Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
25 -012 Foundation Yell Labato sig
01/15/2017Top of finish floor to be flush with top of house floor. C-C-2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/1463 15⁄16" for 5⁄8" Bolts11⁄2" for 3⁄4" Bolts 43⁄8" 3" 51⁄4" For 5⁄8" Bolts For 3⁄4" BoltsConfiguration of all other CB sizes LCB MATERIAL: See table FINISH: LCB, CB44, CB46, CB48, CB66, CB68, CB610—galvanized; all other CB—Simpson Strong-Tie® gray paint or HDG. Some models available in HDG or stainless steel INSTALLATION: • Use all specified fasteners. See General Notes. • For full loads, minimum side cover required is 3" for CB, 2" for LCB. • Install all models with bottom of base plate flush with concrete. • Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). OPTIONS: • LCB and CB are available in rough size. Other sizes available for CB specify W1 and W2 dimensions. Consult Simpson Strong-Tie for bolt sizes and allowable loads. CODES: See page 12 for Code Reference Key Chart. 3" Min.SideCover 3" Min.SideCover For 5⁄8" Bolts For 3⁄4" BoltsCB9(CB5, CB7 similar)for Glulam Column CB44 (CB46, CB48, CB64, CB66, CB68, CB86, CB88, CB610 similar) 1. Loads may not be increaed for short-term loading.2. Concrete shall have a minimum compressive strength, f'c = 2500 psi.3. LCB products may be installed with either bolts OR nails (not both) to achieve table loads.4. Multiply Seismic and Wind ASD load values by 1.4 or 1.6 respectively to obtain LRFD capacities.5. In accordance with IBC Section 1613.1, detached one- and two-family dwellings in Seismic Design Category (SDC) C may use “Wind and SDC A&B” allowable loads. 6. Download capacity shall be based on either the wood post design or concrete design calculated per code. See pages 245-246 for common post allowable loads.7. Designer is responsible for concrete design. Minimum foundation dimensions are for anchorage only.8. Loads must not be increased by short-term loading.9. NAILS: 16d = 0.162" dia. x 3 1⁄2" long. See pages 22-23 for other nail sizes and information. These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details. Model No. Nominal Column Size Dimensions (in.)Column Fasteners Allowable Loads DF/SP/SPF/HF (160) Code Ref. Wind and SDC A&B SDC C-F W1 W2 Nails Machine Bolts Non-Cracked Cracked Non-Cracked Cracked Qty.Dia. (in.)Uplift Uplift Uplift Uplift LCB44 4x4 3 9⁄16 3 1⁄2 12-16d 2 1⁄2 1170 820 985 690 I28, F1, L27 CB44 4x4 3 9⁄16 3 9⁄16 NA 2 5⁄8 6710 4700 5640 3945 LCB46 4x6 3 9⁄16 5 1⁄2 12-16d 2 1⁄2 1170 820 985 690 CB46 4x6 3 9⁄16 5 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 CB48 4x8 3 9⁄16 7 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 CB5-4.5 GLULAM 4 1⁄2 5 1⁄8 NA 2 5⁄8 6710 4700 5640 3945 170CB5-6 GLULAM 6 5 1⁄8 NA 2 5⁄8 6710 4700 5640 3945 LCB66 6x6 5 1⁄2 5 1⁄2 12-16d 2 1⁄2 1170 820 985 690 I28, F1, L27CB666x65 1⁄2 5 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 CB6-7 6x 5 1⁄2 7 NA 2 5⁄8 6710 4700 5640 3945 170 CB68 6x8 5 1⁄2 7 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 I28, F1, L27 CB610 6x10 5 1⁄2 9 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 170 CB612 6x12 5 1⁄2 11 1⁄2 NA 2 5⁄8 6710 4700 5640 3945 CB71/8 -4 PSL 7 1⁄8 3 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB71/8 -6 PSL 7 1⁄8 5 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB71/8 -7 PSL 7 1⁄8 7 NA 2 3⁄4 6710 4700 5640 3945 CB7-6 GLULAM 6 6 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB7-7.5 GLULAM 7 1⁄2 6 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB7-9 GLULAM 9 6 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB7-10.5 GLULAM 10 1⁄2 6 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB86 8x6 7 1⁄2 5 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB88 8x8 7 1⁄2 7 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB810 8x10 7 1⁄2 9 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB812 8x12 7 1⁄2 11 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB9-6 GLULAM 6 8 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB9-7.5 GLULAM 7 1⁄2 8 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB9-9 GLULAM 9 8 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB9-10.5 GLULAM 10 1⁄2 8 3⁄4 NA 2 3⁄4 6710 4700 5640 3945 CB1010 10x10 9 1⁄2 9 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB1012 10x12 9 1⁄2 11 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 CB1212 12x12 11 1⁄2 11 1⁄2 NA 2 3⁄4 6710 4700 5640 3945 LCB/CB Column Bases Caps & Bases Caps & Basespage 63