Loading...
107 Vernon St approved 2018-03-13DRAWN BYNelson GeisRE-ISSUE3/7/2018ISSUE2/18/2018CLIENTLadd107 Vernon StreetNorthampton, MA 01060 Keiter Builders35 Main StreetFlorence, MA 01062Tel: 413-586-8600 PROJECT107 Vernon Garage0101 A A-04 1 Site Plan Scale: 1"= 20'-0" Old Garage Outline 20'-6" x 20'-6" New Garage on same foundation corner 10'-0" 6'-0" Existing House107 Vernon Street New Garage 22'-0" x 24'-0" N DRAWN BYNelson GeisRE-ISSUE3/7/2018ISSUE2/18/2018CLIENTLadd107 Vernon StreetNorthampton, MA 01060 Keiter Builders35 Main StreetFlorence, MA 01062Tel: 413-586-8600 PROJECT107 Vernon Garage0202 ADESCRIPTION Plan DRAWN BYNelson GeisRE-ISSUE3/7/2018ISSUE2/18/2018CLIENTLadd107 Vernon StreetNorthampton, MA 01060 Keiter Builders35 Main StreetFlorence, MA 01062Tel: 413-586-8600 PROJECT107 Vernon Garage0303 A A-02 1 Plan Scale: 1/4" = 1'-0"A-02 2 Second Floor Plan Scale: 1/4" = 1'-0"A-02 1 Plan Scale: 1/4" = 1'-0"A-02 2 Second Floor Plan Scale: 1/4" = 1'-0" A-02 4 Section Scale: 1/4" = 1'-0"A-02 3 Section Scale: 1/4" = 1'-0"DESCRIPTIONPlan24'-2 1/4"20'-0"9'-0"8'-0"9'-0"7'-0"8'-0"9'-8"20'-0"7'-0"7'-1/2"3 12 12 8 22'-0"24'-0"16'-0" DRAWN BYNelson GeisRE-ISSUE3/7/2018ISSUE2/18/2018CLIENTLadd107 Vernon StreetNorthampton, MA 01060 Keiter Builders35 Main StreetFlorence, MA 01062Tel: 413-586-8600 PROJECT107 Vernon Garage0404 A A-04 3 South Elevation Scale: 1/4" = 1'-0" A-04 1 East Elevation Scale: 1/4" = 1'-0"A-04 2 North Elevation Scale: 1/4" = 1'-0" A-04 4 West Elevation Scale: 1/4" = 1'-0"20'-0"8'-0"9'-0"8'-0"9'-0"20'-0"4'-0"4'-0" 0.03kips/ft0.03kips/ft0.03kips/ft0.03kips/ft0.03kips/ft0.03kips/ft0.03kips/ft0.03kips/ftCONTINUOUS HEADER2ND FLOOR STRUCTURESHIPPING INFORMATION:DESIGNED BY: Doug HodginsJOB: Keiter/LaddKeiter Builders/Ladd GaraWest Hatfield Ma.21 West St.rk Miles Inc.Scale: 3/8" = 1'NOTES:SHEET NUMBER: 11st walls LAYOUTFINALN/AN/AISSUE:DATE:N/AN/A03/07/18DESCRIPTION:FINALN/AN/A107 Vernon St Northampton DESIGN ASSUMPTIONS ==================== Loads: T/C Live: 40 psf B/C Live: 0 psf T/C Dead: 10 psf B/C Dead: 0 psf Load Case: Live Deflection Criteria: L/360 Live L/240 Total Building Code: IBC/IRC (Allowable Stress De Design assumes continuous lateral bracing for both edges.0.13kips/ft0.10kips/ft0.10kips/ft0.10kips/ft0.10kips/ft0.07kips/ft0.07kips/ft0.07kips/ft0.07kips/ft0.13kips/ft0.13kips/ft0.19kips/ft0.19kips/ft0.19kips/ft0.07kips/ft0.07kips/ft0.13kips/ft0.19kips/ft0.19kips/ft0.85kips2.31kips0.85kips2.31kips0.83kips2.31kips0.83kips2.31kips0.31kips0.82kips0.31kips0.82kips0.27kips/ft0.13kips/ft0.15kips/ft0.15kips/ft0.65kips/ft0.57kips/ft0.68kips/ft0.57kips/ft0.07kips/ft0.07kips/ft0.04kips/ft0.19kips/ft0.19kips/ft0.04kips/ft0.19kips/ft0.72kips/ft0.63kips/ft0.76kips/ft0.83kips2.31kips0.83kips2.31kips1.16kips2.47kips1.16kips2.47kips1.04kips0.29kips0.31kips0.82kips0.31kips0.82kips1.04kips0.29kipsA 1 0" ocA 2 0" ocA 3 0" ocB 10 plyB 20 ply ROOF STRUCTURESHIPPING INFORMATION:DESIGNED BY: Doug HodginsJOB: Keiter/LaddKeiter Builders/Ladd GaraWest Hatfield Ma.21 West St.rk Miles Inc.Scale: 3/8" = 1'NOTES:SHEET NUMBER: 12nd walls LAYOUTFINALN/AN/AISSUE:DATE:N/AN/A03/07/18DESCRIPTION:FINALN/AN/A107 Vernon St Northampton DESIGN ASSUMPTIONS ==================== Loads: T/C Live: 35 psf B/C Live: 0 psf T/C Dead: 10 psf B/C Dead: 0 psf Load Case: Snow Deflection Criteria: L/360 Live L/240 Total Building Code: IBC/IRC (Allowable Stress De Design assumes continuous lateral bracing for both edges.0.85kips2.31kips0.85kips2.31kips0.83kips2.31kips0.83kips2.31kips0.31kips0.82kips0.31kips0.82kipsB 10 plyB 30 plyB 40 plyG 20 ply24' 0"22' 0" CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:20am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB2 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 1.50" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.50" 27 13 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 2.50" 31 39 Snow Replacement Uniform (PLF) Top 0' 0.00" 16' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 3.00" 27 7 Live Replacement Uniform (PLF) Top 11' 0.50" 16' 3.00" 31 39 Snow Point (LBS) Top 5' 2.50" 7 840 Live Point (LBS) Top 5' 2.50" 2310 0 Snow Point (LBS) Top 11' 0.50" 7 840 Live Point (LBS) Top 11' 0.50" 2310 0 Snow 1 2 16 3 0 16 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 3714# -- 2 16' 3.000" Wall N/A N/A 1.500" 3700# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 324# 2472# 1242# 2 297# 2472# 1229# Design spans 16' 1.750" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 17938.'# 33390.'# 53% 8.12' Total Load D+S Shear 3591.# 10706.# 33% 15.39' Total Load D+S TL Deflection 0.5466" 0.8073" L/354 8.12' Total Load D+S LL Deflection 0.3757" 0.5382" L/515 8.12' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:36am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 9.00" 1 57 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 9.00" 193 0 Snow 1 2 8 9 0 8 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1104# -- 2 8' 9.000" Wall N/A N/A 1.500" 1104# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2# 832# 272# 2 2# 832# 272# Design spans 8' 7.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2386.'# 3946.'# 60% 4.38' Total Load D+S Shear 907.# 2872.# 31% 0.06' Total Load D+S LL Deflection 0.0874" 0.2882" L/999+ 4.38' Total Load S TL Deflection 0.1159" 0.4323" L/895 4.38' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:36am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB3 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 7.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 3.00" 8 2 Snow Replacement Uniform (PLF) Top 0' 0.00" 3' 3.00" 23 7 Snow Point (LBS) Top 1' 7.50" 13 1599 Live Point (LBS) Top 1' 7.50" 4620 0 Snow 1 2 3 3 0 3 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 3185# -- 2 3' 3.000" Wall N/A N/A 1.500" 3185# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 7# 2359# 825# 2 7# 2359# 825# Design spans 3' 1.750" Product: 1-3/4x7-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4950.'# 9634.'# 51% 1.62' Total Load D+S Shear 3156.# 5544.# 56% 0.06' Total Load D+S TL Deflection 0.0318" 0.1573" L/999+ 1.62' Total Load D+S LL Deflection 0.0236" 0.1049" L/999+ 1.62' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:36am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB4 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 1.00" 8 2 Snow Replacement Uniform (PLF) Top 0' 0.00" 6' 1.00" 23 7 Snow Point (LBS) Top 3' 0.50" 13 1599 Live Point (LBS) Top 3' 0.50" 4620 0 Snow 1 2 6 1 0 6 1 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 3259# -- 2 6' 1.000" Wall N/A N/A 1.500" 3259# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 7# 2404# 855# 2 7# 2404# 855# Design spans 5' 11.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9520.'# 16051.'# 59% 3.04' Total Load D+S Shear 3219.# 7265.# 44% 0.06' Total Load D+S TL Deflection 0.0985" 0.2990" L/728 3.04' Total Load D+S LL Deflection 0.0728" 0.1993" L/985 3.04' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:31am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcA2 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PSF Deck Connection: Glued & Nailed Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Point (PLF) Top 0' 4.63" 1 128 Live Point (PLF) Top 0' 4.63" 193 0 Snow Point (PLF) Top 21' 7.38" 1 128 Live Point (PLF) Top 21' 7.38" 193 0 Snow 1 2 22 0 0 22 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 929# -- 2 22' 0.000" Wall N/A N/A 1.500" 929# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 567#(425plf) 257#(193plf) 312#(234plf) 2 567#(425plf) 257#(193plf) 312#(234plf) Design spans 21' 2.750" Product: 14" AJS 20 16.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3756.'# 5297.'# 70% 11' Total Load D+L Shear 708.# 1792.# 39% 0' Total Load D+L End Reaction 708.# 1250.# 56% 0' Total Load D+L TL Deflection 0.4776" 1.0615" L/533 11' Total Load D+L LL Deflection 0.3821" 0.7076" L/666 11' Total Load L Control: Pos. Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 KeiterScottLaddGarage - Level 3- 7-18 7:34am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 24.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 0.00" 1 67 Live Replacement Uniform (PLF) Top 0' 0.00" 3' 0.00" 1 67 Live Replacement Uniform (PLF) Top 0' 0.00" 3' 0.00" 193 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 3' 0.00" 193 0 Snow Replacement Uniform (PLF) Top 3' 0.00" 7' 9.00" 1 57 Live Replacement Uniform (PLF) Top 3' 0.00" 7' 9.00" 193 0 Snow Replacement Uniform (PLF) Top 3' 0.00" 21' 0.00" 1 57 Live Replacement Uniform (PLF) Top 3' 0.00" 21' 0.00" 193 0 Snow Replacement Uniform (PLF) Top 7' 9.00" 16' 3.00" 1 57 Live Replacement Uniform (PLF) Top 7' 9.00" 16' 3.00" 193 0 Snow Replacement Uniform (PLF) Top 16' 3.00" 21' 0.00" 1 57 Live Replacement Uniform (PLF) Top 16' 3.00" 21' 0.00" 193 0 Snow Replacement Uniform (PLF) Top 21' 0.00" 24' 0.00" 1 67 Live Replacement Uniform (PLF) Top 21' 0.00" 24' 0.00" 1 67 Live Replacement Uniform (PLF) Top 21' 0.00" 24' 0.00" 193 0 Snow Replacement Uniform (PLF) Top 21' 0.00" 24' 0.00" 193 0 Snow 1 2 24 0 0 24 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 2.337" 6134# -- 2 24' 0.000" Wall N/A N/A 2.337" 6134# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 13# 4472# 1662# 2 13# 4472# 1662# Design spans 23' 2.750" Product: 1-3/4x24 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 35396.'# 92421.'# 38% 12' Total Load D+S Shear 5048.# 18354.# 27% 0.4' Total Load D+S TL Deflection 0.4265" 1.1615" L/653 12' Total Load D+S LL Deflection 0.3128" 0.7743" L/891 12' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives