Loading...
QuickAnalysis_0580_ Vadim Folokhin_333 Acrebrook Dr_Northampton DRAFT gQuick Analysis Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA Vadim Folokhin Colonial HERS_0073_0580_ Vadim Folokhin_333 Acrebrook Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS ProjectedWorstCase Rating No:0073-0580 Rater ID:8776762 Registry ID: Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Design Load (kBtu/hr) Heating 32.0 Cooling 14.9 Annual Load (MMBtu/yr) Heating 49.2 Cooling 3.0 Water Heating 11.5 Annual Consumption (MMBtu/yr) Heating 52.6 Cooling 0.8 Water Heating 3.1 Lights & Appliances 24.5 Photovoltaics -0.0 Total 81.1 Annual Energy Cost ($/yr) Heating 703 Cooling 36 Water Heating 132 Lights & Appliances 863 Photovoltaics -0 Service Charges 177 Total 1912 Total Area (sq ft) Conditioned Space 2880 Shell Area 5400 Above Grade Shell Area 3672 Foundation Wall 1024.0 Slab Floor 960 Floor 0 Rim And Band Joist 256.0 Above-Grade Wall 2152.0 Window 225.7 Total Area (sq ft) Door 60.0 Ceiling 1008 Skylight 0.0 Duct 1123.2 Ratios Window-to-Wall 0.105 Window-to-Floor 0.078 Window Area by Orientation (sq ft) North 95.9 Northeast 0.0 East 37.2 Southeast 0.0 South 92.6 Southwest 0.0 West 0.0 Northwest 0.0 Codes IECC 2018 Performance Fails IECC 2015 Performance Passes IECC 2012 Performance Fails IECC 2009 Performance Fails IECC 2006 Performance Fails IECC 2004 Performance Fails Iowa Code Fails Michigan Code Fails Illinois Code Passes NY-ECCC 2016 Performance Fails North Carolina Code Fails North Carolina HERO Fails Programs EPA ENERGY STAR 3.0 Fails Quick Analysis Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA Vadim Folokhin Colonial HERS_0073_0580_ Vadim Folokhin_333 Acrebrook Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS ProjectedWorstCase Rating No:0073-0580 Rater ID:8776762 Registry ID: Page 2 of 2 Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Programs EPA ENERGY STAR 3.0 Topics Fails EPA ENERGY STAR 3.1 Fails EPA ENERGY STAR 3.2 WA, OR Fails Tax Credit Fails DOE Zero Energy Ready Home Fails HERS Index (with IAF)55 IECC 2015 ERI 55 IECC 2018 ERI 55 WH Infiltration Natural ACH 0.16 ACH50 (Pa)3.00 CFM50 (Pa)1152 ELA (sq.in)63.2 SLA 0.00015 CFM50/sf shell 0.21 WH Ventailation (continuous) Type Exhaust Only AsIs (equiv. cfm)80 62.2-2010 (cfm)59 62.2-2013 (cfm)78