Loading...
02 -002 15051733B-Kennedy_Truss-DwgsOVERHANG INFO HEEL HEIGHT GABLE STUDS 01-00-00 0 IN. OC END CUT RETURN PLUMB REQ. ENGINEERING JOBSITE REQ. LAYOUTS JOBSITE 2 1 QUOTE LAYOUT CUTTING BT1 BT1 DATEBY SHIP TO 24 West St Hatfield, MA 01038 R.K. Miles-HatfieldSOLD TO (413) 247-8314 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / / / / /ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # LMCWRKMI ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 15051733B Brian Tetreault Massachusetts / / / Rich Blaise (413) 247-8314 PAGE 1 SPECIAL INSTRUCTIONS: DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG: Kennedy Residence /Construct BUILDING DEPARTMENT Roof Trusses JOB CATEGORY: Residential LOT # SUBDIV: DATE05/14/15 705 North Farms Road Florence, MA 01062 Kennedy Residence Rich Blaise 05/14/15 05/14/15 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5257 UFP Belchertown, LLC QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN S01 5.00 3.00 24-00-00 01-00-00 01-00-002 X 6 2 X 6 SCISSORS 5 24-00-00 S01GE 5.00 3.00 24-00-00 01-00-00 01-00-002 X 6 2 X 6 GABLE 1 24-00-00 T01 5.00 0.00 24-00-00 01-00-00 01-00-002 X 6 2 X 4 COMMON 12 24-00-00 T01GE 5.00 0.00 24-00-00 01-00-00 01-00-002 X 6 2 X 4 GABLE 1 24-00-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY: TITLE: ADDRESS: PHONE: DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL Truss ListTruss Qty SpanS01 5 24' 0"S01GE 1 24' 0"T01 12 24' 0"T01GE 1 24' 0"S01GET01GES01(5)T01(12)24' 0" 24' 0" 36' 0"11' 6"24' 6"1' 11 1/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"Roof Area 1062.12Sheathing Count 37Overhang Lines 75.42Raked Lines 56.33Ridge Lines 37.71Hip Lines 0Valley Lines 0THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to beincorporated into the building design at the specificationof the building designer. See individual design sheets for eachtruss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracingof the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams,walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing ofwood trusses" available from the Truss Plate Institute, 583D'Onifrio Drive; Madison, WI 53179. It is the responsiblility of theGeneral Contractor/Superintendent to verify that the provided truss layout shall match the final intended construction plans,loading conditions, and use. If they do not, it is the responsiblility of the General Contractor/Superintendent to provideprints/plans containing the latest specifications and designs. Universal Forest Products will not be responsible forprint/planchanges by others after final approval ofshop drawings, norwill they be responsible for errors or modifications made on-siteduring construction. DO NOT CUT, NOTCH, DRILL, OR OTHERWISE"REPAIR" MANUFACTURED TRUSSES IN ANY WAYWITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. UFP WILL NOTBE HELD RESPONSIBLE FOR ANY MODIFICATIONS OR "CHARGE BACKS"DONE WITHOUT PRIOR WRITTENAUTHORIZATION FROM UFPKennedy Addition705 North Farms Rd. Florence, MA5/14/15For Approval15051733BThe following information is anapproximate and NOT guaranteed Job 15051733B Truss S01 Truss Type SCISSORS Qty 5 Ply 1 Florence, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Thu May 14 12:06:06 2015 Page 1 Universal Forest Products ID:cOX4s?qSwjx0ymuRsuNiPQzGcMZ-2kZJR3fUUo_EdurV0hIaTYW478D1b7W5xCtTOmzGc_F Scale = 1:42.2 T1 T1 B1 B1 W2 W1W1 HW1 HW11 2 3 4 5 6 7 8 9 10 19 20 6x8 4x8 6x8 4x8 6x6 8x8 2x4 2x4 12-0-012-0-0 24-0-012-0-0 -1-0-0 1-0-0 8-1-14 8-1-14 12-0-0 3-10-2 15-10-2 3-10-2 24-0-0 8-1-14 25-0-0 1-0-0 1-0-06-0-01-0-02-10-105.00 12 3.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-2-4], [8:0-0-9,0-3-15], [10:0-4-0,0-4-4] LOADING (psf)TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI. TCBCWB(Matrix-M) 0.460.430.92 DEFL. Vert(LL)Vert(TL)Horz(TL)Wind(LL) in-0.31-0.500.320.10 (loc)1010810 l/defl>941>577n/a>999 L/d240180n/a360 PLATES MT20 Weight: 113 lb FT = 4% GRIP 197/144 LUMBER-TOP CHORD 2x6 SPF 2100F 1.8EBOT CHORD 2x6 SPF 2100F 1.8E WEBS 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x4 SPF Stud or No.2 2-5-12, Right 2x4 SPF Stud or No.2 2-5-12 BRACING-TOP CHORD Structural wood sheathing directly applied or 4-0-9 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1540/0-5-8 (min. 0-2-7), 8=1540/0-5-8 (min. 0-2-7) Max Horz2=-61(LC 9)Max Uplift2=-75(LC 8), 8=-75(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-1470/87, 3-19=-4174/748, 4-19=-3999/768, 4-5=-3604/573, 5-6=-3604/573, 6-20=-3999/768, 7-20=-4174/748, 7-8=-1470/87BOT CHORD 2-10=-608/3815, 8-10=-608/3815WEBS5-10=-283/2135, 6-10=-656/260, 4-10=-656/260 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other liveloads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottomchord and any other members.7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8.9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15051733B Truss S01GE Truss Type GABLE Qty 1 Ply 1 Florence, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Thu May 14 11:58:00 2015 Page 1 Universal Forest Products ID:cOX4s?qSwjx0ymuRsuNiPQzGcMZ-HEBaRtnexUlBJCh5Ycacm3O7BERkjXSYBb9lKwzGc5r Scale = 1:42.2 T1 T1 B1 B1 HW1 HW1 ST5 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1524 23 22 21 20 19 18 17 16 25 26 6x6 4x6 4x4 5x6 4x6 4x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-0-012-0-0 24-0-012-0-0 -1-0-0 1-0-0 12-0-0 12-0-0 24-0-0 12-0-0 25-0-0 1-0-0 1-0-06-0-01-0-02-10-105.00 12 3.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-4-2], [14:0-2-6,0-4-2], [20:0-3-0,0-3-8] LOADING (psf)TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI. TCBCWB(Matrix) 0.050.020.07 DEFL. Vert(LL)Vert(TL)Horz(TL) in-0.00-0.000.00 (loc)151514 l/defln/rn/rn/a L/d18080n/a PLATES MT20 Weight: 116 lb FT = 4% GRIP 197/144 LUMBER-TOP CHORD 2x6 SPF 2100F 1.8EBOT CHORD 2x6 SPF 2100F 1.8E OTHERS 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x4 SPF Stud or No.2 2-1-12, Right 2x4 SPF Stud or No.2 2-1-12 BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 24-0-0. (lb) - Max Horz2=-49(LC 9)Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 21, 22, 23, 24, 19, 18, 17, 16Max Grav All reactions 250 lb or less at joint(s) 20, 23, 17 except 2=356(LC 1), 14=356(LC 1), 21=325(LC 2), 22=324(LC 2), 24=408(LC 2), 19=325(LC 3), 18=324(LC 3), 16=408(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 7-21=-284/71, 6-22=-280/86, 4-24=-321/134, 9-19=-284/71, 10-18=-280/86, 12-16=-321/134 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other liveloads.6) All plates are 1.5x3 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 21, 22, 23, 24, 19, 18, 17, 16. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 20, 21, 22, 23, 24, 19, 18, 17, 16. 13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.14) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15051733B Truss T01 Truss Type COMMON Qty 12 Ply 1 Florence, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Thu May 14 12:08:08 2015 Page 1 Universal Forest Products ID:cOX4s?qSwjx0ymuRsuNiPQzGcMZ-TDxQ2n70lHLwGeAx9JUBPGZwlJmfATA2?ARwghzGbyL Scale = 1:41.8 T1 T1 B1 W2 W1 W2 W1 HW1 HW1 B2 1 2 3 4 5 6 7 8 9 11 10 20 21 22 23 6x6 4x8 4x6 5x6 2x4 3x4 2x4 4x8 4x6 8-0-0 8-0-0 16-0-0 8-0-0 24-0-0 8-0-0 -1-0-0 1-0-0 6-1-12 6-1-12 12-0-0 5-10-4 17-10-4 5-10-4 24-0-0 6-1-12 25-0-0 1-0-0 1-0-06-0-01-0-05.00 12 Plate Offsets (X,Y)-- [2:0-4-13,0-1-6], [8:0-4-13,0-1-6], [10:0-3-0,0-3-0] LOADING (psf)TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI. TCBCWB(Matrix-M) 0.500.810.31 DEFL. Vert(LL)Vert(TL)Horz(TL)Wind(LL) in-0.26-0.440.090.05 (loc)10-1110-11810-11 l/defl>999>647n/a>999 L/d240180n/a360 PLATES MT20 Weight: 110 lb FT = 4% GRIP 197/144 LUMBER-TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 2-5-12, Right 2x6 SPF No.2 2-5-12 BRACING-TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1585/0-5-8 (min. 0-2-8), 8=1585/0-5-8 (min. 0-2-8) Max Horz2=-61(LC 9)Max Uplift2=-75(LC 8), 8=-75(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-536/33, 3-4=-2471/473, 4-20=-2236/441, 5-20=-2230/464, 5-21=-2230/464, 6-21=-2236/441, 6-7=-2471/473, 7-8=-536/33BOT CHORD 2-11=-333/2173, 11-22=-177/1636, 22-23=-177/1636, 10-23=-177/1636, 8-10=-333/2173WEBS5-10=-95/728, 6-10=-469/187, 5-11=-95/728, 4-11=-469/187 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other liveloads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottomchord and any other members, with BCDL = 10.0psf.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8.8) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15051733B Truss T01GE Truss Type GABLE Qty 1 Ply 1 Florence, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Thu May 14 12:08:27 2015 Page 1 Universal Forest Products ID:cOX4s?qSwjx0ymuRsuNiPQzGcMZ-Qsac1GMwH7kD2Z7bmoJfhHsGZzRN75erMeXQr5zGby2 Scale = 1:41.8 T1 T1 B1 HW1 HW1 B2 ST6 ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST112 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 28 27 26 25 24 23 22 21 20 19 18 29 30 6x6 3x8 4x4 3x8 3x4 5x6 24-0-0 24-0-0 -1-0-0 1-0-0 12-0-0 12-0-0 24-0-0 12-0-0 25-0-0 1-0-0 1-0-06-0-01-0-05.00 12 Plate Offsets (X,Y)-- [2:0-5-1,0-2-10], [16:0-5-1,0-2-10], [21:0-3-0,0-3-0] LOADING (psf)TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress IncrCode 2-0-01.151.15YESIRC2009/TPI2007 CSI. TCBCWB(Matrix) 0.070.030.14 DEFL. Vert(LL)Vert(TL)Horz(TL) in-0.00-0.000.00 (loc)171716 l/defln/rn/rn/a L/d18080n/a PLATES MT20 Weight: 122 lb FT = 4% GRIP 197/144 LUMBER-TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 or 2x4 SPF Stud OTHERS 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 1-7-10, Right 2x6 SPF No.2 1-7-10 BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 24-0-0 except (jt=length) 2=-0-0-1 (input: 24-0-0), 16=-0-0-1 (input: 24-0-0), 23=-0-0-1 (input: 24-0-0), 24=-0-0-1 (input: 24-0-0), 25=-0-0-1 (input: 24-0-0), 26=-0-0-1 (input: 24-0-0), 27=-0-0-1 (input: 24-0-0), 28=-0-0-1 (input: 24-0-0), 22=-0-0-1 (input: 24-0-0), 21=-0-0-1 (input: 24-0-0), 20=-0-0-1 (input: 24-0-0), 19=-0-0-1 (input: 24-0-0), 18=-0-0-1 (input: 24-0-0).(lb) - Max Horz2=-49(LC 9)Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18Max Grav All reactions 250 lb or less at joint(s) 23, 27, 28, 19, 18 except 2=263(LC 12), 16=263(LC 12), 24=324(LC 2), 25=313(LC 2), 26=261(LC 2), 22=324(LC 3), 21=313(LC 3), 20=261(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 8-24=-284/68, 7-25=-273/84, 10-22=-284/68, 11-21=-273/84 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details asapplicable, or consult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other liveloads. 6) All plates are 1.5x3 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottomchord and any other members.11) WARNING: Required bearing size at joint(s) 2, 16, 23, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18 greater than input bearing size.12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18.13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.14) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard