Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
IECCUA15 0580_ Vadim Folokhin_333 Acrebrook Dr_Northampton DRAFT
2015 IECC Building UA Compliance Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA BLANK 4 HERS_0073_0580_ Vadim Folokhin_333 Acrebrook Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin HERS ProjectedWorstCase Rating No:0073--580 Rater ID:8776762 DRAFT REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings:26.2 20.8 Above-Grade Walls:124.9 119.1 Windows and Doors:81.6 69.9 Basement Walls:49.5 62.6 Overall UA (Design must be equal or lower):282.3 272.3 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1.2)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 16 January 2019 2015 IECC Energy Cost Compliance Property Vitaly dzhenzherykha 333 Acrebrook Dr Northampton, MA 01062 Weather:Chicopee, MA BLANK 4 HERS_0073_0580_ Vadim Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Vadim Folokhin HERS ProjectedWorstCase Rating No:0073--580 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.7.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. DRAFT Annual Energy Cost $/yr 2015 IECC As Designed Heating 752 696 Cooling 161 137 Water Heating 153 153 SubTotal - Used to Determine Compliance 1067 987 Mechanical Ventilation Fan 35 18 Lights & Appliances (minus MechVent)975 854 Photovoltaics -0 -0 Service Charge 177 177 Total 2254 2036 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 7.5%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 16 January 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.