16-095CORLISS LAW OFFICE
FLORENCE, MASSACHUSETTS 01062
100 MAIN STREET
Renovation for:
INDEX TO DRAWINGSALTERNATESGENERAL NOTES
CONSTRUCTION CLASSIFICATION
OCCUPANCY CLASSIFICATION
APPLICABLE CODES & STANDARDS
BUILDING CODES AND STANDARDS
1. MASSACHUSETTS STATE BUILDING CODE (780 CMR),
8TH EDITION
2. MASSACHUSETTS ELECTRIC CODE (527 CMR), NEC 2017
WITH MASSACHUSETTS AMENDMENTS
3. NFPA 101 LIFE SAFETY CODE (2015 EDITION)
4. MASSACHUSETTS ARCHITECTURAL ACCESS BOARD
REGULATIONS (521 CMR), 2006 EDITION
5. MASSACHUSETTS STATE PLUMBING CODE (248 CMR)
B - BUSINESS
TYPE V-A
1.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALL
WORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL SUB-CONTRACTORS
ARE IDENTIFIED IN A SUMMARY OF WORK ON PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS AS PART OF THIS SET OF CONTRACT DRAWINGS.
2.THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA.
3.THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLY
WITH ALL SUBCONTRACTORS AND THE OWNER.
4.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP.
5.THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES.
6.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, 8TH EDITION, WITH ALL OF ITS REFERENCED
PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS.
7.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE ( NFPA 101, 2015
ED.).
8.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THE
OWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE.
9.THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK.
10.THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED.
GI001 TITLE SHEET
GI002 INFORMATION SHEET
A101 FLOOR PLAN, WALL TYPES & DETAILS
A102 REFLECTED CEILING PLAN
A201 INTERIOR ELEVATIONS
A501 DETAILS
A601 DOOR & WINDOW SCHEDULES AND DETAILS
A602 GLASS WINDOW WALL (BASE BID)
AF601 FINISH SCHEDULE
P101 PLUMBING PLAN, DETAILS & SCHEDULE
M101 HVAC PLAN & SCHEDULE
E101 ELECTRICAL LIGHTING PLAN & ELECTRICAL DEVICE PLAN
1.ALTERNATE NO. 1:
UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEW
CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE
OF WORK.
2.ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY
OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK.
DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND
EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION.
3.ALTERNATE NO. 3:
UNDER ALTERNATE NO. 3, DELETE ELEVEN (11) RECESSED LED FIXTURES IN CONFERENCE ROOM
#109, AND INSTALL SIX (6) NEW 2X2 LED RECESSED TROFFERS AS SHOWN ON SHEET A102:
REFLECTED CEILING PLAN AND SHEET E101: ELECTRICAL POWER AND LIGHTING PLAN; SEE
OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK.
4.ALTERNATE NO. 4:
UNDER ALTERNATE NO. 4, DELETE THE GLASS WINDOW WALL AT CONFERENCE ROOM #109, AND
PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM AND GLASS STOREFRONT SYSTEM
(KAWNEER TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR, OR EQUAL); SEE SHEET A601 AND
SHEET A602.TITLE SHEET
GI001
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:28 PM
ZONING DISTRICT:
PRINCIPAL USE:
ZONING RESTRICTIONS RELATIVE TO USE:
NOT APPLICABLE
PARKING REQUIREMENTS:
NOT APPLICABLE
ADDITIONAL REQUIREMENTS:
NOT APPLICABLE
INTERIOR ELEVATION DESIGNATION
DETAIL IDENTIFICATION
ELEVATION LETTER
SECTION DESIGNATION
ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN
SECTION DESIGNATION ROOM AND NAME NUMBER
ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN
ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN
DETAIL DESIGNATION
DOOR NUMBER
KEY NOTE
WALL TYPE
HEIGHT MARK
DETAIL DESIGNATION
ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN
DETAIL DESIGNATION
SECTION DESIGNATION
FIXTURE AND MISC. ACCESSORIES HEIGHTS
15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the lens of the strobe
shall be no less than 80" and no greater
than 96" AFF. When clg heights don't
allow for a min. height of 80", strobes
shall be mounted within 6" of clg
17"
MIN.34" MAX.TO RIMINSULATE ALL PLUMBING
W/ TRUEBRO LAVATORY GUARD
OR EQUAL
FINISH FLOOR 15"-48"MIN MAX48"48"
LINE
FINISH FLOOR
LINE
The highest operable part of telephone,
including dial, handset and coin deposit slots
shall be within the reach ranges specified in
ABA Section 30815"MINAccessible storage spaces shall be within
at least one of the reach ranges specified
in ABA Sections 308 29"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEHIGHEST
OPERABLE
PART
HIGHEST
OPERABLE
PART
HIGHEST
OPERABLE
PART
15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48"
CLR. FLR.
SPACE
FIRE HORN AND LIGHT FIRE EXTINGUISHER
CABINET
PUBLIC TELEPHONE (ELEVATION)
30"x48" CLR. FLOOR SPACE
FOR FORWARD APPROACH
PUBLIC TELEPHONE
(PLAN)
CLOTHES HOOK/ROD DUPLEX RECEPTACLE
30"x48" CLR. FLOOR
SPACE
LAVATORY (ELEV.)LAVATORY FORWARD
APPROACH (PLAN)
MIRROR DRINKING FOUNTAIN
(PARALLEL APPROACH)
FREE STANDING OR
BUILT-IN UNITS
DRINKING FOUNTAIN
(FORWARD APPROACH)
WALL & POST MOUNTED
CANTILEVERED UNITS
ACCESSIBLE
DRINKING FOUNTAIN
(ELEV.)
MIN. SHOWER
CONFIGURATION PLAN
SOAP DISPENSER NAPKIN/TAMPON
VENDOR
PAPER TOWEL
DISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARM
PULL STATION42"-48"OPTIONAL POST
OR BASE 4'-0"MAX.8"
MIN.30"x48" CLR.
FLOOR SPACE
30"x48" CLR.
FLOOR SPACE6" MAX.
TOE CLEARANCE
6" MAX.
TOE
CLEARANCE
15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH
RANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6
HIGHEST
OPERABLE
PART
FOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEE
PLAN
FORUNOBSTRUCTEDSIDE ORFORWARD REACH9" MIN.TOECLEARANCE17"MIN.5"
MAX.
5"
MAX.
SPOUT
LOCATION SPOUT
LOCATION
15"
MIN.
15"
MIN.9" MIN.TOE CLEARANCE8" MIN.
KNEE CLEARANCE
MIRROR
-REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACES
SHALL BE PERMITTED TO OVERLAP.
-DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED
TURNING SPACE.
1
A101
A
B
C
D 2
A102
1
A101
CONFERENCE
ROOM
1005
201
2
CEILING HEIGHT
EL. = 100'-0"
36
A101
EXIT REQUIREMENTS:
OCCUPANCY LOAD:
1,173 SF @ 100 SF / OCCUPANT = 12 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1)
MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS):
MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS):
NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1009.1, NOT LESS THAN 44")
REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP B):
2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1)
CORRIDORS: 36" MIN. REQUIRED, 63" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2)
DOORS: 36" MIN. REQUIRED, 36" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1005.1)
FEMALE TOILET 1 PER 20 OCC = 1 REQUIRED, 1 PROVIDED
RAMPS: NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1010.5)
FEMALE SINKS 1 PER 40 OCC = 1 REQUIRED, 1 PROVIDED
MALE TOILET 1 PER 25 OCC = 1 REQUIRED, 1 PROVIDED
MALE SINKS 1 PER 40 OCC = 1 REQUIRED, 1 PROVIDED
EYE/FACE WASH
(SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR.
FLOOR SPACE
EYE/FACE WASH
(PLAN)
PAPER TOWEL DISPENSER
AND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEAT
AS REQUIRED
FRONT ELEV.
BABY CHANGING STATION
SIDE ELEV.PLAN48"MAXTO OPERABLEPORTION34"MAX.TO HIGHEST PART OF WORKSURFACE IN DOWN POSITION27"MIN.TO BOTTOM OF WORKSURFACE30"x48" MIN.
17" - 25"
TOE CLEARANCE
30"
OR WIDTH OF TABLE
48"25"OR LESS44" MAXLATCHABBREVIATIONS
33"-36"MIN. MAX.7"-9"
MIN. MAX.15"-48"MIN. MAX.12"
MAX.42"
MIN.12"
MIN.33"-36"MIN. MAX.FINISH FLOOR
LINE
13-1/2"
MIN.
Mount on side wall closest to
water closet; shall not be
located behind grab bar
Grab bars shall be between 1-1/4" and
LQDQGORFDWHGFOHDU
from wall 17"-19"MIN. MAX.18"
TOILET TISSUE
DISPENSER/HOLDER
TOILET CLOSEST SIDE WALL
GRAB BARS (ELEV.)
TOILET REAR WALL GRAB
BARS (ELEVATION)
TOILET
(SIDE ELEVATION)
Flush controls shall be located on the open
side of water closet or directly behind the toilet.
TOILET
(FRONT ELEVATION)
URINAL
(ELEVATION)
URINAL
(PLAN)
36"
MIN.
24"
MIN.
OPEN SIDE
54"
MIN.
TRANSFER
SIDE
SIDE WALL
17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 308CLEARANCE AT
TOILET (PLAN)
5'-6"
MIN.6'-0"MIN.18"
30"x48" CLR.
FLOOR SPACE
6'-0" X 5'-6" MIN.
CLEAR FLOOR
SPACEPREFERRED
LOCATION IS
BELOW GRAB BAR
@ 2'-0" A.F.F. TO
CENTER OF
DISPENSER
6"
MIN.33"-36"MIN. MAX.TOILET REAR WALL GRAB
BARS (ELEV.)
3'-6"
MIN.
3'-0"
MIN.OPEN SIDE
ȭ
TRANSFER
SIDE
SWING-UP GRAB BAR W/
INTEGRAL TOILET PAPER
DISPENSER (ELEV.)
CIRCULAR SPACE T-SHAPED SPACE
This space shall be
permitted to include knee
and toe clearance
complying with ABAAS
Section 306
60" DIA.
(MIN.)36"24"12"36"12"
60"60"This space shall be permitted
to include knee and toe
clearance complying with
ABAAS Section 306 only at
the end of the base or one
arm
NURSE CALL LIGHT6"EQ.EQ.
CL
CL
NURSE CALL LIGHT;
SEE ELEC. DWGS.
2'-5"3'-0"ZONING ANALYSIS
CODE ANALYSIS
GRAPHIC SYMBOLS
ANCHOR BOLT
ACOUSTICAL
AIR CONDITIONER
ADJACENT
ABOVE FINISH FLOOR
ALTERNATE
ALUMINUM
ANCHOR
ANODIZED
ARCHITECT
B.L.
BD.
BLDG.
BLK.
BLKG.
B.O.
A.B.
ACOUST.
A.C.
ADJ.
A.F.F.
ALT.
ALUM.
ANCH.
ANOD.
ARCH.
BTM.
BRG.
BRK.
BUILDING LINE
BOARD
BUILDING
BLOCK
BLOCKING
BOTTOM OF
BOTTOM
BEARING
BRICK
CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CABINET
CORNER GUARD
CONTROL JOINT
CLOSET
CENTER
CEILING
CLEAR (DIMENSION)
CONCRETE MASONRY UNIT
COLUMN
COMPACTED (COMPOSITION)
CONCRETE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CERAMIC TILE
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DOWN
DOOR
DETAIL
DRAWINGS
EAST
EXTERIOR INSULATION & FINISH
SYSTEM
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELEVATOR
EQUAL
EQUIPMENT
EMERGENCY ROOM
EXISTING TO REMAIN
ELECTRIC WATER COOLER
EXHAUST
EXISTING
EXPANSION
EXTERIOR
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FLOOR
FINISH
FACE OF FINISH
FACE OF FOUNDATION WALL
FACE OF MASONRY
FACE OF STUD
FIELD VERIFY
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLASS
GENERAL
GLAZE
GRADE
GYPSUM WALL BOARD
HANDICAPPED
HEIGHT
HOLLOW METAL
HOT WATER HEATER
HEATING, VENTILATING AND AIR
CONDITIONING
INSIDE DIAMETER
INSULATED HOLLOW METAL
INSULATED STEEL
INSULATION
INTERIOR
JANITOR
JOIST
JOINT
KICKPLATE (HEIGHT")
LAMINATE
LAVATORY
MASONRY
MAXIMUM
MECHANICAL
MECHANICAL, ELECTRICAL, PLUMBING
MANUFACTURER
MOUNTED
METAL
MINERAL CORE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MULLION
NORTH
NATURAL
NAPKIN DISPENSER
NECESSARY
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OWNER FURNISHED, CONTRACTOR
INSTALLED
OWNER FINISHED, OWNER INSTALLED
OPENING
OPPOSITE
PROPERTY LINE
PARTICLE BOARD
PLASTIC LAMINATE
PLASTER
PAINT
PAINTED
PARTITION
POLYVINYL CHLORIDE
PLYWOOD
ROOF DRAIN
REFERENCE
REFRIGERATOR
REINFORCE
REQUIRED
ROUGH
ROOM
ROUGH OPENING
SOUTH
SOLID CORE WOOD
SECTION
SQUARE FOOT
SIMILAR
SURFACE MOUNTED
SPECIFICATIONS
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPEND(ED)
SYSTEM
TEMPERED
TOP OF
TELEPHONE
THICK
TEMPERED INSULATED
TOILET
TYPICAL
TOP OF FOUNDATION
TOP OF WALL ELEVATION
TOP OF STEEL ELEVATION
TOP OF SLAB
UNDER COUNTER REFRIGERATOR
UNIT HEATER
UNDERSIDE OF DECK
UNLESS NOTED OTHERWISE
URINAL
VINYL BASE
VINYL COMPOSITION TILE
VERTICAL
VESTIBULE
VERIFY IN FIELD
WEST
WITH
WITHOUT
WITHIN
WATER CLOSET
WOOD
1/4" WIRE GLASS
1/4" TEMPERED GLASS
CAB.
C.F.C.I.
C.G.
C.J.
CL.
CTR.
CLG.
CLR.
CMU
COL.
COMP.
CONC.
CONST.
CONT.
CONTR.
C.T.
D.F.
DIA.
DIM.
DN
DR.
DTL.
DWGS.
E
E.I.F.S.
E.J.
EL.
ELEC.
ELEV.
EQ.
EQUIP.
E.R.
E.T.R.
E.W.C.
EXH.
EX.
EXP.
EXT.
F.D.
FDN.
F.E.
F.E.C.
F.H.C.
FIN.
FLR.
F.O.F.
F.F.
F.O.M.
F.O.S.
F.V.
GA.
GALV.
G.C.
GEN.
GL.
GLZ.
GRD.
G.W.B.
H.C.
HGT.
H.M.
H.W.H.
HVAC
I.D.
I.H.M.
I.S.
INSUL.
INT.
JAN.
JST.
JT.
K(12)
LAM.
LAV.
MAS.
MAX.
MECH.
M.E.P.
MFR.
MTD.
MTL.
MIN
MIN.
MISC.
M.O.
MULL.
N
NAT.
N.D.
NEC.
N.I.C.
N.T.S.
O.C.
O.F.C.I.
O.F.O.I.
OPG.
OPP.
P.L.
PBD.
PLAM.
PLAS.
PT.
PTD.
PTN.
PVC
PLYWD.
R.D.
REF.
REFR.
REINF.
REQ'D
RGH.
RM.
R.O.
S
S.C.W.
SECT.
SF
SIM.
S.M.
SPEC.
S.S.
STD.
STL.
STOR.
STRUCT.
SUSP.
SYS.
T.
T.O.
TEL.
THK.
T.I.
TLT.
TYP.
T.O.F.
T.O.W.
T.O.S.
T.SLB.
U.C.REFR.
U.H.
U.O.D.
U.N.O.
UR.
V.B.
V.C.T.
VERT.
VEST.
V.I.F.
W
W/
W/O
W/IN
W.C.
WD.
1/4 W.G.
1/4 T.
REFLECTED CEILING PLANRCP
GOVERNMENT FURNISHED
PROPERTY
GFP
INFORMATION SHEET
GI002
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:31 PM
FURNITURE SHOWN ON DRAWINGS, EXCEPT CASEWORK, IS NOT INCLUDED IN THIS CONTRACT
UNLESS NOTED OTHERWISE.
10.
ALL DOORS AND WALLS NOT LABELED WITH A WALL TYPE OR DOOR NUMBER ARE TO BE
CONSIDERED EXISTING TO REMAIN.
9.
GENERAL CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL WALLS, NEW OR EXISTING,
THAT ARE TO RECEIVE NEW OR EXISTING CABINETRY, SHELVING, ETC.; COORDINATE W/OWNER.
8.
WHERE UTILITY AND MECHANICAL WORK IS REMOVED OR ALTERED, GENERAL CONTRACTOR IS
RESPONSIBLE FOR PREPARING AND PATCHING BUILDING STRUCTURE TO MATCH NEW AND
EXISTING WORK AS INDICATED ON DRAWINGS.
7.
ALL WORK TO BE CONSIDERED AS NEW WORK UNLESS INDICATED AS EXISTING TO REMAIN.6.
CONSTRUCT NEW INTERIOR PARTITIONS FROM FLOOR TO THE UNDERSIDE OF THE STRUCTURE
ABOVE (DECK OR SLAB) UNLESS NOTED OTHERWISE; VERIFY IN FIELD.
5.
REPAIR ANY IRREGULARITIES IN SURFACES INCLUDING BUT NOT LIMITED TO AREAS DISTURBED
BY NEW WORK.
4.
PROVIDE TEMPORARY DUST PROOFING PARTITIONS TO EFFECTIVELY SEAL OFF WORK AREAS
FROM THE REST OF THE BUILDING. PROVIDE TEMPORARY DOOR IF NECESSARY.
3.
2.ANY REPAIRS, PATCHING, OR DEMOLITION INDICATED ON DRAWINGS REPRESENT THE GENERAL
AREA WHERE WORK IS TO BE DONE, BUT DOES NOT NECESSARILY LIMIT THE EXTENT OF WORK.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SUCH REPAIRS, PATCHING, ETC. WHERE
THEY OCCUR IN BUILDING UNDER THIS CONTRACT.
1.GENERAL CONTRACTOR MUST VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND
REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH THE WORK.
GENERAL CONSTRUCTION NOTES
ROOM NAME AND ROOM NUMBER
DOOR NUMBER
NEW WALL CONSTRUCTION
EXISTING CONSTRUCTION
LEGEND
WALL TYPE
PRIVACY CURTAIN (N.I.C.)
NEW HALF WALL CONSTRUCTION (U.N.O.)
ROOM
NAME
XXX
XXX
1
NEW MILLWORK / CASEWORK WITH PLASTIC LAMINATE COUNTERTOP
NEW MILLWORK / CASEWORK WITH SOLID SURFACE COUNTERTOP
WAITING
102
218 SF
M
DN
DN
UP
RAMP
W
EXISTING GAS SERVICE
METER
ELECTRIC SERVICE PANELS AND METERS
KITCHEN
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WORK
STATION
WORK
STATION
WORK
STATIONSTORAGE
CONFERENCE
CL
FRIDGE
FLOOR PLAN
SCALE: 1/4" = 1'-0"
WORK
STATION
WORK
STATION
5'-31316r21'-77
16"
CONFERENCE
ROOM
109
214 SF
FILES/ STORAGE
110
115 SF14'-1178r14'-3"
ATTORNEY
OFFICE
104
153 SF 13'-10"11'-1"
ADMIN
OFFICE
103
103 SF
11'-33
4"
CHECK-IN
WINDOW
ACOUSTICAL GLASS
WALL AND DOOR SYSTEM 1'-0" MIN. CLRENTRANCE
VESTIBULE
101
42 SF
7'-0" CLEAR5'-0" CLEARCOAT RACK
REF.(U.C.)MICRO6'-9316rTV
5'-113
4" V.I.F.
FULL-HEIGHT
CABINET
COPIER
4'-7"3'-4"1'-0"2'-1"3'-2"
WORK COUNTER W/
UPPER CABINETS ABOVE
5'-4316rCOPY
AREA
105
82 SF
2'-0"
D 7
A201
C
D 6
A201
A
5
A201
HALL
106
83 SF
W1
W2
A
B
C
D 1
A201
E.P.
101
109
110
103
104
1
1
1
1
1
2
4
1'-11 116"
W3 6'-10"1
5'-31
2"23'-234" V.I.F.9'-1" V.I.F.12'-21516"7'-934" V.I.F.7'-4"7'-0"
ALIGN
3'-6"
1'-10"
ȭ
ȭ
2'-1"
1'-2"
3'-6"
ȭ
STAFF
BREAK
107
53 SF
TOILET
108
51 SF
106 NEW ALUMINUM ENTRANCE DOOR WITH TRANSOM-
SEE DOOR SCHEDULE; REMOVE EXISTING WINDOW
WITH TRANSOM ABOVE (SALVAGE WINDOW AND
TRANSOM FOR RELOCATION AS SHOWN) AND
PREPARE MASONRY OPENING FOR NEW WORK.
NEW LOCATION FOR SALVAGED WINDOW AND
TRANSOM - SEE WINDOW SCHEDULE; REMOVE
EXISTING DOOR AND TRANSOM AND PREP
MASONRY OPENING FOR NEW WORK. RELOCATE
EXISTING FIRE ALARM NOTIFICATION DEVICES AS
REQUIRED (TYPICAL)
W4
7'-0"
ALIGN
P
P
F
F
F
B8
A201
A
3'-6"
A
D 11
A201
NEW RECESSED FIRE EXTINGUISHER CABINET,
MODIFY EXISTING WALL AS REQUIRED TO
MAINTAIN FULL CLEAR WIDTH OF HALLWAY.
FURR WALL AT REAR OF FIRE EXTINGUISHER
CABINET AS REQ'D.1'-6"1'-3"NEW WINDOW SHADES AT ALL EXTERIOR WINDOWS -
SEE FINISHES PLAN.
UPPER CABINETS
ALTERNATE NO. 1:
UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK
IN CONFERENCE ROOM #109 (NEW CASEWORK BY
OWNER); SEE SHEET A101 AND OTHER SHEETS AS
MAY REFERENCE THE SCOPE OF WORK.
ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK
IN COPY AREA #105 (NEW CASEWORK BY OWNER);
SEE SHEET A101 AND OTHER SHEETS AS MAY
REFERENCE THE SCOPE OF WORK. DELETE TWO (2)
UNDER-CABINET LIGHTS AND PLASTIC LAMINATE
SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW
SUSPENDED ACOUSTICAL CEILING TO PARTITION.
1'-6"3'-6" (=)3'-6" (=)4'-312"
ȭȭ
NEW SERVICE SINK - SEE PLUMBING DRAWINGS;
SAWCUT EXISTING CONCRETE SLAB FOR
EXTENSION OF SANITARY PIPING TO NEW
PLUMBING FIXTURE; MODIFY EXISTING WALL
CONSTRUCTION TO ACCOMMODATE NEW
PLUMBING PIPING (TYPICAL); INFILL CONCRETE
SLAB - SEE DETAIL 18/A101
VISION PANEL
ALTERNATE NO. 4:
UNDER ALTERNATE NO. 4, DELETE THE GLASS
WINDOW WALL AT CONFERENCE ROOM #109, AND
PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM
AND GLASS STOREFRONT SYSTEM (KAWNEER
TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR,
OR EQUAL); SEE SHEET A601 AND SHEET A602.
NEW ALUMINUM ENTRANCE DOOR
- SEE DOOR SCHEDULE
2'-212"
ȭ
3
834"EXISTING ELECTRICAL PANEL TO REMAIN
ALIGN
1 WALL TYPE
SCALE: 1" = 1'-0"
FLOOR LINE
5/8" TYPE "X" GYPSUM BOARD (EACH SIDE)
BATT SOUND INSULATION
NON-RATED WALL
BASE - SEE ROOM FINISH SCHEDULE
CEILING
SEE R.C.P.
LINE OF STRUCTURAL DECK OR SLAB ABOVE
USE MOISTURE RESISTANT GYPSUM
BOARD FOR ALL WET AREAS
FLOOR LINE
12" H CLEAR ANODIZED ALUMINUM REVEALS
FASTEN PLATE SECURELY TO FLOOR3'-6" (N.T.S.)BASE PER FINISH SCHEDULE
1/2" SOLID SURFACE CAP- SEE ROOM FINISH SCHEDULE1/4"2 HALF-HEIGHT WALL
SCALE: 1" = 1'-0"
NON-RATED WALL
METAL CORNER BEAD (TYP.)
10 GA. WALL SUPPORT FRAMING REINFORCEMENT UNIT -
3.625" x 24" SECURED TO FLOOR WITH 1/2" ACCESSORY
PLATE AND (2) 3/8" DIA. EXPANSION ANCHORS, 3-1/2"
EMBEDMENT. UNITS AT ADJACENT TWO STUDS AT END OF
WALL AND @32" O.C.
1/4" ALUMINUM REVEAL (ALL EXPOSED SIDES)
1/2" SOLID SURFACE CAP- SEE ROOM FINISH SCHEDULE
NOTE: FASTEN ONE END OF WALL
TO FULL HEIGHT WALL. PROVIDE
BLOCKING AND SUPPORT AS
REQUIRED
3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL
EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE.2'-0" A.F.F. (N.T.S.)3 WALL TYPE
SCALE: 1" = 1'-0"
FLOOR LINE
5/8" TYPE "X" GYPSUM BOARD
BATT SOUND INSULATION
NON-RATED WALL
BASE - SEE ROOM FINISH SCHEDULE
CEILING
SEE R.C.P.
LINE OF STRUCTURAL DECK OR SLAB ABOVE
USE MOISTURE RESISTANT GYPSUM
BOARD FOR ALL WET AREAS
EXISTING WALL CONSTRUCTION
3-5/8" METAL STUDS @ 16" O.C.
3-5/8" METAL STUDS @ 16" O.C.
2-1/2" METAL STUDS @ 16" O.C.
4 WALL TYPE
SCALE: 1" = 1'-0"
FLOOR LINE
5/8" TYPE "X" GYPSUM BOARD (EACH SIDE)
BATT SOUND INSULATION
NON-RATED WALL
BASE - SEE ROOM FINISH SCHEDULE
CEILING
SEE R.C.P.
LINE OF STRUCTURAL DECK OR SLAB ABOVE
USE MOISTURE RESISTANT GYPSUM
BOARD FOR ALL WET AREAS
3-5/8" METAL STUDS @ 16" O.C.
SEE FLOOR
PLAN 2'-0"
TYPICAL
VARIESDRILL EXISTING CONCRETE SLAB FOR
NEW STEEL DOWEL
EXISTING
CONCRETE SLAB
PLAN
SECTION
NEW PIPING
NEW CONCRETE SLAB (4000 PSI)
EXISTING CONCRETE SLAB
6" MIN. BEDDED SAND (TYPICAL)
NEW CONCRETE SLAB (4000 PSI)VARIESSEE SITE COND.WATERSTOP
(TYPICAL)
NEW 1/2" x 8" MINIMUM STEEL DOWEL
ANCHORED INTO EXISTING & NEW
CONC. SLABS@ 3'-0" O.C., EACH SIDE
OF TRENCH (TYPICAL)
CONTRACTOR TO PROVIDE 10-MIL
VAPOR BARRIER BELOW PROPOSED
CONCRETE WORK AND OVERLAP
EXISTING VAPOR BARRIER (12" MINIMUM)
- TAPE ALL EDGES
PLUMBING FLOOR PATCH DETAIL
SCALE: N.T.S.
-
-
ALIGN
2" MIN. COVER SAND OR STONE DUST
(TYPICAL)
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:
FLOOR PLAN & WALLTYPES
A101
BW
5/4/2017 4:38 PM
ADMIN. OFFICE #103
INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
6
A101
C D
BASE PER FINISH
SCHEDULE (TYP.)2'-10"4'-0"
COPY AREA #105
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
5
A101
A
BASE PER FINISH
SCHEDULE (TYP.)
PLASTIC LAMINATE
SOFFIT- SEE
REFLECTED CEILING
PLAN
3'-0"4'-6"1"
COUNTERTOP
OVERHANG3'-0"7'-0"3'-0"2'-3"2'-0"2'-0"3'-3"2'-3"
STAFF BREAK #107
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
7
A101
D
BASE PER FINISH
SCHEDULE (TYP.)2"
FILLER2'-6"
LIGHT VALANCE - SEE
ELECTRICAL
DRAWINGS
2'-6"2"
FILLER
FRIDGE
(U.C.)
2'-6"
134r
FILLER
2'-734"2'-6"
2'-6"
W1 W2
4'-2"4'-2"2'-10"2"
FILLER
2"
FILLER
2"
FILLER
TRASH/
RECYCLE
BIN
TRASH/
RECYCLE
BIN
WAITING ROOM #102
INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
1
A101
A
BASE PER FINISH
SCHEDULE (TYP.)2'-10"4'-0"
W1
4'-2"B
CONFERENCE ROOM #109
INTERIOR ELEVATIONS
SCALE: 1/4" = 1'-0"
8
A101
HANDWASHING SINK -
SEE PLUMBING DWGS
SOAP
DISPENSER @42"
A.F.F. (C.F.C.I.)
PAPER TOWEL
DISPENSER @42"
A.F.F. (C.F.C.I.)
ALL EXPOSED ENDS
FINISHED (TYP.)3'-0"2'-0"2'-0"8
A501
LOW WALL W/ SOLID SURFACE
CAP- SEE WALLTYPES & FINISH
SCHEDULE
A
BASE PER FINISH
SCHEDULE (TYP.)3'-0"BASE PER FINISH
SCHEDULE (TYP.)
W3
8'-0"C
9
A501
W3
D
TOILET #108
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
11
A101
EXISTING MIRROR
BY BLDG OWNER;
CONTRACTOR TO
INSTALL
EXISTING LAVATORY
BY BLDG OWNER;
CONTRACTOR TO
INSTALL
SOAP DISPENSER @42" A.F.F.
(O.F.C.I.)
PAPER TOWEL
DISPENSER
(O.F.C.I.)
1-1/2" DIA. STAINLESS
STEEL GRAB BARS
(O.F.C.I.)
TOILET PAPER DISPENSER
@24" A.F.F. (O.F.C.I.)
EXISTING WATER CLOSET
BY BLDG OWNER;
CONTRACTOR TO INSTALL BASE - SEE ROOM FINISH
SCHEDULE
6"3'-6"1'-0"3'-6"2'-10"BASE - SEE ROOM FINISH
SCHEDULE
D B
EXISTING PRE-FORMED
INSULATING KNEE GUARD BY
BLDG OWNER; CONTRACTOR
TO INSTALL
1-1/2" DIA. STAINLESS
STEEL GRAB BARS
(O.F.C.I.)2'-10"8"
2"
FILLER
2"
FILLER
2
A501
3
A501
6
A501
7
A501
LOW WALL W/ SOLID SURFACE
CAP- SEE WALLTYPES & FINISH
SCHEDULE
12
A501
TV
3'-0"3'-0"3'-0"3'-0"2'-8"
PLASTIC LAMINATE
SOFFIT- SEE R.C.P.
AND DETAILS
BASE PER FINISH
SCHEDULE (TYP.)
16
A501
17
A501
ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN DELETE NEW
CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE
SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF
WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE
SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED
ACOUSTICAL CEILING TO PARTITION.
ALTERNATE NO. 1:
UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE
ROOM #109 (NEWCASEWORK BY OWNER); SEE SHEET A101 AND OTHER
SHEETS AS MAY REFERENCE THE SCOPE OF WORK.
BASE PER FINISH
SCHEDULE (TYP.)
B
FLAT SCREEN TV
(O.F.C.I.) &
ASSOCIATED TV
WALL BRACKET WITH
ADJUSTABLE ARM
(C.F.C.I.).
COORDINATE HEIGHT
W/ OWNER IN FIELD
GYPSUM SOFFIT- SEE
R.C.P. AND DETAILS
9'-0"
12'-2"
2 (OPEN TO
COPY AREA)
5'-0" CLEAR
TO DOOR
2
COPIER
(NIC)
EQ.EQ.
BASE BID - SEE
ALTERNATE NO. 4
BASE BID - SEE
ALTERNATE NO. 4
NOTE:
OWNER/CONTRACTOR TO VERIFY
EXTENT OF TOILET ACCESSORIES TO
BE PROVIDED BY BLDG OWNER (I.E.
GRAB BARS, MIRROR, ETC.). FOR
OWNER PROVIDED ITEMS
CONTRACTOR WILL BE REQUIRED TO
INSTALL THEM.
EXISTING WALL MOUNTED FIRE
ALARM HORN STROBE AND WALL
MOUNTED EMERGENCY LIGHT TO
REMAIN.
EXISTING LIGHT SWITCH TO REMAIN.
EXISTING EMERGENCY
LIGHT TO REMAIN
ALL EXPOSED ENDS
FINISHED (TYP.)
INTERIOR ELEVATIONS
A201
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:44 PM
1.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE BEGINNING WORK. FABRICATE CASEWORK IN
SECTIONS AS NECESSARY TO FACILITATE HANDLING AND BUILDING ENTRY. ALL SUCH CASEWORK
SECTIONS TO BE JOINED WITH SPLINES AND RV #315 TITE-JOINT FASTENERS.
MILLWORK NOTES
2.ALL CASEWORK AND MILLWORK FABRICATION AND MATERIALS TO EQUAL ARCHITECTURAL
WOODWORK INSTITUTE QUALITY STANDARDS "CUSTOM GRADE" OR BETTER.
3.CASEWORK IS TO BE FLUSH OVERLAY CONSTRUCTION. USE SCRIBE ENDS WHERE CASEWORK IS
EXPOSED. CAULK JOINTS TO ELIMINATE GAPPING BETWEEN DISSIMILAR MATERIALS, OR NEW
CASEWORK AND EXISTING CONSTRUCTION (TYPICAL). USE STILES WHERE NECESSARY TO MOUNT
HINGES TO ADJACENT DOORS. CAULK BACKSPLASHES TO COUNTERS, NO CAULK JOINT SHALL
EXCEED 1/8".
4.ALL CASEWORK CORES TO BE 3/4" PARTICLE BOARD EXCEPT AS NOTED.
5.ALL BASE CABINETS KICKS TO BE 3/4" SOLID WOOD OR VENEER PLYWOOD.
6.ALL INTERIOR SURFACE OF EXPOSED (OPEN) CABINETS SHALL BE PLASTIC LAMINATE TO MATCH
EXTERIOR OF CABINET. INTERIOR SURFACES OF UNEXPOSED (CLOSED WITH DOORS, DRAWERS, OR
PANELS) SHALL BE MELAMINE (WHITE) UNLESS OTHERWISE NOTED.
8.BACKS OF PLASTIC LAMINATED SURFACES SHALL RECEIVE BALANCE SHEET.
9.CABINET BACKS - USE PREFINISHED HARDBOARD (MELAMINE, ETC) WITH COLOR TO MATCH PLASTIC
LAMINATE CASEWORK. USE 1/2" HARDBOARD WITH PLASTIC LAMINATE AND BALANCE SHEET AT ALL
CASEWORK BACKS THAT ARE EXPOSED.
GENERAL CONTRACTOR IS TO PROVIDE BLOCKING IN WALLS FOR CASEWORK EVEN IF NOT
SPECIFICALLY INDICATED ON DRAWINGS.
11.
12. CABINETRY HARDWARE: FOR ADDITIONAL INFORMATION REFER TO SPECIFICATIONS.
PULLS - (US26D) BRUSHED CHROME (UNLESS NOTED OTHERWISE ON FINISH SCHEDULE), 4"
MOUNTED 1-3/4" IN FROM EDGE OF DOOR TOP AND SIDE. 1-3/4" FROM TOP OF DRAWER FACE,
CENTERED.
+,1*(6q23(1,1*&21&($/('6(/)&/26,1*
SHELF SUPPORTS - 32 MM LINE BORE SYSTEM WITH HAFELE #282.04.739 (METAL CLIPS);
LOCKS + CATCHES - KENSTAN CAM LOCK (KEY REMOVABLE IN UNLOCKED POSITION) WITH
2" MIN. ELBOW CATCH AT DOUBLE DOORS TO MATCH PULLS, ALIGNED WITH CENTER OF PULL;
TOUCH LATCH - EPCO #507 BLACK PLASTIC;
DRAWER SLIDES - BLUM STANDARD DRAWER SLIDE. FULL EXTENSION, WHITE.
13.SHELVES TO HAVE 3/4" CORE (TYPICAL TO 36"; >36" = 1" CORE). SHELVES TO BE FULL DEPTH OF
CABINET.
10.STENCIL PRODUCT NAME AND COLOR NAME & NUMBER AT UNDERSIDE OF ALL COUNTERTOPS,
INCLUDE DATE OF FABRICATION.
14 HARDWOOD NOSING OR HARDWOOD TRIM TO BE FINISHED WITH FOUR (4) COATS OF
POLYURETHANE. POLYURETHANE SHALL BE RUBBED WITH "PLASTIC WOOL" BETWEEN COATS TO
OBTAIN A SMOOTH SURFACE ON THE LAST COAT.
7.ALL EXPOSED SURFACES OF CASEWORK TO RECEIVE PLASTIC LAMINATE.
ADJUSTABLE SHELVES HARDWARE: KV 82/182 SHELVING SYSTEM WITH HEAVY DUTY BRACKETS AND
STANDARDS (ARCHITECT TO SELECT COLOR).
15.
COUNTER SUPPORT BRACKET: FAST CAP/SPEED BRACE SUPPORT BRACKET W/1/4" x 2" PHILIPS PAN
HEAD SHEET METAL SCREWS OR HEAVY DUTY TOGGLE BOLTS. CONTRACTOR TO DETERMINE MAX.
UNSUPPORTED SPANS AND OVERHANG WITH BRACKET MANUFACTURER (BLACK POWDER COAT
FINISH UNLESS OTHERWISE SPECIFIED BY ARCHITECT).
16.
17.ALL DRAWERS SHALL HAVE FULL HEIGHT SIDES AND BACK, UNLESS NOTED OTHERWISE.
18.CONTRACTOR TO PROVIDE RUBBER DOOR SILENCERS AT ALL DOOR AND DRAWERS.
19.GROMMETS (2-3/4" INTERIOR DIAMETER TYPICAL UNLESS NOTED OTHERWISE); COLOR TBD.
COORDINATE WITH COUNTER FINISH. QUANTITY T.B.D. (GROMMETS TO BE LOCATED IN FIELD BY
OWNER).
20.KEYBOARD TRAYS TO BE O.F.C.I.
21.PROVIDE SEAMING PLAN FOR ALL COUNTERS.
22.ALL SOLID SURFACE COUNTERTOP SHALL HAVE 1/4" RADIUS NOSING - SEE DETAIL 1/A501.
FINISHED FLOOR3'-0"2'-1"4"4"1" TYP
CABINET BASE- RECYCLING
SCALE: 1" = 1'-0"
8
A201 112"4" BACKSPLASH
PAPER SLOT- MIN. SIZE AS REQUIRED TO FIT
PAPER & RECYCLABLES
BASE PER SCHEDULE
CENTER DIVIDER PANEL (BETWEEN
TRASH AND RECYCLING CANS)
RECYCLING
CAN
SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER - SEE ROOM
FINISH SCHEDULE AND DETAIL 1/A501
NOTE: COUNTER SHALL BE SOLID SURFACE WHEN
OCCURRING AT SINK LOCATION
3/4" PARTICLE BOARD; PLASTIC LAMINATE
ON ALL EXPOSED SURFACES - SEE ROOM
FINISH SCHEDULE
SCRIBE AND CAULK CONTINUOUS BY
GENERAL CONTRACTOR
B/O SOFFIT
EL. = 7'-0"
1'-2"2'-0" OR 2'-6"SEE INTERIOR ELEVATIONSS.S. DOOR PULLS
4" LIGHT VALANCE - SEE ELECTRICAL DWGS FOR
LIGHT FIXTURE
SCRIBE AND CAULK CONTIN. BY GENERAL CONTRACTOR
FINISHED END PANEL WHERE APPLICABLE
PLASTIC LAMINATE ON ALL EXPOSED SURFACES
ADJUSTABLE SHELF (MELAMINE)
LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES
W/METAL PINS TO RECEIVE HORIZONTAL SHELF
P. LAM. SOFFIT ABOVE CABINETRY AS SPECIFIED ON
INTERIOR ELEVATIONS. FIRE TREATED WOOD
FRAMING AS REQUIRED6"TYP.FINISHED CEILING
EL. = SEE R.C.P.
UPPER CABINET W/ LIGHT VALANCE
SCALE: 1" = 1'-0"
2
A201
3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL
EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE
B/O SOFFIT
EL. = 7'-0"2'-0" OR 2'-6"SEE INTERIOR ELEVATIONSS.S. DOOR PULLS
SCRIBE AND CAULK CONTIN. BY GENERAL CONTRACTOR
PLASTIC LAMINATE ON ALL EXPOSED SURFACES
ADJUSTABLE SHELF (MELAMINE)
LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES
W/METAL PINS TO RECEIVE HORIZONTAL SHELF
FINISHED CEILING
EL. = SEE R.C.P.
UPPER CABINET
SCALE: 1" = 1'-0"
3
A201
3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL
EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE
FINISHED FLOOR3'-0"112"6"2'-1"
4" BACKSPLASH
4"312"
BASE - SEE ROOM FINISH SCHEDULE
1"4"END SPLASH AT WALL
EQ.EQ.
ȭ
SINK CABINET BASE
SCALE: 1" = 1'-0"
7
A201
SINK
SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER - SEE DETAIL
1/A501, ROOM FINISH SCHEDULE, AND
MILLWORK NOTE #22
3/4" PARTICLE BOARD, PLASTIC LAMINATE
ON ALL EXPOSED SURFACES - SEE ROOM
FINISH SCHEDULE
SCRIBE AND CAULK CONTINUOUS BY
GENERAL CONTRACTOR
DOOR/ DRAWER PULL- SEE MILLWORK
NOTES
NOTE: COUNTER SHALL BE SOLID SURFACE WHEN
OCCURRING AT SINK LOCATION
CABINET BASE
SCALE: 1" = 1'-0"
6
A201
4" BACKSPLASH SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER - SEE DETAIL
1/A501, ROOM FINISH SCHEDULE, &
MILLWORK NOTE #22
SCRIBE AND CAULK CONTINUOUS BY GENERAL
CONTRACTOR
FINISHED FLOOR
BRUSHED CHROME DOOR / DRAWER PULL
ADJUSTABLE SHELF
BASE PER ROOM FINISH SCHEDULE
NOTE: COUNTER SHALL BE SOLID SURFACE WHEN
OCCURRING AT SINK LOCATION
LINE BORE SYSTEM @ 1-1/4" O.C. BOTH
SIDES TO RECEIVE HORIZONTAL SHELF
3/4" PARTICLE BOARD; PLASTIC LAMINATE
ON ALL EXPOSED SURFACES - SEE ROOM
FINISH SCHEDULE
3'-0" SEE ELEVATION112"6"2'-1" SEE PLAN
4"1" TYP.4"312"
FINISHED FLOOR3'-0"112"(2) ADJUSTABLE SHELVES (MELAMINE)4"312"
SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER (SEE DETAIL
1/A501) - SEE ROOM FINISH SCHEDULE AND
MILLWORK NOTE #22
BASE - SEE ROOM FINISH SCHEDULE
1"
1'-6"
LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES
W/METAL PINS TO RECEIVE HORIZONTAL
SHELF
S.S. RECESSED PULL - SEE MILLWORK
NOTES
CAM LOCK AT EACH CABINET DOOR PAIR
(TYP.) - SEE MILLWORK NOTES5'-0"ȭ FLAT SCREEN TV (O.F.C.I.) & ASSOCIATED TV
WALL BRACKET WITH ADJUSTABLE ARM
(C.F.C.I.)
1"
ELEC./CATV WALL OUTLETS - SEE ELECTRICAL
DRAWINGS
LOCATE ALL ELEC./CATV WALL OUTLETS
BEHIND SCREEN - SEE ELECTRICAL
DRAWINGS
PLASTIC GROMMETS
3" DIA. (TYP.)
DISPLAY CABINET
SCALE: 1" = 1'-0"
16
A201
3/4" PARTICLE BOARD; PLASTIC LAMINATE
ON ALL EXPOSED SURFACES - SEE ROOM
FINISH SCHEDULE
FULL-HEIGHT STORAGE CABINET
SCALE: 1" = 1'-0"
9
A201
FINISHED FLOOR4"31
2"7'-0"S.S. DOOR PULLS
ADJUSTABLE SHELVES; PLASTIC
LAMINATE ON ALL EXPOSED SURFACES
BASE PER SCHEDULE
PLASTIC LAMINATE ON PLYWOOD DOOR -
4 HINGES EACH LEAF
LINE BORE SYSTEM @ 1-1/4" O.C. BOTH
SIDES W/METAL PINS TO RECEIVE
HORIZONTAL SHELVES
CAMLOCK AT EACH CABINET DOOR PAIR IF
SHOWN ON INTERIOR ELEVATIONS - SEE
MILLWORK NOTES
3/4" PARTICLE BOARD; PLASTIC LAMINATE
ON ALL EXPOSED SURFACES - SEE ROOM
FINISH SCHEDULE
DOOR/ DRAWER PULL- SEE MILLWORK
NOTES
FINISHED FLOOR
REFRIGERATOR
(N.I.C.)3'-0"112"2'-1"
4" BACKSPLASH SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER - SEE ROOM FINISH
SCHEDULE AND MILLWORK NOTE #224"1" TYP.
BASE - SEE ROOM FINISH SCHEDULE
NOTE: COUNTER SHALL BE SOLID SURFACE WHEN
OCCURRING AT SINK LOCATION
CABINET BASE - U.C. REFRIGERATOR
SCALE: 1" = 1'-0"
12
A201
FINISHED END PANEL BEYOND; PLASTIC
LAMINATE ON ALL EXPOSED SURFACES -
SEE ROOM FINISH SCHEDULE
SCRIBE AND CAULK CONTINUOUS BY GENERAL
CONTRACTOR
FINISHED FLOOR3'-0"112"4" BACKSPLASH
S.S. DRAWER PULL
4"312"
BASE - SEE ROOM FINISH SCHEDULE4"EQ.EQ1" TYP.
FILE DRAWER
FILE DRAWER
(FULL HEIGHT)
(FULL HEIGHT)
END SPLASH AT WALL
PROVIDE HANGING FILE INSERT AT ALL FILE
CABINET DRAWERS (TYP.)
NOTE: COUNTER SHALL BE SOLID SURFACE WHEN
OCCURRING AT SINK LOCATION
CABINET BASE
SCALE: 1" = 1'-0"
17
A201
3/4" PARTICLE BOARD; PLASTIC LAMINATE ON
ALL EXPOSED SURFACES - SEE ROOM FINISH
SCHEDULE
SCRIBE AND CAULK CONTINUOUS BY
GENERAL CONTRACTOR
SOLID SURFACE COUNTERTOP; MARINE
GRADE PLYWOOD SUBSTRATE AT ENTIRE
UNDERSIDE OF COUNTER (SEE DETAIL
5/A501) - SEE ROOM FINISH SCHEDULE AND
MILLWORK NOTE #22
1'-6"
CLEAR CAULK
(CONTINUOUS)
ALTERNATE NO 1:
UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK
IN CONFERENCE ROOM #109 (NEW CASEWORK BY
OWNER); SEE SHEET A101 AND OTHER SHEETS AS
MAY REFERENCE THE SCOPE OF WORK.
ALTERNATE NO. 1:
SEE DETAIL 16/A501 FOR
DESCRIPTION
ALTERNATE 2:
SEE DETAIL 9/A501 FOR
ALTERNATE DESCRIPTION
ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN DELETE NEW CASEWORK IN COPY AREA
#105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE
THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT
ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION.
ALTERNATE NO. 2:
SEE DETAIL 9/A501 FOR
DESCRIPTION
P. LAM. SOFFIT ABOVE CABINETRY AS
SPECIFIED ON INTERIOR ELEVATIONS.
FIRE TREATED WOOD FRAMING AS
REQUIRED
1'-0"6"TYP.EXISTING CLEAN OUT AT WALL TO REMAIN
1'-2"6"TYP.METAL STUD BRACING @4'-0" O.C.
TO UNDERSIDE OF STRUCTURE
ABOVE (TYP.)
5/8" GYPSUM BOARD TYPE "X" ON
3-5/8" METAL STUDS @16" O.C. (TYP.)
METAL CORNER BEAD (TYP.)
SOFFIT
EL. = SEE R.C.P.
CEILING
EL. = SEE R.C.P.
"J" BEAD TO FINISH ROUGH
DRYWALL ENDS (TYP.)
GYPSUM SOFFIT DETAIL
SCALE: 1-1/2" = 1'-0"
18
A102 6"TYP.RECESSED DOWN LIGHT FIXTURE- SEE
ELECTRICAL DRAWINGS714"734"714"
SEE R.C.P.SEE R.C.P.
3/4" PARTICLE BOARD; PLASTIC
LAMINATE ON ALL EXPOSED
SURFACES (SEE ROOM FINISH
SCHEDULE) ON 6" METAL
STUDS @16" O.C. (TYP.)
3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL
EXPOSED SURFACES (SEE ROOM FINISH SCHEDULE)
ON 3-5/8" METAL STUDS @16" O.C. (TYP.)
EXISTING CONST.
EL. = EXISTING
CEILING
EL. = SEE R.C.P.
SOFFIT
EL. = SEE R.C.P.
SOFFIT DETAIL
SCALE: 1-1/2" = 1'-0"
19
A102
1/2" SOLID SURFACE COUNTERTOP WITH 1/4"
RADIUS EASED EDGE - SEE ROOM FINISH
SCHEDULE
1/2" SOLID SURFACE COUNTERTOP (3 LAYERS
GLUED TOGETHER)
NOSING DETAIL- SOLID SURFACE
SCALE: 6"=1'-0"
1
A501
1"112"MARINE-GRADE PLYWOOD SUBSTRATE AT
ENTIRE UNDERSIDE OF COUNTER - SEE
ROOM FINISH SCHEDULE
DETAILS
A501
BW
SEAL:
MARK DATE ISSUE
- 05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/5/2017 8:55 AM
DOOR SCHEDULE
MARK LBLMATL
DOOR
SIZEELEV HDWR
DOOR FRAME
LBLMATLTRANSITIONJAMB
DETAILLFSGLAZHEAD REMARKS
101 -ALUM.3'-0"x 7'-0"x 1-3/4"C 1/4" T -1 11/A601 1
HARDWARE SCHEDULE
DOOR NOTES
ABBREVIATIONS
DOORDR
HOLLOW METALHM
INSULATED HOLLOW METALIHM
KICKPLATE (HEIGHT")K(12)
MTL.METAL
MIN MINERAL CORE
PTD.PAINTED
SCW SOLID CORE WOOD
S.S.STAINLESS STEEL
STL.STEEL
TI TEMPERED INSULATED
V.I.F.VERIFY IN FIELD
WD.WOOD
ALUMINUMALUM
T TEMPERED
1/4" WG 1/4" WIRE GLASS
1/4" T 1/4" TEMPERED GLASS
1" IG 1" INSULATED GLASS
ANODIZED ALUMINUMAA
(SEE DOOR NOTES)1. ALL DOOR HANDLES SHALL BE OF LEVER TYPE MEETING CURRENT ADA STANDARDS, (AS
NOTED IN THE HARDWARE SCHEDULE). DOOR HANDLES TO ROOMS CONSTITUTING A HAZARD
(ELECTRICAL ROOMS, MECHANICAL ROOMS, SOILED UTILITY ROOMS, ETC.) SHALL BE LEVER TYPE
WITH A KNURLED FINISH ON THE GRIP SURFACE.
2. ALL DOOR LEVERS SHALL REMAIN NON-RIGID AT LOCKED CONDITION, EXCEPT AS NOTED.
3. ALL LOCKSETS & LATCHSETS SHALL BE OF MORTISE DESIGN.
4. ALL HARDWARE FINISH SHALL BE BRUSHED STAINLESS STL. (US32D)
5. ALL PRODUCTS SPECIFIED ON AN 'OR EQUAL' BASIS UNLESS OTHERWISE NOTED.
6. PROVIDE REQUIRED POWER SUPPLY SYSTEMS FOR OPERATING ALL ELECTROMAGNETIC
LOCKS, ELECTROMECHANICAL LOCKS, ELECTRIC STRIKES, & MARLOK ELECTRONIC CYLINDER
SYSTEMS. COORD. REQUIREMENTS W/E.C.
7. ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, & ELECTRIC STRIKES SHALL BE
OF THE 'FAIL SAFE' DESIGN, UNLOCKING WHEN THE FIRE ALARM IS ACTIVATED OR ELECTRICAL
POWER IS INTERRUPTED.
8. ALL STAINLESS STEEL KICKPLATES SHALL BE 2" LESS THAN DOOR WIDTH x 12" HIGH (TYPICAL -
U.O.N.) AND SHALL BE MOUNTED 1" FROM THE BOTTOM OF THE DOOR; SEE SPECIFICATION.
9. ALL HOLLOW METAL FRAMES SHALL BE SHOP WELDED UNLESS NOTED OTHERWISE.
10. SPECIES OF ALL DOORS SHALL BE MAPLE; SEE SPECIFICATION FOR ADDITIONAL
INFORMATION.
KAWNEER 350 MEDIUM STILE DOOR
WINDOW SCHEDULE
MARKR. O. SIZE
ELEVDETAIL
HEAD REMARKSTYPEJAMBSILL
SLIDING WINDOW
SYSTEM- MAPLE TRIM
FIXED WINDOW-
H.M. TRIM
W1
W2
4'-0"W x 4'-2"H
2'-0"W x 4'-2"H
14/A601
15/A601
14/A601 17/A601
15/A601 SIM.
1/4" TEMPERED GLASS
1/4" TEMPERED GLASS
3.1-1/2 PAIR BUTT HINGES, BALL BEARING
1 - PASSAGE LATCHSET WITH LEVER HANDLES
1 - DOOR STOP, WALL OR FLOOR MOUNT
1 - SET DOOR MUTES
10.1-1/2 PAIR BUTT HINGES, BALL BEARING
1 - PASSAGE LATCHSET WITH PUSH BAR INTERIOR, NO TRIM EXTERIOR
1 - DOOR CLOSER
1 - SET DOOR MUTES
11.1-1/2 PAIR BUTT HINGES, BALL BEARING
1 - ENTRANCE LOCKSET WITH PUSH BAR INTERIOR
1 - DOOR CLOSER
1 - SET DOOR MUTES
1.1-1/2 PAIR BUTT HINGES, BALL BEARING
1 - OFFICE LOCKSET WITH LEVER HANDLES
1 - DOOR STOP, WALL OR FLOOR MOUNT
1 - SET DOOR MUTES
103 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 1 -
104 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 1 -
106 -ALUM./GL3'-0"x 7'-0"x 1-3/4"D 1" IG -1 ALUM.11 EXTERIOR DR @ LOCATION OF EXISTING WINDOW (MODIFY
AS REQD). MATCH EXISTING EXTERIOR DOORS.
109 -GL/ALUM.3'-0"x 8'-0"x 1-3/4"W3 1/2" T -1 -3 FRAMELESS GLASS (BASE BID; SEE ALTERNATES)
110 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 6 -
ALUM. / GLASS
STOREFRONT
SYSTEM
W3 12'-0"W x 7'-0"H 18/A601 19/A601 1/4" TEMPERED GLASS
W4 RELOCATED EXTERIOR WINDOW
11/A601
11/A601 11/A601
11/A601 11/A601
11/A601 11/A601 16B/A601
16A / A601
16A / A601
16A / A601
18 / A602
12 / A601ETRETR
3 - PAIR BUTT HINGES, BALL BEARING
2 - SERVICE LATCHSET WITH LEVER HANDLES
2 - DOOR STOPS
2 - SET DOOR MUTES
6.
15/A601
18/A601
ETR ETR (FIXED EXTERIOR
WINDOW)
8/A602
ALUM.
WINDOW ELEVATIONS
DOOR ELEVATIONS
B SEE SCHED.2"TYP.2"
TYP.
5"x20" GLASS VISION PANEL IN
PAINTED H.M. FRAME
SEE
SCHED.
SEE
SCHED.
SEE
SCHED.
A C10"6"
TYP.312"
TYP.
2"
TYP.SEE SCHED.2"
TYP.2"TYP.2"TYP.SEE SCHED.2"
TYP.
2"
TYP.
1/4" TEMPERED GLASS IN
CLEAR ANOD. ALUM. FRAME2"
TYP.2'-10"4'-0"
W14'-2"W24'-2"2'-10"W3
109
SEE
SCHED.
D SEE SCHED.2"
TYP.2"TYP.2"
TYP.2"TYP.2'-0"
11'-10"
INSULATED GLASS @ EXTERIOR
DOOR
7'-10"312" TYP.10"312"
TYP.312" TYP.10"W3 109
11'-10"7'-10"BASE BID ALTERNATE NO. 4
ALTERNATE NO. 4:
UNDER ALTERNATE NO. 4, DELETE THE
GLASS WINDOW WALL AT CONFERENCE
ROOM #109, AND PROVIDE AND INSTALL, IN
ITS PLACE, AN ALUMINUM AND GLASS
STOREFRONT SYSTEM (KAWNEER TRI-FAB
450 WITH A KAWNEER 190 ENTRANCE
DOOR, OR EQUAL); SEE SHEET A601 AND
SHEET A602.
FULL LIGHT MONOLITHIC
GLASS DOOR, TEMPERED,
W/C.R. LAURENCE PATCH
FITTINGS
2
A602
6
A602
9
A602
1
A602
3
A602
4
A602
7
A602
8
A602
18
A601
18
A601
19
A601
20
A601
SEE FLOOR PLAN FOR WALL TYPE
SHIM AS REQUIRED
CAULK AROUND PERIMETER (BOTH SIDES)
HOLLOW METAL FRAME (PAINT)
1/4" TEMPERED SAFETY GLASS TOP HUNG
SLIDING WINDOW SYSTEM
SLIDING WINDOW HEAD DETAIL
SCALE: 1-1/2" = 1'-0"
14
A601
WAITING
AREA
RECEPTION
AREA
NOTE:
PROVIDE NYLON GUIDES, SLIDING GLASS, DOOR LOCK
WITH KEY, AND STICK ON FINGER PULL
WAITING
AREA
RECEPTION
AREA
SEE FLOOR PLAN FOR WALL TYPE
WOOD BLOCKING AS REQUIRED
1/4" TEMPERED GLASS TOP HUNG SLIDING
WINDOW SYSTEM
SLIDING WINDOW SILL DETAIL
SCALE: 1-1/2" = 1'-0"
17
A601
HOLLOW METAL FRAME (PAINT PER FINISH
SCHEDULE)
NYLON GUIDES
NOTE:
PROVIDE NYLON GUIDES, SLIDING GLASS, DOOR LOCK
WITH KEY, AND STICK ON FINGER PULL
HOLLOW METAL FRAME - PAINT; SEE SPEC.
(TYP.)
CAULK CONT. (BOTH SIDES)
2x WOOD BLOCKING (FIRE -RETARDANT)
SEE FLOOR PLAN FOR WALL TYPE
12"
TYP.2"12"WALL ANCHORS & BASE CLIPS
DOOR - SEE DOOR SCHEDULE
DOOR HEAD / JAMB DETAIL
SCALE: 3" = 1'-0"
11
A601
FIXED WINDOW HEAD / JAMB DETAIL
SCALE: 3" = 1'-0"
15
A601 2"12"
TYP.
HOLLOW METAL FRAME - SEE SPEC.
PAINT (TYP.)
2x WOOD BLOCKING (FIRE TREATED)
SEE FLOOR PLAN FOR WALL TYPE
CAULK CONT. (BOTH SIDES)
1/4" SAFETY GLASS
RUBBER GASKET (TYP.)
GLASS STOP
FOUNDATION WALL
SWEEP & CONT. WEATHERSTRIPPING (TYP.)
THERMALLY - BROKEN ANODIZED ALUMINUM
THRESHOLD
INSULATED ALUM./ GLASS DOOR; SEE DOOR
SCHEDULE
CAULK CONT. - BOTH SIDES (TYP.)
OUTSIDE
INSIDE
12"MAX.COMPRESSIBLE FILLER AND CAULK
EXTERIOR DOOR SILL DETAIL
SCALE: 3" = 1'-0"
12
A601
T.O. LANDING
EL. =
2"
CAULK AND BACKER ROD
AROUND PERIMETER BOTH SIDES
(TYP.)
CLEAR ANODIZED ALUMINUM
STOREFRONT SYSTEM
2"
1/4" TEMPERED SAFETY GLASS
2x WOOD BLOCKING (FIRE -
RETARDANT)
SEE FLOOR PLAN FOR WALL
TYPE
412"1/4" TEMPERED SAFETY GLASS
2"1/4" TEMPERED SAFETY GLASS
SHIM AS REQUIRED
CLEAR ANODIZED ALUMINUM
STOREFRONT SYSTEM
CAULK AND BACKER ROD
AROUND PERIMETER BOTH SIDES
(TYP.)
SHIM AS REQ'D
CLEAR ANODIZED ALUMINUM
STOREFRONT SYSTEM
412"41
2"
41
2"
SHIM AS REQUIRED (TYP.)
STOREFRONT SYSTEM STOREFRONT SYSTEM STOREFRONT SYSTEM
WINDOW HEAD/JAMB DETAIL
SCALE: 3" = 1'-0"
18
A601
WINDOW SILL DETAIL
SCALE: 3" = 1'-0"
19
A601
WINDOW MULLION DETAIL
SCALE: 3" = 1'-0"
20
A601
CARPET - SEE ROOM
FINISH SCHEDULE 1/2"MAXIMUMUNDERCUTFLOORING TRANSITION CENTERED ON DOOR, NO
TRANSITION STRIP - CONTRACTOR SHALL PROVIDE A
STRAIGHT EVEN CUT AT TRANSITION FROM CARPET TO
RESILIENT FLOORING
CL
DOOR (SHOWN IN CLOSED
POSITION) - SEE DOOR
SCHEDULE; SEE SPEC.
(TYP.)
RESILIENT FLOORING - SEE
ROOM FINISH SCHEDULE
DOOR TRANSITION DETAIL
SCALE: 6" = 1'-0"
16B
A601
CARPET - SEE ROOM
FINISH SCHEDULE1/2"MAXIMUMUNDERCUTCARPET - SEE ROOM
FINISH SCHEDULE
CL
DOOR (SHOWN IN CLOSED POSITION) - SEE
DOOR SCHEDULE; SEE SPEC. (TYP.)
DOOR TRANSITION DETAIL
SCALE: 6" = 1'-0"
16A
A601
DOOR & WINDOW
SCHEDULES AND DETAILS
A601
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 5:01 PM
3/8" [9]11/16" [17]
1" [26]1 3/16" [30]DAYLITE OPENING
EU0FRAMED6MSA
EU0FP6MBL
EU0CLIPD6MSA
EU0RG6MBL
FRAME DIMENSION
1/2" [12] THICK
GLASS
9/16"
[14]
1 3/16" [30]11/16" [17]
1 7/8" [47]DAYLITE OPENING
EU0FRAMED6MSA
EU0FP6MBL
EU0CLIPD6MSA
EU0RG6MBL
1/2" [12] THICK
GLASS
DAYLITE OPENING
EU0BASISD6MSA
EU0DJ6MBL
DOOR OPENING5/8"
[16]
DOOR FRAME
9/16" [14]
1/4" [6]
1 3/16" [30]DAYLITE OPENING
DOOR OPENING 5/8"
[16]
DOOR FRAME
9/16" [14]
3/16" [5]
FRAME DIMENSION
9/16"
[14]
DAYLITE OPENING DAYLITE OPENING
1/8" [3]
1/2" [12] THICK
GLASS1 3/16" [30]1 3/16" [30]1 7/8" [48]EU0BASISD6MSA
EU0DJ6MBL 1 7/8" [48]1/2" [12] THICK
GLASS
1/2" [12] THICK
GLASS
NET DOOR SIZE
NET DOOR SIZE
EU0LKSSA
EU0LHSA
EU0HSSA
SIDELITE HEAD DETAIL
SCALE: 6" = 1'-0"
1
A601
SIDELITE SILL DETAIL
SCALE: 6" = 1'-0"
2
A601
SWING IN DOOR HEAD DETAIL
SCALE: 6" = 1'-0"
3
A601
SWING IN DOOR SILL DETAIL
SCALE: 6" = 1'-0"
4
A601
SIDELITE JAMB DETAIL
SCALE: 6" = 1'-0"
6
A601
SIDELITE GLASS JOINT DETAIL
SCALE: 6" = 1'-0"
7
A601
SIDELITE/ SWING IN DOOR JAMB DETAIL
SCALE: 6" = 1'-0"
8
A601
SWING IN DOOR JAMB DETAIL
SCALE: 6" = 1'-0"
9
A601
MANUFACTURER'S
ACOUSTICAL SEAL BETWEEN
ALL MONOLITHIC GLASS
PANELS (TYPICAL)
ACOUSTICAL GLASS WALL &
DOOR DETAILS (BASE BID)
A602
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 5:02 PM
PAINTPAINTSTAIN & VARNISHCARPETRESILIENT FLOORINGFLOOR TILERESILIENT BASEPAINTFLOOR BASE WALLS DOOR
REMARKS
WESTSOUTH
PAINTEASTNORTH
PAINTROOM NAMEROOM#
ROOM FINISH SCHEDULE
ENTRANCE VESTIBULE B1 P2 P2 P2 P2 S P1
B1 S P1P2P2P2
C1101
102
103
104
105
106
107
108
109
110
WAITING ROOM
ADMIN OFFICE P2 P2 P2
P2 P2P2
P2 P2 P2
P2 P2 P2P2
P2 P2 P2 P2
P2 P2 P2P2
P2 P3 P2 P2
P2 P2 P2P2
S P1
S P1
S P1
S P1
S P1
S P1
S P1
S P1
ATTORNEY OFFICE
COPY AREA
HALL
STAFF BREAK ROOM
TOILET ROOM
CONFERENCE ROOM
FILES / STORAGE ROOM
TRIM
ABBREVIATIONS
GENERAL FINISH NOTES
A.IN ALL AREAS WHERE DEMOLITION OCCURS, PATCH TO MATCH EXISTING/ NEW FINISHES AS
SCHEDULED.
B.SEE REFLECTED CEILING PLAN FOR CEILING TYPES AND FINISHES.
CG CORNER GUARD
CPT.CARPET
E.T.R.EXISTING TO REMAIN
LVT LUXURY VINYL TILE
M.E.MATCH EXISTING
MOD.MODIFY EXISTING AS REQUIRED
MTL.METAL
PTD.PAINTED
P.T.M.PATCH TO MATCH EXISTING
T.B.D.TO BE DETERMINED
U.N.O. UNLESS NOTED OTHERWISE
V.I.F.VERIFY IN FIELD
WD. WOOD
FINISHES BY BLDG OWNER
C2
C2
C2
C2
C2
V1
T1
C2
PAINT AND WALL, DOOR, & TRIM FINISHES
P1 - PAINT 1 (TRIM):
MANUFACTURER: BENJAMIN MOORE
FINISH: ADVANCE, SEMI-GLOSS
COLOR: SIMPLY WHITE #2143-70
P2 - PAINT 2 (TYPICAL WALLS):
MANUFACTURER: SHERWIN WILLIAMS
FINISH: EGGSHELL
COLOR: SOFTER TAN #SW-6141
P3 - PAINT 3 (ACCENT):
MANUFACTURER: BENJAMIN MOORE
FINISH: EGGSHELL
COLOR: SCHOONER #AF-420
1.ALL NEW WOOD VENEER DOORS SHALL BE
MAPLE VENEER U.N.O. FINISH SHALL BE 2
COATS OF CLEAR, SATIN FINISH
POLYURETHANE. SEE DOOR SCHEDULE.
2.PAINT ALL PAINTED TRIM IN PROJECT AREA P1.
3.UNDERSIDES AND ALL EXPOSED FACES OF
ALL GYPSUM SOFFITS (SEE R.C.P.) SHALL BE
PAINTED P2 U.N.O.
4.ALL GYPSUM BOARD CEILINGS (SEE R.C.P.)
SHALL BE PAINTED BENJAMIN MOORE, CEILING
WHITE U.N.O.
MILLWORK AND SURFACING
PL1 - PLASTIC LAMINATE 1 (VERTICAL/
CABINETRY):
MANUFACTURER: WILSONART
COLOR: FONTHILL PEAR #10745-60
FINISH: MATTE
SS1 - SOLID SURFACE 1:
MANUFACTURER: CORIAN
COLOR: SORREL
1.ALL COUNTERTOPS WITH SINKS SHALL BE
SOLID SURFACE SS1. SINKS SHALL BE
STAINLESS STEEL UNDERMOUNTS; SEE
PLUMBING DRAWINGS.
2.SEE MILLWORK NOTES, SHEET A501, FOR
CABINETRY HARDWARE INFORMATION.
3.SOLID SURFACE WALL CAPS AT HALF WALLS
SHALL BE SS1. SEE WALL TYPE 2/A101.
4.COLOR OF METAL SUPPORT BRACKETS AT
MILLWORK COUNTERTOPS SHALL BE BLACK.
SEE MILLWORK NOTES.
FLOORING, BASE, AND TILE
FLOORING:
C1 - WALK-OFF CARPET:
MANUFACTURER: SHAW
STYLE/ SERIES: PORTAL #5T035
SIZE: 24" x 24"
COLOR: EBONY #34500
INSTALLATION METHOD: MONOLITHIC
C2 - CARPET TILE:
MANUFACTURER: J+J INVISION
STYLE/ SERIES: INCEPTION NEUTRAL PLANK #7019
SIZE: 18" X 36"
COLOR: GENERATE #1742
INSTALLATION METHOD: ASHLAR
V1 - VINYL TILE
MANUFACTURER: BOLYU
STYLE/ SERIES: MINERAL
SIZE: 18" X 36"
COLOR: URBAN GREY #BLVEL-002
INSTALLATION METHOD: MONOLITHIC
_______________________________________________
TRANSITIONS:
TS1 - TRANSITION STRIP:
MANUFACTURER: JOHNSONITE
COLOR: MOONROCK #29
_______________________________________________
WALL BASE:
B1 - VINYL BASE:
MANUFACTURER: JOHNSONITE
HEIGHT: 4"
STYLE/ SERIES: TRADITIONAL WALL BASE
x CARPET AREAS- STRAIGHT/
xRESILIENT FLOORING AREAS- COVE
COLOR: BLACK #40
_______________________________________________
TILE:
T1 - PORCELAIN TILE:
BY BUILDING OWNER
1.CENTER ALL FLOOR TILES IN ROOM WHERE
FEASIBLE.
2.INSTALL TRANSITION STRIPS WHERE
REQUIRED UNDER DOORS DIRECTLY UNDER
THE CLOSED DOOR. SEE DETAILS ON DOOR
SCHEDULE.
3.PROVIDE TRANSITION STRIPS WHERE
REQUIRED WHERE NEW FLOORING ABUTS
EXISTING FLOORING SURFACES TO REMAIN.
6. PROVIDE TRANSITION STRIPS WHERE
REQUIRED BY DIFFERENT FINISHED FLOOR
HEIGHTS/ THICKNESS.
7.ALL RESILIENT BASE SHALL BE ROLLED
GOODS. USE LONGEST LENGTHS POSSIBLE
AND MINIMIZE SEAMS.
8.RESILIENT BASE: USE STRAIGHT BASE FOR
CARPET CONDITION; COVE BASE FOR
RESILIENT FLOORING CONDITION.
WALL PROTECTION
CHAIR RAILS: SEE DETAIL 17/AF601
MANUFACTURER: JOHNSONITE
STYLE / SERIES: MILLWORK CONTOURED
CHAIR RAIL
COLOR: BLACK #40
CORNER GUARDS: SEE DETAIL 16/AF601
MANUFACTURER: INPRO CORPORATION
STYLE / SERIES&/($5q
FRP PANEL: SEE DETAIL 18/AF601
MANUFACTUER: MARLITE
STYLE / SERIES: STANDARD FRP, PEBBLED
COLOR: MATCH WALL COLOR
1.TERMINATE CHAIR RAILS TO PROVIDE 6"
MINIMUM CLEARANCE BETWEEN RAIL AND
ANY OPENINGS OR CORNERS.
2.INSTALL CORNER GUARDS WHERE SHOWN ON
FINISHES FLOOR PLAN, AND AT ANY OTHER
HIGH-TRAFFIC/ HIGH-IMPACT CORNERS AS
REQUIRED.
3.INSTALL FRP PANEL AT SERVICE SINK; MATCH
WIDTH OF MANUFACTURER'S OPTIONAL WALL
GUARD x HEIGHT TO COVER FAUCET AND
OTHER ACCESSORIES PLUS 4"; PROVIDE AND
INSTALL 7/16" EDGE MOULDING (TYPICAL)
MATERIALS NOTES
MATERIALS NOTESMATERIALSNOTES
MATERIALS NOTES
CHAIR RAIL
P3
P2
V1
P3
P3B1
B1
B1
B1
B1
B1
B1
B1 SEE NOTE 3.
WAITING
102
218 SF
N
OFFICE
N
FRIDGE
CONFERENCE
ROOM
109
214 SF
FILES/ STORAGE
110
115 SF
ATTORNEY
OFFICE
104
153 SF
ADMIN
OFFICE
103
103 SF
ENTRANCE
VESTIBULE
101
42 SF
COAT RACK
COPY
AREA
105
82 SF
HALL
106
83 SF
STAFF
BREAK
107
53 SF
TOILET
108
51 SF
ALTERNATE NO. 1:
UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK
IN CONFERENCE ROOM #109 (NEW CASEWORK BY
OWNER); SEE SHEET A101 AND OTHER SHEETS AS
MAY REFERENCE THE SCOPE OF WORK.
ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK
IN COPY AREA #105 (NEW CASEWORK BY OWNER);
SEE SHEET A101 AND OTHER SHEETS AS MAY
REFERENCE THE SCOPE OF WORK. DELETE TWO (2)
UNDER-CABINET LIGHTS AND PLASTIC LAMINATE
SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW
SUSPENDED ACOUSTICAL CEILING TO PARTITION.
ALTERNATE NO. 4:
UNDER ALTERNATE NO. 4, DELETE THE GLASS
WINDOW WALL AT CONFERENCE ROOM #109, AND
PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM
AND GLASS STOREFRONT SYSTEM (KAWNEER
TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR,
OR EQUAL); SEE SHEET A601 AND SHEET A602.
FINISHES FLOOR PLAN
SCALE: 1/4" = 1'-0"
NEW WINDOW SHADES AT ALL EXTERIOR WINDOWS-
SEE SPEC.
CG
16
AF601
CGCG
NEW CHAIR RAIL- SEE FINISH SCHEDULEC1C2
C2V1C2T1
C2V1
F.R.P. PANEL BEHIND MOP SINK- SEE DETAIL 18/AF601
INPRO CORP CLEAR CORNER GUARD
(USE ONLY FOR LOW IMPACT AREAS/ OCCUPANCIES)
CORNER GUARD DETAIL- IPC CLEAR
SCALE: 6" = 1'-0"
16
AF601
CLEAR CORNER GUARD
.050" [.127mm] THICK
34"SELF-TAPPING
NAILSCREWS
CLEAR CORNER GUARD
.100" [2.54mm] THICK
PAN HEAD SELF-TAPPING
NAILSCREWS
212"118"PAN HEAD
SELF-TAPPING
NAILSCREWS
CLEAR CORNER
GUARD .075"
[1.90mm] THICK
q%8//126(q
q q
q$1'q352),/(6$9$,/$%/(
IN 2 1/2" WING SIZE ONLY)
CHAIR RAIL DETAIL
SCALE: 6" = 1'-0"
17
AF601
CL
SEE FLOOR PLAN FOR
WALL TYPE
V.I.F.JOHNSONITE MILLWORK CONTOURED CHAIR
RAIL - SEE FINISH SCHEDULE. INSTALL PER
MANUFACTURER'S SPECIFICATIONS.
COORDINATE MOUNTING HEIGHT WITH OWNER
AFTER FURNITURE SELECTION.
TOP EDGE - M370 1
FRP - PVC TRIMMARLITE
PANEL
SUBWALL
M370 EDGE TRIM
CEILING LINE OR
TOP OF ELEVATION
SEALANT
332"716"14"
BOTTOM EDGE - M370 2
FRP - PVC TRIMMARLITE
ADHESIVE
PANEL
SUBWALL
M370 EDGE TRIM
SEALANT
FLOOR LINE14"716"332"
VERTICAL EDGE - M370 3
FRP - PVC TRIM
SUBWALL
PANEL
SEALANT
M370 EDGE TRIM
ADHESIVE
14"716"332"FRP PANEL DETAIL
SCALE: N.T.S.
18
AF601
FINISH SCHEDULE
AF601
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:50 PM
ALL MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHOWN IS DIAGRAMMATIC AND
INTENDED TO SHOW THE GENERAL SCOPE OF EACH TRADE.
MECHANICAL NOTES
THE GENERAL PLUMBING NOTES AND SUMMARY OF WORK, ABOVE, ARE INTENDED TO
DESCRIBE THE SCOPE OF WORK TO BE EXECUTED BY THE PLUMBING CONTRACTOR. THE
CONTRACT DRAWINGS DETAIL THE GENERAL SCOPE AND PERFORMANCE REQUIREMENTS OF
THE CONTRACT. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL DESIGN
AND INSTALLATION OF HIS / HER SCOPE IN ACCORDANCE WITH ALL APPLICABLE CODES.
1. FIXTURES AND TRIM AS NOTED SHALL BE "ACCESSIBLE" AND SHALL BE INSTALLED TO ADA/ANSI A117 REQUIREMENTS.
2. INSTALL TRUEBRO INC. MODEL #102, HANDI LAV-GUARD PROTECTOR ON THE HOT, COLD, AND DRAIN PIPING UNDER FIXTURE.
3. PROVIDE ISOLATION VALVES AT ALL FIXTURES (TYPICAL).
4. PROVIDE WATER HAMMER ARRESTORS AT FIXTURES (TYPICAL)
5. SEE FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO EACH FIXTURE.
6. FIXTURES PROVIDED BY BUILDING OWNER AND INSTALLED BY CONTRACTOR.
REMARKS:
SYMBOL
PLUMBING FIXTURE SCHEDULE
MANUFACTURER MODEL NO.DESCRIPTION ACCESSORIES REMARKS
BUILDING OWNER'S STANDARD
E. L. MUSTEE
NOT USED
BUILDING OWNER'S STANDARD
ELKAY DROP-IN STAINLESS STEEL SINK BASINLR-1919 CHICAGO MODEL # 895-319ABCP, CHROME PLATED
GOOSENECK FAUCET, 6" WRIST BLADE HANDLES, 0.5
GPM AERATOR, CHROME PLATED GRID DRAIN
LEGEND
HOT WATER PIPING
COLD WATER PIPING
SANITARY SEWER PIPING
PLUMBING VENT ABOVE CEILING
HW
CW
S
V
PLUMBING CONTRACTOR SHALL ROUTE NEW VENT TO VTR LOCATED IN COORDINATION WITH G.C.
GENERAL PLUMBING NOTES
A. WASTE PIPING
PROVIDE SHOCK ABSORBERS AS REQUIRED; PROVIDE VALVES, UNIONS, AND COUPLINGS TO
ISOLATE EQUIPMENT AND SUPPLY OR DRAIN SYSTEM.
PROVIDE SHUT OFF VALVES AT EACH FIXTURE OR PIECE OF EQUIPMENT.
ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES. THIS SHALL
INCLUDE, BUT SHALL NOT BE LIMITED TO, THE COMMONWEALTH OF MASSACHUSETTS STATE
PLUMBING CODE.
COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING PLUMBING FIXTURES AND
EQUIPMENT SUPPLIES.
IT IS IN THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A FIRST
CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE AND/OR DEVICES
USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN
ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF
THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE
CONTRACTOR AS PART OF HIS TOTAL WORK.
PLUMBING CONTRACTOR SHALL PAY ALL FEES AND SECURE ALL PERMITS AND LICENSES
APPLICABLE TO THIS SECTION OF THE WORK.
REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE ALL PLUMBING
FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED.
VERIFY LOCATION OF WATER SERVICE AND THE LOCATION/INVERTS OF SANITARY/STORM PIPING
PRIOR TO INSTALLATION.
COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE,
ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING
SHALL BE HELD EITHER ABOVE OR BELOW HVAC DUCTWORK AS COORDINATED WITH THE HVAC
CONTRACTOR.
ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A PERIOD OF ONE
YEAR FROM ACCEPTANCE BY THE OWNER.
ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT.
PLUMBING CONTRACTOR IS REQUIRED TO VERIFY ALL INVERTS PRIOR TO ANY PIPING
INSTALLATION. INVERT NUMBERS (IF PROVIDED) WERE OBTAINED FROM PREVIOUS CONSTRUCTION
DOCUMENTS AND PREVIOUS SURVEYS. THESE NUMBERS WERE NOT "AS-BUILT" NUMBERS. NOTIFY
ARCHITECT OF ANY DISCREPANCIES.
TEST ALL PIPING SYSTEMS - DISINFECT HOT AND COLD WATER PIPING.
SUPPORT ALL PIPING WITH CLEVIS TYPE HANGERS AS REQUIRED BY CODE; USE NO STRAPS.
1. BELOW FLOOR - CAST IRON, NO HUB OR COMPRESSION FITTING.
B. VENT PIPING
1. ABOVE GRADE OR FLOOR - DWV COPPER, CAST IRON, NO HUB. OR AS APPROVED BY LOCAL
PLUMBING INSPECTOR.
C. WATER SUPPLY PIPING
1. ABOVE GRADE OR FLOOR - TYPE L COPPER.
2. PROVIDE 95/5 TIN-ANTIMONY SOLDER JOINTS.
- CONNECT NEW SINKS TO PLUMBING SYSTEMS:
HW - 1/2", CW - 1/2", S - 2", V - 2"
- CONNECT NEW FLOOR SINK TO EXISTING PLUMBING SYSTEMS:
HW - 1/2", CW - 1/2", S - 2", V - 2"
- CONNECT NEW TOILET TO PLUMBING SYSTEMS:
CW - 1/2", S - 4", V - 4"
FIXTURE CONNECTION SCHEDULE
LAVATORY: ACCESSIBLE, VITREOUS CHINA
WALL-MOUNTED LAVATORY SIMILAR TO
KOHLER MORNINGSIDE
WATER CLOSET: ACCESSIBLE, VITREOUS
CHINA , TANK-TYPE, FLOOR-MOUNTED WATER
CLOSET
63M ONE-PIECE MOLDED, HIGH-IMPACT RESISTANT
STRUCTURAL FIBERGLASS BASIN (24"x24") W/S.S.
STRAINER & INTEGRALLY MOLDED DRAIN & SEAL
E. L. MUSTEE MODEL # 67.24C 20 GAUGE #304 S.S.
DURAGUARD WALLGUARD, 12" HIGH; OPTIONAL SEAL
AS REQUIRED
SUMMARY OF WORK:
SEE FIXTURE CONNECTION SCHEDULE ABOVE.
WAITING
102
218 SF
CONFERENCE
ROOM
109
214 SF
FILES/ STORAGE
110
115 SF
ATTORNEY
OFFICE
104
153 SF
ADMIN
OFFICE
103
103 SF
ENTRANCE
VESTIBULE
101
42 SF
COPY
AREA
105
82 SF
HALL
106
83 SF
STAFF
BREAK
107
53 SF
TOILET
108
51 SF
P
P
F
F
F
PLUMBING PLAN
SCALE: 1/4" = 1'-0"
INSTALL SINK IN MILLWORK AT EXISTING
PIPING TERMINATIONS; MODIFY PIPING AS
REQUIRED FOR NEW WORK; SEE
PLUMBING CONNECTION SCHEDULE
INSTALL TOILET AT EXISTING PLUMBING
PIPING TERMINATIONS; MODIFY PIPING AS
REQUIRED FOR NEW WORK; SEE
PLUMBING CONNECTION SCHEDULE
CWCWCWS S S S S SHWHWCAP EXISTING SANITARY IN ACCORDANCE
W/APPLICABLE CODES AND STANDARDS
SSHW HW HW HW HW
INSTALL FLOOR SINK AND ASSOCIATED
PLUMBING PIPING; MODIFY EXISTING
PIPING AS REQUIRED FOR NEW WORK;
SEE PLUMBING CONNECTION SCHEDULE
EXISTING CLEAN OUT AT WALL TO REMAIN;
CONTRACTOR TO PROVIDE COVER AND
FLANGE/TRIM. COORDINATE WITH
CABINETRY AND PROVIDE ACCESS AS
REQUIRED.
EXISTING CLEAN OUT AT WALL TO REMAIN;
CONTRACTOR TO PROVIDE COVER AND
FLANGE/TRIM. COORDINATE WITH
FINISHES - SEE FINISH SCHEDULE
INSTALL LAVORATORY AT EXISTING
PLUMBING PIPING TERMINATIONS; MODIFY
PIPING AS REQUIRED FOR NEW WORK;
SEE PLUMBING CONNECTION SCHEDULE
PLUMBING PLAN,
DETAILS & SCHEDULES
P101
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:55 PM
AIR CHANGES PER HOURRELATIVE PRESSURETOTAL CFMROOM AIR BALANCING SCHEDULE
ROOM #ROOM NAME REMARKS
TO ADJACENT SPACESRELATIVE HUMIDITYPARAMETERS
ROOM VOLUME (CF)102 WAITING ROOM
108
ADMIN. OFFICE
110
107 STAFF BREAK
4SQ. FT.4
4
103
TOILET 10
FILES / STORAGE 4
NEG.
101 ENTRANCE VESTIBULE 4
ATTORNEY OFFICE 4104
COPY AREA 4105
106 HALL 4
CONFERENCE ROOM 4109
41
220
103
153
82
83
53
53
214
115
380
2035
953
1,416
759
768
491
491
1712
1064
25
136
64
95
51
52
33
82
115
71
ALL MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHOWN IS DIAGRAMMATIC AND
INTENDED TO SHOW THE GENERAL SCOPE OF EACH TRADE.
MECHANICAL NOTES
THE GENERAL HVAC NOTES AND SUMMARY OF WORK, ABOVE, ARE INTENDED TO DESCRIBE
THE SCOPE OF WORK TO BE EXECUTED BY THE MECHANICAL CONTRACTOR. THE CONTRACT
DRAWINGS DETAIL THE GENERAL SCOPE AND PERFORMANCE REQUIREMENTS OF THE
CONTRACT. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL DESIGN AND
INSTALLATION OF HIS / HER SCOPE IN ACCORDANCE WITH ALL APPLICABLE CODES.
LEGEND
CEILING SUPPLY DIFFUSER
CEILING RETURN OR EXHAUST GRILLE
HVAC NOTES
THE SYSTEM DESCRIBED HEREIN IS INTENDED TO DESCRIBE THE GENERAL INTENT OF THE
MODIFICATIONS TO EXISTING SYSTEMS. THE ACTUAL METHODS OF ACHIEVING THIS DESIRED
INTENT SHALL REMAIN THE RESPONSIBILITY OF THE HVAC CONTRACTOR AND THE GENERAL
CONTRACTOR IN CONSULTATION WITH THE BUILDING OWNER:
1.FURNISH AND INSTALL A HEATING, VENTILATING AND AIR CONDITIONING SYSTEM AS SHOWN
ON THE PLANS IN WORKING ORDER TO THE OWNER USING NEW AND/OR EXISTING EQUIPMENT
AND MODIFIED EXISTING DUCTWORK AND CONTROLS.
2.ALL EQUIPMENT AND WORKMANSHIP TO BE GUARANTEED BY CONTRACTOR FOR ONE YEAR
FROM DATE OF FINAL PAYMENT.
3.SUBMIT AT LEAST THREE (3) COPIES OF SHOP DRAWINGS ON ALL EQUIPMENT TO ARCHITECT /
ENGINEER.
4.ALL EQUIPMENT AND INSTALLATIONS SHALL CONFORM TO STATE AND LOCAL CODES. INSTALL
PER MANUFACTURER'S RECOMMENDATIONS.
GALVANIZED SHEET METAL DUCTS: UP TO 12" 26 GA;
13" TO 30" 24 GA;
ELBOWS AND TRANSFORMATION PIECES: 2 GAUGES HEAVIER.
5.
BALANCE AIR AND WATER SIDE OF SYSTEM PER APPLICABLE CODE(S) AND STANDARDS.6.
CEILING DIFFUSERS: MATCH EXISTING UNLESS OTHERWISE NOTED ON CONTRACT DRAWINGS.7.
CEILING RETURN AIR GRILLES: MATCH EXISTING UNLESS OTHERWISE NOTED ON CONTRACT
DRAWINGS.
8.
INSULATE ALL PIPING WITH 1" ASJ FIBERGLASS WITH VAPOR BARRIER. SEAL ANDS. ZESTON PVC
AT ELBOWS.
9.
TEMPERATURE CONTROLS:
- MODIFY EXISTING SYSTEM FOR NEW LAYOUT.
- ALL CONTROL WIRING (LOW AMD LINE VOLTAGE) BY HVAC CONTRACTOR.
10.
AIR BALANCING:
- RE-BALANCE COMPLETED SYSTEM TO ACHIEVE AIR FLOW IN CONFORMANCE WITH APPLICABLE
CODES AND STANDARDS (DEFINING CODE ASSUMED TO BE IMC 2009).
11.
POS.
POS.
POS.
POS.
POS.
POS.
POS.
POS.
POS.
SUMMARY OF WORK:
WAITING
102
218 SF
CONFERENCE
ROOM
109
214 SF
FILES/ STORAGE
110
115 SF
ATTORNEY
OFFICE
104
153 SF
ADMIN
OFFICE
103
103 SF
ENTRANCE
VESTIBULE
101
42 SF
COPY
AREA
105
82 SF
HALL
106
83 SF
STAFF
BREAK
107
53 SF
TOILET
108
51 SF
F S
F S
2
2
B B
ETR
ETR
A (NL)
B B
B
B B
BB
BBB
B B B
BB
B
B
C C C C
CCC
C
C C C
C
C C C
A (NL)A (NL)
1
1
1
1
1
1
1
1
H H
H (NL)
FF
SIM
ETR
HVAC PLAN
SCALE: 1/4" = 1'-0"
HVAC PLAN
M101
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for:
PROJECT:5/4/2017 4:54 PM
LEGEND
HOME RUN TO EXISTING PANEL - ELECTRICAL CONTRACTOR TO BALANCE PANEL
BASED ON NEW LOADS
SINGLE POLE SWITCH
PHONE SYSTEM OUTLET
FIRE ALARM PULL STATION
FIRE ALARM HORN/STROBE
FLUSH CEILING MOUNTED SPEAKERS
CEILING - MOUNTED EXIT SIGN
DUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATED
COMPUTER OUTLET
QUADRUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATED
COMPUTER/PHONE OUTLET
2'-0" UNDERCABINET LIGHTING FIXTURE
4'-0" UNDERCABINET LIGHTING FIXTURE
ELECTRICAL NOTES
LIGHT FIXTURE
CEILING MOUNTED EXIT SIGN / EMERGENCY LIGHT
GENERAL NOTES
A. THE PLANS ARE DIAGRAMMATIC IN NATURE AND THEIR INTENT IS TO SHOW THE BASIC
REQUIREMENTS OF THE SYSTEM. THE INSTALLER SHALL FURNISH ALL MATERIALS, FIXTURES,
WIRING, DEVICES, SUPPORT, DISCONNECT SWITCHES, AND OTHER REQUIRED EQUIPMENT NOT
SPECIFICALLY INDICATED HEREIN, AND LABOR FOR A COMPLETE AND OPERATING SYSTEM AS
SPECIFIED HEREIN. THE INSTALLER IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ANY
NECESSARY PERMITS AND APPROVALS, AND ANY OTHER CHARGES OR FEES.
B. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE (NFPA 70), AND THE THE MASSACHUSETTS ELECTRIC CODE.
C. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE (1) YEAR
FROM THE DATE OF SUBSTANTIAL COMPLETION.
WIRING2.
A. ALL WIRING SHALL MATCH EXISTING BUILDING STANDARD UNLESS SPECIFICALLY INDICATED
OTHERWISE. ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND THE
MASSACHUSETTS ELECTRIC CODE. ALL WIRING TO BE RUN CONCEALED. IN MOST CASE NEW
LIGHTS SHOWN ARE TO BE CONNECTED TO EXISTING CIRCUITS IN THE AREA.
1. WIRING FOR CIRCUITS INDICATED TO BE CONNECTED TO THE EMERGENCY SYSTEM (IF
REQUIRED/SHOWN) SHALL BE KEPT ENTIRELY INDEPENDENT OF OTHER WIRING AND
SHALL NOT ENTER THE SAME RACEWAY, BOX, CABINET, ETC. WITH OTHER WIRING. A
SEPARATE WIRE AND CONDUIT SYSTEM IS REQUIRED FOR THE EMERGENCY SYSTEM
IDENTIFIED AS AN EMERGENCY SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC
CODE.
3.RECEPTACLES
A. ALL DUPLEX AND/OR QUADRUPLEX RECEPTACLES TO BE MOUNTED 18" ABOVE FINISH FLOOR
UNLESS INDICATED OTHERWISE. RECEPTACLES TO BE COMMERCIAL GRADE RATED FOR 20
AMPS 120V.
4.SWITCHES
A. LIGHTING SWITCHES SHALL BE RATED FOR 20 AMP 120/277 VOLTS.
B. INSTALL WALL SWITCHES 48 INCHES (ON CENTER) ABOVE FLOOR, OFF POSITION DOWN.
6.SUPPORT REQUIREMENTS
A. LIGHT FIXTURES TO BE SUPPORTED INDEPENDENT OF THE CEILING GRID SYSTEM. THEY SHALL
BE SUPPORTED FROM THE BUILDING STRUCTURE WITH JACK CHAINS.
8.FIRESTOPPING
A. THE INTEGRITY OF FIRE-RATED WALLS AND FLOORS, WHERE PENETRATIONS ARE MADE FOR
THE PASSAGE OF CONDUIT, CABLES, ETC., MUST BE MAINTAINED.
1. ALL PENETRATIONS MUST BE SLEEVED AND FIRE STOPPED WITH MATERIALS THAT ARE UL
CLASSIFIED AND FACTORY MUTUAL APPROVED FOR USE IN APPLICABLE RATED ASSEMBLY.
9.PANEL BALANCING
A. THE ELECTRICAL CONTRACTOR SHALL BALANCE ALL CIRCUITS AS REQUIRED AT ALL PANELS.
5 DATA / TELEPHONE OUTLET
A. ALL DATA / TELEPHONE OUTLETS TO CONSIST OF FLUSH OUTLET BOX WITH CONCEALED 3/4"
METAL CONDUIT RUN TO ABOVE SUSPENDED CEILING.
B. TELEPHONE / DATA WIRING TO BE ACCOMPLISHED BY OWNERS CONTRACTOR.
D. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF
EQUIPMENT. ITEMS WHICH ARE NOT SPECIFICALLY LOCATED BY DIMENSION ON THE
ARCHITECTURAL PLANS SHOULD BE COORDINATED WITH THE ARCHITECT.
E. ALL EQUIPMENT LISTED ON THE DRAWING IS SPECIFIED AS "OR APPROVED EQUAL" UNLESS
INDICATED OTHERWISE. THE CONTRACTOR SHALL PROVIDE SUBMITTALS FOR ANY EQUIPMENT
DIFFERENT FROM WHAT IS LISTED ON THE DRAWINGS FOR APPROVAL BY THE ARCHITECT
PRIOR TO INSTALLATION. FOR GENERAL EQUIPMENT WHICH IS NOT LISTED ON THE DRAWINGS,
SUBMITTALS ARE REQUIRED.
F. FOR EQUIPMENT FURNISHED BY "OTHERS", THE ELECTRICAL CONTRACTOR SHALL RUN THE
POWER LINES TO EQUIPMENT DISCONNECT SWITCHES AND MAKE FINAL CONNECTION TO
EQUIPMENT UNLESS INDICATED OTHERWISE. THE CONTROLS FOR SAID EQUIPMENT SHALL BE
THE RESPONSIBILITY OF "OTHERS" UNLESS NOTED OTHERWISE. COORDINATE LOADS WITH
OTHER TRADES AND VERIFY SAME.
G.CONTRACTOR TO COORDINATE I.T. REQUIREMENTS WITH OWNER.
MARKINGS
A. MARK EXTERIOR OF ALL JUNCTION BOXES IN THE ELECTRICAL WIRING SYSTEM TO INDICATE
CIRCUIT NUMBER AND PANEL DESIGNATION OF ALL CIRCUITS.
7.
18"
18"
P
F
3" RECESSED LED LIGHTING FIXTURE
1" RECESSED LED LIGHTING FIXTURE
LIGHT FIXTURE
FIRE ALARM STROBEF
1. BIDS SHALL BE BASED ON THE LIGHTING FIXTURE SCHEDULE AND SPECIFICATIONS.
2. ALL FIXTURES SHALL BE UL LISTED.
3. HIGH FREQUENCY, ELECTRONIC TYPE BALLAST SHALL BE USED WITH ALL FLUORESCENT LAMPS
WHEN POSSIBLE. ALL FLUORESCENT BALLAST SHALL HAVE A MIN. POWER FACTOR OF 0.9. A CLASS
"A" RATING WHERE POSSIBLE, BE UL LISTED AND BE ON THE NORTHEAST UTILITIES LIST OF
APPROVED BALLASTS. FLUORESCENT BALLAST USED IN EXTERIOR FIXTURES SHALL HAVE A MIN.
67$57,1*7(03(5$785(2)q)
4. ALL INCANDESCENT LAMPS DESIGNED FOR 120V OPERATION SHALL BE EXTENDED SERVICE LIFE TIME.
5. ALL NECESSARY MOUNTING HARDWARE, HANGERS, BRACKETS, RAILS, YOKES, STEMS, CHAINS, ETC.,
SHALL BE FURNISHED AND INSTALLED.
6. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFIC DETAILS, ARRANGEMENT, MOUNTING HEIGHTS,
CEILING CONSTRUCTIONS, ETC. ALL COLORS AND FINISHES SHALL BE VERIFIED BY THE ARCHITECT.
7. FIXTURES SHALL BE SEISMICALLY SUPPORTED AS REQUIRED BY THE COMMONWEALTH OF
MASSACHUSETTS BUILDING CODE.
8. WIRE ALL BATTERY PACK UNITS (I.E. EXIT SIGNS AND EMERGENCY UNITS) TO LINE SIDE OF LOCAL
LIGHTING BRANCH CIRCUIT.
LIGHTING FIXTURE NOTES
FIRE ALARM SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR
F S
HF
ELECTRICAL FIXTURE SCHEDULE
A
TYPE
B
C
D
F
24"X48" RECESSED LED FIXTURE, EXISTING BUILDING STANDARD
24"X24" RECESSED LED FIXTURE, LITHONIA MODEL 2VTL2-33L-ADP-D36-LP850, 120V; 20 GAUGE STEEL HOUSING,
SINGLE CLEAR ACRYLIC DIFFUSER; INTEGRAL LED DRIVER
3" RECESSED LED DOWNLIGHT, CREATIVE LIGHTING SYSTEMS MODEL EDL-NC_15W_LPD_1116; INTEGRAL LED
DRIVER
NOT USED
2' LED UNDERCABINET LIGHT FIXTURE, STEEL HOUSING, ACRYLIC DIFFUSER; WHITE HOUSING, 120 V
G
2 HEADED COMBINATION EMERGENCY / EXIT SIGN CONNECTED TO UNSWITCHED CIRCUIT FEEDING ADJACENT
LIGHTS.H
EXIT LIGHT - TO MATCH BUILDING STANDARD (SINGLE FACE 120V). PROVIDE SEPARATE CIRCUIT FOR EXIT LIGHTS
ETR - EXISTING TO REMAIN
VIF - VERIFY IN FIELD
RL -RELOCATE EXISTING DEVICE
NL -NEW LOCATION FOR EXISTING DEVICE
WAITING
102
218 SF
CONFERENCE
ROOM
109
214 SF
FILES/ STORAGE
110
115 SF
ATTORNEY
OFFICE
104
153 SF
ADMIN
OFFICE
103
103 SF
ENTRANCE
VESTIBULE
101
42 SF
COPY
AREA
105
82 SF
HALL
106
83 SF
E.P.STAFF
BREAK
107
53 SF
TOILET
108
51 SF
P
P
F
F
F
F S
F S
ALTERNATE NO. 2:
UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK
IN COPY AREA #105 (NEW CASEWORK BY OWNER);
SEE SHEET A101 AND OTHER SHEETS AS MAY
REFERENCE THE SCOPE OF WORK. DELETE TWO (2)
UNDER-CABINET LIGHTS AND PLASTIC LAMINATE
SOFFIT ABOVE CASEWORK, AND EXTEND
SUSPENDED ACOUSTICAL CEILING SYSTEM TO
PARTITION.
BASE BID:
LIGHTING AS SHOWN; UNDER ALTERNATE NO. 3,
DELETE ELEVEN (11) RECESSED LED FIXTURES IN
CONFERENCE ROOM #109, AND INSTALL SIX (6) NEW
2X2 LED RECESSED TROFFERS; SEE DETAIL 19/A102
BELOW.
B B
ETR
ETR
A (NL)
B B
B
B B
BB
BBB
B B B
BB
B
B
C C C C
CCC
C
C C C
C
C C C
A (NL)A (NL)
H H
H (NL)
FF
SIM
ETR
ELECTRICAL LIGHTING PLAN
SCALE: 1/4" = 1'-0"
WAITING
102
CONFERENCE
ROOM
109
FILES/ STORAGE
110
ATTORNEY
OFFICE
104
ADMIN
OFFICE
103
ENTRANCE
VESTIBULE
101
COAT RACK
REF.(U.C.)MICROTV
COPY
AREA
105
HALL
106
E.P.STAFF
BREAK
107
TOILET
108
P
P
F
F
F
ELECTRICAL DEVICE PLAN
SCALE: 1/4" = 1'-0"
18"
18"
18"
18"
18"
18"
ETR
V.I.F.COORDINATE REQUIRED
OUTLET TYPES ANDMOUNTING
HEIGHT FOR T.V. WITH OWNER.
ENSURE T.V. SCREEN HIDES
ALL OUTLETS.18"DEDICATED 44"18"18"18"
18"
18"
V.I.F.18"18"
V.I.F.
18"44"3
3
UNDER- CABINET LIGHTS
(SWITCH INTEGRATED WITH FIXTURE)
3
3
18"
18"ETRETRETR
ETR
ETR (44" GFCI)
RELOCATED PULL STATION AT
NEW EGRESS DOOR; COMPLY
WITH NFPA 101: LIFE SAFETY
CODERELOCATED COMBINATION
EMERGENCY LIGHT AND EXIT
SIGN AT NEW EGRESS DOOR;
COMPLY WITH NFPA 101: LIFE
SAFETY CODE
F S
F S
ETR
ETR
F S
NL
F S
NL
CONFERENCE
ROOM
109
214 SF
B B
B B
B B
ELECTRICAL LIGHTING PLAN - ALTERNATE NO. 3
SCALE: 1/4" = 1'-0"
ALTERNATE NO. 3:
UNDER ALTERNATE NO. 3, DELETE ELEVEN (11) RECESSED LED
FIXTURES IN CONFERENCE ROOM #109, AND INSTALL SIX (6) NEW
2X2 LED RECESSED TROFFERS AS SHOWN ON SHEET A102:
REFLECTED CEILING PLAN AND SHEET E101: ELECTRICAL POWER
AND LIGHTING PLAN; SEE OTHER SHEETS AS MAY REFERENCE
THE SCOPE OF WORK.
REMOVE EXISTING PULL
STATION AND RELOCATE TO
NEW EGRESS DOOR
REMOVE COMBINATION
EMERGENCY LIGHT AND EXIT
SIGN AND RELOCATE TO NEW
EGRESS DOOR
COORDINATE REQUIRED
OUTLET TYPES ANDMOUNTING
HEIGHT FOR T.V. WITH OWNER.
ENSURE T.V. SCREEN HIDES
ALL OUTLETS.
44" GFCI
ETR
ETR
GFCIREMOVE WALL SWITCH AND
PROVIDE BLANK PLATE TO
MATCH BLDG STANDARD
REWORK EXISTING ELEC
OUTLET TO MAKE GFCI
COMPLAINT48"48"
ELECTRICAL LIGHTING PLAN
& ELECTRICAL DEVICE PLAN
E101
BW
SEAL:
MARK DATE ISSUE
-05/04/2017 PERMIT SET
PROJECT NO:
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
DATE:
COPYRIGHT:
16-095
DJH
DJH
04/21/2017
SHEET TITLE:
CONSULTANT:
64 GOTHIC STREET, SUITE 1
NORTHAMPTON, MA 01060
T 413.585.1512 F 413.586.7945
www.haiarchitecture.com
H AI Architecture, Inc.
Corliss Law Office
100 Main Street
Florence, MA 01062
Renovation for: