Loading...
16-095CORLISS LAW OFFICE FLORENCE, MASSACHUSETTS 01062 100 MAIN STREET Renovation for: INDEX TO DRAWINGSALTERNATESGENERAL NOTES CONSTRUCTION CLASSIFICATION OCCUPANCY CLASSIFICATION APPLICABLE CODES & STANDARDS BUILDING CODES AND STANDARDS 1. MASSACHUSETTS STATE BUILDING CODE (780 CMR), 8TH EDITION 2. MASSACHUSETTS ELECTRIC CODE (527 CMR), NEC 2017 WITH MASSACHUSETTS AMENDMENTS 3. NFPA 101 LIFE SAFETY CODE (2015 EDITION) 4. MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATIONS (521 CMR), 2006 EDITION 5. MASSACHUSETTS STATE PLUMBING CODE (248 CMR) B - BUSINESS TYPE V-A 1.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALL WORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL SUB-CONTRACTORS ARE IDENTIFIED IN A SUMMARY OF WORK ON PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS AS PART OF THIS SET OF CONTRACT DRAWINGS. 2.THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA. 3.THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLY WITH ALL SUBCONTRACTORS AND THE OWNER. 4.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP. 5.THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES. 6.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE, 8TH EDITION, WITH ALL OF ITS REFERENCED PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS. 7.IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE ( NFPA 101, 2015 ED.). 8.THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THE OWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE. 9.THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK. 10.THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED. GI001 TITLE SHEET GI002 INFORMATION SHEET A101 FLOOR PLAN, WALL TYPES & DETAILS A102 REFLECTED CEILING PLAN A201 INTERIOR ELEVATIONS A501 DETAILS A601 DOOR & WINDOW SCHEDULES AND DETAILS A602 GLASS WINDOW WALL (BASE BID) AF601 FINISH SCHEDULE P101 PLUMBING PLAN, DETAILS & SCHEDULE M101 HVAC PLAN & SCHEDULE E101 ELECTRICAL LIGHTING PLAN & ELECTRICAL DEVICE PLAN 1.ALTERNATE NO. 1: UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. 2.ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION. 3.ALTERNATE NO. 3: UNDER ALTERNATE NO. 3, DELETE ELEVEN (11) RECESSED LED FIXTURES IN CONFERENCE ROOM #109, AND INSTALL SIX (6) NEW 2X2 LED RECESSED TROFFERS AS SHOWN ON SHEET A102: REFLECTED CEILING PLAN AND SHEET E101: ELECTRICAL POWER AND LIGHTING PLAN; SEE OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. 4.ALTERNATE NO. 4: UNDER ALTERNATE NO. 4, DELETE THE GLASS WINDOW WALL AT CONFERENCE ROOM #109, AND PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM AND GLASS STOREFRONT SYSTEM (KAWNEER TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR, OR EQUAL); SEE SHEET A601 AND SHEET A602.TITLE SHEET GI001 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:28 PM ZONING DISTRICT: PRINCIPAL USE: ZONING RESTRICTIONS RELATIVE TO USE: NOT APPLICABLE PARKING REQUIREMENTS: NOT APPLICABLE ADDITIONAL REQUIREMENTS: NOT APPLICABLE INTERIOR ELEVATION DESIGNATION DETAIL IDENTIFICATION ELEVATION LETTER SECTION DESIGNATION ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN SECTION DESIGNATION ROOM AND NAME NUMBER ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN ON SHEET WHERE SECTION IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION DOOR NUMBER KEY NOTE WALL TYPE HEIGHT MARK DETAIL DESIGNATION ON SHEET WHERE DETAIL IS TAKEN; SHEET NUMBER WHERE DRAWN DETAIL DESIGNATION SECTION DESIGNATION FIXTURE AND MISC. ACCESSORIES HEIGHTS 15"-48"MIN. MAX.17"-25"36" MAX.TO SPOUT OUTLET27" MIN.KNEE CLEARANCE48"MAX48"MAX.Per NFPA 72 the lens of the strobe shall be no less than 80" and no greater than 96" AFF. When clg heights don't allow for a min. height of 80", strobes shall be mounted within 6" of clg 17" MIN.34" MAX.TO RIMINSULATE ALL PLUMBING W/ TRUEBRO LAVATORY GUARD OR EQUAL FINISH FLOOR 15"-48"MIN MAX48"48" LINE FINISH FLOOR LINE The highest operable part of telephone, including dial, handset and coin deposit slots shall be within the reach ranges specified in ABA Section 30815"MINAccessible storage spaces shall be within at least one of the reach ranges specified in ABA Sections 308 29"MIN.27"MIN.40" MAX. TO BTMEDGE OF REFLECTINGSURFACEHIGHEST OPERABLE PART HIGHEST OPERABLE PART HIGHEST OPERABLE PART 15" - 42" DEPENDENTON FORWARD OR SIDE REACH36"x48" CLR. FLR. SPACE FIRE HORN AND LIGHT FIRE EXTINGUISHER CABINET PUBLIC TELEPHONE (ELEVATION) 30"x48" CLR. FLOOR SPACE FOR FORWARD APPROACH PUBLIC TELEPHONE (PLAN) CLOTHES HOOK/ROD DUPLEX RECEPTACLE 30"x48" CLR. FLOOR SPACE LAVATORY (ELEV.)LAVATORY FORWARD APPROACH (PLAN) MIRROR DRINKING FOUNTAIN (PARALLEL APPROACH) FREE STANDING OR BUILT-IN UNITS DRINKING FOUNTAIN (FORWARD APPROACH) WALL & POST MOUNTED CANTILEVERED UNITS ACCESSIBLE DRINKING FOUNTAIN (ELEV.) MIN. SHOWER CONFIGURATION PLAN SOAP DISPENSER NAPKIN/TAMPON VENDOR PAPER TOWEL DISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARM PULL STATION42"-48"OPTIONAL POST OR BASE 4'-0"MAX.8" MIN.30"x48" CLR. FLOOR SPACE 30"x48" CLR. FLOOR SPACE6" MAX. TOE CLEARANCE 6" MAX. TOE CLEARANCE 15" - 42" DEPENDENTON FORWARD OR SIDE REACH15" - 42" DEPENDENTON FORWARD OR SIDE REACHNOTE: CONTROLS OF OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN UFAS SECTION 4.2.5 & 4.2.6 HIGHEST OPERABLE PART FOR FORWARDOR SIDE REACHFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEE PLAN FORUNOBSTRUCTEDSIDE ORFORWARD REACH9" MIN.TOECLEARANCE17"MIN.5" MAX. 5" MAX. SPOUT LOCATION SPOUT LOCATION 15" MIN. 15" MIN.9" MIN.TOE CLEARANCE8" MIN. KNEE CLEARANCE MIRROR -REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES AND TURNING SPACES SHALL BE PERMITTED TO OVERLAP. -DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. 1 A101 A B C D 2 A102 1 A101 CONFERENCE ROOM 1005 201 2 CEILING HEIGHT EL. = 100'-0" 36 A101 EXIT REQUIREMENTS: OCCUPANCY LOAD: 1,173 SF @ 100 SF / OCCUPANT = 12 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1.1) MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS): MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS): NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1009.1, NOT LESS THAN 44") REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP B): 2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1021.1) CORRIDORS: 36" MIN. REQUIRED, 63" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1018.2) DOORS: 36" MIN. REQUIRED, 36" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1005.1) FEMALE TOILET 1 PER 20 OCC = 1 REQUIRED, 1 PROVIDED RAMPS: NOT APPLICABLE (SEE INTERNATIONAL BUILDING CODE 1010.5) FEMALE SINKS 1 PER 40 OCC = 1 REQUIRED, 1 PROVIDED MALE TOILET 1 PER 25 OCC = 1 REQUIRED, 1 PROVIDED MALE SINKS 1 PER 40 OCC = 1 REQUIRED, 1 PROVIDED EYE/FACE WASH (SIDE ELEV.)27" MIN.KNEE CLEARANCE36" MAX.SPRAY HEADCLEARANCE48" MAX. HEIGHTFOR FORWARD REACH30"x48" CLR. FLOOR SPACE EYE/FACE WASH (PLAN) PAPER TOWEL DISPENSER AND WASTE RECEPTACLE4'-0"MAX.HIGHEST OPERABLEPARTFOLD DOWN SEAT AS REQUIRED FRONT ELEV. BABY CHANGING STATION SIDE ELEV.PLAN48"MAXTO OPERABLEPORTION34"MAX.TO HIGHEST PART OF WORKSURFACE IN DOWN POSITION27"MIN.TO BOTTOM OF WORKSURFACE30"x48" MIN. 17" - 25" TOE CLEARANCE 30" OR WIDTH OF TABLE 48"25"OR LESS44" MAXLATCHABBREVIATIONS 33"-36"MIN. MAX.7"-9" MIN. MAX.15"-48"MIN. MAX.12" MAX.42" MIN.12" MIN.33"-36"MIN. MAX.FINISH FLOOR LINE 13-1/2" MIN. Mount on side wall closest to water closet; shall not be located behind grab bar Grab bars shall be between 1-1/4" and LQ™DQGORFDWHGFOHDU from wall 17"-19"MIN. MAX.18" TOILET TISSUE DISPENSER/HOLDER TOILET CLOSEST SIDE WALL GRAB BARS (ELEV.) TOILET REAR WALL GRAB BARS (ELEVATION) TOILET (SIDE ELEVATION) Flush controls shall be located on the open side of water closet or directly behind the toilet. TOILET (FRONT ELEVATION) URINAL (ELEVATION) URINAL (PLAN) 36" MIN. 24" MIN. OPEN SIDE 54" MIN. TRANSFER SIDE SIDE WALL 17" MAX.TO RIM44" TYP.FLUSH CONTROLSW/IN REACH RANGEABA SECTION 308CLEARANCE AT TOILET (PLAN) 5'-6" MIN.6'-0"MIN.18" 30"x48" CLR. FLOOR SPACE 6'-0" X 5'-6" MIN. CLEAR FLOOR SPACEPREFERRED LOCATION IS BELOW GRAB BAR @ 2'-0" A.F.F. TO CENTER OF DISPENSER 6" MIN.33"-36"MIN. MAX.TOILET REAR WALL GRAB BARS (ELEV.) 3'-6" MIN. 3'-0" MIN.OPEN SIDE ȭ TRANSFER SIDE SWING-UP GRAB BAR W/ INTEGRAL TOILET PAPER DISPENSER (ELEV.) CIRCULAR SPACE T-SHAPED SPACE This space shall be permitted to include knee and toe clearance complying with ABAAS Section 306 60" DIA. (MIN.)36"24"12"36"12" 60"60"This space shall be permitted to include knee and toe clearance complying with ABAAS Section 306 only at the end of the base or one arm NURSE CALL LIGHT6"EQ.EQ. CL CL NURSE CALL LIGHT; SEE ELEC. DWGS. 2'-5"3'-0"ZONING ANALYSIS CODE ANALYSIS GRAPHIC SYMBOLS ANCHOR BOLT ACOUSTICAL AIR CONDITIONER ADJACENT ABOVE FINISH FLOOR ALTERNATE ALUMINUM ANCHOR ANODIZED ARCHITECT B.L. BD. BLDG. BLK. BLKG. B.O. A.B. ACOUST. A.C. ADJ. A.F.F. ALT. ALUM. ANCH. ANOD. ARCH. BTM. BRG. BRK. BUILDING LINE BOARD BUILDING BLOCK BLOCKING BOTTOM OF BOTTOM BEARING BRICK CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CABINET CORNER GUARD CONTROL JOINT CLOSET CENTER CEILING CLEAR (DIMENSION) CONCRETE MASONRY UNIT COLUMN COMPACTED (COMPOSITION) CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CERAMIC TILE DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DETAIL DRAWINGS EAST EXTERIOR INSULATION & FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EQUAL EQUIPMENT EMERGENCY ROOM EXISTING TO REMAIN ELECTRIC WATER COOLER EXHAUST EXISTING EXPANSION EXTERIOR FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FLOOR FINISH FACE OF FINISH FACE OF FOUNDATION WALL FACE OF MASONRY FACE OF STUD FIELD VERIFY GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GENERAL GLAZE GRADE GYPSUM WALL BOARD HANDICAPPED HEIGHT HOLLOW METAL HOT WATER HEATER HEATING, VENTILATING AND AIR CONDITIONING INSIDE DIAMETER INSULATED HOLLOW METAL INSULATED STEEL INSULATION INTERIOR JANITOR JOIST JOINT KICKPLATE (HEIGHT") LAMINATE LAVATORY MASONRY MAXIMUM MECHANICAL MECHANICAL, ELECTRICAL, PLUMBING MANUFACTURER MOUNTED METAL MINERAL CORE MINIMUM MISCELLANEOUS MASONRY OPENING MULLION NORTH NATURAL NAPKIN DISPENSER NECESSARY NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FINISHED, OWNER INSTALLED OPENING OPPOSITE PROPERTY LINE PARTICLE BOARD PLASTIC LAMINATE PLASTER PAINT PAINTED PARTITION POLYVINYL CHLORIDE PLYWOOD ROOF DRAIN REFERENCE REFRIGERATOR REINFORCE REQUIRED ROUGH ROOM ROUGH OPENING SOUTH SOLID CORE WOOD SECTION SQUARE FOOT SIMILAR SURFACE MOUNTED SPECIFICATIONS STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURAL SUSPEND(ED) SYSTEM TEMPERED TOP OF TELEPHONE THICK TEMPERED INSULATED TOILET TYPICAL TOP OF FOUNDATION TOP OF WALL ELEVATION TOP OF STEEL ELEVATION TOP OF SLAB UNDER COUNTER REFRIGERATOR UNIT HEATER UNDERSIDE OF DECK UNLESS NOTED OTHERWISE URINAL VINYL BASE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD WEST WITH WITHOUT WITHIN WATER CLOSET WOOD 1/4" WIRE GLASS 1/4" TEMPERED GLASS CAB. C.F.C.I. C.G. C.J. CL. CTR. CLG. CLR. CMU COL. COMP. CONC. CONST. CONT. CONTR. C.T. D.F. DIA. DIM. DN DR. DTL. DWGS. E E.I.F.S. E.J. EL. ELEC. ELEV. EQ. EQUIP. E.R. E.T.R. E.W.C. EXH. EX. EXP. EXT. F.D. FDN. F.E. F.E.C. F.H.C. FIN. FLR. F.O.F. F.F. F.O.M. F.O.S. F.V. GA. GALV. G.C. GEN. GL. GLZ. GRD. G.W.B. H.C. HGT. H.M. H.W.H. HVAC I.D. I.H.M. I.S. INSUL. INT. JAN. JST. JT. K(12) LAM. LAV. MAS. MAX. MECH. M.E.P. MFR. MTD. MTL. MIN MIN. MISC. M.O. MULL. N NAT. N.D. NEC. N.I.C. N.T.S. O.C. O.F.C.I. O.F.O.I. OPG. OPP. P.L. PBD. PLAM. PLAS. PT. PTD. PTN. PVC PLYWD. R.D. REF. REFR. REINF. REQ'D RGH. RM. R.O. S S.C.W. SECT. SF SIM. S.M. SPEC. S.S. STD. STL. STOR. STRUCT. SUSP. SYS. T. T.O. TEL. THK. T.I. TLT. TYP. T.O.F. T.O.W. T.O.S. T.SLB. U.C.REFR. U.H. U.O.D. U.N.O. UR. V.B. V.C.T. VERT. VEST. V.I.F. W W/ W/O W/IN W.C. WD. 1/4 W.G. 1/4 T. REFLECTED CEILING PLANRCP GOVERNMENT FURNISHED PROPERTY GFP INFORMATION SHEET GI002 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:31 PM FURNITURE SHOWN ON DRAWINGS, EXCEPT CASEWORK, IS NOT INCLUDED IN THIS CONTRACT UNLESS NOTED OTHERWISE. 10. ALL DOORS AND WALLS NOT LABELED WITH A WALL TYPE OR DOOR NUMBER ARE TO BE CONSIDERED EXISTING TO REMAIN. 9. GENERAL CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL WALLS, NEW OR EXISTING, THAT ARE TO RECEIVE NEW OR EXISTING CABINETRY, SHELVING, ETC.; COORDINATE W/OWNER. 8. WHERE UTILITY AND MECHANICAL WORK IS REMOVED OR ALTERED, GENERAL CONTRACTOR IS RESPONSIBLE FOR PREPARING AND PATCHING BUILDING STRUCTURE TO MATCH NEW AND EXISTING WORK AS INDICATED ON DRAWINGS. 7. ALL WORK TO BE CONSIDERED AS NEW WORK UNLESS INDICATED AS EXISTING TO REMAIN.6. CONSTRUCT NEW INTERIOR PARTITIONS FROM FLOOR TO THE UNDERSIDE OF THE STRUCTURE ABOVE (DECK OR SLAB) UNLESS NOTED OTHERWISE; VERIFY IN FIELD. 5. REPAIR ANY IRREGULARITIES IN SURFACES INCLUDING BUT NOT LIMITED TO AREAS DISTURBED BY NEW WORK. 4. PROVIDE TEMPORARY DUST PROOFING PARTITIONS TO EFFECTIVELY SEAL OFF WORK AREAS FROM THE REST OF THE BUILDING. PROVIDE TEMPORARY DOOR IF NECESSARY. 3. 2.ANY REPAIRS, PATCHING, OR DEMOLITION INDICATED ON DRAWINGS REPRESENT THE GENERAL AREA WHERE WORK IS TO BE DONE, BUT DOES NOT NECESSARILY LIMIT THE EXTENT OF WORK. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SUCH REPAIRS, PATCHING, ETC. WHERE THEY OCCUR IN BUILDING UNDER THIS CONTRACT. 1.GENERAL CONTRACTOR MUST VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH THE WORK. GENERAL CONSTRUCTION NOTES ROOM NAME AND ROOM NUMBER DOOR NUMBER NEW WALL CONSTRUCTION EXISTING CONSTRUCTION LEGEND WALL TYPE PRIVACY CURTAIN (N.I.C.) NEW HALF WALL CONSTRUCTION (U.N.O.) ROOM NAME XXX XXX 1 NEW MILLWORK / CASEWORK WITH PLASTIC LAMINATE COUNTERTOP NEW MILLWORK / CASEWORK WITH SOLID SURFACE COUNTERTOP WAITING 102 218 SF M DN DN UP RAMP W EXISTING GAS SERVICE METER ELECTRIC SERVICE PANELS AND METERS KITCHEN OFFICE OFFICE OFFICE OFFICE OFFICE WORK STATION WORK STATION WORK STATIONSTORAGE CONFERENCE CL FRIDGE FLOOR PLAN SCALE: 1/4" = 1'-0" WORK STATION WORK STATION 5'-31316r21'-77 16" CONFERENCE ROOM 109 214 SF FILES/ STORAGE 110 115 SF14'-1178r14'-3" ATTORNEY OFFICE 104 153 SF 13'-10"11'-1" ADMIN OFFICE 103 103 SF 11'-33 4" CHECK-IN WINDOW ACOUSTICAL GLASS WALL AND DOOR SYSTEM 1'-0" MIN. CLRENTRANCE VESTIBULE 101 42 SF 7'-0" CLEAR5'-0" CLEARCOAT RACK REF.(U.C.)MICRO6'-9316rTV 5'-113 4" V.I.F. FULL-HEIGHT CABINET COPIER 4'-7"3'-4"1'-0"2'-1"3'-2" WORK COUNTER W/ UPPER CABINETS ABOVE 5'-4316rCOPY AREA 105 82 SF 2'-0" D 7 A201 C D 6 A201 A 5 A201 HALL 106 83 SF W1 W2 A B C D 1 A201 E.P. 101 109 110 103 104 1 1 1 1 1 2 4 1'-11 116" W3 6'-10"1 5'-31 2"23'-234" V.I.F.9'-1" V.I.F.12'-21516"7'-934" V.I.F.7'-4"7'-0" ALIGN 3'-6" 1'-10" ȭ ȭ 2'-1" 1'-2" 3'-6" ȭ STAFF BREAK 107 53 SF TOILET 108 51 SF 106 NEW ALUMINUM ENTRANCE DOOR WITH TRANSOM- SEE DOOR SCHEDULE; REMOVE EXISTING WINDOW WITH TRANSOM ABOVE (SALVAGE WINDOW AND TRANSOM FOR RELOCATION AS SHOWN) AND PREPARE MASONRY OPENING FOR NEW WORK. NEW LOCATION FOR SALVAGED WINDOW AND TRANSOM - SEE WINDOW SCHEDULE; REMOVE EXISTING DOOR AND TRANSOM AND PREP MASONRY OPENING FOR NEW WORK. RELOCATE EXISTING FIRE ALARM NOTIFICATION DEVICES AS REQUIRED (TYPICAL) W4 7'-0" ALIGN P P F F F B8 A201 A 3'-6" A D 11 A201 NEW RECESSED FIRE EXTINGUISHER CABINET, MODIFY EXISTING WALL AS REQUIRED TO MAINTAIN FULL CLEAR WIDTH OF HALLWAY. FURR WALL AT REAR OF FIRE EXTINGUISHER CABINET AS REQ'D.1'-6"1'-3"NEW WINDOW SHADES AT ALL EXTERIOR WINDOWS - SEE FINISHES PLAN. UPPER CABINETS ALTERNATE NO. 1: UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION. 1'-6"3'-6" (=)3'-6" (=)4'-312" ȭȭ NEW SERVICE SINK - SEE PLUMBING DRAWINGS; SAWCUT EXISTING CONCRETE SLAB FOR EXTENSION OF SANITARY PIPING TO NEW PLUMBING FIXTURE; MODIFY EXISTING WALL CONSTRUCTION TO ACCOMMODATE NEW PLUMBING PIPING (TYPICAL); INFILL CONCRETE SLAB - SEE DETAIL 18/A101 VISION PANEL ALTERNATE NO. 4: UNDER ALTERNATE NO. 4, DELETE THE GLASS WINDOW WALL AT CONFERENCE ROOM #109, AND PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM AND GLASS STOREFRONT SYSTEM (KAWNEER TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR, OR EQUAL); SEE SHEET A601 AND SHEET A602. NEW ALUMINUM ENTRANCE DOOR - SEE DOOR SCHEDULE 2'-212" ȭ 3 834"EXISTING ELECTRICAL PANEL TO REMAIN ALIGN 1 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) BATT SOUND INSULATION NON-RATED WALL BASE - SEE ROOM FINISH SCHEDULE CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS FLOOR LINE 12" H CLEAR ANODIZED ALUMINUM REVEALS FASTEN PLATE SECURELY TO FLOOR3'-6" (N.T.S.)BASE PER FINISH SCHEDULE 1/2" SOLID SURFACE CAP- SEE ROOM FINISH SCHEDULE1/4"2 HALF-HEIGHT WALL SCALE: 1" = 1'-0" NON-RATED WALL METAL CORNER BEAD (TYP.) 10 GA. WALL SUPPORT FRAMING REINFORCEMENT UNIT - 3.625" x 24" SECURED TO FLOOR WITH 1/2" ACCESSORY PLATE AND (2) 3/8" DIA. EXPANSION ANCHORS, 3-1/2" EMBEDMENT. UNITS AT ADJACENT TWO STUDS AT END OF WALL AND @32" O.C. 1/4" ALUMINUM REVEAL (ALL EXPOSED SIDES) 1/2" SOLID SURFACE CAP- SEE ROOM FINISH SCHEDULE NOTE: FASTEN ONE END OF WALL TO FULL HEIGHT WALL. PROVIDE BLOCKING AND SUPPORT AS REQUIRED 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE.2'-0" A.F.F. (N.T.S.)3 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYPSUM BOARD BATT SOUND INSULATION NON-RATED WALL BASE - SEE ROOM FINISH SCHEDULE CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS EXISTING WALL CONSTRUCTION 3-5/8" METAL STUDS @ 16" O.C. 3-5/8" METAL STUDS @ 16" O.C. 2-1/2" METAL STUDS @ 16" O.C. 4 WALL TYPE SCALE: 1" = 1'-0" FLOOR LINE 5/8" TYPE "X" GYPSUM BOARD (EACH SIDE) BATT SOUND INSULATION NON-RATED WALL BASE - SEE ROOM FINISH SCHEDULE CEILING SEE R.C.P. LINE OF STRUCTURAL DECK OR SLAB ABOVE USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL WET AREAS 3-5/8" METAL STUDS @ 16" O.C. SEE FLOOR PLAN 2'-0" TYPICAL VARIESDRILL EXISTING CONCRETE SLAB FOR NEW STEEL DOWEL EXISTING CONCRETE SLAB PLAN SECTION NEW PIPING NEW CONCRETE SLAB (4000 PSI) EXISTING CONCRETE SLAB 6" MIN. BEDDED SAND (TYPICAL) NEW CONCRETE SLAB (4000 PSI)VARIESSEE SITE COND.WATERSTOP (TYPICAL) NEW 1/2" x 8" MINIMUM STEEL DOWEL ANCHORED INTO EXISTING & NEW CONC. SLABS@ 3'-0" O.C., EACH SIDE OF TRENCH (TYPICAL) CONTRACTOR TO PROVIDE 10-MIL VAPOR BARRIER BELOW PROPOSED CONCRETE WORK AND OVERLAP EXISTING VAPOR BARRIER (12" MINIMUM) - TAPE ALL EDGES PLUMBING FLOOR PATCH DETAIL SCALE: N.T.S. - - ALIGN 2" MIN. COVER SAND OR STONE DUST (TYPICAL) SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT: FLOOR PLAN & WALLTYPES A101 BW 5/4/2017 4:38 PM ADMIN. OFFICE #103 INTERIOR ELEVATIONS SCALE: 1/4" = 1'-0" 6 A101 C D BASE PER FINISH SCHEDULE (TYP.)2'-10"4'-0" COPY AREA #105 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 5 A101 A BASE PER FINISH SCHEDULE (TYP.) PLASTIC LAMINATE SOFFIT- SEE REFLECTED CEILING PLAN 3'-0"4'-6"1" COUNTERTOP OVERHANG3'-0"7'-0"3'-0"2'-3"2'-0"2'-0"3'-3"2'-3" STAFF BREAK #107 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 7 A101 D BASE PER FINISH SCHEDULE (TYP.)2" FILLER2'-6" LIGHT VALANCE - SEE ELECTRICAL DRAWINGS 2'-6"2" FILLER FRIDGE (U.C.) 2'-6" 134r FILLER 2'-734"2'-6" 2'-6" W1 W2 4'-2"4'-2"2'-10"2" FILLER 2" FILLER 2" FILLER TRASH/ RECYCLE BIN TRASH/ RECYCLE BIN WAITING ROOM #102 INTERIOR ELEVATIONS SCALE: 1/4" = 1'-0" 1 A101 A BASE PER FINISH SCHEDULE (TYP.)2'-10"4'-0" W1 4'-2"B CONFERENCE ROOM #109 INTERIOR ELEVATIONS SCALE: 1/4" = 1'-0" 8 A101 HANDWASHING SINK - SEE PLUMBING DWGS SOAP DISPENSER @42" A.F.F. (C.F.C.I.) PAPER TOWEL DISPENSER @42" A.F.F. (C.F.C.I.) ALL EXPOSED ENDS FINISHED (TYP.)3'-0"2'-0"2'-0"8 A501 LOW WALL W/ SOLID SURFACE CAP- SEE WALLTYPES & FINISH SCHEDULE A BASE PER FINISH SCHEDULE (TYP.)3'-0"BASE PER FINISH SCHEDULE (TYP.) W3 8'-0"C 9 A501 W3 D TOILET #108 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" 11 A101 EXISTING MIRROR BY BLDG OWNER; CONTRACTOR TO INSTALL EXISTING LAVATORY BY BLDG OWNER; CONTRACTOR TO INSTALL SOAP DISPENSER @42" A.F.F. (O.F.C.I.) PAPER TOWEL DISPENSER (O.F.C.I.) 1-1/2" DIA. STAINLESS STEEL GRAB BARS (O.F.C.I.) TOILET PAPER DISPENSER @24" A.F.F. (O.F.C.I.) EXISTING WATER CLOSET BY BLDG OWNER; CONTRACTOR TO INSTALL BASE - SEE ROOM FINISH SCHEDULE 6"3'-6"1'-0"3'-6"2'-10"BASE - SEE ROOM FINISH SCHEDULE D B EXISTING PRE-FORMED INSULATING KNEE GUARD BY BLDG OWNER; CONTRACTOR TO INSTALL 1-1/2" DIA. STAINLESS STEEL GRAB BARS (O.F.C.I.)2'-10"8" 2" FILLER 2" FILLER 2 A501 3 A501 6 A501 7 A501 LOW WALL W/ SOLID SURFACE CAP- SEE WALLTYPES & FINISH SCHEDULE 12 A501 TV 3'-0"3'-0"3'-0"3'-0"2'-8" PLASTIC LAMINATE SOFFIT- SEE R.C.P. AND DETAILS BASE PER FINISH SCHEDULE (TYP.) 16 A501 17 A501 ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION. ALTERNATE NO. 1: UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEWCASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. BASE PER FINISH SCHEDULE (TYP.) B FLAT SCREEN TV (O.F.C.I.) & ASSOCIATED TV WALL BRACKET WITH ADJUSTABLE ARM (C.F.C.I.). COORDINATE HEIGHT W/ OWNER IN FIELD GYPSUM SOFFIT- SEE R.C.P. AND DETAILS 9'-0" 12'-2" 2 (OPEN TO COPY AREA) 5'-0" CLEAR TO DOOR 2 COPIER (NIC) EQ.EQ. BASE BID - SEE ALTERNATE NO. 4 BASE BID - SEE ALTERNATE NO. 4 NOTE: OWNER/CONTRACTOR TO VERIFY EXTENT OF TOILET ACCESSORIES TO BE PROVIDED BY BLDG OWNER (I.E. GRAB BARS, MIRROR, ETC.). FOR OWNER PROVIDED ITEMS CONTRACTOR WILL BE REQUIRED TO INSTALL THEM. EXISTING WALL MOUNTED FIRE ALARM HORN STROBE AND WALL MOUNTED EMERGENCY LIGHT TO REMAIN. EXISTING LIGHT SWITCH TO REMAIN. EXISTING EMERGENCY LIGHT TO REMAIN ALL EXPOSED ENDS FINISHED (TYP.) INTERIOR ELEVATIONS A201 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:44 PM 1.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE BEGINNING WORK. FABRICATE CASEWORK IN SECTIONS AS NECESSARY TO FACILITATE HANDLING AND BUILDING ENTRY. ALL SUCH CASEWORK SECTIONS TO BE JOINED WITH SPLINES AND RV #315 TITE-JOINT FASTENERS. MILLWORK NOTES 2.ALL CASEWORK AND MILLWORK FABRICATION AND MATERIALS TO EQUAL ARCHITECTURAL WOODWORK INSTITUTE QUALITY STANDARDS "CUSTOM GRADE" OR BETTER. 3.CASEWORK IS TO BE FLUSH OVERLAY CONSTRUCTION. USE SCRIBE ENDS WHERE CASEWORK IS EXPOSED. CAULK JOINTS TO ELIMINATE GAPPING BETWEEN DISSIMILAR MATERIALS, OR NEW CASEWORK AND EXISTING CONSTRUCTION (TYPICAL). USE STILES WHERE NECESSARY TO MOUNT HINGES TO ADJACENT DOORS. CAULK BACKSPLASHES TO COUNTERS, NO CAULK JOINT SHALL EXCEED 1/8". 4.ALL CASEWORK CORES TO BE 3/4" PARTICLE BOARD EXCEPT AS NOTED. 5.ALL BASE CABINETS KICKS TO BE 3/4" SOLID WOOD OR VENEER PLYWOOD. 6.ALL INTERIOR SURFACE OF EXPOSED (OPEN) CABINETS SHALL BE PLASTIC LAMINATE TO MATCH EXTERIOR OF CABINET. INTERIOR SURFACES OF UNEXPOSED (CLOSED WITH DOORS, DRAWERS, OR PANELS) SHALL BE MELAMINE (WHITE) UNLESS OTHERWISE NOTED. 8.BACKS OF PLASTIC LAMINATED SURFACES SHALL RECEIVE BALANCE SHEET. 9.CABINET BACKS - USE PREFINISHED HARDBOARD (MELAMINE, ETC) WITH COLOR TO MATCH PLASTIC LAMINATE CASEWORK. USE 1/2" HARDBOARD WITH PLASTIC LAMINATE AND BALANCE SHEET AT ALL CASEWORK BACKS THAT ARE EXPOSED. GENERAL CONTRACTOR IS TO PROVIDE BLOCKING IN WALLS FOR CASEWORK EVEN IF NOT SPECIFICALLY INDICATED ON DRAWINGS. 11. 12. CABINETRY HARDWARE: FOR ADDITIONAL INFORMATION REFER TO SPECIFICATIONS. PULLS - (US26D) BRUSHED CHROME (UNLESS NOTED OTHERWISE ON FINISH SCHEDULE), 4" MOUNTED 1-3/4" IN FROM EDGE OF DOOR TOP AND SIDE. 1-3/4" FROM TOP OF DRAWER FACE, CENTERED. +,1*(6q23(1,1* &21&($/('6(/)&/26,1*  SHELF SUPPORTS - 32 MM LINE BORE SYSTEM WITH HAFELE #282.04.739 (METAL CLIPS); LOCKS + CATCHES - KENSTAN CAM LOCK (KEY REMOVABLE IN UNLOCKED POSITION) WITH 2" MIN. ELBOW CATCH AT DOUBLE DOORS TO MATCH PULLS, ALIGNED WITH CENTER OF PULL; TOUCH LATCH - EPCO #507 BLACK PLASTIC; DRAWER SLIDES - BLUM STANDARD DRAWER SLIDE. FULL EXTENSION, WHITE. 13.SHELVES TO HAVE 3/4" CORE (TYPICAL TO 36"; >36" = 1" CORE). SHELVES TO BE FULL DEPTH OF CABINET. 10.STENCIL PRODUCT NAME AND COLOR NAME & NUMBER AT UNDERSIDE OF ALL COUNTERTOPS, INCLUDE DATE OF FABRICATION. 14 HARDWOOD NOSING OR HARDWOOD TRIM TO BE FINISHED WITH FOUR (4) COATS OF POLYURETHANE. POLYURETHANE SHALL BE RUBBED WITH "PLASTIC WOOL" BETWEEN COATS TO OBTAIN A SMOOTH SURFACE ON THE LAST COAT. 7.ALL EXPOSED SURFACES OF CASEWORK TO RECEIVE PLASTIC LAMINATE. ADJUSTABLE SHELVES HARDWARE: KV 82/182 SHELVING SYSTEM WITH HEAVY DUTY BRACKETS AND STANDARDS (ARCHITECT TO SELECT COLOR). 15. COUNTER SUPPORT BRACKET: FAST CAP/SPEED BRACE SUPPORT BRACKET W/1/4" x 2" PHILIPS PAN HEAD SHEET METAL SCREWS OR HEAVY DUTY TOGGLE BOLTS. CONTRACTOR TO DETERMINE MAX. UNSUPPORTED SPANS AND OVERHANG WITH BRACKET MANUFACTURER (BLACK POWDER COAT FINISH UNLESS OTHERWISE SPECIFIED BY ARCHITECT). 16. 17.ALL DRAWERS SHALL HAVE FULL HEIGHT SIDES AND BACK, UNLESS NOTED OTHERWISE. 18.CONTRACTOR TO PROVIDE RUBBER DOOR SILENCERS AT ALL DOOR AND DRAWERS. 19.GROMMETS (2-3/4" INTERIOR DIAMETER TYPICAL UNLESS NOTED OTHERWISE); COLOR TBD. COORDINATE WITH COUNTER FINISH. QUANTITY T.B.D. (GROMMETS TO BE LOCATED IN FIELD BY OWNER). 20.KEYBOARD TRAYS TO BE O.F.C.I. 21.PROVIDE SEAMING PLAN FOR ALL COUNTERS. 22.ALL SOLID SURFACE COUNTERTOP SHALL HAVE 1/4" RADIUS NOSING - SEE DETAIL 1/A501. FINISHED FLOOR3'-0"2'-1"4"4"1" TYP CABINET BASE- RECYCLING SCALE: 1" = 1'-0" 8 A201 112"4" BACKSPLASH PAPER SLOT- MIN. SIZE AS REQUIRED TO FIT PAPER & RECYCLABLES BASE PER SCHEDULE CENTER DIVIDER PANEL (BETWEEN TRASH AND RECYCLING CANS) RECYCLING CAN SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER - SEE ROOM FINISH SCHEDULE AND DETAIL 1/A501 NOTE: COUNTER SHALL BE SOLID SURFACE WHEN OCCURRING AT SINK LOCATION 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE SCRIBE AND CAULK CONTINUOUS BY GENERAL CONTRACTOR B/O SOFFIT EL. = 7'-0" 1'-2"2'-0" OR 2'-6"SEE INTERIOR ELEVATIONSS.S. DOOR PULLS 4" LIGHT VALANCE - SEE ELECTRICAL DWGS FOR LIGHT FIXTURE SCRIBE AND CAULK CONTIN. BY GENERAL CONTRACTOR FINISHED END PANEL WHERE APPLICABLE PLASTIC LAMINATE ON ALL EXPOSED SURFACES ADJUSTABLE SHELF (MELAMINE) LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES W/METAL PINS TO RECEIVE HORIZONTAL SHELF P. LAM. SOFFIT ABOVE CABINETRY AS SPECIFIED ON INTERIOR ELEVATIONS. FIRE TREATED WOOD FRAMING AS REQUIRED6"TYP.FINISHED CEILING EL. = SEE R.C.P. UPPER CABINET W/ LIGHT VALANCE SCALE: 1" = 1'-0" 2 A201 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE B/O SOFFIT EL. = 7'-0"2'-0" OR 2'-6"SEE INTERIOR ELEVATIONSS.S. DOOR PULLS SCRIBE AND CAULK CONTIN. BY GENERAL CONTRACTOR PLASTIC LAMINATE ON ALL EXPOSED SURFACES ADJUSTABLE SHELF (MELAMINE) LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES W/METAL PINS TO RECEIVE HORIZONTAL SHELF FINISHED CEILING EL. = SEE R.C.P. UPPER CABINET SCALE: 1" = 1'-0" 3 A201 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE FINISHED FLOOR3'-0"112"6"2'-1" 4" BACKSPLASH 4"312" BASE - SEE ROOM FINISH SCHEDULE 1"4"END SPLASH AT WALL EQ.EQ. ￿ ȭ SINK CABINET BASE SCALE: 1" = 1'-0" 7 A201 SINK SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER - SEE DETAIL 1/A501, ROOM FINISH SCHEDULE, AND MILLWORK NOTE #22 3/4" PARTICLE BOARD, PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE SCRIBE AND CAULK CONTINUOUS BY GENERAL CONTRACTOR DOOR/ DRAWER PULL- SEE MILLWORK NOTES NOTE: COUNTER SHALL BE SOLID SURFACE WHEN OCCURRING AT SINK LOCATION CABINET BASE SCALE: 1" = 1'-0" 6 A201 4" BACKSPLASH SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER - SEE DETAIL 1/A501, ROOM FINISH SCHEDULE, & MILLWORK NOTE #22 SCRIBE AND CAULK CONTINUOUS BY GENERAL CONTRACTOR FINISHED FLOOR BRUSHED CHROME DOOR / DRAWER PULL ADJUSTABLE SHELF BASE PER ROOM FINISH SCHEDULE NOTE: COUNTER SHALL BE SOLID SURFACE WHEN OCCURRING AT SINK LOCATION LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES TO RECEIVE HORIZONTAL SHELF 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE 3'-0" SEE ELEVATION112"6"2'-1" SEE PLAN 4"1" TYP.4"312" FINISHED FLOOR3'-0"112"(2) ADJUSTABLE SHELVES (MELAMINE)4"312" SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER (SEE DETAIL 1/A501) - SEE ROOM FINISH SCHEDULE AND MILLWORK NOTE #22 BASE - SEE ROOM FINISH SCHEDULE 1" 1'-6" LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES W/METAL PINS TO RECEIVE HORIZONTAL SHELF S.S. RECESSED PULL - SEE MILLWORK NOTES CAM LOCK AT EACH CABINET DOOR PAIR (TYP.) - SEE MILLWORK NOTES5'-0"ȭ FLAT SCREEN TV (O.F.C.I.) & ASSOCIATED TV WALL BRACKET WITH ADJUSTABLE ARM (C.F.C.I.) 1" ELEC./CATV WALL OUTLETS - SEE ELECTRICAL DRAWINGS LOCATE ALL ELEC./CATV WALL OUTLETS BEHIND SCREEN - SEE ELECTRICAL DRAWINGS PLASTIC GROMMETS 3" DIA. (TYP.) DISPLAY CABINET SCALE: 1" = 1'-0" 16 A201 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE FULL-HEIGHT STORAGE CABINET SCALE: 1" = 1'-0" 9 A201 FINISHED FLOOR4"31 2"7'-0"S.S. DOOR PULLS ADJUSTABLE SHELVES; PLASTIC LAMINATE ON ALL EXPOSED SURFACES BASE PER SCHEDULE PLASTIC LAMINATE ON PLYWOOD DOOR - 4 HINGES EACH LEAF LINE BORE SYSTEM @ 1-1/4" O.C. BOTH SIDES W/METAL PINS TO RECEIVE HORIZONTAL SHELVES CAMLOCK AT EACH CABINET DOOR PAIR IF SHOWN ON INTERIOR ELEVATIONS - SEE MILLWORK NOTES 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE DOOR/ DRAWER PULL- SEE MILLWORK NOTES FINISHED FLOOR REFRIGERATOR (N.I.C.)3'-0"112"2'-1" 4" BACKSPLASH SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER - SEE ROOM FINISH SCHEDULE AND MILLWORK NOTE #224"1" TYP. BASE - SEE ROOM FINISH SCHEDULE NOTE: COUNTER SHALL BE SOLID SURFACE WHEN OCCURRING AT SINK LOCATION CABINET BASE - U.C. REFRIGERATOR SCALE: 1" = 1'-0" 12 A201 FINISHED END PANEL BEYOND; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE SCRIBE AND CAULK CONTINUOUS BY GENERAL CONTRACTOR FINISHED FLOOR3'-0"112"4" BACKSPLASH S.S. DRAWER PULL 4"312" BASE - SEE ROOM FINISH SCHEDULE4"EQ.EQ1" TYP. FILE DRAWER FILE DRAWER (FULL HEIGHT) (FULL HEIGHT) END SPLASH AT WALL PROVIDE HANGING FILE INSERT AT ALL FILE CABINET DRAWERS (TYP.) NOTE: COUNTER SHALL BE SOLID SURFACE WHEN OCCURRING AT SINK LOCATION CABINET BASE SCALE: 1" = 1'-0" 17 A201 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES - SEE ROOM FINISH SCHEDULE SCRIBE AND CAULK CONTINUOUS BY GENERAL CONTRACTOR SOLID SURFACE COUNTERTOP; MARINE GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER (SEE DETAIL 5/A501) - SEE ROOM FINISH SCHEDULE AND MILLWORK NOTE #22 1'-6" CLEAR CAULK (CONTINUOUS) ALTERNATE NO 1: UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. ALTERNATE NO. 1: SEE DETAIL 16/A501 FOR DESCRIPTION ALTERNATE 2: SEE DETAIL 9/A501 FOR ALTERNATE DESCRIPTION ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION. ALTERNATE NO. 2: SEE DETAIL 9/A501 FOR DESCRIPTION P. LAM. SOFFIT ABOVE CABINETRY AS SPECIFIED ON INTERIOR ELEVATIONS. FIRE TREATED WOOD FRAMING AS REQUIRED 1'-0"6"TYP.EXISTING CLEAN OUT AT WALL TO REMAIN 1'-2"6"TYP.METAL STUD BRACING @4'-0" O.C. TO UNDERSIDE OF STRUCTURE ABOVE (TYP.) 5/8" GYPSUM BOARD TYPE "X" ON 3-5/8" METAL STUDS @16" O.C. (TYP.) METAL CORNER BEAD (TYP.) SOFFIT EL. = SEE R.C.P. CEILING EL. = SEE R.C.P. "J" BEAD TO FINISH ROUGH DRYWALL ENDS (TYP.) GYPSUM SOFFIT DETAIL SCALE: 1-1/2" = 1'-0" 18 A102 6"TYP.RECESSED DOWN LIGHT FIXTURE- SEE ELECTRICAL DRAWINGS714"734"714" SEE R.C.P.SEE R.C.P. 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES (SEE ROOM FINISH SCHEDULE) ON 6" METAL STUDS @16" O.C. (TYP.) 3/4" PARTICLE BOARD; PLASTIC LAMINATE ON ALL EXPOSED SURFACES (SEE ROOM FINISH SCHEDULE) ON 3-5/8" METAL STUDS @16" O.C. (TYP.) EXISTING CONST. EL. = EXISTING CEILING EL. = SEE R.C.P. SOFFIT EL. = SEE R.C.P. SOFFIT DETAIL SCALE: 1-1/2" = 1'-0" 19 A102 1/2" SOLID SURFACE COUNTERTOP WITH 1/4" RADIUS EASED EDGE - SEE ROOM FINISH SCHEDULE 1/2" SOLID SURFACE COUNTERTOP (3 LAYERS GLUED TOGETHER) NOSING DETAIL- SOLID SURFACE SCALE: 6"=1'-0" 1 A501 1"112"MARINE-GRADE PLYWOOD SUBSTRATE AT ENTIRE UNDERSIDE OF COUNTER - SEE ROOM FINISH SCHEDULE DETAILS A501 BW SEAL: MARK DATE ISSUE - 05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/5/2017 8:55 AM DOOR SCHEDULE MARK LBLMATL DOOR SIZEELEV HDWR DOOR FRAME LBLMATLTRANSITIONJAMB DETAILLFSGLAZHEAD REMARKS 101 -ALUM.3'-0"x 7'-0"x 1-3/4"C 1/4" T -1 11/A601 1 HARDWARE SCHEDULE DOOR NOTES ABBREVIATIONS DOORDR HOLLOW METALHM INSULATED HOLLOW METALIHM KICKPLATE (HEIGHT")K(12) MTL.METAL MIN MINERAL CORE PTD.PAINTED SCW SOLID CORE WOOD S.S.STAINLESS STEEL STL.STEEL TI TEMPERED INSULATED V.I.F.VERIFY IN FIELD WD.WOOD ALUMINUMALUM T TEMPERED 1/4" WG 1/4" WIRE GLASS 1/4" T 1/4" TEMPERED GLASS 1" IG 1" INSULATED GLASS ANODIZED ALUMINUMAA (SEE DOOR NOTES)1. ALL DOOR HANDLES SHALL BE OF LEVER TYPE MEETING CURRENT ADA STANDARDS, (AS NOTED IN THE HARDWARE SCHEDULE). DOOR HANDLES TO ROOMS CONSTITUTING A HAZARD (ELECTRICAL ROOMS, MECHANICAL ROOMS, SOILED UTILITY ROOMS, ETC.) SHALL BE LEVER TYPE WITH A KNURLED FINISH ON THE GRIP SURFACE. 2. ALL DOOR LEVERS SHALL REMAIN NON-RIGID AT LOCKED CONDITION, EXCEPT AS NOTED. 3. ALL LOCKSETS & LATCHSETS SHALL BE OF MORTISE DESIGN. 4. ALL HARDWARE FINISH SHALL BE BRUSHED STAINLESS STL. (US32D) 5. ALL PRODUCTS SPECIFIED ON AN 'OR EQUAL' BASIS UNLESS OTHERWISE NOTED. 6. PROVIDE REQUIRED POWER SUPPLY SYSTEMS FOR OPERATING ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, ELECTRIC STRIKES, & MARLOK ELECTRONIC CYLINDER SYSTEMS. COORD. REQUIREMENTS W/E.C. 7. ALL ELECTROMAGNETIC LOCKS, ELECTROMECHANICAL LOCKS, & ELECTRIC STRIKES SHALL BE OF THE 'FAIL SAFE' DESIGN, UNLOCKING WHEN THE FIRE ALARM IS ACTIVATED OR ELECTRICAL POWER IS INTERRUPTED. 8. ALL STAINLESS STEEL KICKPLATES SHALL BE 2" LESS THAN DOOR WIDTH x 12" HIGH (TYPICAL - U.O.N.) AND SHALL BE MOUNTED 1" FROM THE BOTTOM OF THE DOOR; SEE SPECIFICATION. 9. ALL HOLLOW METAL FRAMES SHALL BE SHOP WELDED UNLESS NOTED OTHERWISE. 10. SPECIES OF ALL DOORS SHALL BE MAPLE; SEE SPECIFICATION FOR ADDITIONAL INFORMATION. KAWNEER 350 MEDIUM STILE DOOR WINDOW SCHEDULE MARKR. O. SIZE ELEVDETAIL HEAD REMARKSTYPEJAMBSILL SLIDING WINDOW SYSTEM- MAPLE TRIM FIXED WINDOW- H.M. TRIM W1 W2 4'-0"W x 4'-2"H 2'-0"W x 4'-2"H 14/A601 15/A601 14/A601 17/A601 15/A601 SIM. 1/4" TEMPERED GLASS 1/4" TEMPERED GLASS 3.1-1/2 PAIR BUTT HINGES, BALL BEARING 1 - PASSAGE LATCHSET WITH LEVER HANDLES 1 - DOOR STOP, WALL OR FLOOR MOUNT 1 - SET DOOR MUTES 10.1-1/2 PAIR BUTT HINGES, BALL BEARING 1 - PASSAGE LATCHSET WITH PUSH BAR INTERIOR, NO TRIM EXTERIOR 1 - DOOR CLOSER 1 - SET DOOR MUTES 11.1-1/2 PAIR BUTT HINGES, BALL BEARING 1 - ENTRANCE LOCKSET WITH PUSH BAR INTERIOR 1 - DOOR CLOSER 1 - SET DOOR MUTES 1.1-1/2 PAIR BUTT HINGES, BALL BEARING 1 - OFFICE LOCKSET WITH LEVER HANDLES 1 - DOOR STOP, WALL OR FLOOR MOUNT 1 - SET DOOR MUTES 103 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 1 - 104 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 1 - 106 -ALUM./GL3'-0"x 7'-0"x 1-3/4"D 1" IG -1 ALUM.11 EXTERIOR DR @ LOCATION OF EXISTING WINDOW (MODIFY AS REQD). MATCH EXISTING EXTERIOR DOORS. 109 -GL/ALUM.3'-0"x 8'-0"x 1-3/4"W3 1/2" T -1 -3 FRAMELESS GLASS (BASE BID; SEE ALTERNATES) 110 -SCW3'-0"x 7'-0"x 1-3/4"A --1 HM 6 - ALUM. / GLASS STOREFRONT SYSTEM W3 12'-0"W x 7'-0"H 18/A601 19/A601 1/4" TEMPERED GLASS W4 RELOCATED EXTERIOR WINDOW 11/A601 11/A601 11/A601 11/A601 11/A601 11/A601 11/A601 16B/A601 16A / A601 16A / A601 16A / A601 18 / A602 12 / A601ETRETR 3 - PAIR BUTT HINGES, BALL BEARING 2 - SERVICE LATCHSET WITH LEVER HANDLES 2 - DOOR STOPS 2 - SET DOOR MUTES 6. 15/A601 18/A601 ETR ETR (FIXED EXTERIOR WINDOW) 8/A602 ALUM. WINDOW ELEVATIONS DOOR ELEVATIONS B SEE SCHED.2"TYP.2" TYP. 5"x20" GLASS VISION PANEL IN PAINTED H.M. FRAME SEE SCHED. SEE SCHED. SEE SCHED. A C10"6" TYP.312" TYP. 2" TYP.SEE SCHED.2" TYP.2"TYP.2"TYP.SEE SCHED.2" TYP. 2" TYP. 1/4" TEMPERED GLASS IN CLEAR ANOD. ALUM. FRAME2" TYP.2'-10"4'-0" W14'-2"W24'-2"2'-10"W3 109 SEE SCHED. D SEE SCHED.2" TYP.2"TYP.2" TYP.2"TYP.2'-0" 11'-10" INSULATED GLASS @ EXTERIOR DOOR 7'-10"312" TYP.10"312" TYP.312" TYP.10"W3 109 11'-10"7'-10"BASE BID ALTERNATE NO. 4 ALTERNATE NO. 4: UNDER ALTERNATE NO. 4, DELETE THE GLASS WINDOW WALL AT CONFERENCE ROOM #109, AND PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM AND GLASS STOREFRONT SYSTEM (KAWNEER TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR, OR EQUAL); SEE SHEET A601 AND SHEET A602. FULL LIGHT MONOLITHIC GLASS DOOR, TEMPERED, W/C.R. LAURENCE PATCH FITTINGS 2 A602 6 A602 9 A602 1 A602 3 A602 4 A602 7 A602 8 A602 18 A601 18 A601 19 A601 20 A601 SEE FLOOR PLAN FOR WALL TYPE SHIM AS REQUIRED CAULK AROUND PERIMETER (BOTH SIDES) HOLLOW METAL FRAME (PAINT) 1/4" TEMPERED SAFETY GLASS TOP HUNG SLIDING WINDOW SYSTEM SLIDING WINDOW HEAD DETAIL SCALE: 1-1/2" = 1'-0" 14 A601 WAITING AREA RECEPTION AREA NOTE: PROVIDE NYLON GUIDES, SLIDING GLASS, DOOR LOCK WITH KEY, AND STICK ON FINGER PULL WAITING AREA RECEPTION AREA SEE FLOOR PLAN FOR WALL TYPE WOOD BLOCKING AS REQUIRED 1/4" TEMPERED GLASS TOP HUNG SLIDING WINDOW SYSTEM SLIDING WINDOW SILL DETAIL SCALE: 1-1/2" = 1'-0" 17 A601 HOLLOW METAL FRAME (PAINT PER FINISH SCHEDULE) NYLON GUIDES NOTE: PROVIDE NYLON GUIDES, SLIDING GLASS, DOOR LOCK WITH KEY, AND STICK ON FINGER PULL HOLLOW METAL FRAME - PAINT; SEE SPEC. (TYP.) CAULK CONT. (BOTH SIDES) 2x WOOD BLOCKING (FIRE -RETARDANT) SEE FLOOR PLAN FOR WALL TYPE 12" TYP.2"12"WALL ANCHORS & BASE CLIPS DOOR - SEE DOOR SCHEDULE DOOR HEAD / JAMB DETAIL SCALE: 3" = 1'-0" 11 A601 FIXED WINDOW HEAD / JAMB DETAIL SCALE: 3" = 1'-0" 15 A601 2"12" TYP. HOLLOW METAL FRAME - SEE SPEC. PAINT (TYP.) 2x WOOD BLOCKING (FIRE TREATED) SEE FLOOR PLAN FOR WALL TYPE CAULK CONT. (BOTH SIDES) 1/4" SAFETY GLASS RUBBER GASKET (TYP.) GLASS STOP FOUNDATION WALL SWEEP & CONT. WEATHERSTRIPPING (TYP.) THERMALLY - BROKEN ANODIZED ALUMINUM THRESHOLD INSULATED ALUM./ GLASS DOOR; SEE DOOR SCHEDULE CAULK CONT. - BOTH SIDES (TYP.) OUTSIDE INSIDE 12"MAX.COMPRESSIBLE FILLER AND CAULK EXTERIOR DOOR SILL DETAIL SCALE: 3" = 1'-0" 12 A601 T.O. LANDING EL. = 2" CAULK AND BACKER ROD AROUND PERIMETER BOTH SIDES (TYP.) CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM 2" 1/4" TEMPERED SAFETY GLASS 2x WOOD BLOCKING (FIRE - RETARDANT) SEE FLOOR PLAN FOR WALL TYPE 412"1/4" TEMPERED SAFETY GLASS 2"1/4" TEMPERED SAFETY GLASS SHIM AS REQUIRED CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM CAULK AND BACKER ROD AROUND PERIMETER BOTH SIDES (TYP.) SHIM AS REQ'D CLEAR ANODIZED ALUMINUM STOREFRONT SYSTEM 412"41 2" 41 2" SHIM AS REQUIRED (TYP.) STOREFRONT SYSTEM STOREFRONT SYSTEM STOREFRONT SYSTEM WINDOW HEAD/JAMB DETAIL SCALE: 3" = 1'-0" 18 A601 WINDOW SILL DETAIL SCALE: 3" = 1'-0" 19 A601 WINDOW MULLION DETAIL SCALE: 3" = 1'-0" 20 A601 CARPET - SEE ROOM FINISH SCHEDULE 1/2"MAXIMUMUNDERCUTFLOORING TRANSITION CENTERED ON DOOR, NO TRANSITION STRIP - CONTRACTOR SHALL PROVIDE A STRAIGHT EVEN CUT AT TRANSITION FROM CARPET TO RESILIENT FLOORING CL DOOR (SHOWN IN CLOSED POSITION) - SEE DOOR SCHEDULE; SEE SPEC. (TYP.) RESILIENT FLOORING - SEE ROOM FINISH SCHEDULE DOOR TRANSITION DETAIL SCALE: 6" = 1'-0" 16B A601 CARPET - SEE ROOM FINISH SCHEDULE1/2"MAXIMUMUNDERCUTCARPET - SEE ROOM FINISH SCHEDULE CL DOOR (SHOWN IN CLOSED POSITION) - SEE DOOR SCHEDULE; SEE SPEC. (TYP.) DOOR TRANSITION DETAIL SCALE: 6" = 1'-0" 16A A601 DOOR & WINDOW SCHEDULES AND DETAILS A601 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 5:01 PM 3/8" [9]11/16" [17] 1" [26]1 3/16" [30]DAYLITE OPENING EU0FRAMED6MSA EU0FP6MBL EU0CLIPD6MSA EU0RG6MBL FRAME DIMENSION 1/2" [12] THICK GLASS 9/16" [14] 1 3/16" [30]11/16" [17] 1 7/8" [47]DAYLITE OPENING EU0FRAMED6MSA EU0FP6MBL EU0CLIPD6MSA EU0RG6MBL 1/2" [12] THICK GLASS DAYLITE OPENING EU0BASISD6MSA EU0DJ6MBL DOOR OPENING5/8" [16] DOOR FRAME 9/16" [14] 1/4" [6] 1 3/16" [30]DAYLITE OPENING DOOR OPENING 5/8" [16] DOOR FRAME 9/16" [14] 3/16" [5] FRAME DIMENSION 9/16" [14] DAYLITE OPENING DAYLITE OPENING 1/8" [3] 1/2" [12] THICK GLASS1 3/16" [30]1 3/16" [30]1 7/8" [48]EU0BASISD6MSA EU0DJ6MBL 1 7/8" [48]1/2" [12] THICK GLASS 1/2" [12] THICK GLASS NET DOOR SIZE NET DOOR SIZE EU0LKSSA EU0LHSA EU0HSSA SIDELITE HEAD DETAIL SCALE: 6" = 1'-0" 1 A601 SIDELITE SILL DETAIL SCALE: 6" = 1'-0" 2 A601 SWING IN DOOR HEAD DETAIL SCALE: 6" = 1'-0" 3 A601 SWING IN DOOR SILL DETAIL SCALE: 6" = 1'-0" 4 A601 SIDELITE JAMB DETAIL SCALE: 6" = 1'-0" 6 A601 SIDELITE GLASS JOINT DETAIL SCALE: 6" = 1'-0" 7 A601 SIDELITE/ SWING IN DOOR JAMB DETAIL SCALE: 6" = 1'-0" 8 A601 SWING IN DOOR JAMB DETAIL SCALE: 6" = 1'-0" 9 A601 MANUFACTURER'S ACOUSTICAL SEAL BETWEEN ALL MONOLITHIC GLASS PANELS (TYPICAL) ACOUSTICAL GLASS WALL & DOOR DETAILS (BASE BID) A602 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 5:02 PM PAINTPAINTSTAIN & VARNISHCARPETRESILIENT FLOORINGFLOOR TILERESILIENT BASEPAINTFLOOR BASE WALLS DOOR REMARKS WESTSOUTH PAINTEASTNORTH PAINTROOM NAMEROOM# ROOM FINISH SCHEDULE ENTRANCE VESTIBULE B1 P2 P2 P2 P2 S P1 B1 S P1P2P2P2 C1101 102 103 104 105 106 107 108 109 110 WAITING ROOM ADMIN OFFICE P2 P2 P2 P2 P2P2 P2 P2 P2 P2 P2 P2P2 P2 P2 P2 P2 P2 P2 P2P2 P2 P3 P2 P2 P2 P2 P2P2 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 ATTORNEY OFFICE COPY AREA HALL STAFF BREAK ROOM TOILET ROOM CONFERENCE ROOM FILES / STORAGE ROOM TRIM ABBREVIATIONS GENERAL FINISH NOTES A.IN ALL AREAS WHERE DEMOLITION OCCURS, PATCH TO MATCH EXISTING/ NEW FINISHES AS SCHEDULED. B.SEE REFLECTED CEILING PLAN FOR CEILING TYPES AND FINISHES. CG CORNER GUARD CPT.CARPET E.T.R.EXISTING TO REMAIN LVT LUXURY VINYL TILE M.E.MATCH EXISTING MOD.MODIFY EXISTING AS REQUIRED MTL.METAL PTD.PAINTED P.T.M.PATCH TO MATCH EXISTING T.B.D.TO BE DETERMINED U.N.O. UNLESS NOTED OTHERWISE V.I.F.VERIFY IN FIELD WD. WOOD FINISHES BY BLDG OWNER C2 C2 C2 C2 C2 V1 T1 C2 PAINT AND WALL, DOOR, & TRIM FINISHES P1 - PAINT 1 (TRIM): MANUFACTURER: BENJAMIN MOORE FINISH: ADVANCE, SEMI-GLOSS COLOR: SIMPLY WHITE #2143-70 P2 - PAINT 2 (TYPICAL WALLS): MANUFACTURER: SHERWIN WILLIAMS FINISH: EGGSHELL COLOR: SOFTER TAN #SW-6141 P3 - PAINT 3 (ACCENT): MANUFACTURER: BENJAMIN MOORE FINISH: EGGSHELL COLOR: SCHOONER #AF-420 1.ALL NEW WOOD VENEER DOORS SHALL BE MAPLE VENEER U.N.O. FINISH SHALL BE 2 COATS OF CLEAR, SATIN FINISH POLYURETHANE. SEE DOOR SCHEDULE. 2.PAINT ALL PAINTED TRIM IN PROJECT AREA P1. 3.UNDERSIDES AND ALL EXPOSED FACES OF ALL GYPSUM SOFFITS (SEE R.C.P.) SHALL BE PAINTED P2 U.N.O. 4.ALL GYPSUM BOARD CEILINGS (SEE R.C.P.) SHALL BE PAINTED BENJAMIN MOORE, CEILING WHITE U.N.O. MILLWORK AND SURFACING PL1 - PLASTIC LAMINATE 1 (VERTICAL/ CABINETRY): MANUFACTURER: WILSONART COLOR: FONTHILL PEAR #10745-60 FINISH: MATTE SS1 - SOLID SURFACE 1: MANUFACTURER: CORIAN COLOR: SORREL 1.ALL COUNTERTOPS WITH SINKS SHALL BE SOLID SURFACE SS1. SINKS SHALL BE STAINLESS STEEL UNDERMOUNTS; SEE PLUMBING DRAWINGS. 2.SEE MILLWORK NOTES, SHEET A501, FOR CABINETRY HARDWARE INFORMATION. 3.SOLID SURFACE WALL CAPS AT HALF WALLS SHALL BE SS1. SEE WALL TYPE 2/A101. 4.COLOR OF METAL SUPPORT BRACKETS AT MILLWORK COUNTERTOPS SHALL BE BLACK. SEE MILLWORK NOTES. FLOORING, BASE, AND TILE FLOORING: C1 - WALK-OFF CARPET: MANUFACTURER: SHAW STYLE/ SERIES: PORTAL #5T035 SIZE: 24" x 24" COLOR: EBONY #34500 INSTALLATION METHOD: MONOLITHIC C2 - CARPET TILE: MANUFACTURER: J+J INVISION STYLE/ SERIES: INCEPTION NEUTRAL PLANK #7019 SIZE: 18" X 36" COLOR: GENERATE #1742 INSTALLATION METHOD: ASHLAR V1 - VINYL TILE MANUFACTURER: BOLYU STYLE/ SERIES: MINERAL SIZE: 18" X 36" COLOR: URBAN GREY #BLVEL-002 INSTALLATION METHOD: MONOLITHIC _______________________________________________ TRANSITIONS: TS1 - TRANSITION STRIP: MANUFACTURER: JOHNSONITE COLOR: MOONROCK #29 _______________________________________________ WALL BASE: B1 - VINYL BASE: MANUFACTURER: JOHNSONITE HEIGHT: 4" STYLE/ SERIES: TRADITIONAL WALL BASE x CARPET AREAS- STRAIGHT/ xRESILIENT FLOORING AREAS- COVE COLOR: BLACK #40 _______________________________________________ TILE: T1 - PORCELAIN TILE: BY BUILDING OWNER 1.CENTER ALL FLOOR TILES IN ROOM WHERE FEASIBLE. 2.INSTALL TRANSITION STRIPS WHERE REQUIRED UNDER DOORS DIRECTLY UNDER THE CLOSED DOOR. SEE DETAILS ON DOOR SCHEDULE. 3.PROVIDE TRANSITION STRIPS WHERE REQUIRED WHERE NEW FLOORING ABUTS EXISTING FLOORING SURFACES TO REMAIN. 6. PROVIDE TRANSITION STRIPS WHERE REQUIRED BY DIFFERENT FINISHED FLOOR HEIGHTS/ THICKNESS. 7.ALL RESILIENT BASE SHALL BE ROLLED GOODS. USE LONGEST LENGTHS POSSIBLE AND MINIMIZE SEAMS. 8.RESILIENT BASE: USE STRAIGHT BASE FOR CARPET CONDITION; COVE BASE FOR RESILIENT FLOORING CONDITION. WALL PROTECTION CHAIR RAILS: SEE DETAIL 17/AF601 MANUFACTURER: JOHNSONITE STYLE / SERIES: MILLWORK CONTOURED CHAIR RAIL COLOR: BLACK #40 CORNER GUARDS: SEE DETAIL 16/AF601 MANUFACTURER: INPRO CORPORATION STYLE / SERIES&/($5q FRP PANEL: SEE DETAIL 18/AF601 MANUFACTUER: MARLITE STYLE / SERIES: STANDARD FRP, PEBBLED COLOR: MATCH WALL COLOR 1.TERMINATE CHAIR RAILS TO PROVIDE 6" MINIMUM CLEARANCE BETWEEN RAIL AND ANY OPENINGS OR CORNERS. 2.INSTALL CORNER GUARDS WHERE SHOWN ON FINISHES FLOOR PLAN, AND AT ANY OTHER HIGH-TRAFFIC/ HIGH-IMPACT CORNERS AS REQUIRED. 3.INSTALL FRP PANEL AT SERVICE SINK; MATCH WIDTH OF MANUFACTURER'S OPTIONAL WALL GUARD x HEIGHT TO COVER FAUCET AND OTHER ACCESSORIES PLUS 4"; PROVIDE AND INSTALL 7/16" EDGE MOULDING (TYPICAL) MATERIALS NOTES MATERIALS NOTESMATERIALSNOTES MATERIALS NOTES CHAIR RAIL P3 P2 V1 P3 P3B1 B1 B1 B1 B1 B1 B1 B1 SEE NOTE 3. WAITING 102 218 SF N OFFICE N FRIDGE CONFERENCE ROOM 109 214 SF FILES/ STORAGE 110 115 SF ATTORNEY OFFICE 104 153 SF ADMIN OFFICE 103 103 SF ENTRANCE VESTIBULE 101 42 SF COAT RACK COPY AREA 105 82 SF HALL 106 83 SF STAFF BREAK 107 53 SF TOILET 108 51 SF ALTERNATE NO. 1: UNDER ALTERNATE NO. 1, DELETE NEW CASEWORK IN CONFERENCE ROOM #109 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND THE NEW SUSPENDED ACOUSTICAL CEILING TO PARTITION. ALTERNATE NO. 4: UNDER ALTERNATE NO. 4, DELETE THE GLASS WINDOW WALL AT CONFERENCE ROOM #109, AND PROVIDE AND INSTALL, IN ITS PLACE, AN ALUMINUM AND GLASS STOREFRONT SYSTEM (KAWNEER TRI-FAB 450 WITH A KAWNEER 190 ENTRANCE DOOR, OR EQUAL); SEE SHEET A601 AND SHEET A602. FINISHES FLOOR PLAN SCALE: 1/4" = 1'-0" NEW WINDOW SHADES AT ALL EXTERIOR WINDOWS- SEE SPEC. CG 16 AF601 CGCG NEW CHAIR RAIL- SEE FINISH SCHEDULEC1C2 C2V1C2T1 C2V1 F.R.P. PANEL BEHIND MOP SINK- SEE DETAIL 18/AF601 INPRO CORP CLEAR CORNER GUARD (USE ONLY FOR LOW IMPACT AREAS/ OCCUPANCIES) CORNER GUARD DETAIL- IPC CLEAR SCALE: 6" = 1'-0" 16 AF601 CLEAR CORNER GUARD .050" [.127mm] THICK 34"SELF-TAPPING NAILSCREWS CLEAR CORNER GUARD .100" [2.54mm] THICK PAN HEAD SELF-TAPPING NAILSCREWS 212"118"PAN HEAD SELF-TAPPING NAILSCREWS CLEAR CORNER GUARD .075" [1.90mm] THICK q%8//126(q q q q$1'q352),/(6$9$,/$%/( IN 2 1/2" WING SIZE ONLY) CHAIR RAIL DETAIL SCALE: 6" = 1'-0" 17 AF601 CL SEE FLOOR PLAN FOR WALL TYPE V.I.F.JOHNSONITE MILLWORK CONTOURED CHAIR RAIL - SEE FINISH SCHEDULE. INSTALL PER MANUFACTURER'S SPECIFICATIONS. COORDINATE MOUNTING HEIGHT WITH OWNER AFTER FURNITURE SELECTION. ￿ TOP EDGE - M370 1 FRP - PVC TRIMMARLITE PANEL SUBWALL M370 EDGE TRIM CEILING LINE OR TOP OF ELEVATION SEALANT 332"716"14" BOTTOM EDGE - M370 2 FRP - PVC TRIMMARLITE ADHESIVE PANEL SUBWALL M370 EDGE TRIM SEALANT FLOOR LINE14"716"332" VERTICAL EDGE - M370 3 FRP - PVC TRIM SUBWALL PANEL SEALANT M370 EDGE TRIM ADHESIVE 14"716"332"FRP PANEL DETAIL SCALE: N.T.S. 18 AF601 FINISH SCHEDULE AF601 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:50 PM ALL MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHOWN IS DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL SCOPE OF EACH TRADE. MECHANICAL NOTES THE GENERAL PLUMBING NOTES AND SUMMARY OF WORK, ABOVE, ARE INTENDED TO DESCRIBE THE SCOPE OF WORK TO BE EXECUTED BY THE PLUMBING CONTRACTOR. THE CONTRACT DRAWINGS DETAIL THE GENERAL SCOPE AND PERFORMANCE REQUIREMENTS OF THE CONTRACT. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL DESIGN AND INSTALLATION OF HIS / HER SCOPE IN ACCORDANCE WITH ALL APPLICABLE CODES. 1. FIXTURES AND TRIM AS NOTED SHALL BE "ACCESSIBLE" AND SHALL BE INSTALLED TO ADA/ANSI A117 REQUIREMENTS. 2. INSTALL TRUEBRO INC. MODEL #102, HANDI LAV-GUARD PROTECTOR ON THE HOT, COLD, AND DRAIN PIPING UNDER FIXTURE. 3. PROVIDE ISOLATION VALVES AT ALL FIXTURES (TYPICAL). 4. PROVIDE WATER HAMMER ARRESTORS AT FIXTURES (TYPICAL) 5. SEE FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO EACH FIXTURE. 6. FIXTURES PROVIDED BY BUILDING OWNER AND INSTALLED BY CONTRACTOR. REMARKS: SYMBOL PLUMBING FIXTURE SCHEDULE MANUFACTURER MODEL NO.DESCRIPTION ACCESSORIES REMARKS BUILDING OWNER'S STANDARD E. L. MUSTEE NOT USED BUILDING OWNER'S STANDARD ELKAY DROP-IN STAINLESS STEEL SINK BASINLR-1919 CHICAGO MODEL # 895-319ABCP, CHROME PLATED GOOSENECK FAUCET, 6" WRIST BLADE HANDLES, 0.5 GPM AERATOR, CHROME PLATED GRID DRAIN LEGEND HOT WATER PIPING COLD WATER PIPING SANITARY SEWER PIPING PLUMBING VENT ABOVE CEILING HW CW S V PLUMBING CONTRACTOR SHALL ROUTE NEW VENT TO VTR LOCATED IN COORDINATION WITH G.C. GENERAL PLUMBING NOTES A. WASTE PIPING PROVIDE SHOCK ABSORBERS AS REQUIRED; PROVIDE VALVES, UNIONS, AND COUPLINGS TO ISOLATE EQUIPMENT AND SUPPLY OR DRAIN SYSTEM. PROVIDE SHUT OFF VALVES AT EACH FIXTURE OR PIECE OF EQUIPMENT. ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES. THIS SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE COMMONWEALTH OF MASSACHUSETTS STATE PLUMBING CODE. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING PLUMBING FIXTURES AND EQUIPMENT SUPPLIES. IT IS IN THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK. PLUMBING CONTRACTOR SHALL PAY ALL FEES AND SECURE ALL PERMITS AND LICENSES APPLICABLE TO THIS SECTION OF THE WORK. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED. VERIFY LOCATION OF WATER SERVICE AND THE LOCATION/INVERTS OF SANITARY/STORM PIPING PRIOR TO INSTALLATION. COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE, ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR. ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM ACCEPTANCE BY THE OWNER. ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT. PLUMBING CONTRACTOR IS REQUIRED TO VERIFY ALL INVERTS PRIOR TO ANY PIPING INSTALLATION. INVERT NUMBERS (IF PROVIDED) WERE OBTAINED FROM PREVIOUS CONSTRUCTION DOCUMENTS AND PREVIOUS SURVEYS. THESE NUMBERS WERE NOT "AS-BUILT" NUMBERS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. TEST ALL PIPING SYSTEMS - DISINFECT HOT AND COLD WATER PIPING. SUPPORT ALL PIPING WITH CLEVIS TYPE HANGERS AS REQUIRED BY CODE; USE NO STRAPS. 1. BELOW FLOOR - CAST IRON, NO HUB OR COMPRESSION FITTING. B. VENT PIPING 1. ABOVE GRADE OR FLOOR - DWV COPPER, CAST IRON, NO HUB. OR AS APPROVED BY LOCAL PLUMBING INSPECTOR. C. WATER SUPPLY PIPING 1. ABOVE GRADE OR FLOOR - TYPE L COPPER. 2. PROVIDE 95/5 TIN-ANTIMONY SOLDER JOINTS. - CONNECT NEW SINKS TO PLUMBING SYSTEMS: HW - 1/2", CW - 1/2", S - 2", V - 2" - CONNECT NEW FLOOR SINK TO EXISTING PLUMBING SYSTEMS: HW - 1/2", CW - 1/2", S - 2", V - 2" - CONNECT NEW TOILET TO PLUMBING SYSTEMS: CW - 1/2", S - 4", V - 4" FIXTURE CONNECTION SCHEDULE LAVATORY: ACCESSIBLE, VITREOUS CHINA WALL-MOUNTED LAVATORY SIMILAR TO KOHLER MORNINGSIDE WATER CLOSET: ACCESSIBLE, VITREOUS CHINA , TANK-TYPE, FLOOR-MOUNTED WATER CLOSET 63M ONE-PIECE MOLDED, HIGH-IMPACT RESISTANT STRUCTURAL FIBERGLASS BASIN (24"x24") W/S.S. STRAINER & INTEGRALLY MOLDED DRAIN & SEAL E. L. MUSTEE MODEL # 67.24C 20 GAUGE #304 S.S. DURAGUARD WALLGUARD, 12" HIGH; OPTIONAL SEAL AS REQUIRED SUMMARY OF WORK: SEE FIXTURE CONNECTION SCHEDULE ABOVE. WAITING 102 218 SF CONFERENCE ROOM 109 214 SF FILES/ STORAGE 110 115 SF ATTORNEY OFFICE 104 153 SF ADMIN OFFICE 103 103 SF ENTRANCE VESTIBULE 101 42 SF COPY AREA 105 82 SF HALL 106 83 SF STAFF BREAK 107 53 SF TOILET 108 51 SF P P F F F PLUMBING PLAN SCALE: 1/4" = 1'-0" INSTALL SINK IN MILLWORK AT EXISTING PIPING TERMINATIONS; MODIFY PIPING AS REQUIRED FOR NEW WORK; SEE PLUMBING CONNECTION SCHEDULE INSTALL TOILET AT EXISTING PLUMBING PIPING TERMINATIONS; MODIFY PIPING AS REQUIRED FOR NEW WORK; SEE PLUMBING CONNECTION SCHEDULE CWCWCWS S S S S SHWHWCAP EXISTING SANITARY IN ACCORDANCE W/APPLICABLE CODES AND STANDARDS SSHW HW HW HW HW INSTALL FLOOR SINK AND ASSOCIATED PLUMBING PIPING; MODIFY EXISTING PIPING AS REQUIRED FOR NEW WORK; SEE PLUMBING CONNECTION SCHEDULE EXISTING CLEAN OUT AT WALL TO REMAIN; CONTRACTOR TO PROVIDE COVER AND FLANGE/TRIM. COORDINATE WITH CABINETRY AND PROVIDE ACCESS AS REQUIRED. EXISTING CLEAN OUT AT WALL TO REMAIN; CONTRACTOR TO PROVIDE COVER AND FLANGE/TRIM. COORDINATE WITH FINISHES - SEE FINISH SCHEDULE INSTALL LAVORATORY AT EXISTING PLUMBING PIPING TERMINATIONS; MODIFY PIPING AS REQUIRED FOR NEW WORK; SEE PLUMBING CONNECTION SCHEDULE PLUMBING PLAN, DETAILS & SCHEDULES P101 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:55 PM AIR CHANGES PER HOURRELATIVE PRESSURETOTAL CFMROOM AIR BALANCING SCHEDULE ROOM #ROOM NAME REMARKS TO ADJACENT SPACESRELATIVE HUMIDITYPARAMETERS ROOM VOLUME (CF)102 WAITING ROOM 108 ADMIN. OFFICE 110 107 STAFF BREAK 4SQ. FT.4 4 103 TOILET 10 FILES / STORAGE 4 NEG. 101 ENTRANCE VESTIBULE 4 ATTORNEY OFFICE 4104 COPY AREA 4105 106 HALL 4 CONFERENCE ROOM 4109 41 220 103 153 82 83 53 53 214 115 380 2035 953 1,416 759 768 491 491 1712 1064 25 136 64 95 51 52 33 82 115 71 ALL MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHOWN IS DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL SCOPE OF EACH TRADE. MECHANICAL NOTES THE GENERAL HVAC NOTES AND SUMMARY OF WORK, ABOVE, ARE INTENDED TO DESCRIBE THE SCOPE OF WORK TO BE EXECUTED BY THE MECHANICAL CONTRACTOR. THE CONTRACT DRAWINGS DETAIL THE GENERAL SCOPE AND PERFORMANCE REQUIREMENTS OF THE CONTRACT. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL DESIGN AND INSTALLATION OF HIS / HER SCOPE IN ACCORDANCE WITH ALL APPLICABLE CODES. LEGEND CEILING SUPPLY DIFFUSER CEILING RETURN OR EXHAUST GRILLE HVAC NOTES THE SYSTEM DESCRIBED HEREIN IS INTENDED TO DESCRIBE THE GENERAL INTENT OF THE MODIFICATIONS TO EXISTING SYSTEMS. THE ACTUAL METHODS OF ACHIEVING THIS DESIRED INTENT SHALL REMAIN THE RESPONSIBILITY OF THE HVAC CONTRACTOR AND THE GENERAL CONTRACTOR IN CONSULTATION WITH THE BUILDING OWNER: 1.FURNISH AND INSTALL A HEATING, VENTILATING AND AIR CONDITIONING SYSTEM AS SHOWN ON THE PLANS IN WORKING ORDER TO THE OWNER USING NEW AND/OR EXISTING EQUIPMENT AND MODIFIED EXISTING DUCTWORK AND CONTROLS. 2.ALL EQUIPMENT AND WORKMANSHIP TO BE GUARANTEED BY CONTRACTOR FOR ONE YEAR FROM DATE OF FINAL PAYMENT. 3.SUBMIT AT LEAST THREE (3) COPIES OF SHOP DRAWINGS ON ALL EQUIPMENT TO ARCHITECT / ENGINEER. 4.ALL EQUIPMENT AND INSTALLATIONS SHALL CONFORM TO STATE AND LOCAL CODES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. GALVANIZED SHEET METAL DUCTS: UP TO 12" 26 GA; 13" TO 30" 24 GA; ELBOWS AND TRANSFORMATION PIECES: 2 GAUGES HEAVIER. 5. BALANCE AIR AND WATER SIDE OF SYSTEM PER APPLICABLE CODE(S) AND STANDARDS.6. CEILING DIFFUSERS: MATCH EXISTING UNLESS OTHERWISE NOTED ON CONTRACT DRAWINGS.7. CEILING RETURN AIR GRILLES: MATCH EXISTING UNLESS OTHERWISE NOTED ON CONTRACT DRAWINGS. 8. INSULATE ALL PIPING WITH 1" ASJ FIBERGLASS WITH VAPOR BARRIER. SEAL ANDS. ZESTON PVC AT ELBOWS. 9. TEMPERATURE CONTROLS: - MODIFY EXISTING SYSTEM FOR NEW LAYOUT. - ALL CONTROL WIRING (LOW AMD LINE VOLTAGE) BY HVAC CONTRACTOR. 10. AIR BALANCING: - RE-BALANCE COMPLETED SYSTEM TO ACHIEVE AIR FLOW IN CONFORMANCE WITH APPLICABLE CODES AND STANDARDS (DEFINING CODE ASSUMED TO BE IMC 2009). 11. POS. POS. POS. POS. POS. POS. POS. POS. POS. SUMMARY OF WORK: WAITING 102 218 SF CONFERENCE ROOM 109 214 SF FILES/ STORAGE 110 115 SF ATTORNEY OFFICE 104 153 SF ADMIN OFFICE 103 103 SF ENTRANCE VESTIBULE 101 42 SF COPY AREA 105 82 SF HALL 106 83 SF STAFF BREAK 107 53 SF TOILET 108 51 SF F S F S 2 2 B B ETR ETR A (NL) B B B B B BB BBB B B B BB B B C C C C CCC C C C C C C C C A (NL)A (NL) 1 1 1 1 1 1 1 1 H H H (NL) FF SIM ETR HVAC PLAN SCALE: 1/4" = 1'-0" HVAC PLAN M101 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:54 PM LEGEND HOME RUN TO EXISTING PANEL - ELECTRICAL CONTRACTOR TO BALANCE PANEL BASED ON NEW LOADS SINGLE POLE SWITCH PHONE SYSTEM OUTLET FIRE ALARM PULL STATION FIRE ALARM HORN/STROBE FLUSH CEILING MOUNTED SPEAKERS CEILING - MOUNTED EXIT SIGN DUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATED COMPUTER OUTLET QUADRUPLEX RECEPTACLE AT 18" OR HEIGHT INDICATED COMPUTER/PHONE OUTLET 2'-0" UNDERCABINET LIGHTING FIXTURE 4'-0" UNDERCABINET LIGHTING FIXTURE ELECTRICAL NOTES LIGHT FIXTURE CEILING MOUNTED EXIT SIGN / EMERGENCY LIGHT GENERAL NOTES A. THE PLANS ARE DIAGRAMMATIC IN NATURE AND THEIR INTENT IS TO SHOW THE BASIC REQUIREMENTS OF THE SYSTEM. THE INSTALLER SHALL FURNISH ALL MATERIALS, FIXTURES, WIRING, DEVICES, SUPPORT, DISCONNECT SWITCHES, AND OTHER REQUIRED EQUIPMENT NOT SPECIFICALLY INDICATED HEREIN, AND LABOR FOR A COMPLETE AND OPERATING SYSTEM AS SPECIFIED HEREIN. THE INSTALLER IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ANY NECESSARY PERMITS AND APPROVALS, AND ANY OTHER CHARGES OR FEES. B. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NFPA 70), AND THE THE MASSACHUSETTS ELECTRIC CODE. C. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. WIRING2. A. ALL WIRING SHALL MATCH EXISTING BUILDING STANDARD UNLESS SPECIFICALLY INDICATED OTHERWISE. ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND THE MASSACHUSETTS ELECTRIC CODE. ALL WIRING TO BE RUN CONCEALED. IN MOST CASE NEW LIGHTS SHOWN ARE TO BE CONNECTED TO EXISTING CIRCUITS IN THE AREA. 1. WIRING FOR CIRCUITS INDICATED TO BE CONNECTED TO THE EMERGENCY SYSTEM (IF REQUIRED/SHOWN) SHALL BE KEPT ENTIRELY INDEPENDENT OF OTHER WIRING AND SHALL NOT ENTER THE SAME RACEWAY, BOX, CABINET, ETC. WITH OTHER WIRING. A SEPARATE WIRE AND CONDUIT SYSTEM IS REQUIRED FOR THE EMERGENCY SYSTEM IDENTIFIED AS AN EMERGENCY SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. 3.RECEPTACLES A. ALL DUPLEX AND/OR QUADRUPLEX RECEPTACLES TO BE MOUNTED 18" ABOVE FINISH FLOOR UNLESS INDICATED OTHERWISE. RECEPTACLES TO BE COMMERCIAL GRADE RATED FOR 20 AMPS 120V. 4.SWITCHES A. LIGHTING SWITCHES SHALL BE RATED FOR 20 AMP 120/277 VOLTS. B. INSTALL WALL SWITCHES 48 INCHES (ON CENTER) ABOVE FLOOR, OFF POSITION DOWN. 6.SUPPORT REQUIREMENTS A. LIGHT FIXTURES TO BE SUPPORTED INDEPENDENT OF THE CEILING GRID SYSTEM. THEY SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE WITH JACK CHAINS. 8.FIRESTOPPING A. THE INTEGRITY OF FIRE-RATED WALLS AND FLOORS, WHERE PENETRATIONS ARE MADE FOR THE PASSAGE OF CONDUIT, CABLES, ETC., MUST BE MAINTAINED. 1. ALL PENETRATIONS MUST BE SLEEVED AND FIRE STOPPED WITH MATERIALS THAT ARE UL CLASSIFIED AND FACTORY MUTUAL APPROVED FOR USE IN APPLICABLE RATED ASSEMBLY. 9.PANEL BALANCING A. THE ELECTRICAL CONTRACTOR SHALL BALANCE ALL CIRCUITS AS REQUIRED AT ALL PANELS. 5 DATA / TELEPHONE OUTLET A. ALL DATA / TELEPHONE OUTLETS TO CONSIST OF FLUSH OUTLET BOX WITH CONCEALED 3/4" METAL CONDUIT RUN TO ABOVE SUSPENDED CEILING. B. TELEPHONE / DATA WIRING TO BE ACCOMPLISHED BY OWNERS CONTRACTOR. D. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF EQUIPMENT. ITEMS WHICH ARE NOT SPECIFICALLY LOCATED BY DIMENSION ON THE ARCHITECTURAL PLANS SHOULD BE COORDINATED WITH THE ARCHITECT. E. ALL EQUIPMENT LISTED ON THE DRAWING IS SPECIFIED AS "OR APPROVED EQUAL" UNLESS INDICATED OTHERWISE. THE CONTRACTOR SHALL PROVIDE SUBMITTALS FOR ANY EQUIPMENT DIFFERENT FROM WHAT IS LISTED ON THE DRAWINGS FOR APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION. FOR GENERAL EQUIPMENT WHICH IS NOT LISTED ON THE DRAWINGS, SUBMITTALS ARE REQUIRED. F. FOR EQUIPMENT FURNISHED BY "OTHERS", THE ELECTRICAL CONTRACTOR SHALL RUN THE POWER LINES TO EQUIPMENT DISCONNECT SWITCHES AND MAKE FINAL CONNECTION TO EQUIPMENT UNLESS INDICATED OTHERWISE. THE CONTROLS FOR SAID EQUIPMENT SHALL BE THE RESPONSIBILITY OF "OTHERS" UNLESS NOTED OTHERWISE. COORDINATE LOADS WITH OTHER TRADES AND VERIFY SAME. G.CONTRACTOR TO COORDINATE I.T. REQUIREMENTS WITH OWNER. MARKINGS A. MARK EXTERIOR OF ALL JUNCTION BOXES IN THE ELECTRICAL WIRING SYSTEM TO INDICATE CIRCUIT NUMBER AND PANEL DESIGNATION OF ALL CIRCUITS. 7. 18" 18" P F 3" RECESSED LED LIGHTING FIXTURE 1" RECESSED LED LIGHTING FIXTURE LIGHT FIXTURE FIRE ALARM STROBEF 1. BIDS SHALL BE BASED ON THE LIGHTING FIXTURE SCHEDULE AND SPECIFICATIONS. 2. ALL FIXTURES SHALL BE UL LISTED. 3. HIGH FREQUENCY, ELECTRONIC TYPE BALLAST SHALL BE USED WITH ALL FLUORESCENT LAMPS WHEN POSSIBLE. ALL FLUORESCENT BALLAST SHALL HAVE A MIN. POWER FACTOR OF 0.9. A CLASS "A" RATING WHERE POSSIBLE, BE UL LISTED AND BE ON THE NORTHEAST UTILITIES LIST OF APPROVED BALLASTS. FLUORESCENT BALLAST USED IN EXTERIOR FIXTURES SHALL HAVE A MIN. 67$57,1*7(03(5$785(2)q) 4. ALL INCANDESCENT LAMPS DESIGNED FOR 120V OPERATION SHALL BE EXTENDED SERVICE LIFE TIME. 5. ALL NECESSARY MOUNTING HARDWARE, HANGERS, BRACKETS, RAILS, YOKES, STEMS, CHAINS, ETC., SHALL BE FURNISHED AND INSTALLED. 6. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFIC DETAILS, ARRANGEMENT, MOUNTING HEIGHTS, CEILING CONSTRUCTIONS, ETC. ALL COLORS AND FINISHES SHALL BE VERIFIED BY THE ARCHITECT. 7. FIXTURES SHALL BE SEISMICALLY SUPPORTED AS REQUIRED BY THE COMMONWEALTH OF MASSACHUSETTS BUILDING CODE. 8. WIRE ALL BATTERY PACK UNITS (I.E. EXIT SIGNS AND EMERGENCY UNITS) TO LINE SIDE OF LOCAL LIGHTING BRANCH CIRCUIT. LIGHTING FIXTURE NOTES FIRE ALARM SMOKE DETECTOR FIRE ALARM HEAT DETECTOR F S HF ELECTRICAL FIXTURE SCHEDULE A TYPE B C D F 24"X48" RECESSED LED FIXTURE, EXISTING BUILDING STANDARD 24"X24" RECESSED LED FIXTURE, LITHONIA MODEL 2VTL2-33L-ADP-D36-LP850, 120V; 20 GAUGE STEEL HOUSING, SINGLE CLEAR ACRYLIC DIFFUSER; INTEGRAL LED DRIVER 3" RECESSED LED DOWNLIGHT, CREATIVE LIGHTING SYSTEMS MODEL EDL-NC_15W_LPD_1116; INTEGRAL LED DRIVER NOT USED 2' LED UNDERCABINET LIGHT FIXTURE, STEEL HOUSING, ACRYLIC DIFFUSER; WHITE HOUSING, 120 V G 2 HEADED COMBINATION EMERGENCY / EXIT SIGN CONNECTED TO UNSWITCHED CIRCUIT FEEDING ADJACENT LIGHTS.H EXIT LIGHT - TO MATCH BUILDING STANDARD (SINGLE FACE 120V). PROVIDE SEPARATE CIRCUIT FOR EXIT LIGHTS ETR - EXISTING TO REMAIN VIF - VERIFY IN FIELD RL -RELOCATE EXISTING DEVICE NL -NEW LOCATION FOR EXISTING DEVICE WAITING 102 218 SF CONFERENCE ROOM 109 214 SF FILES/ STORAGE 110 115 SF ATTORNEY OFFICE 104 153 SF ADMIN OFFICE 103 103 SF ENTRANCE VESTIBULE 101 42 SF COPY AREA 105 82 SF HALL 106 83 SF E.P.STAFF BREAK 107 53 SF TOILET 108 51 SF P P F F F F S F S ALTERNATE NO. 2: UNDER ALTERNATE NO. 2, DELETE NEW CASEWORK IN COPY AREA #105 (NEW CASEWORK BY OWNER); SEE SHEET A101 AND OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. DELETE TWO (2) UNDER-CABINET LIGHTS AND PLASTIC LAMINATE SOFFIT ABOVE CASEWORK, AND EXTEND SUSPENDED ACOUSTICAL CEILING SYSTEM TO PARTITION. BASE BID: LIGHTING AS SHOWN; UNDER ALTERNATE NO. 3, DELETE ELEVEN (11) RECESSED LED FIXTURES IN CONFERENCE ROOM #109, AND INSTALL SIX (6) NEW 2X2 LED RECESSED TROFFERS; SEE DETAIL 19/A102 BELOW. B B ETR ETR A (NL) B B B B B BB BBB B B B BB B B C C C C CCC C C C C C C C C A (NL)A (NL) H H H (NL) FF SIM ETR ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0" WAITING 102 CONFERENCE ROOM 109 FILES/ STORAGE 110 ATTORNEY OFFICE 104 ADMIN OFFICE 103 ENTRANCE VESTIBULE 101 COAT RACK REF.(U.C.)MICROTV COPY AREA 105 HALL 106 E.P.STAFF BREAK 107 TOILET 108 P P F F F ELECTRICAL DEVICE PLAN SCALE: 1/4" = 1'-0" 18" 18" 18" 18" 18" 18" ETR V.I.F.COORDINATE REQUIRED OUTLET TYPES ANDMOUNTING HEIGHT FOR T.V. WITH OWNER. ENSURE T.V. SCREEN HIDES ALL OUTLETS.18"DEDICATED 44"18"18"18" 18" 18" V.I.F.18"18" V.I.F. 18"44"3 3 UNDER- CABINET LIGHTS (SWITCH INTEGRATED WITH FIXTURE) 3 3 18" 18"ETRETRETR ETR ETR (44" GFCI) RELOCATED PULL STATION AT NEW EGRESS DOOR; COMPLY WITH NFPA 101: LIFE SAFETY CODERELOCATED COMBINATION EMERGENCY LIGHT AND EXIT SIGN AT NEW EGRESS DOOR; COMPLY WITH NFPA 101: LIFE SAFETY CODE F S F S ETR ETR F S NL F S NL CONFERENCE ROOM 109 214 SF B B B B B B ELECTRICAL LIGHTING PLAN - ALTERNATE NO. 3 SCALE: 1/4" = 1'-0" ALTERNATE NO. 3: UNDER ALTERNATE NO. 3, DELETE ELEVEN (11) RECESSED LED FIXTURES IN CONFERENCE ROOM #109, AND INSTALL SIX (6) NEW 2X2 LED RECESSED TROFFERS AS SHOWN ON SHEET A102: REFLECTED CEILING PLAN AND SHEET E101: ELECTRICAL POWER AND LIGHTING PLAN; SEE OTHER SHEETS AS MAY REFERENCE THE SCOPE OF WORK. REMOVE EXISTING PULL STATION AND RELOCATE TO NEW EGRESS DOOR REMOVE COMBINATION EMERGENCY LIGHT AND EXIT SIGN AND RELOCATE TO NEW EGRESS DOOR COORDINATE REQUIRED OUTLET TYPES ANDMOUNTING HEIGHT FOR T.V. WITH OWNER. ENSURE T.V. SCREEN HIDES ALL OUTLETS. 44" GFCI ETR ETR GFCIREMOVE WALL SWITCH AND PROVIDE BLANK PLATE TO MATCH BLDG STANDARD REWORK EXISTING ELEC OUTLET TO MAKE GFCI COMPLAINT48"48" ELECTRICAL LIGHTING PLAN & ELECTRICAL DEVICE PLAN E101 BW SEAL: MARK DATE ISSUE -05/04/2017 PERMIT SET PROJECT NO: PROJECT ARCHITECT: PROJECT MANAGER: DRAWN BY: DATE: COPYRIGHT: 16-095 DJH DJH 04/21/2017 SHEET TITLE: CONSULTANT: 64 GOTHIC STREET, SUITE 1 NORTHAMPTON, MA 01060 T 413.585.1512 F 413.586.7945 www.haiarchitecture.com H AI Architecture, Inc. Corliss Law Office 100 Main Street Florence, MA 01062 Renovation for: PROJECT:5/4/2017 4:52 PM