VentMasterManualFINAL Vent Master
OWNER’S MANUAL
Read these instructions before you install or operate
the Orton Vent Master System
The Edward Orton Jr. Ceramic Foundation
PO Box 2760
Westerville, Ohio 43086 Phone: 614-895-2663
Fax: 614-895-5610
Website: www.ortonceramic.com
2
Congratulations on your purchase of
the Orton Vent Master System!
This manual covers the general use and installation of the Orton Vent
Master System. Refer to the installation instructions for more specific
details in installation.
CONTENTS
UNPACKING …….…………………………….….. 2
ITEMS YOU NEED TO INSTALL…………...….3
VENT MASTER INSTALLATION ……………… 4
- SIZE AND NUMBER OF HOLES ………. 4
- HOLES IN THE KILN FLOOR ………...… 5
- HOLES IN THE KILN LID …………..….… 6
- VENT MASTER ASSEMBLY………….……7
- TESTING THE VENT MASTER …………..8
VENT MASTER OPERATION …………..…….. 8
HELPFUL HINTS…………………………………..11
ABOUT FIRING…………...…………………….…13
TROUBLESHOOTING …………………….…….15
OPTIONAL PARTS……………………….……….16
WARRANTY ………………………………….…... 17
HISTORY OF ORTON…………………………….20
UNPACKING
Your Orton Vent Master System kit includes:
• Fan assembly (Blower Housing Package) with 6 ft power cord
• Collector cup with adjustable height foot
• High temperature gasket to seal collector cup to bottom or side
of kiln
• 3 foot length of 2” diameter high temperature black flex hose
• Two-2” hose clamps
• One-¼” drill bit
• One-3” stud
• Orton sample test cones
• Cones and Firing booklet
• Kiln Safety booklet
3
Items you will need to install your new Vent Master:
. a screwdriver
. an electric drill (if your kiln has a steel plate on the bottom)
. a vacuum cleaner
. duct tape (optional)
. a dryer vent kit – (containing flexible aluminum hose and 4” hose
clamp) available from hardware and home center stores
(Note: When selecting the dryer vent kit, be sure the vent flap is
lightweight enough to be blown open easily and the vent pipe is long
enough to go through your outside wall).
You have the option to install the Vent Master as a positive or negative
pressure system, meaning that you can install the Vent Master to push
the vent exhaust (positive pressure) out of the room or you can install the
Vent Master to pull the vent exhaust (negative pressure) out of the room.
For a Positive Pressure System: Dryer Vent Kit w/sufficient length of 4”
aluminum, dryer vent duct to exhaust through outside wall.
For a Negative Pressure System: Sufficient length of high temperature 2”
vacuum hose to allow blower assembly to be mounted adjacent to
exhaust opening in wall.
4
The Positive Pressure system will require the location of the blower
assembly near the kiln utilizing the 3 foot section of High temperature
black flex hose (can be cut to length but recommend that the blower
assembly be a minimum of 6 inches from the kiln) to connect the
collector cup to the blower assembly and utilizing 4 inch aluminum, dryer
vent duct to exhaust to the outside. (Do not use plastic dryer vent duct)
The Negative Pressure system will require the blower assembly to be
located near the room exhaust opening to the outside utilizing up to 25
feet of High temperature black flex hose to connect the collector cup to
the blower assembly. See your Vent Master dealer for additional High
temperature black flex hose.
NOTE: The Vent Master System is designed for use with
electric powered kilns and should NOT be used on a gas fired
kiln.
VENT MASTER INSTALLATION
1. DETERMINE NUMBER AND SIZE OF HOLES
Use the following charts to determine the appropriate number of holes
for your kiln. As a general rule, you should have one-¼” hole for every 4
cubic feet kiln volume.
Kiln volume is given in cubic feet. All other dimensions are given in
inches.
Kiln
Volume Multisided or Round Kilns Rectangular Kilns
#
Holes
(cu ft) sides diameter depth length width depth Total
1 - 2 8 17.5 12 12 12 18 1
2 - 4 8 17.5 27 18 18 18 1
4 - 6 8 17.5 31.5 20 20 20 2
10 23.5 18 - 24 30 20 24 2
6 - 8 10 23.5 27 24 24 24 2
8 - 10 10 23.5 31.5 22 16 44 3
10 - 12 12 28 27 - 31.5 24 24 36 3
12 - 14 12 28 36 4
Oval 25 x 27 37 4
5
CAUTIONARY NOTE: If Vent Master collection cup is to be
installed on the side of the kiln, please follow the
instructions regarding number of holes, but make certain
NOT to drill holes in the side of the kiln that will intersect the
heating elements. If further information is needed, please
contact Orton.
2. DETERMINE PLACEMENT OF HOLES IN KILN FLOOR
Use the diagram following to determine where to place the holes in
your kiln floor. Make certain that the holes are close enough to be
contained into the opening of the Vent Master collector cup, keep them
clustered together within about a 3 ½” diameter circle in the center of
the kiln floor. You may use the gasket as a template.
6
Preparing the Kiln for Vent Master Installation
Make sure your kiln is unplugged before beginning installation. If it is a
multiple ring design, you may wish to remove the top ring(s) to make it
easier to drill through the floor of the kiln.
Drilling Ventilation Holes in the Kiln Floor
If your floor is supported by a metal plate, use an electric
drill. For standard firebrick kiln floors or refractory fiber kilns, the drill bit
can be rotated by hand, OR, firmly support the floor of the kiln on a piece
of scrap wood and use an electric drill to slowly drill through the floor into
the wood. Precision and care are important. Vacuum out any dust that
gets in your kiln from drilling.
NOTE: Do not drill holes with the kiln installed above the
Orton Vent Master System - dust may damage the motor.
3. DETERMINE PLACEMENT OF HOLES IN KILN LID
Use the following diagram to determine where to place the holes in the lid of the kiln.
Drill the holes about 1" inside the edge of the firebrick. Be sure the holes open into
the firing chamber, not into the firebrick.
7
Drilling Holes in the Kiln Lid
You should drill the same size and number of holes for your kiln lid as you
did in the floor, though the spacing is different. If your kiln has an existing
hole in the lid, it will need to be closed. You can use refractory cement or
a refractory brick to block the hole.
Lid holes must be above the open firing chamber, not above the kiln wall,
in order to achieve proper air flow.
Vacuum out any brick dust that was generated during drilling. You are
now ready to install the Orton Vent Master System.
NOTE: The Vent Master System is specifically designed to
vent air to the outside, and should not be used for any other
purpose.
4. VENT MASTER ASSEMBLY
1. Determine # of holes needed and placement of holes
2. Drill holes
3. Install collector cup making certain that the holes are directly over the
top opening of the cup
4. Attach hoses with metal clamps and tighten
5. Maintain a distance of at least six inches from the blower housing and
the side of the kiln. Never place the blower housing under the kiln, doing
so would void the warranty
6. Plug in Vent Master
7. Test air flow
PLEASE ALSO SEE HELPFUL HINTS ABOUT INSTALLATION ON
PAGE 11
8
5. TESTING THE VENT MASTER
Use the match test, outlined below, to insure proper ventilation.
Testing for Proper Venting - the Flame Test
To test the operation of the Orton Vent Master System, turn on the vent.
Be sure the power to the kiln is off. Place a lighted match or lighter
directly over and level with one of the holes in the lid of the kiln.
The flame from the match or lighter should be gently pulled into the kiln
as a result of the draft, as illustrated below. If you are unsure of the
effect of the draft, observe the action of the flame away from the hole,
and then move it back over and level with the hole.
If the flame is not pulled into the kiln, the kiln is not venting properly. See
Troubleshooting, pg. 15. This test should be done regularly to be sure
that the Orton Vent Master System is operating correctly.
Flame is pulled into the kiln
VENT MASTER OPERATION
OPERATION
Turn Vent Master on using the in-line on-off switch, which is located on
the power cord. Close the lid on your kiln, plug the peepholes, and fire as
you normally would.
You can open any (one) peephole during firing to check the bending of
the cones and the progress of your firing, but the kiln lid and other
peepholes should be kept closed during the firing. In fact, if the lid is
propped or a peephole is left open, the Vent Master will not work properly
- loss of negative pressure will allow fumes to enter the room, and the
cool air drawn into the kiln may adversely affect your firing.
9
Vent Master pulls air into the kiln at the top, as air is drawn out of the kiln
at the bottom. See the diagram next page. This method causes the air
pressure inside the kiln to be slightly lower than outside of the kiln.
As a result of this negative pressure, air will be pulled into the kiln
through any hole or crack. This removes essentially 100% of the fumes
generated, providing:
1. the system is installed properly
2. the kiln is not excessively loaded with ware
3. heating rates are less than 150°C/hour for heavy loads
4. the kiln does not contain large gaps, holes or cracks
Extensive test firings using the Orton Vent Master were done for bisque
and glazed ware and no detectable odors were found. Reports from users
firing lusters and other odorous products have been very positive, with
responses delighted that the ventilation system could eliminate even
these very strong odors.
The design of the ventilation system includes a safety factor to handle
even more difficult problems; however, if odor does occur, an additional
small hole can be added/ opened in the floor only of the kiln.
LENGTH OF DUCTING
Up to 60 feet of ducting containing four 90° bends may be safely used
with no drop in static air flow at the duct exhaust point or a reduction in
draw at the kiln. Do not worry about straight vertical climbs. The
exhausted fumes will be warmer than room temperature, and will rise
naturally.
This following table should be used as a helpful guide in
determining the maximum length of 4” exhaust pipe
recommended for proper installation.
Maximum Length in feet Maximum Number of 90˚ Bends
100 0
90 1
80 2
70 3
60 4
FRESH MAKE-UP AIR
During firing, you must have a source of fresh air to replace the air
vented outdoors. The Orton Vent Master System fan discharges
approximately 60-80 cubic feet per minute. If needed, open a window or
leave a door slightly ajar for make-up air.
10
DURING COOLING
It is suggested that you leave the Orton Vent Master System switch in the
on position during cooling. This will permit the kiln to cool more quickly at
lower temperatures and give you access to your ware sooner.
HOW VENT MASTER WORKS
(SINGLE KILN)
(DUAL KILNS)
11
1. Holes drilled in floor of the kiln allow fumes to be pulled out of the kiln,
while holes in lid allow fresh air to enter.
2. Kiln lid and peepholes remain closed throughout the firing.
3. Negative pressure in the firing chamber insures complete fume
removal.
4. Fumes are diluted and exhausted to the outside through ducting.
NOTE: An expansion kit should be purchased
to vent:
- Two kilns with a combined firing volume not exceeding
20 cubic feet
- Oval kilns exceeding 12 cubic feet but not exceeding
20 cubic feet
HELPFUL HINTS
ABOUT INSTALLATION
High temperature black flex Collector cup with gasket,
hose and clamp adjustable height foot, stud,
coupling and wing nut
Gasket installed on collector cup High temperature black flex
(use tape to keep in place) hose attached to collector
cup
12
High temperature black flex Drill holes in kiln floor with
hose attachment to blower drill bit provided
housing
Drill holes in kiln lid Under kiln mount with height
with drill bit provided adjustment
Under kiln mount with no Side kiln mount of collector cup
height adjustment
13
Optional wall mounting Complete wall mount
typical set up
Typical floor mount set up
ABOUT FIRING:
TEST FIRING
You have been supplied with Orton’s #06 Self-Supporting cones to be
used to help evaluate the firing performance of your venting system.
These cones are made in compacts (joined together at a parting line) and
must be separated prior to use. Please refer to our website for detailed
information on the properties, uses and behavior or Orton Pyrometric
cones.
Following the installation of the Vent Master, a test firing using the self-
supporting 06 cones supplied, should be made to determine the overall
firing performance of the kiln. Place one cone on different shelves near
the center of the shelf and also near the edge. Per the firing instructions
from the kiln manufacturer, make a cone 06 firing. After the firing,
examine and compare the bend of each cone by location. Differences in
bend will show the magnitude of any hot or cold spots in the kiln.
14
Typically, the Vent Master should minimize variations and the cones
should deform to near the same position. Use of witness cones placed
on each shelf of the kiln during every firing will confirm that your ware
was fired properly and advise you of any changes in the firing
performance of your kiln(s) before significant problems develop.
MAXIMIZE YOUR KILN PERFORMANCE USING QUALITY ORTON PRODUCTS
Vent Master
Downdraft Venting
Downdraft venting of electric kilns was invented by Orton. It is the only
venting method to improve firing conditions in the kiln while removing
essentially all fumes. It works by continuously pulling a small amount of
gas out of the kiln. This gas is mixed with room air and exhausted
outside. Vent Master produces many good results:
• Removes fumes during firing
• Improves firing: true colors, better carbon burnout
• Extends life of heating elements
• Improves temperature uniformity
• Easy to install
• Eliminates propping kiln lid
• Inexpensive to operate
• Can reduce kiln cool-down by 4-10 hours
• Use for any type of kiln
Orton Pyrometric Cones
Monitor your firing with Orton Cones
• Cones measure the amount of heat available
• Self-supporting cones don’t need plaques
• Determine when firing is complete
• Measure temperature uniformity in kiln
• Use to check performance of electronic controllers
• Use to check shut-off of Kiln Sitter™
• Use to compare firings
Autofire™ Controllers
Take control of your kiln and your time.
Controllers are reliable products developed by Orton to improve
temperature uniformity while providing more accurate control of the
firing. Existing kilns can be retrofitted for operation with Orton Autofire™
controllers.
15
Compare Autofire™ Features:
• Better kiln control
• Easy-to-use preset cone firing programs
• 3-touch firing to a cone number
• 4 user programs with 10 ramps each
• Use type K, N or S thermocouples
• Programmable Vent Master control
• Hand-held programming
• ControlMaster software to interface with computer
• Diagnostics for determining source of problem
• Computer support and 1 year warranty
• Monitor up to 16 kilns from a computer
TROUBLESHOOTING THE ORTON VENT MASTER
Problem: Smell or odor coming from kiln
Cause: Insufficient airflow
Solution: Check that collector cup is positioned under exhaust holes and
the holes are unobstructed. Make sure bottom shelf is supported 1”
above the floor of the kiln to allow for proper circulation
Cause: Wrong number of holes drilled in bottom of kiln, incorrect size
holes, or holes drilled in wrong location.
Solution: Refer to installation step number 1 on page 4 of this manual
Cause: Kiln is not sealed sufficiently
Solution: Close all peep holes and seal, where possible, any cracks or
gaps around the kiln
Cause: Holes in exhaust hose or duct
Solution: Repair or replace duct or hose
Cause: Obstruction in exhaust ductwork
Solution: Clear holes and hoses of any obstructions. Make sure flapper
on dryer duct is not stuck
Cause: Kiln loaded with too much ware
Solution: Reduce load
Problem: Kiln not venting at all
Cause: No power
Solution: Make sure vent is plugged in and switch is “on”. Check circuit
breaker in electrical panel
16
Cause: Motor or wiring burnt out
Solution: Replace motor, see Warranty for details
Problem: Kiln slow to reach target temperature
Cause: Kiln is not adequately sealed
Solution: Plug or repair any cracks, holes or gaps in the kiln
Cause: Heating elements worn out
Solution: Replace heating elements
Cause: Too many holes or holes drilled too large
Solution: Refer to installation step 1 in this manual
For additional help, refer to our website
www.ortonceramic.com . Look in the Resources section and
you will find our frequently asked questions page.
Optional Parts:
Expansion Kit (For Venting Two Kilns) Includes:
Complete Collector Cup Assembly
3’ Length High Temperature Black Flex Hose
(2) 2” Hose Clamps
Extender Kit Includes:
2” Coupling
3’ Length High Temperature Black Flex Hose
(2) 2” Hose Clamps
For Support or Questions, Contact us at:
info@ortonceramic.com
or call or fax:
Phone: 614-895-2663
Fax: 614-895-5610
THANK YOU FOR YOUR PURCHASE!
17
LIMITED WARRANTY
This limited warranty is given only to the immediate purchaser (“Buyer”)
of the Vent Master System (“Vent Master System”). This limited warranty
is not transferable. The Edward Orton Jr. Ceramic Foundation (“Orton”)
warrants the blower housing and electric motor contained within the Vent
Master System (“Warranted Components”) to be in good working order
under normal operating conditions for a period of one (1) year from the
date of purchase. Should the Warranted Components fail to be in good
working order at any time during the stated one (1) year period, Orton
will, at its option, repair or replace the Warranted Components as set
forth below. The liability of Orton is limited to replacement and/or repair
at its factory of the Warranted Components that do not remain in good
working order. Repair parts or replacement products will be furnished on
an exchange basis and will be either reconditioned or new. All replaced
parts and products become the property of Orton. Following receipt of
notice from Buyer of a valid warranty claim and the Vent Master System
containing the Warranted Components, Orton will perform its obligations
under this limited warranty within 10 business days.
Limited warranty service may be obtained by delivering the Vent Master
System during the warranty period to your Orton Vent Master System
supplier or to The Edward Orton Jr. Ceramic Foundation, 6991 Old 3C
Highway, Westerville OH 43082 and providing written proof of purchase
and description of the defect or problem. Buyer must insure the shipment
of the Vent Master System or assume the risk of loss or damage in
transit, prepay shipping charges to the service location, and use the
original shipping container or equivalent. Buyer will be responsible for
shipping and handling changes in excess of US $50.00 incurred by Orton
in returning the Vent Master System to the buyer after completion of
limited warranty service.
This warranty does not apply to any damage resulting from:
1. Operation beyond electrical rating.
2. External sources including, but not limited to, chemicals, heat abuse
and improper care.
3. Improper or inadequate maintenance by Buyer.
4. Parts or equipment not supplied by Orton.
5. Unauthorized modification or misuse.
6. Operation outside environmental specifications.
7. Improper installation.
8. Firing of kiln with Vent Master System installed but not operating
during firing cycle.
9. Overfiring (melting of materials being fired) regardless of the cause of
the firing.
18
Warranted Components returned for service where no warranted defect
is found will be subject to service, and shipping and handling fees.
If the Warranted Components are not in good working order as warranted
above, Buyer’s sole remedy shall be repair or replacement of the
Warranted Components as provided above. To the extent permitted by
law, ALL EXPRESS AND IMPLIED WARRANTIES FOR THE WARRANTED
COMPONENTS INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE ONE YEAR
WARRANTY PERIOD COMMENCING ON THE DATE OF PURCHASE, AND NO
OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED, WILL APPLY TO
THIS PERIOD. To the extent permitted by law, ORTON’S LIABILITY AND
BUYER’S SOLE REMEDY IS LIMITED SOLELY AND EXCLUSIVELY TO
REPAIR OR REPLACEMENT AS SET FORTH HEREIN. ORTON SHALL NOT
BE LIABLE FOR, AND BUYER’S REMEDY SHALL NOT INCLUDE ANY
INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES OF ANY KIND
WHATSOEVER, WHETHER A CLAIM IS BASED UPON A THEORY OF
CONTRACT, NEGLIGENCE OR TORT. Buyer shall determine suitability of
the Vent Master System for the intended use and assume all risk and
liability therewith. Some states do not allow this exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from State to State.
The above limitation of liability does not apply in the event that any
Warranted Components are determined by a court of competent
jurisdiction to be defective and to have directly caused bodily injury,
death or property damage; provided that in no event shall Orton's liability
exceed the greater of $1000.00 or the purchase price of the specific
Vent Master System that caused such damage.
Service may also be obtained on Warranted Components no longer under
warranty by returning the Vent Master System prepaid to Orton with a
brief description of the problem and Buyer’s name and contact
information. Buyer will be contacted with an estimate of service charges
before any work is performed.
19
Customer Satisfaction Policy
If, for any reason, you are not completely satisfied with the
performance of the Orton Vent Master System or the conditions of this
warranty, return the Vent Master System in good working condition,
transportation and insurance prepaid, within 30 days of purchase date
to your Orton Vent Master System supplier or to The Edward Orton Jr.
Ceramic Foundation, 6991 Old 3C Highway, Westerville, OH 43082
and your purchase price will be refunded. Prior to returning your Vent
Master System, contact Orton for an authorization number and include
with your shipment. For Vent Master Systems ordered in error, a
restocking charge will apply.
IMPORTANT NOTE: RETAIN PACKING SLIP OR COPY
OF SALES RECEIPT FOR WARRANTY PURPOSES
20
THE HISTORY OF ORTON PRODUCTS
Helping the Ceramic Community grow since 1896.
In 1896, Professor Edward Orton Jr. began the Standard
Pyrometric Cone Company, manufacturing pyrometric cones
at The Ohio State University, Columbus, Ohio USA. These
cones quickly became the standard by which firings were
monitored and controlled, as they often are today.
Because of his interest and commitment to advancing the
ceramic arts and industries and his desire to have high
quality pyrometric cones always available for monitoring and
control of the firing process, Orton left his company as a
nonprofit trust. Income is used to develop and disseminate
technical information that helps solve firing and other
processing problems. Orton's website provides information
and technical assistance on customer-specific firing
problems, as well as publications, technical notes and other
related information.