DC side pmteCtmn regwfeQ Q 7 and I Q 7+ dramatically simplify the Installation process while AC side protection requires max 20A perbranchCircuit ADDRESS:180 PLEASANT ST,SUITE 2 OUTPUT DATA(AC) 10 7 Micruinverter IO 7.Nicrolnrertor EASTHAMPTON,MA 01027 achieving the highest system efficiency. Mi eroi nve rters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous ampul power 240 VA z90 vA Nominal O:L).11age/range• 240v/ 2.08V/ 240v/ 208V/ LIC.NO.: MA 192102 IQ 7+Microinverters integrate with the Enphase 211.264 V 183429 V 211-264 v 183-229v HIC.NO.: IQ Envoy",Enphase IQ Battery",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 v) 1.39A(208V) ELE.NO.: Nominal frequency 60 Hz 60 Hz uMurThCRZED USE a Tats Enlighten'"monitoring and analysis software. Extended frequency range 47.68Hz 47-68Hz DRAMNG SET MTHOUT MITTEN AC short Circuit fault current over 3 cycles 5.8 Arms 5.8 Arms PEWSBON FROM CONTRACTOR IS IN IQ Series Microinverters extend the reliability Maximum uill is per 20 A(L L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240VAC) it(208 VAC) NOTATION OF U.S.COPYNGHTIAM AND NIIL M SUBJECT TO CIVIL 3 standards set forth by previous generations and Overvoltage class AC pore Ill oil DAMAGES AND PROSECUTIONS. undergo over a million hours of power-on testing, Ac port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power tactor setting 1.0 1.0 NEW PV SYSTEM:9.300 kWp 9 P rY g Potver factor(adjustable) 0.85 leading...0.851aggmg 0-85 leading...0.85kggmg warranty of up to 25 years. EFFICIENCY @zoo v p2oe v �z4o v @zoo v RUSSO ---- --._. — W246V --20 — ----- — ------- -- I\ J Peak efficiency 97.5`.; 976: 97.5; 97.3 CEC weighted efAciemy 97.0"1, 97.0'v 97.0°b 97.0 a MECHANICAL DATA RESIDENCE __—._-_..___._____..__-._..-._—_____-- _—___ Ambient temPeratUrefen0e Relative humidity range 4:to 10M(condensing) 49 COLUMBUS AVE Easy to Install Connector type(IQ7.60-2-US8t07PLUS-72-ZUS)MC4 for AmphenolHit UTxwith additional QDCC-5adapter) Connector type(10760 B US 81Q7PLUS-72-B Us)Friends PV2(MC4 intent ateable) NORTHAMPTON MA 01060 •Lightweight and simple Adaptors for modules with MC4 at UTx connectors •Faster installation with improved,fighter two-wire cabling .Pv2 to MCA'.order ECA S20-S22 APN:NHAMM:03866:0149L:0001 -PV2 to UTx�order ECA.S20-S25 4 •Built-in rapid shutdown compliant(NEC 2014 8 2017) Dimensions(WxH%D) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2 3816.) Productive and Reliable Cooling Natural convection-No fans ENGINEER OF RECORD Approved(of vat locations Yes •Optimized for high powered 60-cell and 72-cell•modules Pollution degree PD3 •More than a million hours of testing Enclosure Class II double Insulated.corrosion reastam polymeric enclosure •Class II double-Insulated enclosure Enwronmem.1 category/UV exposure rating NENIA Type 6/outdoor •UL fisted FEATURES _.. Com cation Power Line L'omrnuntrauon(PLC1 Monitoring Enlighten Manager and MyEr lughten monnon°g oplionc Smart Grid Ready Both options reguare mstallalmn of an Enphase IQ Envoy Drsconnectiny means the AC and UC connectors have been eva.slad and approved by UL for use as the loa•b deak •Complies with advanced grid support,voltage and disconnect requiied by NEC 690. frequency ride through requirements Compliance CAR,*!21(UL 1741 SAI •Remotely updates to respond to Changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 CIaS.B,ICES-0003 Class S. pAPER8f2E It•x tl•(Algla) F CAN/CSAC222 N0.1071-01 grid requirements This product is UL Listed as PV Rapid Shut own Equipment and conforms with NEC-2014 and •Configurable for varying grtd profiles NEC-2017 section 690.12 and 0221 2015 Ruis 64.218 Rapid Shutdown of PV Systems,fa AC RESOURCE DOCUMENT •Meets CA Rule 21(UL 1141-SA) _ and DC conductors,when installed accoidin9martfacamer's Instructions. DATE: 07232019 uL •nie Iq 7.Mremmregw,en.o•.Fanta raven moow"' iNo vmav:uDant mno sec nmumiipaobnnYPaiwiaiw aimiparenpnasncona, u,upROTl7riwduliaotmaooi6ir z Non I 19P ai9 fie nU u 6 v w °iii i t I a fir are wnnr DESIGN BY:V.D. NINOl.ui I r yRl I R'm 11 ed I I icioni°ei ie.s Par ai.a Y°,r arra n ENP HAS E To learn more about Enphase offerings visit enphase.com E N PH AS E CHECKED BY: M.M. To learn more about Enphase offerings,visit enphase.com �•✓ ,I... 1 RENSIONS 6 R-002.00 A B C D asE F G asIS"EE,12) A B C D E F G H 1 INSIGHTO SUNFRAME : UNIRAC ' ► CONTRACTOR 2 SUNFRAME is a shared rail system with gap-free rows that boasts a sleek,low profile design.The refined INSIGHT SOLAR aesthetics are valued by discerning homeowners and architects for residential and light commercial 1 1 1 11 PHONE 413-338-7555 applications. Our system is compatible with many attachment options, including Unirac standoffs for ADDRESS:180 PLEASANT ST.SUITE 2 installation on comp shingle or the roofs.Modules are fully supported between shared rails,allowing for a EASTHAMPTON.MA 01027 streamlined install to achieve a seamless,refined look. LIC.NO.: MA 192102 HIC.NO.: ELE.NO.: 1 I I• UNAUTHORIZED USE OF THIS DRAWING SET N/1THOUT WRITTEN PERMS 90N FROIA CONMCTOR IS IN NOLATION OF U.S.COPYRIGHT l M ---.:: AND N BE SUWECT TO DNIL 3 D GESANDPROSECUTIONS. NEW PV SYSTEM:9.300 kWp RUSSO RESIDENCE 49 COLUMBUS AVE ' NORTHAMPTON,MA 01060 APN:NHAMM:038BB:0149L:0001 ENGINEER OF RECORD PAPER SIZE 11'•1T(ANSi 8) RESOURCE DOCUMENT SLEEK LOW PROFILE DESIGN DATE: 07.23.2019 REFINED DESIGN TOOLSDUALITY PROVIDERL ( L T i L DESIGN BY.'JA. CHECKED BY: M.M. REVISIONS 6 R-004.00 A B C D E F 3 H S-11< A B C D E F G H INSIGHTS CONTRACTOR 2 U n i ra c Flat Flashing INSIGHT SOLAR IN STA L LAT I O N MANUAL PHONE: 413.338.7555 ADDRESS:180 PLEASANT ST.SUITE 2 EASTHAMPTON.MA 01027 LIC.NO.: MA 192102 HIC.NO.: O 2011 by Unirac,Inc.All nghts reserved. ELE.NO.: Pub 110525-1ii,May 2011 Ut"HORZED USE OF THIS ORANING SET MTHOU t MnEH PERMSSON FROM CO TOR IS IN NOLATION OF U.S.COPYRIGHT LAWS AHO 1NLL BE SUBJECT TO CIVIL 3 wMAGESANOPRMCUTIMS. NEW PV SYSTEM:9.300 kWp RUSSO ► RESIDENCE 49 COLUMBUS AVE NORTHAMPTON,MA 01060 APN:NHAMM:038BB:0149L:0001 4 ,. - ENGINEER OF RECORD y: 8 *. . _` _ =' PAPER SIZE.n•,ItyAral e) Fm RESOURCE DOCUMENT DATE: 07.23.2019 ® DESIGN BY:V.D. •■ 1411 Broadway Boulevard NE ■■■ UNI RAC CHECKEDBY: M.M. ■■ Albuquerque, NM 87ioz-1545 USA REVISIGNS 6 R-005.00 A 8 C D E mF G H (SHEET 15) A B C D E F h INSIGHT iMax Out Your Roof CONTRACTOR 0 Fio 0 L5 2 INSIGHT SOLAR The New High 5 Simple Components.1 Sweet System. DensityMia-support PHONE: 413.338.1555 ADDRESS:180 PLEASANT ST,SUITE 1 i~ EASTHAMPTON,MA 01027 Small Footprint. Big Power. LIC NO.: MA 192102 _ / jJ= HIC.10. Ballast Tray . Pu��7L ULE No.: UNAUTHORIZAI DRAMNG SE M USE a nils Now you can build more PERMISSION tFROM COcONTRAACTOORIS IN NOTATION OF U.S.COPYRIGHT LAWS powerful rooftop solar ` Dtts�SU&IECT wTails 3 systems faster and easier than ever before with the new high density NEW PV SYSTEM:9.300 kWp Racking System. t RUSSO L' EcoFoot5D Base RESIDENCE 49 COLUMBUS AVE Preassembled Universal Clamp .' Wind NORTHAMPTON,MA 01060 Built on the Industry-Preferred EcoFoot*Platform,with More than 20OMW Installed. Deflector APN:NHAMM:038BB:0149L:0001 n Pailast;siacement that Beats All. Wire Management in a Snap. ENGINEER OF RECORD Accessible&Protected Ergonomic,Cost-Saving and Fast \ simply snap wire clips into Base to route wires between rows. Place ballasts between rows for easy reach. • No Uv exposure:row-lo-row wires covered by Ballast Tray No"iunder module access • Easy access to wires during install and throughout Rapid Ballast Tray install,sliding into Base retention clips 18.4%More Power Elegantly Simple Installation Cost-Saving Logistics&Support the life of the system with removable Wind Deflector Ballast Tray strong enough to walk on,even Small 7"x16.7"roof-friendly EcoFoot5D delivers preassembled Stackable bases enable a huge and in-row ballast placement when loaded with ballast blocks modular Base and dense 9.9" parts and an out-of-the-box,ready- per-pallet shipping capacity.Fewer - Mur mal roof contact means smaller slip inter-row spacing enables a to-go installation that Is unlike any pallets are required,minimizing _ ,� sheets,lowering costs tightly packed solar array that other Nat-roof racking.The result shipping,storage and onsite crane delivers 18.4%more power than is a seamless installation process use.Dedicated engineering support ' Qaa 5 10•systems.Whether your roof from start to Polish,saving on time prevents issues before they happen IL OWNDATE: PAPEASIZEIn.itIAx9Bl is small or large,EcoFoot5D and minimizingjob-site impact. and provides quick solutions ifprovidesmore power,lowering obstacles arise. RESOURCE DOCUMENT cost-per-watt. 07.23.2019 EcolibrillSola: / * DESIGN BY:V.D. x CHECKEDBY: M.M. Contact:740.249.1877 1 sales@ecolibriumsolarcom I wwwecolibrlumsolar.com 8 REVISIONS R-006.00 A B "- - D E F G 0H (SHED 16) Y A B C D E F G H GENERAL NOTES NEW PV SYSTEM: 9.300 kWp SHEET LIST TABLE t1.1 PROJECT rS TNIPJBER SHEET -001 OVERPA E '4 INSIGHT54 1 1.11 THS PHOTOVOLTAIC LPN SYSTEM SFIALL COMITY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE W0. ALL THE RELEVANT CO LISTING AND INSTALLATION INSTRUCTIONS,AND RU S S 0 RESIDENCE �1 ` THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAWING JURISDICTION'S(AHJ)APPLICABLE CODES. A-101 SITE PLAN 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV ROUND FAULSTEMT DETECTION PRIOR TOPARALLEL UPTIONOPERATION E 49 COLUMBUS AVE A-102 ELECTSOLAR ATTACCAL HMENT 1.1.4 GROUND FAULT DETECTION PND INTERRUPTION(GFDQ DEVICE IS CONTRACTOR INTEGRATED NTH THE MICROINVERTER IN ACCORDANCE WITH NEC h103 SOLAR ATTACI9AENT PLAN 690.41(B) E-601 LINE DIAGRAM INSIGHT SOLAR 2 1.1.5 ALL PJ SYSTEM COMPONENTS:MODULES.UTILITY-NTERAG„VE NORTHAMPTON, MA 01060 E-602 DESIGN TABLES =INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE PHONE: 413338-7555 IDENTIFIED AND LISTED FOR USE N PHOTOVOLTAIC SYSTEMS AS ASSESSOR'S#: NHAMM:038BB:0149L:0001 RED BY NEC 690.4: E'er PLACARDS ADDRESS:180 PLEASANT ST,SUITE 2 REOUIPV MODULES.UL1703.IE061730,AND IE061215,AND NEPA 70 CLASS C S-501 ASSEMBLY DETAILS EASTHAMPTON,MA 01027 FIRE INVERTERS:UL 1741 CERTIFIED,IEEE 1547.929.519 S-502 ASSEMBLY DETAILS COMBINER BOX(ES):UL 1753 OR UL 1741 ACCESSORY LN:.NO.: MA 191102 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED R-001 RESOURCE DOCUMENT K.NO.: TEMP COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE i1 R-002 RESOURCE DOCUMENT ELF NO.: CALCULATED ACCORDING TO NEC 690.7. UNAUTHOtlffD USE OF IRS R-003 RESOURCE DOCUMENT DRAINING.SET WRHOUI WRITTEN 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, PERUISRa+FROM CONTRACTOR IS IN AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A + .�„ YIOIATNIN a U.S.COPYRIGHT LAM PHOTOVOLTAIC POWER SYSTEM WILL RE IDENTIFIED AND LISTED R-004 RESOURCE DOCUMENT AND"LL eE SUBJECTTOCrvB 3 FOR THE APPLICATION PER 690A (D). SHALL BE INSTALLED R-005 RESOURCE DOCUMENT oAMACEs un lNmsECUTaxs. ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING '.T NEW PV SYSTEM:9.300 kW (NEC 1163 R-0O6 RESOURCE DOCUMENT I I P 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING '• F•t R V SSG. CODE IF EXPOSED TO SUPLIGHT,IT SHALL BE UV RESISTANT.ALL s PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE !+'! NEC AND MU. : ►f PROJECT INFORMATION RESIDENCE 1.2.1 SCOPE OF WORK: 11.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND - OWNER 49 COLUMBUS AVE SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM NAME: MARGRETRUSSO NORTHAMPTON,MA 01060 RETROFIT PRIME CONTRACTOR WILL BE RESPONSIBLE FOR AERIAL PHOTO COLLECTING EXISTING ONSITE REQUIREMENTS To DESIGN,SPECIFY. PROLPN:NHAMM:O38BB:O149L:0001 4 AND INSTALL THE EXTERIOR ROOFAKIUN7ED PORTION OF THE NAME TNANAGER PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 01 NOT TO SCALE NAME: ERIC WILSON PHONE: 413338-7555 ENGINEER OF RECORD 1.3.1 WORK10AIOES: 1.3.2 PV ROOF ATTACHMENTS-UNIRAC FLAT FLASHING,ECOFASTEN CONTRACTOR ECOFOOT5NAME: INSIGHT SOLAR 1.3.3 PV RACING SYSTEM INSTALLATION-UNIRAC SUNFRAME RAIL 4'py�SA`F PHONE: 413.338-7555 1.3.4 PV MODULE AND INVERTER INSTALLATION-CERTAINTEED SOLAR CT310MID-031 ENPHASE 107-%2-US ^ AUTHORITIES HAVING JURISDICTION 1.3.5 PV EQUIPMENT GROUNDING / \ BUILDING HAMPSHIRE COUNTY 1.3.6 PV SYSTEM WIRING TO A ROOF44OUNTED JUNCTION BOX / ZONING. HAMPSHIRE COUNTY 1.3.7 PV LOAD CENTERS OF INCLUDED) // `\ UTILITY: 1.3.8 W METERINGAAONTORING OF INCLUDED) \/ 3.9 PV DISCONNECTS DESIGN SPECIFICATIONS 5 1. / PAPER Siff.II'•IT(AN$I BI 1.3.10 PV GROUNDING ELECTRODE M BONDING TO(E)GEC / OCCUPAN'.I II 1.311 PV FINAL COMMISSIONING / / CONSTRLX'IGN. SINGLE-FAMILY COVER PAGE 1.3.12(EI ELECTRICAL EQUIPMENT RETROFIT FOR PV ` ZONINGRESIDENTIAL 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE GROUND%0W LOAD. 35 PSF SCOPE OF WORK \`� // tis WINDEXPOSLJRE B DATE: 07.231019 SYSTEM SIZE: STC:30 X 310W-9.3D0KW / WAND SPEFJ 120 MPH DESIGN BY:VD. PTC:30 X 287.06W-8.612KW DC (30)CERTAINTEEDSOLAR CT310M10-03 APPLICABLE CODES BSTANDARDS CHECKEDBY: M.M. (30)ENPHASE 107-60-2-US N BUILDING: MASSACHUSETTS RESIDENTIAL BUILDING REVISIONS PLATMAP CODE,9TH EDITION,AS AMENDED(780 CMR) 6 ATTACHMENT TYPE: UNIRAC FLAT FLASHING.ECOFASTEN ECOFOOT5 02 W[F E ELECTRICA- NEC 2017 MSP UPGRADE: NO FET NOT TO SCALE S FIRE: SE2 MASSACHUSETTS57 CMR i.00) SNE FIRE T-001.00 Am B C D E F G H (SHEET 1) A B C D E F G H 2.1.1 SITE NOTES: 4.5.1 GROUNDING NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, REGULATIONS. AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR �[ I NSIGHT 1 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS SUCH USE. IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MINIMUM NEC TABLE 250.122. MECHANICAL,OR BUILDING ROOF VENTS. 2.5.4 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISIING AND CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 110.26. 690.45 AND MICROINVERTER MANUFACTORERS'INSTRUCTIONS. CONTRACTOR 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF 2 INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT INSIGHT SOLAR BUILDING OR STRUCTURE. THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. PHONE: 413-338-7555 2.2.1 EQUIPMENT LOCATIONS: 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH ADDRESS:180 PLEASANT ST,SUITE 2 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING EASTHAMPTON.MA 01027 110.26. CONDUCTOR TO ANOTHER MODULE. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR 2.5.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C) GREEN OR MARKED GREEN IF$4 AWG OR LARGER[NEC 250.1191 UC.NO.: MA 192102 AND NEC TABLES 310.15(13)(2)(A)AND 310.15(B)(3)(C). 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC LSC.NO.: 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR ELENO" ACCORDING TO NEC 690.34. INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO UNAVANGSEEGUSEGFrNis CRANINGSEED UM OF Till N 2.2.5 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER NEC 250,NEC 690.47 AND AHJ. PERAAS.9GN FMA CONTRACTOR IS IN IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND(2)TO �MILLBE C P'OtlOCM 3 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL REDUCE FIRE HAZARDS OVMGES AM PROSECUIONS. ACCORDING TO NEC APPLICABLE CODES. NEW PV SYSTEM:9.300 KW 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: P OUTDOOR USAGE WHEN APPROPRIATE. 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH RUSS� IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO 2.3.1 STRUCTURAL NOTES: THE TERMINALS MARKED-LINE SIDE-(TYPICALLY THE UPPER TERMINALS). 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE RESIDENCE CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A LOCKABLE,AND BE A VISIBLE-BREAK SWITCH DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A 49 COLUMBUS AVE MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY, RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). NORTHAMPTON,MA 01060 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9. APN:NHAMM:038BB:0149L:0001 IF ROOF-PENETRATING TYPE.IT SHALL BE FLASHED&SEALED PER LOCAL AND 240. 4 REQUIREMENTS. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). ENGINEER OF RECORD SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION CONTRACTOR. ACCORDING TO NEC 690.11 AND UL1699B. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.7.1 INTERCONNECTION NOTES: 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. (B)] 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY 2.4.1 WIRING&CONDUIT NOTES: NOT EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE PAPER SIZE 1r.+r(ANSI 3) 5 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE 2.4.4 VOLTAGE DROP LIMITED TO 1.5%. END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(6)(2)(3)]. NOTES 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WI SUITABLE RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF WIRING CLIPS. BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE DATE: 07.232019 2.4.6 .AC CONDUCTORS COLORED OR MARKED AS FOLLOWS EXCLUDED ACCORDING TO NEC 705.12(13)(2)(3)(C). DESIGN BY:V.D. PHASE A OR L1-BLACK 2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE (13)(2)(1) CHECKED BY: M.M. PHASE C OR L3-BLUE,YELLOW,ORANGE OR OTHER CONVENTION 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH NEUTRAL-WHITE OR GREY SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 REVISIONS 6 IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT TO BE MARKED ORANGE[NEC 110.151. FROM ADDITIONAL FASTENING[NEC 705.12(13)(5)]. G-001.00 A B C D mE mF 3 H (SHEET n B C D E F G H GENERALNOTES _ 1. FIFIDVERIFYAUMEASUREMENTS ��INSIGHTS 1 2. ITEMS BELOW MAY NOT BE ON THIS PAGE `(/�. ------- PROPERTY LINE 9� CONTRACTOR 2 %_� INSIGHT SOLAR �`�\ 3' PHONE:PHONE: 413-338.7555 ADDRESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA 01027 , LIC.ND.: MA 192102 mc.NO ELF 0 i LE NO.: RAIuseof MISMISDRAWING / / \ DRAWWINGNG SET SEi WITHOUT WTUTTEN / \ PERN]SVIOLATIBION FROM CONTRACTORW IN Q / AND W1O BE UBJECT TO CIVIL 3 ANDNILL ANDM SECUTIWIL i uvAwes AND RRosEcuiloNs. / NEW PV SYSTEM:9.300 kWp AC LOAD CENTER SMART UTLITYMETER RUSSO AC DISO"ECT / METER / / o RESIDENCE 49 COLUMBUS AVE NORTHAMPTON,MA 01060 /ENTRANCE 4 AREA OF WORK APN:NHAMM:038BB:0149L:0001 � ENGINEER OF RECORD 35-0" \ 29'-6' 5 5 / wren SIM n•.Ir wel BI \ / SITE PLAN \ / DATE: 07.232019 DESIGN BY:V.D. CHECKEDBY: M.M. SITE PLAN N 8 REVISIONS W E ,,,5"=,._o. 0 81 16' ® A-101.00 g A B C D E F G H (SHEET 3, T A B C D E F G H GENERALNOTES 1 1. FIELD VERIFY ALL MEASUREMENTS '��NSIGH 6 T 2, ITEMS BELOW MAY NOT BE ON THIS PAGE ARRAY 6.1.240 kW [X41(N)MODULES ARRAY 5.3.410 kW TILT.1 DEGREES ARRAY 7-0.62D kW (x111(N)MODULES FLAT ROOF (u21(N)MODULES TILT:45 DEGREES AZIMUTH:216DEGREES TILT:45 DEGREES CONTRACTOR ROOF PITCH:12:12 ROOF PITCH:1212 ARRAY 4-1.550 kW AZIMUTH.216 DEGREES AZIMUTH:306 DEGREES O MODULE STRINGING Ix51(N)MODULES TILT 18 DEGREES INSIGHT SOLAR 2 ROOF PITCH:4:12 a MODULE STRINGING AZIMUTH:216 DEGREES -" PHONE: 413.338-7555 O O O ADDRESS:18DPLEASA14T ST.SUITE 2 EA B EASTHAMPTON.MA01027 OEXTERIOR w EQUIPMENT O UC.NO.: MA 192102 (N)(1)AC LOAD CENTER HIC.NO.: (N)(1)SMART UTILITY METER O O O ELE NO.: (N)(1)AC DISCONNECT B UNAUTHORIZED USE OF THIS (E)(1)METER DMMW SET WTHOUT WRITTEN O O PERMISSION FROIACONTRACTORISIN INTERIOR w EQUIPMENT O AOI TIMOR U.S.COPYRIGHT LAWS (E)(1)MAW ELECTRICAL PANEL B OA OA [MOGE RND PROCCUTiOW 3 O O O O DAMAGESAHD RROSELUTgN3, O NEW PV SYSTEM:9.300 kWp O O RUSSO ARRAY I-0.620 kWO O Ix21(N)MODULES )0- AWAY TILT18 FPITCH 4ES O O RESIDENCE ROOF PITCH:EES A ® ❑ AZIMUTH:306 DEGREES �010 o A 49 COLUMBUS AVE NORTHAMPTON,MA 01060 z-o jq(N)MODULES APN:NHAMM:038BB:0149L:0001 4 TILT:18 DEGREES ROOF PITCH:4:12 O L AZIMUTH:126 DEGREES ENGINEER OF RECORD ARRAY 8-0.620 kW Ix21(N)MODULES TILT:30 DEGREES ARRAY 3-0.620 kW ROOF PITCH:7:12 ISI INI MODULES AZIMUTH:126 DEGREES TILT:45 DEGREES ROOF PITCH:1212 AZIMUTH:306 DEGREES PAPERSIZE 11'x Ir(ANSI e) 5 ELECTRICAL PLAN 39.37" DATE: 07.23.2019 �I DESIGN BY:V 0. 01 ODULE: CHECKEDB Y: M.M. CMSOLAR REVISIONS a ELECTRICAL PLAN CT31OM10-03 LJo® m L 310 WATTS A-102,00 A B C D E F G H (SHEET o A B C D E F G H GENERAL NOTES _ 1. FIELD VERIFY ALL MEASUREMENTS INSIGHTS 1. ITEMS BELOW MAY NOT BE ON THIS PAGE RAFTERS CONTRACTOR FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE(SEE SHEET 5.501 FOR MOUNTING DETAILS) INSIGHT SOLAR 2 -c---s--- PHONE: 41133&7555 ----b---< ROOF MATERIAL IS ROLLED ASPHALT ADDRESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA 01027 -----e LIC.NO.: MA 192102 P---- �'-------4 71r-, HIC.NO.: ELE.NO.: ----- ----s----- I I I UNAUTHORIZED USE OF T IS DRAWING SET WITHOUT WRITTEN PEIWSSION FROM CONTRACTOR IS RI 0----- - VIOLATION OF U.S.COPYRIGHT LAWS MD WILL K SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM:9.300 kWp --------- -a--- ---.- I I RUSSO Y ❑ RESIDENCE I L I I I � a l i i OI ' I I I 49 COLUMBUS AVE NORTHAMPTON,MA 01060 1 , , APN:NHAMM:038BB:0149L:0001 I I I I 4 I L I i I ENGINEER OF RECORD _ I I I I I BALLASTED SOLAR MODULES ATTACHED ROOF MATERIAL IS ASPHALT SHINGLE TO ROOF SURFACE(SEE SHEET 5-502 FOR MOUNTING DETAILS) 5 PAPER SLZE+r,Hr(ANSI a) SOLAR ATTACHMENT PLAN 39,37' DATE: 07.23.2019 --� DESIGN BY:V.D. MODULE: CHECKED BY: M.M. SOLAR ATTACHMENT PLAN CREVISIONB B CT31OM10-03 TEEDSOLAR 01 65.15" 310M1 „B. s 1 310 WATTS A-103,00 A B C D E IIIF mJ—. G H (SHEETS) A B C D E F G H CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS CURRENT-CARRYING CONDUCTORS D TYPICAL CONDUCTOR CONDUIT IN CONDUIT OCPD EGC TEMP.CORR.FACTOR CONDUIT FILL FACTOR CONT.CURRENT MAX.CURRENT(125%) BASEAMP. DERATEDAMP. TERM.TEMP.RATING AMP. TERMINAL INSIGHTS 1 1 10 AWG THWN-2.COPPER 0.75'DIA EMT 4 20A 8 AWG THWN-2,COPPER 0.76(54.7°C) 0.8 16A 20A 40A 24.32A 75°C 35A 1 8 AWG THWN-2,COPPER 0.75"DIA EMT 2 NIA 8 AWG THWN-2,COPPER 0.96(32.7"C) 1 30A 37.5A 55A 52.8A 75°C 50A 1 8 AWG THWN-2,CUYPER 0.75'DIA EMI 2 40A 8 AWG THWN-2,COPPER 0.96(32.7`C) 1 3UA 32.5A 65A 52.OA 75'C 50A 1 6 AWG THWN-2,COPPER 0.75'DIA EMT 2 NIA 6 AWG THAN-2,COPPER 0.96(32.7°C) 1 30A 37.5A 75A 72A 75°C 65A PV SYSTEM EQUIPPED WITH RAPID CONTRACTOR A MODULE STRINGING SHUTDOWN DISCONNECT PER NEC 690.12 INSIGHT SOLAR 2 SYSTEM COMPLIANT WITH NEC 690.17 B 1 MODULE STRINGING PHONE: 413.33&1555 TO UTILITY ADDRESS:180 PLEASANT ST,SUITE 2 ENPHASE ENVOY MAX.CONTINUOUS CURRENT:48A GRID(OH) EASTHAMProN.Maolov COMMUNICATIONS MAX.OCPD:60A UC.NO.: MA 192102 GATEWAY 60A LOAD CENTER HIE.NO.: 120/240V,10,3WLL1 UNAUNO.: UNW HO WSETPEWSSCIIFD TROUT TWS Ef 120V N DRAW NO SET W A C(A WPo EN TOR (E) � NOIAnM OFF US CMT�TAt,IN OUTLET I MAD WLR aE SUBJECT TO CNB 3 � DARa ES AND PROBECUTMS. MAIN ELECTRICAL PANEL i NEW PV SYSTEM:9.300 kWp 5A 240/120 V 10,3W MAIN BUSS:100 (E)UTILITY RUSS� JUNCTION BOX CERTAINTEED SOLAR ENPHASE METER RESIDENCE CT31OM10-03 1Q7-60-2-US 49 COLUMBUS AVE GROUND NORTHAMPTON,MA 01060 ROD APN:NHAMM:038BB:0149L:0001 4 01 LL RED UTILITY REVENUE AC DISCONNECT,60A - (E)GROUNDING ENGINEER OF RECORD 14 Buu 20A MA SMART METER FUSE 40A,TYPE R N ELECTRODE IN BRANCH L1 ® TOP LUGS (E)MAIN 01 Lz 100 A 9/} ---- ---� N 20A o2 os � oa TO(E) RED LOADS 16 LL 81 IN BRANCH RARER BU,v.,T•(MSI 8) 5 _ LINE DIAGRAM DATE: 07.23.2019 DESIGN BY:V.D. BOTTOM LUGS CHECKED BY: M.M. EQUIPMENT LEFT EQUIPMENT RIGHT LINEIS(N)NEW LINE IS(E)EXISTING REVISIONS 6 UNLESS OTHERWISE C NOTED. Em601.00 A B C D mE F mG H ;B EE76, A B C D E F G H SYSTEM SUMMARY MODULES ";&INSIGHTS 1 BRANCH#1 BRANCH R2 REF. QTY. MAKE AND MODEL PMAX PTC LSC IMP VOC VMP "EMP.COEFF.OF VOC FUSE RATING INVERTERS PER BRANCH 14 1 16 PM7-30 30 CERTAINTEED SOLAR CT310MIO-03 I 31DW 1287.06WI 9AA I 9.3A 41.1V I 33.3V .0.115VPC(-D28%PC) 20A MAX AC CURRENT 14A 16A MAX AC OUTPUT POWER 3,50OW 4,000W INVERTERS ARRAY STC POWER 9,300W OCPD MAX OUTPUT MAX INPUT CEC WEIGHTED ARRAY PTC POWER 8,812W NEF..LTY.1 MAKE AND MODEL AC VOLTAGE GROUND RATING RATEDPOWER CURRENTCURRENTINPUT VOLTA EFFICIENCY MAX AC CURRENT 30A 30 ENPHASE 10780-2-US 240V FLOATING 20A I 24OW I 1A I 1.5A I 48V CONTRACTOR MAX AC POWER T—W DERATED(CEC)AC POWER 7,500W DISCONNECTS OCPDS REF.Ott. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. OTY, RATED CURRENT MAX VOLTAGE INSIGHT SOLAR 2 DESIGN TEMPERATURES SW1 1 EATON DG222NRB OR EOUN. 60A 240VAC CB1-1 2 20A 240VAC ASHRAE EXTREME LOW -25.9'C(-14.6'F),SOURCE:BARNES MUNI(42.16'.-72.72') CB3 1 5A 240VAC PHONE: 413.W7555 ASHRAE 2%HIGH 32.7"C(90.9"F),SOURCEBARNES MUNI j4216-:-72.72') Ft-2 2 40A 240VAC ADDRESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA01027 LJC-NO.: MA 192102 BILL OF MATERIALS IBC.NO.: CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION FIE.NO.: MODULE CERTAINTEED SOLAR CT31OM10-03 PM140 30 PIECES 1 CERTAINTEED SOLAR CT31OM10-0331OW 60 CELLS,MONOCRYSTALLINE SILICON UNAUTHOFe2ED USE OF cors INVERTER ENPHASE 10780-2-US 11.30 30 PIECES 1 ENPHASE IQ780-2-US 240W INVERTER DRAWINGSET MTHOUTN1UTTEN DISCONNECT EATON OG222NRB SWI 1 PIECE 1 EATON DG222NRB,2-POLE,60A,240VAC OR EQUIVALENT PERMSEION FROM CONTRACTOR ISN WOunoN OF U.S.COPrRIGHT LAWS PRODUCTION METER GENERIC MANUFACTURER GEN-METER-80A M1 1 PIECE 1 ELECTRICAL METER,OWNER APPROVED AND MEL BE SUVECT TO GIVE 3DAMAGES AND PROSECUT&A. MISC ELECTRICAL EQUIPMENT GEN-CABLE-CLIP 150 PIECES 1 GENERIC CABLE CLIP AC COMBINER PANEL ENPHASE4Q-PANEL EP7 1 PIECE 1 ENPHASE IQ COMBINER(X-IQ-AMI-240A) NEW PV SYSTEM:9.300 kWp MONITORING ENPHASE-ENVOY ENV1 1 PIECE 1 ENPHASE ENVOY WIRING ENPHASE Q-12-17-240 ENI-30 30 1 PIECES 1 ENPHASE ENGAGE(TM)TRUNK CABLE FOR 60CELLS MODULE LANDSCAPELAYOUT SS� WIRING ENPHASE Q-TERMRU -10 EN31 1 BUNDLE 10 ENPHASE ENGAGE(TM)BRANCH TERMINATOR SS WIRING ENPHASE 0SEAL-10 EN32 1 BUNDLE 10 ENPHASE ENGAGE(TM)WATERTIGHT SEALING CAP WIRING GEN-I0-AWG-THWN-2-CU-RD WR1 60 FEET 1 10 AWGTHWN-2,COPPER,RED(LINE 1) RESIDENCE WIRING GE4-10JAWG-THWF42CU-BLK WR1 60 FEET 1 10 AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-8-AWG-THWN-2CU-RD WR2-3 30 FEET 1 8AWGTHWN-2,COPPER,RED(LINE 1) 49 COLUMBUS AVE WIRING GEN41AWG-THWN-2-CUSLK WR2-3 30 FEET 1 8AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-MWG-THWN-2-CU-WH WR2-3 30 FEET 1 8AWGTHWN-2,COPPER,WHITE(NEUTRAL) NORTHAMPTON,MA 01060 WIRING GEN8-AWG-THWN-2CU-GR WR1-3 90 FEET 1 8 AWG THWN-2,COPPER,GREEN(GROUND) APN:NHAMM:038BB:0149L:0001 WIRING GEN."WG•THWN-2CLI-RD WR4 20 FEET 1 6 AWG THWN-2,COPPER,RED(LINE 1) 4 WIRING GENB,AWG-THWN-2CUSLK WR4 20 FEET 1 6 AWG THWN-2,COPPER,BLACK(LINE 2) WIRING GEN-6-AWG-THWN-2CLLWH WR4 20 FEET 1 6 AWG THWN-2,COPPER,WHITE(NEUTRAL) ENGINEER OF RECORD WIRING GEN-"WG-THWN-2-CU-GR WR4 20 FEET 1 6 AWG THWN-2,COPPER,GREEN(GROUND) WIREWAY ENPHASE ETSPLK-05 ENS _L BUNDLE 5 ENPHASE ENGAGE(TM)ENGAGE COUPLER WIREWAY GENEMT-0.75'DIA WW14 80 FEET 1 EMT CONDUIT,0.75"CIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CB1-2 2 PIECES 1 CIRCUIT BREAKER,20A,240VAC OCPD GENERIC MANUFACTURER GENC8-5A-240VAC C83 _L PIECE 1 CIRCUIT BREAKER,5A,240VAC OCPD GENERIC MANUFACTURER GEN-FU-40A-240VAC F1-2 2 PIECES 1 FUSE,40A,240VAC TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-44X JB1 1 PIECE 1 TRANSITIOWPASSTHROUGH BOX.WITH 4 TERMINAL BLOCKS 5 WAFER saE 1r,lrluaiel DESIGN TABLES DATE: 07.231019 DESIGN BY:V.D. CHECKED BY: M.M. REVISIONS 6 E-602.00 A B C D E F G mH (SHEET p A 8 C D E F G H !CAUTION! ° 16INSIGHTu POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CONTRACTOR FRONT PV ARRAY INSIGHT SOLAR 2 PV ARRAY PHONE: 413338-7555 ADORESS:180 PLEASANT ST,SUITE 2 EASTHAMPTON,MA 01027 TURN RAPID SHUTDOWN LIC.NO.: MA 192102 LABEL 3 SWICH TO THE'OFF' K.NO. AT EACH DISCONNECTING MEANS FOR POSITION TO SHUTDOWN E�'�" PHOTOVOLTAIC EQUIPMENT PV SYSTEM AND REDUCE [NEC 690.13 AND 690.151 u SHOCK HAZARD IN ARRAY PERIASSION FROM CONTRACTOR IS IN 'V ARRAY 'AOUPON OF u 5.COPYRIGHT IAWS 3 LABEL 1 PV ARRAY AND AlLL BE SUBJECT TO CIVIL MAIN DISTRIBUTION DAMA ES@ PROSECUTIONS. AT RAPID SHUTDOWN SYSTEM DIRECTORY Z BACK UTILITY DISCONNECT NEW PV SYSTEM:9.300 kWp [NEC 690.56(CX1)(A)1 PERMANENT PLAQUE OR ; ^ ^C�q DIRECTORY PROVIDING ° ° RUSSO !CAUTION! INTERACTIVE PHOTOVOLTAIC SYSTEM THE LOCATION OF THE V O O O CONNECTED O SERVICE PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED DISCONNECTING MEANS RESIDENCE CIRCUIT IS BACKFED NW SIDE OF THE HOUSE AND THE PHOTOVOLTAIC LABEL 6 LABEL 7 PLAQUE SYSTEM DISCONNECTING 49 COLUMBUS AVE MEANS IF NOT IN THE AT POINT OF INTERCONNECTION;LABEL,SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY SAME LOCATION NORTHAMPTON,MA 01060 PHOTOVOLTAIC SYSTEM [NEC 690.WB)1 APN:NHAMM:038BB:0149L:0001 [NEC 705.12(BX4)] WHERE THE FV SYSTEMS 4 PHOTOVOLTAIC FROM EACH OTHEREMOTELY R ASD O INTERACTIVE PHOTOVOLTAIC SYSTEM ° ° AC DISCONNECT ° EQUIPPED . 6 DIRECTORY IN ENGINEER OF RECORD CONNECTED ACCORDANCE WITH 705.10 OPERATING CURRENT :NIA AC SHUTDOWN SHALL BE PROVIDED AT OPERATING VOLTAGE. 240 V AC EACH PV SYSTEM LABEL 6 LABELS LABEL 10 DISCONNECTING MEANS. AT UTILITY METER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SWITCH PV SYSTEM EQUIPMENT [NEC 690.56(8)[ AT DISCONNECTING MEANS [NEC 690.56(C)l AND DISCONNECTING (NEC 690.561 LETTERS AT LEAST 318 INCH:WHITE ON RED MEANS SHALL NOT BE BACKGROUND;REFLECTIVE INSTALLED IN BATHROOMS IFC 605.11.1.1 [NEC 690.4(D),(E)I 5 ° PHOTOVOLTAIC ° PAPERS I1•.IT•INJSI8, AC DISCONNECT PLACARDS LABEL 11 LABEL 12 LABEL 13 DATE: 07232019 AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE (NEC 690.13(8)1 OVERCURRENT DEVICE DESIGN BY;V.D. SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, LABELING NOTES (NEC 705.12(BX2X3XB)I OR FLOORS. 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 606.11.OSHA CHECKED BY: M.M. [NEC 690.31(G)I STANDARD 1910.145,ANSI Z535 LETTERS AT LEAST 318 INCH;WHITE ON RED BACKGROUND; 12 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. REVISIONS 6 REFLECTIVE 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. [IFC 605.11.1.11 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8'AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED."DANGER'WILL HAVE RED BACKGROUND;'YARNING'WILL HAVE ORANGE E-603.00 BACKGROUND;'CAUTION'WILL HAVE YELLOW BACKGROUND.ANSI Z535 A B C D E F G H (SHEET BI _A ss: _ _._ B - _- tet_ ��_ E -----F G _ H 1 27 _ ®_ _ GENERAL NOTES so �� 1. HELD VERIFY ALL MEASUREMENTS (II&INSIGHT; 4 5 8 I' 3 I I Q SHEET KEYNOTES tt T,i 15 18 22 13 1/ 12 1. ROOF MATERIAL:ASPHALT SHINGLE CONTRACTOR -72 PoOOF STRUCTURE:KNEE WALL 23 24 25 2 3. ATACHMENT TYPE:UNIRAC FLAT FLASHING 4. MODULE MANUFACTURER:CERTAINTEED SOLAR INSIGHT SOLAR 2 5. MODULE MODEL:CT310MIO-03 6. MODULE LENGTH:65.15 IN. RACKING DETAIL LONGITUDINAL d ,'DUL`E�� ;9L8S ADDRESS: 180 PLEASANT D2 9. SEE SHEET 0.103 FOR DWENSKN4(S) AooREss.180 THA PTO,MA 2 NOT TO SCALE 10. FMN.FIRE OFFSET:NO FIRE CODE ENFORCED EASTHAAPTON.MA 01027 11. RIFTER SPACING:2494.O.C. 12. RiFTER SIZE:2X8'NOMINAL UC,NO.: MA 192102 13. LAG DOLT DIAMETER:51161N. 14. LPG BOLT EMBEDMENT:41N. w-NO.: RACKING DETAIL TRANSVERSE SONFRL 15. TOTAL AREATTACHMENTSSQ.FT. 9 SLE : OF Pa D1 RAIL 16. TOTAL WEIGHT T67.38S0.FT DRAWNGSE�nHORZEDMT OOM 17. TOTAL WEIGHT-1146.08 LBS. DRANINGSETFOMCOIW TOR NOT TO SCALE 1B WEIGHT PER ATTACHMENT:19.43LBS. PERIA1TMOPU.&COPTw.croArsn 19. DISTRIBUTED LOAD:2.45PSF µoaeR sweat TPrrocrt`uws 3 20, MAX HORIZONTAL STANDOFF:481N. DAMAGES AND MSECUPONS. 21. MFX.JERTICAL STANDOFF. D O L NDSCAPE 391N..PORTRAIT 661N. NEW PV SYSTEM:9.300 kWp 22. STANDOFF STAGGERING:NO IP 23. RAIL 4ANUFACTURER(OR EOUN.):UNIRAC24 RML VEGEOALENT):SUNFRAME RAIL R V SSO 25. R+1L.VEIHT.O PL 27. L FOOT 27 MODULE CLEARANCE 3IIN MIN.,6INMAX. RESIDENCE 49 COLUMBUS AVE I O 2, NORTHAMPTON,MA 01060 ® APN:NHAMM:038BB:0149L:0001 DETAIL ISOMETRIC) ENGINEER OF RECORD D"{{//���� NOT TO SCALE � RACKING DETAIL TOP D3NOT TOSCALE 5 0 PAPERSUE irorv)a B) ASSEMBLY DETAILS DATE: 07.232019 DEIGN BY:V.D. CHECKED BY: M.M. S DETAIL TRANSVERSE DETAIL LONGITUDINAL REVISIONS D4NOT TOSCALE D5 NOT TOSCALE S-501.00 A -- B C1F D E F G H ISWEET B) A _.- B C D E F G H Q SHEET KEYNOTES DSI D5 4INSIGHTI- 1. ROOF MATERIAL ROLLED ASPHALT 2. ROOF STRUCTURE. KNEE WALL 18 10 4 5 6 3. ATTACHMENT TYPE: BALLASTED 4. MODULE MANUFACTURER:CERTAINTEED SOLAR 03 5. MODULE MODEL:CT310M10-03 6. MODULE LENGTH:65.75 IN. 7. MODULE WIDTH:39.37 IN. .;A+ CONTRACTOR 8. MODULE WEIGHT:41.7 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 2 10. MIN.FIRE OFFSET:NO FIRECODE ENFORCED INSIGHT SOLAR 11. TOTAL#OF ATTACHMENTS:9 12. TOTAL AREA 71.9 SO.FT. PHONE: 41A38.7555 13. WEIGHT PER ATTACHMENT: ENT. EE] RACKING DETAIL (TRANSVERSE) 1TOTAL WEIGHT: 32 MS.29B LBS. ADDRESS:180 PLEASANT ST,SUITE 2 4. 15. FASTHAMPTON,MA 01027 DISTRIBUTED LOAD:2.45 PSF. 16. STANDOFF STAGGERING:NO 5501 SCALE:NOT TO SCALE 17. RACKING MANUFACTURER(OR EOUN.1:ECOLIBRIUM 18. RACKING MODEL:ECOFOOT5 UC.NO.: MA 192102 19. RACKING WEIGHT:TYPICAL 2.4.7.7 PSF HIC,NO.: 20. MAX.RAIL SPAN:48 IN. ELE NO.: 21. MAX.RAFTER SPAN:8 FT. UNAUTWIMMUSE OFTHIS oRAv"sEr mTNOUr wRmEN PERMISSION FROM CONTRACTOR IS IN WIND DEFLECT OR AMS`K�EC�CIVIL s 3 CAMAW AM PROSECUTIONS. -------- NEW PV SYSTEM:9.300 kWp RUSSO RESIDENCE D2 RACKING DETAIL(LONGITUDINAL) 49 COLUMBUS AVE s sol SCALE.NOT TO SCALE NORTHAMPTON,MA 01060 APN:NHAMM:038BB:0149L:0001 4 Q ENGINEER OF RECORD i 10 � MODULE CLAMP 5 RAPERSIZE ll'.Tr Wall) ASSEMBLY DETAILS © DATE: 07.23.2019 DESIGN BY:V.D. D3 I RACKING DETAIL(TOP) n DETAIL(TRANSVERSE) DS DETAIL (TRANSVERSE) CHECKED BY: M.M. $-501 SCALE:NOT TO SCALE Sal SCALE:NOT TO SCALE $-501 SCALE:NTT To SCALE REVISIONS 6 S-502.00 (SHEET 10)A �" B C D E F G H A IN B C IN D IN E IN F G IN H _. . INSIGHTS CertainTeed SolarO Electrical Characteristics 295W 30OW 305W DOW SERIESCT • . CELL Nominal Output(Pmpp) W 295 300 305 310 SOLARVoltage at Pmax(Vmpp) V 32.1 32.5 32.9 33.3 CONTRACTOR Current at Pmax(Impp) A 9.2 9.2 9.3 9.3 Open Circuit Voltage(VPC) V 39.9 40.3 40.7 41.1 INSIGHT SOIAR snots eHcan Cgrrem Osc) A 9.7 9.8 9.8 98 PHONE: 413.33&7555 Output Tolerance w .a.§9,-0 ADDRESS:180 PLEASANT ST,SUR2 No.or Celts B Connections 60m sones with 3 bypass diodes EASTHAMPTON.MA 01027 Maximum Series Fuse Rating 20A 20A 20A 20A fil LIC.NO.: MA 192102 Cell Type 6"Monaryitalllne ELHICE NO.:.NO.: Module Efficiency % 17.795 18.0% 15.3`6 18.6% UNAUTHONIZED USE OF THIS Temperature Coefficient of PmPP %/C .0.37 DRAINING SET%M HOUTw8IT1EN PERMISSION FROM CONTRACTOR IS IN AOL ION OF us COPYRICsHT UWS Temperature Coefficient of Voc %/C - -0.2S AND A L BE SUBJECT TO CML 3 �. • Temperature Coelfu lent Of Iw %/C - O.O$ DAMAGES xND PROSECUTIONS. NEW PV SYSTEM:9.300 kWp Mechanical Characteristics t Dimensions ROSS® ® Monocrystalline Type Laminate Glasr 3 2 high tiansrmsslon. Pein Hate. mir ��-- es f� �7 tempered,ami- Ilecttve RESIDENCE CT295MXX-03 Eucapsulanl'EVA Aindanse, CT300MXX-03 Backsheet Weatherproof Iihn O CT305MXX-03 (Black pr White) genii 49 COLUMBUS AVE CT310MXX-03 016 ) NORTHAMPTON,MA 01060 UPower Output Frame Anod—d aluminum(Black)P II APN:NHAMM:038B6:0149L:0001 0• a olo licit c . gen:wr Warranty Junction Box HoSe.IEC certified,UL listed G—di 4 wleearlsn.a.,�lex.t Output Cables 4 mm'(12AWG)PV Wife. Mark x2�I NYbw Length l.Om(39.4") •— " ""^••"" Conneclol5 Polarized MC4 compatible „a J I ENGINEER OF RECORD Features and Benefits I a"" n m Weatherproof.IEC cerf,hrd,UL fisted 0.20' 8 High Quality/High Power Weigh[ 18.9 kg(41.]lbs) ( (.) tXae' Up to 310W n Operating Conditions UL listed(UL 1703) Nominal Operating Cell Temp 46"C+2 e Output Domer tolerance.4.99/-OW 21- PID Free u�m c l N.]T Operating Temperature -40 to 85°C *Drs `M`en nNueiiq Mn 5 Maximum System Voltage 15001 C qns hon PAPERSIZE it'e ITyN5181 Lneked Warranty Fire Performance Type I e 10-ywproduct warranty Maximum Wind Load 50 lbs/fV(2400Pa) RESOURCE DOCUMENT e 25-year linear power output warranty Maximum Snow Load 112 lbs/ft'(5400 Pa) DATE: 07.23.2019 DESIGN BY:V.D. c ML us CertainTeed CertaldreedCorporation CHECKED BY: M.M. tiSTfO splNi.GOepiN ""•• Cfi1LIM0l O CKING•FRNCR•GYPIIIJ.•IN..LAT—•RAILIRG•ROOFING•.IOING•TRIM — SAINT-GOBAIN Proin.r>nnii--weG c—ece-a-enT r«u«t«Gea« REVISIONS 5 e.isunw4!Ol�tw+w.NXNJ xilhl6t faietb Y1 UFOS.N.Ih R-001.00 B C D E F G H (SHEET,n A ea B re C re D E F G H INSIGHT bnla Slue) Enphase IQ 7 and IQ 7+Microinverters Enphase Microinverters INPUT DATA(DC) 107.60.2-US 107.60-01-11S 107PLUS-72-2-US R 1107PLUS-72-S-US <qmn Af�1Fmm NiCAS Coonly usedmod lep rings_._____ . _ _ _.-._. _ _.._... 235W�350 W-. 235W 440 W♦ Module contponloloy 60-cell PV modules only 60-cell and 72-cell PV modules Mar,mum ntput DC voltage 43V 60 V Peak power tracking voltage 27V-37V 27 V.45V CONTRACTOR 01-aungiangc 16V 40V 16V-66V __.__............._........_._.__..._..__.._. _.__. _..__.__._ Mm/Mar sial l voltage 22 V746V 22 V/60V Ma,DC short c-tat current(module Isc) 15A ISA INSIGHT SOLAR 2 The high-powered smart grid-ready over voltage cls'Dc port B x Enphase oc pwt backfeed cupam 0A 0A PHONE: 413-338-7555 Enphase IQ7Micro'"and Enphase IQ7+Micro' pvauayr-on69watmn I.Iungrounded apay,NoaddnmmlDCside pralectanrequired Q7 and IQ 7+ dramatically simplify the Installation process while AC side protection requdes mas 20A pe branch ctrcint ADDRESS:180 PLEASANT ST SUITE 2 achieving the highest system efficiency. OUTPUT DATA(Ac) IO 7 Mkroinverrer IQ 7*Nlcroln oular EASTHAMPTON,MA 01027 Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and 6lasmuln-m—ous pdq,ut power 240 VA 290VA Nominal(LL)voliage/range' 240 v/ 208V/ 240 V/ 2011V/ LIC.NO.: MA 191102 IQ 7+Microinverters integrate with the Enphase 211-264 v 183229 V 211-264 V 183229 V HIC.NO.: IQ Envoy',Enphase IQ Battery'",and the Enphase Marmdm continuous output current 10 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) ELE.NO.: Nominal frequency 60 Hz bO Hz UNAUTnUd2E0 USE OF TNS Enlighten'monitoring and analysis software. Extended frequency range 47-68W 47.68-k DRAw1NG s6r vnTltouT vm1TTrN Ac Sher t circuit fault current over 3 cycles S9Amur 5.8 Arms PFRIASaON FROII C I`PACTOR IS IN IQ Series Microinverters extend the reliability Maximum units per 20 A(LQ branch circuit' 16(240 VAC) 13(208 VAC) 13(240 vAC) n(200 VAC) v)OIApON E Sd COPYRIGHT Uws AND N10 SE SUSIECT TO CNN 3 standards set forth by previous generations and Overvoltage class AC port III III Dii AGES AND PROSECUTIONS. undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor seamy 1.0 1.0 NEW PV SYSTEM:9.300 kWp enabling Enphase to provide an industry-leading Powe,rattor(adjustable) 0.851eading...0.85 lagging 0.85[.or ng...0.851a an warranty of up to 25 years. EFFICIENCY !P240 V 0208 V @240 V @208 V RU SS® 97.6:. 976. 975E 97.35 CEC weighted efficiency 97.0% 9TD'�, 97.0% 97.0-4 MECHANICAL DATA RESIDENCE: Amh ant temperature range_'_--_�– -AO°C to•65°C Relative humidity range 4:to 100`,0(condensing) Easy to Install Connector type(107-60-2-USa 107PLUS 722 US) MC4 for Amphenol H4 UTX with additional C-DCG-5 adapter) 49 COLUMBUS AVE Connector type(Ioa60 B US61Q7PLUS-72-8 US)Friends PV2(MC4 mtermaleable) NORTHAMPTON,MA 01060 •Lightweight and smple Adopiors for modules with MC4 or UTX ton 8c tors. •Faster installation with improved.lighter two wire cabling PV2 to MCA'order ECA S20S22 APR NHAMM:038BB:0149L:0001 -PV2 to UTX order ECA-S20-S25 4 Built-in rapid shutdown compliant(NEC 2014 B 2017) Dnnensums(WxH,D) 212 mm z 175 mm,30.2 mm(vnthoul bracket) 7 Weight 1.081 g(2 38 His) Productive and Reliable Coaling Natural convection-No fans ENGINEER OF RECORD Approved for ,at locations Yee NDC •optimized for high powered 60 cell and 72 cell-modules Pollution degree PD3 •More than a million hours attesting Enclosure Class Il double Insulated,c o sron resistant polymeric enciosme •Class 11 double insulated enclosure Envbonmenlal Category/UVasposusratutp NEMA Type 6/outdoor •UL listed FEATURES Commumcatrorl Power lute Communication(PLCf Monitoring Enbghteu Manager and MyEnbghten,nannorog options Smart Grid Ready Both options requ re mstallnuot of an Enphase 10 Envoy co Dlsnnecunymeans The AC and DC cnnneclmc have been evaluated and approved by UL for use as the load-break •Complies with advanced grid support,voltage and disconnect—loi ed by NEC 640 frequency nde-through requtremenis C-ompliantr CA Mule 21(UL 1741 SA) ilic •Remotely updates changing respond to chanyg UL 621091,UL1741/IEEE1547,FCC Pan 15 Gas.9,ICES-0003 Class B. PAPER sae ir,1r(AND e) 5 CAN/CSA C222 NO 1071 01 gild reywrnnents This product is UL Listed as PV Rapid Shut Oovn Equrpmenr and conlorms with NEC 2014 and •Config—ble for varying grid profiles NEC-2017 section 690 12 and C72 1-2015 at 64218 Rapid Shutdown of PV Systems,for AC RESOURCE DOCUMENT •Meets CA Rule 21(UL 1741-SA) and DC conductors.when installed according manufacturer's Instructions. - - U` roe lir r.Mcry s mgvacn rP•anna,n r2-crux mndwe. Hu 1mma:d uunc,au„sec um.wnP.nune,r<.ro:nitJu.iar ntros mnphase com,en vasvnomt,aroovtromupopeay DATE: 07131019 l Nan ural voltunc lunge can lie t•enae4 beyunnd.m e,luue4Ny OIL trimly T Lnnvtsmay vmy Rele1 m tmal 1-11wnelns to 1Jtfa ,beuwnbe,u1.n.cm.n.e srel nano,.o yaw are. DESIGN BY:V.D. E N P H A S E To learn more about Enphase offerings,visit enphase.com v E N P H A S E CHECKED BY: M.M. To learn more about Enphase offerings,visit enphase.eom nnRen+n°+•Fn<rvy.lxnnm,­„rvlAnl,.,e••nn ur:,moor..t,,.rn•„a,,iynEnlA,:,+eEnwm•.x, REVISIONS marvw 6 Rm002.00 A ae B reC reaD reE reF reGreH (SHEET 121 A exseCas D ex E F G H j&INSIGHT Enphase Networking Enphase IQ Combiner MODELNUMBER IQ Combmer XiQ-AMI-240.8 IO Combiner with Enphase lO Emmy formtegrated revemte grade Pv production metering (ANSI C12.20 /O.S%)and optfonalconurmption monnorliIi 2.511). CONTRACTOR ACCESSORIES(order separately) The Enphase IQ Combiner-with Enphase 10 Envoy"' Enphase Mobile Connect" Plug and play industrial grad cellular male with Five-year data plan for systems up to 60 INSIGHT SOLAR 2 Enphase CELLMODEM 01(3G) where err rs(Available in the US Camila Mexico,Puerto Rico.and the US Virgin Islands, Consolidates interconnection equipimeflt into a CELLMODEM 03(4G) there is adequate cellular Service it 0e installation area.) Q Combiner single enclosure and streamlines Pt/installations by Consumption Monitoring CT Split core current transformers enable Wrote home consumption metering( 2.511). PHDNE: 413338-7555 CT-200 SPLI r ADDRESS:160 PLEASANT ST.SUITE 2 (X-I10-AM1-240-B) providing a consistent,prewired solution for residential ELECTRICAL SPECIFICATIONS EASTHAMPTON,MA 01027 applications Rating Continuous duty Solar branch circuit breakers Three 2 pole 20 A/240 VAC DM rad-mounted breakers fir LK.NO.: MA 192102 Maximum system voltage 240 VAC HIC.NO.: Rated output current 48 A ELE.NO.: Rated input current.each input 16 UNAUTHORIZED,SEOFTNIS DRAWING SET WITHOUT WRITTEN Maximum[use/circuit breaker rating(output) 60A PERMSSON FROM CONTRACTOR IS IN NOU,TION OF Us COPYRIGHT LAWS Production Metering CT 200 A solid core pre-installed on solar blsbar and,vired to IQ Envoy ANDAILLBESUBJECTTO CML DAMAGES AND PROSECUTIONS. 3 MECHANICAL DATA Dimensions(WXHXD) 38.0 x 38.7 x 20.3 dm(15.0"x 153-IT 8.0") NEW PV SYSTEM:9.300 kWp —' - Weight 5.1 kg(11.2 lbs) Ambient temperature range -40°C to.46"C(-40°to 115°F) RUSSO Smart Cooling vented,natural convection,plus heat shield Enclosures -ratentalrating Outd—,NRTL..hfied.NEMA type 3R,Imlyearbonateconstruction RESIDENCE •Includes IQ Envoy for Communication and control Wire Size 14 t0 4 AWG copper conductors for tranitconcur inputs latoaAWGcopperquite entsnorcommnaioutput 49 COLUMBUS AVE •FlexiGe nelworkmy supports N/i-Fi. Follow local code requirements for cunduclor sizing I Ethernet.or cellular Altitude To 2000meters(6,560feet) NORTHAMPTON,MA 01060 INTERNET CONNECTION OPTIONS APN:NHAMM:038BB:0149L:0001 4 Simple Integrated W.F. 807.111s/g/n •Three pre-installed 20 A/240 VAC Ethernet 802.3,CatSE(or Cat 6)UTP Ethernet cable-rot included circuit breakers Cellular Optional,CELLMODEM-01(3G)w CELLMODEM 03(4G)-riot included ENGINEER OF RECORD astatine COMPLIANCE I •Provides Production metering and I. consumption monitoring. Compliance.Combiner UL 1741 l Compliance.IQ Envoy UL 916 CAN/CSA C22.2 No.61010-1 Reliable 4/CFR,Part 15,Class B.ICES 003 IEC/EN 6/0101 2010. •Durable NRTL certified NEMA type ENS0065-1,EN61000-4 5,EN61000-6.I,L-N61000-6.2 3R enclosure Metering ANSI 012.20 accuracy class 0.5 •Five year warranty 5 PAPER WE ir.iT(ANSN B) RESOURCE DOCUMENT DATE: 07.232019 U� DESIGN BY:V.D. To learn more about Enphase offerings,visit enphase.com CHECKED BY: M.M. LISTED ENPHASE. ;^OirylEMraxLrciOY.ulrgnr ""'aA':oaet. xi:-o.I .,.,nm:,a�aw�ia:: .,,,1Idb:n,:•i,:.:. ENPHASE To learn more about Enphase offerings,visit enphase.com RENSIONS 6 R-003.00 A se 9 seC asD asE asF asG asH (SHEET til A B C D E F G H 4#INSIGHT SUNFRAME ads UNIRAC SUNFRAME CONTRACTOR SUNfRAMF is a shared rail system with gap free rows that boasts a sleek,low profile design.The refined CAPSTRIPi INSIGHT SOLAR 2 AESTHETIC DESIGN &SCREWS aesthetics are valued by discerning homeowners and architects for residential and light commercialMADITO FIT YOURROOF PHONE: 413- 67555 applications. Our system is compatible with many attachment options, including Unirac standoffs folADDRESS:180 PLEASANT ST,SUITE 2 installation on comp shingle or tele roofs.Modules are fully supported between shared rails,allowing for a EASTHAMPTON.MA01027 streamlined install to achieve a seamless,refined look. LIC.ND.: MA 192102 HIC.NO.: AVAILABILITY ELF NO.: ~HOR M USE OF THIS NATIONWIDE NETWORK PMWW.SET WITHOUT WRITTEN PERMISSION FROM CONTRACTM B M NOLATION OF U.S.COWRM.NT TAWS Ma MIO M L BE SUBJECT TO CNS 3 wAUBEs MIB INN>SEcuTUNs. �.' NEW PV SYSTEM:9.300 kWp AUTOMATED ' " I I' I I RUSSO RESIDENCE UPS49 COLUMBUS AVE •11�OFRE'' � NORTHAMPTON,MA 01060 RAR APN:NHAMM:038BB:0149L:0001 4 9UL2703 ENGINEER OF RECORD UNIRAC CUSTOMEROF PRODUCTSUPPORT -._._— ---- 5 WERSIZE II•.IryMSIBI RESOURCE DOCUMENT SLEEK LOW PROFILE DESIGN DATE: 07.232019 REFINED DESIGN TOOLSOUALITY "PROVIDDESIGN BY.V.D. CHECNED BY: M.M. RENSIONS 6 R-004.00 A B C D E F G H (SHEET 14) A B C D E F G H INSIGHT2- �+ CONTRACTOR Unirac Flat Flashing 2 INSIGHT SOLAR INSTALLATIONMANUAL PHONE: 413-338-1555 ADDRESS:180 PLEASANT ST,SURE 2 EASTHAMPTON,MA 01027 UC,NO.: MA 192102 NIC.NO.: cC 2011 by Unirac,Inc.All ngus reserved. ELE.NO.: Pub 110525-Iii,May 2011 I1 UTHIAZED USE OE THIS DRAMANG SET..IOMEN PERMISSON FROM CONTRACTOR IS IN NOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUIKIECT TO CNIL 3 DAMAGES AND PROSECUTIONS. NEW PV SYSTEM:9.300 kWp RUSSO RESIDENCE 49 COLUMBUS AVE NORTHAMPTON,MA 01060 F.e APN:NHAMM:038BB:0149L:0001 4 .. ENGINEER OF RECORD 5 PAPERSa II-,IT(ANSI8) $ 4 r 4 _ RESOURCE DOCUMENT DATE: 07.232019 DESIGN BY:V.D. me ® 1411 Broadway Boulevard NE CHECKED BY: M.M. ii i 6 UNIRACAlbuquerque, NM 87102-1545 USA REVISIONS R-005.00 A B C D E F G H (SHEET 151 A B C D E F G H INSIGHTS F00 :Max Out Your Roof i co CONTRACTOR D INSIGHT S" 2The New High Density Racking System 5 Simple Components.1 Sweet System. At11:14sup111M FNDNE, 413.338.7555 K Ali 180 HSASAIIT ST,SUITE 1 EASTMWTON,MA 01017 A �Na: Small Footprint. Big Power. '�'� `�' HIC.NO.: Ballast Tray . ELE Ill LkWnlolaZEo USE of Tkls Mill W114013111111111" Now you can build more cERMSSM ERor.I CONTRACTOR IS IN powerful rooftop solar Fdl LAM ANDMUSESON OF uiaSiECT�roc it 3 systems faster and easier �.. DAMAGES AMO PROSECUTIONS. than ever before with jr NEW PV SYSTEM:9.300 kWp the new high density EcoFoot5D1 t iRUSS� Racking System. Foo[5D Base It RESIDENCE Eco t 49 COLUMBUS AVE Preassembled Universal Clamp wind NORTHAMPTON,MA 01060 Built on the Industry-Preferred EcoFoot®Platform,with More than 20OMW Installed. Defl8C0of APN:NHAMM:0388B:0149L:0001 Wire Management in a Snap. €;ailast Piacement that Beats All. ENGINEER OF RECORD Accessible&Protected Ergonomic,Cost-Saving and Fast rSimply snap wire clips into Base to route wires between rows. Place ballasts between rows for easy reach- No UV exposure:rax-[o-row wires covered by Ballast Tray No awkxard undermodule access • Easy access to wires during install and throughout Rapid Ballast Tray install,sliding into Base retention clips 18.4%More Power Elegantly Simple Installation Cost-Saving Logistics&Support the life of the system with removable Wind Deflector Ballast Tray strong enough to walk on.even Small 7"x16.7"roof-friendly EcoFoot5D delivers preassembled Stackable bases enable a huge and in-row ballast placement when loaded with ballast blocks modular Base and dense 9.9` parts and an out-of-the-box,ready- per-pallet shipping capacity.Fewer .va Minimal roof contact means smaller slip inter-row spacing enables a to-go installation that Is unlike any pallets are required,minimizing a-► sheets,)—ring casts tightly packed solar array that other Kat-roof racking.The result shipping,storage and onsite crane delivers 18.4%more power than is a seamless installation process use.Dedicated engineering support } 5 10'systems.Whether your roof from start to finish,saving on time prevents issues before they happen %6PAPERSIZIE.n•:r(All l is small or large-EcoFoot5D and minimizingjob-site impact- and provides quick solutions if provides more power,lowering obstacles arise. RESOURCE DOCUMENT cost-per-watt. DATE: 07.232019 1 DESIGN BY:V.D. Ecolibrium5ci: CHECKED BY: M.M. Contact:740-249.1877 1 sates@ecoiibriumsolar.com I www ecolibnumsolar.com REVISIONS 6 R-006.00 A B _ D E F ., H ISN 16)