Loading...
109 Main Street, Northampton balencing reportPROJECT # 282 FOMER ROAD SOUTHAMPTON, MA 01073 #BB977252T T.A.B.B. CERTIFIED DATE: 3/15/2017 00317 PROJECT:109 MAIN STREET, 2ND FLOOR LOCATION: NORTHAMPTON. MA ARCHITECT:THOMAS DOUGLAS ARCHITECTS, INC. ENGINEER: CUSTOMER: M.J. MORAN, INC. 413·527·1682 TABLE OF CONTENTS SHEET PAGE(S) COVER SHEET 1 TOC 2 ABBREVIATIONS 3 ERV-1 DATA 4 ERV-1 AIR OUTLET 5 RTU-4 DATA 6 RTU-4 AIR OUTLET 7 RTU-5 DATA 8 RTU-5 AIR OUTLET 9 EXHAUST DATA 10 EXHAUST AIR INLET 11 PROJECT NAME ENTER NAME ON COVER SHEET PROJECT №PRELIMINARY DATE 2 OF 11 ABBREVIATIONS AHU AIR HANDLING UNIT LPS LOW PRESSURE STEAM AC or ACU AIR CONDITIONER UNIT LT LIGHT TROFFER ACCU AIR COOLED CONDENSING UNIT LWG LOW WALL GRILLE AMP AMPERAGE LWT LEAVING WATER TEMPERATURE AVG AVERAGE MAU / MUA MAKE UP AIR UNIT A.D.AIR DENSITY MBH 1,000 BTU'S PER HOUR BHP BRAKE HORSEPOWER N/A NOT ACCESSIBLE CB CIRCUIT BREAKER N.I.NOT INSTALLED CD CEILING DIFFUSER N.L.NOT LISTED CFM CUBIC FEET PER MINUTE NA NOT APPLICABLE CE CEILING EXHAUST N.Z.NOZZLE CH CHILLER O.D.OUTSIDE DIAMETER CHW CHILLED WATER O/A MIN OUTDOOR AIR MINIMUM CR CEILING RETURN OAT OUTSIDE AIR TEMPERATURE CP CIRCULATING PUMP PF POWER FACTOR CC COOLING COIL PHC PRE-HEAT COIL CT COOLING TOWER PH PHASE CW CONDENSER WATER PMP CIRCULATING PUMP DB DRY BULB PSI POUNDS PER SQUARE INCH. DD DIRECT DRIVE RA RETURN AIR DIA DIAMETER RF RETURN FAN DP DIFFERENTIAL PRESSURE R.G.RETURN GRILLE EAT ENTERING AIR TEMPERATURE RHC RE-HEAT COIL EDC ELECTRIC DUCT COIL RPM REVOLUTIONS PER MINUTE EDH ELECTRIC DUCT HEATER RTU ROOF TOP UNIT EF EXHAUST FAN RVA ROTATING VANE ANEMOMETER EMCS ENERGY MGMT. CONTROL SYSTEM SA SUPPLY AIR EWT ENTERING WATER TEMPERATURE SAT SUPPLY AIR TEMPERATURE FCU FAN COIL UNIT S.D.SUPPLY DIFFUSER FH FUME HOOD SEF SMOKE EXHAUST FAN FG FLOOR GRILLE SF (AIR)SUPPLY FAN FE FLOOR EXHAUST OR RETURN SF (ELEC.)SERVICE FACTOR FLA FULL LOAD AMPERAGE SHC STEAM HEATING COIL FPB FAN POWERED BOX S.P."W.C."STATIC PRESSURE IN WATER COLUMN FPT FAN POWERED TERMINAL S.W.E.SIDEWALL EXHAUST FPM FEET PER MINUTE S.W.R.SIDEWALL RETURN FS FLOOR SUPPLY S.W.S.SIDEWALL SUPPLY FSR FLOOR SUPPLY REGISTER TAB TESTING ADJUSTING & BALANCING FT HD FEET OF HEAD TSP TOTAL STATIC PRESSURE FTU FAN TERMINAL UNIT UH UNIT HEATER GPM GALLONS PER MINUTE V VOLTS HC HEATING COIL VEL VELGRID HEPA HIGH-EFFICIENCY PARTICLE ARRESTANCE VAV VARIABLE AIR VOLUME HF HEPA FILTER VD VOLUME DAMPER HOA HAND / OFF / AUTO SWITCH VFD VARIABLE FREQUENCY DRIVE HP HORSEPOWER VP VELOCITY PRESSURE HPS HIGH PRESSURE STEAM VPT VELOCITY PRESSURE TRAVERSE HRC HEAT RECOVERY COIL W WATTS HVAC HEATING, VENTILATION & AIR CONDITIONING WB WEB BULB HWR HOT WATER RETURN W.D.WATER DENSITY HWS HOT WATER SUPPLY W.G.WATER GAUGE HX HEAT EXCHANGER F FAHRENHEIT ID INSIDE DIAMETER ΔP DIFFERENTIAL PRESSURE LAT LEAVING AIR TEMPERATURE ΔT DIFFERENTIAL TEMPERATURE LD LINEAR DIFFUSER Ø ROUND 3 OF 11 ERV TEST REPORT PROJECT NAME PROJECT № DATE 3/13/2017 UNIT INFORMATION DESIGNATION №ERV-1 MANUFACTURER RENEW AIRE LOCATION IN-LINE MODEL №EV300 SERVICE CONFERENCE SERIAL №L160855R SUPPLY EXHAUST MOTOR INFORMATION MOTOR INFORMATION MANUFACTURER FASCO MANUFACTURER N/A CATALOG №71902996 CATALOG №N/A HORSEPOWER 1/4 HORSEPOWER N/A RPM 1550 RPM N/A SERVICE FACTOR N.L.SERVICE FACTOR N/A POWER FACTOR N.L.POWER FACTOR N/A EFFICIENCY N.L.EFFICIENCY N/A FRAME N.L.FRAME N/A DRIVE INFORMATION DRIVE INFORMATION MOTOR SHEAVE / BORE DIRECT DRIVE MOTOR SHEAVE / BORE DIRECT DRIVE FAN PULLEY / BORE DIRECT DRIVE FAN PULLEY / BORE DIRECT DRIVE BELTS - QTY / SIZE DIRECT DRIVE BELTS - QTY / SIZE DIRECT DRIVE SHEAVE POSITION DIRECT DRIVE SHEAVE POSITION DIRECT DRIVE CENTER TO CENTER DIRECT DRIVE CENTER TO CENTER DIRECT DRIVE TEST INFORMATION TEST INFORMATION DESIGN CFM 300 DESIGN CFM 280 CONNECTED CFM 300 CONNECTED CFM 280 MEASURED CFM 376 MEASURED CFM 272 DESIGN E.S.P..25''DESIGN E.S.P..25'' DELIVERED E.S.P..25''DELIVERED E.S.P..22'' PLENUM S.P.-.23''PLENUM S.P.-.16'' DISCHARGE S.P..02''DISCHARGE S.P..06'' DESIGN FAN RPM DIRECT DRIVE DESIGN FAN RPM N/A ACTUAL FAN RPM SINGLE SPEED ACTUAL FAN RPM N/A VOLTAGE-PHASE 115-1 VOLTAGE-PHASE N/A MOTOR AMPS RATED 2.9 MOTOR AMPS RATED N/A MEASURED AMPERAGE 2.7 MEASURED AMPERAGE N/A VFD SETTING N/A VFD SETTING N/A S.P.C.P.N/A UNIT HAS ONE MOTOR THAT OPERATES BOTH FANS. NOTE: 109 MAIN STREET, 2ND FLOOR 00317 4 OF 11 AIR OUTLET TEST REPORT PROJECT NAME PROJECT № DATE №OUTLET AREA K (AK)NOTE SIZE FPM CFM FPM CFM ERV-1 SUPPLY CONFERENCE ROOM 1 24X12 100 124 CONFERENCE ROOM 2 24X12 100 116 3 24X12 100 136 300 376 EXHAUST CONFERENCE ROOM 1 38X6 280 272 109 MAIN STREET, 2ND FLOOR 00317 3/13/2017 DESIGN ACTUAL 5 OF 11 AHU TEST REPORT PROJECT NAME PROJECT № DATE 3/15/2017 UNIT INFORMATION DESIGNATION №RTU-4 MANUFACTURER TRANE LOCATION ROOF MODEL №YHC043A3RMA1KD000A SERVICE OFFICE AREA SERIAL №835101307L MOTOR INFORMATION DRIVE INFORMATION MANUFACTURER G.E. MOTORS MOTOR SHEAVE / BORE VL34 X 5/8" CATALOG №N/A FAN PULLEY / BORE AK41 X 3/4" HORSEPOWER 1 BELTS - QTY / SIZE 1 - AX26 RPM 1725 SHEAVE POSITION OPEN SERVICE FACTOR 1.5 CENTER TO CENTER 8.0'' POWER FACTOR N.L. EFFICIENCY N.L. FRAME 56 TEST INFORMATION DESIGN CFM 1,600 CONNECTED CFM 1,750 MEASURED CFM 2,250 DESIGN T.S.P.N.L. DELIVERED T.S.P..87''OUTDOOR AIR SUCTION S.P.-.69''DESIGN CFM 400 DISCHARGE S.P..18''MEASURED CFM 404 DESIGN FAN RPM N.L.CONTROL POSITION POT. ACTUAL FAN RPM 1019 VOLTAGE-PHASE 230-3 DUCT SIZE 27X11 MEASURED VOLTAGE 216/220/218 AREA 2.06' MOTOR AMPS RATED 5 FPM 196 MEASURED AMPERAGE 3.2/3.2/3.0 DESIGN BHP N/A MEASURED BHP N/A VFD SETTING N/A S.P.C.P.N/A 109 MAIN STREET, 2ND FLOOR 00317 6 OF 11 AIR OUTLET TEST REPORT PROJECT NAME PROJECT № DATE №OUTLET AREA K (AK)NOTE SIZE FPM CFM FPM CFM RTU-4 ROOM 5 1 4' LIN 150 198 ROOM 5 2 4' LIN 150 190 ROOM 6 3 4' LIN 150 205 ROOM 7 4 4' LIN 150 198 ROOM 8 5 4' LIN 150 200 ROOM 9 6 4' LIN 150 198 ROOM 10 7 4' LIN 150 200 OFFICE 8 12X12 100 133 OPEN OFFICE 9 12X12 300 354 OFFICE 16 10 12X12 150 196 OFFICE 17 11 12X12 150 178 1,750 2,250 109 MAIN STREET, 2ND FLOOR 00317 3/13/2017 DESIGN ACTUAL 7 OF 11 AHU TEST REPORT PROJECT NAME PROJECT № DATE 3/15/2017 UNIT INFORMATION DESIGNATION №RTU-5 MANUFACTURER TRANE LOCATION ROOF MODEL №YHC063A3RMA006N SERVICE OFFICE AREA SERIAL №835101517 MOTOR INFORMATION DRIVE INFORMATION MANUFACTURER G.E. MOTORS MOTOR SHEAVE / BORE VL34 X 5/8" CATALOG №N/A FAN PULLEY / BORE AK41 X 3/4" HORSEPOWER 1 BELTS - QTY / SIZE 1 - AX26 RPM 1725 SHEAVE POSITION 50% SERVICE FACTOR 1.5 CENTER TO CENTER 8.0'' POWER FACTOR N.L. EFFICIENCY N.L. FRAME 56 TEST INFORMATION DESIGN CFM 2,000 CONNECTED CFM 2,845 MEASURED CFM 2,866 DESIGN T.S.P.N.L. DELIVERED T.S.P.1.03''OUTDOOR AIR SUCTION S.P.-.82''DESIGN CFM 400 DISCHARGE S.P..21''MEASURED CFM 419 DESIGN FAN RPM N.L.CONTROL POSITION POT. ACTUAL FAN RPM 1144 VOLTAGE-PHASE 230-3 DUCT SIZE 27X11 MEASURED VOLTAGE 222/226/213 AREA 2.06' MOTOR AMPS RATED 5 FPM 203 MEASURED AMPERAGE 4.4/4.6/4.4 DESIGN BHP N/A MEASURED BHP N/A VFD SETTING N/A S.P.C.P.N/A 109 MAIN STREET, 2ND FLOOR 00317 8 OF 11 AIR OUTLET TEST REPORT PROJECT NAME PROJECT № DATE №OUTLET AREA K (AK)NOTE SIZE FPM CFM FPM CFM RTU-5 ROOM 4 1 4'LIN 150 165 ROOM 3 2 4'LIN 150 160 ROOM 2 3 4'LIN 200 214 ROOM 1 4 4'LIN 200 217 SECRETARY 5 9X9 300 290 WAITING 6 12X12 400 373 ROOM 11 7 4'LIN 180 190 ROOM 12 8 4'LIN 180 168 ROOM 13 9 4'LIN 180 178 KITCHEN AREA 10 12X12 250 255 KITCHEN AREA 11 12X12 250 258 WOMENS 12 9X9 180 172 TOILET 13 9X9 75 79 MENS 14 9X9 150 147 2,845 2,866 109 MAIN STREET, 2ND FLOOR 00317 3/15/2017 DESIGN ACTUAL 9 OF 11 EXHAUST FAN TEST REPORT PROJECT NAME PROJECT № DATE 3/15/2017 DESIGNATION №EF-2 EF-3 EXISTING EF LOCATION ROOF ROOF ROOF SERVICE C.O.KITCHEN/C.O.TOILETS MANUFACTURER S & P S & P NO TAG MODEL №SDB08ML1S SDB08ML1S NO TAG SERIAL №SN616287-1 SN616287-1 NO TAG MANUFACTURER MARATHON MARATHON EMERSON CATALOG №N/A N/A 839 HORSEPOWER 1/4 1/4 1/6 RPM 1725 1725 1725 SERVICE FACTOR 1.15 1.15 1.35 POWER FACTOR N.L.N.L.N.L. EFFICIENCY N.L.N.L.N.L. FRAME 48Y 48Y N.L. MOTOR SHEAVE / BORE VP44 X 1/2"VP44 X 1/2"VL25 X 1/2" FAN PULLEY / BORE AK41 X 5/8"AK41 X 5/8"5" X 5/8" BELTS - QTY / SIZE 1 - 4L210 1 - 4L210 1 - 3L210 SHEAVE POSITION OPEN 50%50% CENTER TO CENTER 5 1/2"5"5" DESIGN TOTAL CFM 400 400 450 CONNECTED CFM 400 400 450 DELIVERED CFM 432 397 461 DESIGN T.S.P..5''.5''N/A DELIVERED T.S.P..04''.39''.15'' DESIGN FAN RPM 1700 1700 N/A MEASURED RPM 1251 1630 791 VOLTAGE-PHASE 115-1 115-1 115-1 AMPERAGE RATED 5.1 5.1 3.5 MEASURED AMPERAGE 4.4 4.7 3.2 VFD SETTING N/A N/A N/A 109 MAIN STREET, 2ND FLOOR 00317 UNIT INFORMATION NOTES: MOTOR INFORMATION DRIVE INFORMATION TEST INFORMATION 10 OF 11 AIR OUTLET TEST REPORT PROJECT NAME PROJECT № DATE №OUTLET AREA K (AK)NOTE SIZE FPM CFM FPM CFM EF-2 C.O. FAN 1 14X14 1.361 0.8 1.09 367 400 397 432 EF-3 KITCHEN FAN C.O. FAN 1 14X8 0.778 1 0.78 257 200 267 208 EF-3 KITCHEN FAN 2 CEILING FAN 200 189 400 397 EXISTING FAN WOMENS 1 8X6 150 156 TOILET 2 8X6 75 79 MENS 3 8X6 150 150 JANITOR 4 8X4 75 76 450 461 109 MAIN STREET, 2ND FLOOR 00317 3/15/2017 DESIGN ACTUAL 11 OF 11