Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
QuickAnalysis 0580 _ Vadim Folokhin_333 Acrebrook Dr_Northampton DRAFT
Quick Analysis Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA BLANK 4 HERS_0073_0580_ Vadim Folokhin_333 Acrebrook Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS ProjectedWorstCase Rating No:0073--580 Rater ID:8776762 Registry ID: Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Design Load (kBtu/hr) Heating 32.0 Cooling 15.1 Annual Load (MMBtu/yr) Heating 48.8 Cooling 3.3 Water Heating 11.5 Annual Consumption (MMBtu/yr) Heating 52.2 Cooling 0.9 Water Heating 3.1 Lights & Appliances 24.8 Photovoltaics -0.0 Total 80.9 Annual Energy Cost ($/yr) Heating 698 Cooling 39 Water Heating 132 Lights & Appliances 872 Photovoltaics -0 Service Charges 177 Total 1918 Total Area (sq ft) Conditioned Space 3024 Shell Area 5344 Above Grade Shell Area 3568 Foundation Wall 1024.0 Slab Floor 1008 Floor 0 Rim And Band Joist 256.0 Above-Grade Wall 2048.0 Window 215.0 Total Area (sq ft) Door 40.0 Ceiling 1008 Skylight 0.0 Duct 1179.4 Ratios Window-to-Wall 0.105 Window-to-Floor 0.071 Window Area by Orientation (sq ft) North 80.8 Northeast 0.0 East 22.4 Southeast 0.0 South 80.5 Southwest 0.0 West 31.3 Northwest 0.0 Codes IECC 2018 Performance Fails IECC 2015 Performance Passes IECC 2012 Performance Fails IECC 2009 Performance Fails IECC 2006 Performance Fails IECC 2004 Performance Fails Iowa Code Fails Michigan Code Fails Illinois Code Passes NY-ECCC 2016 Performance Fails North Carolina Code Fails North Carolina HERO Fails Programs EPA ENERGY STAR 3.0 Fails Quick Analysis Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA BLANK 4 HERS_0073_0580_ Vadim Folokhin_333 Acrebrook Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS ProjectedWorstCase Rating No:0073--580 Rater ID:8776762 Registry ID: Page 2 of 2 Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Programs EPA ENERGY STAR 3.0 Topics Fails EPA ENERGY STAR 3.1 Fails EPA ENERGY STAR 3.2 WA, OR Fails Tax Credit Fails DOE Zero Energy Ready Home Fails HERS Index (with IAF)54 IECC 2015 ERI 54 IECC 2018 ERI 54 WH Infiltration Natural ACH 0.16 ACH50 (Pa)3.00 CFM50 (Pa)1260 ELA (sq.in)69.2 SLA 0.00016 CFM50/sf shell 0.24 WH Ventailation (continuous) Type Exhaust Only AsIs (equiv. cfm)80 62.2-2010 (cfm)60 62.2-2013 (cfm)78