Loading...
31A-083 302 ELM DDCD 2017-02-28This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP EXISTING SINK BOILER WATER HEATER EXISTING BASEMENT PLAN Scale: 1/8" = 1'-0"EX0 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP UP UP UP DN RAMP DOWN EXISTING 1ST FLOOR PLAN Scale: 1/8" = 1'-0"EX1 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP DN DN EXISTING 2ND FLOOR PLAN Scale: 1/8" = 1'-0"EX2 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 DN EXISTING THIRD FLOOR PLAN Scale: 1/8" = 1'-0"EX3 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP BOILER WATER HEATER EXISTING SINK INFILL EXISTING OPENING TO CRAWL SPACE COMPLETE INSTALLATION OF NEW BOILER, HOT WATER HEATER, MANIFOLD & ASSOC. MATERIALS.NEW PLUMBING CHASE, ABOVE. CONNECT TO EXISTING UTILITIES PATCH FLOOR @ DEMO'D CHIMNEY GENERAL NOTE: INSULATE EXISTING 1ST FLOOR / BASEMENT CEILING, R-19 PROVIDE ADDITIONAL SUPPORT FOR FLOOR ABOVE THESE AREAS PROPOSED BASEMENT PLAN Scale: 1/8" = 1'-0"A0 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP UP UP UP DN DW 14'-1 3/8"17'-4 7/8"4 3/4"14'-11 1/4"1'-1"3'-4"4'-7"1'-7 1/4"5'-8 1/2"3'-7 1/2"4'-4 3/4"2'-8"4'-11"2'-0 5/8"1'-8"4'-9 3/4"2'-5"3'-1" LIVING ROOMENTRY OFFICE / MUSIC ROOM DINING ROOM KITCHEN MUD ROOM PANTRY HALF- BATH CLOSET BREAKFAST NOOK STAIR HALL REFINISH EXISTING WOOD FLOOR REFINISH EXISTING WOOD FLOOR REFINISH EXISTING WOOD FLOOR REFINISH EXISTING WOOD FLOOR EXISTING WOOD FLOOR NEW WOOD FLOOR TO MATCH EXISTING 30"X84"REMOVE DOOR. CASED OPENING TO REMAIN. INFILL WOOD TRIM. REFINISH. REMOVE VALANCE HARDWARE AT WINDOW TRIM. INFILL WOOD. REFINISH. REMOVE VALANCE HARDWARE AT WINDOW TRIM. INFILL WOOD. REFINISH. NEW GUARD RAIL TO MATCH EXISTING ADJACENT GUARD RAIL REFINISH EXISTING PORCH & STAIRS NEW HARDWOOD FLOORING 2'-1" NEW SHALLOW CABINET WITH QUARTZ TOP NEW KITCHEN CABINETS, LOWER & UPPER. SLAB DOORS, QUARTZ COUNTER. PROVIDE CONNECTIONS FOR OWNER SUPPLIED DISHWASHER, REFRIGERATOR & STOVE NEW HARDWOOD FLOORING NEW HARDWOOD FLOORING NEW BUILT-IN SHELVING, PAINTED RESTORE/REFINISH EXISTING PANTRY CABINET REPAIR DOOR TRIM AT MUDROOM ENTRY ALIGN TILE REMOVE DOOR FRAME, INFILL OPENING RESTORE / REPAIR EXISTING FIRE PLACE NEW RELOCATED PLUMBING CHASE ALIGN NEW WOOD FLOOR TO MATCH EXISTING 30"X84"EXISTING WOOD FLOOR REFINISH EXISTING WOOD FLOOR ALTERNATE: REPLACE EXISTING WATER DAMAGED PORCH FLOORREFINISH EXISTING BULK HEAD TO REMAIN GENERAL NOTE: INSULATE EXISTING EXTERIOR WALLS, R-20 PROPOSED 1ST FLOOR PLAN Scale: 1/8" = 1'-0"A1 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 UP DN DN heated towelDWlow wall 21"x48" MASTERBATH LAUNDRY +/-11'-5 1/2"2'-7 1/4"4 3/4"+/-8'-5 1/2"+/-7'-0"4 3/4"7'-1 1/2" 4'-2"6'-0"4 3/4"7'-5 3/4"1'-10"CLOTHES ROD @ 60"SHELF @ 66" linen drawers STAIR HALL MASTER BEDROOM CHANGING ROOM CLOSET CLOSETCLOSETCLOSET CLOSET FRANKIE'S BEDROOM EDIE'S BEDROOMCLOSET PATCH FLOOR AT DEMO'D CHIMNEY EXISTING TUB TO REMAIN NEW SINK AND TOILET. RECONNECT / REUSE EXISTING PLUMBING. 32X84 CASED OPENING 32X84 CASED OPENING 32X84 DOORCLOTHES ROD @ 60"SHELF @ 66"BATH linencabinet WALK-IN CLOSET REFINISH WOOD FLOOR REFINISH WOOD FLOOR REFINISH WOOD FLOOR REFINISH WOOD FLOOR REPAIR EXISTING GUTTER. REPAIR WATER DAMAGE AT FASCIA PATCH WALLS, FLOOR & CEILING AS REQUIRED & AS AS AFFECTED BY NEW WORK PATCH WALLS, FLOOR & CEILING AS REQUIRED & AS AS AFFECTED BY NEW WORK NEW CASED OPENING REPAIR OR REPLACE EXISTING GUARD RAIL, TYP. INFILL PROVIDE NEW 24" DEEP P.LAM. COUNTER & BACKSPLASH OVER WASHER/DRYER TILE WOOD FLOOR THRESHOLDTHRESHOLD THRESHOLDTILE TILE existing bench PATCH WALLS, FLOOR & CEILING AS REQUIRED & AS AS AFFECTED BY NEW WORK REFINISH WOOD FLOOR GENERAL NOTE: INSULATE EXISTING EXTERIOR WALLS, R-20 PROPOSED 2ND FLOOR PLAN Scale: 1/8" = 1'-0"A2 0 5 10 15 FT This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. JODY BARKER, A.I.A. | Architecture + Design, LLC 32 Willow Street Florence, Massachusetts 01062 cell: 617.216.5988 e: jodybarker.aia@gmail.com Proposed Renovations to 302 ELM STREET Northampton, Massachusetts 09 March 2017 DN PLAY ROOM ATTIC ATTIC STAIR HALL KITCHEN BATHOFFICE CLOSET CLOSET REFINISH WOOD FLOOR REFINISH WOOD FLOOR PATCH PLASTER & GWB AT WALLS & CEILING, TYP. PATCH PLASTER & GWB AT WALLS & CEILING, TYP. REFINISH WOOD FLOOR EXISTING TILE FLOOR NEW VCT FLOORING AT KITCHEN NEW UNDER COUNTER REF. IN PLACE OF DISH WASHER NEW 30"X84" DOOR IN EXIST. OPENING CHIMNEYEXISTING SKYLIGHTPATCH PLASTER & GWB AT WALLS & CEILING, TYP. PATCH PLASTER & GWB AT WALLS & CEILING, TYP. GENERAL NOTE: INSULATE EXISTING EXTERIOR WALLS, R-20 PROPOSED 3RD FLOOR PLAN Scale: 1/8" = 1'-0"A3 0 5 10 15 FT